forked from vitalif/vitastor
Compare commits
2 Commits
master
...
nfs-proxy-
Author | SHA1 | Date |
---|---|---|
Vitaliy Filippov | 6261809e87 | |
Vitaliy Filippov | d7e64e6ea1 |
|
@ -4,3 +4,6 @@
|
|||
[submodule "json11"]
|
||||
path = json11
|
||||
url = ../json11.git
|
||||
[submodule "libnfs"]
|
||||
path = libnfs
|
||||
url = ../libnfs.git
|
||||
|
|
|
@ -2,6 +2,6 @@ cmake_minimum_required(VERSION 2.8)
|
|||
|
||||
project(vitastor)
|
||||
|
||||
set(VERSION "0.6.17")
|
||||
set(VERSION "0.6.16")
|
||||
|
||||
add_subdirectory(src)
|
||||
|
|
667
README-ru.md
667
README-ru.md
|
@ -4,68 +4,635 @@
|
|||
|
||||
## Идея
|
||||
|
||||
Вернём былую скорость кластерному блочному хранилищу!
|
||||
Я всего лишь хочу сделать качественную блочную SDS!
|
||||
|
||||
Vitastor - распределённая блочная SDS (программная СХД), прямой аналог Ceph RBD и
|
||||
внутренних СХД популярных облачных провайдеров. Однако, в отличие от них, Vitastor
|
||||
быстрый и при этом простой. Только пока маленький :-).
|
||||
Vitastor - распределённая блочная SDS, прямой аналог Ceph RBD и внутренних СХД популярных
|
||||
облачных провайдеров. Однако, в отличие от них, Vitastor быстрый и при этом простой.
|
||||
Только пока маленький :-).
|
||||
|
||||
Vitastor архитектурно похож на Ceph, что означает атомарность и строгую консистентность,
|
||||
Архитектурная схожесть с Ceph означает заложенную на уровне алгоритмов записи строгую консистентность,
|
||||
репликацию через первичный OSD, симметричную кластеризацию без единой точки отказа
|
||||
и автоматическое распределение данных по любому числу дисков любого размера с настраиваемыми схемами
|
||||
избыточности - репликацией или с произвольными кодами коррекции ошибок.
|
||||
|
||||
Vitastor нацелен на SSD и SSD+HDD кластеры с как минимум 10 Гбит/с сетью, поддерживает
|
||||
TCP и RDMA и на хорошем железе может достигать задержки 4 КБ чтения и записи на уровне ~0.1 мс,
|
||||
что примерно в 10 раз быстрее, чем Ceph и другие популярные программные СХД.
|
||||
## Возможности
|
||||
|
||||
Vitastor поддерживает QEMU-драйвер, протоколы NBD и NFS, драйверы OpenStack, Proxmox, Kubernetes.
|
||||
Другие драйверы могут также быть легко реализованы.
|
||||
Vitastor на данный момент находится в статусе предварительного выпуска, расширенные
|
||||
возможности пока отсутствуют, а в будущих версиях вероятны "ломающие" изменения.
|
||||
|
||||
Подробности смотрите в документации по ссылкам ниже.
|
||||
Однако следующее уже реализовано:
|
||||
|
||||
## Презентации и записи докладов
|
||||
- Базовая часть - надёжное кластерное блочное хранилище без единой точки отказа
|
||||
- Производительность ;-D
|
||||
- Несколько схем отказоустойчивости: репликация, XOR n+1 (1 диск чётности), коды коррекции ошибок
|
||||
Рида-Соломона на основе библиотеки jerasure с любым числом дисков данных и чётности в группе
|
||||
- Конфигурация через простые человекочитаемые JSON-структуры в etcd
|
||||
- Автоматическое распределение данных по OSD, с поддержкой:
|
||||
- Математической оптимизации для лучшей равномерности распределения и минимизации перемещений данных
|
||||
- Нескольких пулов с разными схемами избыточности
|
||||
- Дерева распределения, выбора OSD по тегам / классам устройств (только SSD, только HDD) и по поддереву
|
||||
- Настраиваемых доменов отказа (диск/сервер/стойка и т.п.)
|
||||
- Восстановление деградированных блоков
|
||||
- Ребаланс, то есть перемещение данных между OSD (дисками)
|
||||
- Поддержка "ленивого" fsync (fsync не на каждую операцию)
|
||||
- Сбор статистики ввода/вывода в etcd
|
||||
- Клиентская библиотека режима пользователя для ввода/вывода
|
||||
- Драйвер диска для QEMU (собирается вне дерева исходников QEMU)
|
||||
- Драйвер диска для утилиты тестирования производительности fio (также собирается вне дерева исходников fio)
|
||||
- NBD-прокси для монтирования образов ядром ("блочное устройство в режиме пользователя")
|
||||
- Утилита для удаления образов/инодов (vitastor-cli rm-data)
|
||||
- Пакеты для Debian и CentOS
|
||||
- Статистика операций ввода/вывода и занятого места в разрезе инодов
|
||||
- Именование инодов через хранение их метаданных в etcd
|
||||
- Снапшоты и copy-on-write клоны
|
||||
- Сглаживание производительности случайной записи в SSD+HDD конфигурациях
|
||||
- Поддержка RDMA/RoCEv2 через libibverbs
|
||||
- CSI-плагин для Kubernetes
|
||||
- Базовая поддержка OpenStack: драйвер Cinder, патчи для Nova и libvirt
|
||||
- Слияние снапшотов (vitastor-cli {snap-rm,flatten,merge})
|
||||
- Консольный интерфейс для управления образами (vitastor-cli {ls,create,modify})
|
||||
- Плагин для Proxmox
|
||||
|
||||
- DevOpsConf'2021: презентация ([на русском](https://vitastor.io/presentation/devopsconf/devopsconf.html),
|
||||
[на английском](https://vitastor.io/presentation/devopsconf/devopsconf_en.html)),
|
||||
[видео](https://vitastor.io/presentation/devopsconf/talk.webm)
|
||||
- Highload'2022: презентация ([на русском](https://vitastor.io/presentation/highload/highload.html)),
|
||||
[видео](https://vitastor.io/presentation/highload/talk.webm)
|
||||
## Планы развития
|
||||
|
||||
## Документация
|
||||
- Более корректные скрипты разметки дисков и автоматического запуска OSD
|
||||
- Другие инструменты администрирования
|
||||
- Плагины для OpenNebula и других облачных систем
|
||||
- iSCSI-прокси
|
||||
- Упрощённый NFS прокси
|
||||
- Более быстрое переключение при отказах
|
||||
- Фоновая проверка целостности без контрольных сумм (сверка реплик)
|
||||
- Контрольные суммы
|
||||
- Поддержка SSD-кэширования (tiered storage)
|
||||
- Поддержка NVDIMM
|
||||
- Web-интерфейс
|
||||
- Возможно, сжатие
|
||||
- Возможно, поддержка кэширования данных через системный page cache
|
||||
|
||||
- Введение
|
||||
- [Быстрый старт](docs/intro/quickstart.ru.md)
|
||||
- [Возможности](docs/intro/features.ru.md)
|
||||
- [Архитектура](docs/intro/architecture.ru.md)
|
||||
- [Автор и лицензия](docs/intro/author.ru.md)
|
||||
- Установка
|
||||
- [Пакеты](docs/installation/packages.ru.md)
|
||||
- [Proxmox](docs/installation/proxmox.ru.md)
|
||||
- [OpenStack](docs/installation/openstack.ru.md)
|
||||
- [Kubernetes CSI](docs/installation/kubernetes.ru.md)
|
||||
- [Сборка из исходных кодов](docs/installation/source.ru.md)
|
||||
- Конфигурация
|
||||
- [Обзор](docs/config.ru.md)
|
||||
- Параметры
|
||||
- [Общие](docs/config/common.ru.md)
|
||||
- [Сетевые](docs/config/network.ru.md)
|
||||
- [Глобальные дисковые параметры](docs/config/layout-cluster.ru.md)
|
||||
- [Дисковые параметры OSD](docs/config/layout-osd.ru.md)
|
||||
- [Прочие параметры OSD](docs/config/osd.ru.md)
|
||||
- [Параметры мониторов](docs/config/monitor.ru.md)
|
||||
- [Настройки пулов](docs/config/pool.ru.md)
|
||||
- [Метаданные образов в etcd](docs/config/inode.ru.md)
|
||||
- Использование
|
||||
- [vitastor-cli](docs/usage/cli.ru.md) (консольный интерфейс)
|
||||
- [fio](docs/usage/fio.ru.md) для тестов производительности
|
||||
- [NBD](docs/usage/nbd.ru.md) для монтирования ядром
|
||||
- [QEMU и qemu-img](docs/usage/qemu.ru.md)
|
||||
- [NFS](docs/usage/nfs.ru.md)-прокси для VMWare и подобных
|
||||
- Производительность
|
||||
- [Понимание сути производительности](docs/performance/understanding.ru.md)
|
||||
- [Теоретический максимум](docs/performance/theoretical.ru.md)
|
||||
- [Пример сравнения с Ceph](docs/performance/comparison1.ru.md)
|
||||
## Архитектура
|
||||
|
||||
Так же, как и в Ceph, в Vitastor:
|
||||
|
||||
- Есть пулы (pools), PG, OSD, мониторы, домены отказа, дерево распределения (аналог crush-дерева).
|
||||
- Образы делятся на блоки фиксированного размера (объекты), и эти объекты распределяются по OSD.
|
||||
- У OSD есть журнал и метаданные и они тоже могут размещаться на отдельных быстрых дисках.
|
||||
- Все операции записи тоже транзакционны. В Vitastor, правда, есть режим отложенного/ленивого fsync
|
||||
(коммита), в котором fsync не вызывается на каждую операцию записи, что делает его более
|
||||
пригодным для использования на "плохих" (десктопных) SSD. Однако все операции записи
|
||||
в любом случае атомарны.
|
||||
- Клиентская библиотека тоже старается ждать восстановления после любого отказа кластера, то есть,
|
||||
вы тоже можете перезагрузить хоть весь кластер разом, и клиенты только на время зависнут,
|
||||
но не отключатся.
|
||||
|
||||
Некоторые базовые термины для тех, кто не знаком с Ceph:
|
||||
|
||||
- OSD (Object Storage Daemon) - процесс, который хранит данные на одном диске и обрабатывает
|
||||
запросы чтения/записи от клиентов.
|
||||
- Пул (Pool) - контейнер для данных, имеющих одну и ту же схему избыточности и правила распределения по OSD.
|
||||
- PG (Placement Group) - группа объектов, хранимых на одном и том же наборе реплик (OSD).
|
||||
Несколько PG могут храниться на одном и том же наборе реплик, но объекты одной PG
|
||||
в норме не хранятся на разных наборах OSD.
|
||||
- Монитор - демон, хранящий состояние кластера.
|
||||
- Домен отказа (Failure Domain) - группа OSD, которым вы разрешаете "упасть" всем вместе.
|
||||
Иными словами, это группа OSD, в которые СХД не помещает разные копии одного и того же
|
||||
блока данных. Например, если домен отказа - сервер, то на двух дисках одного сервера
|
||||
никогда не окажется 2 и более копий одного и того же блока данных, а значит, даже
|
||||
если в этом сервере откажут все диски, это будет равносильно потере только 1 копии
|
||||
любого блока данных.
|
||||
- Дерево распределения (Placement Tree / CRUSH Tree) - иерархическая группировка OSD
|
||||
в узлы, которые далее можно использовать как домены отказа. То есть, диск (OSD) входит в
|
||||
сервер, сервер входит в стойку, стойка входит в ряд, ряд в датацентр и т.п.
|
||||
|
||||
Чем Vitastor отличается от Ceph:
|
||||
|
||||
- Vitastor в первую очередь сфокусирован на SSD. Также Vitastor, вероятно, должен неплохо работать
|
||||
с комбинацией SSD и HDD через bcache, а в будущем, возможно, будут добавлены и нативные способы
|
||||
оптимизации под SSD+HDD. Однако хранилище на основе одних лишь жёстких дисков, вообще без SSD,
|
||||
не в приоритете, поэтому оптимизации под этот кейс могут вообще не состояться.
|
||||
- OSD Vitastor однопоточный и всегда таким останется, так как это самый оптимальный способ работы.
|
||||
Если вам не хватает 1 ядра на 1 диск, просто делите диск на разделы и запускайте на нём несколько OSD.
|
||||
Но, скорее всего, вам хватит и 1 ядра - Vitastor не так прожорлив к ресурсам CPU, как Ceph.
|
||||
- Журнал и метаданные всегда размещаются в памяти, благодаря чему никогда не тратится лишнее время
|
||||
на чтение метаданных с диска. Размер метаданных линейно зависит от размера диска и блока данных,
|
||||
который задаётся в конфигурации кластера и по умолчанию составляет 128 КБ. С блоком 128 КБ метаданные
|
||||
занимают примерно 512 МБ памяти на 1 ТБ дискового пространства (и это всё равно меньше, чем нужно Ceph-у).
|
||||
Журнал вообще не должен быть большим, например, тесты производительности в данном документе проводились
|
||||
с журналом размером всего 16 МБ. Большой журнал, вероятно, даже вреден, т.к. "грязные" записи (записи,
|
||||
не сброшенные из журнала) тоже занимают память и могут немного замедлять работу.
|
||||
- В Vitastor нет внутреннего copy-on-write. Я считаю, что реализация CoW-хранилища гораздо сложнее,
|
||||
поэтому сложнее добиться устойчиво хороших результатов. Возможно, в один прекрасный день
|
||||
я придумаю красивый алгоритм для CoW-хранилища, но пока нет - внутреннего CoW в Vitastor не будет.
|
||||
Всё это не относится к "внешнему" CoW (снапшотам и клонам).
|
||||
- Базовый слой Vitastor - простое блочное хранилище с блоками фиксированного размера, а не сложное
|
||||
объектное хранилище с расширенными возможностями, как в Ceph (RADOS).
|
||||
- В Vitastor есть режим "ленивых fsync", в котором OSD группирует запросы записи перед сбросом их
|
||||
на диск, что позволяет получить лучшую производительность с дешёвыми настольными SSD без конденсаторов
|
||||
("Advanced Power Loss Protection" / "Capacitor-Based Power Loss Protection").
|
||||
Тем не менее, такой режим всё равно медленнее использования нормальных серверных SSD и мгновенного
|
||||
fsync, так как приводит к дополнительным операциям передачи данных по сети, поэтому рекомендуется
|
||||
всё-таки использовать хорошие серверные диски, тем более, стоят они почти так же, как десктопные.
|
||||
- PG эфемерны. Это означает, что они не хранятся на дисках и существуют только в памяти работающих OSD.
|
||||
- Процессы восстановления оперируют отдельными объектами, а не целыми PG.
|
||||
- PGLOG-ов нет.
|
||||
- "Мониторы" не хранят данные. Конфигурация и состояние кластера хранятся в etcd в простых человекочитаемых
|
||||
JSON-структурах. Мониторы Vitastor только следят за состоянием кластера и управляют перемещением данных.
|
||||
В этом смысле монитор Vitastor не является критичным компонентом системы и больше похож на Ceph-овский
|
||||
менеджер (MGR). Монитор Vitastor написан на node.js.
|
||||
- Распределение PG не основано на консистентных хешах. Вместо этого все маппинги PG хранятся прямо в etcd
|
||||
(ибо нет никакой проблемы сохранить несколько сотен-тысяч записей в памяти, а не считать каждый раз хеши).
|
||||
Перераспределение PG по OSD выполняется через математическую оптимизацию,
|
||||
а конкретно, сведение задачи к ЛП (задаче линейного программирования) и решение оной с помощью утилиты
|
||||
lp_solve. Такой подход позволяет обычно выравнивать распределение места почти идеально - равномерность
|
||||
обычно составляет 96-99%, в отличие от Ceph, где на голом CRUSH-е без балансировщика обычно выходит 80-90%.
|
||||
Также это позволяет минимизировать объём перемещения данных и случайность связей между OSD, а также менять
|
||||
распределение вручную, не боясь сломать логику перебалансировки. В таком подходе есть и потенциальный
|
||||
недостаток - есть предположение, что в очень большом кластере он может сломаться - однако вплоть до
|
||||
нескольких сотен OSD подход точно работает нормально. Ну и, собственно, при необходимости легко
|
||||
реализовать и консистентные хеши.
|
||||
- Отдельный слой, подобный слою "CRUSH-правил", отсутствует. Вы настраиваете схемы отказоустойчивости,
|
||||
домены отказа и правила выбора OSD напрямую в конфигурации пулов.
|
||||
|
||||
## Понимание сути производительности систем хранения
|
||||
|
||||
Вкратце: для быстрой хранилки задержки важнее, чем пиковые iops-ы.
|
||||
|
||||
Лучшая возможная задержка достигается при тестировании в 1 поток с глубиной очереди 1,
|
||||
что приблизительно означает минимально нагруженное состояние кластера. В данном случае
|
||||
IOPS = 1/задержка. Ни числом серверов, ни дисков, ни серверных процессов/потоков
|
||||
задержка не масштабируется... Она зависит только от того, насколько быстро один
|
||||
серверный процесс (и клиент) обрабатывают одну операцию.
|
||||
|
||||
Почему задержки важны? Потому, что некоторые приложения *не могут* использовать глубину
|
||||
очереди больше 1, ибо их задача не параллелизуется. Важный пример - это все СУБД
|
||||
с поддержкой консистентности (ACID), потому что все они обеспечивают её через
|
||||
журналирование, а журналы пишутся последовательно и с fsync() после каждой операции.
|
||||
|
||||
fsync, кстати - это ещё одна очень важная вещь, про которую почти всегда забывают в тестах.
|
||||
Смысл в том, что все современные диски имеют кэши/буферы записи и не гарантируют, что
|
||||
данные реально физически записываются на носитель до того, как вы делаете fsync(),
|
||||
который транслируется в команду сброса кэша операционной системой.
|
||||
|
||||
Дешёвые SSD для настольных ПК и ноутбуков очень быстрые без fsync - NVMe диски, например,
|
||||
могут обработать порядка 80000 операций записи в секунду с глубиной очереди 1 без fsync.
|
||||
Однако с fsync, когда они реально вынуждены писать каждый блок данных во флеш-память,
|
||||
они выжимают лишь 1000-2000 операций записи в секунду (число практически постоянное
|
||||
для всех моделей SSD).
|
||||
|
||||
Серверные SSD часто имеют суперконденсаторы, работающие как встроенный источник
|
||||
бесперебойного питания и дающие дискам успеть сбросить их DRAM-кэш в постоянную
|
||||
флеш-память при отключении питания. Благодаря этому диски с чистой совестью
|
||||
*игнорируют fsync*, так как точно знают, что данные из кэша доедут до постоянной
|
||||
памяти.
|
||||
|
||||
Все наиболее известные программные СХД, например, Ceph и внутренние СХД, используемые
|
||||
такими облачными провайдерами, как Amazon, Google, Яндекс, медленные в смысле задержки.
|
||||
В лучшем случае они дают задержки от 0.3мс на чтение и 0.6мс на запись 4 КБ блоками
|
||||
даже при условии использования наилучшего возможного железа.
|
||||
|
||||
И это в эпоху SSD, когда вы можете пойти на рынок и купить там SSD, задержка которого
|
||||
на чтение будет 0.1мс, а на запись - 0.04мс, за 100$ или даже дешевле.
|
||||
|
||||
Когда мне нужно быстро протестировать производительность дисковой подсистемы, я
|
||||
использую следующие 6 команд, с небольшими вариациями:
|
||||
|
||||
- Линейная запись:
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
|
||||
- Линейное чтение:
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
|
||||
- Запись в 1 поток (T1Q1):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Чтение в 1 поток (T1Q1):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
- Параллельная запись (numjobs используется, когда 1 ядро CPU не может насытить диск):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Параллельное чтение (numjobs - аналогично):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
|
||||
## Теоретическая максимальная производительность Vitastor
|
||||
|
||||
При использовании репликации:
|
||||
- Задержка чтения в 1 поток (T1Q1): 1 сетевой RTT + 1 чтение с диска.
|
||||
- Запись+fsync в 1 поток:
|
||||
- С мгновенным сбросом: 2 RTT + 1 запись.
|
||||
- С отложенным ("ленивым") сбросом: 4 RTT + 1 запись + 1 fsync.
|
||||
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
|
||||
- Параллельная запись: сумма IOPS всех дисков / число реплик / WA либо производительность сети, если в сеть упрётся раньше.
|
||||
|
||||
При использовании кодов коррекции ошибок (EC):
|
||||
- Задержка чтения в 1 поток (T1Q1): 1.5 RTT + 1 чтение.
|
||||
- Запись+fsync в 1 поток:
|
||||
- С мгновенным сбросом: 3.5 RTT + 1 чтение + 2 записи.
|
||||
- С отложенным ("ленивым") сбросом: 5.5 RTT + 1 чтение + 2 записи + 2 fsync.
|
||||
- Под 0.5 на самом деле подразумевается (k-1)/k, где k - число дисков данных,
|
||||
что означает, что дополнительное обращение по сети не нужно, когда операция
|
||||
чтения обслуживается локально.
|
||||
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
|
||||
- Параллельная запись: сумма IOPS всех дисков / общее число дисков данных и чётности / WA либо производительность сети, если в сеть упрётся раньше.
|
||||
Примечание: IOPS дисков в данном случае надо брать в смешанном режиме чтения/записи в пропорции, аналогичной формулам выше.
|
||||
|
||||
WA (мультипликатор записи) для 4 КБ блоков в Vitastor обычно составляет 3-5:
|
||||
1. Запись метаданных в журнал
|
||||
2. Запись блока данных в журнал
|
||||
3. Запись метаданных в БД
|
||||
4. Ещё одна запись метаданных в журнал при использовании EC
|
||||
5. Запись блока данных на диск данных
|
||||
|
||||
Если вы найдёте SSD, хорошо работающий с 512-байтными блоками данных (Optane?),
|
||||
то 1, 3 и 4 можно снизить до 512 байт (1/8 от размера данных) и получить WA всего 2.375.
|
||||
|
||||
Кроме того, WA снижается при использовании отложенного/ленивого сброса при параллельной
|
||||
нагрузке, т.к. блоки журнала записываются на диск только когда они заполняются или явным
|
||||
образом запрашивается fsync.
|
||||
|
||||
## Пример сравнения с Ceph
|
||||
|
||||
Железо - 4 сервера, в каждом:
|
||||
- 6x SATA SSD Intel D3-4510 3.84 TB
|
||||
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
|
||||
- 384 GB RAM
|
||||
- 1x 25 GbE сетевая карта (Mellanox ConnectX-4 LX), подключённая к свитчу Juniper QFX5200
|
||||
|
||||
Экономия энергии CPU отключена. В тестах и Vitastor, и Ceph развёрнуто по 2 OSD на 1 SSD.
|
||||
|
||||
Все результаты ниже относятся к случайной нагрузке 4 КБ блоками (если явно не указано обратное).
|
||||
|
||||
Производительность голых дисков:
|
||||
- T1Q1 запись ~27000 iops (задержка ~0.037ms)
|
||||
- T1Q1 чтение ~9800 iops (задержка ~0.101ms)
|
||||
- T1Q32 запись ~60000 iops
|
||||
- T1Q32 чтение ~81700 iops
|
||||
|
||||
Ceph 15.2.4 (Bluestore):
|
||||
- T1Q1 запись ~1000 iops (задержка ~1ms)
|
||||
- T1Q1 чтение ~1750 iops (задержка ~0.57ms)
|
||||
- T8Q64 запись ~100000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
|
||||
- T8Q64 чтение ~480000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
|
||||
|
||||
Тесты в 8 потоков проводились на 8 400GB RBD образах со всех хостов (с каждого хоста запускалось 2 процесса fio).
|
||||
Это нужно потому, что в Ceph несколько RBD-клиентов, пишущих в 1 образ, очень сильно замедляются.
|
||||
|
||||
Настройки RocksDB и Bluestore в Ceph не менялись, единственным изменением было отключение cephx_sign_messages.
|
||||
|
||||
На самом деле, результаты теста не такие уж и плохие для Ceph (могло быть хуже).
|
||||
Собственно говоря, эти серверы как раз хорошо сбалансированы для Ceph - 6 SATA SSD как раз
|
||||
утилизируют 25-гигабитную сеть, а без 2 мощных процессоров Ceph-у бы не хватило ядер,
|
||||
чтобы выдать пристойный результат. Собственно, что и показывает жор 40 ядер в процессе
|
||||
параллельного теста.
|
||||
|
||||
Vitastor:
|
||||
- T1Q1 запись: 7087 iops (задержка 0.14ms)
|
||||
- T1Q1 чтение: 6838 iops (задержка 0.145ms)
|
||||
- T2Q64 запись: 162000 iops, потребление CPU - 3 ядра на каждом сервере
|
||||
- T8Q64 чтение: 895000 iops, потребление CPU - 4 ядра на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 2800 МБ/с
|
||||
- Линейное чтение (4M T1Q32): 1500 МБ/с
|
||||
|
||||
Тест на чтение в 8 потоков проводился на 1 большом образе (3.2 ТБ) со всех хостов (опять же, по 2 fio с каждого).
|
||||
В Vitastor никакой разницы между 1 образом и 8-ю нет. Естественно, примерно 1/4 запросов чтения
|
||||
в такой конфигурации, как и в тестах Ceph выше, обслуживалась с локальной машины. Если проводить
|
||||
тест так, чтобы все операции всегда обращались к первичным OSD по сети - тест сильнее упирался
|
||||
в сеть и результат составлял примерно 689000 iops.
|
||||
|
||||
Настройки Vitastor: `--disable_data_fsync true --immediate_commit all --flusher_count 8
|
||||
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
|
||||
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
|
||||
--journal_size 16777216`.
|
||||
|
||||
### EC/XOR 2+1
|
||||
|
||||
Vitastor:
|
||||
- T1Q1 запись: 2808 iops (задержка ~0.355ms)
|
||||
- T1Q1 чтение: 6190 iops (задержка ~0.16ms)
|
||||
- T2Q64 запись: 85500 iops, потребление CPU - 3.4 ядра на каждом сервере
|
||||
- T8Q64 чтение: 812000 iops, потребление CPU - 4.7 ядра на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 3200 МБ/с
|
||||
- Линейное чтение (4M T1Q32): 1800 МБ/с
|
||||
|
||||
Ceph:
|
||||
- T1Q1 запись: 730 iops (задержка ~1.37ms latency)
|
||||
- T1Q1 чтение: 1500 iops с холодным кэшем метаданных (задержка ~0.66ms), 2300 iops через 2 минуты прогрева (задержка ~0.435ms)
|
||||
- T4Q128 запись (4 RBD images): 45300 iops, потребление CPU - 30 ядер на каждом сервере
|
||||
- T8Q64 чтение (4 RBD images): 278600 iops, потребление CPU - 40 ядер на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 1950 МБ/с в пустой образ, 2500 МБ/с в заполненный образ
|
||||
- Линейное чтение (4M T1Q32): 2400 МБ/с
|
||||
|
||||
### NBD
|
||||
|
||||
NBD расшифровывается как "сетевое блочное устройство", но на самом деле оно также
|
||||
работает просто как аналог FUSE для блочных устройств, то есть, представляет собой
|
||||
"блочное устройство в пространстве пользователя".
|
||||
|
||||
NBD - на данный момент единственный способ монтировать Vitastor ядром Linux.
|
||||
NBD немного снижает производительность, так как приводит к дополнительным копированиям
|
||||
данных между ядром и пространством пользователя. Тем не менее, способ достаточно оптимален,
|
||||
а производительность случайного доступа вообще затрагивается слабо.
|
||||
|
||||
Vitastor с однопоточной NBD прокси на том же стенде:
|
||||
- T1Q1 запись: 6000 iops (задержка 0.166ms)
|
||||
- T1Q1 чтение: 5518 iops (задержка 0.18ms)
|
||||
- T1Q128 запись: 94400 iops
|
||||
- T1Q128 чтение: 103000 iops
|
||||
- Линейная запись (4M T1Q128): 1266 МБ/с (в сравнении с 2800 МБ/с через fio)
|
||||
- Линейное чтение (4M T1Q128): 975 МБ/с (в сравнении с 1500 МБ/с через fio)
|
||||
|
||||
## Установка
|
||||
|
||||
### Debian
|
||||
|
||||
- Добавьте ключ репозитория Vitastor:
|
||||
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
|
||||
- Добавьте репозиторий Vitastor в /etc/apt/sources.list:
|
||||
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
|
||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||
- Для Debian 10 (Buster) также включите репозиторий backports:
|
||||
`deb http://deb.debian.org/debian buster-backports main`
|
||||
- Установите пакеты: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
|
||||
|
||||
### CentOS
|
||||
|
||||
- Добавьте в систему репозиторий Vitastor:
|
||||
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
|
||||
- Включите EPEL: `yum/dnf install epel-release`
|
||||
- Включите дополнительные репозитории CentOS:
|
||||
- CentOS 7: `yum install centos-release-scl`
|
||||
- CentOS 8: `dnf install centos-release-advanced-virtualization`
|
||||
- Включите elrepo-kernel:
|
||||
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
|
||||
- Установите пакеты: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
|
||||
|
||||
### Установка из исходников
|
||||
|
||||
- Установите ядро 5.4 или более новое, для поддержки io_uring. Желательно 5.8 или даже новее,
|
||||
так как в 5.4 есть как минимум 1 известный баг, ведущий к зависанию с io_uring и контроллером HP SmartArray.
|
||||
- Установите liburing 0.4 или более новый и его заголовки.
|
||||
- Установите lp_solve.
|
||||
- Установите etcd, версии не ниже 3.4.15. Более ранние версии работать не будут из-за различных багов,
|
||||
например [#12402](https://github.com/etcd-io/etcd/pull/12402). Также вы можете взять версию 3.4.13 с
|
||||
этим конкретным исправлением из ветки release-3.4 репозитория https://github.com/vitalif/etcd/.
|
||||
- Установите node.js 10 или новее.
|
||||
- Установите gcc и g++ 8.x или новее.
|
||||
- Склонируйте данный репозиторий с подмодулями: `git clone https://yourcmc.ru/git/vitalif/vitastor/`.
|
||||
- Желательно пересобрать QEMU с патчем, который делает необязательным запуск через LD_PRELOAD.
|
||||
См `patches/qemu-*.*-vitastor.patch` - выберите версию, наиболее близкую вашей версии QEMU.
|
||||
- Установите QEMU 3.0 или новее, возьмите исходные коды установленного пакета, начните его пересборку,
|
||||
через некоторое время остановите её и скопируйте следующие заголовки:
|
||||
- `<qemu>/include` → `<vitastor>/qemu/include`
|
||||
- Debian:
|
||||
* Берите qemu из основного репозитория
|
||||
* `<qemu>/b/qemu/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* `<qemu>/b/qemu/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
- CentOS 8:
|
||||
* Берите qemu из репозитория Advanced-Virtualization. Чтобы включить его, запустите
|
||||
`yum install centos-release-advanced-virtualization.noarch` и далее `yum install qemu`
|
||||
* `<qemu>/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* Для QEMU 3.0+: `<qemu>/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
* Для QEMU 2.0+: `<qemu>/qapi-types.h` → `<vitastor>/qemu/b/qemu/qapi-types.h`
|
||||
- `config-host.h` и `qapi` нужны, т.к. в них содержатся автогенерируемые заголовки
|
||||
- Установите fio 3.7 или новее, возьмите исходники пакета и сделайте на них симлинк с `<vitastor>/fio`.
|
||||
- Соберите и установите Vitastor командой `mkdir build && cd build && cmake .. && make -j8 && make install`.
|
||||
Обратите внимание на переменную cmake `QEMU_PLUGINDIR` - под RHEL её нужно установить равной `qemu-kvm`.
|
||||
|
||||
## Запуск
|
||||
|
||||
Внимание: процедура пока что достаточно нетривиальная, задавать конфигурацию и смещения
|
||||
на диске нужно почти вручную. Это будет исправлено в ближайшем будущем.
|
||||
|
||||
- Желательны SATA SSD или NVMe диски с конденсаторами (серверные SSD). Можно использовать и
|
||||
десктопные SSD, включив режим отложенного fsync, но производительность однопоточной записи
|
||||
в этом случае пострадает.
|
||||
- Быстрая сеть, минимум 10 гбит/с
|
||||
- Для наилучшей производительности нужно отключить энергосбережение CPU: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||
- На хостах мониторов:
|
||||
- Пропишите нужные вам значения в файле `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Создайте юниты systemd для etcd и мониторов: `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Запустите etcd и мониторы: `systemctl start etcd vitastor-mon`
|
||||
- Пропишите etcd_address и osd_network в `/etc/vitastor/vitastor.conf`. Например:
|
||||
```
|
||||
{
|
||||
"etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"],
|
||||
"osd_network": "10.200.1.0/24"
|
||||
}
|
||||
```
|
||||
- Инициализуйте OSD:
|
||||
- SSD: `/usr/lib/vitastor/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`
|
||||
- Гибридные, HDD+SSD: `/usr/lib/vitastor/mon/make-osd-hybrid.js /dev/sda /dev/sdb ...` - передайте
|
||||
все ваши SSD и HDD скрипту в командной строке подряд, скрипт автоматически выделит разделы под
|
||||
журналы на SSD и данные на HDD. Скрипт пропускает HDD, на которых уже есть разделы
|
||||
или вообще какие-то данные, поэтому если диски непустые, сначала очистите их с помощью
|
||||
`wipefs -a`. SSD с таблицей разделов не пропускаются, но так как скрипт создаёт новые разделы
|
||||
для журналов, на SSD должно быть доступно свободное нераспределённое место.
|
||||
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Смысл некоторых параметров:
|
||||
- `disable_data_fsync 1` - отключает fsync, используется с SSD с конденсаторами.
|
||||
- `immediate_commit all` - используется с SSD с конденсаторами.
|
||||
Внимание: если установлено, также нужно установить его в то же значение в etcd в /vitastor/config/global
|
||||
- `disable_device_lock 1` - отключает блокировку файла устройства, нужно, только если вы запускаете
|
||||
несколько OSD на одном блочном устройстве.
|
||||
- `flusher_count 256` - "flusher" - микропоток, удаляющий старые данные из журнала.
|
||||
Не волнуйтесь об этой настройке, 256 теперь достаточно практически всегда.
|
||||
- `disk_alignment`, `journal_block_size`, `meta_block_size` следует установить равными размеру
|
||||
внутреннего блока SSD. Это почти всегда 4096.
|
||||
- `journal_no_same_sector_overwrites true` запрещает перезапись одного и того же сектора журнала подряд
|
||||
много раз в процессе записи. Большинство (99%) SSD не нуждаются в данной опции. Однако выяснилось, что
|
||||
диски, используемые на одном из тестовых стендов - Intel D3-S4510 - очень сильно не любят такую
|
||||
перезапись, и для них была добавлена эта опция. Когда данный режим включён, также нужно поднимать
|
||||
значение `journal_sector_buffer_count`, так как иначе Vitastor не хватит буферов для записи в журнал.
|
||||
- Создайте глобальную конфигурацию в etcd: `etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||
(если все ваши диски - серверные с конденсаторами).
|
||||
- Создайте пулы: `etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool","scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'`.
|
||||
Для jerasure EC-пулов конфигурация должна выглядеть так: `2:{"name":"ecpool","scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`.
|
||||
- Запустите все OSD: `systemctl start vitastor.target`
|
||||
- Ваш кластер должен быть готов - один из мониторов должен уже сконфигурировать PG, а OSD должны запустить их.
|
||||
- Вы можете проверить состояние PG прямо в etcd: `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. Все PG должны быть 'active'.
|
||||
|
||||
### Задать имя образу
|
||||
|
||||
```
|
||||
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
|
||||
```
|
||||
|
||||
Например:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
|
||||
```
|
||||
|
||||
Если вы зададите parent_id, то образ станет CoW-клоном, т.е. все новые запросы записи пойдут в новый инод, а запросы
|
||||
чтения будут проверять сначала его, а потом родительские слои по цепочке вверх. Чтобы случайно не перезаписать данные
|
||||
в родительском слое, вы можете переключить его в режим "только чтение", добавив флаг `"readonly":true` в его запись
|
||||
метаданных. В таком случае родительский образ становится просто снапшотом.
|
||||
|
||||
Таким образом, для создания снапшота вам нужно просто переименовать предыдущий inode (например, из testimg в testimg@0),
|
||||
сделать его readonly и создать новый слой с исходным именем образа (testimg), ссылающийся на только что переименованный
|
||||
в качестве родительского.
|
||||
|
||||
### Запуск тестов с fio
|
||||
|
||||
Пример команды для запуска тестов:
|
||||
|
||||
```
|
||||
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
|
||||
```
|
||||
|
||||
Если вы не хотите обращаться к образу по имени, вместо `-image=testimg` можно указать номер пула, номер инода и размер:
|
||||
`-pool=1 -inode=1 -size=400G`.
|
||||
|
||||
### Загрузить образ диска ВМ в/из Vitastor
|
||||
|
||||
Используйте qemu-img и строку `vitastor:etcd_host=<HOST>:image=<IMAGE>` в качестве имени файла диска. Например:
|
||||
|
||||
```
|
||||
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg'
|
||||
```
|
||||
|
||||
Обратите внимание, что если вы используете немодифицированный QEMU, потребуется установить переменную окружения
|
||||
`LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so`.
|
||||
|
||||
Если вы не хотите обращаться к образу по имени, вместо `:image=<IMAGE>` можно указать номер пула, номер инода и размер:
|
||||
`:pool=<POOL>:inode=<INODE>:size=<SIZE>`.
|
||||
|
||||
### Запустить ВМ
|
||||
|
||||
Для запуска QEMU используйте опцию `-drive file=vitastor:etcd_host=<HOST>:image=<IMAGE>` (аналогично qemu-img)
|
||||
и физический размер блока 4 KB.
|
||||
|
||||
Например:
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024
|
||||
-drive 'file=vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg',format=raw,if=none,id=drive-virtio-disk0,cache=none
|
||||
-device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1,write-cache=off,physical_block_size=4096,logical_block_size=512
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
Обращение по номерам (`:pool=<POOL>:inode=<INODE>:size=<SIZE>` вместо `:image=<IMAGE>`) работает аналогично qemu-img.
|
||||
|
||||
### Удалить образ
|
||||
|
||||
Используйте утилиту vitastor-cli rm-data. Например:
|
||||
|
||||
```
|
||||
vitastor-cli rm-data --etcd_address 10.115.0.10:2379/v3 --pool 1 --inode 1 --parallel_osds 16 --iodepth 32
|
||||
```
|
||||
|
||||
### NBD
|
||||
|
||||
Чтобы создать локальное блочное устройство, используйте NBD. Например:
|
||||
|
||||
```
|
||||
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
|
||||
```
|
||||
|
||||
Команда напечатает название устройства вида /dev/nbd0, которое потом можно будет форматировать
|
||||
и использовать как обычное блочное устройство.
|
||||
|
||||
Для обращения по номеру инода, аналогично другим командам, можно использовать опции
|
||||
`--pool <POOL> --inode <INODE> --size <SIZE>` вместо `--image testimg`.
|
||||
|
||||
### Kubernetes
|
||||
|
||||
У Vitastor есть CSI-плагин для Kubernetes, поддерживающий RWO-тома.
|
||||
|
||||
Для установки возьмите манифесты из директории [csi/deploy/](csi/deploy/), поместите
|
||||
вашу конфигурацию подключения к Vitastor в [csi/deploy/001-csi-config-map.yaml](001-csi-config-map.yaml),
|
||||
настройте StorageClass в [csi/deploy/009-storage-class.yaml](009-storage-class.yaml)
|
||||
и примените все `NNN-*.yaml` к вашей инсталляции Kubernetes.
|
||||
|
||||
```
|
||||
for i in ./???-*.yaml; do kubectl apply -f $i; done
|
||||
```
|
||||
|
||||
После этого вы сможете создавать PersistentVolume. Пример смотрите в файле [csi/deploy/example-pvc.yaml](csi/deploy/example-pvc.yaml).
|
||||
|
||||
### OpenStack
|
||||
|
||||
Чтобы подключить Vitastor к OpenStack:
|
||||
|
||||
- Установите пакеты vitastor-client, libvirt и QEMU из DEB или RPM репозитория Vitastor
|
||||
- Примените патч `patches/nova-21.diff` или `patches/nova-23.diff` к вашей инсталляции Nova.
|
||||
nova-21.diff подходит для Nova 21-22, nova-23.diff подходит для Nova 23-24.
|
||||
- Скопируйте `patches/cinder-vitastor.py` в инсталляцию Cinder как `cinder/volume/drivers/vitastor.py`
|
||||
- Создайте тип томов в cinder.conf (см. ниже)
|
||||
- Обязательно заблокируйте доступ от виртуальных машин к сети Vitastor (OSD и etcd), т.к. Vitastor (пока) не поддерживает аутентификацию
|
||||
- Перезапустите Cinder и Nova
|
||||
|
||||
Пример конфигурации Cinder:
|
||||
|
||||
```
|
||||
[DEFAULT]
|
||||
enabled_backends = lvmdriver-1, vitastor-testcluster
|
||||
# ...
|
||||
|
||||
[vitastor-testcluster]
|
||||
volume_driver = cinder.volume.drivers.vitastor.VitastorDriver
|
||||
volume_backend_name = vitastor-testcluster
|
||||
image_volume_cache_enabled = True
|
||||
volume_clear = none
|
||||
vitastor_etcd_address = 192.168.7.2:2379
|
||||
vitastor_etcd_prefix =
|
||||
vitastor_config_path = /etc/vitastor/vitastor.conf
|
||||
vitastor_pool_id = 1
|
||||
image_upload_use_cinder_backend = True
|
||||
```
|
||||
|
||||
Чтобы помещать в Vitastor Glance-образы, нужно использовать
|
||||
[https://docs.openstack.org/cinder/pike/admin/blockstorage-volume-backed-image.html](образы на основе томов Cinder),
|
||||
однако, поддержка этой функции ещё не проверялась.
|
||||
|
||||
### Proxmox
|
||||
|
||||
Чтобы подключить Vitastor к Proxmox Virtual Environment (поддерживаются версии 6.4 и 7.1):
|
||||
|
||||
- Добавьте соответствующий Debian-репозиторий Vitastor в sources.list на хостах Proxmox
|
||||
(buster для 6.4, bullseye для 7.1)
|
||||
- Установите пакеты vitastor-client, pve-qemu-kvm, pve-storage-vitastor (* или см. сноску) из репозитория Vitastor
|
||||
- Определите тип хранилища в `/etc/pve/storage.cfg` (см. ниже)
|
||||
- Обязательно заблокируйте доступ от виртуальных машин к сети Vitastor (OSD и etcd), т.к. Vitastor (пока) не поддерживает аутентификацию
|
||||
- Перезапустите демон Proxmox: `systemctl restart pvedaemon`
|
||||
|
||||
Пример `/etc/pve/storage.cfg` (единственная обязательная опция - vitastor_pool, все остальные
|
||||
перечислены внизу для понимания значений по умолчанию):
|
||||
|
||||
```
|
||||
vitastor: vitastor
|
||||
# Пул, в который будут помещаться образы дисков
|
||||
vitastor_pool testpool
|
||||
# Путь к файлу конфигурации
|
||||
vitastor_config_path /etc/vitastor/vitastor.conf
|
||||
# Адрес(а) etcd, нужны, только если не указаны в vitastor.conf
|
||||
vitastor_etcd_address 192.168.7.2:2379/v3
|
||||
# Префикс ключей метаданных в etcd
|
||||
vitastor_etcd_prefix /vitastor
|
||||
# Префикс имён образов
|
||||
vitastor_prefix pve/
|
||||
# Монтировать образы через NBD прокси, через ядро (нужно только для контейнеров)
|
||||
vitastor_nbd 0
|
||||
```
|
||||
|
||||
\* Примечание: вместо установки пакета pve-storage-vitastor вы можете вручную скопировать файл
|
||||
[patches/PVE_VitastorPlugin.pm](patches/PVE_VitastorPlugin.pm) на хосты Proxmox как
|
||||
`/usr/share/perl5/PVE/Storage/Custom/VitastorPlugin.pm`.
|
||||
|
||||
## Известные проблемы
|
||||
|
||||
- Запросы удаления объектов могут в данный момент приводить к "неполным" объектам в EC-пулах,
|
||||
если в процессе удаления произойдут отказы OSD или серверов, потому что правильная обработка
|
||||
запросов удаления в кластере должна быть "трёхфазной", а это пока не реализовано. Если вы
|
||||
столкнётесь с такой ситуацией, просто повторите запрос удаления.
|
||||
|
||||
## Принципы реализации
|
||||
|
||||
- Я люблю архитектурно простые решения. Vitastor проектируется именно так и я намерен
|
||||
и далее следовать данному принципу.
|
||||
- Если вы пришли сюда за идеальным кодом на C++, вы, вероятно, не по адресу. "Общепринятые"
|
||||
практики написания C++ кода меня не очень волнуют, так как зачастую, опять-таки, ведут к
|
||||
излишним усложнениям и код получается красивый... но медленный.
|
||||
- По той же причине в коде иногда можно встретить велосипеды типа собственного упрощённого
|
||||
HTTP-клиента для работы с etcd. Зато эти велосипеды маленькие и компактные и не требуют
|
||||
использования десятка внешних библиотек.
|
||||
- node.js для монитора - не случайный выбор. Он очень быстрый, имеет встроенную событийную
|
||||
машину, приятный нейтральный C-подобный язык программирования и развитую инфраструктуру.
