Compare commits
1 Commits
Author | SHA1 | Date |
---|---|---|
Vitaliy Filippov | d23a8a83e5 |
|
@ -22,7 +22,7 @@ RUN apt-get update
|
||||||
RUN apt-get -y install etcd qemu-system-x86 qemu-block-extra qemu-utils fio libasan5 \
|
RUN apt-get -y install etcd qemu-system-x86 qemu-block-extra qemu-utils fio libasan5 \
|
||||||
liburing1 liburing-dev libgoogle-perftools-dev devscripts libjerasure-dev cmake libibverbs-dev libisal-dev
|
liburing1 liburing-dev libgoogle-perftools-dev devscripts libjerasure-dev cmake libibverbs-dev libisal-dev
|
||||||
RUN apt-get -y build-dep fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
|
RUN apt-get -y build-dep fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
|
||||||
RUN apt-get update && apt-get -y install jq lp-solve sudo nfs-common fdisk parted
|
RUN apt-get -y install jq lp-solve sudo nfs-common
|
||||||
RUN apt-get --download-only source fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
|
RUN apt-get --download-only source fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
|
||||||
|
|
||||||
RUN set -ex; \
|
RUN set -ex; \
|
||||||
|
|
|
@ -16,7 +16,6 @@ env:
|
||||||
BUILDENV_IMAGE: git.yourcmc.ru/vitalif/vitastor/buildenv
|
BUILDENV_IMAGE: git.yourcmc.ru/vitalif/vitastor/buildenv
|
||||||
TEST_IMAGE: git.yourcmc.ru/vitalif/vitastor/test
|
TEST_IMAGE: git.yourcmc.ru/vitalif/vitastor/test
|
||||||
OSD_ARGS: '--etcd_quick_timeout 2000'
|
OSD_ARGS: '--etcd_quick_timeout 2000'
|
||||||
USE_RAMDISK: 1
|
|
||||||
|
|
||||||
concurrency:
|
concurrency:
|
||||||
group: ci-${{ github.ref }}
|
group: ci-${{ github.ref }}
|
||||||
|
@ -198,24 +197,6 @@ jobs:
|
||||||
echo ""
|
echo ""
|
||||||
done
|
done
|
||||||
|
|
||||||
test_etcd_fail_antietcd:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 10
|
|
||||||
run: ANTIETCD=1 /root/vitastor/tests/test_etcd_fail.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_interrupted_rebalance:
|
test_interrupted_rebalance:
|
||||||
runs-on: ubuntu-latest
|
runs-on: ubuntu-latest
|
||||||
needs: build
|
needs: build
|
||||||
|
@ -288,24 +269,6 @@ jobs:
|
||||||
echo ""
|
echo ""
|
||||||
done
|
done
|
||||||
|
|
||||||
test_create_halfhost:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 3
|
|
||||||
run: /root/vitastor/tests/test_create_halfhost.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_failure_domain:
|
test_failure_domain:
|
||||||
runs-on: ubuntu-latest
|
runs-on: ubuntu-latest
|
||||||
needs: build
|
needs: build
|
||||||
|
@ -576,24 +539,6 @@ jobs:
|
||||||
echo ""
|
echo ""
|
||||||
done
|
done
|
||||||
|
|
||||||
test_dd:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 3
|
|
||||||
run: /root/vitastor/tests/test_dd.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_root_node:
|
test_root_node:
|
||||||
runs-on: ubuntu-latest
|
runs-on: ubuntu-latest
|
||||||
needs: build
|
needs: build
|
||||||
|
@ -720,24 +665,6 @@ jobs:
|
||||||
echo ""
|
echo ""
|
||||||
done
|
done
|
||||||
|
|
||||||
test_heal_antietcd:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 10
|
|
||||||
