s390x: do a subsystem reset before the unprotect on reboot

Bound APQNs have to be reset before tearing down the secure config via
s390_machine_unprotect(). Otherwise the Ultravisor will return a error
code.

So let's do a subsystem_reset() which includes a AP reset before the
unprotect call. We'll do a full device_reset() afterwards which will
reset some devices twice. That's ok since we can't move the
device_reset() before the unprotect as it includes a CPU clear reset
which the Ultravisor does not expect at that point in time.

Signed-off-by: Janosch Frank <frankja@linux.ibm.com>
Message-ID: <20230901114851.154357-1-frankja@linux.ibm.com>
Tested-by: Viktor Mihajlovski <mihajlov@linux.ibm.com>
Acked-by: Christian Borntraeger <borntraeger@linux.ibm.com>
Signed-off-by: Thomas Huth <thuth@redhat.com>
master
Janosch Frank 2023-09-01 11:48:51 +00:00 committed by Thomas Huth
parent 297ec01f0b
commit ef1535901a
1 changed files with 10 additions and 0 deletions

View File

@ -438,10 +438,20 @@ static void s390_machine_reset(MachineState *machine, ShutdownCause reason)
switch (reset_type) {
case S390_RESET_EXTERNAL:
case S390_RESET_REIPL:
/*
* Reset the subsystem which includes a AP reset. If a PV
* guest had APQNs attached the AP reset is a prerequisite to
* unprotecting since the UV checks if all APQNs are reset.
*/
subsystem_reset();
if (s390_is_pv()) {
s390_machine_unprotect(ms);
}
/*
* Device reset includes CPU clear resets so this has to be
* done AFTER the unprotect call above.
*/
qemu_devices_reset(reason);
s390_crypto_reset();