|
||||
|
||||
## Автор и лицензия
|
||||
|
||||
|
|
623
README.md
623
README.md
|
@ -1,71 +1,586 @@
|
|||
# Vitastor
|
||||
## Vitastor
|
||||
|
||||
[Читать на русском](README-ru.md)
|
||||
|
||||
## The Idea
|
||||
|
||||
Make Clustered Block Storage Fast Again.
|
||||
Make Software-Defined Block Storage Great Again.
|
||||
|
||||
Vitastor is a distributed block SDS, direct replacement of Ceph RBD and internal SDS's
|
||||
of public clouds. However, in contrast to them, Vitastor is fast and simple at the same time.
|
||||
The only thing is it's slightly young :-).
|
||||
Vitastor is a small, simple and fast clustered block storage (storage for VM drives),
|
||||
architecturally similar to Ceph which means strong consistency, primary-replication, symmetric
|
||||
clustering and automatic data distribution over any number of drives of any size
|
||||
with configurable redundancy (replication or erasure codes/XOR).
|
||||
|
||||
Vitastor is architecturally similar to Ceph which means strong consistency,
|
||||
primary-replication, symmetric clustering and automatic data distribution over any
|
||||
number of drives of any size with configurable redundancy (replication or erasure codes/XOR).
|
||||
## Features
|
||||
|
||||
Vitastor targets SSD and SSD+HDD clusters with at least 10 Gbit/s network, supports
|
||||
TCP and RDMA and may achieve 4 KB read and write latency as low as ~0.1 ms
|
||||
with proper hardware which is ~10 times faster than other popular SDS's like Ceph
|
||||
or internal systems of public clouds.
|
||||
Vitastor is currently a pre-release, a lot of features are missing and you can still expect
|
||||
breaking changes in the future. However, the following is implemented:
|
||||
|
||||
Vitastor supports QEMU, NBD, NFS protocols, OpenStack, Proxmox, Kubernetes drivers.
|
||||
More drivers may be created easily.
|
||||
- Basic part: highly-available block storage with symmetric clustering and no SPOF
|
||||
- Performance ;-D
|
||||
- Multiple redundancy schemes: Replication, XOR n+1, Reed-Solomon erasure codes
|
||||
based on jerasure library with any number of data and parity drives in a group
|
||||
- Configuration via simple JSON data structures in etcd
|
||||
- Automatic data distribution over OSDs, with support for:
|
||||
- Mathematical optimization for better uniformity and less data movement
|
||||
- Multiple pools
|
||||
- Placement tree, OSD selection by tags (device classes) and placement root
|
||||
- Configurable failure domains
|
||||
- Recovery of degraded blocks
|
||||
- Rebalancing (data movement between OSDs)
|
||||
- Lazy fsync support
|
||||
- I/O statistics reporting to etcd
|
||||
- Generic user-space client library
|
||||
- QEMU driver (built out-of-tree)
|
||||
- Loadable fio engine for benchmarks (also built out-of-tree)
|
||||
- NBD proxy for kernel mounts
|
||||
- Inode removal tool (vitastor-cli rm-data)
|
||||
- Packaging for Debian and CentOS
|
||||
- Per-inode I/O and space usage statistics
|
||||
- Inode metadata storage in etcd
|
||||
- Snapshots and copy-on-write image clones
|
||||
- Write throttling to smooth random write workloads in SSD+HDD configurations
|
||||
- RDMA/RoCEv2 support via libibverbs
|
||||
- CSI plugin for Kubernetes
|
||||
- Basic OpenStack support: Cinder driver, Nova and libvirt patches
|
||||
- Snapshot merge tool (vitastor-cli {snap-rm,flatten,merge})
|
||||
- Image management CLI (vitastor-cli {ls,create,modify})
|
||||
- Proxmox storage plugin
|
||||
|
||||
Read more details below in the documentation.
|
||||
## Roadmap
|
||||
|
||||
## Talks and presentations
|
||||
- Better OSD creation and auto-start tools
|
||||
- Other administrative tools
|
||||
- Plugins for OpenNebula and other cloud systems
|
||||
- iSCSI proxy
|
||||
- Simplified NFS proxy
|
||||
- Faster failover
|
||||
- Scrubbing without checksums (verification of replicas)
|
||||
- Checksums
|
||||
- Tiered storage
|
||||
- NVDIMM support
|
||||
- Web GUI
|
||||
- Compression (possibly)
|
||||
- Read caching using system page cache (possibly)
|
||||
|
||||
- DevOpsConf'2021: presentation ([in Russian](https://vitastor.io/presentation/devopsconf/devopsconf.html),
|
||||
[in English](https://vitastor.io/presentation/devopsconf/devopsconf_en.html)),
|
||||
[video](https://vitastor.io/presentation/devopsconf/talk.webm)
|
||||
- Highload'2022: presentation ([in Russian](https://vitastor.io/presentation/highload/highload.html)),
|
||||
[video](https://vitastor.io/presentation/highload/talk.webm)
|
||||
## Architecture
|
||||
|
||||
## Documentation
|
||||
Similarities:
|
||||
|
||||
- Introduction
|
||||
- [Quick Start](docs/intro/quickstart.en.md)
|
||||
- [Features](docs/intro/features.en.md)
|
||||
- [Architecture](docs/intro/architecture.en.md)
|
||||
- [Author and license](docs/intro/author.en.md)
|
||||
- Installation
|
||||
- [Packages](docs/installation/packages.en.md)
|
||||
- [Proxmox](docs/installation/proxmox.en.md)
|
||||
- [OpenStack](docs/installation/openstack.en.md)
|
||||
- [Kubernetes CSI](docs/installation/kubernetes.en.md)
|
||||
- [Building from Source](docs/installation/source.en.md)
|
||||
- Configuration
|
||||
- [Overview](docs/config.en.md)
|
||||
- Parameter Reference
|
||||
- [Common](docs/config/common.en.md)
|
||||
- [Network](docs/config/network.en.md)
|
||||
- [Global Disk Layout](docs/config/layout-cluster.en.md)
|
||||
- [OSD Disk Layout](docs/config/layout-osd.en.md)
|
||||
- [OSD Runtime Parameters](docs/config/osd.en.md)
|
||||
- [Monitor](docs/config/monitor.en.md)
|
||||
- [Pool configuration](docs/config/pool.en.md)
|
||||
- [Image metadata in etcd](docs/config/inode.en.md)
|
||||
- Usage
|
||||
- [vitastor-cli](docs/usage/cli.en.md) (command-line interface)
|
||||
- [fio](docs/usage/fio.en.md) for benchmarks
|
||||
- [NBD](docs/usage/nbd.en.md) for kernel mounts
|
||||
- [QEMU and qemu-img](docs/usage/qemu.en.md)
|
||||
- [NFS](docs/usage/nfs.en.md) emulator for VMWare and similar
|
||||
- Performance
|
||||
- [Understanding storage performance](docs/performance/understanding.en.md)
|
||||
- [Theoretical performance](docs/performance/theoretical.en.md)
|
||||
- [Example comparison with Ceph](docs/performance/comparison1.en.md)
|
||||
- Just like Ceph, Vitastor has Pools, PGs, OSDs, Monitors, Failure Domains, Placement Tree.
|
||||
- Just like Ceph, Vitastor is transactional (even though there's a "lazy fsync mode" which
|
||||
doesn't implicitly flush every operation to disks).
|
||||
- OSDs also have journal and metadata and they can also be put on separate drives.
|
||||
- Just like in Ceph, client library attempts to recover from any cluster failure so
|
||||
you can basically reboot the whole cluster and only pause, but not crash, your clients
|
||||
(I consider this a bug if the client crashes in that case).
|
||||
|
||||
Some basic terms for people not familiar with Ceph:
|
||||
|
||||
- OSD (Object Storage Daemon) is a process that stores data and serves read/write requests.
|
||||
- PG (Placement Group) is a container for data that (normally) shares the same replicas.
|
||||
- Pool is a container for data that has the same redundancy scheme and placement rules.
|
||||
- Monitor is a separate daemon that watches cluster state and handles failures.
|
||||
- Failure Domain is a group of OSDs that you allow to fail. It's "host" by default.
|
||||
- Placement Tree groups OSDs in a hierarchy to later split them into Failure Domains.
|
||||
|
||||
Architectural differences from Ceph:
|
||||
|
||||
- Vitastor's primary focus is on SSDs. Proper SSD+HDD optimizations may be added in the future, though.
|
||||
- Vitastor OSD is (and will always be) single-threaded. If you want to dedicate more than 1 core
|
||||
per drive you should run multiple OSDs each on a different partition of the drive.
|
||||
Vitastor isn't CPU-hungry though (as opposed to Ceph), so 1 core is sufficient in a lot of cases.
|
||||
- Metadata and journal are always kept in memory. Metadata size depends linearly on drive capacity
|
||||
and data store block size which is 128 KB by default. With 128 KB blocks metadata should occupy
|
||||
around 512 MB per 1 TB (which is still less than Ceph wants). Journal doesn't have to be big,
|
||||
the example test below was conducted with only 16 MB journal. A big journal is probably even
|
||||
harmful as dirty write metadata also take some memory.
|
||||
- Vitastor storage layer doesn't have internal copy-on-write or redirect-write. I know that maybe
|
||||
it's possible to create a good copy-on-write storage, but it's much harder and makes performance
|
||||
less deterministic, so CoW isn't used in Vitastor.
|
||||
- The basic layer of Vitastor is block storage with fixed-size blocks, not object storage with
|
||||
rich semantics like in Ceph (RADOS).
|
||||
- There's a "lazy fsync" mode which allows to batch writes before flushing them to the disk.
|
||||
This allows to use Vitastor with desktop SSDs, but still lowers performance due to additional
|
||||
network roundtrips, so use server SSDs with capacitor-based power loss protection
|
||||
("Advanced Power Loss Protection") for best performance.
|
||||
- PGs are ephemeral. This means that they aren't stored on data disks and only exist in memory
|
||||
while OSDs are running.
|
||||
- Recovery process is per-object (per-block), not per-PG. Also there are no PGLOGs.
|
||||
- Monitors don't store data. Cluster configuration and state is stored in etcd in simple human-readable
|
||||
JSON structures. Monitors only watch cluster state and handle data movement.
|
||||
Thus Vitastor's Monitor isn't a critical component of the system and is more similar to Ceph's Manager.
|
||||
Vitastor's Monitor is implemented in node.js.
|
||||
- PG distribution isn't based on consistent hashes. All PG mappings are stored in etcd.
|
||||
Rebalancing PGs between OSDs is done by mathematical optimization - data distribution problem
|
||||
is reduced to a linear programming problem and solved by lp_solve. This allows for almost
|
||||
perfect (96-99% uniformity compared to Ceph's 80-90%) data distribution in most cases, ability
|
||||
to map PGs by hand without breaking rebalancing logic, reduced OSD peer-to-peer communication
|
||||
(on average, OSDs have fewer peers) and less data movement. It also probably has a drawback -
|
||||
this method may fail in very large clusters, but up to several hundreds of OSDs it's perfectly fine.
|
||||
It's also easy to add consistent hashes in the future if something proves their necessity.
|
||||
- There's no separate CRUSH layer. You select pool redundancy scheme, placement root, failure domain
|
||||
and so on directly in pool configuration.
|
||||
|
||||
## Understanding Storage Performance
|
||||
|
||||
The most important thing for fast storage is latency, not parallel iops.
|
||||
|
||||
The best possible latency is achieved with one thread and queue depth of 1 which basically means
|
||||
"client load as low as possible". In this case IOPS = 1/latency, and this number doesn't
|
||||
scale with number of servers, drives, server processes or threads and so on.
|
||||
Single-threaded IOPS and latency numbers only depend on *how fast a single daemon is*.
|
||||
|
||||
Why is it important? It's important because some of the applications *can't* use
|
||||
queue depth greater than 1 because their task isn't parallelizable. A notable example
|
||||
is any ACID DBMS because all of them write their WALs sequentially with fsync()s.
|
||||
|
||||
fsync, by the way, is another important thing often missing in benchmarks. The point is
|
||||
that drives have cache buffers and don't guarantee that your data is actually persisted
|
||||
until you call fsync() which is translated to a FLUSH CACHE command by the OS.
|
||||
|
||||
Desktop SSDs are very fast without fsync - NVMes, for example, can process ~80000 write
|
||||
operations per second with queue depth of 1 without fsync - but they're really slow with
|
||||
fsync because they have to actually write data to flash chips when you call fsync. Typical
|
||||
number is around 1000-2000 iops with fsync.
|
||||
|
||||
Server SSDs often have supercapacitors that act as a built-in UPS and allow the drive
|
||||
to flush its DRAM cache to the persistent flash storage when a power loss occurs.
|
||||
This makes them perform equally well with and without fsync. This feature is called
|
||||
"Advanced Power Loss Protection" by Intel; other vendors either call it similarly
|
||||
or directly as "Full Capacitor-Based Power Loss Protection".
|
||||
|
||||
All software-defined storages that I currently know are slow in terms of latency.
|
||||
Notable examples are Ceph and internal SDSes used by cloud providers like Amazon, Google,
|
||||
Yandex and so on. They're all slow and can only reach ~0.3ms read and ~0.6ms 4 KB write latency
|
||||
with best-in-slot hardware.
|
||||
|
||||
And that's in the SSD era when you can buy an SSD that has ~0.04ms latency for 100 $.
|
||||
|
||||
I use the following 6 commands with small variations to benchmark any storage:
|
||||
|
||||
- Linear write:
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
|
||||
- Linear read:
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
|
||||
- Random write latency (T1Q1, this hurts storages the most):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Random read latency (T1Q1):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
- Parallel write iops (use numjobs if a single CPU core is insufficient to saturate the load):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Parallel read iops (use numjobs if a single CPU core is insufficient to saturate the load):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
|
||||
## Vitastor's Theoretical Maximum Random Access Performance
|
||||
|
||||
Replicated setups:
|
||||
- Single-threaded (T1Q1) read latency: 1 network roundtrip + 1 disk read.
|
||||
- Single-threaded write+fsync latency:
|
||||
- With immediate commit: 2 network roundtrips + 1 disk write.
|
||||
- With lazy commit: 4 network roundtrips + 1 disk write + 1 disk flush.
|
||||
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
||||
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops / number of replicas / write amplification)).
|
||||
|
||||
EC/XOR setups:
|
||||
- Single-threaded (T1Q1) read latency: 1.5 network roundtrips + 1 disk read.
|
||||
- Single-threaded write+fsync latency:
|
||||
- With immediate commit: 3.5 network roundtrips + 1 disk read + 2 disk writes.
|
||||
- With lazy commit: 5.5 network roundtrips + 1 disk read + 2 disk writes + 2 disk fsyncs.
|
||||
- 0.5 in actually (k-1)/k which means that an additional roundtrip doesn't happen when
|
||||
the read sub-operation can be served locally.
|
||||
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
||||
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops * number of data drives / (number of data + parity drives) / write amplification)).
|
||||
In fact, you should put disk write iops under the condition of ~10% reads / ~90% writes in this formula.
|
||||
|
||||
Write amplification for 4 KB blocks is usually 3-5 in Vitastor:
|
||||
1. Journal block write
|
||||
2. Journal data write
|
||||
3. Metadata block write
|
||||
4. Another journal block write for EC/XOR setups
|
||||
5. Data block write
|
||||
|
||||
If you manage to get an SSD which handles 512 byte blocks well (Optane?) you may
|
||||
lower 1, 3 and 4 to 512 bytes (1/8 of data size) and get WA as low as 2.375.
|
||||
|
||||
Lazy fsync also reduces WA for parallel workloads because journal blocks are only
|
||||
written when they fill up or fsync is requested.
|
||||
|
||||
## Example Comparison with Ceph
|
||||
|
||||
Hardware configuration: 4 nodes, each with:
|
||||
- 6x SATA SSD Intel D3-4510 3.84 TB
|
||||
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
|
||||
- 384 GB RAM
|
||||
- 1x 25 GbE network interface (Mellanox ConnectX-4 LX), connected to a Juniper QFX5200 switch
|
||||
|
||||
CPU powersaving was disabled. Both Vitastor and Ceph were configured with 2 OSDs per 1 SSD.
|
||||
|
||||
All of the results below apply to 4 KB blocks and random access (unless indicated otherwise).
|
||||
|
||||
Raw drive performance:
|
||||
- T1Q1 write ~27000 iops (~0.037ms latency)
|
||||
- T1Q1 read ~9800 iops (~0.101ms latency)
|
||||
- T1Q32 write ~60000 iops
|
||||
- T1Q32 read ~81700 iops
|
||||
|
||||
Ceph 15.2.4 (Bluestore):
|
||||
- T1Q1 write ~1000 iops (~1ms latency)
|
||||
- T1Q1 read ~1750 iops (~0.57ms latency)
|
||||
- T8Q64 write ~100000 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
- T8Q64 read ~480000 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
|
||||
T8Q64 tests were conducted over 8 400GB RBD images from all hosts (every host was running 2 instances of fio).
|
||||
This is because Ceph has performance penalties related to running multiple clients over a single RBD image.
|
||||
|
||||
cephx_sign_messages was set to false during tests, RocksDB and Bluestore settings were left at defaults.
|
||||
|
||||
In fact, not that bad for Ceph. These servers are an example of well-balanced Ceph nodes.
|
||||
However, CPU usage and I/O latency were through the roof, as usual.
|
||||
|
||||
Vitastor:
|
||||
- T1Q1 write: 7087 iops (0.14ms latency)
|
||||
- T1Q1 read: 6838 iops (0.145ms latency)
|
||||
- T2Q64 write: 162000 iops, total CPU usage by OSDs about 3 virtual cores on each node
|
||||
- T8Q64 read: 895000 iops, total CPU usage by OSDs about 4 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 2800 MB/s
|
||||
- Linear read (4M T1Q32): 1500 MB/s
|
||||
|
||||
T8Q64 read test was conducted over 1 larger inode (3.2T) from all hosts (every host was running 2 instances of fio).
|
||||
Vitastor has no performance penalties related to running multiple clients over a single inode.
|
||||
If conducted from one node with all primary OSDs moved to other nodes the result was slightly lower (689000 iops),
|
||||
this is because all operations resulted in network roundtrips between the client and the primary OSD.
|
||||
When fio was colocated with OSDs (like in Ceph benchmarks above), 1/4 of the read workload actually
|
||||
used the loopback network.
|
||||
|
||||
Vitastor was configured with: `--disable_data_fsync true --immediate_commit all --flusher_count 8
|
||||
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
|
||||
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
|
||||
--journal_size 16777216`.
|
||||
|
||||
### EC/XOR 2+1
|
||||
|
||||
Vitastor:
|
||||
- T1Q1 write: 2808 iops (~0.355ms latency)
|
||||
- T1Q1 read: 6190 iops (~0.16ms latency)
|
||||
- T2Q64 write: 85500 iops, total CPU usage by OSDs about 3.4 virtual cores on each node
|
||||
- T8Q64 read: 812000 iops, total CPU usage by OSDs about 4.7 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 3200 MB/s
|
||||
- Linear read (4M T1Q32): 1800 MB/s
|
||||
|
||||
Ceph:
|
||||
- T1Q1 write: 730 iops (~1.37ms latency)
|
||||
- T1Q1 read: 1500 iops with cold cache (~0.66ms latency), 2300 iops after 2 minute metadata cache warmup (~0.435ms latency)
|
||||
- T4Q128 write (4 RBD images): 45300 iops, total CPU usage by OSDs about 30 virtual cores on each node
|
||||
- T8Q64 read (4 RBD images): 278600 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 1950 MB/s before preallocation, 2500 MB/s after preallocation
|
||||
- Linear read (4M T1Q32): 2400 MB/s
|
||||
|
||||
### NBD
|
||||
|
||||
NBD is currently required to mount Vitastor via kernel, but it imposes additional overhead
|
||||
due to additional copying between the kernel and userspace. This mostly hurts linear
|
||||
bandwidth, not iops.
|
||||
|
||||
Vitastor with single-thread NBD on the same hardware:
|
||||
- T1Q1 write: 6000 iops (0.166ms latency)
|
||||
- T1Q1 read: 5518 iops (0.18ms latency)
|
||||
- T1Q128 write: 94400 iops
|
||||
- T1Q128 read: 103000 iops
|
||||
- Linear write (4M T1Q128): 1266 MB/s (compared to 2800 MB/s via fio)
|
||||
- Linear read (4M T1Q128): 975 MB/s (compared to 1500 MB/s via fio)
|
||||
|
||||
## Installation
|
||||
|
||||
### Debian
|
||||
|
||||
- Trust Vitastor package signing key:
|
||||
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
|
||||
- Add Vitastor package repository to your /etc/apt/sources.list:
|
||||
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
|
||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||
- For Debian 10 (Buster) also enable backports repository:
|
||||
`deb http://deb.debian.org/debian buster-backports main`
|
||||
- Install packages: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
|
||||
|
||||
### CentOS
|
||||
|
||||
- Add Vitastor package repository:
|
||||
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
|
||||
- Enable EPEL: `yum/dnf install epel-release`
|
||||
- Enable additional CentOS repositories:
|
||||
- CentOS 7: `yum install centos-release-scl`
|
||||
- CentOS 8: `dnf install centos-release-advanced-virtualization`
|
||||
- Enable elrepo-kernel:
|
||||
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
|
||||
- Install packages: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
|
||||
|
||||
### Building from Source
|
||||
|
||||
- Install Linux kernel 5.4 or newer, for io_uring support. 5.8 or later is highly recommended because
|
||||
there is at least one known io_uring hang with 5.4 and an HP SmartArray controller.
|
||||
- Install liburing 0.4 or newer and its headers.
|
||||
- Install lp_solve.
|
||||
- Install etcd, at least version 3.4.15. Earlier versions won't work because of various bugs,
|
||||
for example [#12402](https://github.com/etcd-io/etcd/pull/12402). You can also take 3.4.13
|
||||
with this specific fix from here: https://github.com/vitalif/etcd/, branch release-3.4.
|
||||
- Install node.js 10 or newer.
|
||||
- Install gcc and g++ 8.x or newer.
|
||||
- Clone https://yourcmc.ru/git/vitalif/vitastor/ with submodules.
|
||||
- Install QEMU 3.0+, get its source, begin to build it, stop the build and copy headers:
|
||||
- `<qemu>/include` → `<vitastor>/qemu/include`
|
||||
- Debian:
|
||||
* Use qemu packages from the main repository
|
||||
* `<qemu>/b/qemu/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* `<qemu>/b/qemu/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
- CentOS 8:
|
||||
* Use qemu packages from the Advanced-Virtualization repository. To enable it, run
|
||||
`yum install centos-release-advanced-virtualization.noarch` and then `yum install qemu`
|
||||
* `<qemu>/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* For QEMU 3.0+: `<qemu>/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
* For QEMU 2.0+: `<qemu>/qapi-types.h` → `<vitastor>/qemu/b/qemu/qapi-types.h`
|
||||
- `config-host.h` and `qapi` are required because they contain generated headers
|
||||
- You can also rebuild QEMU with a patch that makes LD_PRELOAD unnecessary to load vitastor driver.
|
||||
See `patches/qemu-*.*-vitastor.patch`.
|
||||
- Install fio 3.7 or later, get its source and symlink it into `<vitastor>/fio`.
|
||||
- Build & install Vitastor with `mkdir build && cd build && cmake .. && make -j8 && make install`.
|
||||
Pay attention to the `QEMU_PLUGINDIR` cmake option - it must be set to `qemu-kvm` on RHEL.
|
||||
|
||||
## Running
|
||||
|
||||
Please note that startup procedure isn't currently simple - you specify configuration
|
||||
and calculate disk offsets almost by hand. This will be fixed in near future.
|
||||
|
||||
- Get some SATA or NVMe SSDs with capacitors (server-grade drives). You can use desktop SSDs
|
||||
with lazy fsync, but prepare for inferior single-thread latency.
|
||||
- Get a fast network (at least 10 Gbit/s).
|
||||
- Disable CPU powersaving: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||
- On the monitor hosts:
|
||||
- Edit variables at the top of `/usr/lib/vitastor/mon/make-units.sh` to desired values.
|
||||
- Create systemd units for the monitor and etcd: `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Start etcd and monitors: `systemctl start etcd vitastor-mon`
|
||||
- Put etcd_address and osd_network into `/etc/vitastor/vitastor.conf`. Example:
|
||||
```
|
||||
{
|
||||
"etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"],
|
||||
"osd_network": "10.200.1.0/24"
|
||||
}
|
||||
```
|
||||
- Initialize OSDs:
|
||||
- Simplest, SSD-only: `/usr/lib/vitastor/mon/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`
|
||||
- Hybrid, HDD+SSD: `/usr/lib/vitastor/mon/make-osd-hybrid.js /dev/sda /dev/sdb ...` - pass all your
|
||||
devices (HDD and SSD) to this script - it will partition disks and initialize journals on its own.
|
||||
This script skips HDDs which are already partitioned so if you want to use non-empty disks for
|
||||
Vitastor you should first wipe them with `wipefs -a`. SSDs with GPT partition table are not skipped,
|
||||
but some free unpartitioned space must be available because the script creates new partitions for journals.
|
||||
- You can change OSD configuration in units or in `vitastor.conf`. Notable configuration variables:
|
||||
- `disable_data_fsync 1` - only safe with server-grade drives with capacitors.
|
||||
- `immediate_commit all` - use this if all your drives are server-grade.
|
||||
If all OSDs have it set to all then you should also put the same value in etcd into /vitastor/config/global
|
||||
- `disable_device_lock 1` - only required if you run multiple OSDs on one block device.
|
||||
- `flusher_count 256` - flusher is a micro-thread that removes old data from the journal.
|
||||
You don't have to worry about this parameter anymore, 256 is enough.
|
||||
- `disk_alignment`, `journal_block_size`, `meta_block_size` should be set to the internal
|
||||
block size of your SSDs which is 4096 on most drives.
|
||||
- `journal_no_same_sector_overwrites true` prevents multiple overwrites of the same journal sector.
|
||||
Most (99%) SSDs don't need this option. But Intel D3-4510 does because it doesn't like when you
|
||||
overwrite the same sector twice in a short period of time. The setting forces Vitastor to never
|
||||
overwrite the same journal sector twice in a row which makes D3-4510 almost happy. Not totally
|
||||
happy, because overwrites of the same block can still happen in the metadata area... When this
|
||||
setting is set, it is also required to raise `journal_sector_buffer_count` setting, which is the
|
||||
number of dirty journal sectors that may be written to at the same time.
|
||||
- `systemctl start vitastor.target` everywhere.
|
||||
- Create global configuration in etcd: `etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||
(if all your drives have capacitors).
|
||||
- Create pool configuration in etcd: `etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool","scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'`.
|
||||
For jerasure pools the configuration should look like the following: `2:{"name":"ecpool","scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`.
|
||||
- At this point, one of the monitors will configure PGs and OSDs will start them.
|
||||
- You can check PG states with `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. All PGs should become 'active'.
|
||||
|
||||
### Name an image
|
||||
|
||||
```
|
||||
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
|
||||
```
|
||||
|
||||
For example:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
|
||||
```
|
||||
|
||||
If you specify parent_id the image becomes a CoW clone. I.e. all writes go to the new inode and reads first check it
|
||||
and then upper layers. You can then make parent readonly by updating its entry with `"readonly":true` for safety and
|
||||
basically treat it as a snapshot.
|
||||
|
||||
So to create a snapshot you basically rename the previous upper layer (for example from testimg to testimg@0), make it readonly
|
||||
and create a new top layer with the original name (testimg) and the previous one as a parent.
|
||||
|
||||
### Run fio benchmarks
|
||||
|
||||
fio command example:
|
||||
|
||||
```
|
||||
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
|
||||
```
|
||||
|
||||
If you don't want to access your image by name, you can specify pool number, inode number and size
|
||||
(`-pool=1 -inode=1 -size=400G`) instead of the image name (`-image=testimg`).
|
||||
|
||||
### Upload VM image
|
||||
|
||||
Use qemu-img and `vitastor:etcd_host=<HOST>:image=<IMAGE>` disk filename. For example:
|
||||
|
||||
```
|
||||
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg'
|
||||
```
|
||||
|
||||
Note that the command requires to be run with `LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so qemu-img ...`
|
||||
if you use unmodified QEMU.
|
||||
|
||||
You can also specify `:pool=<POOL>:inode=<INODE>:size=<SIZE>` instead of `:image=<IMAGE>`
|
||||
if you don't want to use inode metadata.
|
||||
|
||||
### Start a VM
|
||||
|
||||
Run QEMU with `-drive file=vitastor:etcd_host=<HOST>:image=<IMAGE>` and use 4 KB physical block size.
|
||||
|
||||
For example:
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024
|
||||
-drive 'file=vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg',format=raw,if=none,id=drive-virtio-disk0,cache=none
|
||||
-device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1,write-cache=off,physical_block_size=4096,logical_block_size=512
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
You can also specify `:pool=<POOL>:inode=<INODE>:size=<SIZE>` instead of `:image=<IMAGE>`,
|
||||
just like in qemu-img.
|
||||
|
||||
### Remove inode
|
||||
|
||||
Use vitastor-rm / vitastor-cli rm-data. For example:
|
||||
|
||||
```
|
||||
vitastor-cli rm-data --etcd_address 10.115.0.10:2379/v3 --pool 1 --inode 1 --parallel_osds 16 --iodepth 32
|
||||
```
|
||||
|
||||
### NBD
|
||||
|
||||
To create a local block device for a Vitastor image, use NBD. For example:
|
||||
|
||||
```
|
||||
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
|
||||
```
|
||||
|
||||
It will output the device name, like /dev/nbd0 which you can then format and mount as a normal block device.
|
||||
|
||||
Again, you can use `--pool <POOL> --inode <INODE> --size <SIZE>` insteaf of `--image <IMAGE>` if you want.
|
||||
|
||||
### Kubernetes
|
||||
|
||||
Vitastor has a CSI plugin for Kubernetes which supports RWO volumes.
|
||||
|
||||
To deploy it, take manifests from [csi/deploy/](csi/deploy/) directory, put your
|
||||
Vitastor configuration in [csi/deploy/001-csi-config-map.yaml](001-csi-config-map.yaml),
|
||||
configure storage class in [csi/deploy/009-storage-class.yaml](009-storage-class.yaml)
|
||||
and apply all `NNN-*.yaml` manifests to your Kubernetes installation:
|
||||
|
||||
```
|
||||
for i in ./???-*.yaml; do kubectl apply -f $i; done
|
||||
```
|
||||
|
||||
After that you'll be able to create PersistentVolumes. See example in [csi/deploy/example-pvc.yaml](csi/deploy/example-pvc.yaml).
|
||||
|
||||
### OpenStack
|
||||
|
||||
To enable Vitastor support in an OpenStack installation:
|
||||
|
||||
- Install vitastor-client, patched QEMU and libvirt packages from Vitastor DEB or RPM repository
|
||||
- Use `patches/nova-21.diff` or `patches/nova-23.diff` to patch your Nova installation.
|
||||
Patch 21 fits Nova 21-22, patch 23 fits Nova 23-24.
|
||||
- Install `patches/cinder-vitastor.py` as `..../cinder/volume/drivers/vitastor.py`
|
||||
- Define a volume type in cinder.conf (see below)
|
||||
- Block network access from VMs to Vitastor network (to OSDs and etcd), because Vitastor doesn't support authentication (yet)
|
||||
- Restart Cinder and Nova
|
||||
|
||||
Cinder volume type configuration example:
|
||||
|
||||
```
|
||||
[DEFAULT]
|
||||
enabled_backends = lvmdriver-1, vitastor-testcluster
|
||||
# ...
|
||||
|
||||
[vitastor-testcluster]
|
||||
volume_driver = cinder.volume.drivers.vitastor.VitastorDriver
|
||||
volume_backend_name = vitastor-testcluster
|
||||
image_volume_cache_enabled = True
|
||||
volume_clear = none
|
||||
vitastor_etcd_address = 192.168.7.2:2379
|
||||
vitastor_etcd_prefix =
|
||||
vitastor_config_path = /etc/vitastor/vitastor.conf
|
||||
vitastor_pool_id = 1
|
||||
image_upload_use_cinder_backend = True
|
||||
```
|
||||
|
||||
To put Glance images in Vitastor, use [https://docs.openstack.org/cinder/pike/admin/blockstorage-volume-backed-image.html](volume-backed images),
|
||||
although the support has not been verified yet.
|
||||
|
||||
### Proxmox
|
||||
|
||||
To enable Vitastor support in Proxmox Virtual Environment (6.4 and 7.1 are supported):
|
||||
|
||||
- Add the corresponding Vitastor Debian repository into sources.list on Proxmox hosts
|
||||
(buster for 6.4, bullseye for 7.1)
|
||||
- Install vitastor-client, pve-qemu-kvm, pve-storage-vitastor (* or see note) packages from Vitastor repository
|
||||
- Define storage in `/etc/pve/storage.cfg` (see below)
|
||||
- Block network access from VMs to Vitastor network (to OSDs and etcd), because Vitastor doesn't support authentication (yet)
|
||||
- Restart pvedaemon: `systemctl restart pvedaemon`
|
||||
|
||||
`/etc/pve/storage.cfg` example (the only required option is vitastor_pool, all others
|
||||
are listed below with their default values):
|
||||
|
||||
```
|
||||
vitastor: vitastor
|
||||
# pool to put new images into
|
||||
vitastor_pool testpool
|
||||
# path to the configuration file
|
||||
vitastor_config_path /etc/vitastor/vitastor.conf
|
||||
# etcd address(es), required only if missing in the configuration file
|
||||
vitastor_etcd_address 192.168.7.2:2379/v3
|
||||
# prefix for keys in etcd
|
||||
vitastor_etcd_prefix /vitastor
|
||||
# prefix for images
|
||||
vitastor_prefix pve/
|
||||
# use NBD mounter (only required for containers)
|
||||
vitastor_nbd 0
|
||||
```
|
||||
|
||||
\* Note: you can also manually copy [patches/PVE_VitastorPlugin.pm](patches/PVE_VitastorPlugin.pm) to Proxmox hosts
|
||||
as `/usr/share/perl5/PVE/Storage/Custom/VitastorPlugin.pm` instead of installing pve-storage-vitastor.
|
||||
|
||||
## Known Problems
|
||||
|
||||
- Object deletion requests may currently lead to 'incomplete' objects in EC pools
|
||||
if your OSDs crash during deletion because proper handling of object cleanup
|
||||
in a cluster should be "three-phase" and it's currently not implemented.
|
||||
Just repeat the removal request again in this case.
|
||||
|
||||
## Implementation Principles
|
||||
|
||||
- I like architecturally simple solutions. Vitastor is and will always be designed
|
||||
exactly like that.
|
||||
- I also like reinventing the wheel to some extent, like writing my own HTTP client
|
||||
for etcd interaction instead of using prebuilt libraries, because in this case
|
||||
I'm confident about what my code does and what it doesn't do.
|
||||
- I don't care about C++ "best practices" like RAII or proper inheritance or usage of
|
||||
smart pointers or whatever and I don't intend to change my mind, so if you're here
|
||||
looking for ideal reference C++ code, this probably isn't the right place.
|
||||
- I like node.js better than any other dynamically-typed language interpreter
|
||||
because it's faster than any other interpreter in the world, has neutral C-like
|
||||
syntax and built-in event loop. That's why Monitor is implemented in node.js.
|
||||
|
||||
## Author and License
|
||||
|
||||
|
|
|
@ -1 +1 @@
|
|||
Subproject commit 45e6d1f13196a0824e2089a586c53b9de0283f17
|
||||
Subproject commit 6e201464060ace53db809d65da7b0e2800673f8f
|
|
@ -1,4 +1,4 @@
|
|||
VERSION ?= v0.6.17
|
||||
VERSION ?= v0.6.16
|
||||
|
||||
all: build push
|
||||
|
||||
|
|
|
@ -49,7 +49,7 @@ spec:
|
|||
capabilities:
|
||||
add: ["SYS_ADMIN"]
|
||||
allowPrivilegeEscalation: true
|
||||
image: vitalif/vitastor-csi:v0.6.17
|
||||
image: vitalif/vitastor-csi:v0.6.16
|
||||
args:
|
||||
- "--node=$(NODE_ID)"
|
||||
- "--endpoint=$(CSI_ENDPOINT)"
|
||||
|
|
|
@ -116,7 +116,7 @@ spec:
|
|||
privileged: true
|
||||
capabilities:
|
||||
add: ["SYS_ADMIN"]
|
||||
image: vitalif/vitastor-csi:v0.6.17
|
||||
image: vitalif/vitastor-csi:v0.6.16
|
||||
args:
|
||||
- "--node=$(NODE_ID)"
|
||||
- "--endpoint=$(CSI_ENDPOINT)"
|
||||
|
|
|
@ -5,7 +5,7 @@ package vitastor
|
|||
|
||||
const (
|
||||
vitastorCSIDriverName = "csi.vitastor.io"
|
||||
vitastorCSIDriverVersion = "0.6.17"
|
||||
vitastorCSIDriverVersion = "0.6.16"
|
||||
)
|
||||
|
||||
// Config struct fills the parameters of request or user input
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
vitastor (0.6.17-1) unstable; urgency=medium
|
||||
vitastor (0.6.16-1) unstable; urgency=medium
|
||||
|
||||
* RDMA support
|
||||
* Bugfixes
|
||||
|
|
|
@ -2,6 +2,5 @@ usr/bin/vita
|
|||
usr/bin/vitastor-cli
|
||||
usr/bin/vitastor-rm
|
||||
usr/bin/vitastor-nbd
|
||||
usr/bin/vitastor-nfs
|
||||
usr/lib/*/libvitastor*.so*
|
||||
mon/make-osd.sh /usr/lib/vitastor
|
||||
|
|
|
@ -33,8 +33,8 @@ RUN set -e -x; \
|
|||
mkdir -p /root/packages/vitastor-$REL; \
|
||||
rm -rf /root/packages/vitastor-$REL/*; \
|
||||
cd /root/packages/vitastor-$REL; \
|
||||
cp -r /root/vitastor vitastor-0.6.17; \
|
||||
cd vitastor-0.6.17; \
|
||||
cp -r /root/vitastor vitastor-0.6.16; \
|
||||
cd vitastor-0.6.16; \
|
||||
ln -s /root/fio-build/fio-*/ ./fio; \
|
||||
FIO=$(head -n1 fio/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
||||
ls /usr/include/linux/raw.h || cp ./debian/raw.h /usr/include/linux/raw.h; \
|
||||
|
@ -47,8 +47,8 @@ RUN set -e -x; \
|
|||
rm -rf a b; \
|
||||
echo "dep:fio=$FIO" > debian/fio_version; \
|
||||
cd /root/packages/vitastor-$REL; \
|
||||
tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_0.6.17.orig.tar.xz vitastor-0.6.17; \
|
||||
cd vitastor-0.6.17; \
|
||||
tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_0.6.16.orig.tar.xz vitastor-0.6.16; \
|
||||
cd vitastor-0.6.16; \
|
||||
V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
||||
DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v "$V""$REL" "Rebuild for $REL"; \
|
||||
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \
|
||||
|
|
|
@ -1,37 +0,0 @@
|
|||
[Documentation](../README.md#documentation) → Configuration Reference
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](config.ru.md)
|
||||
|
||||
# Configuration Reference
|
||||
|
||||
Vitastor configuration consists of:
|
||||
- [Configuration parameters (key-value)](#parameter-reference)
|
||||
- [Pool configuration](config/pool.en.md)
|
||||
- [OSD placement tree configuration](config/pool.en.md#placement-tree)
|
||||
- [Separate OSD settings](config/pool.en.md#osd-settings)
|
||||
- [Inode configuration](config/inode.en.md) i.e. image metadata like name, size and parent reference
|
||||
|
||||
Configuration parameters can be set in 3 places:
|
||||
- Configuration file (`/etc/vitastor/vitastor.conf` or other path)
|
||||
- etcd key `/vitastor/config/global`. Most variables can be set there, but etcd
|
||||
connection parameters should obviously be set in the configuration file.
|
||||
- Command line of Vitastor components: OSD, mon, fio and QEMU options,
|
||||
OpenStack/Proxmox/etc configuration. The latter doesn't allow to set all
|
||||
variables directly, but it allows to override the configuration file and
|
||||
set everything you need inside it.
|
||||
|
||||
In the future, additional configuration methods may be added:
|
||||
- OSD superblock which will, by design, contain parameters related to the disk
|
||||
layout and to one specific OSD.
|
||||
- OSD-specific keys in etcd like `/vitastor/config/osd/<number>`.
|
||||
|
||||
## Parameter Reference
|
||||
|
||||
- [Common](config/common.en.md)
|
||||
- [Network](config/network.en.md)
|
||||
- [Global Disk Layout](config/layout-cluster.en.md)
|
||||
- [OSD Disk Layout](config/layout-osd.en.md)
|
||||
- [OSD Runtime Parameters](config/osd.en.md)
|
||||
- [Monitor](config/monitor.en.md)
|
|
@ -1,39 +0,0 @@
|
|||
[Документация](../README-ru.md#документация) → Конфигурация Vitastor
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](config.en.md)
|
||||
|
||||
# Конфигурация Vitastor
|
||||
|
||||
Конфигурация Vitastor состоит из:
|
||||
- [Параметров (ключ-значение)](#список-параметров)
|
||||
- [Настроек пулов](config/pool.ru.md)
|
||||
- [Настроек дерева OSD](config/pool.ru.md#дерево-размещения)
|
||||
- [Настроек отдельных OSD](config/pool.ru.md#настройки-osd)
|
||||
- [Настроек инодов](config/inode.ru.md), т.е. метаданных образов, таких, как имя, размер и ссылки на
|
||||
родительский образ
|
||||
|
||||
Параметры конфигурации могут задаваться в 3 местах:
|
||||
- Файле конфигурации (`/etc/vitastor/vitastor.conf` или по другому пути)
|
||||
- Ключе в etcd `/vitastor/config/global`. Большая часть параметров может
|
||||
задаваться там, кроме, естественно, самих параметров соединения с etcd,
|
||||
которые должны задаваться в файле конфигурации
|
||||
- В командной строке компонентов Vitastor: OSD, монитора, опциях fio и QEMU,
|
||||
настроек OpenStack, Proxmox и т.п. Последние, как правило, не включают полный
|
||||
набор параметров напрямую, но разрешают определить путь к файлу конфигурации
|
||||
и задать любые параметры в нём.
|
||||
|
||||
В будущем также могут быть добавлены другие способы конфигурации:
|
||||
- Суперблок OSD, в котором будут храниться параметры OSD, связанные с дисковым
|
||||
форматом и с этим конкретным OSD.
|
||||
- OSD-специфичные ключи в etcd типа `/vitastor/config/osd/<номер>`.
|
||||
|
||||
## Список параметров
|
||||
|
||||
- [Общие](config/common.ru.md)
|
||||
- [Сеть](config/network.ru.md)
|
||||
- [Глобальные дисковые параметры](config/layout-cluster.ru.md)
|
||||
- [Дисковые параметры OSD](config/layout-osd.ru.md)
|
||||
- [Прочие параметры OSD](config/osd.ru.md)
|
||||
- [Параметры мониторов](config/monitor.ru.md)
|
|
@ -1,46 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Common Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](common.ru.md)
|
||||
|
||||
# Common Parameters
|
||||
|
||||
These are the most common parameters which apply to all components of Vitastor.
|
||||
|
||||
- [config_path](#config_path)
|
||||
- [etcd_address](#etcd_address)
|
||||
- [etcd_prefix](#etcd_prefix)
|
||||
- [log_level](#log_level)
|
||||
|
||||
## config_path
|
||||
|
||||
- Type: string
|
||||
- Default: /etc/vitastor/vitastor.conf
|
||||
|
||||
Path to the JSON configuration file. Configuration file is optional,
|
||||
a non-existing configuration file does not prevent Vitastor from
|
||||
running if required parameters are specified.
|
||||
|
||||
## etcd_address
|
||||
|
||||
- Type: string or array of strings
|
||||
|
||||
etcd connection endpoint(s). Multiple endpoints may be delimited by "," or
|
||||
specified in a JSON array `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
|
||||
Note that https is not supported for etcd connections yet.
|
||||
|
||||
## etcd_prefix
|
||||
|
||||
- Type: string
|
||||
- Default: /vitastor
|
||||
|
||||
Prefix for all keys in etcd used by Vitastor. You can change prefix and, for
|
||||
example, use a single etcd cluster for multiple Vitastor clusters.
|
||||
|
||||
## log_level
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Log level. Raise if you want more verbose output.
|
|
@ -1,45 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Общие параметры
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](common.en.md)
|
||||
|
||||
# Общие параметры
|
||||
|
||||
Это наиболее общие параметры, используемые всеми компонентами Vitastor.
|
||||
|
||||
- [config_path](#config_path)
|
||||
- [etcd_address](#etcd_address)
|
||||
- [etcd_prefix](#etcd_prefix)
|
||||
- [log_level](#log_level)
|
||||
|
||||
## config_path
|
||||
|
||||
- Тип: строка
|
||||
- Значение по умолчанию: /etc/vitastor/vitastor.conf
|
||||
|
||||
Путь к файлу конфигурации в формате JSON. Файл конфигурации необязателен,
|
||||
без него Vitastor тоже будет работать, если переданы необходимые параметры.
