Compare commits

...

2 Commits

Author SHA1 Message Date
Vitaliy Filippov 9f52074e1e Delete PG history and stats of deleted pools
Test / test_dd (push) Successful in 11s Details
Test / test_rebalance_verify_ec (push) Successful in 1m38s Details
Test / test_root_node (push) Successful in 10s Details
Test / test_rebalance_verify_ec_imm (push) Successful in 1m40s Details
Test / test_write_no_same (push) Successful in 9s Details
Test / test_switch_primary (push) Successful in 32s Details
Test / test_write (push) Successful in 30s Details
Test / test_write_xor (push) Successful in 34s Details
Test / test_heal_pg_size_2 (push) Successful in 2m13s Details
Test / test_heal_ec (push) Successful in 2m16s Details
Test / test_heal_antietcd (push) Successful in 2m16s Details
Test / test_heal_csum_32k_dmj (push) Successful in 2m18s Details
Test / test_heal_csum_32k_dj (push) Successful in 2m17s Details
Test / test_heal_csum_32k (push) Successful in 2m17s Details
Test / test_heal_csum_4k_dmj (push) Successful in 2m17s Details
Test / test_heal_csum_4k_dj (push) Successful in 2m16s Details
Test / test_osd_tags (push) Successful in 8s Details
Test / test_snapshot_pool2 (push) Successful in 14s Details
Test / test_enospc (push) Successful in 10s Details
Test / test_enospc_xor (push) Successful in 13s Details
Test / test_enospc_imm (push) Successful in 11s Details
Test / test_enospc_imm_xor (push) Successful in 11s Details
Test / test_scrub_zero_osd_2 (push) Successful in 12s Details
Test / test_scrub (push) Successful in 14s Details
Test / test_scrub_xor (push) Successful in 13s Details
Test / test_scrub_pg_size_3 (push) Successful in 15s Details
Test / test_scrub_pg_size_6_pg_minsize_4_osd_count_6_ec (push) Successful in 15s Details
Test / test_scrub_ec (push) Successful in 13s Details
Test / test_nfs (push) Successful in 11s Details
Test / test_heal_csum_4k (push) Successful in 2m17s Details
2024-11-01 02:38:31 +03:00
Vitaliy Filippov 2b3e877546 Add notes about vitastor-disk in disable_data_fsync 2024-11-01 02:38:18 +03:00
4 changed files with 51 additions and 35 deletions

View File

@ -118,12 +118,13 @@ Physical block size of the journal device. Must be a multiple of
- Type: boolean - Type: boolean
- Default: false - Default: false
Do not issue fsyncs to the data device, i.e. do not flush its cache. Do not issue fsyncs to the data device, i.e. do not force it to flush cache.
Safe ONLY if your data device has write-through cache. If you disable Safe ONLY if your data device has write-through cache or if write-back
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure cache is disabled. If you disable drive cache manually with `hdparm` or
that the cache disable command is run every time before starting Vitastor writing to `/sys/.../scsi_disk/cache_type` then make sure that you do it
OSD, for example, in the systemd unit. See also `immediate_commit` option every time before starting Vitastor OSD (vitastor-disk does it automatically).
for the instructions to disable cache and how to benefit from it. See also [immediate_commit](layout-cluster.en.md#immediate_commit)
for information about how to benefit from disabled cache.
## disable_meta_fsync ## disable_meta_fsync
@ -171,8 +172,7 @@ size, it actually has to write the whole 4 KB sector.
Because of this it can actually be beneficial to use SSDs which work well Because of this it can actually be beneficial to use SSDs which work well
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
and meta_block_size. But the only SSD that may fit into this category is and meta_block_size. But at the moment, no such SSDs are known...
Intel Optane (probably, not tested yet).
Clients don't need to be aware of disk_alignment, so it's not required to Clients don't need to be aware of disk_alignment, so it's not required to
put a modified value into etcd key /vitastor/config/global. put a modified value into etcd key /vitastor/config/global.

View File

@ -122,13 +122,14 @@ SSD-диске, иначе производительность пострада
- Тип: булево (да/нет) - Тип: булево (да/нет)
- Значение по умолчанию: false - Значение по умолчанию: false
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш. Не отправлять fsync-и устройству данных, т.е. не заставлять его сбрасывать кэш.
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
записью (write-through). Если вы отключаете кэш через `hdparm` или записью (write-through) или если кэш с отложенной записью (write-back) отключён.
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша Если вы отключаете кэш вручную через `hdparm` или запись в `/sys/.../scsi_disk/cache_type`,
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е. то удостоверьтесь, что вы делаете это каждый раз перед запуском Vitastor OSD
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша (vitastor-disk делает это автоматически). Смотрите также опцию
и о том, как из этого извлечь выгоду. [immediate_commit](layout-cluster.ru.md#immediate_commit) для информации о том,
как извлечь выгоду из отключённого кэша.
## disable_meta_fsync ## disable_meta_fsync
@ -179,9 +180,8 @@ SSD и HDD диски используют 4 КБ физические сект
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment, меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
journal_block_size и meta_block_size. Однако единственные SSD, которые journal_block_size и meta_block_size. Однако на данный момент такие SSD
теоретически могут попасть в эту категорию - это Intel Optane (но и это не известны...
пока не проверялось автором).
Клиентам не обязательно знать про disk_alignment, так что помещать значение Клиентам не обязательно знать про disk_alignment, так что помещать значение
этого параметра в etcd в /vitastor/config/global не нужно. этого параметра в etcd в /vitastor/config/global не нужно.