run: ANTIETCD=1 /root/vitastor/tests/test_heal.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_heal_csum_32k_dmj:
|
test_heal_csum_32k_dmj:
|
||||||
runs-on: ubuntu-latest
|
runs-on: ubuntu-latest
|
||||||
needs: build
|
needs: build
|
||||||
|
@ -846,60 +773,6 @@ jobs:
|
||||||
echo ""
|
echo ""
|
||||||
done
|
done
|
||||||
|
|
||||||
test_resize:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 3
|
|
||||||
run: /root/vitastor/tests/test_resize.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_resize_auto:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 3
|
|
||||||
run: /root/vitastor/tests/test_resize_auto.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_snapshot_pool2:
|
|
||||||
runs-on: ubuntu-latest
|
|
||||||
needs: build
|
|
||||||
container: ${{env.TEST_IMAGE}}:${{github.sha}}
|
|
||||||
steps:
|
|
||||||
- name: Run test
|
|
||||||
id: test
|
|
||||||
timeout-minutes: 3
|
|
||||||
run: /root/vitastor/tests/test_snapshot_pool2.sh
|
|
||||||
- name: Print logs
|
|
||||||
if: always() && steps.test.outcome == 'failure'
|
|
||||||
run: |
|
|
||||||
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
|
|
||||||
echo "-------- $i --------"
|
|
||||||
cat $i
|
|
||||||
echo ""
|
|
||||||
done
|
|
||||||
|
|
||||||
test_osd_tags:
|
test_osd_tags:
|
||||||
runs-on: ubuntu-latest
|
runs-on: ubuntu-latest
|
||||||
needs: build
|
needs: build
|
||||||
|
|
|
@ -34,10 +34,6 @@ for my $line (<>)
|
||||||
{
|
{
|
||||||
$test_name .= '_imm';
|
$test_name .= '_imm';
|
||||||
}
|
}
|
||||||
elsif ($1 eq 'ANTIETCD')
|
|
||||||
{
|
|
||||||
$test_name .= '_antietcd';
|
|
||||||
}
|
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
$test_name .= '_'.lc($1).'_'.$2;
|
$test_name .= '_'.lc($1).'_'.$2;
|
||||||
|
|
|
@ -2,6 +2,6 @@ cmake_minimum_required(VERSION 2.8.12)
|
||||||
|
|
||||||
project(vitastor)
|
project(vitastor)
|
||||||
|
|
||||||
set(VITASTOR_VERSION "1.10.0")
|
set(VERSION "1.6.1")
|
||||||
|
|
||||||
add_subdirectory(src)
|
add_subdirectory(src)
|
||||||
|
|
|
@ -1,4 +1,4 @@
|
||||||
# Vitastor
|
## Vitastor
|
||||||
|
|
||||||
[Read English version](README.md)
|
[Read English version](README.md)
|
||||||
|
|
||||||
|
@ -19,10 +19,10 @@ Vitastor нацелен в первую очередь на SSD и SSD+HDD кл
|
||||||
TCP и RDMA и на хорошем железе может достигать задержки 4 КБ чтения и записи на уровне ~0.1 мс,
|
TCP и RDMA и на хорошем железе может достигать задержки 4 КБ чтения и записи на уровне ~0.1 мс,
|
||||||
что примерно в 10 раз быстрее, чем Ceph и другие популярные программные СХД.
|
что примерно в 10 раз быстрее, чем Ceph и другие популярные программные СХД.
|
||||||
|
|
||||||
Vitastor поддерживает QEMU-драйвер, протоколы NBD и NFS, драйверы OpenStack, OpenNebula, Proxmox, Kubernetes.
|
Vitastor поддерживает QEMU-драйвер, протоколы NBD и NFS, драйверы OpenStack, Proxmox, Kubernetes.
|
||||||
Другие драйверы могут также быть легко реализованы.
|
Другие драйверы могут также быть легко реализованы.
|
||||||
|
|
||||||
Подробности смотрите в документации по ссылкам. Можете начать отсюда: [Быстрый старт](docs/intro/quickstart.ru.md).
|
Подробности смотрите в документации по ссылкам ниже.