|
||||
|
||||
## etcd_address
|
||||
|
||||
- Тип: строка или массив строк
|
||||
|
||||
Адрес(а) подключения к etcd. Несколько адресов могут разделяться запятой
|
||||
или указываться в виде JSON-массива `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
|
||||
|
||||
## etcd_prefix
|
||||
|
||||
- Тип: строка
|
||||
- Значение по умолчанию: /vitastor
|
||||
|
||||
Префикс для ключей etcd, которые использует Vitastor. Вы можете задать другой
|
||||
префикс, например, чтобы запустить несколько кластеров Vitastor с одним
|
||||
кластером etcd.
|
||||
|
||||
## log_level
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 0
|
||||
|
||||
Уровень логгирования. Повысьте, если хотите более подробный вывод.
|
|
@ -1,32 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Image metadata in etcd
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](inode.ru.md)
|
||||
|
||||
# Image metadata in etcd
|
||||
|
||||
Image list is stored in etcd in `/vitastor/config/inode/<pool>/<inode>` keys.
|
||||
|
||||
You can even create images manually:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
|
||||
```
|
||||
|
||||
For example:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
|
||||
```
|
||||
|
||||
If you specify parent_id the image becomes a CoW clone. I.e. all writes go to the new inode and reads first check it
|
||||
and then upper layers. You can then make parent readonly by updating its entry with `"readonly":true` for safety and
|
||||
basically treat it as a snapshot.
|
||||
|
||||
So to create a snapshot you basically rename the previous upper layer (for example from testimg to testimg@0), make it readonly
|
||||
and create a new top layer with the original name (testimg) and the previous one as a parent.
|
||||
|
||||
vitastor-cli, K8s, OpenStack and other drivers also store the reverse mapping in `/vitastor/index/image/<name>` keys
|
||||
in JSON format: `{"id":<inode>,"pool_id":<pool>}` and ID counters in `/vitastor/index/maxid/<pool>` as numbers
|
||||
to simplify ID generation.
|
|
@ -1,34 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Метаданные образов в etcd
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](inode.en.md)
|
||||
|
||||
# Метаданные образов в etcd
|
||||
|
||||
Список образов хранится в etcd в ключах `/vitastor/config/inode/<pool>/<inode>`.
|
||||
|
||||
Вы можете даже создавать образы вручную:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
|
||||
```
|
||||
|
||||
Например:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
|
||||
```
|
||||
|
||||
Если вы зададите parent_id, то образ станет CoW-клоном, т.е. все новые запросы записи пойдут в новый инод, а запросы
|
||||
чтения будут проверять сначала его, а потом родительские слои по цепочке вверх. Чтобы случайно не перезаписать данные
|
||||
в родительском слое, вы можете переключить его в режим "только чтение", добавив флаг `"readonly":true` в его запись
|
||||
метаданных. В таком случае родительский образ становится просто снапшотом.
|
||||
|
||||
Таким образом, для создания снапшота вам нужно просто переименовать предыдущий inode (например, из testimg в testimg@0),
|
||||
сделать его readonly и создать новый слой с исходным именем образа (testimg), ссылающийся на только что переименованный
|
||||
в качестве родительского.
|
||||
|
||||
vitastor-cli и драйвера K8s, OpenStack и т.п. также хранят обратный маппинг в ключах `/vitastor/index/image/<name>`
|
||||
в JSON-формате: `{"id":<inode>,"pool_id":<pool>}` и счётчики ID `/vitastor/index/maxid/<pool>` в виде просто чисел
|
||||
для упрощения генерации ID новых образов.
|
|
@ -1,124 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Cluster-Wide Disk Layout Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](layout-cluster.ru.md)
|
||||
|
||||
# Cluster-Wide Disk Layout Parameters
|
||||
|
||||
These parameters apply to clients and OSDs, are fixed at the moment of OSD drive
|
||||
initialization and can't be changed after it without losing data.
|
||||
|
||||
- [block_size](#block_size)
|
||||
- [bitmap_granularity](#bitmap_granularity)
|
||||
- [immediate_commit](#immediate_commit)
|
||||
- [client_dirty_limit](#client_dirty_limit)
|
||||
|
||||
## block_size
|
||||
|
||||
- Type: integer
|
||||
- Default: 131072
|
||||
|
||||
Size of objects (data blocks) into which all physical and virtual drives are
|
||||
subdivided in Vitastor. One of current main settings in Vitastor, affects
|
||||
memory usage, write amplification and I/O load distribution effectiveness.
|
||||
|
||||
Recommended default block size is 128 KB for SSD and 4 MB for HDD. In fact,
|
||||
it's possible to use 4 MB for SSD too - it will lower memory usage, but
|
||||
may increase average WA and reduce linear performance.
|
||||
|
||||
OSDs with different block sizes (for example, SSD and SSD+HDD OSDs) can
|
||||
currently coexist in one etcd instance only within separate Vitastor
|
||||
clusters with different etcd_prefix'es.
|
||||
|
||||
Also block size can't be changed after OSD initialization without losing
|
||||
data.
|
||||
|
||||
You must always specify block_size in etcd in /vitastor/config/global if
|
||||
you change it so all clients can know about it.
|
||||
|
||||
OSD memory usage is roughly (SIZE / BLOCK * 68 bytes) which is roughly
|
||||
544 MB per 1 TB of used disk space with the default 128 KB block size.
|
||||
|
||||
## bitmap_granularity
|
||||
|
||||
- Type: integer
|
||||
- Default: 4096
|
||||
|
||||
Required virtual disk write alignment ("sector size"). Must be a multiple
|
||||
of disk_alignment. It's called bitmap granularity because Vitastor tracks
|
||||
an allocation bitmap for each object containing 2 bits per each
|
||||
(bitmap_granularity) bytes.
|
||||
|
||||
This parameter can't be changed after OSD initialization without losing
|
||||
data. Also it's fixed for the whole Vitastor cluster i.e. two different
|
||||
values can't be used in a single Vitastor cluster.
|
||||
|
||||
Clients MUST be aware of this parameter value, so put it into etcd key
|
||||
/vitastor/config/global if you change it for any reason.
|
||||
|
||||
## immediate_commit
|
||||
|
||||
- Type: string
|
||||
- Default: false
|
||||
|
||||
Another parameter which is really important for performance.
|
||||
|
||||
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
||||
without cache flush. However, they are really slow (only around 1000 iops)
|
||||
if you try to fsync() each write, that is, when you want to guarantee that
|
||||
each change gets immediately persisted to the physical media.
|
||||
|
||||
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
||||
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
||||
fast with and without fsync because their cache is protected from sudden
|
||||
power loss by a built-in supercapacitor-based "UPS".
|
||||
|
||||
Some software-defined storage systems always fsync each write and thus are
|
||||
really slow when used with desktop SSDs. Vitastor, however, can also
|
||||
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
||||
it explicitly.
|
||||
|
||||
This is what this parameter regulates. When it's set to "all" the whole
|
||||
Vitastor cluster commits each change to disks immediately and clients just
|
||||
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
||||
the amount of network roundtrips performed by clients and improves
|
||||
performance. So it's always better to use server grade SSDs with
|
||||
supercapacitors even with Vitastor, especially given that they cost only
|
||||
a bit more than desktop models.
|
||||
|
||||
There is also a common SATA SSD (and HDD too!) firmware bug (or feature)
|
||||
that makes server SSDs which have supercapacitors slow with fsync. To check
|
||||
if your SSDs are affected, compare benchmark results from `fio -name=test
|
||||
-ioengine=libaio -direct=1 -bs=4k -rw=randwrite -iodepth=1` with and without
|
||||
`-fsync=1`. Results should be the same. If fsync=1 result is worse you can
|
||||
try to work around this bug by "disabling" drive write-back cache by running
|
||||
`hdparm -W 0 /dev/sdXX` or `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
|
||||
(IMPORTANT: don't mistake it with `/sys/block/sdXX/queue/write_cache` - it's
|
||||
unsafe to change by hand). The same may apply to newer HDDs with internal
|
||||
SSD cache or "media-cache" - for example, a lot of Seagate EXOS drives have
|
||||
it (they have internal SSD cache even though it's not stated in datasheets).
|
||||
|
||||
This parameter must be set both in etcd in /vitastor/config/global and in
|
||||
OSD command line or configuration. Setting it to "all" or "small" requires
|
||||
enabling disable_journal_fsync and disable_meta_fsync, setting it to "all"
|
||||
also requires enabling disable_data_fsync.
|
||||
|
||||
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
||||
SSDs with supercapacitor-based power loss protection (nonvolatile
|
||||
write-through cache) for both data and journals in the whole Vitastor
|
||||
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
||||
empty if your drives have write-back cache.
|
||||
|
||||
## client_dirty_limit
|
||||
|
||||
- Type: integer
|
||||
- Default: 33554432
|
||||
|
||||
Without immediate_commit=all this parameter sets the limit of "dirty"
|
||||
(not committed by fsync) data allowed by the client before forcing an
|
||||
additional fsync and committing the data. Also note that the client always
|
||||
holds a copy of uncommitted data in memory so this setting also affects
|
||||
RAM usage of clients.
|
||||
|
||||
This parameter doesn't affect OSDs themselves.
|
|
@ -1,134 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Дисковые параметры уровня кластера
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](layout-cluster.en.md)
|
||||
|
||||
# Дисковые параметры уровня кластера
|
||||
|
||||
Данные параметры используются клиентами и OSD, задаются в момент инициализации
|
||||
диска OSD и не могут быть изменены после этого без потери данных.
|
||||
|
||||
- [block_size](#block_size)
|
||||
- [bitmap_granularity](#bitmap_granularity)
|
||||
- [immediate_commit](#immediate_commit)
|
||||
- [client_dirty_limit](#client_dirty_limit)
|
||||
|
||||
## block_size
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 131072
|
||||
|
||||
Размер объектов (блоков данных), на которые делятся физические и виртуальные
|
||||
диски в Vitastor. Одна из ключевых на данный момент настроек, влияет на
|
||||
потребление памяти, объём избыточной записи (write amplification) и
|
||||
эффективность распределения нагрузки по OSD.
|
||||
|
||||
Рекомендуемые по умолчанию размеры блока - 128 килобайт для SSD и 4
|
||||
мегабайта для HDD. В принципе, для SSD можно тоже использовать 4 мегабайта,
|
||||
это понизит использование памяти, но ухудшит распределение нагрузки и в
|
||||
среднем увеличит WA.
|
||||
|
||||
OSD с разными размерами блока (например, SSD и SSD+HDD OSD) на данный
|
||||
момент могут сосуществовать в рамках одного etcd только в виде двух независимых
|
||||
кластеров Vitastor с разными etcd_prefix.
|
||||
|
||||
Также размер блока нельзя менять после инициализации OSD без потери данных.
|
||||
|
||||
Если вы меняете размер блока, обязательно прописывайте его в etcd в
|
||||
/vitastor/config/global, дабы все клиенты его знали.
|
||||
|
||||
Потребление памяти OSD составляет примерно (РАЗМЕР / БЛОК * 68 байт),
|
||||
т.е. примерно 544 МБ памяти на 1 ТБ занятого места на диске при
|
||||
стандартном 128 КБ блоке.
|
||||
|
||||
## bitmap_granularity
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4096
|
||||
|
||||
Требуемое выравнивание записи на виртуальные диски (размер их "сектора").
|
||||
Должен быть кратен disk_alignment. Называется гранулярностью битовой карты
|
||||
потому, что Vitastor хранит битовую карту для каждого объекта, содержащую
|
||||
по 2 бита на каждые (bitmap_granularity) байт.
|
||||
|
||||
Данный параметр нельзя менять после инициализации OSD без потери данных.
|
||||
Также он фиксирован для всего кластера Vitastor, т.е. разные значения
|
||||
не могут сосуществовать в одном кластере.
|
||||
|
||||
Клиенты ДОЛЖНЫ знать правильное значение этого параметра, так что если вы
|
||||
его меняете, обязательно прописывайте изменённое значение в etcd в ключ
|
||||
/vitastor/config/global.
|
||||
|
||||
## immediate_commit
|
||||
|
||||
- Тип: строка
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Ещё один важный для производительности параметр.
|
||||
|
||||
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
||||
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
||||
медленные (всего порядка 1000 iops), если вы пытаетесь сбрасывать кэш после
|
||||
каждой записи, то есть, если вы пытаетесь гарантировать, что каждое
|
||||
изменение физически записывается в энергонезависимую память.
|
||||
|
||||
С другой стороны, серверные SSD с конденсаторами - функцией, называемой
|
||||
"Advanced/Enhanced Power Loss Protection" или просто "Supercapacitor-based
|
||||
Power Loss Protection" - одинаково быстрые и со сбросом кэша, и без
|
||||
него, потому что их кэш защищён от потери питания встроенным "источником
|
||||
бесперебойного питания" на основе суперконденсаторов и на самом деле они
|
||||
его никогда не сбрасывают.
|
||||
|
||||
Некоторые программные СХД всегда сбрасывают кэши дисков при каждой записи
|
||||
и поэтому работают очень медленно с настольными SSD. Vitastor, однако, может
|
||||
откладывать fsync до явного его вызова со стороны клиента и таким образом
|
||||
эффективно утилизировать настольные SSD.
|
||||
|
||||
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
||||
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
||||
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
||||
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
||||
использовать только серверные модели SSD с суперконденсаторами, особенно
|
||||
учитывая то, что стоят они ненамного дороже настольных.
|
||||
|
||||
Также в прошивках SATA SSD (и даже HDD!) очень часто встречается либо баг,
|
||||
либо просто особенность логики, из-за которой серверные SSD, имеющие
|
||||
конденсаторы и защиту от потери питания, всё равно медленно работают с
|
||||
fsync. Чтобы понять, подвержены ли этой проблеме ваши SSD, сравните
|
||||
результаты тестов `fio -name=test -ioengine=libaio -direct=1 -bs=4k
|
||||
-rw=randwrite -iodepth=1` без и с опцией `-fsync=1`. Результаты должны
|
||||
быть одинаковые. Если результат с `fsync=1` хуже, вы можете попробовать
|
||||
обойти проблему, "отключив" кэш записи диска командой `hdparm -W 0 /dev/sdXX`
|
||||
либо `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
|
||||
(ВАЖНО: не перепутайте с `/sys/block/sdXX/queue/write_cache` - этот параметр
|
||||
менять руками небезопасно). Такая же проблема может встречаться и в новых
|
||||
HDD-дисках с внутренним SSD или "медиа" кэшем - например, она встречается во
|
||||
многих дисках Seagate EXOS (у них есть внутренний SSD-кэш, хотя это и не
|
||||
указано в спецификациях).
|
||||
|
||||
Данный параметр нужно указывать и в etcd в /vitastor/config/global, и в
|
||||
командной строке или конфигурации OSD. Значения "all" и "small" требуют
|
||||
включения disable_journal_fsync и disable_meta_fsync, значение "all" также
|
||||
требует включения disable_data_fsync.
|
||||
|
||||
Итого, вкратце: для оптимальной производительности установите
|
||||
immediate_commit в значение "all", если вы используете в кластере только SSD
|
||||
с суперконденсаторами и для данных, и для журналов. Если вы используете
|
||||
такие SSD для всех журналов, но не для данных - можете установить параметр
|
||||
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
|
||||
оставьте параметр пустым.
|
||||
|
||||
## client_dirty_limit
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 33554432
|
||||
|
||||
При работе без immediate_commit=all - это лимит объёма "грязных" (не
|
||||
зафиксированных fsync-ом) данных, при достижении которого клиент будет
|
||||
принудительно вызывать fsync и фиксировать данные. Также стоит иметь в виду,
|
||||
что в этом случае до момента fsync клиент хранит копию незафиксированных
|
||||
данных в памяти, то есть, настройка влияет на потребление памяти клиентами.
|
||||
|
||||
Параметр не влияет на сами OSD.
|
|
@ -1,176 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → OSD Disk Layout Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](layout-osd.ru.md)
|
||||
|
||||
# OSD Disk Layout Parameters
|
||||
|
||||
These parameters apply to OSDs, are fixed at the moment of OSD drive
|
||||
initialization and can't be changed after it without losing data.
|
||||
|
||||
- [data_device](#data_device)
|
||||
- [meta_device](#meta_device)
|
||||
- [journal_device](#journal_device)
|
||||
- [journal_offset](#journal_offset)
|
||||
- [journal_size](#journal_size)
|
||||
- [meta_offset](#meta_offset)
|
||||
- [data_offset](#data_offset)
|
||||
- [data_size](#data_size)
|
||||
- [meta_block_size](#meta_block_size)
|
||||
- [journal_block_size](#journal_block_size)
|
||||
- [disable_data_fsync](#disable_data_fsync)
|
||||
- [disable_meta_fsync](#disable_meta_fsync)
|
||||
- [disable_journal_fsync](#disable_journal_fsync)
|
||||
- [disable_device_lock](#disable_device_lock)
|
||||
- [disk_alignment](#disk_alignment)
|
||||
|
||||
## data_device
|
||||
|
||||
- Type: string
|
||||
|
||||
Path to the block device to use for data. It's highly recommendded to use
|
||||
stable paths for all device names: `/dev/disk/by-partuuid/xxx...` instead
|
||||
of just `/dev/sda` or `/dev/nvme0n1` to not mess up after server restart.
|
||||
Files can also be used instead of block devices, but this is implemented
|
||||
only for testing purposes and not for production.
|
||||
|
||||
## meta_device
|
||||
|
||||
- Type: string
|
||||
|
||||
Path to the block device to use for the metadata. Metadata must be on a fast
|
||||
SSD or performance will suffer. If this option is skipped, `data_device` is
|
||||
used for the metadata.
|
||||
|
||||
## journal_device
|
||||
|
||||
- Type: string
|
||||
|
||||
Path to the block device to use for the journal. Journal must be on a fast
|
||||
SSD or performance will suffer. If this option is skipped, `meta_device` is
|
||||
used for the journal, and if it's also empty, journal is put on
|
||||
`data_device`. It's almost always fine to put metadata and journal on the
|
||||
same device, in this case you only need to set `meta_device`.
|
||||
|
||||
## journal_offset
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Offset on the device in bytes where the journal is stored.
|
||||
|
||||
## journal_size
|
||||
|
||||
- Type: integer
|
||||
|
||||
Journal size in bytes. By default, all available space between journal_offset
|
||||
and data_offset, meta_offset or the end of the journal device is used.
|
||||
Large journals aren't needed in SSD-only setups, 32 MB is always enough.
|
||||
In SSD+HDD setups it is beneficial to use larger journals (for example, 1 GB)
|
||||
and enable [throttle_small_writes](osd.en.md#throttle_small_writes).
|
||||
|
||||
## meta_offset
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Offset on the device in bytes where the metadata area is stored.
|
||||
Again, set it to something if you colocate metadata with journal or data.
|
||||
|
||||
## data_offset
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Offset on the device in bytes where the data area is stored.
|
||||
Again, set it to something if you colocate data with journal or metadata.
|
||||
|
||||
## data_size
|
||||
|
||||
- Type: integer
|
||||
|
||||
Data area size in bytes. By default, the whole data device up to the end
|
||||
will be used for the data area, but you can restrict it if you want to use
|
||||
a smaller part. Note that there is no option to set metadata area size -
|
||||
it's derived from the data area size.
|
||||
|
||||
## meta_block_size
|
||||
|
||||
- Type: integer
|
||||
- Default: 4096
|
||||
|
||||
Physical block size of the metadata device. 4096 for most current
|
||||
HDDs and SSDs.
|
||||
|
||||
## journal_block_size
|
||||
|
||||
- Type: integer
|
||||
- Default: 4096
|
||||
|
||||
Physical block size of the journal device. Must be a multiple of
|
||||
`disk_alignment`. 4096 for most current HDDs and SSDs.
|
||||
|
||||
## disable_data_fsync
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Do not issue fsyncs to the data device, i.e. do not flush its cache.
|
||||
Safe ONLY if your data device has write-through cache. If you disable
|
||||
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure
|
||||
that the cache disable command is run every time before starting Vitastor
|
||||
OSD, for example, in the systemd unit. See also `immediate_commit` option
|
||||
for the instructions to disable cache and how to benefit from it.
|
||||
|
||||
## disable_meta_fsync
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Same as disable_data_fsync, but for the metadata device. If the metadata
|
||||
device is not set or if the data device is used for the metadata the option
|
||||
is ignored and disable_data_fsync value is used instead of it.
|
||||
|
||||
## disable_journal_fsync
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Same as disable_data_fsync, but for the journal device. If the journal
|
||||
device is not set or if the metadata device is used for the journal the
|
||||
option is ignored and disable_meta_fsync value is used instead of it. If
|
||||
the same device is used for data, metadata and journal the option is also
|
||||
ignored and disable_data_fsync value is used instead of it.
|
||||
|
||||
## disable_device_lock
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Do not lock data, metadata and journal block devices exclusively with
|
||||
flock(). Though it's not recommended, but you can use it you want to run
|
||||
multiple OSD with a single device and different offsets, without using
|
||||
partitions.
|
||||
|
||||
## disk_alignment
|
||||
|
||||
- Type: integer
|
||||
- Default: 4096
|
||||
|
||||
Required physical disk write alignment. Most current SSD and HDD drives
|
||||
use 4 KB physical sectors even if they report 512 byte logical sector
|
||||
size, so 4 KB is a good default setting.
|
||||
|
||||
Note, however, that physical sector size also affects WA, because with block
|
||||
devices it's impossible to write anything smaller than a block. So, when
|
||||
Vitastor has to write a single metadata entry that's only about 32 bytes in
|
||||
size, it actually has to write the whole 4 KB sector.
|
||||
|
||||
Because of this it can actually be beneficial to use SSDs which work well
|
||||
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
|
||||
and meta_block_size. But the only SSD that may fit into this category is
|
||||
Intel Optane (probably, not tested yet).
|
||||
|
||||
Clients don't need to be aware of disk_alignment, so it's not required to
|
||||
put a modified value into etcd key /vitastor/config/global.
|
|
@ -1,185 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Дисковые параметры OSD
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](layout-osd.en.md)
|
||||
|
||||
# Дисковые параметры OSD
|
||||
|
||||
Данные параметры используются только OSD и, также как и общекластерные
|
||||
дисковые параметры, задаются в момент инициализации дисков OSD и не могут быть
|
||||
изменены после этого без потери данных.
|
||||
|
||||
- [data_device](#data_device)
|
||||
- [meta_device](#meta_device)
|
||||
- [journal_device](#journal_device)
|
||||
- [journal_offset](#journal_offset)
|
||||
- [journal_size](#journal_size)
|
||||
- [meta_offset](#meta_offset)
|
||||
- [data_offset](#data_offset)
|
||||
- [data_size](#data_size)
|
||||
- [meta_block_size](#meta_block_size)
|
||||
- [journal_block_size](#journal_block_size)
|
||||
- [disable_data_fsync](#disable_data_fsync)
|
||||
- [disable_meta_fsync](#disable_meta_fsync)
|
||||
- [disable_journal_fsync](#disable_journal_fsync)
|
||||
- [disable_device_lock](#disable_device_lock)
|
||||
- [disk_alignment](#disk_alignment)
|
||||
|
||||
## data_device
|
||||
|
||||
- Тип: строка
|
||||
|
||||
Путь к диску (блочному устройству) для хранения данных. Крайне рекомендуется
|
||||
использовать стабильные пути: `/dev/disk/by-partuuid/xxx...` вместо простых
|
||||
`/dev/sda` или `/dev/nvme0n1`, чтобы пути не могли спутаться после
|
||||
перезагрузки сервера. Также вместо блочных устройств можно указывать файлы,
|
||||
но это реализовано только для тестирования, а не для боевой среды.
|
||||
|
||||
## meta_device
|
||||
|
||||
- Тип: строка
|
||||
|
||||
Путь к диску метаданных. Метаданные должны располагаться на быстром
|
||||
SSD-диске, иначе производительность пострадает. Если эта опция не указана,
|
||||
для метаданных используется `data_device`.
|
||||
|
||||
## journal_device
|
||||
|
||||
- Тип: строка
|
||||
|
||||
Путь к диску журнала. Журнал должен располагаться на быстром SSD-диске,
|
||||
иначе производительность пострадает. Если эта опция не указана,
|
||||
для журнала используется `meta_device`, если же пуста и она, журнал
|
||||
располагается на `data_device`. Нормально располагать журнал и метаданные
|
||||
на одном устройстве, в этом случае достаточно указать только `meta_device`.
|
||||
|
||||
## journal_offset
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 0
|
||||
|
||||
Смещение на устройстве в байтах, по которому располагается журнал.
|
||||
|
||||
## journal_size
|
||||
|
||||
- Тип: целое число
|
||||
|
||||
Размер журнала в байтах. По умолчанию для журнала используется всё доступное
|
||||
место между journal_offset и data_offset, meta_offset или концом диска.
|
||||
В SSD-кластерах большие журналы не нужны, достаточно 32 МБ. В гибридных
|
||||
(SSD+HDD) кластерах осмысленно использовать больший размер журнал (например, 1 ГБ)
|
||||
и включить [throttle_small_writes](osd.ru.md#throttle_small_writes).
|
||||
|
||||
## meta_offset
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 0
|
||||
|
||||
Смещение на устройстве в байтах, по которому располагаются метаданные.
|
||||
Эту опцию нужно задать, если метаданные у вас хранятся на том же
|
||||
устройстве, что данные или журнал.
|
||||
|
||||
## data_offset
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 0
|
||||
|
||||
Смещение на устройстве в байтах, по которому располагаются данные.
|
||||
Эту опцию нужно задать, если данные у вас хранятся на том же
|
||||
устройстве, что метаданные или журнал.
|
||||
|
||||
## data_size
|
||||
|
||||
- Тип: целое число
|
||||
|
||||
Размер области данных в байтах. По умолчанию под данные будет использована
|
||||
вся доступная область устройства данных до конца устройства, но вы можете
|
||||
использовать эту опцию, чтобы ограничить её меньшим размером. Заметьте, что
|
||||
опции размера области метаданных нет - она вычисляется из размера области
|
||||
данных автоматически.
|
||||
|
||||
## meta_block_size
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4096
|
||||
|
||||
Размер физического блока устройства метаданных. 4096 для большинства
|
||||
современных SSD и HDD.
|
||||
|
||||
## journal_block_size
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4096
|
||||
|
||||
Размер физического блока устройства журнала. Должен быть кратен
|
||||
`disk_alignment`. 4096 для большинства современных SSD и HDD.
|
||||
|
||||
## disable_data_fsync
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш.
|
||||
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
|
||||
записью (write-through). Если вы отключаете кэш через `hdparm` или
|
||||
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша
|
||||
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е.
|
||||
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша
|
||||
и о том, как из этого извлечь выгоду.
|
||||
|
||||
## disable_meta_fsync
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
То же, что disable_data_fsync, но для устройства метаданных. Если устройство
|
||||
метаданных не задано или если оно равно устройству данных, значение опции
|
||||
игнорируется и вместо него используется значение опции disable_data_fsync.
|
||||
|
||||
## disable_journal_fsync
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
То же, что disable_data_fsync, но для устройства журнала. Если устройство
|
||||
журнала не задано или если оно равно устройству метаданных, значение опции
|
||||
игнорируется и вместо него используется значение опции disable_meta_fsync.
|
||||
Если одно и то же устройство используется и под данные, и под журнал, и под
|
||||
метаданные - значение опции также игнорируется и вместо него используется
|
||||
значение опции disable_data_fsync.
|
||||
|
||||
## disable_device_lock
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Не блокировать устройства данных, метаданных и журнала от открытия их
|
||||
другими OSD с помощью flock(). Так делать не рекомендуется, но теоретически
|
||||
вы можете это использовать, чтобы запускать несколько OSD на одном
|
||||
устройстве с разными смещениями и без использования разделов.
|
||||
|
||||
## disk_alignment
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4096
|
||||
|
||||
Требуемое выравнивание записи на физические диски. Почти все современные
|
||||
SSD и HDD диски используют 4 КБ физические секторы, даже если показывают
|
||||
логический размер сектора 512 байт, поэтому 4 КБ - хорошее значение по
|
||||
умолчанию.
|
||||
|
||||
Однако стоит понимать, что физический размер сектора тоже влияет на
|
||||
избыточную запись (WA), потому что ничего меньше блока (сектора) на блочное
|
||||
устройство записать невозможно. Таким образом, когда Vitastor-у нужно
|
||||
записать на диск всего лишь одну 32-байтную запись метаданных, фактически
|
||||
приходится перезаписывать 4 КБ сектор целиком.
|
||||
|
||||
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
|
||||
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
|
||||
journal_block_size и meta_block_size. Однако единственные SSD, которые
|
||||
теоретически могут попасть в эту категорию - это Intel Optane (но и это
|
||||
пока не проверялось автором).
|
||||
|
||||
Клиентам не обязательно знать про disk_alignment, так что помещать значение
|
||||
этого параметра в etcd в /vitastor/config/global не нужно.
|
|
@ -1,79 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Monitor Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](monitor.ru.md)
|
||||
|
||||
# Monitor Parameters
|
||||
|
||||
These parameters only apply to Monitors.
|
||||
|
||||
- [etcd_mon_ttl](#etcd_mon_ttl)
|
||||
- [etcd_mon_timeout](#etcd_mon_timeout)
|
||||
- [etcd_mon_retries](#etcd_mon_retries)
|
||||
- [mon_change_timeout](#mon_change_timeout)
|
||||
- [mon_stats_timeout](#mon_stats_timeout)
|
||||
- [osd_out_time](#osd_out_time)
|
||||
- [placement_levels](#placement_levels)
|
||||
|
||||
## etcd_mon_ttl
|
||||
|
||||
- Type: seconds
|
||||
- Default: 30
|
||||
- Minimum: 10
|
||||
|
||||
Monitor etcd lease refresh interval in seconds
|
||||
|
||||
## etcd_mon_timeout
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 1000
|
||||
|
||||
etcd request timeout used by monitor
|
||||
|
||||
## etcd_mon_retries
|
||||
|
||||
- Type: integer
|
||||
- Default: 5
|
||||
|
||||
Maximum number of attempts for one monitor etcd request
|
||||
|
||||
## mon_change_timeout
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 1000
|
||||
- Minimum: 100
|
||||
|
||||
Optimistic retry interval for monitor etcd modification requests
|
||||
|
||||
## mon_stats_timeout
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 1000
|
||||
- Minimum: 100
|
||||
|
||||
Interval for monitor to wait before updating aggregated statistics in
|
||||
etcd after receiving OSD statistics updates
|
||||
|
||||
## osd_out_time
|
||||
|
||||
- Type: seconds
|
||||
- Default: 600
|
||||
|
||||
Time after which a failed OSD is removed from the data distribution.
|
||||
I.e. time which the monitor waits before attempting to restore data
|
||||
redundancy using other OSDs.
|
||||
|
||||
## placement_levels
|
||||
|
||||
- Type: json
|
||||
- Default: `{"host":100,"osd":101}`
|
||||
|
||||
Levels for the placement tree. You can define arbitrary tree levels by
|
||||
defining them in this parameter. The configuration parameter value should
|
||||
contain a JSON object with level names as keys and integer priorities as
|
||||
values. Smaller priority means higher level in tree. For example,
|
||||
"datacenter" should have smaller priority than "osd". "host" and "osd"
|
||||
levels are always predefined and can't be removed. If one of them is not
|
||||
present in the configuration, then it is defined with the default priority
|
||||
(100 for "host", 101 for "osd").
|
|
@ -1,80 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Параметры мониторов
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](monitor.en.md)
|
||||
|
||||
# Параметры мониторов
|
||||
|
||||
Данные параметры используются только мониторами Vitastor.
|
||||
|
||||
- [etcd_mon_ttl](#etcd_mon_ttl)
|
||||
- [etcd_mon_timeout](#etcd_mon_timeout)
|
||||
- [etcd_mon_retries](#etcd_mon_retries)
|
||||
- [mon_change_timeout](#mon_change_timeout)
|
||||
- [mon_stats_timeout](#mon_stats_timeout)
|
||||
- [osd_out_time](#osd_out_time)
|
||||
- [placement_levels](#placement_levels)
|
||||
|
||||
## etcd_mon_ttl
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 30
|
||||
- Минимальное значение: 10
|
||||
|
||||
Интервал обновления etcd резервации (lease) монитором
|
||||
|
||||
## etcd_mon_timeout
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 1000
|
||||
|
||||
Таймаут выполнения запросов к etcd от монитора
|
||||
|
||||
## etcd_mon_retries
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 5
|
||||
|
||||
Максимальное число попыток выполнения запросов к etcd монитором
|
||||
|
||||
## mon_change_timeout
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 1000
|
||||
- Минимальное значение: 100
|
||||
|
||||
Время повтора при коллизиях при запросах модификации в etcd, производимых монитором
|
||||
|
||||
## mon_stats_timeout
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 1000
|
||||
- Минимальное значение: 100
|
||||
|
||||
Интервал, который монитор ожидает при изменении статистики по отдельным
|
||||
OSD перед обновлением агрегированной статистики в etcd
|
||||
|
||||
## osd_out_time
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 600
|
||||
|
||||
Время, через которое отключенный OSD исключается из распределения данных.
|
||||
То есть, время, которое монитор ожидает перед попыткой переместить данные
|
||||
на другие OSD и таким образом восстановить избыточность хранения.
|
||||
|
||||
## placement_levels
|
||||
|
||||
- Тип: json
|
||||
- Значение по умолчанию: `{"host":100,"osd":101}`
|
||||
|
||||
Определения уровней для дерева размещения OSD. Вы можете определять
|
||||
произвольные уровни, помещая их в данный параметр конфигурации. Значение
|
||||
параметра должно содержать JSON-объект, ключи которого будут являться
|
||||
названиями уровней, а значения - целочисленными приоритетами. Меньшие
|
||||
приоритеты соответствуют верхним уровням дерева. Например, уровень
|
||||
"датацентр" должен иметь меньший приоритет, чем "OSD". Уровни с названиями
|
||||
"host" и "osd" являются предопределёнными и не могут быть удалены. Если
|
||||
один из них отсутствует в конфигурации, он доопределяется с приоритетом по
|
||||
умолчанию (100 для уровня "host", 101 для "osd").
|
|
@ -1,214 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Network Protocol Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](network.ru.md)
|
||||
|
||||
# Network Protocol Parameters
|
||||
|
||||
These parameters apply to clients and OSDs and affect network connection logic
|
||||
between clients, OSDs and etcd.
|
||||
|
||||
- [tcp_header_buffer_size](#tcp_header_buffer_size)
|
||||
- [use_sync_send_recv](#use_sync_send_recv)
|
||||
- [use_rdma](#use_rdma)
|
||||
- [rdma_device](#rdma_device)
|
||||
- [rdma_port_num](#rdma_port_num)
|
||||
- [rdma_gid_index](#rdma_gid_index)
|
||||
- [rdma_mtu](#rdma_mtu)
|
||||
- [rdma_max_sge](#rdma_max_sge)
|
||||
- [rdma_max_msg](#rdma_max_msg)
|
||||
- [rdma_max_recv](#rdma_max_recv)
|
||||
- [peer_connect_interval](#peer_connect_interval)
|
||||
- [peer_connect_timeout](#peer_connect_timeout)
|
||||
- [osd_idle_timeout](#osd_idle_timeout)
|
||||
- [osd_ping_timeout](#osd_ping_timeout)
|
||||
- [up_wait_retry_interval](#up_wait_retry_interval)
|
||||
- [max_etcd_attempts](#max_etcd_attempts)
|
||||
- [etcd_quick_timeout](#etcd_quick_timeout)
|
||||
- [etcd_slow_timeout](#etcd_slow_timeout)
|
||||
- [etcd_keepalive_timeout](#etcd_keepalive_timeout)
|
||||
- [etcd_ws_keepalive_timeout](#etcd_ws_keepalive_timeout)
|
||||
|
||||
## tcp_header_buffer_size
|
||||
|
||||
- Type: integer
|
||||
- Default: 65536
|
||||
|
||||
Size of the buffer used to read data using an additional copy. Vitastor
|
||||
packet headers are 128 bytes, payload is always at least 4 KB, so it is
|
||||
usually beneficial to try to read multiple packets at once even though
|
||||
it requires to copy the data an additional time. The rest of each packet
|
||||
is received without an additional copy. You can try to play with this
|
||||
parameter and see how it affects random iops and linear bandwidth if you
|
||||
want.
|
||||
|
||||
## use_sync_send_recv
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
If true, synchronous send/recv syscalls are used instead of io_uring for
|
||||
socket communication. Useless for OSDs because they require io_uring anyway,
|
||||
but may be required for clients with old kernel versions.
|
||||
|
||||
## use_rdma
|
||||
|
||||
- Type: boolean
|
||||
- Default: true
|
||||
|
||||
Try to use RDMA for communication if it's available. Disable if you don't
|
||||
want Vitastor to use RDMA. TCP-only clients can also talk to an RDMA-enabled
|
||||
cluster, so disabling RDMA may be needed if clients have RDMA devices,
|
||||
but they are not connected to the cluster.
|
||||
|
||||
## rdma_device
|
||||
|
||||
- Type: string
|
||||
|
||||
RDMA device name to use for Vitastor OSD communications (for example,
|
||||
"rocep5s0f0"). Please note that Vitastor RDMA requires Implicit On-Demand
|
||||
Paging (Implicit ODP) and Scatter/Gather (SG) support from the RDMA device
|
||||
to work. For example, Mellanox ConnectX-3 and older adapters don't have
|
||||
Implicit ODP, so they're unsupported by Vitastor. Run `ibv_devinfo -v` as
|
||||
root to list available RDMA devices and their features.
|
||||
|
||||
## rdma_port_num
|
||||
|
||||
- Type: integer
|
||||
- Default: 1
|
||||
|
||||
RDMA device port number to use. Only for devices that have more than 1 port.
|
||||
See `phys_port_cnt` in `ibv_devinfo -v` output to determine how many ports
|
||||
your device has.
|
||||
|
||||
## rdma_gid_index
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Global address identifier index of the RDMA device to use. Different GID
|
||||
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
|
||||
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
|
||||
you need.
|
||||
|
||||
**IMPORTANT:** If you want to use RoCEv2 (as recommended) then the correct
|
||||
rdma_gid_index is usually 1 (IPv6) or 3 (IPv4).
|
||||
|
||||
## rdma_mtu
|
||||
|
||||
- Type: integer
|
||||
- Default: 4096
|
||||
|
||||
RDMA Path MTU to use. Must be 1024, 2048 or 4096. There is usually no
|
||||
sense to change it from the default 4096.
|
||||
|
||||
## rdma_max_sge
|
||||
|
||||
- Type: integer
|
||||
- Default: 128
|
||||
|
||||
Maximum number of scatter/gather entries to use for RDMA. OSDs negotiate
|
||||
the actual value when establishing connection anyway, so it's usually not
|
||||
required to change this parameter.
|
||||
|
||||
## rdma_max_msg
|
||||
|
||||
- Type: integer
|
||||
- Default: 1048576
|
||||
|
||||
Maximum size of a single RDMA send or receive operation in bytes.
|
||||
|
||||
## rdma_max_recv
|
||||
|
||||
- Type: integer
|
||||
- Default: 8
|
||||
|
||||
Maximum number of parallel RDMA receive operations. Note that this number
|
||||
of receive buffers `rdma_max_msg` in size are allocated for each client,
|
||||
so this setting actually affects memory usage. This is because RDMA receive
|
||||
operations are (sadly) still not zero-copy in Vitastor. It may be fixed in
|
||||
later versions.
|
||||
|
||||
## peer_connect_interval
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
- Minimum: 1
|
||||
|
||||
Interval before attempting to reconnect to an unavailable OSD.
|
||||
|
||||
## peer_connect_timeout
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
- Minimum: 1
|
||||
|
||||
Timeout for OSD connection attempts.
|
||||
|
||||
## osd_idle_timeout
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
- Minimum: 1
|
||||
|
||||
OSD connection inactivity time after which clients and other OSDs send
|
||||
keepalive requests to check state of the connection.
|
||||
|
||||
## osd_ping_timeout
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
- Minimum: 1
|
||||
|
||||
Maximum time to wait for OSD keepalive responses. If an OSD doesn't respond
|
||||
within this time, the connection to it is dropped and a reconnection attempt
|
||||
is scheduled.
|
||||
|
||||
## up_wait_retry_interval
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 500
|
||||
- Minimum: 50
|
||||
|
||||
OSDs respond to clients with a special error code when they receive I/O
|
||||
requests for a PG that's not synchronized and started. This parameter sets
|
||||
the time for the clients to wait before re-attempting such I/O requests.
|
||||
|
||||
## max_etcd_attempts
|
||||
|
||||
- Type: integer
|
||||
- Default: 5
|
||||
|
||||
Maximum number of attempts for etcd requests which can't be retried
|
||||
indefinitely.
|
||||
|
||||
## etcd_quick_timeout
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 1000
|
||||
|
||||
Timeout for etcd requests which should complete quickly, like lease refresh.
|
||||
|
||||
## etcd_slow_timeout
|
||||
|
||||
- Type: milliseconds
|
||||
- Default: 5000
|
||||
|
||||
Timeout for etcd requests which are allowed to wait for some time.
|
||||
|
||||
## etcd_keepalive_timeout
|
||||
|
||||
- Type: seconds
|
||||
- Default: max(30, etcd_report_interval*2)
|
||||
|
||||
Timeout for etcd connection HTTP Keep-Alive. Should be higher than
|
||||
etcd_report_interval to guarantee that keepalive actually works.
|
||||
|
||||
## etcd_ws_keepalive_timeout
|
||||
|
||||
- Type: seconds
|
||||
- Default: 30
|
||||
|
||||
etcd websocket ping interval required to keep the connection alive and
|
||||
detect disconnections quickly.
|
|
@ -1,224 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Параметры сетевого протокола
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](network.en.md)
|
||||
|
||||
# Параметры сетевого протокола
|
||||
|
||||
Данные параметры используются клиентами и OSD и влияют на логику сетевого
|
||||
взаимодействия между клиентами, OSD, а также etcd.
|
||||
|
||||
- [tcp_header_buffer_size](#tcp_header_buffer_size)
|
||||
- [use_sync_send_recv](#use_sync_send_recv)
|
||||
- [use_rdma](#use_rdma)
|
||||
- [rdma_device](#rdma_device)
|
||||
- [rdma_port_num](#rdma_port_num)
|
||||
- [rdma_gid_index](#rdma_gid_index)
|
||||
- [rdma_mtu](#rdma_mtu)
|
||||
- [rdma_max_sge](#rdma_max_sge)
|
||||
- [rdma_max_msg](#rdma_max_msg)
|
||||
- [rdma_max_recv](#rdma_max_recv)
|
||||
- [peer_connect_interval](#peer_connect_interval)
|
||||
- [peer_connect_timeout](#peer_connect_timeout)
|
||||
- [osd_idle_timeout](#osd_idle_timeout)
|
||||
- [osd_ping_timeout](#osd_ping_timeout)
|
||||
- [up_wait_retry_interval](#up_wait_retry_interval)
|
||||
- [max_etcd_attempts](#max_etcd_attempts)
|
||||
- [etcd_quick_timeout](#etcd_quick_timeout)
|
||||
- [etcd_slow_timeout](#etcd_slow_timeout)
|
||||
- [etcd_keepalive_timeout](#etcd_keepalive_timeout)
|
||||
- [etcd_ws_keepalive_timeout](#etcd_ws_keepalive_timeout)
|
||||
|
||||
## tcp_header_buffer_size
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 65536
|
||||
|
||||
Размер буфера для чтения данных с дополнительным копированием. Пакеты
|
||||
Vitastor содержат 128-байтные заголовки, за которыми следуют данные размером
|
||||
от 4 КБ и для мелких операций ввода-вывода обычно выгодно за 1 вызов читать
|
||||
сразу несколько пакетов, даже не смотря на то, что это требует лишний раз
|
||||
скопировать данные. Часть каждого пакета за пределами значения данного
|
||||
параметра читается без дополнительного копирования. Вы можете попробовать
|
||||
поменять этот параметр и посмотреть, как он влияет на производительность
|
||||
случайного и линейного доступа.
|
||||
|
||||
## use_sync_send_recv
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Если установлено в истину, то вместо io_uring для передачи данных по сети
|
||||
будут использоваться обычные синхронные системные вызовы send/recv. Для OSD
|
||||
это бессмысленно, так как OSD в любом случае нуждается в io_uring, но, в
|
||||
принципе, это может применяться для клиентов со старыми версиями ядра.
|
||||
|
||||
## use_rdma
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: true
|
||||
|
||||
Пытаться использовать RDMA для связи при наличии доступных устройств.
|
||||
Отключите, если вы не хотите, чтобы Vitastor использовал RDMA.
|
||||
TCP-клиенты также могут работать с RDMA-кластером, так что отключать
|
||||
RDMA может быть нужно только если у клиентов есть RDMA-устройства,
|
||||
но они не имеют соединения с кластером Vitastor.
|
||||
|
||||
## rdma_device
|
||||
|
||||
- Тип: строка
|
||||
|
||||
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
|
||||
Имейте в виду, что поддержка RDMA в Vitastor требует функций устройства
|
||||
Implicit On-Demand Paging (Implicit ODP) и Scatter/Gather (SG). Например,
|
||||
адаптеры Mellanox ConnectX-3 и более старые не поддерживают Implicit ODP и
|
||||
потому не поддерживаются в Vitastor. Запустите `ibv_devinfo -v` от имени
|
||||
суперпользователя, чтобы посмотреть список доступных RDMA-устройств, их
|
||||
параметры и возможности.
