iscsi: send readcapacity10 when readcapacity16 failed

When play with Dell MD3000 target, for sure it
is a TYPE_DISK, but readcapacity16 would fail.
Then we find that readcapacity10 succeeded. It
looks like the target just support readcapacity10
even through it is a TYPE_DISK or have some
TYPE_ROM characteristics.

This patch can give a chance to send
readcapacity16 when readcapacity10 failed.
This patch is not harmful to original pathes

Signed-off-by: Zhu Lingshan <lszhu@suse.com>
Message-Id: <1451359934-9236-1-git-send-email-lszhu@suse.com>
[Don't fall through on UNIT ATTENTION. - Paolo]
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
master
Zhu Lingshan 2015-12-29 11:32:14 +08:00 committed by Paolo Bonzini
parent 46f296cd3a
commit 1cb6d137ff
1 changed files with 6 additions and 1 deletions

View File

@ -1243,8 +1243,13 @@ static void iscsi_readcapacity_sync(IscsiLun *iscsilun, Error **errp)
iscsilun->lbprz = !!rc16->lbprz;
iscsilun->use_16_for_rw = (rc16->returned_lba > 0xffffffff);
}
break;
}
break;
if (task != NULL && task->status == SCSI_STATUS_CHECK_CONDITION
&& task->sense.key == SCSI_SENSE_UNIT_ATTENTION) {
break;
}
/* Fall through and try READ CAPACITY(10) instead. */
case TYPE_ROM:
task = iscsi_readcapacity10_sync(iscsilun->iscsi, iscsilun->lun, 0, 0);
if (task != NULL && task->status == SCSI_STATUS_GOOD) {