|
||||||
|
|
||||||
## Презентации и записи докладов
|
## Презентации и записи докладов
|
||||||
|
|
||||||
|
@ -42,7 +42,6 @@ Vitastor поддерживает QEMU-драйвер, протоколы NBD и
|
||||||
- Установка
|
- Установка
|
||||||
- [Пакеты](docs/installation/packages.ru.md)
|
- [Пакеты](docs/installation/packages.ru.md)
|
||||||
- [Proxmox](docs/installation/proxmox.ru.md)
|
- [Proxmox](docs/installation/proxmox.ru.md)
|
||||||
- [OpenNebula](docs/installation/opennebula.ru.md)
|
|
||||||
- [OpenStack](docs/installation/openstack.ru.md)
|
- [OpenStack](docs/installation/openstack.ru.md)
|
||||||
- [Kubernetes CSI](docs/installation/kubernetes.ru.md)
|
- [Kubernetes CSI](docs/installation/kubernetes.ru.md)
|
||||||
- [Сборка из исходных кодов](docs/installation/source.ru.md)
|
- [Сборка из исходных кодов](docs/installation/source.ru.md)
|
||||||
|
@ -51,7 +50,7 @@ Vitastor поддерживает QEMU-драйвер, протоколы NBD и
|
||||||
- Параметры
|
- Параметры
|
||||||
- [Общие](docs/config/common.ru.md)
|
- [Общие](docs/config/common.ru.md)
|
||||||
- [Сетевые](docs/config/network.ru.md)
|
- [Сетевые](docs/config/network.ru.md)
|
||||||
- [Клиентский код](docs/config/client.ru.md)
|
- [Клиентский код](docs/config/client.en.md)
|
||||||
- [Глобальные дисковые параметры](docs/config/layout-cluster.ru.md)
|
- [Глобальные дисковые параметры](docs/config/layout-cluster.ru.md)
|
||||||
- [Дисковые параметры OSD](docs/config/layout-osd.ru.md)
|
- [Дисковые параметры OSD](docs/config/layout-osd.ru.md)
|
||||||
- [Прочие параметры OSD](docs/config/osd.ru.md)
|
- [Прочие параметры OSD](docs/config/osd.ru.md)
|
||||||
|
|
|
@ -19,10 +19,10 @@ supports TCP and RDMA and may achieve 4 KB read and write latency as low as ~0.1
|
||||||
with proper hardware which is ~10 times faster than other popular SDS's like Ceph
|
with proper hardware which is ~10 times faster than other popular SDS's like Ceph
|
||||||
or internal systems of public clouds.
|
or internal systems of public clouds.
|
||||||
|
|
||||||
Vitastor supports QEMU, NBD, NFS protocols, OpenStack, OpenNebula, Proxmox, Kubernetes drivers.
|
Vitastor supports QEMU, NBD, NFS protocols, OpenStack, Proxmox, Kubernetes drivers.
|
||||||
More drivers may be created easily.
|
More drivers may be created easily.
|
||||||
|
|
||||||
Read more details in the documentation. You can start from here: [Quick Start](docs/intro/quickstart.en.md).
|
Read more details below in the documentation.
|
||||||
|
|
||||||
## Talks and presentations
|
## Talks and presentations
|
||||||
|
|
||||||
|
@ -42,7 +42,6 @@ Read more details in the documentation. You can start from here: [Quick Start](d
|
||||||
- Installation
|
- Installation
|
||||||
- [Packages](docs/installation/packages.en.md)
|
- [Packages](docs/installation/packages.en.md)
|
||||||
- [Proxmox](docs/installation/proxmox.en.md)
|
- [Proxmox](docs/installation/proxmox.en.md)
|
||||||