|
||||
|
||||
## rdma_port_num
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 1
|
||||
|
||||
Номер порта RDMA-устройства, который следует использовать. Имеет смысл
|
||||
только для устройств, у которых более 1 порта. Чтобы узнать, сколько портов
|
||||
у вашего адаптера, посмотрите `phys_port_cnt` в выводе команды
|
||||
`ibv_devinfo -v`.
|
||||
|
||||
## rdma_gid_index
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 0
|
||||
|
||||
Номер глобального идентификатора адреса RDMA-устройства, который следует
|
||||
использовать. Разным gid_index могут соответствовать разные протоколы связи:
|
||||
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
|
||||
словом "GID" в выводе команды `ibv_devinfo -v`.
|
||||
|
||||
**ВАЖНО:** Если вы хотите использовать RoCEv2 (как мы и рекомендуем), то
|
||||
правильный rdma_gid_index, как правило, 1 (IPv6) или 3 (IPv4).
|
||||
|
||||
## rdma_mtu
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4096
|
||||
|
||||
Максимальная единица передачи (Path MTU) для RDMA. Должно быть равно 1024,
|
||||
2048 или 4096. Обычно нет смысла менять значение по умолчанию, равное 4096.
|
||||
|
||||
## rdma_max_sge
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 128
|
||||
|
||||
Максимальное число записей разделения/сборки (scatter/gather) для RDMA.
|
||||
OSD в любом случае согласовывают реальное значение при установке соединения,
|
||||
так что менять этот параметр обычно не нужно.
|
||||
|
||||
## rdma_max_msg
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 1048576
|
||||
|
||||
Максимальный размер одной RDMA-операции отправки или приёма.
|
||||
|
||||
## rdma_max_recv
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 8
|
||||
|
||||
Максимальное число параллельных RDMA-операций получения данных. Следует
|
||||
иметь в виду, что данное число буферов размером `rdma_max_msg` выделяется
|
||||
для каждого подключённого клиентского соединения, так что данная настройка
|
||||
влияет на потребление памяти. Это так потому, что RDMA-приём данных в
|
||||
Vitastor, увы, всё равно не является zero-copy, т.е. всё равно 1 раз
|
||||
копирует данные в памяти. Данная особенность, возможно, будет исправлена в
|
||||
более новых версиях Vitastor.
|
||||
|
||||
## peer_connect_interval
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
- Минимальное значение: 1
|
||||
|
||||
Время ожидания перед повторной попыткой соединиться с недоступным OSD.
|
||||
|
||||
## peer_connect_timeout
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
- Минимальное значение: 1
|
||||
|
||||
Максимальное время ожидания попытки соединения с OSD.
|
||||
|
||||
## osd_idle_timeout
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
- Минимальное значение: 1
|
||||
|
||||
Время неактивности соединения с OSD, после которого клиенты или другие OSD
|
||||
посылают запрос проверки состояния соединения.
|
||||
|
||||
## osd_ping_timeout
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
- Минимальное значение: 1
|
||||
|
||||
Максимальное время ожидания ответа на запрос проверки состояния соединения.
|
||||
Если OSD не отвечает за это время, соединение отключается и производится
|
||||
повторная попытка соединения.
|
||||
|
||||
## up_wait_retry_interval
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 500
|
||||
- Минимальное значение: 50
|
||||
|
||||
Когда OSD получают от клиентов запросы ввода-вывода, относящиеся к не
|
||||
поднятым на данный момент на них PG, либо к PG в процессе синхронизации,
|
||||
они отвечают клиентам специальным кодом ошибки, означающим, что клиент
|
||||
должен некоторое время подождать перед повторением запроса. Именно это время
|
||||
ожидания задаёт данный параметр.
|
||||
|
||||
## max_etcd_attempts
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 5
|
||||
|
||||
Максимальное число попыток выполнения запросов к etcd для тех запросов,
|
||||
которые нельзя повторять бесконечно.
|
||||
|
||||
## etcd_quick_timeout
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 1000
|
||||
|
||||
Максимальное время выполнения запросов к etcd, которые должны завершаться
|
||||
быстро, таких, как обновление резервации (lease).
|
||||
|
||||
## etcd_slow_timeout
|
||||
|
||||
- Тип: миллисекунды
|
||||
- Значение по умолчанию: 5000
|
||||
|
||||
Максимальное время выполнения запросов к etcd, для которых не обязательно
|
||||
гарантировать быстрое выполнение.
|
||||
|
||||
## etcd_keepalive_timeout
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: max(30, etcd_report_interval*2)
|
||||
|
||||
Таймаут для HTTP Keep-Alive в соединениях к etcd. Должен быть больше, чем
|
||||
etcd_report_interval, чтобы keepalive гарантированно работал.
|
||||
|
||||
## etcd_ws_keepalive_timeout
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 30
|
||||
|
||||
Интервал проверки живости вебсокет-подключений к etcd.
|
|
@ -1,297 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Runtime OSD Parameters
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](osd.ru.md)
|
||||
|
||||
# Runtime OSD Parameters
|
||||
|
||||
These parameters only apply to OSDs, are not fixed at the moment of OSD drive
|
||||
initialization and can be changed with an OSD restart.
|
||||
|
||||
- [etcd_report_interval](#etcd_report_interval)
|
||||
- [run_primary](#run_primary)
|
||||
- [osd_network](#osd_network)
|
||||
- [bind_address](#bind_address)
|
||||
- [bind_port](#bind_port)
|
||||
- [autosync_interval](#autosync_interval)
|
||||
- [autosync_writes](#autosync_writes)
|
||||
- [recovery_queue_depth](#recovery_queue_depth)
|
||||
- [recovery_sync_batch](#recovery_sync_batch)
|
||||
- [readonly](#readonly)
|
||||
- [no_recovery](#no_recovery)
|
||||
- [no_rebalance](#no_rebalance)
|
||||
- [print_stats_interval](#print_stats_interval)
|
||||
- [slow_log_interval](#slow_log_interval)
|
||||
- [max_write_iodepth](#max_write_iodepth)
|
||||
- [min_flusher_count](#min_flusher_count)
|
||||
- [max_flusher_count](#max_flusher_count)
|
||||
- [inmemory_metadata](#inmemory_metadata)
|
||||
- [inmemory_journal](#inmemory_journal)
|
||||
- [journal_sector_buffer_count](#journal_sector_buffer_count)
|
||||
- [journal_no_same_sector_overwrites](#journal_no_same_sector_overwrites)
|
||||
- [throttle_small_writes](#throttle_small_writes)
|
||||
- [throttle_target_iops](#throttle_target_iops)
|
||||
- [throttle_target_mbs](#throttle_target_mbs)
|
||||
- [throttle_target_parallelism](#throttle_target_parallelism)
|
||||
- [throttle_threshold_us](#throttle_threshold_us)
|
||||
- [osd_memlock](#osd_memlock)
|
||||
|
||||
## etcd_report_interval
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
|
||||
Interval at which OSDs report their state to etcd. Affects OSD lease time
|
||||
and thus the failover speed. Lease time is equal to this parameter value
|
||||
plus max_etcd_attempts * etcd_quick_timeout because it should be guaranteed
|
||||
that every OSD always refreshes its lease in time.
|
||||
|
||||
## run_primary
|
||||
|
||||
- Type: boolean
|
||||
- Default: true
|
||||
|
||||
Start primary OSD logic on this OSD. As of now, can be turned off only for
|
||||
debugging purposes. It's possible to implement additional feature for the
|
||||
monitor which may allow to separate primary and secondary OSDs, but it's
|
||||
unclear why anyone could need it, so it's not implemented.
|
||||
|
||||
## osd_network
|
||||
|
||||
- Type: string or array of strings
|
||||
|
||||
Network mask of the network (IPv4 or IPv6) to use for OSDs. Note that
|
||||
although it's possible to specify multiple networks here, this does not
|
||||
mean that OSDs will create multiple listening sockets - they'll only
|
||||
pick the first matching address of an UP + RUNNING interface. Separate
|
||||
networks for cluster and client connections are also not implemented, but
|
||||
they are mostly useless anyway, so it's not a big deal.
|
||||
|
||||
## bind_address
|
||||
|
||||
- Type: string
|
||||
- Default: 0.0.0.0
|
||||
|
||||
Instead of the network mask, you can also set OSD listen address explicitly
|
||||
using this parameter. May be useful if you want to start OSDs on interfaces
|
||||
that are not UP + RUNNING.
|
||||
|
||||
## bind_port
|
||||
|
||||
- Type: integer
|
||||
|
||||
By default, OSDs pick random ports to use for incoming connections
|
||||
automatically. With this option you can set a specific port for a specific
|
||||
OSD by hand.
|
||||
|
||||
## autosync_interval
|
||||
|
||||
- Type: seconds
|
||||
- Default: 5
|
||||
|
||||
Time interval at which automatic fsyncs/flushes are issued by each OSD when
|
||||
the immediate_commit mode if disabled. fsyncs are required because without
|
||||
them OSDs quickly fill their journals, become unable to clear them and
|
||||
stall. Also this option limits the amount of recent uncommitted changes
|
||||
which OSDs may lose in case of a power outage in case when clients don't
|
||||
issue fsyncs at all.
|
||||
|
||||
## autosync_writes
|
||||
|
||||
- Type: integer
|
||||
- Default: 128
|
||||
|
||||
Same as autosync_interval, but sets the maximum number of uncommitted write
|
||||
operations before issuing an fsync operation internally.
|
||||
|
||||
## recovery_queue_depth
|
||||
|
||||
- Type: integer
|
||||
- Default: 4
|
||||
|
||||
Maximum recovery operations per one primary OSD at any given moment of time.
|
||||
Currently it's the only parameter available to tune the speed or recovery
|
||||
and rebalancing, but it's planned to implement more.
|
||||
|
||||
## recovery_sync_batch
|
||||
|
||||
- Type: integer
|
||||
- Default: 16
|
||||
|
||||
Maximum number of recovery operations before issuing an additional fsync.
|
||||
|
||||
## readonly
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Read-only mode. If this is enabled, an OSD will never issue any writes to
|
||||
the underlying device. This may be useful for recovery purposes.
|
||||
|
||||
## no_recovery
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Disable automatic background recovery of objects. Note that it doesn't
|
||||
affect implicit recovery of objects happening during writes - a write is
|
||||
always made to a full set of at least pg_minsize OSDs.
|
||||
|
||||
## no_rebalance
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Disable background movement of data between different OSDs. Disabling it
|
||||
means that PGs in the `has_misplaced` state will be left in it indefinitely.
|
||||
|
||||
## print_stats_interval
|
||||
|
||||
- Type: seconds
|
||||
- Default: 3
|
||||
|
||||
Time interval at which OSDs print simple human-readable operation
|
||||
statistics on stdout.
|
||||
|
||||
## slow_log_interval
|
||||
|
||||
- Type: seconds
|
||||
- Default: 10
|
||||
|
||||
Time interval at which OSDs dump slow or stuck operations on stdout, if
|
||||
they're any. Also it's the time after which an operation is considered
|
||||
"slow".
|
||||
|
||||
## max_write_iodepth
|
||||
|
||||
- Type: integer
|
||||
- Default: 128
|
||||
|
||||
Parallel client write operation limit per one OSD. Operations that exceed
|
||||
this limit are pushed to a temporary queue instead of being executed
|
||||
immediately.
|
||||
|
||||
## min_flusher_count
|
||||
|
||||
- Type: integer
|
||||
- Default: 1
|
||||
|
||||
Flusher is a micro-thread that moves data from the journal to the data
|
||||
area of the device. Their number is auto-tuned between minimum and maximum.
|
||||
Minimum number is set by this parameter.
|
||||
|
||||
## max_flusher_count
|
||||
|
||||
- Type: integer
|
||||
- Default: 256
|
||||
|
||||
Maximum number of journal flushers (see above min_flusher_count).
|
||||
|
||||
## inmemory_metadata
|
||||
|
||||
- Type: boolean
|
||||
- Default: true
|
||||
|
||||
This parameter makes Vitastor always keep metadata area of the block device
|
||||
in memory. It's required for good performance because it allows to avoid
|
||||
additional read-modify-write cycles during metadata modifications. Metadata
|
||||
area size is currently roughly 224 MB per 1 TB of data. You can turn it off
|
||||
to reduce memory usage by this value, but it will hurt performance. This
|
||||
restriction is likely to be removed in the future along with the upgrade
|
||||
of the metadata storage scheme.
|
||||
|
||||
## inmemory_journal
|
||||
|
||||
- Type: boolean
|
||||
- Default: true
|
||||
|
||||
This parameter make Vitastor always keep journal area of the block
|
||||
device in memory. Turning it off will, again, reduce memory usage, but
|
||||
hurt performance because flusher coroutines will have to read data from
|
||||
the disk back before copying it into the main area. The memory usage benefit
|
||||
is typically very small because it's sufficient to have 16-32 MB journal
|
||||
for SSD OSDs. However, in theory it's possible that you'll want to turn it
|
||||
off for hybrid (HDD+SSD) OSDs with large journals on quick devices.
|
||||
|
||||
## journal_sector_buffer_count
|
||||
|
||||
- Type: integer
|
||||
- Default: 32
|
||||
|
||||
Maximum number of buffers that can be used for writing journal metadata
|
||||
blocks. The only situation when you should increase it to a larger value
|
||||
is when you enable journal_no_same_sector_overwrites. In this case set
|
||||
it to, for example, 1024.
|
||||
|
||||
## journal_no_same_sector_overwrites
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Enable this option for SSDs like Intel D3-S4510 and D3-S4610 which REALLY
|
||||
don't like when a program overwrites the same sector multiple times in a
|
||||
row and slow down significantly (from 25000+ iops to ~3000 iops). When
|
||||
this option is set, Vitastor will always move to the next sector of the
|
||||
journal after writing it instead of possibly overwriting it the second time.
|
||||
|
||||
Most (99%) other SSDs don't need this option.
|
||||
|
||||
## throttle_small_writes
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Enable soft throttling of small journaled writes. Useful for hybrid OSDs
|
||||
with fast journal/metadata devices and slow data devices. The idea is that
|
||||
small writes complete very quickly because they're first written to the
|
||||
journal device, but moving them to the main device is slow. So if an OSD
|
||||
allows clients to issue a lot of small writes it will perform very good
|
||||
for several seconds and then the journal will fill up and the performance
|
||||
will drop to almost zero. Throttling is meant to prevent this problem by
|
||||
artifically slowing quick writes down based on the amount of free space in
|
||||
the journal. When throttling is used, the performance of small writes will
|
||||
decrease smoothly instead of abrupt drop at the moment when the journal
|
||||
fills up.
|
||||
|
||||
## throttle_target_iops
|
||||
|
||||
- Type: integer
|
||||
- Default: 100
|
||||
|
||||
Target maximum number of throttled operations per second under the condition
|
||||
of full journal. Set it to approximate random write iops of your data devices
|
||||
(HDDs).
|
||||
|
||||
## throttle_target_mbs
|
||||
|
||||
- Type: integer
|
||||
- Default: 100
|
||||
|
||||
Target maximum bandwidth in MB/s of throttled operations per second under
|
||||
the condition of full journal. Set it to approximate linear write
|
||||
performance of your data devices (HDDs).
|
||||
|
||||
## throttle_target_parallelism
|
||||
|
||||
- Type: integer
|
||||
- Default: 1
|
||||
|
||||
Target maximum parallelism of throttled operations under the condition of
|
||||
full journal. Set it to approximate internal parallelism of your data
|
||||
devices (1 for HDDs, 4-8 for SSDs).
|
||||
|
||||
## throttle_threshold_us
|
||||
|
||||
- Type: microseconds
|
||||
- Default: 50
|
||||
|
||||
Minimal computed delay to be applied to throttled operations. Usually
|
||||
doesn't need to be changed.
|
||||
|
||||
## osd_memlock
|
||||
|
||||
- Type: boolean
|
||||
- Default: false
|
||||
|
||||
Lock all OSD memory to prevent it from being unloaded into swap with mlockall(). Requires sufficient ulimit -l (max locked memory).
|
|
@ -1,310 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Изменяемые параметры OSD
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](osd.en.md)
|
||||
|
||||
# Изменяемые параметры OSD
|
||||
|
||||
Данные параметры используются только OSD, но, в отличие от дисковых параметров,
|
||||
не фиксируются в момент инициализации дисков OSD и могут быть изменены в любой
|
||||
момент с перезапуском OSD.
|
||||
|
||||
- [etcd_report_interval](#etcd_report_interval)
|
||||
- [run_primary](#run_primary)
|
||||
- [osd_network](#osd_network)
|
||||
- [bind_address](#bind_address)
|
||||
- [bind_port](#bind_port)
|
||||
- [autosync_interval](#autosync_interval)
|
||||
- [autosync_writes](#autosync_writes)
|
||||
- [recovery_queue_depth](#recovery_queue_depth)
|
||||
- [recovery_sync_batch](#recovery_sync_batch)
|
||||
- [readonly](#readonly)
|
||||
- [no_recovery](#no_recovery)
|
||||
- [no_rebalance](#no_rebalance)
|
||||
- [print_stats_interval](#print_stats_interval)
|
||||
- [slow_log_interval](#slow_log_interval)
|
||||
- [max_write_iodepth](#max_write_iodepth)
|
||||
- [min_flusher_count](#min_flusher_count)
|
||||
- [max_flusher_count](#max_flusher_count)
|
||||
- [inmemory_metadata](#inmemory_metadata)
|
||||
- [inmemory_journal](#inmemory_journal)
|
||||
- [journal_sector_buffer_count](#journal_sector_buffer_count)
|
||||
- [journal_no_same_sector_overwrites](#journal_no_same_sector_overwrites)
|
||||
- [throttle_small_writes](#throttle_small_writes)
|
||||
- [throttle_target_iops](#throttle_target_iops)
|
||||
- [throttle_target_mbs](#throttle_target_mbs)
|
||||
- [throttle_target_parallelism](#throttle_target_parallelism)
|
||||
- [throttle_threshold_us](#throttle_threshold_us)
|
||||
- [osd_memlock](#osd_memlock)
|
||||
|
||||
## etcd_report_interval
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
|
||||
Интервал, с которым OSD обновляет своё состояние в etcd. Значение параметра
|
||||
влияет на время резервации (lease) OSD и поэтому на скорость переключения
|
||||
при падении OSD. Время lease равняется значению этого параметра плюс
|
||||
max_etcd_attempts * etcd_quick_timeout.
|
||||
|
||||
## run_primary
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: true
|
||||
|
||||
Запускать логику первичного OSD на данном OSD. На данный момент отключать
|
||||
эту опцию может иметь смысл только в целях отладки. В теории, можно
|
||||
реализовать дополнительный режим для монитора, который позволит отделять
|
||||
первичные OSD от вторичных, но пока не понятно, зачем это может кому-то
|
||||
понадобиться, поэтому это не реализовано.
|
||||
|
||||
## osd_network
|
||||
|
||||
- Тип: строка или массив строк
|
||||
|
||||
Маска подсети (IPv4 или IPv6) для использования для соединений с OSD.
|
||||
Имейте в виду, что хотя сейчас и можно передать в этот параметр несколько
|
||||
подсетей, это не означает, что OSD будут создавать несколько слушающих
|
||||
сокетов - они лишь будут выбирать адрес первого поднятого (состояние UP +
|
||||
RUNNING), подходящий под заданную маску. Также не реализовано разделение
|
||||
кластерной и публичной сетей OSD. Правда, от него обычно всё равно довольно
|
||||
мало толку, так что особенной проблемы в этом нет.
|
||||
|
||||
## bind_address
|
||||
|
||||
- Тип: строка
|
||||
- Значение по умолчанию: 0.0.0.0
|
||||
|
||||
Этим параметром можно явным образом задать адрес, на котором будет ожидать
|
||||
соединений OSD (вместо использования маски подсети). Может быть полезно,
|
||||
например, чтобы запускать OSD на неподнятых интерфейсах (не UP + RUNNING).
|
||||
|
||||
## bind_port
|
||||
|
||||
- Тип: целое число
|
||||
|
||||
По умолчанию OSD сами выбирают случайные порты для входящих подключений.
|
||||
С помощью данной опции вы можете задать порт для отдельного OSD вручную.
|
||||
|
||||
## autosync_interval
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 5
|
||||
|
||||
Временной интервал отправки автоматических fsync-ов (операций очистки кэша)
|
||||
каждым OSD для случая, когда режим immediate_commit отключён. fsync-и нужны
|
||||
OSD, чтобы успевать очищать журнал - без них OSD быстро заполняют журналы и
|
||||
перестают обрабатывать операции записи. Также эта опция ограничивает объём
|
||||
недавних незафиксированных изменений, которые OSD могут терять при
|
||||
отключении питания, если клиенты вообще не отправляют fsync.
|
||||
|
||||
## autosync_writes
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 128
|
||||
|
||||
Аналогично autosync_interval, но задаёт не временной интервал, а
|
||||
максимальное количество незафиксированных операций записи перед
|
||||
принудительной отправкой fsync-а.
|
||||
|
||||
## recovery_queue_depth
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 4
|
||||
|
||||
Максимальное число операций восстановления на одном первичном OSD в любой
|
||||
момент времени. На данный момент единственный параметр, который можно менять
|
||||
для ускорения или замедления восстановления и перебалансировки данных, но
|
||||
в планах реализация других параметров.
|
||||
|
||||
## recovery_sync_batch
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 16
|
||||
|
||||
Максимальное число операций восстановления перед дополнительным fsync.
|
||||
|
||||
## readonly
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Режим "только чтение". Если включить этот режим, OSD не будет писать ничего
|
||||
на диск. Может быть полезно в целях восстановления.
|
||||
|
||||
## no_recovery
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Отключить автоматическое фоновое восстановление объектов. Обратите внимание,
|
||||
что эта опция не отключает восстановление объектов, происходящее при
|
||||
записи - запись всегда производится в полный набор из как минимум pg_minsize
|
||||
OSD.
|
||||
|
||||
## no_rebalance
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Отключить фоновое перемещение объектов между разными OSD. Отключение
|
||||
означает, что PG, находящиеся в состоянии `has_misplaced`, будут оставлены
|
||||
в нём на неопределённый срок.
|
||||
|
||||
## print_stats_interval
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 3
|
||||
|
||||
Временной интервал, с которым OSD печатают простую человекочитаемую
|
||||
статистику выполнения операций в стандартный вывод.
|
||||
|
||||
## slow_log_interval
|
||||
|
||||
- Тип: секунды
|
||||
- Значение по умолчанию: 10
|
||||
|
||||
Временной интервал, с которым OSD выводят в стандартный вывод список
|
||||
медленных или зависших операций, если таковые имеются. Также время, при
|
||||
превышении которого операция считается "медленной".
|
||||
|
||||
## max_write_iodepth
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 128
|
||||
|
||||
Максимальное число одновременных клиентских операций записи на один OSD.
|
||||
Операции, превышающие этот лимит, не исполняются сразу, а сохраняются во
|
||||
временной очереди.
|
||||
|
||||
## min_flusher_count
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 1
|
||||
|
||||
Flusher - это микро-поток (корутина), которая копирует данные из журнала в
|
||||
основную область устройства данных. Их число настраивается динамически между
|
||||
минимальным и максимальным значением. Этот параметр задаёт минимальное число.
|
||||
|
||||
## max_flusher_count
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 256
|
||||
|
||||
Максимальное число микро-потоков очистки журнала (см. выше min_flusher_count).
|
||||
|
||||
## inmemory_metadata
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: true
|
||||
|
||||
Данный параметр заставляет Vitastor всегда держать область метаданных диска
|
||||
в памяти. Это нужно, чтобы избегать дополнительных операций чтения с диска
|
||||
при записи. Размер области метаданных на данный момент составляет примерно
|
||||
224 МБ на 1 ТБ данных. При включении потребление памяти снизится примерно
|
||||
на эту величину, но при этом также снизится и производительность. В будущем,
|
||||
после обновления схемы хранения метаданных, это ограничение, скорее всего,
|
||||
будет ликвидировано.
|
||||
|
||||
## inmemory_journal
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: true
|
||||
|
||||
Данный параметр заставляет Vitastor всегда держать в памяти журналы OSD.
|
||||
Отключение параметра, опять же, снижает потребление памяти, но ухудшает
|
||||
производительность, так как для копирования данных из журнала в основную
|
||||
область устройства OSD будут вынуждены читать их обратно с диска. Выигрыш
|
||||
по памяти при этом обычно крайне низкий, так как для SSD OSD обычно
|
||||
достаточно 16- или 32-мегабайтного журнала. Однако в теории отключение
|
||||
параметра может оказаться полезным для гибридных OSD (HDD+SSD) с большими
|
||||
журналами, расположенными на быстром по сравнению с HDD устройстве.
|
||||
|
||||
## journal_sector_buffer_count
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 32
|
||||
|
||||
Максимальное число буферов, разрешённых для использования под записываемые
|
||||
в журнал блоки метаданных. Единственная ситуация, в которой этот параметр
|
||||
нужно менять - это если вы включаете journal_no_same_sector_overwrites. В
|
||||
этом случае установите данный параметр, например, в 1024.
|
||||
|
||||
## journal_no_same_sector_overwrites
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Включайте данную опцию для SSD вроде Intel D3-S4510 и D3-S4610, которые
|
||||
ОЧЕНЬ не любят, когда ПО перезаписывает один и тот же сектор несколько раз
|
||||
подряд. Такие SSD при многократной перезаписи одного и того же сектора
|
||||
сильно замедляются - условно, с 25000 и более iops до 3000 iops. Когда
|
||||
данная опция установлена, Vitastor всегда переходит к следующему сектору
|
||||
журнала после записи вместо потенциально повторной перезаписи того же
|
||||
самого сектора.
|
||||
|
||||
Почти все другие SSD (99% моделей) не требуют данной опции.
|
||||
|
||||
## throttle_small_writes
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Разрешить мягкое ограничение скорости журналируемой записи. Полезно для
|
||||
гибридных OSD с быстрыми устройствами метаданных и медленными устройствами
|
||||
данных. Идея заключается в том, что мелкие записи в этой ситуации могут
|
||||
завершаться очень быстро, так как они изначально записываются на быстрое
|
||||
журнальное устройство (SSD). Но перемещать их потом на основное медленное
|
||||
устройство долго. Поэтому если OSD быстро примет от клиентов очень много
|
||||
мелких операций записи, он быстро заполнит свой журнал, после чего
|
||||
производительность записи резко упадёт практически до нуля. Ограничение
|
||||
скорости записи призвано решить эту проблему с помощью искусственного
|
||||
замедления операций записи на основании объёма свободного места в журнале.
|
||||
Когда эта опция включена, производительность мелких операций записи будет
|
||||
снижаться плавно, а не резко в момент окончательного заполнения журнала.
|
||||
|
||||
## throttle_target_iops
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 100
|
||||
|
||||
Расчётное максимальное число ограничиваемых операций в секунду при условии
|
||||
отсутствия свободного места в журнале. Устанавливайте приблизительно равным
|
||||
максимальной производительности случайной записи ваших устройств данных
|
||||
(HDD) в операциях в секунду.
|
||||
|
||||
## throttle_target_mbs
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 100
|
||||
|
||||
Расчётный максимальный размер в МБ/с ограничиваемых операций в секунду при
|
||||
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
|
||||
равным максимальной производительности линейной записи ваших устройств
|
||||
данных (HDD).
|
||||
|
||||
## throttle_target_parallelism
|
||||
|
||||
- Тип: целое число
|
||||
- Значение по умолчанию: 1
|
||||
|
||||
Расчётный максимальный параллелизм ограничиваемых операций в секунду при
|
||||
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
|
||||
равным внутреннему параллелизму ваших устройств данных (1 для HDD, 4-8
|
||||
для SSD).
|
||||
|
||||
## throttle_threshold_us
|
||||
|
||||
- Тип: микросекунды
|
||||
- Значение по умолчанию: 50
|
||||
|
||||
Минимальная применимая к ограничиваемым операциям задержка. Обычно не
|
||||
требует изменений.
|
||||
|
||||
## osd_memlock
|
||||
|
||||
- Тип: булево (да/нет)
|
||||
- Значение по умолчанию: false
|
||||
|
||||
Блокировать всю память OSD с помощью mlockall, чтобы запретить её выгрузку в пространство подкачки. Требует достаточного значения ulimit -l (лимита заблокированной памяти).
|
|
@ -1,254 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Pool configuration
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](pool.ru.md)
|
||||
|
||||
# Pool configuration
|
||||
|
||||
Pool configuration is set in etcd key `/vitastor/config/pools` in the following
|
||||
JSON format:
|
||||
|
||||
```
|
||||
{
|
||||
"<Numeric ID>": {
|
||||
"name": "<name>",
|
||||
...other parameters...
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Pool configuration is also affected by:
|
||||
|
||||
- [OSD Placement Tree](#placement-tree)
|
||||
- [Separate OSD settings](#osd-settings)
|
||||
|
||||
Parameters:
|
||||
|
||||
- [name](#name)
|
||||
- [scheme](#scheme)
|
||||
- [pg_size](#pg_size)
|
||||
- [parity_chunks](#parity_chunks)
|
||||
- [pg_minsize](#pg_minsize)
|
||||
- [pg_count](#pg_count)
|
||||
- [failure_domain](#failure_domain)
|
||||
- [max_osd_combinations](#max_osd_combinations)
|
||||
- [pg_stripe_size](#pg_stripe_size)
|
||||
- [root_node](#root_node)
|
||||
- [osd_tags](#osd_tags)
|
||||
- [primary_affinity_tags](#primary_affinity_tags)
|
||||
|
||||
Examples:
|
||||
|
||||
- [Replicated Pool](#replicated-pool)
|
||||
- [Erasure-coded Pool](#erasure-coded-pool)
|
||||
|
||||
# Placement Tree
|
||||
|
||||
OSD placement tree is set in a separate etcd key `/vitastor/config/node_placement`
|
||||
in the following JSON format:
|
||||
|
||||
`
|
||||
{
|
||||
"<node name or OSD number>": {
|
||||
"level": "<level>",
|
||||
"parent": "<parent node name, if any>"
|
||||
},
|
||||
...
|
||||
}
|
||||
`
|
||||
|
||||
Here, if a node name is a number then it is assumed to refer to an OSD.
|
||||
Level of the OSD is always "osd" and cannot be overriden. You may only
|
||||
override parent node of the OSD which is its host by default.
|
||||
|
||||
Non-numeric node names refer to other placement tree nodes like hosts, racks,
|
||||
datacenters and so on.
|
||||
|
||||
Hosts of all OSDs are auto-created in the tree with level "host" and name
|
||||
equal to the host name reported by a corresponding OSD. You can refer to them
|
||||
without adding them to this JSON tree manually.
|
||||
|
||||
Level may be "host", "osd" or refer to some other placement tree level
|
||||
from [placement_levels](monitor.en.md#placement_levels).
|
||||
|
||||
Parent node reference is required for intermediate tree nodes.
|
||||
|
||||
# OSD settings
|
||||
|
||||
Separate OSD settings are set in etc keys `/vitastor/config/osd/<number>`
|
||||
in JSON format `{"<key>":<value>}`.
|
||||
|
||||
As of now, there is only one setting:
|
||||
|
||||
## reweight
|
||||
|
||||
- Type: number, between 0 and 1
|
||||
- Default: 1
|
||||
|
||||
Every OSD receives PGs proportional to its size. Reweight is a multiplier for
|
||||
OSD size used during PG distribution.
|
||||
|
||||
This means an OSD configured with reweight lower than 1 receives less PGs than
|
||||
it normally would. An OSD with reweight = 0 won't store any data. You can set
|
||||
reweight to 0 to trigger rebalance and remove all data from an OSD.
|
||||
|
||||
# Pool parameters
|
||||
|
||||
## name
|
||||
|
||||
- Type: string
|
||||
- Required
|
||||
|
||||
Pool name.
|
||||
|
||||
## scheme
|
||||
|
||||
- Type: string
|
||||
- Required
|
||||
- One of: "replicated", "xor" or "jerasure"
|
||||
|
||||
Redundancy scheme used for data in this pool.
|
||||
|
||||
## pg_size
|
||||
|
||||
- Type: integer
|
||||
- Required
|
||||
|
||||
Total number of disks for PGs of this pool - i.e., number of replicas for
|
||||
replicated pools and number of data plus parity disks for EC/XOR pools.
|
||||
|
||||
## parity_chunks
|
||||
|
||||
- Type: integer
|
||||
|
||||
Number of parity chunks for EC/XOR pools. For such pools, data will be lost
|
||||
if you lose more than parity_chunks disks at once, so this parameter can be
|
||||
equally described as FTT (number of failures to tolerate).
|
||||
|
||||
Required for EC/XOR pools, ignored for replicated pools.
|
||||
|
||||
## pg_minsize
|
||||
|
||||
- Type: integer
|
||||
- Required
|
||||
|
||||
Number of available live disks for PGs of this pool to remain active.
|
||||
That is, if it becomes impossible to place PG data on at least (pg_minsize)
|
||||
OSDs, PG is deactivated for both read and write. So you know that a fresh
|
||||
write always goes to at least (pg_minsize) OSDs (disks).
|
||||
|
||||
FIXME: pg_minsize behaviour may be changed in the future to only make PGs
|
||||
read-only instead of deactivating them.
|
||||
|
||||
## pg_count
|
||||
|
||||
- Type: integer
|
||||
- Required
|
||||
|
||||
Number of PGs for this pool. The value should be big enough for the monitor /
|
||||
LP solver to be able to optimize data placement.
|
||||
|
||||
"Enough" is usually around 64-128 PGs per OSD, i.e. you set pg_count for pool
|
||||
to (total OSD count * 100 / pg_size). You can round it to the closest power of 2,
|
||||
because it makes it easier to reduce or increase PG count later by dividing or
|
||||
multiplying it by 2.
|
||||
|
||||
In Vitastor, PGs are ephemeral, so you can change pool PG count anytime just
|
||||
by overwriting pool configuration in etcd. Amount of the data affected by
|
||||
rebalance will be smaller if the new PG count is a multiple of the old PG count
|
||||
or vice versa.
|
||||
|
||||
## failure_domain
|
||||
|
||||
- Type: string
|
||||
- Default: host
|
||||
|
||||
Failure domain specification. Must be "host" or "osd" or refer to one of the
|
||||
placement tree levels, defined in [placement_levels](monitor.en.md#placement_levels).
|
||||
|
||||
Two replicas, or two parts in case of EC/XOR, of the same block of data are
|
||||
never put on OSDs in the same failure domain (for example, on the same host).
|
||||
So failure domain specifies the unit which failure you are protecting yourself
|
||||
from.
|
||||
|
||||
## max_osd_combinations
|
||||
|
||||
- Type: integer
|
||||
- Default: 10000
|
||||
|
||||
Vitastor data placement algorithm is based on the LP solver and OSD combinations
|
||||
which are fed to it are generated ramdonly. This parameter specifies the maximum
|
||||
number of combinations to generate when optimising PG placement.
|
||||
|
||||
This parameter usually doesn't require to be changed.
|
||||
|
||||
## pg_stripe_size
|
||||
|
||||
- Type: integer
|
||||
- Default: 0
|
||||
|
||||
Specifies the stripe size for this pool according to which images are split into
|
||||
different PGs. Stripe size can't be smaller than [block_size](layout-cluster.en.md#block_size)
|
||||
multiplied by (pg_size - parity_chunks) for EC/XOR pools, or 1 for replicated pools,
|
||||
and the same value is used by default.
|
||||
|
||||
This means first `pg_stripe_size = (block_size * (pg_size-parity_chunks))` bytes
|
||||
of an image go to one PG, next `pg_stripe_size` bytes go to another PG and so on.
|
||||
|
||||
Usually doesn't require to be changed separately from the block size.
|
||||
|
||||
## root_node
|
||||
|
||||
- Type: string
|
||||
|
||||
Specifies the root node of the OSD tree to restrict this pool OSDs to.
|
||||
Referenced root node must exist in /vitastor/config/node_placement.
|
||||
|
||||
## osd_tags
|
||||
|
||||
- Type: string or array of strings
|
||||
|
||||
Specifies OSD tags to restrict this pool to. If multiple tags are specified,
|
||||
only OSDs having all of these tags will be used for this pool.
|
||||
|
||||
## primary_affinity_tags
|
||||
|
||||
- Type: string or array of strings
|
||||
|
||||
Specifies OSD tags to prefer putting primary OSDs in this pool to.
|
||||
Note that for EC/XOR pools Vitastor always prefers to put primary OSD on one
|
||||
of the OSDs containing a data chunk for a PG.
|
||||
|
||||
# Examples
|
||||
|
||||
## Replicated pool
|
||||
|
||||
```
|
||||
{
|
||||
"1": {
|
||||
"name":"testpool",
|
||||
"scheme":"replicated",
|
||||
"pg_size":2,
|
||||
"pg_minsize":1,
|
||||
"pg_count":256,
|
||||
"failure_domain":"host"
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
## Erasure-coded pool
|
||||
|
||||
```
|
||||
{
|
||||
"2": {
|
||||
"name":"ecpool",
|
||||
"scheme":"jerasure",
|
||||
"pg_size":3,
|
||||
"parity_chunks":1,
|
||||
"pg_minsize":2,
|
||||
"pg_count":256,
|
||||
"failure_domain":"host"
|
||||
}
|
||||
}
|
||||
```
|
|
@ -1,253 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Конфигурация пулов
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](pool.en.md)
|
||||
|
||||
# Конфигурация пулов
|
||||
|
||||
Настройки пулов задаются в ключе etcd `/vitastor/config/pools` в JSON-формате:
|
||||
|
||||
```
|
||||
{
|
||||
"<Численный ID>": {
|
||||
"name": "<имя>",
|
||||
...остальные параметры...
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
На настройку пулов также влияют:
|
||||
|
||||
- [Дерево размещения OSD](#дерево-размещения)
|
||||
- [Настройки отдельных OSD](#настройки-osd)
|
||||
|
||||
Параметры:
|
||||
|
||||
- [name](#name)
|
||||
- [scheme](#scheme)
|
||||
- [pg_size](#pg_size)
|
||||
- [parity_chunks](#parity_chunks)
|
||||
- [pg_minsize](#pg_minsize)
|
||||
- [pg_count](#pg_count)
|
||||
- [failure_domain](#failure_domain)
|
||||
- [max_osd_combinations](#max_osd_combinations)
|
||||
- [pg_stripe_size](#pg_stripe_size)
|
||||
- [root_node](#root_node)
|
||||
- [osd_tags](#osd_tags)
|
||||
- [primary_affinity_tags](#primary_affinity_tags)
|
||||
|
||||
Примеры:
|
||||
|
||||
- [Реплицированный пул](#реплицированный-пул)
|
||||
- [Пул с кодами коррекции ошибок 2+1](#пул-с-кодами-коррекции-ошибок)
|
||||
|
||||
# Дерево размещения
|
||||
|
||||
Дерево размещения OSD задаётся в отдельном ключе etcd `/vitastor/config/node_placement`
|
||||
в следующем JSON-формате:
|
||||
|
||||
`
|
||||
{
|
||||
"<имя узла или номер OSD>": {
|
||||
"level": "<уровень>",
|
||||
"parent": "<имя родительского узла, если есть>"
|
||||
},
|
||||
...
|
||||
}
|
||||
`
|
||||
|
||||
Здесь, если название узла - число, считается, что это OSD. Уровень OSD
|
||||
всегда равен "osd" и не может быть переопределён. Для OSD вы можете только
|
||||
переопределить родительский узел. По умолчанию родителем OSD считается его хост.
|
||||
|
||||
Нечисловые имена узлов относятся к другим узлам дерева OSD, таким, как хосты (серверы),
|
||||
стойки, датацентры и так далее.
|
||||
|
||||
Хосты всех OSD автоматически создаются в дереве с уровнем "host" и именем, равным имени хоста,
|
||||
сообщаемым соответствующим OSD. Вы можете ссылаться на эти хосты, не заводя их
|
||||
в дереве вручную.
|
||||
|
||||
Уровень может быть "host", "osd" или относиться к другому уровню размещения из
|
||||
[placement_levels](monitor.ru.md#placement_levels).
|
||||
|
||||
Родительский узел нужен только для промежуточных узлов дерева.
|
||||
|
||||
# Настройки OSD
|
||||
|
||||
Настройки отдельных OSD задаются в ключах etcd `/vitastor/config/osd/<number>`
|
||||
в JSON-формате `{"<key>":<value>}`.
|
||||
|
||||
На данный момент поддерживается одна настройка:
|
||||
|
||||
## reweight
|
||||
|
||||
- Тип: число, от 0 до 1
|
||||
- По умолчанию: 1
|
||||
|
||||
Каждый OSD получает число PG, пропорциональное его размеру. Reweight - это
|
||||
множитель для размера, используемый в процессе распределения PG.
|
||||
|
||||
Это значит, что OSD, сконфигурированный с reweight меньше 1 будет получать
|
||||
меньше PG, чем обычно. OSD с reweight, равным 0, не будет участвовать в
|
||||
хранении данных вообще. Вы можете установить reweight в 0, чтобы убрать
|
||||
все данные с OSD.
|
||||
|
||||
# Параметры
|
||||
|
||||
## name
|
||||
|
||||
- Тип: строка
|
||||
- Обязательный
|
||||
|
||||
Название пула.
|
||||
|
||||
## scheme
|
||||
|
||||
- Тип: строка
|
||||
- Обязательный
|
||||
- Возможные значения: "replicated", "xor" или "jerasure"
|
||||
|
||||
Схема избыточности, используемая в данном пуле.
|
||||
|
||||
## pg_size
|
||||
|
||||
- Тип: целое число
|
||||
- Обязательный
|
||||
|
||||
Размер PG данного пула, т.е. число реплик для реплицированных пулов или
|
||||
число дисков данных плюс дисков чётности для пулов EC/XOR.
|
||||
|
||||
## parity_chunks
|
||||
|
||||
- Тип: целое число
|
||||
|
||||
Число дисков чётности для EC/XOR пулов. Иными словами, число дисков, при
|
||||
одновременной потере которых данные будут потеряны.
|
||||
|
||||
Игнорируется для реплицированных пулов, обязательно для EC/XOR.
|
||||
|
||||
## pg_minsize
|
||||
|
||||
- Тип: целое число
|
||||
- Обязательный
|
||||
|
||||
Число доступных дисков для PG данного пула, при котором PG остаются активны.
|
||||
Если становится невозможно размещать новые данные в PG как минимум на pg_minsize
|
||||
OSD, PG деактивируется на чтение и запись. Иными словами, всегда известно,
|
||||
что новые блоки данных всегда записываются как минимум на pg_minsize дисков.
|
||||
|
||||
FIXME: Поведение pg_minsize может быть изменено в будущем с полной деактивации
|
||||
PG на перевод их в режим только для чтения.
|
||||
|
||||
## pg_count
|
||||
|
||||
- Тип: целое число
|
||||
- Обязательный
|
||||
|
||||
Число PG для данного пула. Число должно быть достаточно большим, чтобы монитор
|
||||
мог равномерно распределить по ним данные.
|
||||
|
||||
Обычно это означает примерно 64-128 PG на 1 OSD, т.е. pg_count можно устанавливать
|
||||
равным (общему числу OSD * 100 / pg_size). Значение можно округлить до ближайшей
|
||||
степени 2, чтобы потом было легче уменьшать или увеличивать число PG, умножая
|
||||
или деля его на 2.
|
||||
|
||||
PG в Vitastor эферемерны, то есть вы можете менять их число в любой момент,
|
||||
просто перезаписывая конфигурацию пулов в etcd. Однако объём перемещения данных
|
||||
при этом будет минимален, если новое число PG кратно старому (или наоборот).
|
||||
|
||||
## failure_domain
|
||||
|
||||
- Тип: строка
|
||||
- По умолчанию: host
|
||||
|
||||
Домен отказа для пула. Может быть равен "host" или "osd" или любому другому
|
||||
уровню дерева OSD, задаваемому в настройке [placement_levels](monitor.ru.md#placement_levels).
|
||||
|
||||
Смысл домена отказа в том, что 2 копии, или 2 части одного блока данных в случае
|
||||
кодов коррекции ошибок, никогда не помещаются на OSD, принадлежащие одному домену отказа.
|
||||
Иными словами, домен отказа - это то, от отказа чего вы защищаете себя избыточным
|
||||
хранением.
|
||||
|
||||
## max_osd_combinations
|
||||
|
||||
- Тип: целое число
|
||||
- По умолчанию: 10000
|
||||
|
||||
Алгоритм распределения данных Vitastor основан на решателе задачи линейного
|
||||
программирования. При этом для снижения сложности задачи возможные комбинации OSD
|
||||
генерируются случайно и ограничиваются количеством, равным значению этого параметра.
|
||||
|
||||
Обычно данный параметр не требует изменений.
|
||||
|
||||
## pg_stripe_size
|
||||
|
||||
- Тип: целое число
|
||||
- По умолчанию: 0
|
||||
|
||||
Данный параметр задаёт размер полосы "нарезки" образов на PG. Размер полосы не может
|
||||
быть меньше, чем [block_size](layout-cluster.ru.md#block_size), умноженный на
|
||||
(pg_size - parity_chunks) для EC-пулов или 1 для реплицированных пулов. То же
|
||||
значение используется по умолчанию.
|
||||
|
||||
Это означает, что по умолчанию первые `pg_stripe_size = (block_size * (pg_size-parity_chunks))` байт
|
||||
образа помещаются в одну PG, следующие `pg_stripe_size` байт помещаются в другую
|
||||
и т.п.
