Fix powerpc 604 reset vector

According to 604eUM_book (see 8.3.3 Reset inputs p8-54), the IP bit is set
for hreset and the vector is at offset 0x100 from the exception prefix.

No difference in this area between 604 and 604e.

Signed-off-by: Tristan Gingold <gingold@adacore.com>
master
Tristan Gingold 2009-04-28 18:07:01 +00:00 committed by Blue Swirl
parent fc1c67bc2a
commit 2d3eb7bfd9
1 changed files with 2 additions and 2 deletions

View File

@ -2875,9 +2875,9 @@ static void init_excp_604 (CPUPPCState *env)
env->excp_vectors[POWERPC_EXCP_PERFM] = 0x00000F00;
env->excp_vectors[POWERPC_EXCP_IABR] = 0x00001300;
env->excp_vectors[POWERPC_EXCP_SMI] = 0x00001400;
env->hreset_excp_prefix = 0x00000000UL;
env->hreset_excp_prefix = 0xFFF00000UL;
/* Hardware reset vector */
env->hreset_vector = 0xFFFFFFFCUL;
env->hreset_vector = 0x00000100UL;
#endif
}