Notes about config and vitastor-disk cache status

epoch-deletions
Vitaliy Filippov 2023-04-29 00:08:24 +03:00
parent 04cfb48361
commit d9c0898b7c
4 changed files with 39 additions and 17 deletions

View File

@ -17,14 +17,16 @@ Configuration parameters can be set in 3 places:
- Configuration file (`/etc/vitastor/vitastor.conf` or other path)
- etcd key `/vitastor/config/global`. Most variables can be set there, but etcd
connection parameters should obviously be set in the configuration file.
- Command line of Vitastor components: OSD, mon, fio and QEMU options,
OpenStack/Proxmox/etc configuration. The latter doesn't allow to set all
variables directly, but it allows to override the configuration file and
set everything you need inside it.
- Command line of Vitastor components: OSD (when you run it without vitastor-disk),
mon, fio and QEMU options, OpenStack/Proxmox/etc configuration. The latter
doesn't allow to set all variables directly, but it allows to override the
configuration file and set everything you need inside it.
- OSD superblocks created by [vitastor-disk](../usage/disk.en.md) contain
primarily disk layout parameters of specific OSDs. In fact, these parameters
are automatically passed into the command line of vitastor-osd process, so
they have the same "status" as command-line parameters.
In the future, additional configuration methods may be added:
- OSD superblock which will, by design, contain parameters related to the disk
layout and to one specific OSD.
- OSD-specific keys in etcd like `/vitastor/config/osd/<number>`.
## Parameter Reference

View File

@ -19,14 +19,17 @@
- Ключе в etcd `/vitastor/config/global`. Большая часть параметров может
задаваться там, кроме, естественно, самих параметров соединения с etcd,
которые должны задаваться в файле конфигурации
- В командной строке компонентов Vitastor: OSD, монитора, опциях fio и QEMU,
настроек OpenStack, Proxmox и т.п. Последние, как правило, не включают полный
набор параметров напрямую, но разрешают определить путь к файлу конфигурации
и задать любые параметры в нём.
- В командной строке компонентов Vitastor: OSD (при ручном запуске без vitastor-disk),
монитора, опциях fio и QEMU, настроек OpenStack, Proxmox и т.п. Последние,
как правило, не включают полный набор параметров напрямую, но позволяют
определить путь к файлу конфигурации и задать любые параметры в нём.
- В суперблоке OSD, записываемом [vitastor-disk](../usage/disk.ru.md) - параметры,
связанные с дисковым форматом и с этим конкретным OSD. На самом деле,
при запуске OSD эти параметры автоматически передаются в командную строку
процесса vitastor-osd, то есть по "статусу" они эквивалентны параметрам
командной строки OSD.
В будущем также могут быть добавлены другие способы конфигурации:
- Суперблок OSD, в котором будут храниться параметры OSD, связанные с дисковым
форматом и с этим конкретным OSD.
- OSD-специфичные ключи в etcd типа `/vitastor/config/osd/<номер>`.
## Список параметров

View File

@ -45,7 +45,9 @@ On the monitor hosts:
}
```
- Initialize OSDs:
- SSD-only: `vitastor-disk prepare /dev/sdXXX [/dev/sdYYY ...]`
- SSD-only: `vitastor-disk prepare /dev/sdXXX [/dev/sdYYY ...]`. You can add
`--disable_data_fsync off` to leave disk cache enabled if you use desktop
SSDs without capacitors.
- Hybrid, SSD+HDD: `vitastor-disk prepare --hybrid /dev/sdXXX [/dev/sdYYY ...]`.
Pass all your devices (HDD and SSD) to this script &mdash; it will partition disks and initialize journals on its own.
This script skips HDDs which are already partitioned so if you want to use non-empty disks for
@ -53,7 +55,9 @@ On the monitor hosts:
but some free unpartitioned space must be available because the script creates new partitions for journals.
- You can change OSD configuration in units or in `vitastor.conf`.
Check [Configuration Reference](../config.en.md) for parameter descriptions.
- If all your drives have capacitors, create global configuration in etcd: \
- If all your drives have capacitors, and even if not, but if you ran `vitastor-disk`
without `--disable_data_fsync off` at the first step, then put the following
setting into etcd: \
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
- Start all OSDs: `systemctl start vitastor.target`
@ -75,6 +79,10 @@ etcdctl --endpoints=... put /vitastor/config/pools '{"2":{"name":"ecpool",
After you do this, one of the monitors will configure PGs and OSDs will start them.
If you use HDDs you should also add `"block_size": 1048576` to pool configuration.
The other option is to add it into /vitastor/config/global, in this case it will
apply to all pools by default.
## Check cluster status
`vitastor-cli status`

View File

@ -45,7 +45,9 @@
}
```
- Инициализуйте OSD:
- SSD: `vitastor-disk prepare /dev/sdXXX [/dev/sdYYY ...]`
- SSD: `vitastor-disk prepare /dev/sdXXX [/dev/sdYYY ...]`. Если вы используете
десктопные SSD без конденсаторов, можете оставить кэш включённым, добавив
опцию `--disable_data_fsync off`.
- Гибридные, SSD+HDD: `vitastor-disk prepare --hybrid /dev/sdXXX [/dev/sdYYY ...]`.
Передайте все ваши SSD и HDD скрипту в командной строке подряд, скрипт автоматически выделит
разделы под журналы на SSD и данные на HDD. Скрипт пропускает HDD, на которых уже есть разделы
@ -54,8 +56,11 @@
для журналов, на SSD должно быть доступно свободное нераспределённое место.
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Описания параметров
смотрите в [справке по конфигурации](../config.ru.md).
- Если все ваши диски - серверные с конденсаторами, пропишите это в глобальную конфигурацию в etcd: \
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
- Если все ваши диски - серверные с конденсаторами, и даже если нет, но при этом
вы не добавляли опцию `--disable_data_fsync off` на первом шаге, а `vitastor-disk`
не ругался на невозможность отключения кэша дисков, пропишите следующую настройку
в глобальную конфигурацию в etcd: \
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`.
- Запустите все OSD: `systemctl start vitastor.target`
## Создайте пул
@ -76,6 +81,10 @@ etcdctl --endpoints=... put /vitastor/config/pools '{"2":{"name":"ecpool",
После этого один из мониторов должен сконфигурировать PG, а OSD должны запустить их.
Если вы используете HDD-диски, то добавьте в конфигурацию пулов опцию `"block_size": 1048576`.
Также эту опцию можно добавить в /vitastor/config/global, в этом случае она будет
применяться ко всем пулам по умолчанию.
## Проверьте состояние кластера
`vitastor-cli status`