|
||||
|
||||
Данный параметр обычно тоже не требует изменений.
|
||||
|
||||
## root_node
|
||||
|
||||
- Тип: строка
|
||||
|
||||
Корневой узел дерева OSD для ограничения OSD, выбираемых для пула. Задаваемый
|
||||
узел должен быть предварительно задан в /vitastor/config/node_placement.
|
||||
|
||||
## osd_tags
|
||||
|
||||
- Тип: строка или массив строк
|
||||
|
||||
Теги OSD для ограничения OSD, выбираемых для пула. Если задаётся несколько тегов
|
||||
массивом, то выбираются только OSD, у которых есть все эти теги.
|
||||
|
||||
## primary_affinity_tags
|
||||
|
||||
- Тип: строка или массив строк
|
||||
|
||||
Теги OSD, по которым должны выбираться OSD, предпочитаемые в качестве первичных
|
||||
для PG этого пула. Имейте в виду, что для EC-пулов Vitastor также всегда
|
||||
предпочитает помещать первичный OSD на один из OSD с данными, а не с чётностью.
|
||||
|
||||
# Примеры
|
||||
|
||||
## Реплицированный пул
|
||||
|
||||
```
|
||||
{
|
||||
"1": {
|
||||
"name":"testpool",
|
||||
"scheme":"replicated",
|
||||
"pg_size":2,
|
||||
"pg_minsize":1,
|
||||
"pg_count":256,
|
||||
"failure_domain":"host"
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
## Пул с кодами коррекции ошибок
|
||||
|
||||
```
|
||||
{
|
||||
"2": {
|
||||
"name":"ecpool",
|
||||
"scheme":"jerasure",
|
||||
"pg_size":3,
|
||||
"parity_chunks":1,
|
||||
"pg_minsize":2,
|
||||
"pg_count":256,
|
||||
"failure_domain":"host"
|
||||
}
|
||||
}
|
||||
```
|
|
@ -1,3 +0,0 @@
|
|||
# Common Parameters
|
||||
|
||||
These are the most common parameters which apply to all components of Vitastor.
|
|
@ -1,3 +0,0 @@
|
|||
# Общие параметры
|
||||
|
||||
Это наиболее общие параметры, используемые всеми компонентами Vitastor.
|
|
@ -1,4 +0,0 @@
|
|||
# Cluster-Wide Disk Layout Parameters
|
||||
|
||||
These parameters apply to clients and OSDs, are fixed at the moment of OSD drive
|
||||
initialization and can't be changed after it without losing data.
|
|
@ -1,4 +0,0 @@
|
|||
# Дисковые параметры уровня кластера
|
||||
|
||||
Данные параметры используются клиентами и OSD, задаются в момент инициализации
|
||||
диска OSD и не могут быть изменены после этого без потери данных.
|
|
@ -1,4 +0,0 @@
|
|||
# OSD Disk Layout Parameters
|
||||
|
||||
These parameters apply to OSDs, are fixed at the moment of OSD drive
|
||||
initialization and can't be changed after it without losing data.
|
|
@ -1,5 +0,0 @@
|
|||
# Дисковые параметры OSD
|
||||
|
||||
Данные параметры используются только OSD и, также как и общекластерные
|
||||
дисковые параметры, задаются в момент инициализации дисков OSD и не могут быть
|
||||
изменены после этого без потери данных.
|
|
@ -1,120 +0,0 @@
|
|||
#!/usr/bin/nodejs
|
||||
|
||||
const fs = require('fs');
|
||||
const yaml = require('yaml');
|
||||
|
||||
const L = {
|
||||
en: {
|
||||
Documentation: 'Documentation',
|
||||
Configuration: 'Configuration',
|
||||
Crossref: 'Read in English',
|
||||
toc_root: '[Documentation](../README.md#documentation)',
|
||||
toc_intro: 'Introduction',
|
||||
toc_installation: 'Installation',
|
||||
toc_config: '[Configuration](../config.en.md)',
|
||||
toc_usage: 'Usage',
|
||||
toc_performance: 'Performance',
|
||||
},
|
||||
ru: {
|
||||
Documentation: 'Документация',
|
||||
Configuration: 'Конфигурация',
|
||||
Type: 'Тип',
|
||||
Default: 'Значение по умолчанию',
|
||||
Minimum: 'Минимальное значение',
|
||||
Crossref: 'Читать на русском',
|
||||
toc_root: '[Документация](../README-ru.md#документация)',
|
||||
toc_intro: 'Введение',
|
||||
toc_installation: 'Установка',
|
||||
toc_config: '[Конфигурация](../config.ru.md)',
|
||||
toc_usage: 'Использование',
|
||||
toc_performance: 'Производительность',
|
||||
},
|
||||
};
|
||||
const types = {
|
||||
en: {
|
||||
string: 'string',
|
||||
bool: 'boolean',
|
||||
int: 'integer',
|
||||
sec: 'seconds',
|
||||
ms: 'milliseconds',
|
||||
us: 'microseconds',
|
||||
},
|
||||
ru: {
|
||||
string: 'строка',
|
||||
bool: 'булево (да/нет)',
|
||||
int: 'целое число',
|
||||
sec: 'секунды',
|
||||
ms: 'миллисекунды',
|
||||
us: 'микросекунды',
|
||||
},
|
||||
};
|
||||
const params_files = fs.readdirSync(__dirname)
|
||||
.filter(f => f.substr(-4) == '.yml')
|
||||
.map(f => f.substr(0, f.length-4));
|
||||
|
||||
for (const file of params_files)
|
||||
{
|
||||
const cfg = yaml.parse(fs.readFileSync(__dirname+'/'+file+'.yml', { encoding: 'utf-8' }));
|
||||
for (const lang in types)
|
||||
{
|
||||
let out = '\n';
|
||||
for (const c of cfg)
|
||||
{
|
||||
out += `\n- [${c.name}](#${c.name})`;
|
||||
}
|
||||
for (const c of cfg)
|
||||
{
|
||||
out += `\n\n## ${c.name}\n\n`;
|
||||
out += `- ${L[lang]['Type'] || 'Type'}: ${c["type_"+lang] || types[lang][c.type] || c.type}\n`;
|
||||
if (c.default !== undefined)
|
||||
out += `- ${L[lang]['Default'] || 'Default'}: ${c.default}\n`;
|
||||
if (c.min !== undefined)
|
||||
out += `- ${L[lang]['Minimum'] || 'Minimum'}: ${c.min}\n`;
|
||||
out += `\n`+(c["info_"+lang] || c["info"]).replace(/\s+$/, '');
|
||||
}
|
||||
const head = fs.readFileSync(__dirname+'/'+file+'.'+lang+'.md', { encoding: 'utf-8' });
|
||||
out = head.replace(/\s+$/, '')+out+"\n";
|
||||
fs.writeFileSync(__dirname+'/../'+file+'.'+lang+'.md', out);
|
||||
}
|
||||
}
|
||||
|
||||
// Add "Read in..." to all other documentation files
|
||||
|
||||
for (const file of find_files(__dirname+'/../..', name => name.substr(-3) == '.md' && !/config\/src\//.exec(name)))
|
||||
{
|
||||
const m = /^(?:(.*?)\/)?([^\/]+)\.([^\.]+)\.[^\.]+$/.exec(file);
|
||||
if (!m)
|
||||
continue;
|
||||
const [ , subdir, filename, lang ] = m;
|
||||
if (!L[lang])
|
||||
continue;
|
||||
let text = fs.readFileSync(__dirname+'/../../'+file, { encoding: 'utf-8' });
|
||||
const title = /(^|\n)# ([^\n]+)/.exec(text)[2];
|
||||
let read_in = Object.keys(L).filter(other => other != lang)
|
||||
.map(other => `[${L[other].Crossref}](${filename}.${other}.md)`)
|
||||
.join(' ')+'\n\n';
|
||||
read_in = L[lang]['toc_root'].replace(/\.\.\//, subdir ? '../../' : '../')+' → '+
|
||||
(subdir ? L[lang]['toc_'+subdir]+' → ' : '')+
|
||||
title+'\n\n-----\n\n'+
|
||||
read_in;
|
||||
if (text.substr(0, read_in.length) != read_in)
|
||||
{
|
||||
fs.writeFileSync(__dirname+'/../../'+file, read_in + (text[0] == '#' ? text : text.replace(/^([\s\S]*?\n)?#/, '#')));
|
||||
}
|
||||
}
|
||||
|
||||
function find_files(dir, fn, subdir = '', res = [])
|
||||
{
|
||||
for (const ent of fs.readdirSync(dir+'/'+subdir, { withFileTypes: true }))
|
||||
{
|
||||
if (ent.isDirectory())
|
||||
{
|
||||
find_files(dir, fn, subdir ? subdir+'/'+ent.name : ent.name, res);
|
||||
}
|
||||
else if (fn(subdir ? subdir+'/'+ent.name : ent.name, ent))
|
||||
{
|
||||
res.push(subdir ? subdir+'/'+ent.name : ent.name);
|
||||
}
|
||||
}
|
||||
return res;
|
||||
}
|
|
@ -1,3 +0,0 @@
|
|||
# Monitor Parameters
|
||||
|
||||
These parameters only apply to Monitors.
|
|
@ -1,3 +0,0 @@
|
|||
# Параметры мониторов
|
||||
|
||||
Данные параметры используются только мониторами Vitastor.
|
|
@ -1,4 +0,0 @@
|
|||
# Network Protocol Parameters
|
||||
|
||||
These parameters apply to clients and OSDs and affect network connection logic
|
||||
between clients, OSDs and etcd.
|
|
@ -1,4 +0,0 @@
|
|||
# Параметры сетевого протокола
|
||||
|
||||
Данные параметры используются клиентами и OSD и влияют на логику сетевого
|
||||
взаимодействия между клиентами, OSD, а также etcd.
|
|
@ -1,4 +0,0 @@
|
|||
# Runtime OSD Parameters
|
||||
|
||||
These parameters only apply to OSDs, are not fixed at the moment of OSD drive
|
||||
initialization and can be changed with an OSD restart.
|
|
@ -1,5 +0,0 @@
|
|||
# Изменяемые параметры OSD
|
||||
|
||||
Данные параметры используются только OSD, но, в отличие от дисковых параметров,
|
||||
не фиксируются в момент инициализации дисков OSD и могут быть изменены в любой
|
||||
момент с перезапуском OSD.
|
|
@ -1,20 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Installation → Kubernetes CSI
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](kubernetes.ru.md)
|
||||
|
||||
# Kubernetes CSI
|
||||
|
||||
Vitastor has a CSI plugin for Kubernetes which supports RWO (and block RWX) volumes.
|
||||
|
||||
To deploy it, take manifests from [csi/deploy/](../../csi/deploy/) directory, put your
|
||||
Vitastor configuration in [001-csi-config-map.yaml](../../csi/deploy/001-csi-config-map.yaml),
|
||||
configure storage class in [009-storage-class.yaml](../../csi/deploy/009-storage-class.yaml)
|
||||
and apply all `NNN-*.yaml` manifests to your Kubernetes installation:
|
||||
|
||||
```
|
||||
for i in ./???-*.yaml; do kubectl apply -f $i; done
|
||||
```
|
||||
|
||||
After that you'll be able to create PersistentVolumes. See example in [csi/deploy/example-pvc.yaml](../../csi/deploy/example-pvc.yaml).
|
|
@ -1,20 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Установка → Kubernetes CSI
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](kubernetes.en.md)
|
||||
|
||||
# Kubernetes CSI
|
||||
|
||||
У Vitastor есть CSI-плагин для Kubernetes, поддерживающий RWO, а также блочные RWX, тома.
|
||||
|
||||
Для установки возьмите манифесты из директории [csi/deploy/](../csi/deploy/), поместите
|
||||
вашу конфигурацию подключения к Vitastor в [csi/deploy/001-csi-config-map.yaml](../csi/deploy/001-csi-config-map.yaml),
|
||||
настройте StorageClass в [csi/deploy/009-storage-class.yaml](../csi/deploy/009-storage-class.yaml)
|
||||
и примените все `NNN-*.yaml` к вашей инсталляции Kubernetes.
|
||||
|
||||
```
|
||||
for i in ./???-*.yaml; do kubectl apply -f $i; done
|
||||
```
|
||||
|
||||
После этого вы сможете создавать PersistentVolume. Пример смотрите в файле [csi/deploy/example-pvc.yaml](../csi/deploy/example-pvc.yaml).
|
|
@ -1,40 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Installation → OpenStack
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](openstack.ru.md)
|
||||
|
||||
# OpenStack
|
||||
|
||||
To enable Vitastor support in an OpenStack installation:
|
||||
|
||||
- Install vitastor-client, patched QEMU and libvirt packages from Vitastor DEB or RPM repository
|
||||
- Use `patches/nova-21.diff` or `patches/nova-23.diff` to patch your Nova installation.
|
||||
Patch 21 fits Nova 21-22, patch 23 fits Nova 23-24.
|
||||
- Install `patches/cinder-vitastor.py` as `..../cinder/volume/drivers/vitastor.py`
|
||||
- Define a volume type in cinder.conf (see below)
|
||||
- Block network access from VMs to Vitastor network (to OSDs and etcd),
|
||||
because Vitastor doesn't support authentication
|
||||
- Restart Cinder and Nova
|
||||
|
||||
Cinder volume type configuration example:
|
||||
|
||||
```
|
||||
[DEFAULT]
|
||||
enabled_backends = lvmdriver-1, vitastor-testcluster
|
||||
# ...
|
||||
|
||||
[vitastor-testcluster]
|
||||
volume_driver = cinder.volume.drivers.vitastor.VitastorDriver
|
||||
volume_backend_name = vitastor-testcluster
|
||||
image_volume_cache_enabled = True
|
||||
volume_clear = none
|
||||
vitastor_etcd_address = 192.168.7.2:2379
|
||||
vitastor_etcd_prefix =
|
||||
vitastor_config_path = /etc/vitastor/vitastor.conf
|
||||
vitastor_pool_id = 1
|
||||
image_upload_use_cinder_backend = True
|
||||
```
|
||||
|
||||
To put Glance images in Vitastor, use [https://docs.openstack.org/cinder/pike/admin/blockstorage-volume-backed-image.html](volume-backed images),
|
||||
although the support has not been verified yet.
|
|
@ -1,40 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Установка → OpenStack
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](openstack.en.md)
|
||||
|
||||
# OpenStack
|
||||
|
||||
Чтобы подключить Vitastor к OpenStack:
|
||||
|
||||
- Установите пакеты vitastor-client, libvirt и QEMU из DEB или RPM репозитория Vitastor
|
||||
- Примените патч `patches/nova-21.diff` или `patches/nova-23.diff` к вашей инсталляции Nova.
|
||||
nova-21.diff подходит для Nova 21-22, nova-23.diff подходит для Nova 23-24.
|
||||
- Скопируйте `patches/cinder-vitastor.py` в инсталляцию Cinder как `cinder/volume/drivers/vitastor.py`
|
||||
- Создайте тип томов в cinder.conf (см. ниже)
|
||||
- Обязательно заблокируйте доступ от виртуальных машин к сети Vitastor (OSD и etcd), т.к. Vitastor (пока) не поддерживает аутентификацию
|
||||
- Перезапустите Cinder и Nova
|
||||
|
||||
Пример конфигурации Cinder:
|
||||
|
||||
```
|
||||
[DEFAULT]
|
||||
enabled_backends = lvmdriver-1, vitastor-testcluster
|
||||
# ...
|
||||
|
||||
[vitastor-testcluster]
|
||||
volume_driver = cinder.volume.drivers.vitastor.VitastorDriver
|
||||
volume_backend_name = vitastor-testcluster
|
||||
image_volume_cache_enabled = True
|
||||
volume_clear = none
|
||||
vitastor_etcd_address = 192.168.7.2:2379
|
||||
vitastor_etcd_prefix =
|
||||
vitastor_config_path = /etc/vitastor/vitastor.conf
|
||||
vitastor_pool_id = 1
|
||||
image_upload_use_cinder_backend = True
|
||||
```
|
||||
|
||||
Чтобы помещать в Vitastor Glance-образы, нужно использовать
|
||||
[https://docs.openstack.org/cinder/pike/admin/blockstorage-volume-backed-image.html](образы на основе томов Cinder),
|
||||
однако, поддержка этой функции ещё не проверялась.
|
|
@ -1,44 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Installation → Packages
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](packages.ru.md)
|
||||
|
||||
# Packages
|
||||
|
||||
## Debian
|
||||
|
||||
- Trust Vitastor package signing key:
|
||||
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
|
||||
- Add Vitastor package repository to your /etc/apt/sources.list:
|
||||
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
|
||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||
- For Debian 10 (Buster) also enable backports repository:
|
||||
`deb http://deb.debian.org/debian buster-backports main`
|
||||
- Install packages: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
|
||||
|
||||
## CentOS
|
||||
|
||||
- Add Vitastor package repository:
|
||||
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
|
||||
- Enable EPEL: `yum/dnf install epel-release`
|
||||
- Enable additional CentOS repositories:
|
||||
- CentOS 7: `yum install centos-release-scl`
|
||||
- CentOS 8: `dnf install centos-release-advanced-virtualization`
|
||||
- Enable elrepo-kernel:
|
||||
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
|
||||
- Install packages: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
|
||||
|
||||
## Installation requirements
|
||||
|
||||
- Linux kernel 5.4 or newer, for io_uring support. 5.8 or later is highly
|
||||
recommended because io_uring is a relatively new technology and there is
|
||||
at least one bug which reproduces with io_uring and HP SmartArray
|
||||
controllers in 5.4
|
||||
- liburing 0.4 or newer
|
||||
- lp_solve
|
||||
- etcd 3.4.15 or newer. Earlier versions won't work because of various bugs,
|
||||
for example [#12402](https://github.com/etcd-io/etcd/pull/12402).
|
||||
- node.js 10 or newer
|
|
@ -1,43 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Установка → Установка из пакетов
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](packages.en.md)
|
||||
|
||||
# Установка из пакетов
|
||||
|
||||
## Debian
|
||||
|
||||
- Добавьте ключ репозитория Vitastor:
|
||||
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
|
||||
- Добавьте репозиторий Vitastor в /etc/apt/sources.list:
|
||||
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
|
||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||
- Для Debian 10 (Buster) также включите репозиторий backports:
|
||||
`deb http://deb.debian.org/debian buster-backports main`
|
||||
- Установите пакеты: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
|
||||
|
||||
## CentOS
|
||||
|
||||
- Добавьте в систему репозиторий Vitastor:
|
||||
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
|
||||
- Включите EPEL: `yum/dnf install epel-release`
|
||||
- Включите дополнительные репозитории CentOS:
|
||||
- CentOS 7: `yum install centos-release-scl`
|
||||
- CentOS 8: `dnf install centos-release-advanced-virtualization`
|
||||
- Включите elrepo-kernel:
|
||||
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
|
||||
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
|
||||
- Установите пакеты: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
|
||||
|
||||
## Установочные требования
|
||||
|
||||
- Ядро Linux 5.4 или новее, для поддержки io_uring. Рекомендуется даже 5.8,
|
||||
так как io_uring - относительно новый интерфейс и в версиях до 5.8 встречались
|
||||
некоторые баги, например, зависание с io_uring и контроллером HP SmartArray
|
||||
- liburing 0.4 или новее
|
||||
- lp_solve
|
||||
- etcd 3.4.15 или новее. Более старые версии не будут работать из-за разных багов,
|
||||
например, [#12402](https://github.com/etcd-io/etcd/pull/12402).
|
||||
- node.js 10 или новее
|
|
@ -1,39 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Installation → Proxmox VE
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](proxmox.ru.md)
|
||||
|
||||
# Proxmox VE
|
||||
|
||||
To enable Vitastor support in Proxmox Virtual Environment (6.4 and 7.1 are supported):
|
||||
|
||||
- Add the corresponding Vitastor Debian repository into sources.list on Proxmox hosts
|
||||
(buster for 6.4, bullseye for 7.1)
|
||||
- Install vitastor-client, pve-qemu-kvm, pve-storage-vitastor (* or see note) packages from Vitastor repository
|
||||
- Define storage in `/etc/pve/storage.cfg` (see below)
|
||||
- Block network access from VMs to Vitastor network (to OSDs and etcd),
|
||||
because Vitastor doesn't support authentication
|
||||
- Restart pvedaemon: `systemctl restart pvedaemon`
|
||||
|
||||
`/etc/pve/storage.cfg` example (the only required option is vitastor_pool, all others
|
||||
are listed below with their default values):
|
||||
|
||||
```
|
||||
vitastor: vitastor
|
||||
# pool to put new images into
|
||||
vitastor_pool testpool
|
||||
# path to the configuration file
|
||||
vitastor_config_path /etc/vitastor/vitastor.conf
|
||||
# etcd address(es), required only if missing in the configuration file
|
||||
vitastor_etcd_address 192.168.7.2:2379/v3
|
||||
# prefix for keys in etcd
|
||||
vitastor_etcd_prefix /vitastor
|
||||
# prefix for images
|
||||
vitastor_prefix pve/
|
||||
# use NBD mounter (only required for containers)
|
||||
vitastor_nbd 0
|
||||
```
|
||||
|
||||
\* Note: you can also manually copy [patches/PVE_VitastorPlugin.pm](patches/PVE_VitastorPlugin.pm) to Proxmox hosts
|
||||
as `/usr/share/perl5/PVE/Storage/Custom/VitastorPlugin.pm` instead of installing pve-storage-vitastor.
|
|
@ -1,39 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Установка → Proxmox
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](proxmox.en.md)
|
||||
|
||||
# Proxmox
|
||||
|
||||
Чтобы подключить Vitastor к Proxmox Virtual Environment (поддерживаются версии 6.4 и 7.1):
|
||||
|
||||
- Добавьте соответствующий Debian-репозиторий Vitastor в sources.list на хостах Proxmox
|
||||
(buster для 6.4, bullseye для 7.1)
|
||||
- Установите пакеты vitastor-client, pve-qemu-kvm, pve-storage-vitastor (* или см. сноску) из репозитория Vitastor
|
||||
- Определите тип хранилища в `/etc/pve/storage.cfg` (см. ниже)
|
||||
- Обязательно заблокируйте доступ от виртуальных машин к сети Vitastor (OSD и etcd), т.к. Vitastor (пока) не поддерживает аутентификацию
|
||||
- Перезапустите демон Proxmox: `systemctl restart pvedaemon`
|
||||
|
||||
Пример `/etc/pve/storage.cfg` (единственная обязательная опция - vitastor_pool, все остальные
|
||||
перечислены внизу для понимания значений по умолчанию):
|
||||
|
||||
```
|
||||
vitastor: vitastor
|
||||
# Пул, в который будут помещаться образы дисков
|
||||
vitastor_pool testpool
|
||||
# Путь к файлу конфигурации
|
||||
vitastor_config_path /etc/vitastor/vitastor.conf
|
||||
# Адрес(а) etcd, нужны, только если не указаны в vitastor.conf
|
||||
vitastor_etcd_address 192.168.7.2:2379/v3
|
||||
# Префикс ключей метаданных в etcd
|
||||
vitastor_etcd_prefix /vitastor
|
||||
# Префикс имён образов
|
||||
vitastor_prefix pve/
|
||||
# Монтировать образы через NBD прокси, через ядро (нужно только для контейнеров)
|
||||
vitastor_nbd 0
|
||||
```
|
||||
|
||||
\* Примечание: вместо установки пакета pve-storage-vitastor вы можете вручную скопировать файл
|
||||
[patches/PVE_VitastorPlugin.pm](patches/PVE_VitastorPlugin.pm) на хосты Proxmox как
|
||||
`/usr/share/perl5/PVE/Storage/Custom/VitastorPlugin.pm`.
|
|
@ -1,65 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Installation → Building from Source
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](source.ru.md)
|
||||
|
||||
# Building from Source
|
||||
|
||||
- [Requirements](#requirements)
|
||||
- [Basic instructions](#basic-instructions)
|
||||
- [QEMU Driver](#qemu-driver)
|
||||
|
||||
## Requirements
|
||||
|
||||
- gcc and g++ 8 or newer, clang 10 or newer, or other compiler with C++11 plus
|
||||
designated initializers support from C++20
|
||||
- CMake
|
||||
- liburing, jerasure headers
|
||||
- tcmalloc (google-perftools-dev)
|
||||
|
||||
## Basic instructions
|
||||
|
||||
Download source, for example using git: `git clone --recurse-submodules https://yourcmc.ru/git/vitalif/vitastor/`
|
||||
|
||||
Get `fio` source and symlink it into `<vitastor>/fio`. If you don't want to build fio engine,
|
||||
you can disable it by passing `-DWITH_FIO=no` to cmake.
|
||||
|
||||
Build and install Vitastor:
|
||||
|
||||
```
|
||||
cd vitastor
|
||||
mkdir build
|
||||
cd build
|
||||
cmake .. && make -j8 install
|
||||
```
|
||||
|
||||
## QEMU Driver
|
||||
|
||||
It's recommended to build the QEMU driver (qemu_driver.c) in-tree, as a part of
|
||||
QEMU build process. To do that:
|
||||
- Install vitastor client library headers (from source or from vitastor-client-dev package)
|
||||
- Take a corresponding patch from `patches/qemu-*-vitastor.patch` and apply it to QEMU source
|
||||
- Copy `src/qemu_driver.c` to QEMU source directory as `block/block-vitastor.c`
|
||||
- Build QEMU as usual
|
||||
|
||||
But it is also possible to build it out-of-tree. To do that:
|
||||
- Get QEMU source, begin to build it, stop the build and copy headers:
|
||||
- `<qemu>/include` → `<vitastor>/qemu/include`
|
||||
- Debian:
|
||||
* Use qemu packages from the main repository
|
||||
* `<qemu>/b/qemu/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* `<qemu>/b/qemu/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
- CentOS 8:
|
||||
* Use qemu packages from the Advanced-Virtualization repository. To enable it, run
|
||||
`yum install centos-release-advanced-virtualization.noarch` and then `yum install qemu`
|
||||
* `<qemu>/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* For QEMU 3.0+: `<qemu>/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
* For QEMU 2.0+: `<qemu>/qapi-types.h` → `<vitastor>/qemu/b/qemu/qapi-types.h`
|
||||
- `config-host.h` and `qapi` are required because they contain generated headers
|
||||
- Configure Vitastor with `WITH_QEMU=yes` and, if you're on RHEL, also with `QEMU_PLUGINDIR=qemu-kvm`:
|
||||
`cmake .. -DWITH_QEMU=yes`.
|
||||
- After that, Vitastor will build `block-vitastor.so` during its build process.
|
||||
- This way you can use the driver even with unmodified QEMU, but you'll need to set
|
||||
environment variable `LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so`
|
||||
and Vitastor disks won't work in QAPI and in "new" JSON syntax `-blockdev` in this case.
|
|
@ -1,68 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Установка → Сборка из исходных кодов
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](source.en.md)
|
||||
|
||||
# Сборка из исходных кодов
|
||||
|
||||
- [Требования](#требования)
|
||||
- [Базовая инструкция](#базовая-инструкция)
|
||||
- [Драйвер QEMU](#драйвер-qemu)
|
||||
|
||||
## Требования
|
||||
|
||||
- gcc и g++ >= 8, либо clang >= 10, либо другой компилятор с поддержкой C++11 плюс
|
||||
назначенных инициализаторов (designated initializers) из C++20
|
||||
- CMake
|
||||
- Заголовки liburing, jerasure
|
||||
- tcmalloc (google-perftools-dev)
|
||||
|
||||
## Базовая инструкция
|
||||
|
||||
Скачайте исходные коды, например, из git: `git clone --recurse-submodules https://yourcmc.ru/git/vitalif/vitastor/`
|
||||
|
||||
Скачайте исходные коды пакета `fio`, распакуйте их и создайте символическую ссылку на них
|
||||
в директории исходников Vitastor: `<vitastor>/fio`. Либо, если вы не хотите собирать плагин fio,
|
||||
его можно исключить из сборки путём передачи `-DWITH_FIO=no` в cmake.
|
||||
|
||||
Собрать и установить Vitastor:
|
||||
|
||||
```
|
||||
cd vitastor
|
||||
mkdir build
|
||||
cd build
|
||||
cmake .. && make -j8 install
|
||||
```
|
||||
|
||||
## Драйвер QEMU
|
||||
|
||||
Драйвер QEMU (qemu_driver.c) рекомендуется собирать вместе с самим QEMU. Для этого:
|
||||
- Установите заголовки клиентской библиотеки Vitastor (из исходников или из пакета vitastor-client-dev)
|
||||
- Возьмите соответствующий патч из `patches/qemu-*-vitastor.patch` и примените его к исходникам QEMU
|
||||
- Скопируйте [src/qemu_driver.c](../../src/qemu_driver.c) в директорию исходников QEMU как `block/block-vitastor.c`
|
||||
- Соберите QEMU как обычно
|
||||
|
||||
Однако в целях отладки драйвер также можно собирать отдельно от QEMU. Для этого:
|
||||
- Установите QEMU, возьмите исходные коды установленного пакета, начните его пересборку,
|
||||
через некоторое время остановите её и скопируйте следующие заголовки:
|
||||
- `<qemu>/include` → `<vitastor>/qemu/include`
|
||||
- Debian:
|
||||
* Берите qemu из основного репозитория
|
||||
* `<qemu>/b/qemu/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* `<qemu>/b/qemu/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
- CentOS 8:
|
||||
* Берите qemu из репозитория Advanced-Virtualization. Чтобы включить его, запустите
|
||||
`yum install centos-release-advanced-virtualization.noarch` и далее `yum install qemu`
|
||||
* `<qemu>/config-host.h` → `<vitastor>/qemu/b/qemu/config-host.h`
|
||||
* Для QEMU 3.0+: `<qemu>/qapi` → `<vitastor>/qemu/b/qemu/qapi`
|
||||
* Для QEMU 2.0+: `<qemu>/qapi-types.h` → `<vitastor>/qemu/b/qemu/qapi-types.h`
|
||||
- `config-host.h` и `qapi` нужны, т.к. в них содержатся автогенерируемые заголовки
|
||||
- Сконфигурируйте cmake Vitastor с `WITH_QEMU=yes` (`cmake .. -DWITH_QEMU=yes`) и, если вы
|
||||
используете RHEL-подобый дистрибутив, также с `QEMU_PLUGINDIR=qemu-kvm`.
|
||||
- После этого в процессе сборки Vitastor также будет собираться подходящий для вашей
|
||||
версии QEMU `block-vitastor.so`.
|
||||
- Таким образом можно использовать драйвер даже с немодифицированным QEMU, но в этом случае
|
||||
диски Vitastor не будут работать через QAPI и через JSON-синтаксис `-blockdev`, а также
|
||||
потребуется устанавливать переменную окружения
|
||||
`LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so`.
|
|
@ -1,91 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Introduction → Architecture
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](architecture.ru.md)
|
||||
|
||||
# Architecture
|
||||
|
||||
- [Basic concepts](#basic-concepts)
|
||||
- [Similarities to Ceph](#similarities-to-ceph)
|
||||
- [Differences from Ceph](#differences-from-ceph)
|
||||
- [Implementation Principles](#implementation-principles)
|
||||
|
||||
## Basic concepts
|
||||
|
||||
- OSD (Object Storage Daemon) is a process that stores data and serves read/write requests.
|
||||
- PG (Placement Group) is a "shard" of the cluster, group of data stored on one set of replicas.
|
||||
- Pool is a container for data that has equal redundancy scheme and placement rules.
|
||||
- Monitor is a separate daemon that watches cluster state and handles failures.
|
||||
- Failure Domain is a group of OSDs that you allow to fail. It's "host" by default.
|
||||
- Placement Tree groups OSDs in a hierarchy to later split them into Failure Domains.
|
||||
|
||||
## Similarities to Ceph
|
||||
|
||||
- Vitastor also has Pools, PGs, OSDs, Monitors, Failure Domains, Placement Tree:
|
||||
- Vitastor also distributes every image data across the whole cluster.
|
||||
- Vitastor is also transactional. Even though there's a "lazy fsync mode" which
|
||||
doesn't implicitly flush every operation to disks, every write to the cluster is atomic.
|
||||
- OSDs also have journal and metadata and they can also be put on separate drives.
|
||||
- Just like in Ceph, client library attempts to recover from any cluster failure so
|
||||
you can basically reboot the whole cluster and only pause, but not crash, your clients.
|
||||
|
||||
## Differences from Ceph
|
||||
|
||||
- Vitastor's primary focus is on SSDs: SSD-only and SSD+HDD clusters.
|
||||
- The basic layer of Vitastor is block storage with fixed-size blocks, not object storage with
|
||||
rich semantics like in Ceph (RADOS).
|
||||
- PGs are ephemeral in Vitastor. This means that they aren't stored on data disks and only exist
|
||||
in memory while OSDs are running.
|
||||
- Vitastor OSD is (and will always be) single-threaded. If you want to dedicate more than 1 core
|
||||
per drive you should run multiple OSDs each on a different partition of the drive.
|
||||
Vitastor isn't CPU-hungry though (as opposed to Ceph), so 1 core is sufficient in a lot of cases.
|
||||
- Metadata is always kept in memory which removes the need for extra disk reads. Metadata size
|
||||
depends linearly on drive capacity and data store block size which is 128 KB by default.
|
||||
With 128 KB blocks metadata takes around 512 MB per 1 TB (which is still less than Ceph wants).
|
||||
Journal is also kept in memory by default, but in SSD-only clusters it's only 32 MB, and in SSD+HDD
|
||||
clusters, where it's beneficial to increase it, [inmemory_journal](docs/config/osd.en.md#inmemory_journal) can be disabled.
|
||||
- Vitastor storage layer doesn't have internal copy-on-write or redirect-write. I know that maybe
|
||||
it's possible to create a good copy-on-write storage, but it's much harder and makes performance
|
||||
less deterministic, so CoW isn't used in Vitastor.
|
||||
- There's a "lazy fsync" mode which allows to batch writes before flushing them to the disk.
|
||||
This allows to use Vitastor with desktop SSDs, but still lowers performance due to additional
|
||||
network roundtrips, so use server SSDs with capacitor-based power loss protection
|
||||
("Advanced Power Loss Protection") for best performance.
|
||||
- Recovery process is per-object (per-block), not per-PG. Also there are no PGLOGs.
|
||||
- Monitors don't store data. Cluster configuration and state is stored in etcd in simple human-readable
|
||||
JSON structures. Monitors only watch cluster state and handle data movement.
|
||||
Thus Vitastor's Monitor isn't a critical component of the system and is more similar to Ceph's Manager.
|
||||
Vitastor's Monitor is implemented in node.js.
|
||||
- PG distribution isn't based on consistent hashes. All PG mappings are stored in etcd.
|
||||
Rebalancing PGs between OSDs is done by mathematical optimization - data distribution problem
|
||||
is reduced to a linear programming problem and solved by lp_solve. This allows for almost
|
||||
perfect (96-99% uniformity compared to Ceph's 80-90%) data distribution in most cases, ability
|
||||
to map PGs by hand without breaking rebalancing logic, reduced OSD peer-to-peer communication
|
||||
(on average, OSDs have fewer peers) and less data movement. It also probably has a drawback -
|
||||
this method may fail in very large clusters, but up to several hundreds of OSDs it's perfectly fine.
|
||||
It's also easy to add consistent hashes in the future if something proves their necessity.
|
||||
- There's no separate CRUSH layer. You select pool redundancy scheme, placement root, failure domain
|
||||
and so on directly in pool configuration.
|
||||
|
||||
## Implementation Principles
|
||||
|
||||
- I like architecturally simple solutions. Vitastor is and will always be designed
|
||||
exactly like that.
|
||||
- I also like reinventing the wheel to some extent, like writing my own HTTP client
|
||||
for etcd interaction instead of using prebuilt libraries, because in this case
|
||||
I'm confident about what my code does and what it doesn't do.
|
||||
- I don't care about C++ "best practices" like RAII or proper inheritance or usage of
|
||||
smart pointers or whatever and I don't intend to change my mind, so if you're here
|
||||
looking for ideal reference C++ code, this probably isn't the right place.
|
||||
- I like node.js better than any other dynamically-typed language interpreter
|
||||
because it's faster than any other interpreter in the world, has neutral C-like
|
||||
syntax and built-in event loop. That's why Monitor is implemented in node.js.
|
||||
|
||||
## Known Problems
|
||||
|
||||
- Deleting images in a degraded cluster may currently lead to objects reappearing
|
||||
after dead OSDs come back, and in case of erasure-coded pools, they may even
|
||||
reappear as incomplete. Just repeat the removal request again in this case.
|
||||
This problem will be fixed in the nearest future, the fix is already implemented
|
||||
in the "epoch-deletions" branch.
|
|
@ -1,208 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Введение → Архитектура
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](architecture.en.md)
|
||||
|
||||
# Архитектура
|
||||
|
||||
Краткое описание архитектуры Vitastor.
|
||||
|
||||
- [Серверные компоненты](#серверные-компоненты)
|
||||
- [Базовые понятия](#базовые-понятия)
|
||||
- [Клиентские компоненты](#клиентские-компоненты)
|
||||
- [Общий процесс записи и чтения](#общий-процесс-записи-и-чтения)
|
||||
- [Особенности обработки запросов](#особенности-обработки-запросов)
|
||||
- [Схожесть с Ceph](#схожесть-с-ceph)
|
||||
- [Отличия от Ceph](#отличия-от-ceph)
|
||||
- [Принципы разработки](#принципы-разработки)
|
||||
|
||||
## Серверные компоненты
|
||||
|
||||
- **OSD** (Object Storage Daemon) — процесс, который непосредственно работает с диском, пишет и читает данные.
|
||||
Один OSD управляет одним диском (или разделом). OSD общаются с etcd и друг с другом — от etcd они
|
||||
получают состояние кластера, а друг другу передают запросы записи и чтения вторичных копий данных.
|
||||
- **etcd** — кластерная key/value база данных, используется для хранения настроек и верхнеуровневого
|
||||
состояния кластера, а также предотвращения разделения сознания. Блоки данных в etcd не хранятся,
|
||||
в обработке клиентских запросов чтения и записи etcd не участвует.
|
||||
- **Монитор** — отдельный демон на node.js, рассчитывающий необходимые изменения в конфигурацию
|
||||
кластера, сохраняющий эту информацию в etcd и таким образом командующий OSD применить эти изменения.
|
||||
Также агрегирует статистику. Контактирует только с etcd, OSD с монитором не общаются.
|
||||
|
||||
## Базовые понятия
|
||||
|
||||
- **Пул (Pool)** — контейнер для данных, имеющих одну и ту же схему избыточности и правила распределения по OSD.
|
||||
- **PG (Placement Group)** — "шард", единица деления пулов в кластере, которой назначается свой набор
|
||||
OSD для хранения данных (копий или частей объектов).
|
||||
- **Домен отказа (Failure Domain)** — группа OSD, одновременное падение которых рассматривается
|
||||
как вероятное. По умолчанию это "host" (сервер).
|
||||
- **Дерево распределения** (Placement Tree, в Ceph CRUSH Tree) — иерархическая группировка OSD
|
||||
в узлы, которые далее можно использовать как домены отказа.
|
||||
|
||||
## Клиентские компоненты
|
||||
|
||||
- **Клиентская библиотека** — инкапсулирует логику на стороне клиента. Соединяются с etcd и со всеми OSD,
|
||||
от etcd получают состояние кластера, команды чтения и записи отправляют на все OSD напрямую.
|
||||
В силу архитектуры все отдельные блоки данных (по умолчанию по 128 КБ) располагается на разных
|
||||
OSD, но клиент устроен так, что всегда точно знает, к какому OSD обращаться, и подключается
|
||||
к нему напрямую.
|
||||
|
||||
На базе клиентской библиотеки реализованы все остальные клиенты:
|
||||
|
||||
- **vitastor-cli** — утилита командной строки для управления кластером. В данный момент позволяет
|
||||
просматривать общее состояние кластера и управлять образами — т.е. создавать, менять и удалять
|
||||
виртуальные диски, их снимки и клоны.
|
||||
- **Драйвер QEMU** — подключаемый модуль QEMU, позволяющий QEMU/KVM виртуальным машинам работать
|
||||
с виртуальными дисками Vitastor напрямую из пространства пользователя с помощью клиентской
|
||||
библиотеки, без необходимости отображения дисков в виде блочных устройств.
|
||||
- **vitastor-nbd** — утилита, позволяющая монтировать образы Vitastor в виде блочных устройств
|
||||
с помощью NBD (Network Block Device), на самом деле скорее работающего как "BUSE"
|
||||
(Block Device In Userspace). Модуля ядра Linux для выполнения той же задачи в Vitastor нет
|
||||
(по крайней мере, пока).
|
||||
- **CSI драйвер** — драйвер для подключения Vitastor-образов в виде персистентных томов (PV) Kubernetes.
|
||||
Работает через vitastor-nbd — образы отражаются в виде блочных устройств и монтируются
|
||||
в контейнеры.
|
||||
- **Драйвера Proxmox, OpenStack и т.п.** — подключаемые модули для соответствующих систем,
|
||||
позволяющие использовать Vitastor как хранилище в оных.
|
||||
- **vitastor-nfs** — утилита, предоставляющая файловый доступ к образам в кластере Vitastor
|
||||
по протоколу NFS 3.0. Предназначена для гипервизоров, не основанных на QEMU и Linux, но при
|
||||
этом поддерживающих NFS.
|
||||
|
||||
## Общий процесс записи и чтения
|
||||
|
||||
- В Vitastor хранятся виртуальные диски, также называемые "образы" или "иноды".
|
||||
- Каждый образ хранится в определённом пуле. Пул определяет параметры хранения образов в нём,
|
||||
такие, как схему избыточности (репликация или EC — коды коррекции ошибок), домен отказа
|
||||
и ограничения по выбору OSD для размещения данных образов. См. [Конфигурация пулов](../config/pool.ru.md).
|
||||
- Каждый образ разбивается на объекты фиксированного размера, равного [block_size](../config/layout-cluster.ru.md#block_size)
|
||||
(по умолчанию 128 КБ), умноженному на число частей данных для EC или на 1 для реплик.
|
||||
То есть, например, если в пуле используется схема кодирования 4+2 (4 части данных + 2 чётности),
|
||||
то при стандартном block_size образы разбиваются на части по 512 КБ.
|
||||
- Клиентские запросы чтения/записи разделяются на части, соответствующие этим объектам.
|
||||
- Для каждого объекта определяется номер PG, которой он принадлежит, путём простого взятия
|
||||
остатка от деления ID образа и смещения на число PG в пуле, которому принадлежит образ.
|
||||
- Клиент читает информацию о первичном OSD всех PG из etcd. Первичный OSD каждой PG назначается
|
||||
монитором в процессе работы кластера, вместе с текущим целевым набором OSD этой PG.
|
||||
- Клиент соединяется (если ещё не соединён) с первичными OSD всех PG, объекты которых участвуют
|
||||
в запросе и одновременно отправляет им запросы чтения/записи частей.
|
||||
- Если какие-то из первичных OSD недоступны, клиент повторяет попытки соединения бесконечно до
|
||||
тех пор, пока они не станут доступны или пока PG не будут назначены другие первичные OSD.
|
||||
- Клиент также повторяет запросы, если первичные OSD отвечают кодом ошибки EPIPE, означающим,
|
||||
что запрос не может быть обработан в данный момент. Это происходит, если PG либо не активна
|
||||
вообще, либо не активна на данном OSD в данный момент (например, если в этот момент меняется
|
||||
её первичный OSD) или если в процессе обработки запроса сам первичный OSD теряет подключение
|
||||
к репликам.
|
||||
- Первичный OSD определяет, на каких OSD находятся части объекта. По умолчанию все объекты
|
||||
считаются находящимися на текущем целевом наборе OSD соответствующей PG, но какие-то могут
|
||||
находиться на других OSD, если эти объекты деградированы или перемещены, или идёт процесс
|
||||
ребаланса. Запросы для проверки по сети не отправляются, информация о местоположении всех
|
||||
объектов рассчитывается первичным OSD при активации PG и хранится в памяти.
|
||||
- Первичный OSD соединяется (если ещё не соединён) с вторичными OSD, на которых располагаются
|
||||
части объекта, и отправляет им запросы чтения/записи, а также читает/пишет из/в своё локальное
|
||||
хранилище, если сам входит в набор.
|
||||
- После завершения всех вторичных операций чтения/записи первичный OSD отправляет ответ клиенту.
|
||||
|
||||
### Особенности обработки запросов
|
||||
|
||||
- Если в пуле используются коды коррекции ошибок и при этом часть OSD недоступна, первичный
|
||||
OSD при чтении восстанавливает данные из оставшихся частей.
|
||||
- Каждый объект имеет номер версии. При записи объекта первичный OSD сначала читает из номер
|
||||
версии объекта. Так как первичный OSD обычно сам хранит копию или часть объекта, номер
|
||||
версии обычно читается из памяти самого OSD. Однако, если ни одна часть обновляемого объекта
|
||||
не находится на первичном OSD, для получения номера версии он обращается к одному из вторичных
|
||||
OSD, на которых копия объекта есть. Обращения к диску при этом всё равно не происходит,
|
||||
так как метаданные объектов, включая номер версии, все OSD хранят в памяти.
|
||||
- Если в пуле используются коды коррекции ошибок, перед частичной записью объекта для вычисления
|
||||
чётности зачастую требуется чтение частей объекта с вторичных OSD или с локального диска
|
||||
самого первичного OSD.