- [OpenNebula](docs/installation/opennebula.en.md)
|
|
||||||
- [OpenStack](docs/installation/openstack.en.md)
|
- [OpenStack](docs/installation/openstack.en.md)
|
||||||
- [Kubernetes CSI](docs/installation/kubernetes.en.md)
|
- [Kubernetes CSI](docs/installation/kubernetes.en.md)
|
||||||
- [Building from Source](docs/installation/source.en.md)
|
- [Building from Source](docs/installation/source.en.md)
|
||||||
|
|
|
@ -22,8 +22,6 @@ RUN apt-get update && \
|
||||||
(echo "APT::Install-Recommends false;" > /etc/apt/apt.conf) && \
|
(echo "APT::Install-Recommends false;" > /etc/apt/apt.conf) && \
|
||||||
apt-get update && \
|
apt-get update && \
|
||||||
apt-get install -y e2fsprogs xfsprogs kmod iproute2 \
|
apt-get install -y e2fsprogs xfsprogs kmod iproute2 \
|
||||||
# NFS mount dependencies
|
|
||||||
nfs-common netbase \
|
|
||||||
# dependencies of qemu-storage-daemon
|
# dependencies of qemu-storage-daemon
|
||||||
libnuma1 liburing2 libglib2.0-0 libfuse3-3 libaio1 libzstd1 libnettle8 \
|
libnuma1 liburing2 libglib2.0-0 libfuse3-3 libaio1 libzstd1 libnettle8 \
|
||||||
libgmp10 libhogweed6 libp11-kit0 libidn2-0 libunistring2 libtasn1-6 libpcre2-8-0 libffi8 && \
|
libgmp10 libhogweed6 libp11-kit0 libidn2-0 libunistring2 libtasn1-6 libpcre2-8-0 libffi8 && \
|
||||||
|
|
|
@ -1,9 +1,9 @@
|
||||||
VITASTOR_VERSION ?= v1.10.0
|
VERSION ?= v1.6.1
|
||||||
|
|
||||||
all: build push
|
all: build push
|
||||||
|
|
||||||
build:
|
build:
|
||||||
@docker build --rm -t vitalif/vitastor-csi:$(VITASTOR_VERSION) .
|
@docker build --rm -t vitalif/vitastor-csi:$(VERSION) .
|
||||||
|
|
||||||
push:
|
push:
|
||||||
@docker push vitalif/vitastor-csi:$(VITASTOR_VERSION)
|
@docker push vitalif/vitastor-csi:$(VERSION)
|
||||||
|
|
|
@ -49,7 +49,7 @@ spec:
|
||||||
capabilities:
|
capabilities:
|
||||||
add: ["SYS_ADMIN"]
|
add: ["SYS_ADMIN"]
|
||||||
allowPrivilegeEscalation: true
|
allowPrivilegeEscalation: true
|
||||||
image: vitalif/vitastor-csi:v1.10.0
|
image: vitalif/vitastor-csi:v1.6.1
|
||||||
args:
|
args:
|
||||||
- "--node=$(NODE_ID)"
|
- "--node=$(NODE_ID)"
|
||||||
- "--endpoint=$(CSI_ENDPOINT)"
|
- "--endpoint=$(CSI_ENDPOINT)"
|
||||||
|
|
|
@ -121,7 +121,7 @@ spec:
|
||||||
privileged: true
|
privileged: true
|
||||||
capabilities:
|
capabilities:
|
||||||
add: ["SYS_ADMIN"]
|
add: ["SYS_ADMIN"]
|
||||||
image: vitalif/vitastor-csi:v1.10.0
|
image: vitalif/vitastor-csi:v1.6.1
|
||||||
args:
|
args:
|
||||||
- "--node=$(NODE_ID)"
|
- "--node=$(NODE_ID)"
|
||||||
- "--endpoint=$(CSI_ENDPOINT)"
|
- "--endpoint=$(CSI_ENDPOINT)"
|
||||||
|
|
|
@ -9,16 +9,8 @@ metadata:
|
||||||
provisioner: csi.vitastor.io
|
provisioner: csi.vitastor.io
|
||||||
volumeBindingMode: Immediate
|
volumeBindingMode: Immediate
|
||||||
parameters:
|
parameters:
|
||||||
# CSI driver can create block-based volumes and VitastorFS-based volumes
|
etcdVolumePrefix: ""
|
||||||