View File

@ -110,20 +110,22 @@
type: bool type: bool
default: false default: false
info: | info: |
Do not issue fsyncs to the data device, i.e. do not flush its cache. Do not issue fsyncs to the data device, i.e. do not force it to flush cache.
Safe ONLY if your data device has write-through cache. If you disable Safe ONLY if your data device has write-through cache or if write-back
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure cache is disabled. If you disable drive cache manually with `hdparm` or
that the cache disable command is run every time before starting Vitastor writing to `/sys/.../scsi_disk/cache_type` then make sure that you do it
OSD, for example, in the systemd unit. See also `immediate_commit` option every time before starting Vitastor OSD (vitastor-disk does it automatically).
for the instructions to disable cache and how to benefit from it. See also [immediate_commit](layout-cluster.en.md#immediate_commit)
for information about how to benefit from disabled cache.
info_ru: | info_ru: |
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш. Не отправлять fsync-и устройству данных, т.е. не заставлять его сбрасывать кэш.
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
записью (write-through). Если вы отключаете кэш через `hdparm` или записью (write-through) или если кэш с отложенной записью (write-back) отключён.
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша Если вы отключаете кэш вручную через `hdparm` или запись в `/sys/.../scsi_disk/cache_type`,
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е. то удостоверьтесь, что вы делаете это каждый раз перед запуском Vitastor OSD
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша (vitastor-disk делает это автоматически). Смотрите также опцию
и о том, как из этого извлечь выгоду. [immediate_commit](layout-cluster.ru.md#immediate_commit) для информации о том,
как извлечь выгоду из отключённого кэша.
- name: disable_meta_fsync - name: disable_meta_fsync
type: bool type: bool
default: false default: false
@ -179,8 +181,7 @@
Because of this it can actually be beneficial to use SSDs which work well Because of this it can actually be beneficial to use SSDs which work well
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
and meta_block_size. But the only SSD that may fit into this category is and meta_block_size. But at the moment, no such SSDs are known...
Intel Optane (probably, not tested yet).
Clients don't need to be aware of disk_alignment, so it's not required to Clients don't need to be aware of disk_alignment, so it's not required to
put a modified value into etcd key /vitastor/config/global. put a modified value into etcd key /vitastor/config/global.
@ -198,9 +199,8 @@
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment, меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
journal_block_size и meta_block_size. Однако единственные SSD, которые journal_block_size и meta_block_size. Однако на данный момент такие SSD
теоретически могут попасть в эту категорию - это Intel Optane (но и это не известны...
пока не проверялось автором).
Клиентам не обязательно знать про disk_alignment, так что помещать значение Клиентам не обязательно знать про disk_alignment, так что помещать значение
этого параметра в etcd в /vitastor/config/global не нужно. этого параметра в etcd в /vitastor/config/global не нужно.

View File

@ -567,6 +567,7 @@ class Mon
async apply_pool_pgs(results, up_osds, osd_tree, tree_hash) async apply_pool_pgs(results, up_osds, osd_tree, tree_hash)
{ {
const etcd_request = { compare: [], success: [] };
for (const pool_id in (this.state.pg.config||{}).items||{}) for (const pool_id in (this.state.pg.config||{}).items||{})
{ {
// We should stop all PGs when deleting a pool or changing its PG count // We should stop all PGs when deleting a pool or changing its PG count
@ -579,9 +580,24 @@ class Mon
return false; return false;
} }
} }
if (!this.state.config.pools[pool_id])
{
// Delete PG history and stats of the deleted pool
etcd_request.success.push({ requestDeleteRange: {
key: b64(this.config.etcd_prefix+'/pg/history/'+pool_id+'/'),
range_end: b64(this.config.etcd_prefix+'/pg/history/'+pool_id+'0'),
} });
etcd_request.success.push({ requestDeleteRange: {
key: b64(this.config.etcd_prefix+'/pg/stats/'+pool_id+'/'),
range_end: b64(this.config.etcd_prefix+'/pg/stats/'+pool_id+'0'),
} });
etcd_request.success.push({ requestDeleteRange: {
key: b64(this.config.etcd_prefix+'/pgstats/'+pool_id+'/'),
range_end: b64(this.config.etcd_prefix+'/pgstats/'+pool_id+'0'),
} });
}
} }
const new_pg_config = JSON.parse(JSON.stringify(this.state.pg.config)); const new_pg_config = JSON.parse(JSON.stringify(this.state.pg.config));
const etcd_request = { compare: [], success: [] };
for (const pool_id in (new_pg_config||{}).items||{}) for (const pool_id in (new_pg_config||{}).items||{})
{ {
if (!this.state.config.pools[pool_id]) if (!this.state.config.pools[pool_id])