|
||||
- Также, если в пуле используются коды коррекции ошибок, для закрытия Write Hole применяется
|
||||
двухфазный алгоритм записи: сначала на все вторичные OSD записывается новая версия частей
|
||||
объекта, но при этом старая версия не удаляется, а потом, после получения подтверждения
|
||||
успешной записи от всех вторичных OSD, новая версия фиксируется и разрешается удаление старой.
|
||||
- Если в кластере не включён режим immediate_commit, то запросы записи, отправляемые клиентами,
|
||||
не считаются зафиксированными на физических накопителях сразу. Для фиксации данных клиенты
|
||||
должны отдельно отправлять запросы SYNC (отдельный от чтения и записи вид запроса),
|
||||
а пока такой запрос не отправлен, считается, что записанные данные могут исчезнуть,
|
||||
если соответствующий OSD упадёт. Поэтому, когда режим immediate_commit отключён, все
|
||||
запросы записи клиенты копируют в памяти и при потере соединения и повторном соединении
|
||||
с OSD повторяют из памяти. Скопированные в память данные удаляются при успешном fsync,
|
||||
а чтобы хранение этих данных не приводило к чрезмерному потреблению памяти, клиенты
|
||||
автоматически выполняют fsync каждые [client_dirty_limit](../config/layout-cluster.ru.md#client_dirty_limit)
|
||||
записанных байт.
|
||||
|
||||
## Схожесть с Ceph
|
||||
|
||||
- В Vitastor тоже есть пулы (pools), PG, OSD, мониторы, домены отказы, дерево распределения (аналог crush-дерева).
|
||||
- Vitastor тоже равномерно распределяет данные каждого образа по всем PG пула.
|
||||
- Vitastor тоже транзакционный, то есть, каждая запись в кластер атомарна.
|
||||
- У Vitastor OSD тоже есть журнал и метаданные и их тоже можно размещать на отдельном диске.
|
||||
- Как и в Ceph, клиентская библиотека пытается дождаться восстановления работы
|
||||
при любом полном или частичном отказе кластера, то есть, вы можете перезагрузить
|
||||
хоть весь кластер разом, и клиенты не отключатся, только на время зависнут.
|
||||
|
||||
## Отличия от Ceph
|
||||
|
||||
- Vitastor в первую очередь сфокусирован на использовании с SSD: либо в кластерах на основе
|
||||
только SSD, либо гибридных (HDD с журналами на SSD).
|
||||
- Базовый слой Vitastor — простое блочное хранилище с блоками фиксированного размера, а не
|
||||
объектное со сложной семантикой, как в Ceph (RADOS).
|
||||
- PG в Vitastor эфемерны. Это означает, что они не хранятся на дисках и существуют только в
|
||||
памяти работающих OSD.
|
||||
- Vitastor OSD однопоточные и всегда такими останутся. Если вам нужно выделить больше 1 ядра
|
||||
на 1 диск — создайте несколько OSD на разделах этого диска. Нужно это в основном для NVMe,
|
||||
так как Vitastor не потребляет много ресурсов CPU.
|
||||
- Метаданные всегда размещаются в памяти, благодаря чему никогда не тратится лишнее время
|
||||
на чтение метаданных с диска. Объём метаданных линейно зависит от ёмкости диска и размера
|
||||
блока хранилища (block_size, по умолчанию 128 КБ). С 128 КБ блоком потребление памяти
|
||||
составляет примерно 512 МБ на 1 ТБ данных. Журналы по умолчанию тоже хранятся в памяти,
|
||||
но в SSD-кластерах нужный размер журнала составляет всего 32 МБ, а в гибридных (SSD+HDD)
|
||||
кластерах, в которых есть смысл делать журналы больше, можно отключить [inmemory_journal](../docs/config/osd.ru.md#inmemory_journal).
|
||||
- В Vitastor нет внутреннего copy-on-write. Я считаю, что реализация CoW-хранилища гораздо сложнее,
|
||||
поэтому сложнее добиться устойчиво хороших результатов. Возможно, в один прекрасный день
|
||||
я придумаю красивый алгоритм для CoW-хранилища, но пока нет — внутреннего CoW в Vitastor не будет.
|
||||
Всё это не относится к "внешнему" CoW (снапшотам и клонам).
|
||||
- В Vitastor есть режим "ленивых fsync", в котором OSD группирует запросы записи перед сбросом их
|
||||
на диск, что позволяет получить лучшую производительность с дешёвыми настольными SSD без конденсаторов
|
||||
("Advanced Power Loss Protection" / "Capacitor-Based Power Loss Protection").
|
||||
Тем не менее, такой режим всё равно медленнее использования нормальных серверных SSD и мгновенного
|
||||
fsync, так как приводит к дополнительным операциям передачи данных по сети, поэтому рекомендуется
|
||||
всё-таки использовать хорошие серверные диски, тем более, стоят они почти так же, как десктопные.
|
||||
- Процессы восстановления оперируют отдельными объектами, а не целыми PG.
|
||||
- "Мониторы" не хранят данные. Конфигурация и состояние кластера хранятся в etcd в простых человекочитаемых
|
||||
JSON-структурах. Мониторы Vitastor только следят за состоянием кластера и управляют перемещением данных.
|
||||
В этом смысле монитор Vitastor не является критичным компонентом системы и больше похож на Ceph-овский
|
||||
менеджер (MGR). Монитор Vitastor написан на node.js.
|
||||
- Распределение PG не основано на консистентных хешах. Вместо этого все маппинги PG хранятся прямо в etcd
|
||||
(ибо нет никакой проблемы сохранить несколько сотен-тысяч записей в памяти, а не считать каждый раз хеши).
|
||||
Перераспределение PG по OSD выполняется через математическую оптимизацию,
|
||||
а конкретно, сведение задачи к ЛП (задаче линейного программирования) и решение оной с помощью утилиты
|
||||
lp_solve. Такой подход позволяет обычно выравнивать распределение места почти идеально — равномерность
|
||||
обычно составляет 96-99%, в отличие от Ceph, где на голом CRUSH-е без балансировщика обычно выходит 80-90%.
|
||||
Также это позволяет минимизировать объём перемещения данных и случайность связей между OSD, а также менять
|
||||
распределение вручную, не боясь сломать логику перебалансировки. В таком подходе есть и потенциальный
|
||||
недостаток — есть предположение, что в очень большом кластере он может сломаться — однако вплоть до
|
||||
нескольких сотен OSD подход точно работает нормально. Ну и, собственно, при необходимости легко
|
||||
реализовать и консистентные хеши.
|
||||
- Отдельный слой, подобный слою "CRUSH-правил", отсутствует. Вы настраиваете схемы отказоустойчивости,
|
||||
домены отказа и правила выбора OSD напрямую в конфигурации пулов.
|
||||
|
||||
## Принципы разработки
|
||||
|
||||
- Я люблю простые решения. Поэтому Vitastor простой и быстрый и всегда будет таковым.
|
||||
- Я не против иногда изобрести велосипед, например, собственный простенький HTTP-клиент
|
||||
для работы с etcd, вместо того, чтобы взять тяжёлую готовую библиотеку, ибо в данном
|
||||
случае я точно уверен в том, что знаю, что делает код.
|
||||
- Общепринятые практики написания C++ кода с RAII, наследованием, умными указателями
|
||||
и так далее меня также не волнуют, поэтому если вы хотели увидеть здесь красивый
|
||||
идиоматичный C++ код, вы, вероятно, пришли не по адресу.
|
||||
- Из всех интерпретаторов скриптоты больше всех я люблю node.js, это самый быстрый в мире
|
||||
интерпретатор, у него есть встроенная событийная машина, развитая инфраструктура и
|
||||
приятный нейтральный C-подобный язык программирования. Поэтому Монитор реализован на node.js.
|
||||
|
||||
## Известные проблемы
|
||||
|
||||
- Удаление образов в деградированном кластере может в данный момент приводить к повторному
|
||||
"появлению" удалённых объектов после поднятия отключённых OSD, причём в случае EC-пулов,
|
||||
объекты могут появиться в виде "неполных". Если вы столкнётесь с такой ситуацией, просто
|
||||
повторите запрос удаления. Исправление этой проблемы уже реализовано в ветке "epoch-deletions"
|
||||
и вскоре будет включено в релиз.
|
|
@ -1,37 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Introduction → Author and License
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](author.ru.md)
|
||||
|
||||
# Author and License
|
||||
|
||||
Copyright (c) Vitaliy Filippov (vitalif [at] yourcmc.ru), 2019+
|
||||
|
||||
Join Vitastor Telegram Chat: https://t.me/vitastor
|
||||
|
||||
All server-side code (OSD, Monitor and so on) is licensed under the terms of
|
||||
Vitastor Network Public License 1.1 (VNPL 1.1), a copyleft license based on
|
||||
GNU GPLv3.0 with the additional "Network Interaction" clause which requires
|
||||
opensourcing all programs directly or indirectly interacting with Vitastor
|
||||
through a computer network and expressly designed to be used in conjunction
|
||||
with it ("Proxy Programs"). Proxy Programs may be made public not only under
|
||||
the terms of the same license, but also under the terms of any GPL-Compatible
|
||||
Free Software License, as listed by the Free Software Foundation.
|
||||
This is a stricter copyleft license than the Affero GPL.
|
||||
|
||||
Please note that VNPL doesn't require you to open the code of proprietary
|
||||
software running inside a VM if it's not specially designed to be used with
|
||||
Vitastor.
|
||||
|
||||
Basically, you can't use the software in a proprietary environment to provide
|
||||
its functionality to users without opensourcing all intermediary components
|
||||
standing between the user and Vitastor or purchasing a commercial license
|
||||
from the author 😀.
|
||||
|
||||
Client libraries (cluster_client and so on) are dual-licensed under the same
|
||||
VNPL 1.1 and also GNU GPL 2.0 or later to allow for compatibility with GPLed
|
||||
software like QEMU and fio.
|
||||
|
||||
You can find the full text of VNPL-1.1 in the file [VNPL-1.1.txt](../../VNPL-1.1.txt).
|
||||
GPL 2.0 is also included in this repository as [GPL-2.0.txt](../../GPL-2.0.txt).
|
|
@ -1,37 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Введение → Автор и лицензия
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](author.en.md)
|
||||
|
||||
# Автор и лицензия
|
||||
|
||||
Автор: Виталий Филиппов (vitalif [at] yourcmc.ru), 2019+
|
||||
|
||||
Заходите в Telegram-чат Vitastor: https://t.me/vitastor
|
||||
|
||||
Лицензия: VNPL 1.1 на серверный код и двойная VNPL 1.1 + GPL 2.0+ на клиентский.
|
||||
|
||||
VNPL - "сетевой копилефт", собственная свободная копилефт-лицензия
|
||||
Vitastor Network Public License 1.1, основанная на GNU GPL 3.0 с дополнительным
|
||||
условием "Сетевого взаимодействия", требующим распространять все программы,
|
||||
специально разработанные для использования вместе с Vitastor и взаимодействующие
|
||||
с ним по сети, под лицензией VNPL или под любой другой свободной лицензией.
|
||||
|
||||
Идея VNPL - расширение действия копилефта не только на модули, явным образом
|
||||
связываемые с кодом Vitastor, но также на модули, оформленные в виде микросервисов
|
||||
и взаимодействующие с ним по сети.
|
||||
|
||||
Таким образом, если вы хотите построить на основе Vitastor сервис, содержаший
|
||||
компоненты с закрытым кодом, взаимодействующие с Vitastor, вам нужна коммерческая
|
||||
лицензия от автора 😀.
|
||||
|
||||
На Windows и любое другое ПО, не разработанное *специально* для использования
|
||||
вместе с Vitastor, никакие ограничения не накладываются.
|
||||
|
||||
Клиентские библиотеки распространяются на условиях двойной лицензии VNPL 1.0
|
||||
и также на условиях GNU GPL 2.0 или более поздней версии. Так сделано в целях
|
||||
совместимости с таким ПО, как QEMU и fio.
|
||||
|
||||
Вы можете найти полный текст VNPL 1.1 в файле [VNPL-1.1.txt](../../VNPL-1.1.txt),
|
||||
а GPL 2.0 в файле [GPL-2.0.txt](../../GPL-2.0.txt).
|
|
@ -1,62 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Introduction → Features
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](features.ru.md)
|
||||
|
||||
# Features
|
||||
|
||||
- [Server-side features](#server-side-features)
|
||||
- [Plugins and tools](#plugins-and-tools)
|
||||
- [Roadmap](#roadmap)
|
||||
|
||||
## Server-side features
|
||||
|
||||
- Basic part: highly-available block storage with symmetric clustering and no SPOF
|
||||
- [Performance](../performance/comparison1.en.md) ;-D
|
||||
- [Multiple redundancy schemes](../config/pool.en.md#scheme): Replication, XOR n+1, Reed-Solomon erasure codes
|
||||
based on jerasure library with any number of data and parity drives in a group
|
||||
- Configuration via simple JSON data structures in etcd (parameters, pools and images)
|
||||
- Automatic data distribution over OSDs, with support for:
|
||||
- Mathematical optimization for better uniformity and less data movement
|
||||
- Multiple pools
|
||||
- Placement tree, OSD selection by tags (device classes) and placement root
|
||||
- Configurable failure domains
|
||||
- Recovery of degraded blocks
|
||||
- Rebalancing (data movement between OSDs)
|
||||
- [Lazy fsync support](../config/layout-cluster.en.md#immediate_commit)
|
||||
- Per-OSD and per-image I/O and space usage statistics in etcd
|
||||
- Snapshots and copy-on-write image clones
|
||||
- [Write throttling to smooth random write workloads in SSD+HDD configurations](../config/osd.en.md#throttle_small_writes)
|
||||
- [RDMA/RoCEv2 support via libibverbs](../config/network.en.md#rdma_device)
|
||||
|
||||
## Plugins and tools
|
||||
|
||||
- [Debian and CentOS packages](../installation/packages.en.md)
|
||||
- [Image management CLI (vitastor-cli)](../usage/cli.en.md)
|
||||
- Generic user-space client library
|
||||
- [Native QEMU driver](../usage/qemu.en.md)
|
||||
- [Loadable fio engine for benchmarks](../usage/fio.en.md)
|
||||
- [NBD proxy for kernel mounts](../usage/nbd.en.md)
|
||||
- [CSI plugin for Kubernetes](../installation/kubernetes.en.md)
|
||||
- [OpenStack support: Cinder driver, Nova and libvirt patches](../installation/openstack.en.md)
|
||||
- [Proxmox storage plugin and packages](../installation/proxmox.en.md)
|
||||
- [Simplified NFS proxy for file-based image access emulation (suitable for VMWare)](../usage/nfs.en.md)
|
||||
|
||||
## Roadmap
|
||||
|
||||
The following features are planned for the future:
|
||||
|
||||
- Better OSD creation and auto-start tools
|
||||
- Other administrative tools
|
||||
- Web GUI
|
||||
- OpenNebula plugin
|
||||
- iSCSI proxy
|
||||
- Multi-threaded client
|
||||
- Faster failover
|
||||
- Scrubbing without checksums (verification of replicas)
|
||||
- Checksums
|
||||
- Tiered storage (SSD caching)
|
||||
- NVDIMM support
|
||||
- Compression (possibly)
|
||||
- Read caching using system page cache (possibly)
|
|
@ -1,62 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Введение → Возможности Vitastor
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](features.en.md)
|
||||
|
||||
# Возможности Vitastor
|
||||
|
||||
- [Серверные функции](#серверные-функции)
|
||||
- [Драйверы и инструменты](#драйверы-и-инструменты)
|
||||
- [Планы развития](#планы-развития)
|
||||
|
||||
## Серверные функции
|
||||
|
||||
- Базовая часть - надёжное кластерное блочное хранилище без единой точки отказа
|
||||
- [Производительность](../comparison1.ru.md) ;-D
|
||||
- [Несколько схем отказоустойчивости](../config/pool.ru.md#scheme): репликация, XOR n+1 (1 диск чётности), коды коррекции ошибок
|
||||
Рида-Соломона на основе библиотеки jerasure с любым числом дисков данных и чётности в группе
|
||||
- Конфигурация через простые человекочитаемые JSON-структуры в etcd
|
||||
- Автоматическое распределение данных по OSD, с поддержкой:
|
||||
- Математической оптимизации для лучшей равномерности распределения и минимизации перемещений данных
|
||||
- Нескольких пулов с разными схемами избыточности
|
||||
- Дерева распределения, выбора OSD по тегам / классам устройств (только SSD, только HDD) и по поддереву
|
||||
- Настраиваемых доменов отказа (диск/сервер/стойка и т.п.)
|
||||
- Восстановление деградированных блоков
|
||||
- Ребаланс, то есть перемещение данных между OSD (дисками)
|
||||
- [Поддержка "ленивого" fsync (fsync не на каждую операцию)](../config/layout-cluster.ru.md#immediate_commit)
|
||||
- Сбор статистики ввода/вывода в etcd
|
||||
- Статистика операций ввода/вывода и занятого места в разрезе инодов
|
||||
- Именование инодов через хранение их метаданных в etcd
|
||||
- Снапшоты и copy-on-write клоны
|
||||
- [Сглаживание производительности случайной записи в SSD+HDD конфигурациях](../config/osd.ru.md#throttle_small_writes)
|
||||
- [Поддержка RDMA/RoCEv2 через libibverbs](../config/network.ru.md#rdma_device)
|
||||
|
||||
## Драйверы и инструменты
|
||||
|
||||
- [Пакеты для Debian и CentOS](../installation/packages.ru.md)
|
||||
- [Консольный интерфейс управления образами (vitastor-cli)](../usage/cli.ru.md)
|
||||
- Общая пользовательская клиентская библиотека для работы с кластером
|
||||
- [Драйвер диска для QEMU](../usage/qemu.ru.md)
|
||||
- [Драйвер диска для утилиты тестирования производительности fio](../usage/fio.ru.md)
|
||||
- [NBD-прокси для монтирования образов ядром](../usage/nbd.ru.md) ("блочное устройство в режиме пользователя")
|
||||
- [CSI-плагин для Kubernetes](../installation/kubernetes.ru.md)
|
||||
- [Базовая поддержка OpenStack: драйвер Cinder, патчи для Nova и libvirt](../installation/openstack.ru.md)
|
||||
- [Плагин для Proxmox](../installation/proxmox.ru.md)
|
||||
- [Упрощённая NFS-прокси для эмуляции файлового доступа к образам (подходит для VMWare)](../usage/nfs.ru.md)
|
||||
|
||||
## Планы развития
|
||||
|
||||
- Более корректные скрипты разметки дисков и автоматического запуска OSD
|
||||
- Другие инструменты администрирования
|
||||
- Web-интерфейс
|
||||
- Плагин для OpenNebula
|
||||
- iSCSI-прокси
|
||||
- Многопоточный клиент
|
||||
- Более быстрое переключение при отказах
|
||||
- Фоновая проверка целостности без контрольных сумм (сверка реплик)
|
||||
- Контрольные суммы
|
||||
- Поддержка SSD-кэширования (tiered storage)
|
||||
- Поддержка NVDIMM
|
||||
- Возможно, сжатие
|
||||
- Возможно, поддержка кэширования данных через системный page cache
|
|
@ -1,95 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Introduction → Quick Start
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](quickstart.ru.md)
|
||||
|
||||
# Quick Start
|
||||
|
||||
- [Preparation](#preparation)
|
||||
- [Configure monitors](#configure-monitors)
|
||||
- [Configure OSDs](#configure-osds)
|
||||
- [Create a pool](#create-a-pool)
|
||||
- [Check cluster status](#check-cluster-status)
|
||||
- [Create an image](#create-an-image)
|
||||
- [Install plugins](#install-plugins)
|
||||
|
||||
## Preparation
|
||||
|
||||
- Get some SATA or NVMe SSDs with capacitors (server-grade drives). You can use desktop SSDs
|
||||
with lazy fsync, but prepare for inferior single-thread latency. Read more about capacitors
|
||||
[here](../config/layout-cluster.en.md#immediate_commit).
|
||||
- Get a fast network (at least 10 Gbit/s). Something like Mellanox ConnectX-4 with RoCEv2 is ideal.
|
||||
- Disable CPU powersaving: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||
- [Install Vitastor packages](../installation/packages.en.md).
|
||||
|
||||
## Configure monitors
|
||||
|
||||
On the monitor hosts:
|
||||
- Edit variables at the top of `/usr/lib/vitastor/mon/make-units.sh` to desired values.
|
||||
- Create systemd units for the monitor and etcd: `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Start etcd and monitors: `systemctl start etcd vitastor-mon`
|
||||
|
||||
## Configure OSDs
|
||||
|
||||
- Put etcd_address and osd_network into `/etc/vitastor/vitastor.conf`. Example:
|
||||
```
|
||||
{
|
||||
"etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"],
|
||||
"osd_network": "10.200.1.0/24"
|
||||
}
|
||||
```
|
||||
- Initialize OSDs:
|
||||
- Simplest, SSD-only: `/usr/lib/vitastor/mon/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`
|
||||
**Warning!** This very simple script by default makes units for server-grade SSDs with write-through cache!
|
||||
If it's not your case, you MUST remove disable_data_fsync and immediate_commit from systemd units.
|
||||
- Hybrid, HDD+SSD: `/usr/lib/vitastor/mon/make-osd-hybrid.js /dev/sda /dev/sdb ...` — pass all your
|
||||
devices (HDD and SSD) to this script — it will partition disks and initialize journals on its own.
|
||||
This script skips HDDs which are already partitioned so if you want to use non-empty disks for
|
||||
Vitastor you should first wipe them with `wipefs -a`. SSDs with GPT partition table are not skipped,
|
||||
but some free unpartitioned space must be available because the script creates new partitions for journals.
|
||||
- You can change OSD configuration in units or in `vitastor.conf`.
|
||||
Check [Configuration Reference](../config.en.md) for parameter descriptions.
|
||||
- If all your drives have capacitors, create global configuration in etcd: \
|
||||
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||
- Start all OSDs: `systemctl start vitastor.target`
|
||||
|
||||
## Create a pool
|
||||
|
||||
Create pool configuration in etcd:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool",
|
||||
"scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'
|
||||
```
|
||||
|
||||
For jerasure pools the configuration should look like the following:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=... put /vitastor/config/pools '{"2":{"name":"ecpool",
|
||||
"scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`
|
||||
```
|
||||
|
||||
After you do this, one of the monitors will configure PGs and OSDs will start them.
|
||||
|
||||
## Check cluster status
|
||||
|
||||
`vitastor-cli status`
|
||||
|
||||
Or you can check PG states with `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. All PGs should become 'active'.
|
||||
|
||||
## Create an image
|
||||
|
||||
Use vitastor-cli ([read CLI documentation here](../usage/cli.en.md)):
|
||||
|
||||
```
|
||||
vitastor-cli create -s 10G testimg
|
||||
```
|
||||
|
||||
After that, you can [run benchmarks](../usage/fio.en.md) or [start QEMU manually](../usage/qemu.en.md) with this image.
|
||||
|
||||
## Install plugins
|
||||
|
||||
- [Proxmox](../installation/proxmox.en.md)
|
||||
- [OpenStack](../installation/openstack.en.md)
|
||||
- [Kubernetes CSI](../installation/kubernetes.en.md)
|
|
@ -1,103 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Введение → Быстрый старт
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](quickstart.en.md)
|
||||
|
||||
# Быстрый старт
|
||||
|
||||
- [Подготовка](#подготовка)
|
||||
- [Настройте мониторы](#настройте-мониторы)
|
||||
- [Настройте OSD](#настройте-osd)
|
||||
- [Создайте пул](#создайте-пул)
|
||||
- [Проверьте состояние кластера](#проверьте-состояние-кластера)
|
||||
- [Создайте образ](#создайте-образ)
|
||||
- [Установите плагины](#установите-плагины)
|
||||
|
||||
## Подготовка
|
||||
|
||||
- Возьмите серверы с SSD (SATA или NVMe), желательно с конденсаторами (серверные SSD). Можно
|
||||
использовать и десктопные SSD, включив режим отложенного fsync, но производительность будет хуже.
|
||||
О конденсаторах читайте [здесь](../config/layout-cluster.ru.md#immediate_commit).
|
||||
- Возьмите быструю сеть, минимум 10 гбит/с. Идеал - что-то вроде Mellanox ConnectX-4 с RoCEv2.
|
||||
- Для лучшей производительности отключите энергосбережение CPU: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||
- [Установите пакеты Vitastor](../installation/packages.ru.md).
|
||||
|
||||
## Настройте мониторы
|
||||
|
||||
На хостах, выделенных под мониторы:
|
||||
- Пропишите нужные вам значения в файле `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Создайте юниты systemd для etcd и мониторов: `/usr/lib/vitastor/mon/make-units.sh`
|
||||
- Запустите etcd и мониторы: `systemctl start etcd vitastor-mon`
|
||||
- Пропишите etcd_address и osd_network в `/etc/vitastor/vitastor.conf`. Например:
|
||||
```
|
||||
{
|
||||
"etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"],
|
||||
"osd_network": "10.200.1.0/24"
|
||||
}
|
||||
```
|
||||
|
||||
## Настройте OSD
|
||||
|
||||
- Пропишите etcd_address и osd_network в `/etc/vitastor/vitastor.conf`. Например:
|
||||
```
|
||||
{
|
||||
"etcd_address": ["10.200.1.10:2379","10.200.1.11:2379","10.200.1.12:2379"],
|
||||
"osd_network": "10.200.1.0/24"
|
||||
}
|
||||
```
|
||||
- Инициализуйте OSD:
|
||||
- SSD: `/usr/lib/vitastor/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`. \
|
||||
**Внимание!** Скрипт по умолчанию рассчитан на то, что у вас диски с конденсаторами и отключённым
|
||||
кэшем! Если это не так, из юнитов systemd нужно убрать строчки disable_data_fsync и immediate_commit!
|
||||
- Гибридные, HDD+SSD: `/usr/lib/vitastor/mon/make-osd-hybrid.js /dev/sda /dev/sdb ...` - передайте
|
||||
все ваши SSD и HDD скрипту в командной строке подряд, скрипт автоматически выделит разделы под
|
||||
журналы на SSD и данные на HDD. Скрипт пропускает HDD, на которых уже есть разделы
|
||||
или вообще какие-то данные, поэтому если диски непустые, сначала очистите их с помощью
|
||||
`wipefs -a`. SSD с таблицей разделов не пропускаются, но так как скрипт создаёт новые разделы
|
||||
для журналов, на SSD должно быть доступно свободное нераспределённое место.
|
||||
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Описания параметров
|
||||
смотрите в [справке по конфигурации](../config.ru.md).
|
||||
- Если все ваши диски - серверные с конденсаторами, пропишите это в глобальную конфигурацию в etcd: \
|
||||
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||
- Запустите все OSD: `systemctl start vitastor.target`
|
||||
|
||||
## Создайте пул
|
||||
|
||||
Создайте конфигурацию пула с помощью etcdctl:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool",
|
||||
"scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'
|
||||
```
|
||||
|
||||
Для пулов с кодами коррекции ошибок конфигурация должна выглядеть примерно так:
|
||||
|
||||
```
|
||||
etcdctl --endpoints=... put /vitastor/config/pools '{"2":{"name":"ecpool",
|
||||
"scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`
|
||||
```
|
||||
|
||||
После этого один из мониторов должен сконфигурировать PG, а OSD должны запустить их.
|
||||
|
||||
## Проверьте состояние кластера
|
||||
|
||||
`vitastor-cli status`
|
||||
|
||||
Либо же вы можете проверять состояние PG прямо в etcd: `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. Все PG должны быть 'active'.
|
||||
|
||||
## Создайте образ
|
||||
|
||||
Используйте vitastor-cli ([смотрите документацию CLI здесь](../usage/cli.ru.md)):
|
||||
|
||||
```
|
||||
vitastor-cli create -s 10G testimg
|
||||
```
|
||||
|
||||
После этого вы можете [запускать тесты](../usage/fio.ru.md) или [вручную запускать QEMU](../usage/qemu.ru.md) с новым образом.
|
||||
|
||||
## Установите плагины
|
||||
|
||||
- [Proxmox](../installation/proxmox.ru.md)
|
||||
- [OpenStack](../installation/openstack.ru.md)
|
||||
- [Kubernetes CSI](../installation/kubernetes.ru.md)
|
|
@ -44,17 +44,16 @@
|
|||
- name: journal_size
|
||||
type: int
|
||||
info: |
|
||||
Journal size in bytes. By default, all available space between journal_offset
|
||||
and data_offset, meta_offset or the end of the journal device is used.
|
||||
Large journals aren't needed in SSD-only setups, 32 MB is always enough.
|
||||
In SSD+HDD setups it is beneficial to use larger journals (for example, 1 GB)
|
||||
and enable [throttle_small_writes](osd.en.md#throttle_small_writes).
|
||||
Journal size in bytes. Doesn't have to be large, 16-32 MB is usually fine.
|
||||
By default, the whole journal device will be used for the journal. You must
|
||||
set it to some value manually (or use make-osd.sh) if you colocate the
|
||||
journal with data or metadata.
|
||||
info_ru: |
|
||||
Размер журнала в байтах. По умолчанию для журнала используется всё доступное
|
||||
место между journal_offset и data_offset, meta_offset или концом диска.
|
||||
В SSD-кластерах большие журналы не нужны, достаточно 32 МБ. В гибридных
|
||||
(SSD+HDD) кластерах осмысленно использовать больший размер журнал (например, 1 ГБ)
|
||||
и включить [throttle_small_writes](osd.ru.md#throttle_small_writes).
|
||||
Размер журнала в байтах. Большим быть не обязан, 16-32 МБ обычно достаточно.
|
||||
По умолчанию для журнала используется всё устройство журнала. Если же вы
|
||||
размещаете журнал на устройстве данных или метаданных, то вы должны
|
||||
установить эту опцию в какое-то значение сами (или использовать скрипт
|
||||
make-osd.sh).
|
||||
- name: meta_offset
|
||||
type: int
|
||||
default: 0
|
|
@ -35,15 +35,15 @@
|
|||
default: true
|
||||
info: |
|
||||
Try to use RDMA for communication if it's available. Disable if you don't
|
||||
want Vitastor to use RDMA. TCP-only clients can also talk to an RDMA-enabled
|
||||
cluster, so disabling RDMA may be needed if clients have RDMA devices,
|
||||
but they are not connected to the cluster.
|
||||
want Vitastor to use RDMA. RDMA increases the performance, but TCP-only
|
||||
clients can still talk to an RDMA-enabled cluster, so you don't need to
|
||||
make sure that all clients support RDMA when enabling it.
|
||||
info_ru: |
|
||||
Пытаться использовать RDMA для связи при наличии доступных устройств.
|
||||
Отключите, если вы не хотите, чтобы Vitastor использовал RDMA.
|
||||
TCP-клиенты также могут работать с RDMA-кластером, так что отключать
|
||||
RDMA может быть нужно только если у клиентов есть RDMA-устройства,
|
||||
но они не имеют соединения с кластером Vitastor.
|
||||
RDMA улучшает производительность, но
|
||||
Клиенты и клиентов and TCP-only clients in the cluster at the
|
||||
same time - TCP-only clients are still able to use an RDMA-enabled cluster.
|
||||
- name: rdma_device
|
||||
type: string
|
||||
info: |
|
|
@ -248,8 +248,6 @@
|
|||
row and slow down significantly (from 25000+ iops to ~3000 iops). When
|
||||
this option is set, Vitastor will always move to the next sector of the
|
||||
journal after writing it instead of possibly overwriting it the second time.
|
||||
|
||||
Most (99%) other SSDs don't need this option.
|
||||
info_ru: |
|
||||
Включайте данную опцию для SSD вроде Intel D3-S4510 и D3-S4610, которые
|
||||
ОЧЕНЬ не любят, когда ПО перезаписывает один и тот же сектор несколько раз
|
||||
|
@ -258,8 +256,6 @@
|
|||
данная опция установлена, Vitastor всегда переходит к следующему сектору
|
||||
журнала после записи вместо потенциально повторной перезаписи того же
|
||||
самого сектора.
|
||||
|
||||
Почти все другие SSD (99% моделей) не требуют данной опции.
|
||||
- name: throttle_small_writes
|
||||
type: bool
|
||||
default: false
|
|
@ -1,108 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Performance → Example Comparison with Ceph
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](comparison1.ru.md)
|
||||
|
||||
# Example Comparison with Ceph
|
||||
|
||||
- [Test environment](#test-environment)
|
||||
- [Raw drive performance](#raw-drive-performance)
|
||||
- [2 replicas](#2-replicas)
|
||||
- [Ceph 15.2.4 (Bluestore)](#ceph-15-2-4-bluestore)
|
||||
- [Vitastor 0.4.0 (native)](#vitastor-0-4-0-native)
|
||||
- [Vitastor 0.4.0 (NBD)](#vitastor-0-4-0-nbd)
|
||||
- [EC/XOR 2+1](#ec/xor-2-1)
|
||||
- [Ceph 15.2.4](#ceph-15-2-4)
|
||||
- [Vitastor 0.4.0](#vitastor-0-4-0)
|
||||
|
||||
## Test environment
|
||||
|
||||
Hardware configuration: 4 nodes, each with:
|
||||
- 6x SATA SSD Intel D3-S4510 3.84 TB
|
||||
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
|
||||
- 384 GB RAM
|
||||
- 1x 25 GbE network interface (Mellanox ConnectX-4 LX), connected to a Juniper QFX5200 switch
|
||||
|
||||
CPU powersaving was disabled. Both Vitastor and Ceph were configured with 2 OSDs per 1 SSD.
|
||||
|
||||
All of the results below apply to 4 KB blocks and random access (unless indicated otherwise).
|
||||
|
||||
T8Q64 tests were conducted over 8 400GB RBD images from all hosts (every host was running 2 instances of fio).
|
||||
This is because Ceph has performance penalties related to running multiple clients over a single RBD image.
|
||||
|
||||
cephx_sign_messages was set to false during tests, RocksDB and Bluestore settings were left at defaults.
|
||||
|
||||
T8Q64 read test was conducted over 1 larger inode (3.2T) from all hosts (every host was running 2 instances of fio).
|
||||
Vitastor has no performance penalties related to running multiple clients over a single inode.
|
||||
If conducted from one node with all primary OSDs moved to other nodes the result was slightly lower (689000 iops),
|
||||
this is because all operations resulted in network roundtrips between the client and the primary OSD.
|
||||
When fio was colocated with OSDs (like in Ceph benchmarks above), 1/4 of the read workload actually
|
||||
used the loopback network.
|
||||
|
||||
Vitastor was configured with: `--disable_data_fsync true --immediate_commit all --flusher_count 8
|
||||
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
|
||||
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
|
||||
--journal_size 16777216`.
|
||||
|
||||
## Raw drive performance
|
||||
|
||||
- T1Q1 write ~27000 iops (~0.037ms latency)
|
||||
- T1Q1 read ~9800 iops (~0.101ms latency)
|
||||
- T1Q32 write ~60000 iops
|
||||
- T1Q32 read ~81700 iops
|
||||
|
||||
## 2 replicas
|
||||
|
||||
### Ceph 15.2.4 (Bluestore)
|
||||
|
||||
- T1Q1 write ~1000 iops (~1ms latency)
|
||||
- T1Q1 read ~1750 iops (~0.57ms latency)
|
||||
- T8Q64 write ~100000 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
- T8Q64 read ~480000 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
|
||||
In fact, not that bad for Ceph. These servers are an example of well-balanced Ceph nodes.
|
||||
However, CPU usage and I/O latency were through the roof, as usual.
|
||||
|
||||
### Vitastor 0.4.0 (native)
|
||||
|
||||
- T1Q1 write: 7087 iops (0.14ms latency)
|
||||
- T1Q1 read: 6838 iops (0.145ms latency)
|
||||
- T2Q64 write: 162000 iops, total CPU usage by OSDs about 3 virtual cores on each node
|
||||
- T8Q64 read: 895000 iops, total CPU usage by OSDs about 4 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 2800 MB/s
|
||||
- Linear read (4M T1Q32): 1500 MB/s
|
||||
|
||||
### Vitastor 0.4.0 (NBD)
|
||||
|
||||
NBD is currently required to mount Vitastor via kernel, but it imposes additional overhead
|
||||
due to additional copying between the kernel and userspace. This mostly hurts linear
|
||||
bandwidth, not iops.
|
||||
|
||||
Vitastor with single-threaded NBD on the same hardware:
|
||||
- T1Q1 write: 6000 iops (0.166ms latency)
|
||||
- T1Q1 read: 5518 iops (0.18ms latency)
|
||||
- T1Q128 write: 94400 iops
|
||||
- T1Q128 read: 103000 iops
|
||||
- Linear write (4M T1Q128): 1266 MB/s (compared to 2800 MB/s via fio)
|
||||
- Linear read (4M T1Q128): 975 MB/s (compared to 1500 MB/s via fio)
|
||||
|
||||
## EC/XOR 2+1
|
||||
|
||||
### Ceph 15.2.4
|
||||
|
||||
- T1Q1 write: 730 iops (~1.37ms latency)
|
||||
- T1Q1 read: 1500 iops with cold cache (~0.66ms latency), 2300 iops after 2 minute metadata cache warmup (~0.435ms latency)
|
||||
- T4Q128 write (4 RBD images): 45300 iops, total CPU usage by OSDs about 30 virtual cores on each node
|
||||
- T8Q64 read (4 RBD images): 278600 iops, total CPU usage by OSDs about 40 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 1950 MB/s before preallocation, 2500 MB/s after preallocation
|
||||
- Linear read (4M T1Q32): 2400 MB/s
|
||||
|
||||
### Vitastor 0.4.0
|
||||
|
||||
- T1Q1 write: 2808 iops (~0.355ms latency)
|
||||
- T1Q1 read: 6190 iops (~0.16ms latency)
|
||||
- T2Q64 write: 85500 iops, total CPU usage by OSDs about 3.4 virtual cores on each node
|
||||
- T8Q64 read: 812000 iops, total CPU usage by OSDs about 4.7 virtual cores on each node
|
||||
- Linear write (4M T1Q32): 3200 MB/s
|
||||
- Linear read (4M T1Q32): 1800 MB/s
|
|
@ -1,113 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Производительность → Пример сравнения с Ceph
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](comparison1.en.md)
|
||||
|
||||
# Пример сравнения с Ceph
|
||||
|
||||
- [Описание стенда](#описание-стенда)
|
||||
- [Производительность голых дисков](#производительность-голых-дисков)
|
||||
- [2 реплики](#2-реплики)
|
||||
- [Ceph 15.2.4 (Bluestore)](#ceph-15-2-4-bluestore)
|
||||
- [Vitastor 0.4.0 (нативный драйвер fio)](#vitastor-0-4-0-нативный-драйвер-fio)
|
||||
- [Vitastor 0.4.0 (NBD)](#vitastor-0-4-0-nbd)
|
||||
- [EC/XOR 2+1](#ec/xor-2-1)
|
||||
- [Ceph 15.2.4](#ceph-15-2-4)
|
||||
- [Vitastor 0.4.0](#vitastor-0-4-0)
|
||||
|
||||
## Описание стенда
|
||||
|
||||
Железо: 4 сервера, в каждом:
|
||||
- 6x SATA SSD Intel D3-4510 3.84 TB
|
||||
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
|
||||
- 384 GB RAM
|
||||
- 1x 25 GbE сетевая карта (Mellanox ConnectX-4 LX), подключённая к свитчу Juniper QFX5200
|
||||
|
||||
Экономия энергии CPU отключена. В тестах и Vitastor, и Ceph развёрнуто по 2 OSD на 1 SSD.
|
||||
|
||||
Все результаты ниже относятся к случайной нагрузке 4 КБ блоками (если явно не указано обратное).
|
||||
|
||||
Тесты в 8 потоков проводились на 8 400GB RBD образах со всех хостов (с каждого хоста запускалось 2 процесса fio).
|
||||
Это нужно потому, что в Ceph несколько RBD-клиентов, пишущих в 1 образ, очень сильно замедляются.
|
||||
|
||||
Настройки RocksDB и Bluestore в Ceph не менялись, единственным изменением было отключение cephx_sign_messages.
|
||||
|
||||
Тест на чтение в 8 потоков проводился на 1 большом образе (3.2 ТБ) со всех хостов (опять же, по 2 fio с каждого).
|
||||
В Vitastor никакой разницы между 1 образом и 8-ю нет. Естественно, примерно 1/4 запросов чтения
|
||||
в такой конфигурации, как и в тестах Ceph выше, обслуживалась с локальной машины. Если проводить
|
||||
тест так, чтобы все операции всегда обращались к первичным OSD по сети - тест сильнее упирался
|
||||
в сеть и результат составлял примерно 689000 iops.
|
||||
|
||||
Настройки Vitastor: `--disable_data_fsync true --immediate_commit all --flusher_count 8
|
||||
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
|
||||
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
|
||||
--journal_size 16777216`.
|
||||
|
||||
## Производительность голых дисков
|
||||
|
||||
- T1Q1 запись ~27000 iops (задержка ~0.037ms)
|
||||
- T1Q1 чтение ~9800 iops (задержка ~0.101ms)
|
||||
- T1Q32 запись ~60000 iops
|
||||
- T1Q32 чтение ~81700 iops
|
||||
|
||||
## 2 реплики
|
||||
|
||||
### Ceph 15.2.4 (Bluestore)
|
||||
|
||||
- T1Q1 запись ~1000 iops (задержка ~1ms)
|
||||
- T1Q1 чтение ~1750 iops (задержка ~0.57ms)
|
||||
- T8Q64 запись ~100000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
|
||||
- T8Q64 чтение ~480000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
|
||||
|
||||
Если не учитывать как обычно запредельное потребление CPU (40 ядер), не так уж и плохо для Ceph.
|
||||
Данные серверы - как раз хороший пример сбалансированных Ceph-нод - 6 SATA SSD как раз
|
||||
утилизируют 25-гигабитную сеть, а без 2 мощных процессоров Ceph-у бы не хватило ядер,
|
||||
чтобы выдать пристойный результат.
|
||||
|
||||
### Vitastor 0.4.0 (нативный драйвер fio)
|
||||
|
||||
- T1Q1 запись: 7087 iops (задержка 0.14ms)
|
||||
- T1Q1 чтение: 6838 iops (задержка 0.145ms)
|
||||
- T2Q64 запись: 162000 iops, потребление CPU - 3 ядра на каждом сервере
|
||||
- T8Q64 чтение: 895000 iops, потребление CPU - 4 ядра на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 2800 МБ/с
|
||||
- Линейное чтение (4M T1Q32): 1500 МБ/с
|
||||
|
||||
### Vitastor 0.4.0 (NBD)
|
||||
|
||||
NBD расшифровывается как "сетевое блочное устройство", но на самом деле оно также
|
||||
работает просто как аналог FUSE для блочных устройств, то есть, представляет собой
|
||||
"блочное устройство в пространстве пользователя".
|
||||
|
||||
NBD - на данный момент единственный способ монтировать Vitastor ядром Linux. Его
|
||||
производительность немного хуже из-за дополнительных операций копирований данных
|
||||
между ядром и пространством пользователя, что, правда, в основном затрагивает линейное
|
||||
чтение/запись, а не случайный доступ.
|
||||
|
||||
- T1Q1 запись: 6000 iops (задержка 0.166ms)
|
||||
- T1Q1 чтение: 5518 iops (задержка 0.18ms)
|
||||
- T1Q128 запись: 94400 iops
|
||||
- T1Q128 чтение: 103000 iops
|
||||
- Линейная запись (4M T1Q128): 1266 МБ/с (в сравнении с 2800 МБ/с через fio)
|
||||
- Линейное чтение (4M T1Q128): 975 МБ/с (в сравнении с 1500 МБ/с через fio)
|
||||
|
||||
## EC/XOR 2+1
|
||||
|
||||
### Ceph 15.2.4
|
||||
|
||||
- T1Q1 запись: 730 iops (задержка ~1.37ms latency)
|
||||
- T1Q1 чтение: 1500 iops с холодным кэшем метаданных (задержка ~0.66ms), 2300 iops через 2 минуты прогрева (задержка ~0.435ms)
|
||||
- T4Q128 запись (4 RBD images): 45300 iops, потребление CPU - 30 ядер на каждом сервере
|
||||
- T8Q64 чтение (4 RBD images): 278600 iops, потребление CPU - 40 ядер на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 1950 МБ/с в пустой образ, 2500 МБ/с в заполненный образ
|
||||
- Линейное чтение (4M T1Q32): 2400 МБ/с
|
||||
|
||||
### Vitastor 0.4.0
|
||||
|
||||
- T1Q1 запись: 2808 iops (задержка ~0.355ms)
|
||||
- T1Q1 чтение: 6190 iops (задержка ~0.16ms)
|
||||
- T2Q64 запись: 85500 iops, потребление CPU - 3.4 ядра на каждом сервере
|
||||
- T8Q64 чтение: 812000 iops, потребление CPU - 4.7 ядра на каждом сервере
|
||||
- Линейная запись (4M T1Q32): 3200 МБ/с
|
||||
- Линейное чтение (4M T1Q32): 1800 МБ/с
|
|
@ -1,49 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Performance → Vitastor's Theoretical Maximum Performance
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](theoretical.ru.md)
|
||||
|
||||
# Vitastor's Theoretical Maximum Performance
|
||||
|
||||
Replicated setups:
|
||||
- Single-threaded (T1Q1) read latency: 1 network roundtrip + 1 disk read.