# only VitastorFS-based volumes and raw block volumes (without FS) support ReadWriteMany mode
|
poolId: "1"
|
||||||
# set this parameter to VitastorFS metadata volume name to use VitastorFS
|
|
||||||
# if unset, block-based volumes will be created
|
|
||||||
vitastorfs: ""
|
|
||||||
# for block-based storage classes, pool ID may be either a string (name) or a number (ID)
|
|
||||||
# for vitastorFS-based storage classes it must be a string - name of the default pool for FS data
|
|
||||||
poolId: "testpool"
|
|
||||||
# volume name prefix for block-based storage classes or NFS subdirectory (including /) for FS-based volumes
|
|
||||||
volumePrefix: ""
|
|
||||||
# you can choose other configuration file if you have it in the config map
|
# you can choose other configuration file if you have it in the config map
|
||||||
# different etcd URLs and prefixes should also be put in the config
|
# different etcd URLs and prefixes should also be put in the config
|
||||||
#configPath: "/etc/vitastor/vitastor.conf"
|
#configPath: "/etc/vitastor/vitastor.conf"
|
||||||
|
|
|
@ -1,25 +0,0 @@
|
||||||
---
|
|
||||||
apiVersion: storage.k8s.io/v1
|
|
||||||
kind: StorageClass
|
|
||||||
metadata:
|
|
||||||
namespace: vitastor-system
|
|
||||||
name: vitastor
|
|
||||||
annotations:
|
|
||||||
storageclass.kubernetes.io/is-default-class: "true"
|
|
||||||
provisioner: csi.vitastor.io
|
|
||||||
volumeBindingMode: Immediate
|
|
||||||
parameters:
|
|
||||||
# CSI driver can create block-based volumes and VitastorFS-based volumes
|
|
||||||
# only VitastorFS-based volumes and raw block volumes (without FS) support ReadWriteMany mode
|
|
||||||
# set this parameter to VitastorFS metadata volume name to use VitastorFS
|
|
||||||
# if unset, block-based volumes will be created
|
|
||||||
vitastorfs: "testfs"
|
|
||||||
# for block-based storage classes, pool ID may be either a string (name) or a number (ID)
|
|
||||||
# for vitastorFS-based storage classes it must be a string - name of the default pool for FS data
|
|
||||||
poolId: "testpool"
|
|
||||||
# volume name prefix for block-based storage classes or NFS subdirectory (including /) for FS-based volumes
|
|
||||||
volumePrefix: "k8s/"
|
|
||||||
# you can choose other configuration file if you have it in the config map
|
|
||||||
# different etcd URLs and prefixes should also be put in the config
|
|
||||||
#configPath: "/etc/vitastor/vitastor.conf"
|
|
||||||
allowVolumeExpansion: true
|
|
|
@ -3,10 +3,10 @@ module vitastor.io/csi
|
||||||
go 1.15
|
go 1.15
|
||||||
|
|
||||||
require (
|
require (
|
||||||
github.com/container-storage-interface/spec v1.8.0
|
github.com/container-storage-interface/spec v1.4.0
|
||||||
github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b
|
github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b
|
||||||
github.com/kubernetes-csi/csi-lib-utils v0.9.1
|
github.com/kubernetes-csi/csi-lib-utils v0.9.1
|
||||||
golang.org/x/net v0.7.0