|
||||
- Single-threaded write+fsync latency:
|
||||
- With immediate commit: 2 network roundtrips + 1 disk write.
|
||||
- With lazy commit: 4 network roundtrips + 1 disk write + 1 disk flush.
|
||||
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
||||
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops / number of replicas / write amplification)).
|
||||
|
||||
EC/XOR setups:
|
||||
- Single-threaded (T1Q1) read latency: 1.5 network roundtrips + 1 disk read.
|
||||
- Single-threaded write+fsync latency:
|
||||
- With immediate commit: 3.5 network roundtrips + 1 disk read + 2 disk writes.
|
||||
- With lazy commit: 5.5 network roundtrips + 1 disk read + 2 disk writes + 2 disk fsyncs.
|
||||
- 0.5 in actually (k-1)/k which means that an additional roundtrip doesn't happen when
|
||||
the read sub-operation can be served locally.
|
||||
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
||||
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops * number of data drives / (number of data + parity drives) / write amplification)).
|
||||
In fact, you should put disk write iops under the condition of ~10% reads / ~90% writes in this formula.
|
||||
|
||||
Write amplification for 4 KB blocks is usually 3-5 in Vitastor:
|
||||
1. Journal block write
|
||||
2. Journal data write
|
||||
3. Metadata block write
|
||||
4. Another journal block write for EC/XOR setups
|
||||
5. Data block write
|
||||
|
||||
If you manage to get an SSD which handles 512 byte blocks well (Optane?) you may
|
||||
lower 1, 3 and 4 to 512 bytes (1/8 of data size) and get WA as low as 2.375.
|
||||
|
||||
Lazy fsync also reduces WA for parallel workloads because journal blocks are only
|
||||
written when they fill up or fsync is requested.
|
||||
|
||||
## In Practice
|
||||
|
||||
In practice, using tests from [Understanding Performance](understanding.en.md)
|
||||
and good server-grade SSD/NVMe drives, you should head for:
|
||||
- At least 5000 T1Q1 replicated read and write iops (maximum 0.2ms latency)
|
||||
- At least ~80k parallel read iops or ~30k write iops per 1 core (1 OSD)
|
||||
- Disk-speed or wire-speed linear reads and writes, whichever is the bottleneck in your case
|
||||
|
||||
Lower results may mean that you have bad drives, bad network or some kind of misconfiguration.
|
|
@ -1,41 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Производительность → Теоретическая максимальная производительность Vitastor
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](theoretical.en.md)
|
||||
|
||||
# Теоретическая максимальная производительность Vitastor
|
||||
|
||||
При использовании репликации:
|
||||
- Задержка чтения в 1 поток (T1Q1): 1 сетевой RTT + 1 чтение с диска.
|
||||
- Запись+fsync в 1 поток:
|
||||
- С мгновенным сбросом: 2 RTT + 1 запись.
|
||||
- С отложенным ("ленивым") сбросом: 4 RTT + 1 запись + 1 fsync.
|
||||
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
|
||||
- Параллельная запись: сумма IOPS всех дисков / число реплик / WA либо производительность сети, если в сеть упрётся раньше.
|
||||
|
||||
При использовании кодов коррекции ошибок (EC):
|
||||
- Задержка чтения в 1 поток (T1Q1): 1.5 RTT + 1 чтение.
|
||||
- Запись+fsync в 1 поток:
|
||||
- С мгновенным сбросом: 3.5 RTT + 1 чтение + 2 записи.
|
||||
- С отложенным ("ленивым") сбросом: 5.5 RTT + 1 чтение + 2 записи + 2 fsync.
|
||||
- Под 0.5 на самом деле подразумевается (k-1)/k, где k - число дисков данных,
|
||||
что означает, что дополнительное обращение по сети не нужно, когда операция
|
||||
чтения обслуживается локально.
|
||||
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
|
||||
- Параллельная запись: сумма IOPS всех дисков / общее число дисков данных и чётности / WA либо производительность сети, если в сеть упрётся раньше.
|
||||
Примечание: IOPS дисков в данном случае надо брать в смешанном режиме чтения/записи в пропорции, аналогичной формулам выше.
|
||||
|
||||
WA (мультипликатор записи) для 4 КБ блоков в Vitastor обычно составляет 3-5:
|
||||
1. Запись метаданных в журнал
|
||||
2. Запись блока данных в журнал
|
||||
3. Запись метаданных в БД
|
||||
4. Ещё одна запись метаданных в журнал при использовании EC
|
||||
5. Запись блока данных на диск данных
|
||||
|
||||
Если вы найдёте SSD, хорошо работающий с 512-байтными блоками данных (Optane?),
|
||||
то 1, 3 и 4 можно снизить до 512 байт (1/8 от размера данных) и получить WA всего 2.375.
|
||||
|
||||
Кроме того, WA снижается при использовании отложенного/ленивого сброса при параллельной
|
||||
нагрузке, т.к. блоки журнала записываются на диск только когда они заполняются или явным
|
||||
образом запрашивается fsync.
|
|
@ -1,57 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Performance → Understanding Storage Performance
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](understanding.ru.md)
|
||||
|
||||
# Understanding Storage Performance
|
||||
|
||||
The most important thing for fast storage is latency, not parallel iops.
|
||||
|
||||
The best possible latency is achieved with one thread and queue depth of 1 which basically means
|
||||
"client load as low as possible". In this case IOPS = 1/latency, and this number doesn't
|
||||
scale with number of servers, drives, server processes or threads and so on.
|
||||
Single-threaded IOPS and latency numbers only depend on *how fast a single daemon is*.
|
||||
|
||||
Why is it important? It's important because some of the applications *can't* use
|
||||
queue depth greater than 1 because their task isn't parallelizable. A notable example
|
||||
is any ACID DBMS because all of them write their WALs sequentially with fsync()s.
|
||||
|
||||
fsync, by the way, is another important thing often missing in benchmarks. The point is
|
||||
that drives have cache buffers and don't guarantee that your data is actually persisted
|
||||
until you call fsync() which is translated to a FLUSH CACHE command by the OS.
|
||||
|
||||
Desktop SSDs are very fast without fsync - NVMes, for example, can process ~80000 write
|
||||
operations per second with queue depth of 1 without fsync - but they're really slow with
|
||||
fsync because they have to actually write data to flash chips when you call fsync. Typical
|
||||
number is around 1000-2000 iops with fsync.
|
||||
|
||||
Server SSDs often have supercapacitors that act as a built-in UPS and allow the drive
|
||||
to flush its DRAM cache to the persistent flash storage when a power loss occurs.
|
||||
This makes them perform equally well with and without fsync. This feature is called
|
||||
"Advanced Power Loss Protection" by Intel; other vendors either call it similarly
|
||||
or directly as "Full Capacitor-Based Power Loss Protection".
|
||||
|
||||
All software-defined storages that I currently know are slow in terms of latency.
|
||||
Notable examples are Ceph and internal SDSes used by cloud providers like Amazon, Google,
|
||||
Yandex and so on. They're all slow and can only reach ~0.3ms read and ~0.6ms 4 KB write latency
|
||||
with best-in-slot hardware.
|
||||
|
||||
And that's in the SSD era when you can buy an SSD that has ~0.04ms latency for 100 $.
|
||||
|
||||
## fio commands
|
||||
|
||||
I use the following 6 commands with small variations to benchmark block storage:
|
||||
|
||||
- Linear write (results in MB/s):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
|
||||
- Linear read (results in MB/s):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
|
||||
- Random write latency (T1Q1, this hurts storages the most) (results in iops or milliseconds of latency):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Random read latency (T1Q1) (results in iops or milliseconds of latency):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
- Parallel write iops (use numjobs=4 if a single CPU core is insufficient to saturate the load) (results only in iops):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Parallel read iops (use numjobs if a single CPU core is insufficient to saturate the load) (results only in iops):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
|
|
@ -1,65 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Производительность → Понимание сути производительности систем хранения
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](understanding.en.md)
|
||||
|
||||
# Понимание сути производительности систем хранения
|
||||
|
||||
Вкратце: для быстрой хранилки задержки важнее, чем пиковые iops-ы.
|
||||
|
||||
Лучшая возможная задержка достигается при тестировании в 1 поток с глубиной очереди 1,
|
||||
что приблизительно означает минимально нагруженное состояние кластера. В данном случае
|
||||
IOPS = 1/задержка. Ни числом серверов, ни дисков, ни серверных процессов/потоков
|
||||
задержка не масштабируется... Она зависит только от того, насколько быстро один
|
||||
серверный процесс (и клиент) обрабатывают одну операцию.
|
||||
|
||||
Почему задержки важны? Потому, что некоторые приложения *не могут* использовать глубину
|
||||
очереди больше 1, ибо их задача не параллелизуется. Важный пример - это все СУБД
|
||||
с поддержкой консистентности (ACID), потому что все они обеспечивают её через
|
||||
журналирование, а журналы пишутся последовательно и с fsync() после каждой операции.
|
||||
|
||||
fsync, кстати - это ещё одна очень важная вещь, про которую почти всегда забывают в тестах.
|
||||
Смысл в том, что все современные диски имеют кэши/буферы записи и не гарантируют, что
|
||||
данные реально физически записываются на носитель до того, как вы делаете fsync(),
|
||||
который транслируется в команду сброса кэша операционной системой.
|
||||
|
||||
Дешёвые SSD для настольных ПК и ноутбуков очень быстрые без fsync - NVMe диски, например,
|
||||
могут обработать порядка 80000 операций записи в секунду с глубиной очереди 1 без fsync.
|
||||
Однако с fsync, когда они реально вынуждены писать каждый блок данных во флеш-память,
|
||||
они выжимают лишь 1000-2000 операций записи в секунду (число практически постоянное
|
||||
для всех моделей SSD).
|
||||
|
||||
Серверные SSD часто имеют суперконденсаторы, работающие как встроенный источник
|
||||
бесперебойного питания и дающие дискам успеть сбросить их DRAM-кэш в постоянную
|
||||
флеш-память при отключении питания. Благодаря этому диски с чистой совестью
|
||||
*игнорируют fsync*, так как точно знают, что данные из кэша доедут до постоянной
|
||||
памяти.
|
||||
|
||||
Все наиболее известные программные СХД, например, Ceph и внутренние СХД, используемые
|
||||
такими облачными провайдерами, как Amazon, Google, Яндекс, медленные в смысле задержки.
|
||||
В лучшем случае они дают задержки от 0.3мс на чтение и 0.6мс на запись 4 КБ блоками
|
||||
даже при условии использования наилучшего возможного железа.
|
||||
|
||||
И это в эпоху SSD, когда вы можете пойти на рынок и купить там SSD, задержка которого
|
||||
на чтение будет 0.1мс, а на запись - 0.04мс, за 100$ или даже дешевле.
|
||||
|
||||
## Команды fio
|
||||
|
||||
Когда мне нужно быстро протестировать производительность блочного устройства, я
|
||||
использую следующие 6 команд, с небольшими вариациями:
|
||||
|
||||
- Линейная запись (результаты в МБ/с):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
|
||||
- Линейное чтение (результаты в МБ/с):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
|
||||
- Запись в 1 поток (T1Q1) (результаты в iops или миллисекундах задержки):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Чтение в 1 поток (T1Q1) (результаты в iops или миллисекундах задержки):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
- Параллельная запись (numjobs=4 использовать, когда 1 ядро CPU не может насытить диск) (результаты только в iops):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
|
||||
- Параллельное чтение (numjobs - аналогично) (результаты только в iops):
|
||||
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
|
||||
|
||||
Почему нужно тестировать именно так - см. [тут](https://yourcmc.ru/wiki/Производительность_Ceph#.D0.9B.D0.B8.D1.80.D0.B8.D1.87.D0.B5.D1.81.D0.BA.D0.BE.D0.B5_.D0.BE.D1.82.D1.81.D1.82.D1.83.D0.BF.D0.BB.D0.B5.D0.BD.D0.B8.D0.B5).
|
|
@ -1,206 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Usage → Vitastor CLI
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](cli.ru.md)
|
||||
|
||||
# Vitastor CLI
|
||||
|
||||
vitastor-cli is a command-line tool for administrative tasks like image management.
|
||||
|
||||
It supports the following commands:
|
||||
|
||||
- [status](#status)
|
||||
- [df](#df)
|
||||
- [ls](#ls)
|
||||
- [create](#create)
|
||||
- [modify](#modify)
|
||||
- [rm](#rm)
|
||||
- [flatten](#flatten)
|
||||
- [rm-data](#rm-data)
|
||||
- [merge-data](#merge-data)
|
||||
- [alloc-osd](#alloc-osd)
|
||||
- [simple-offsets](#simple-offsets)
|
||||
|
||||
Global options:
|
||||
|
||||
```
|
||||
--etcd_address ADDR Etcd connection address
|
||||
--iodepth N Send N operations in parallel to each OSD when possible (default 32)
|
||||
--parallel_osds M Work with M osds in parallel when possible (default 4)
|
||||
--progress 1|0 Report progress (default 1)
|
||||
--cas 1|0 Use CAS writes for flatten, merge, rm (default is decide automatically)
|
||||
--no-color Disable colored output
|
||||
--json JSON output
|
||||
```
|
||||
|
||||
## status
|
||||
|
||||
`vitastor-cli status`
|
||||
|
||||
Показать состояние кластера.
|
||||
|
||||
Пример вывода:
|
||||
|
||||
```
|
||||
cluster:
|
||||
etcd: 1 / 1 up, 1.8 M database size
|
||||
mon: 1 up, master stump
|
||||
osd: 8 / 12 up
|
||||
|
||||
data:
|
||||
raw: 498.5 G used, 301.2 G / 799.7 G available, 399.8 G down
|
||||
state: 156.6 G clean, 97.6 G misplaced
|
||||
pools: 2 / 3 active
|
||||
pgs: 30 active
|
||||
34 active+has_misplaced
|
||||
32 offline
|
||||
|
||||
io:
|
||||
client: 0 B/s rd, 0 op/s rd, 0 B/s wr, 0 op/s wr
|
||||
rebalance: 989.8 M/s, 7.9 K op/s
|
||||
```
|
||||
|
||||
## df
|
||||
|
||||
`vitastor-cli df`
|
||||
|
||||
Показать список пулов и занятое место.
|
||||
|
||||
Пример вывода:
|
||||
|
||||
```
|
||||
NAME SCHEME PGS TOTAL USED AVAILABLE USED% EFFICIENCY
|
||||
testpool 2/1 32 100 G 34.2 G 60.7 G 39.23% 100%
|
||||
size1 1/1 32 199.9 G 10 G 121.5 G 39.23% 100%
|
||||
kaveri 2/1 32 0 B 10 G 0 B 100% 0%
|
||||
```
|
||||
|
||||
В примере у пула "kaveri" эффективность равна нулю, так как все OSD выключены.
|
||||
|
||||
## ls
|
||||
|
||||
`vitastor-cli ls [-l] [-p POOL] [--sort FIELD] [-r] [-n N] [<glob> ...]`
|
||||
|
||||
Показать список образов, если переданы шаблоны `<glob>`, то только с именами,
|
||||
соответствующими этим шаблонам (стандартные ФС-шаблоны с * и ?).
|
||||
|
||||
Опции:
|
||||
|
||||
```
|
||||
-p|--pool POOL Фильтровать образы по пулу (ID или имени)
|
||||
-l|--long Также выводить статистику занятого места и ввода-вывода
|
||||
--del Также выводить статистику операций удаления
|
||||
--sort FIELD Сортировать по заданному полю (name, size, used_size, <read|write|delete>_<iops|bps|lat|queue>)
|
||||
-r|--reverse Сортировать в обратном порядке
|
||||
-n|--count N Показывать только первые N записей
|
||||
```
|
||||
|
||||
Пример вывода:
|
||||
|
||||
```
|
||||
NAME POOL SIZE USED READ IOPS QUEUE LAT WRITE IOPS QUEUE LAT FLAGS PARENT
|
||||
debian9 testpool 20 G 12.3 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us RO
|
||||
pve/vm-100-disk-0 testpool 20 G 0 B 0 B/s 0 0 0 us 0 B/s 0 0 0 us - debian9
|
||||
pve/base-101-disk-0 testpool 20 G 0 B 0 B/s 0 0 0 us 0 B/s 0 0 0 us RO debian9
|
||||
pve/vm-102-disk-0 testpool 32 G 36.4 M 0 B/s 0 0 0 us 0 B/s 0 0 0 us - pve/base-101-disk-0
|
||||
debian9-test testpool 20 G 36.6 M 0 B/s 0 0 0 us 0 B/s 0 0 0 us - debian9
|
||||
bench testpool 10 G 10 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us -
|
||||
bench-kaveri kaveri 10 G 10 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us -
|
||||
```
|
||||
|
||||
## create
|
||||
|
||||
`vitastor-cli create -s|--size <size> [-p|--pool <id|name>] [--parent <parent_name>[@<snapshot>]] <name>`
|
||||
|
||||
Создать образ. Для размера `<size>` можно использовать суффиксы K/M/G/T (килобайт-мегабайт-гигабайт-терабайт).
|
||||
Если указана опция `--parent`, создаётся клон образа. Родитель `<parent_name>[@<snapshot>]` должен быть
|
||||
снимком (или просто немодифицируемым образом). Пул обязательно указывать, если в кластере больше одного пула.
|
||||
|
||||
```
|
||||
vitastor-cli create --snapshot <snapshot> [-p|--pool <id|name>] <image>
|
||||
vitastor-cli snap-create [-p|--pool <id|name>] <image>@<snapshot>
|
||||
```
|
||||
|
||||
Создать снимок образа `<name>` (можно использовать любую форму команды). Снимок можно создавать без остановки
|
||||
клиентов, если пишущий клиент максимум 1.
|
||||
|
||||
## modify
|
||||
|
||||
`vitastor-cli modify <name> [--rename <new-name>] [--resize <size>] [--readonly | --readwrite] [-f|--force]`
|
||||
|
||||
Изменить размер, имя образа или флаг "только для чтения". Снимать флаг "только для чтения"
|
||||
и уменьшать размер образов, у которых есть дочерние клоны, без `--force` нельзя.
|
||||
|
||||
Если новый размер меньше старого, "лишние" данные будут удалены, поэтому перед уменьшением
|
||||
образа сначала уменьшите файловую систему в нём.
|
||||
|
||||
```
|
||||
-f|--force Разрешить уменьшение или перевод в чтение-запись образа, у которого есть клоны.
|
||||
```
|
||||
|
||||
## rm
|
||||
|
||||
`vitastor-cli rm <from> [<to>] [--writers-stopped]`
|
||||
|
||||
Удалить образ `<from>` или все слои от `<from>` до `<to>` (`<to>` должен быть дочерним
|
||||
образом `<from>`), одновременно меняя родительские образы их клонов (если таковые есть).
|
||||
|
||||
`--writers-stopped` позволяет чуть более эффективно удалять образы в частом случае, когда
|
||||
у удаляемой цепочки есть только один дочерний образ, содержащий небольшой объём данных.
|
||||
В этом случае дочерний образ вливается в родительский и удаляется, а родительский
|
||||
переименовывается в дочерний.
|
||||
|
||||
В других случаях родительские слои вливаются в дочерние.
|
||||
|
||||
## flatten
|
||||
|
||||
`vitastor-cli flatten <layer>`
|
||||
|
||||
Сделай образ `<layer>` плоским, то есть, скопировать в него данные и разорвать его
|
||||
соединение с родительскими.
|
||||
|
||||
## rm-data
|
||||
|
||||
`vitastor-cli rm-data --pool <pool> --inode <inode> [--wait-list] [--min-offset <offset>]`
|
||||
|
||||
Удалить данные инода, не меняя метаданные образов.
|
||||
|
||||
```
|
||||
--wait-list Сначала запросить полный листинг объектов, а потом начать удалять.
|
||||
Требует больше памяти, но позволяет правильно печатать прогресс удаления.
|
||||
--min-offset Удалять только данные, начиная с заданного смещения.
|
||||
```
|
||||
|
||||
## merge-data
|
||||
|
||||
`vitastor-cli merge-data <from> <to> [--target <target>]`
|
||||
|
||||
Слить данные слоёв, не меняя метаданные. Вливает данные из слоёв от `<from>` до `<to>`
|
||||
в целевой образ `<target>`. `<to>` должен быть дочерним образом `<from>`, а `<target>`
|
||||
должен быть одним из слоёв между `<from>` и `<to>`, включая сами `<from>` и `<to>`.
|
||||
|
||||
## alloc-osd
|
||||
|
||||
`vitastor-cli alloc-osd`
|
||||
|
||||
Атомарно выделить новый номер OSD и зарезервировать его, создав в etcd пустой
|
||||
ключ `/osd/stats/<n>`.
|
||||
|
||||
## simple-offsets
|
||||
|
||||
`vitastor-cli simple-offsets <device>`
|
||||
|
||||
Рассчитать смещения для простого и тупого создания OSD на диске (без суперблока).
|
||||
|
||||
Опции (см. также [Дисковые параметры уровня кластера](../config/layout-cluster.ru.md)):
|
||||
|
||||
```
|
||||
--object_size 128k Размер блока хранилища
|
||||
--bitmap_granularity 4k Гранулярность битовых карт
|
||||
--journal_size 32M Размер журнала
|
||||
--device_block_size 4k Размер блока устройства
|
||||
--journal_offset 0 Смещение журнала
|
||||
--device_size 0 Размер устройства
|
||||
--format text Формат результата: json, options, env или text
|
||||
```
|
|
@ -1,197 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Использование → Консольный интерфейс Vitastor
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](cli.en.md)
|
||||
|
||||
# Консольный интерфейс Vitastor
|
||||
|
||||
vitastor-cli - интерфейс командной строки для административных задач, таких, как
|
||||
управление образами дисков.
|
||||
|
||||
Поддерживаются следующие команды:
|
||||
|
||||
- [status](#status)
|
||||
- [df](#df)
|
||||
- [ls](#ls)
|
||||
- [create](#create)
|
||||
- [modify](#modify)
|
||||
- [rm](#rm)
|
||||
- [flatten](#flatten)
|
||||
- [rm-data](#rm-data)
|
||||
- [merge-data](#merge-data)
|
||||
- [alloc-osd](#alloc-osd)
|
||||
- [simple-offsets](#simple-offsets)
|
||||
|
||||
Глобальные опции:
|
||||
|
||||
```
|
||||
--etcd_address ADDR Адрес соединения с etcd
|
||||
--iodepth N Отправлять параллельно N операций на каждый OSD (по умолчанию 32)
|
||||
--parallel_osds M Работать параллельно с M OSD (по умолчанию 4)
|
||||
--progress 1|0 Печатать прогресс выполнения (по умолчанию 1)
|
||||
--cas 1|0 Для команд flatten, merge, rm - использовать CAS при записи (по умолчанию - решение принимается автоматически)
|
||||
--no-color Отключить цветной вывод
|
||||
--json Включить JSON-вывод
|
||||
```
|
||||
|
||||
## status
|
||||
|
||||
`vitastor-cli status`
|
||||
|
||||
Show cluster status.
|
||||
|
||||
Example output:
|
||||
|
||||
```
|
||||
cluster:
|
||||
etcd: 1 / 1 up, 1.8 M database size
|
||||
mon: 1 up, master stump
|
||||
osd: 8 / 12 up
|
||||
|
||||
data:
|
||||
raw: 498.5 G used, 301.2 G / 799.7 G available, 399.8 G down
|
||||
state: 156.6 G clean, 97.6 G misplaced
|
||||
pools: 2 / 3 active
|
||||
pgs: 30 active
|
||||
34 active+has_misplaced
|
||||
32 offline
|
||||
|
||||
io:
|
||||
client: 0 B/s rd, 0 op/s rd, 0 B/s wr, 0 op/s wr
|
||||
rebalance: 989.8 M/s, 7.9 K op/s
|
||||
```
|
||||
|
||||
## df
|
||||
|
||||
`vitastor-cli df`
|
||||
|
||||
Show pool space statistics.
|
||||
|
||||
Example output:
|
||||
|
||||
```
|
||||
NAME SCHEME PGS TOTAL USED AVAILABLE USED% EFFICIENCY
|
||||
testpool 2/1 32 100 G 34.2 G 60.7 G 39.23% 100%
|
||||
size1 1/1 32 199.9 G 10 G 121.5 G 39.23% 100%
|
||||
kaveri 2/1 32 0 B 10 G 0 B 100% 0%
|
||||
```
|
||||
|
||||
In the example above, "kaveri" pool has "zero" efficiency because all its OSD are down.
|
||||
|
||||
## ls
|
||||
|
||||
`vitastor-cli ls [-l] [-p POOL] [--sort FIELD] [-r] [-n N] [<glob> ...]`
|
||||
|
||||
List images (only matching `<glob>` pattern(s) if passed).
|
||||
|
||||
Options:
|
||||
|
||||
```
|
||||
-p|--pool POOL Filter images by pool ID or name
|
||||
-l|--long Also report allocated size and I/O statistics
|
||||
--del Also include delete operation statistics
|
||||
--sort FIELD Sort by specified field (name, size, used_size, <read|write|delete>_<iops|bps|lat|queue>)
|
||||
-r|--reverse Sort in descending order
|
||||
-n|--count N Only list first N items
|
||||
```
|
||||
|
||||
Example output:
|
||||
|
||||
```
|
||||
NAME POOL SIZE USED READ IOPS QUEUE LAT WRITE IOPS QUEUE LAT FLAGS PARENT
|
||||
debian9 testpool 20 G 12.3 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us RO
|
||||
pve/vm-100-disk-0 testpool 20 G 0 B 0 B/s 0 0 0 us 0 B/s 0 0 0 us - debian9
|
||||
pve/base-101-disk-0 testpool 20 G 0 B 0 B/s 0 0 0 us 0 B/s 0 0 0 us RO debian9
|
||||
pve/vm-102-disk-0 testpool 32 G 36.4 M 0 B/s 0 0 0 us 0 B/s 0 0 0 us - pve/base-101-disk-0
|
||||
debian9-test testpool 20 G 36.6 M 0 B/s 0 0 0 us 0 B/s 0 0 0 us - debian9
|
||||
bench testpool 10 G 10 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us -
|
||||
bench-kaveri kaveri 10 G 10 G 0 B/s 0 0 0 us 0 B/s 0 0 0 us -
|
||||
```
|
||||
|
||||
## create
|
||||
|
||||
`vitastor-cli create -s|--size <size> [-p|--pool <id|name>] [--parent <parent_name>[@<snapshot>]] <name>`
|
||||
|
||||
Create an image. You may use K/M/G/T suffixes for `<size>`. If `--parent` is specified,
|
||||
a copy-on-write image clone is created. Parent must be a snapshot (readonly image).
|
||||
Pool must be specified if there is more than one pool.
|
||||
|
||||
```
|
||||
vitastor-cli create --snapshot <snapshot> [-p|--pool <id|name>] <image>
|
||||
vitastor-cli snap-create [-p|--pool <id|name>] <image>@<snapshot>
|
||||
```
|
||||
|
||||
Create a snapshot of image `<name>` (either form can be used). May be used live if only a single writer is active.
|
||||
|
||||
## modify
|
||||
|
||||
`vitastor-cli modify <name> [--rename <new-name>] [--resize <size>] [--readonly | --readwrite] [-f|--force]`
|
||||
|
||||
Rename, resize image or change its readonly status. Images with children can't be made read-write.
|
||||
If the new size is smaller than the old size, extra data will be purged.
|
||||
You should resize file system in the image, if present, before shrinking it.
|
||||
|
||||
```
|
||||
-f|--force Proceed with shrinking or setting readwrite flag even if the image has children.
|
||||
```
|
||||
|
||||
## rm
|
||||
|
||||
`vitastor-cli rm <from> [<to>] [--writers-stopped]`
|
||||
|
||||
Remove `<from>` or all layers between `<from>` and `<to>` (`<to>` must be a child of `<from>`),
|
||||
rebasing all their children accordingly. --writers-stopped allows merging to be a bit
|
||||
more effective in case of a single 'slim' read-write child and 'fat' removed parent:
|
||||
the child is merged into parent and parent is renamed to child in that case.
|
||||
In other cases parent layers are always merged into children.
|
||||
|
||||
## flatten
|
||||
|
||||
`vitastor-cli flatten <layer>`
|
||||
|
||||
Flatten a layer, i.e. merge data and detach it from parents.
|
||||
|
||||
## rm-data
|
||||
|
||||
`vitastor-cli rm-data --pool <pool> --inode <inode> [--wait-list] [--min-offset <offset>]`
|
||||
|
||||
Remove inode data without changing metadata.
|
||||
|
||||
```
|
||||
--wait-list Retrieve full objects listings before starting to remove objects.
|
||||
Requires more memory, but allows to show correct removal progress.
|
||||
--min-offset Purge only data starting with specified offset.
|
||||
```
|
||||
|
||||
## merge-data
|
||||
|
||||
`vitastor-cli merge-data <from> <to> [--target <target>]`
|
||||
|
||||
Merge layer data without changing metadata. Merge `<from>`..`<to>` to `<target>`.
|
||||
`<to>` must be a child of `<from>` and `<target>` may be one of the layers between
|
||||
`<from>` and `<to>`, including `<from>` and `<to>`.
|
||||
|
||||
## alloc-osd
|
||||
|
||||
`vitastor-cli alloc-osd`
|
||||
|
||||
Allocate a new OSD number and reserve it by creating empty `/osd/stats/<n>` key.
|
||||
|
||||
## simple-offsets
|
||||
|
||||
`vitastor-cli simple-offsets <device>`
|
||||
|
||||
Calculate offsets for simple&stupid (no superblock) OSD deployment.
|
||||
|
||||
Options (see also [Cluster-Wide Disk Layout Parameters](../config/layout-cluster.en.md)):
|
||||
|
||||
```
|
||||
--object_size 128k Set blockstore block size
|
||||
--bitmap_granularity 4k Set bitmap granularity
|
||||
--journal_size 32M Set journal size
|
||||
--device_block_size 4k Set device block size
|
||||
--journal_offset 0 Set journal offset
|
||||
--device_size 0 Set device size
|
||||
--format text Result format: json, options, env, or text
|
||||
```
|
|
@ -1,23 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Usage → fio driver
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](fio.ru.md)
|
||||
|
||||
# fio driver
|
||||
|
||||
[fio](https://fio.readthedocs.io/en/latest/fio_doc.html) (Flexible I/O tester) is the
|
||||
best utility for benchmarking block devices.
|
||||
|
||||
Vitastor has a fio driver which can be installed from the package vitastor-fio.
|
||||
|
||||
Use the following command as an example to run tests with fio against a Vitastor cluster:
|
||||
|
||||
```
|
||||
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
|
||||
```
|
||||
|
||||
If you don't want to access your image by name, you can specify pool number, inode number and size
|
||||
(`-pool=1 -inode=1 -size=400G`) instead of the image name (`-image=testimg`).
|
||||
|
||||
See exact fio commands to use for benchmarking [here](../performance/understanding.en.md#команды-fio).
|
|
@ -1,23 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Использование → Драйвер fio
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](fio.en.md)
|
||||
|
||||
# Драйвер fio
|
||||
|
||||
[fio](https://fio.readthedocs.io/en/latest/fio_doc.html) (Flexible I/O tester) - лучшая
|
||||
актуальная утилита для тестирования производительности блочных устройств.
|
||||
|
||||
В Vitastor есть драйвер для fio, устанавливаемый из пакета vitastor-fio.
|
||||
|
||||
Используйте следующую команду как пример для запуска тестов кластера Vitastor через fio:
|
||||
|
||||
```
|
||||
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
|
||||
```
|
||||
|
||||
Вместо обращения к образу по имени (`-image=testimg`) можно указать номер пула, номер инода и размер:
|
||||
`-pool=1 -inode=1 -size=400G`.
|
||||
|
||||
Конкретные команды fio для тестирования производительности можно посмотреть [здесь](../performance/understanding.ru.md#команды-fio).
|
|
@ -1,34 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Usage → NBD
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](nbd.ru.md)
|
||||
|
||||
# NBD
|
||||
|
||||
NBD stands for "Network Block Device", but in fact it also functions as "BUSE"
|
||||
(Block Device in UserSpace). NBD is currently required to mount Vitastor via kernel.
|
||||
NBD slighly lowers the performance due to additional overhead, but performance still
|
||||
remains decent (see an example [here](../performance/comparison1.en.md#vitastor-0-4-0-nbd)).
|
||||
|
||||
Vitastor Kubernetes CSI driver is based on NBD.
|
||||
|
||||
## Map image
|
||||
|
||||
To create a local block device for a Vitastor image run:
|
||||
|
||||
```
|
||||
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
|
||||
```
|
||||
|
||||
It will output a block device name like /dev/nbd0 which you can then use as a normal disk.
|
||||
|
||||
You can also use `--pool <POOL> --inode <INODE> --size <SIZE>` instead of `--image <IMAGE>` if you want.
|
||||
|
||||
## Unmap image
|
||||
|
||||
To unmap the device run:
|
||||
|
||||
```
|
||||
vitastor-nbd unmap /dev/nbd0
|
||||
```
|
|
@ -1,39 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Использование → NBD
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](nbd.en.md)
|
||||
|
||||
# NBD
|
||||
|
||||
NBD расшифровывается как "сетевое блочное устройство", но на самом деле оно также
|
||||
работает просто как аналог FUSE для блочных устройств, то есть, представляет собой
|
||||
"блочное устройство в пространстве пользователя".
|
||||
|
||||
NBD на данный момент необходимо, чтобы монтировать диски Vitastor ядром Linux.
|
||||
NBD немного снижает производительность из-за дополнительных копирований памяти,
|
||||
но она всё равно остаётся на неплохом уровне (см. для примера [тест](../performance/comparison1.ru.md#vitastor-0-4-0-nbd)).
|
||||
|
||||
CSI-драйвер Kubernetes Vitastor основан на NBD.
|
||||
|
||||
## Подключить устройство
|
||||
|
||||
Чтобы создать локальное блочное устройство для образа, выполните команду:
|
||||
|
||||
```
|
||||
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
|
||||
```
|
||||
|
||||
Команда напечатает название блочного устройства вида /dev/nbd0, которое потом можно
|
||||
будет использовать как обычный диск.
|
||||
|
||||
Для обращения по номеру инода, аналогично другим командам, можно использовать опции
|
||||
`--pool <POOL> --inode <INODE> --size <SIZE>` вместо `--image testimg`.
|
||||
|
||||
## Отключить устройство
|
||||
|
||||
Для отключения устройства выполните:
|
||||
|
||||
```
|
||||
vitastor-nbd unmap /dev/nbd0
|
||||
```
|
|
@ -1,45 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Usage → NFS
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](nfs.ru.md)
|
||||
|
||||
# NFS
|
||||
|
||||
Vitastor has a simplified NFS 3.0 proxy for file-based image access emulation. It's not
|
||||
suitable as a full-featured file system, at least because all file/image metadata is stored
|
||||
in etcd and kept in memory all the time - thus you can't put a lot of files in it.
|
||||
|
||||
However, NFS proxy is totally fine as a method to provide VM image access and allows to
|
||||
plug Vitastor into, for example, VMWare. It's important to note that for VMWare it's a much
|
||||
better access method than iSCSI, because with iSCSI we'd have to put all VM images into one
|
||||
Vitastor image exported as a LUN to VMWare and formatted with VMFS. VMWare doesn't use VMFS
|
||||
over NFS.
|
||||
|
||||
NFS proxy is stateless if you use immediate_commit=all mode (for SSD with capacitors or
|
||||
HDDs with disabled cache), so you can run multiple NFS proxies and use a network load
|
||||
balancer or any failover method you want to in that case.
|
||||
|
||||
vitastor-nfs usage:
|
||||
|
||||
```
|
||||
vitastor-nfs [--etcd_address ADDR] [OTHER OPTIONS]
|
||||
|
||||
--subdir <DIR> export images prefixed <DIR>/ (default empty - export all images)
|
||||
--portmap 0 do not listen on port 111 (portmap/rpcbind, requires root)
|
||||
--bind <IP> bind service to <IP> address (default 0.0.0.0)
|
||||
--nfspath <PATH> set NFS export path to <PATH> (default is /)
|
||||
--port <PORT> use port <PORT> for NFS services (default is 2049)
|
||||
--pool <POOL> use <POOL> as default pool for new files (images)
|
||||
--foreground 1 stay in foreground, do not daemonize
|
||||
```
|
||||
|
||||
Example start and mount commands:
|
||||
|
||||
```
|
||||
vitastor-nfs --etcd_address 192.168.5.10:2379 --portmap 0 --port 2050 --pool testpool
|
||||
```
|
||||
|
||||
```
|
||||
mount localhost:/ /mnt/ -o port=2050,mountport=2050,nfsvers=3,soft,nolock,tcp
|
||||
```
|
|
@ -1,44 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Использование → NFS
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](nfs.en.md)
|
||||
|
||||
# NFS
|
||||
|
||||
В Vitastor реализована упрощённая NFS 3.0 прокси для эмуляции файлового доступа к образам.
|
||||
Это не полноценная файловая система, т.к. метаданные всех файлов (образов) сохраняются
|
||||
в etcd и всё время хранятся в оперативной памяти - то есть, положить туда много файлов
|
||||
не получится.
|
||||
|
||||
Однако в качестве способа доступа к образам виртуальных машин NFS прокси прекрасно подходит
|
||||
и позволяет подключить Vitastor, например, к VMWare.
|
||||
|
||||
При этом, если вы используете режим immediate_commit=all (для SSD с конденсаторами или HDD
|
||||
с отключённым кэшем), то NFS-сервер не имеет состояния и вы можете свободно поднять
|
||||
его в нескольких экземплярах и использовать поверх них сетевой балансировщик нагрузки или
|
||||
схему с отказоустойчивостью.
|
||||
|
||||
Использование vitastor-nfs:
|
||||
|
||||
```
|
||||
vitastor-nfs [--etcd_address ADDR] [ДРУГИЕ ОПЦИИ]
|
||||
|
||||
--subdir <DIR> экспортировать "поддиректорию" - образы с префиксом имени <DIR>/ (по умолчанию пусто - экспортировать все образы)
|
||||
--portmap 0 отключить сервис portmap/rpcbind на порту 111 (по умолчанию включён и требует root привилегий)
|
||||
--bind <IP> принимать соединения по адресу <IP> (по умолчанию 0.0.0.0 - на всех)
|
||||
--nfspath <PATH> установить путь NFS-экспорта в <PATH> (по умолчанию /)
|
||||
--port <PORT> использовать порт <PORT> для NFS-сервисов (по умолчанию 2049)
|
||||
--pool <POOL> исползовать пул <POOL> для новых образов (обязательно, если пул в кластере не один)
|
||||
--foreground 1 не уходить в фон после запуска
|
||||
```
|
||||
|
||||
Пример монтирования Vitastor через NFS:
|
||||
|
||||
```
|
||||
vitastor-nfs --etcd_address 192.168.5.10:2379 --portmap 0 --port 2050 --pool testpool
|
||||
```
|
||||
|
||||
```
|
||||
mount localhost:/ /mnt/ -o port=2050,mountport=2050,nfsvers=3,soft,nolock,tcp
|
||||
```
|
|
@ -1,48 +0,0 @@
|
|||
[Documentation](../../README.md#documentation) → Usage → QEMU and qemu-img
|
||||
|
||||
-----
|
||||
|
||||
[Читать на русском](qemu.ru.md)
|
||||
|
||||
# QEMU and qemu-img
|
||||
|
||||
## QEMU
|
||||
|
||||
You need patched QEMU version to use Vitastor driver. Pre-built [packages](../installation/packages.en.md) are available.
|
||||
|
||||
To start a VM using plain QEMU command-line with Vitastor disk, use the following commands:
|
||||
|
||||
Old syntax (-drive):
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024 \
|
||||
-drive 'file=vitastor:etcd_host=192.168.7.2\:2379/v3:image=debian9',
|
||||
format=raw,if=none,id=drive-virtio-disk0,cache=none \
|
||||
-device 'virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,
|
||||
id=virtio-disk0,bootindex=1,write-cache=off' \
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
New syntax (-blockdev):
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024 \
|
||||
-blockdev '{"node-name":"drive-virtio-disk0","driver":"vitastor","image":"debian9",
|
||||
"cache":{"direct":true,"no-flush":false},"auto-read-only":true,"discard":"unmap"}' \
|
||||
-device 'virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,
|
||||
id=virtio-disk0,bootindex=1,write-cache=off' \
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
## qemu-img
|
||||
|
||||
For qemu-img, you should use `vitastor:etcd_host=<HOST>:image=<IMAGE>` as filename.
|
||||
|
||||
For example, to upload a VM image into Vitastor, run:
|
||||
|
||||
```
|
||||
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=192.168.7.2\:2379/v3:image=debian10'
|
||||
```
|
||||
|
||||
You can also specify `:pool=<POOL>:inode=<INODE>:size=<SIZE>` instead of `:image=<IMAGE>`
|
||||
if you don't want to use inode metadata.
|
|
@ -1,52 +0,0 @@
|
|||
[Документация](../../README-ru.md#документация) → Использование → QEMU и qemu-img
|
||||
|
||||
-----
|
||||
|
||||
[Read in English](qemu.en.md)
|
||||
|
||||
# QEMU и qemu-img
|
||||
|
||||
## QEMU
|
||||
|
||||
Чтобы использовать Vitastor-диски в QEMU, вам нужна доработанная версия QEMU.
|
||||
Её можно установить [из пакетов](../installation/packages.ru.md).
|
||||
|
||||
Для ручного запуска виртуальной машины QEMU из командной строки с Vitastor-диском
|
||||
используйте один из следующих вариантов команд:
|
||||
|
||||
Старый синтаксис (-drive):
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024 \
|
||||
-drive 'file=vitastor:etcd_host=192.168.7.2\:2379/v3:image=debian9',
|
||||
format=raw,if=none,id=drive-virtio-disk0,cache=none \
|
||||
-device 'virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,
|
||||
id=virtio-disk0,bootindex=1,write-cache=off' \
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
Новый синтаксис (-blockdev):
|
||||
|
||||
```
|
||||
qemu-system-x86_64 -enable-kvm -m 1024 \
|
||||
-blockdev '{"node-name":"drive-virtio-disk0","driver":"vitastor","image":"debian9",
|
||||
"cache":{"direct":true,"no-flush":false},"auto-read-only":true,"discard":"unmap"}' \
|
||||
-device 'virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,
|
||||
id=virtio-disk0,bootindex=1,write-cache=off' \
|
||||
-vnc 0.0.0.0:0
|
||||
```
|
||||
|
||||
Вместо `:image=<IMAGE>` также можно указывать номер инода, пул и размер: `:pool=<POOL>:inode=<INODE>:size=<SIZE>`.
|
||||
|
||||
## qemu-img
|
||||
|
||||
Для qemu-img используйте строку `vitastor:etcd_host=<HOST>:image=<IMAGE>` в качестве имени файла диска.
|
||||
|
||||
Например, чтобы загрузить образ диска в Vitastor:
|
||||
|
||||
```
|
||||
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg'
|
||||
```
|
||||
|
||||
Если вы не хотите обращаться к образу по имени, вместо `:image=<IMAGE>` можно указать номер пула, номер инода и размер:
|
||||
`:pool=<POOL>:inode=<INODE>:size=<SIZE>`.
|
|
@ -0,0 +1 @@
|
|||
Subproject commit 5a991e1fcbcdcca9a191c8e377b4cfb89142761e
|
65
mon/mon.js
65
mon/mon.js
|
@ -160,8 +160,6 @@ const etcd_tree = {
|
|||
root_node?: 'rack1',
|
||||
// restrict pool to OSDs having all of these tags
|
||||
osd_tags?: 'nvme' | [ 'nvme', ... ],
|
||||
// prefer to put primary on OSD with these tags
|
||||
primary_affinity_tags?: 'nvme' | [ 'nvme', ... ],
|
||||
},
|
||||
...
|
||||
}, */
|
||||
|
@ -226,19 +224,15 @@ const etcd_tree = {
|
|||
}, */
|
||||
},
|
||||
inodestats: {
|
||||
/* <pool_id>: {
|
||||
<inode_t>: {
|
||||
read: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
write: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
delete: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
},
|
||||
/* <inode_t>: {
|
||||
read: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
write: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
delete: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
||||
}, */
|
||||
},
|
||||
space: {
|
||||
/* <osd_num_t>: {
|
||||
<pool_id>: {
|
||||
<inode_t>: uint64_t, // bytes
|
||||
},
|
||||
<inode_t>: uint64_t, // bytes
|
||||
}, */
|
||||
},
|
||||
},
|
||||
|
@ -905,39 +899,27 @@ class Mon
|
|||
return this.seed + 2147483648;
|
||||
}
|
||||
|
||||
pick_primary(pool_id, osd_set, up_osds, aff_osds)
|
||||
pick_primary(pool_id, osd_set, up_osds)
|
||||
{
|
||||
let alive_set;
|
||||
if (this.state.config.pools[pool_id].scheme === 'replicated')
|
||||
{
|
||||
// Prefer "affinity" OSDs
|
||||
alive_set = osd_set.filter(osd_num => osd_num && aff_osds[osd_num]);
|
||||
if (!alive_set.length)
|
||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
}
|
||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
else
|
||||
{
|
||||
// Prefer data OSDs for EC because they can actually read something without an additional network hop
|
||||
const pg_data_size = (this.state.config.pools[pool_id].pg_size||0) -
|
||||
(this.state.config.pools[pool_id].parity_chunks||0);
|
||||
alive_set = osd_set.slice(0, pg_data_size).filter(osd_num => osd_num && aff_osds[osd_num]);
|
||||
alive_set = osd_set.slice(0, pg_data_size).filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
if (!alive_set.length)
|
||||
alive_set = osd_set.filter(osd_num => osd_num && aff_osds[osd_num]);
|
||||
if (!alive_set.length)
|
||||
{
|
||||
alive_set = osd_set.slice(0, pg_data_size).filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
if (!alive_set.length)
|
||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
}
|
||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
||||
}
|
||||
if (!alive_set.length)
|
||||
return 0;
|
||||
return alive_set[this.rng() % alive_set.length];
|
||||
}
|
||||
|
||||
save_new_pgs_txn(request, pool_id, up_osds, osd_tree, prev_pgs, new_pgs, pg_history)
|
||||
save_new_pgs_txn(request, pool_id, up_osds, prev_pgs, new_pgs, pg_history)
|
||||
{
|
||||
const aff_osds = this.get_affinity_osds(this.state.config.pools[pool_id], up_osds, osd_tree);
|
||||
const pg_items = {};
|
||||
this.reset_rng();
|
||||
new_pgs.map((osd_set, i) =>
|
||||
|
@ -945,7 +927,7 @@ class Mon
|
|||
osd_set = osd_set.map(osd_num => osd_num === LPOptimizer.NO_OSD ? 0 : osd_num);
|
||||
pg_items[i+1] = {
|
||||
osd_set,
|
||||
primary: this.pick_primary(pool_id, osd_set, up_osds, aff_osds),
|
||||
primary: this.pick_primary(pool_id, osd_set, up_osds),
|
||||
};
|
||||
if (prev_pgs[i] && prev_pgs[i].join(' ') != osd_set.join(' ') &&
|
||||
prev_pgs[i].filter(osd_num => osd_num).length > 0)
|
||||
|
@ -1076,13 +1058,6 @@ class Mon
|
|||
console.log('Pool '+pool_id+' has invalid osd_tags (must be a string or array of strings)');
|
||||
return false;
|
||||
}
|
||||
if (pool_cfg.primary_affinity_tags && typeof(pool_cfg.primary_affinity_tags) != 'string' &&
|
||||
(!(pool_cfg.primary_affinity_tags instanceof Array) || pool_cfg.primary_affinity_tags.filter(t => typeof t != 'string').length > 0))
|
||||
{
|
||||
if (warn)
|
||||
console.log('Pool '+pool_id+' has invalid primary_affinity_tags (must be a string or array of strings)');
|
||||
return false;
|
||||
}
|
||||
return true;
|
||||
}
|
||||
|
||||
|
@ -1112,17 +1087,6 @@ class Mon
|
|||
}
|
||||
}
|
||||
|
||||
get_affinity_osds(pool_cfg, up_osds, osd_tree)
|
||||
{
|
||||
let aff_osds = up_osds;
|
||||
if (pool_cfg.primary_affinity_tags)
|
||||
{
|
||||
aff_osds = { ...up_osds };
|
||||
this.filter_osds_by_tags(osd_tree, { x: aff_osds }, pool_cfg.primary_affinity_tags);
|
||||
}
|
||||
return aff_osds;
|
||||
}
|
||||
|
||||
async recheck_pgs()
|
||||
{
|
||||
// Take configuration and state, check it against the stored configuration hash
|
||||
|
@ -1153,7 +1117,7 @@ class Mon
|
|||
{
|
||||
prev_pgs[pg-1] = this.state.config.pgs.items[pool_id][pg].osd_set;
|
||||
}
|
||||
this.save_new_pgs_txn(etcd_request, pool_id, up_osds, osd_tree, prev_pgs, [], []);
|
||||
this.save_new_pgs_txn(etcd_request, pool_id, up_osds, prev_pgs, [], []);
|
||||
}
|
||||
}
|
||||
for (const pool_id in this.state.config.pools)
|
||||
|
@ -1260,7 +1224,7 @@ class Mon
|
|||
key: b64(this.etcd_prefix+'/pool/stats/'+pool_id),
|
||||
value: b64(JSON.stringify(this.state.pool.stats[pool_id])),
|
||||
} });
|
||||
this.save_new_pgs_txn(etcd_request, pool_id, up_osds, osd_tree, real_prev_pgs, optimize_result.int_pgs, pg_history);
|
||||
this.save_new_pgs_txn(etcd_request, pool_id, up_osds, real_prev_pgs, optimize_result.int_pgs, pg_history);
|
||||
}
|
||||
this.state.config.pgs.hash = tree_hash;
|
||||
await this.save_pg_config(etcd_request);
|
||||
|
@ -1277,14 +1241,13 @@ class Mon
|
|||
continue;
|
||||
}
|
||||
const replicated = pool_cfg.scheme === 'replicated';
|
||||
const aff_osds = this.get_affinity_osds(pool_cfg, up_osds, osd_tree);
|
||||
this.reset_rng();
|
||||
for (let pg_num = 1; pg_num <= pool_cfg.pg_count; pg_num++)
|
||||
{
|
||||
const pg_cfg = this.state.config.pgs.items[pool_id][pg_num];
|
||||
if (pg_cfg)
|
||||
{
|
||||
const new_primary = this.pick_primary(pool_id, pg_cfg.osd_set, up_osds, aff_osds);
|
||||
const new_primary = this.pick_primary(pool_id, pg_cfg.osd_set, up_osds);
|
||||
if (pg_cfg.primary != new_primary)
|
||||
{
|
||||
console.log(
|
||||
|
|
|
@ -50,7 +50,7 @@ from cinder.volume import configuration
|
|||
from cinder.volume import driver
|
||||
from cinder.volume import volume_utils
|
||||
|
||||
VERSION = '0.6.17'
|
||||
VERSION = '0.6.16'
|
||||
|
||||
LOG = logging.getLogger(__name__)
|
||||
|
||||
|
|
|
@ -25,4 +25,4 @@ rm fio
|
|||
mv fio-copy fio
|
||||
FIO=`rpm -qi fio | perl -e 'while(<>) { /^Epoch[\s:]+(\S+)/ && print "$1:"; /^Version[\s:]+(\S+)/ && print $1; /^Release[\s:]+(\S+)/ && print "-$1"; }'`
|
||||
perl -i -pe 's/(Requires:\s*fio)([^\n]+)?/$1 = '$FIO'/' $VITASTOR/rpm/vitastor-el$EL.spec
|
||||
tar --transform 's#^#vitastor-0.6.17/#' --exclude 'rpm/*.rpm' -czf $VITASTOR/../vitastor-0.6.17$(rpm --eval '%dist').tar.gz *
|
||||
tar --transform 's#^#vitastor-0.6.16/#' --exclude 'rpm/*.rpm' -czf $VITASTOR/../vitastor-0.6.16$(rpm --eval '%dist').tar.gz *
|
||||
|
|
|
@ -34,7 +34,7 @@ ADD . /root/vitastor
|
|||
RUN set -e; \
|
||||
cd /root/vitastor/rpm; \
|
||||
sh build-tarball.sh; \
|
||||
cp /root/vitastor-0.6.17.el7.tar.gz ~/rpmbuild/SOURCES; \
|
||||
cp /root/vitastor-0.6.16.el7.tar.gz ~/rpmbuild/SOURCES; \
|
||||
cp vitastor-el7.spec ~/rpmbuild/SPECS/vitastor.spec; \
|
||||
cd ~/rpmbuild/SPECS/; \
|
||||
rpmbuild -ba vitastor.spec; \
|
||||
|
|
|
@ -1,11 +1,11 @@
|
|||
Name: vitastor
|
||||
Version: 0.6.17
|
||||
Version: 0.6.16
|
||||
Release: 1%{?dist}
|
||||
Summary: Vitastor, a fast software-defined clustered block storage
|
||||
|
||||
License: Vitastor Network Public License 1.1
|
||||
URL: https://vitastor.io/
|
||||
Source0: vitastor-0.6.17.el7.tar.gz
|
||||
Source0: vitastor-0.6.16.el7.tar.gz
|
||||
|
||||
BuildRequires: liburing-devel >= 0.6
|
||||
BuildRequires: gperftools-devel
|
||||
|
@ -119,7 +119,6 @@ cp -r mon %buildroot/usr/lib/vitastor
|
|||
|
||||
%files -n vitastor-client
|
||||
%_bindir/vitastor-nbd
|
||||
%_bindir/vitastor-nfs
|
||||
%_bindir/vitastor-cli
|
||||
%_bindir/vitastor-rm
|
||||
%_bindir/vita
|
||||
|
|
|
@ -33,7 +33,7 @@ ADD . /root/vitastor
|
|||
RUN set -e; \
|
||||
cd /root/vitastor/rpm; \
|
||||
sh build-tarball.sh; \
|
||||
cp /root/vitastor-0.6.17.el8.tar.gz ~/rpmbuild/SOURCES; \
|
||||
cp /root/vitastor-0.6.16.el8.tar.gz ~/rpmbuild/SOURCES; \
|
||||
cp vitastor-el8.spec ~/rpmbuild/SPECS/vitastor.spec; \
|
||||
cd ~/rpmbuild/SPECS/; \
|
||||
rpmbuild -ba vitastor.spec; \
|
||||
|
|
|
@ -1,11 +1,11 @@
|
|||
Name: vitastor
|
||||
Version: 0.6.17
|
||||
Version: 0.6.16
|
||||
Release: 1%{?dist}
|
||||
Summary: Vitastor, a fast software-defined clustered block storage
|
||||
|
||||
License: Vitastor Network Public License 1.1
|
||||
URL: https://vitastor.io/
|
||||
Source0: vitastor-0.6.17.el8.tar.gz
|
||||
Source0: vitastor-0.6.16.el8.tar.gz
|
||||
|
||||
BuildRequires: liburing-devel >= 0.6
|
||||
BuildRequires: gperftools-devel
|
||||
|
@ -116,7 +116,6 @@ cp -r mon %buildroot/usr/lib/vitastor
|
|||
|
||||
%files -n vitastor-client
|
||||
%_bindir/vitastor-nbd
|
||||
%_bindir/vitastor-nfs
|
||||
%_bindir/vitastor-cli
|
||||
%_bindir/vitastor-rm
|
||||
%_bindir/vita
|
||||
|
|
|
@ -15,7 +15,7 @@ if("${CMAKE_INSTALL_PREFIX}" MATCHES "^/usr/local/?$")
|
|||
set(CMAKE_INSTALL_RPATH "${CMAKE_INSTALL_PREFIX}/${CMAKE_INSTALL_LIBDIR}")
|
||||
endif()
|
||||
|
||||
add_definitions(-DVERSION="0.6.17")
|
||||
add_definitions(-DVERSION="0.6.16")
|
||||
add_definitions(-Wall -Wno-sign-compare -Wno-comment -Wno-parentheses -Wno-pointer-arith -fdiagnostics-color=always -I ${CMAKE_SOURCE_DIR}/src)
|
||||
if (${WITH_ASAN})
|
||||
add_definitions(-fsanitize=address -fno-omit-frame-pointer)
|
||||
|
@ -124,18 +124,6 @@ add_library(vitastor_client SHARED
|
|||
cluster_client.cpp
|
||||
cluster_client_list.cpp
|
||||
vitastor_c.cpp
|
||||
cli_common.cpp
|
||||
cli_alloc_osd.cpp
|
||||
cli_simple_offsets.cpp
|
||||
cli_status.cpp
|
||||
cli_df.cpp
|
||||
cli_ls.cpp
|
||||
cli_create.cpp
|
||||
cli_modify.cpp
|
||||
cli_flatten.cpp
|
||||
cli_merge.cpp
|
||||
cli_rm_data.cpp
|
||||
cli_rm.cpp
|
||||
)
|
||||
set_target_properties(vitastor_client PROPERTIES PUBLIC_HEADER "vitastor_c.h")
|
||||
target_link_libraries(vitastor_client
|
||||
|
@ -170,10 +158,56 @@ add_executable(vitastor-nfs
|
|||
nfs_conn.cpp
|
||||
nfs_portmap.cpp
|
||||
sha256.c
|
||||
nfs/xdr_impl.cpp
|
||||
nfs/rpc_xdr.cpp
|
||||
nfs/portmap_xdr.cpp
|
||||
nfs/nfs_xdr.cpp
|
||||
../libnfs/lib/init.c
|
||||
../libnfs/lib/pdu.c
|
||||
../libnfs/lib/libnfs-zdr.c
|
||||
../libnfs/lib/socket.c
|
||||
../libnfs/portmap/libnfs-raw-portmap.c
|
||||
../libnfs/nfs/libnfs-raw-nfs.c
|
||||
../libnfs/mount/libnfs-raw-mount.c
|
||||
)
|
||||
set_source_files_properties(
|
||||
../libnfs/nfs/libnfs-raw-nfs.c
|
||||
PROPERTIES
|
||||
COMPILE_FLAGS "-Wno-unused-but-set-variable"
|
||||
)
|
||||
# Simplified static configuration
|
||||
# The other option is to build patched libnfs packages until all distros get my fixes
|
||||
target_compile_options(vitastor-nfs
|
||||
PRIVATE
|
||||
-DHAVE_ARPA_INET_H
|
||||
-DHAVE_INTTYPES_H
|
||||
-DHAVE_MEMORY_H
|
||||
-DHAVE_NETDB_H
|
||||
-DHAVE_NETINET_IN_H
|
||||
-DHAVE_NETINET_TCP_H
|
||||
-DHAVE_NET_IF_H
|
||||
-DHAVE_POLL_H
|
||||
-DHAVE_STDINT_H
|
||||
-DHAVE_STDLIB_H
|
||||
-DHAVE_STRINGS_H
|
||||
-DHAVE_STRING_H
|
||||
-DHAVE_SYS_IOCTL_H
|
||||
-DHAVE_SYS_SOCKET_H
|
||||
-DHAVE_SYS_STATVFS_H
|
||||
-DHAVE_SYS_STAT_H
|
||||
-DHAVE_SYS_SYSMACROS_H
|
||||
-DHAVE_SYS_TIME_H
|
||||
-DHAVE_SYS_TYPES_H
|
||||
-DHAVE_SYS_VFS_H
|
||||
-DHAVE_UNISTD_H
|
||||
-DHAVE_UTIME_H
|
||||
-DHAVE_SOCKADDR_STORAGE
|
||||
-DHAVE_STRUCT_STAT_ST_MTIM_TV_NSEC
|
||||
-D_U_=
|
||||
)
|
||||
target_include_directories(vitastor-nfs
|
||||
PRIVATE
|
||||
../libnfs/include
|
||||
../libnfs/include/nfsc
|
||||
../libnfs/portmap
|
||||
../libnfs/nfs
|
||||
../libnfs/mount
|
||||
)
|
||||
target_link_libraries(vitastor-nfs
|
||||
vitastor_client
|
||||
|
@ -181,7 +215,8 @@ target_link_libraries(vitastor-nfs
|
|||
|
||||
# vitastor-cli
|
||||
add_executable(vitastor-cli
|
||||
cli.cpp
|
||||
cli.cpp cli_common.cpp cli_alloc_osd.cpp cli_simple_offsets.cpp cli_status.cpp cli_df.cpp
|
||||
cli_ls.cpp cli_create.cpp cli_modify.cpp cli_flatten.cpp cli_merge.cpp cli_rm_data.cpp cli_rm.cpp
|
||||
)
|
||||
target_link_libraries(vitastor-cli
|
||||
vitastor_client
|
||||
|
@ -270,7 +305,7 @@ target_include_directories(test_cluster_client PUBLIC ${CMAKE_SOURCE_DIR}/src/mo
|
|||
|
||||
### Install
|
||||
|
||||
install(TARGETS vitastor-osd vitastor-dump-journal vitastor-nbd vitastor-nfs vitastor-cli RUNTIME DESTINATION ${CMAKE_INSTALL_BINDIR})
|
||||
install(TARGETS vitastor-osd vitastor-dump-journal vitastor-nbd vitastor-cli RUNTIME DESTINATION ${CMAKE_INSTALL_BINDIR})
|
||||
install_symlink(vitastor-cli ${CMAKE_INSTALL_PREFIX}/${CMAKE_INSTALL_BINDIR}/vitastor-rm)
|
||||
install_symlink(vitastor-cli ${CMAKE_INSTALL_PREFIX}/${CMAKE_INSTALL_BINDIR}/vita)
|
||||
install(
|
||||
|
|
|
@ -131,7 +131,6 @@ resume_1:
|
|||
}
|
||||
// Skip superblock
|
||||
bs->meta_offset += bs->meta_block_size;
|
||||
bs->meta_len -= bs->meta_block_size;
|
||||
prev_done = 0;
|
||||
done_len = 0;
|
||||
done_pos = 0;
|
||||
|
|
147
src/cli.cpp
147
src/cli.cpp
|
@ -155,7 +155,7 @@ static void help()
|
|||
" --iodepth N Send N operations in parallel to each OSD when possible (default 32)\n"
|
||||
" --parallel_osds M Work with M osds in parallel when possible (default 4)\n"
|
||||
" --progress 1|0 Report progress (default 1)\n"
|
||||
" --cas 1|0 Use CAS writes for flatten, merge, rm (default is decide automatically)\n"
|
||||
" --cas 1|0 Use online CAS writes when possible (default auto)\n"
|
||||
" --no-color Disable colored output\n"
|
||||
" --json JSON output\n"
|
||||
,
|
||||
|
@ -165,16 +165,15 @@ static void help()
|
|||
exit(0);
|
||||
}
|
||||
|
||||
static int run(cli_tool_t *p, json11::Json::object cfg)
|
||||
static int run(cli_tool_t *p, json11::Json cfg)
|
||||
{
|
||||
cli_result_t result;
|
||||
p->parse_config(cfg);
|
||||
json11::Json::array cmd = cfg["command"].array_items();
|
||||
cfg.erase("command");
|
||||
std::function<bool(cli_result_t &)> action_cb;
|
||||
if (!cmd.size())
|
||||
{
|
||||
result = { .err = EINVAL, .text = "command is missing" };
|
||||
fprintf(stderr, "command is missing\n");
|
||||
return EINVAL;
|
||||
}
|
||||
else if (cmd[0] == "status")
|
||||
{
|
||||
|
@ -189,82 +188,37 @@ static int run(cli_tool_t *p, json11::Json::object cfg)
|
|||
else if (cmd[0] == "ls")
|
||||
{
|
||||
// List images
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cmd.erase(cmd.begin(), cmd.begin()+1);
|
||||
cfg["names"] = cmd;
|
||||
}
|
||||
action_cb = p->start_ls(cfg);
|
||||
}
|
||||
else if (cmd[0] == "snap-create")
|
||||
{
|
||||
// Create snapshot
|
||||
std::string name = cmd.size() > 1 ? cmd[1].string_value() : "";
|
||||
int pos = name.find('@');
|
||||
if (pos == std::string::npos || pos == name.length()-1)
|
||||
{
|
||||
result = (cli_result_t){ .err = EINVAL, .text = "Please specify new snapshot name after @" };
|
||||
}
|
||||
else
|
||||
{
|
||||
cfg["image"] = name.substr(0, pos);
|
||||
cfg["snapshot"] = name.substr(pos + 1);
|
||||
action_cb = p->start_create(cfg);
|
||||
}
|
||||
}
|
||||
else if (cmd[0] == "create")
|
||||
else if (cmd[0] == "create" || cmd[0] == "snap-create")
|
||||
{
|
||||
// Create image/snapshot
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["image"] = cmd[1];
|
||||
}
|
||||
action_cb = p->start_create(cfg);
|
||||
}
|
||||
else if (cmd[0] == "modify")
|
||||
{
|
||||
// Modify image
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["image"] = cmd[1];
|
||||
}
|
||||
action_cb = p->start_modify(cfg);
|
||||
}
|
||||
else if (cmd[0] == "rm-data")
|
||||
{
|
||||
// Delete inode data
|
||||
action_cb = p->start_rm_data(cfg);
|
||||
action_cb = p->start_rm(cfg);
|
||||
}
|
||||
else if (cmd[0] == "merge-data")
|
||||
{
|
||||
// Merge layer data without affecting metadata
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["from"] = cmd[1];
|
||||
if (cmd.size() > 2)
|
||||
cfg["to"] = cmd[2];
|
||||
}
|
||||
action_cb = p->start_merge(cfg);
|
||||
}
|
||||
else if (cmd[0] == "flatten")
|
||||
{
|
||||
// Merge layer data without affecting metadata
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["image"] = cmd[1];
|
||||
}
|
||||
action_cb = p->start_flatten(cfg);
|
||||
}
|
||||
else if (cmd[0] == "rm")
|
||||
{
|
||||
// Remove multiple snapshots and rebase their children
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["from"] = cmd[1];
|
||||
if (cmd.size() > 2)
|
||||
cfg["to"] = cmd[2];
|
||||
}
|
||||
action_cb = p->start_rm(cfg);
|
||||
action_cb = p->start_snap_rm(cfg);
|
||||
}
|
||||
else if (cmd[0] == "alloc-osd")
|
||||
{
|
||||
|
@ -274,61 +228,62 @@ static int run(cli_tool_t *p, json11::Json::object cfg)
|
|||
else if (cmd[0] == "simple-offsets")
|
||||
{
|
||||
// Calculate offsets for simple & stupid OSD deployment without superblock
|
||||
if (cmd.size() > 1)
|
||||
{
|
||||
cfg["device"] = cmd[1];
|
||||
}
|
||||
action_cb = p->simple_offsets(cfg);
|
||||
}
|
||||
else
|
||||
{
|
||||
result = { .err = EINVAL, .text = "unknown command: "+cmd[0].string_value() };
|
||||
fprintf(stderr, "unknown command: %s\n", cmd[0].string_value().c_str());
|
||||
return EINVAL;
|
||||
}
|
||||
if (action_cb != NULL)
|
||||
if (action_cb == NULL)
|
||||
{
|
||||
// Create client
|
||||
json11::Json cfg_j = cfg;
|
||||
p->ringloop = new ring_loop_t(512);
|
||||
p->epmgr = new epoll_manager_t(p->ringloop);
|
||||
p->cli = new cluster_client_t(p->ringloop, p->epmgr->tfd, cfg_j);
|
||||
// Smaller timeout by default for more interactiveness
|
||||
p->cli->st_cli.etcd_slow_timeout = p->cli->st_cli.etcd_quick_timeout;
|
||||
p->loop_and_wait(action_cb, [&](const cli_result_t & r)
|
||||
return 0;
|
||||
}
|
||||
// Create client
|
||||
p->ringloop = new ring_loop_t(512);
|
||||
p->epmgr = new epoll_manager_t(p->ringloop);
|
||||
p->cli = new cluster_client_t(p->ringloop, p->epmgr->tfd, cfg);
|
||||
// Smaller timeout by default for more interactiveness
|
||||
p->cli->st_cli.etcd_slow_timeout = p->cli->st_cli.etcd_quick_timeout;
|
||||
ring_consumer_t consumer;
|
||||
cli_result_t result;
|
||||
p->cli->on_ready([&]()
|
||||
{
|
||||
// Initialize job
|
||||
consumer.loop = [&]()
|
||||
{
|
||||
result = r;
|
||||
action_cb = NULL;
|
||||
});
|
||||
// Loop until it completes
|
||||
while (action_cb != NULL)
|
||||
{
|
||||
p->ringloop->loop();
|
||||
if (action_cb != NULL)
|
||||
p->ringloop->wait();
|
||||
}
|
||||
// Destroy the client
|
||||
delete p->cli;
|
||||
delete p->epmgr;
|
||||
delete p->ringloop;
|
||||
p->cli = NULL;
|
||||
p->epmgr = NULL;
|
||||
p->ringloop = NULL;
|
||||
{
|
||||
bool done = action_cb(result);
|
||||
if (done)
|
||||
{
|
||||
action_cb = NULL;
|
||||
}
|
||||
}
|
||||
p->ringloop->submit();
|
||||
};
|
||||
p->ringloop->register_consumer(&consumer);
|
||||
consumer.loop();
|
||||
});
|
||||
// Loop until it completes
|
||||
while (action_cb != NULL)
|
||||
{
|
||||
p->ringloop->loop();
|
||||
if (action_cb != NULL)
|
||||
p->ringloop->wait();
|
||||
}
|
||||
// Print result
|
||||
if (p->json_output && !result.data.is_null())
|
||||
if (result.text != "")
|
||||
{
|
||||
printf("%s\n", result.data.dump().c_str());
|
||||
}
|
||||
else if (p->json_output && result.err)
|
||||
{
|
||||
printf("%s\n", json11::Json(json11::Json::object {
|
||||
{ "error_code", result.err },
|
||||
{ "error_text", result.text },
|
||||
}).dump().c_str());
|
||||
}
|
||||
else if (result.text != "")
|
||||
{
|
||||
fprintf(result.err ? stderr : stdout, result.text[result.text.size()-1] == '\n' ? "%s" : "%s\n", result.text.c_str());
|
||||
fprintf(stderr, "%s\n", result.text.c_str());
|
||||
}
|
||||
// Destroy the client
|
||||
delete p->cli;
|
||||
delete p->epmgr;
|
||||
delete p->ringloop;
|
||||
p->cli = NULL;
|
||||
p->epmgr = NULL;
|
||||
p->ringloop = NULL;
|
||||
return result.err;
|
||||
}
|
||||
|
||||
|
|
14
src/cli.h
14
src/cli.h
|
@ -29,8 +29,8 @@ struct cli_result_t
|
|||
class cli_tool_t
|
||||
{
|
||||
public:
|
||||
uint64_t iodepth = 4, parallel_osds = 32;
|
||||
bool progress = false;
|
||||
uint64_t iodepth = 0, parallel_osds = 0;
|
||||
bool progress = true;
|
||||
bool list_first = false;
|
||||
bool json_output = false;
|
||||
int log_level = 0;
|
||||
|
@ -41,12 +41,11 @@ public:
|
|||
cluster_client_t *cli = NULL;
|
||||
|
||||
int waiting = 0;
|
||||
cli_result_t etcd_err;
|
||||
json11::Json etcd_result;
|
||||
|
||||
void parse_config(json11::Json cfg);
|
||||
|
||||
void change_parent(inode_t cur, inode_t new_parent, cli_result_t *result);
|
||||
void change_parent(inode_t cur, inode_t new_parent);
|
||||
inode_config_t* get_inode_cfg(const std::string & name);
|
||||
|
||||
friend struct rm_inode_t;
|
||||
|
@ -59,16 +58,13 @@ public:
|
|||
std::function<bool(cli_result_t &)> start_ls(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_create(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_modify(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_rm_data(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_rm(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_merge(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_flatten(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_rm(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_snap_rm(json11::Json);
|
||||
std::function<bool(cli_result_t &)> start_alloc_osd(json11::Json cfg);
|
||||
std::function<bool(cli_result_t &)> simple_offsets(json11::Json cfg);
|
||||
|
||||
// Should be called like loop_and_wait(start_status(), <completion callback>)
|
||||
void loop_and_wait(std::function<bool(cli_result_t &)> loop_cb, std::function<void(const cli_result_t &)> complete_cb);
|
||||
|
||||
void etcd_txn(json11::Json txn);
|
||||
};
|
||||
|
||||
|
|
|
@ -16,7 +16,6 @@ struct alloc_osd_t
|
|||
uint64_t new_id = 1;
|
||||
|
||||
int state = 0;
|
||||
cli_result_t result;
|
||||
|
||||
bool is_done()
|
||||
{
|
||||
|
@ -63,12 +62,6 @@ struct alloc_osd_t
|
|||
state = 1;
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
if (!parent->etcd_result["succeeded"].bool_value())
|
||||
{
|
||||
std::vector<osd_num_t> used;
|
||||
|
@ -106,15 +99,12 @@ struct alloc_osd_t
|
|||
}
|
||||
} while (!parent->etcd_result["succeeded"].bool_value());
|
||||
state = 100;
|
||||
result = (cli_result_t){
|
||||
.text = std::to_string(new_id),
|
||||
.data = json11::Json(new_id),
|
||||
};
|
||||
}
|
||||
};
|
||||
|
||||
std::function<bool(cli_result_t &)> cli_tool_t::start_alloc_osd(json11::Json cfg)
|
||||
{
|
||||
json11::Json::array cmd = cfg["command"].array_items();
|
||||
auto alloc_osd = new alloc_osd_t();
|
||||
alloc_osd->parent = this;
|
||||
return [alloc_osd](cli_result_t & result)
|
||||
|
@ -122,7 +112,10 @@ std::function<bool(cli_result_t &)> cli_tool_t::start_alloc_osd(json11::Json cfg
|
|||
alloc_osd->loop();
|
||||
if (alloc_osd->is_done())
|
||||
{
|
||||
result = alloc_osd->result;
|
||||
result = (cli_result_t){
|
||||
.text = std::to_string(alloc_osd->new_id),
|
||||
.data = json11::Json(alloc_osd->new_id),
|
||||
};
|
||||
delete alloc_osd;
|
||||
return true;
|
||||
}
|
||||
|
|
|
@ -5,15 +5,13 @@
|
|||
#include "cluster_client.h"
|
||||
#include "cli.h"
|
||||
|
||||
void cli_tool_t::change_parent(inode_t cur, inode_t new_parent, cli_result_t *result)
|
||||
void cli_tool_t::change_parent(inode_t cur, inode_t new_parent)
|
||||
{
|
||||
auto cur_cfg_it = cli->st_cli.inode_config.find(cur);
|
||||
if (cur_cfg_it == cli->st_cli.inode_config.end())
|
||||
{
|
||||
char buf[128];
|
||||
snprintf(buf, 128, "Inode 0x%lx disappeared", cur);
|
||||
*result = (cli_result_t){ .err = EIO, .text = buf };
|
||||
return;
|
||||
fprintf(stderr, "Inode 0x%lx disappeared\n", cur);
|
||||
exit(1);
|
||||
}
|
||||
inode_config_t new_cfg = cur_cfg_it->second;
|
||||
std::string cur_name = new_cfg.name;
|
||||
|
@ -40,33 +38,35 @@ void cli_tool_t::change_parent(inode_t cur, inode_t new_parent, cli_result_t *re
|
|||
} }
|
||||
},
|
||||
} },
|
||||
}, [this, result, new_parent, cur, cur_name](std::string err, json11::Json res)
|
||||
}, [this, new_parent, cur, cur_name](std::string err, json11::Json res)
|
||||
{
|
||||
if (err != "")
|
||||
{
|
||||
*result = (cli_result_t){ .err = EIO, .text = "Error changing parent of "+cur_name+": "+err };
|
||||
fprintf(stderr, "Error changing parent of %s: %s\n", cur_name.c_str(), err.c_str());
|
||||
exit(1);
|
||||
}
|
||||
else if (!res["succeeded"].bool_value())
|
||||
if (!res["succeeded"].bool_value())
|
||||
{
|
||||
*result = (cli_result_t){ .err = EAGAIN, .text = "Image "+cur_name+" was modified during change" };
|
||||
fprintf(stderr, "Inode %s was modified during snapshot deletion\n", cur_name.c_str());
|
||||
exit(1);
|
||||
}
|
||||
else if (new_parent)
|
||||
if (new_parent)
|
||||
{
|
||||
auto new_parent_it = cli->st_cli.inode_config.find(new_parent);
|
||||
std::string new_parent_name = new_parent_it != cli->st_cli.inode_config.end()
|
||||
? new_parent_it->second.name : "<unknown>";
|
||||
*result = (cli_result_t){
|
||||
.text = "Parent of layer "+cur_name+" (inode "+std::to_string(INODE_NO_POOL(cur))+
|
||||
" in pool "+std::to_string(INODE_POOL(cur))+") changed to "+new_parent_name+
|
||||
" (inode "+std::to_string(INODE_NO_POOL(new_parent))+" in pool "+std::to_string(INODE_POOL(new_parent))+")",
|
||||
};
|
||||
printf(
|
||||
"Parent of layer %s (inode %lu in pool %u) changed to %s (inode %lu in pool %u)\n",
|
||||
cur_name.c_str(), INODE_NO_POOL(cur), INODE_POOL(cur),
|
||||
new_parent_name.c_str(), INODE_NO_POOL(new_parent), INODE_POOL(new_parent)
|
||||
);
|
||||
}
|
||||
else
|
||||
{
|
||||
*result = (cli_result_t){
|
||||
.text = "Parent of layer "+cur_name+" (inode "+std::to_string(INODE_NO_POOL(cur))+
|
||||
" in pool "+std::to_string(INODE_POOL(cur))+") detached",
|
||||
};
|
||||
printf(
|
||||
"Parent of layer %s (inode %lu in pool %u) detached\n",
|
||||
cur_name.c_str(), INODE_NO_POOL(cur), INODE_POOL(cur)
|
||||
);
|
||||
}
|
||||
waiting--;
|
||||
ringloop->wakeup();
|
||||
|
@ -80,9 +80,10 @@ void cli_tool_t::etcd_txn(json11::Json txn)
|
|||
{
|
||||
waiting--;
|
||||
if (err != "")
|
||||
etcd_err = (cli_result_t){ .err = EIO, .text = "Error communicating with etcd: "+err };
|
||||
else
|
||||
etcd_err = (cli_result_t){ .err = 0 };
|
||||
{
|
||||
fprintf(stderr, "Error reading from etcd: %s\n", err.c_str());
|
||||
exit(1);
|
||||
}
|
||||
etcd_result = res;
|
||||
ringloop->wakeup();
|
||||
});
|
||||
|
@ -97,7 +98,8 @@ inode_config_t* cli_tool_t::get_inode_cfg(const std::string & name)
|
|||
return &ic.second;
|
||||
}
|
||||
}
|
||||
return NULL;
|
||||
fprintf(stderr, "Layer %s not found\n", name.c_str());
|
||||
exit(1);
|
||||
}
|
||||
|
||||
void cli_tool_t::parse_config(json11::Json cfg)
|
||||
|
@ -114,36 +116,3 @@ void cli_tool_t::parse_config(json11::Json cfg)
|
|||
progress = cfg["progress"].uint64_value() ? true : false;
|
||||
list_first = cfg["wait-list"].uint64_value() ? true : false;
|
||||
}
|
||||
|
||||
struct cli_result_looper_t
|
||||
{
|
||||
ring_consumer_t consumer;
|
||||
cli_result_t result;
|
||||
std::function<bool(cli_result_t &)> loop_cb;
|
||||
std::function<void(const cli_result_t &)> complete_cb;
|
||||
};
|
||||
|
||||
void cli_tool_t::loop_and_wait(std::function<bool(cli_result_t &)> loop_cb, std::function<void(const cli_result_t &)> complete_cb)
|
||||
{
|
||||
auto *looper = new cli_result_looper_t();
|
||||
looper->loop_cb = loop_cb;
|
||||
looper->complete_cb = complete_cb;
|
||||
looper->consumer.loop = [this, looper]()
|
||||
{
|
||||
bool done = looper->loop_cb(looper->result);
|
||||
if (done)
|
||||
{
|
||||
ringloop->unregister_consumer(&looper->consumer);
|
||||
looper->loop_cb = NULL;
|
||||
looper->complete_cb(looper->result);
|
||||
delete looper;
|
||||
return;
|
||||
}
|
||||
ringloop->submit();
|
||||
};
|
||||
cli->on_ready([this, looper]()
|
||||
{
|
||||
ringloop->register_consumer(&looper->consumer);
|
||||
ringloop->wakeup();
|
||||
});
|
||||
}
|
||||
|
|
|
@ -25,15 +25,12 @@ struct image_creator_t
|
|||
pool_id_t new_pool_id = 0;
|
||||
std::string new_pool_name;
|
||||
std::string image_name, new_snap, new_parent;
|
||||
json11::Json new_meta;
|
||||
uint64_t size;
|
||||
bool force_size = false;
|
||||
|
||||
pool_id_t old_pool_id = 0;
|
||||
inode_t new_parent_id = 0;
|
||||
inode_t new_id = 0, old_id = 0;
|
||||
uint64_t max_id_mod_rev = 0, cfg_mod_rev = 0, idx_mod_rev = 0;
|
||||
inode_config_t new_cfg;
|
||||
|
||||
int state = 0;
|
||||
cli_result_t result;
|
||||
|
@ -139,7 +136,7 @@ struct image_creator_t
|
|||
state = 100;
|
||||
return;
|
||||
}
|
||||
if (!size && !force_size)
|
||||
if (!size)
|
||||
{
|
||||
result = (cli_result_t){ .err = EINVAL, .text = "Image size is missing" };
|
||||
state = 100;
|
||||
|
@ -154,24 +151,12 @@ struct image_creator_t
|
|||
resume_2:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
extract_next_id(parent->etcd_result["responses"][0]);
|
||||
attempt_create();
|
||||
state = 3;
|
||||
resume_3:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
if (!parent->etcd_result["succeeded"].bool_value() &&
|
||||
parent->etcd_result["responses"][0]["response_range"]["kvs"].array_items().size() > 0)
|
||||
{
|
||||
|
@ -180,9 +165,6 @@ resume_3:
|
|||
return;
|
||||
}
|
||||
} while (!parent->etcd_result["succeeded"].bool_value());
|
||||
// Save into inode_config for library users to be able to take it from there immediately
|
||||
new_cfg.mod_revision = parent->etcd_result["responses"][0]["response_put"]["header"]["revision"].uint64_value();
|
||||
parent->cli->st_cli.insert_inode_config(new_cfg);
|
||||
result = (cli_result_t){ .err = 0, .text = "Image "+image_name+" created" };
|
||||
state = 100;
|
||||
}
|
||||
|
@ -234,12 +216,6 @@ resume_3:
|
|||
resume_4:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
if (!parent->etcd_result["succeeded"].bool_value() &&
|
||||
parent->etcd_result["responses"][0]["response_range"]["kvs"].array_items().size() > 0)
|
||||
{
|
||||
|
@ -248,9 +224,6 @@ resume_4:
|
|||
return;
|
||||
}
|
||||
} while (!parent->etcd_result["succeeded"].bool_value());
|
||||
// Save into inode_config for library users to be able to take it from there immediately
|
||||
new_cfg.mod_revision = parent->etcd_result["responses"][0]["response_put"]["header"]["revision"].uint64_value();
|
||||
parent->cli->st_cli.insert_inode_config(new_cfg);
|
||||
result = (cli_result_t){ .err = 0, .text = "Snapshot "+image_name+"@"+new_snap+" created" };
|
||||
state = 100;
|
||||
}
|
||||
|
@ -305,12 +278,6 @@ resume_4:
|
|||
resume_2:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
extract_next_id(parent->etcd_result["responses"][0]);
|
||||
old_id = 0;
|
||||
old_pool_id = 0;
|
||||
|
@ -361,12 +328,6 @@ resume_2:
|
|||
resume_3:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
{
|
||||
auto kv = parent->cli->st_cli.parse_etcd_kv(parent->etcd_result["responses"][0]["response_range"]["kvs"][0]);
|
||||
size = kv.value["size"].uint64_value();
|
||||
|
@ -383,13 +344,12 @@ resume_3:
|
|||
|
||||
void attempt_create()
|
||||
{
|
||||
new_cfg = {
|
||||
inode_config_t new_cfg = {
|
||||
.num = INODE_WITH_POOL(new_pool_id, new_id),
|
||||
.name = image_name,
|
||||
.size = size,
|
||||
.parent_id = (new_snap != "" ? INODE_WITH_POOL(old_pool_id, old_id) : new_parent_id),
|
||||
.readonly = false,
|
||||
.meta = new_meta,
|
||||
};
|
||||
json11::Json::array checks = json11::Json::array {
|
||||
json11::Json::object {
|
||||
|
@ -536,20 +496,31 @@ uint64_t parse_size(std::string size_str)
|
|||
|
||||
std::function<bool(cli_result_t &)> cli_tool_t::start_create(json11::Json cfg)
|
||||
{
|
||||
json11::Json::array cmd = cfg["command"].array_items();
|
||||
auto image_creator = new image_creator_t();
|
||||
image_creator->parent = this;
|
||||
image_creator->image_name = cfg["image"].string_value();
|
||||
image_creator->image_name = cmd.size() > 1 ? cmd[1].string_value() : "";
|
||||
image_creator->new_pool_id = cfg["pool"].uint64_value();
|
||||
image_creator->new_pool_name = cfg["pool"].string_value();
|
||||
image_creator->force_size = cfg["force_size"].bool_value();
|
||||
if (cfg["image_meta"].is_object())
|
||||
{
|
||||
image_creator->new_meta = cfg["image-meta"];
|
||||
}
|
||||
if (cfg["snapshot"].string_value() != "")
|
||||
{
|
||||
image_creator->new_snap = cfg["snapshot"].string_value();
|
||||
}
|
||||
else if (cmd[0] == "snap-create")
|
||||
{
|
||||
int p = image_creator->image_name.find('@');
|
||||
if (p == std::string::npos || p == image_creator->image_name.length()-1)
|
||||
{
|
||||
delete image_creator;
|
||||
return [](cli_result_t & result)
|
||||
{
|
||||
result = (cli_result_t){ .err = EINVAL, .text = "Please specify new snapshot name after @" };
|
||||
return true;
|
||||
};
|
||||
}
|
||||
image_creator->new_snap = image_creator->image_name.substr(p + 1);
|
||||
image_creator->image_name = image_creator->image_name.substr(0, p);
|
||||
}
|
||||
image_creator->new_parent = cfg["parent"].string_value();
|
||||
if (cfg["size"].string_value() != "")
|
||||
{
|
||||
|
@ -562,7 +533,7 @@ std::function<bool(cli_result_t &)> cli_tool_t::start_create(json11::Json cfg)
|
|||
return true;
|
||||
};
|
||||
}
|
||||
if ((image_creator->size % 4096) && !cfg["force_size"].bool_value())
|
||||
if (image_creator->size % 4096)
|
||||
{
|
||||
delete image_creator;
|
||||
return [](cli_result_t & result)
|
||||
|
|
|
@ -53,12 +53,6 @@ struct pool_lister_t
|
|||
resume_1:
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (parent->etcd_err.err)
|
||||
{
|
||||
result = parent->etcd_err;
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
space_info = parent->etcd_result;
|
||||
std::map<pool_id_t, uint64_t> osd_free;
|
||||
for (auto & kv_item: space_info["responses"][0]["response_range"]["kvs"].array_items())
|
||||
|
@ -157,12 +151,10 @@ resume_1:
|
|||
get_stats();
|
||||
if (parent->waiting > 0)
|
||||
return;
|
||||
if (state == 100)
|
||||
return;
|
||||
result.data = to_list();
|
||||
if (parent->json_output)
|
||||
{
|
||||
// JSON output
|
||||
result.data = to_list();
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
|
@ -215,7 +207,6 @@ resume_1:
|
|||
: 100)+"%";
|
||||
kv.second["eff_fmt"] = format_q(kv.second["space_efficiency"].number_value()*100)+"%";
|
||||
}
|
||||
result.data = to_list();
|
||||
result.text = print_table(result.data, cols, parent->color);
|
||||
state = 100;
|
||||
}
|
||||
|
@ -223,6 +214,7 @@ resume_1:
|
|||
|
||||
std::function<bool(cli_result_t &)> cli_tool_t::start_df(json11::Json cfg)
|
||||
{
|
||||
json11::Json::array cmd = cfg["command"].array_items();
|
||||
auto lister = new pool_lister_t();
|
||||
lister->parent = this;
|
||||
return [lister](cli_result_t & result)
|
||||
|
|
|
@ -29,12 +29,6 @@ struct snap_flattener_t
|
|||
{
|
||||
// Get all parents of target
|
||||
inode_config_t *target_cfg = parent->get_inode_cfg(target_name);
|
||||
if (!target_cfg)
|
||||
{
|
||||
result = (cli_result_t){ .err = ENOENT, .text = "Layer "+target_name+" not found" };
|
||||
state = 100;
|
||||
return;
|
||||
}
|
||||
target_id = target_cfg->num;
|
||||
std::vector<inode_t> chain_list;
|
||||
inode_config_t *cur = target_cfg;
|
||||
|
@ -94,8 +88,7 @@ struct snap_flattener_t
|
|||
return;
|
||||
// Start merger
|
||||
merger_cb = parent->start_merge(json11::Json::object {
|
||||
{ "from", top_parent_name },
|
||||
{ "to", target_name },
|
||||
{ "command", json11::Json::array{ "merge-data", top_parent_name, target_name } },
|
||||
{ "target", target_name },
|
||||
{ "delete-source", false },
|
||||
{ "cas", use_cas },
|
||||
|
@ -115,7 +108,7 @@ resume_1:
|
|||
return;
|
||||
}
|
||||
// Change parent
|
||||
parent->change_parent(target_id, 0, &result);
|
||||
parent->change_parent(target_id, 0);
|
||||
// Wait for it to complete
|
||||
state = 2;
|
||||
resume_2:
|
||||
|
@ -130,9 +123,10 @@ resume_3:
|
|||
|
||||
std::function<bool(cli_result_t &)> cli_tool_t::start_flatten(json11::Json cfg)
|
||||
{
|
||||
json11::Json::array cmd = cfg["command"].array_items();
|
||||
auto flattener = new snap_flattener_t();
|
||||
flattener->parent = this;
|
||||
flattener->target_name = cfg["image"].string_value();
|
||||
flattener->target_name = cmd.size() > 1 ? cmd[1].string_value() : "";
|
||||
flattener->fsync_interval = cfg["fsync-interval"].uint64_value();
|
||||
if (!flattener->fsync_interval)
|
||||
flattener->fsync_interval = 128;
|
||||
|
|
Some files were not shown because too many files have changed in this diff Show More
Loading…
Reference in New Issue