|
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb
|
||||||
golang.org/x/xerrors v0.0.0-20200804184101-5ec99f83aff1 // indirect
|
golang.org/x/xerrors v0.0.0-20200804184101-5ec99f83aff1 // indirect
|
||||||
google.golang.org/grpc v1.33.1
|
google.golang.org/grpc v1.33.1
|
||||||
google.golang.org/protobuf v1.24.0
|
google.golang.org/protobuf v1.24.0
|
||||||
|
|
31
csi/go.sum
31
csi/go.sum
|
@ -41,8 +41,8 @@ github.com/chzyer/logex v1.1.10/go.mod h1:+Ywpsq7O8HXn0nuIou7OrIPyXbp3wmkHB+jjWR
|
||||||
github.com/chzyer/readline v0.0.0-20180603132655-2972be24d48e/go.mod h1:nSuG5e5PlCu98SY8svDHJxuZscDgtXS6KTTbou5AhLI=
|
github.com/chzyer/readline v0.0.0-20180603132655-2972be24d48e/go.mod h1:nSuG5e5PlCu98SY8svDHJxuZscDgtXS6KTTbou5AhLI=
|
||||||
github.com/chzyer/test v0.0.0-20180213035817-a1ea475d72b1/go.mod h1:Q3SI9o4m/ZMnBNeIyt5eFwwo7qiLfzFZmjNmxjkiQlU=
|
github.com/chzyer/test v0.0.0-20180213035817-a1ea475d72b1/go.mod h1:Q3SI9o4m/ZMnBNeIyt5eFwwo7qiLfzFZmjNmxjkiQlU=
|
||||||
github.com/container-storage-interface/spec v1.2.0/go.mod h1:6URME8mwIBbpVyZV93Ce5St17xBiQJQY67NDsuohiy4=
|
github.com/container-storage-interface/spec v1.2.0/go.mod h1:6URME8mwIBbpVyZV93Ce5St17xBiQJQY67NDsuohiy4=
|
||||||
github.com/container-storage-interface/spec v1.8.0 h1:D0vhF3PLIZwlwZEf2eNbpujGCNwspwTYf2idJRJx4xI=
|
github.com/container-storage-interface/spec v1.4.0 h1:ozAshSKxpJnYUfmkpZCTYyF/4MYeYlhdXbAvPvfGmkg=
|
||||||
github.com/container-storage-interface/spec v1.8.0/go.mod h1:ROLik+GhPslwwWRNFF1KasPzroNARibH2rfz1rkg4H0=
|
github.com/container-storage-interface/spec v1.4.0/go.mod h1:6URME8mwIBbpVyZV93Ce5St17xBiQJQY67NDsuohiy4=
|
||||||
github.com/davecgh/go-spew v1.1.0/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
|
github.com/davecgh/go-spew v1.1.0/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
|
||||||
github.com/davecgh/go-spew v1.1.1 h1:vj9j/u1bqnvCEfJOwUhtlOARqs3+rkHYY13jYWTU97c=
|
github.com/davecgh/go-spew v1.1.1 h1:vj9j/u1bqnvCEfJOwUhtlOARqs3+rkHYY13jYWTU97c=
|
||||||
github.com/davecgh/go-spew v1.1.1/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
|
github.com/davecgh/go-spew v1.1.1/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
|
||||||
|
@ -182,7 +182,6 @@ github.com/stretchr/testify v1.3.0/go.mod h1:M5WIy9Dh21IEIfnGCwXGc5bZfKNJtfHm1UV
|
||||||
github.com/stretchr/testify v1.4.0/go.mod h1:j7eGeouHqKxXV5pUuKE4zz7dFj8WfuZ+81PSLYec5m4=
|
github.com/stretchr/testify v1.4.0/go.mod h1:j7eGeouHqKxXV5pUuKE4zz7dFj8WfuZ+81PSLYec5m4=
|
||||||
github.com/stretchr/testify v1.5.1 h1:nOGnQDM7FYENwehXlg/kFVnos3rEvtKTjRvOWSzb6H4=
|
github.com/stretchr/testify v1.5.1 h1:nOGnQDM7FYENwehXlg/kFVnos3rEvtKTjRvOWSzb6H4=
|
||||||
github.com/stretchr/testify v1.5.1/go.mod h1:5W2xD1RspED5o8YsWQXVCued0rvSQ+mT+I5cxcmMvtA=
|
github.com/stretchr/testify v1.5.1/go.mod h1:5W2xD1RspED5o8YsWQXVCued0rvSQ+mT+I5cxcmMvtA=
|
||||||
github.com/yuin/goldmark v1.4.13/go.mod h1:6yULJ656Px+3vBD8DxQVa3kxgyrAnzto9xy5taEt/CY=
|
|
||||||
go.opencensus.io v0.21.0/go.mod h1:mSImk1erAIZhrmZN+AvHh14ztQfjbGwt4TtuofqLduU=
|
go.opencensus.io v0.21.0/go.mod h1:mSImk1erAIZhrmZN+AvHh14ztQfjbGwt4TtuofqLduU=
|
||||||
go.opencensus.io v0.22.0/go.mod h1:+kGneAE2xo2IficOXnaByMWTGM9T73dGwxeWcUqIpI8=
|
go.opencensus.io v0.22.0/go.mod h1:+kGneAE2xo2IficOXnaByMWTGM9T73dGwxeWcUqIpI8=
|
||||||
go.opencensus.io v0.22.2/go.mod h1:yxeiOL68Rb0Xd1ddK5vPZ/oVn4vY4Ynel7k9FzqtOIw=
|
go.opencensus.io v0.22.2/go.mod h1:yxeiOL68Rb0Xd1ddK5vPZ/oVn4vY4Ynel7k9FzqtOIw=
|
||||||
|
@ -196,7 +195,6 @@ golang.org/x/crypto v0.0.0-20190605123033-f99c8df09eb5/go.mod h1:yigFU9vqHzYiE8U
|
||||||
golang.org/x/crypto v0.0.0-20191011191535-87dc89f01550/go.mod h1:yigFU9vqHzYiE8UmvKecakEJjdnWj3jj499lnFckfCI=
|
golang.org/x/crypto v0.0.0-20191011191535-87dc89f01550/go.mod h1:yigFU9vqHzYiE8UmvKecakEJjdnWj3jj499lnFckfCI=
|
||||||
golang.org/x/crypto v0.0.0-20191206172530-e9b2fee46413/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
|
golang.org/x/crypto v0.0.0-20191206172530-e9b2fee46413/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
|
||||||
golang.org/x/crypto v0.0.0-20200622213623-75b288015ac9/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
|
golang.org/x/crypto v0.0.0-20200622213623-75b288015ac9/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
|
||||||
golang.org/x/crypto v0.0.0-20210921155107-089bfa567519/go.mod h1:GvvjBRRGRdwPK5ydBHafDWAxML/pGHZbMvKqRZ5+Abc=
|
|
||||||
golang.org/x/exp v0.0.0-20190121172915-509febef88a4/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
|
golang.org/x/exp v0.0.0-20190121172915-509febef88a4/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
|
||||||
golang.org/x/exp v0.0.0-20190306152737-a1d7652674e8/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
|
golang.org/x/exp v0.0.0-20190306152737-a1d7652674e8/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
|
||||||
golang.org/x/exp v0.0.0-20190510132918-efd6b22b2522/go.mod h1:ZjyILWgesfNpC6sMxTJOJm9Kp84zZh5NQWvqDGG3Qr8=
|
golang.org/x/exp v0.0.0-20190510132918-efd6b22b2522/go.mod h1:ZjyILWgesfNpC6sMxTJOJm9Kp84zZh5NQWvqDGG3Qr8=
|
||||||
|
@ -215,7 +213,6 @@ golang.org/x/mobile v0.0.0-20190719004257-d2bd2a29d028/go.mod h1:E/iHnbuqvinMTCc
|
||||||
golang.org/x/mod v0.0.0-20190513183733-4bf6d317e70e/go.mod h1:mXi4GBBbnImb6dmsKGUJ2LatrhH/nqhxcFungHvyanc=
|
golang.org/x/mod v0.0.0-20190513183733-4bf6d317e70e/go.mod h1:mXi4GBBbnImb6dmsKGUJ2LatrhH/nqhxcFungHvyanc=
|
||||||
golang.org/x/mod v0.1.0/go.mod h1:0QHyrYULN0/3qlju5TqG8bIK38QM8yzMo5ekMj3DlcY=
|
golang.org/x/mod v0.1.0/go.mod h1:0QHyrYULN0/3qlju5TqG8bIK38QM8yzMo5ekMj3DlcY=
|
||||||
golang.org/x/mod v0.1.1-0.20191105210325-c90efee705ee/go.mod h1:QqPTAvyqsEbceGzBzNggFXnrqF1CaUcvgkdR5Ot7KZg=
|
golang.org/x/mod v0.1.1-0.20191105210325-c90efee705ee/go.mod h1:QqPTAvyqsEbceGzBzNggFXnrqF1CaUcvgkdR5Ot7KZg=
|
||||||
golang.org/x/mod v0.6.0-dev.0.20220419223038-86c51ed26bb4/go.mod h1:jJ57K6gSWd91VN4djpZkiMVwK6gcyfeH4XE8wZrZaV4=
|
|
||||||
golang.org/x/net v0.0.0-20180724234803-3673e40ba225/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
golang.org/x/net v0.0.0-20180724234803-3673e40ba225/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
||||||
golang.org/x/net v0.0.0-20180906233101-161cd47e91fd/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
golang.org/x/net v0.0.0-20180906233101-161cd47e91fd/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
||||||
golang.org/x/net v0.0.0-20181114220301-adae6a3d119a/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
golang.org/x/net v0.0.0-20181114220301-adae6a3d119a/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
|
||||||
|
@ -231,10 +228,8 @@ golang.org/x/net v0.0.0-20190620200207-3b0461eec859/go.mod h1:z5CRVTTTmAJ677TzLL
|
||||||
golang.org/x/net v0.0.0-20191209160850-c0dbc17a3553/go.mod h1:z5CRVTTTmAJ677TzLLGU+0bjPO0LkuOLi4/5GtJWs/s=
|
golang.org/x/net v0.0.0-20191209160850-c0dbc17a3553/go.mod h1:z5CRVTTTmAJ677TzLLGU+0bjPO0LkuOLi4/5GtJWs/s=
|
||||||
golang.org/x/net v0.0.0-20200324143707-d3edc9973b7e/go.mod h1:qpuaurCH72eLCgpAm/N6yyVIVM9cpaDIP3A8BGJEC5A=
|
golang.org/x/net v0.0.0-20200324143707-d3edc9973b7e/go.mod h1:qpuaurCH72eLCgpAm/N6yyVIVM9cpaDIP3A8BGJEC5A=
|
||||||
golang.org/x/net v0.0.0-20200707034311-ab3426394381/go.mod h1:/O7V0waA8r7cgGh81Ro3o1hOxt32SMVPicZroKQ2sZA=
|
golang.org/x/net v0.0.0-20200707034311-ab3426394381/go.mod h1:/O7V0waA8r7cgGh81Ro3o1hOxt32SMVPicZroKQ2sZA=
|
||||||
golang.org/x/net v0.0.0-20210226172049-e18ecbb05110/go.mod h1:m0MpNAwzfU5UDzcl9v0D8zg8gWTRqZa9RBIspLL5mdg=
|
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb h1:eBmm0M9fYhWpKZLjQUUKka/LtIxf46G4fxeEz5KJr9U=
|
||||||
golang.org/x/net v0.0.0-20220722155237-a158d28d115b/go.mod h1:XRhObCWvk6IyKnWLug+ECip1KBveYUHfp+8e9klMJ9c=
|
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb/go.mod h1:sp8m0HH+o8qH0wwXwYZr8TS3Oi6o0r6Gce1SSxlDquU=
|
||||||
golang.org/x/net v0.7.0 h1:rJrUqqhjsgNp7KqAIc25s9pZnjU7TUcSY7HcVZjdn1g=
|
|
||||||
golang.org/x/net v0.7.0/go.mod h1:2Tu9+aMcznHK/AK1HMvgo6xiTLG5rD5rZLDS+rp2Bjs=
|
|
||||||
golang.org/x/oauth2 v0.0.0-20180821212333-d2e6202438be/go.mod h1:N/0e6XlmueqKjAGxoOufVs8QHGRruUQn6yWY3a++T0U=
|
golang.org/x/oauth2 v0.0.0-20180821212333-d2e6202438be/go.mod h1:N/0e6XlmueqKjAGxoOufVs8QHGRruUQn6yWY3a++T0U=
|
||||||
golang.org/x/oauth2 v0.0.0-20190226205417-e64efc72b421/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
|
golang.org/x/oauth2 v0.0.0-20190226205417-e64efc72b421/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
|
||||||
golang.org/x/oauth2 v0.0.0-20190604053449-0f29369cfe45/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
|
golang.org/x/oauth2 v0.0.0-20190604053449-0f29369cfe45/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
|
||||||
|
@ -245,7 +240,6 @@ golang.org/x/sync v0.0.0-20181221193216-37e7f081c4d4/go.mod h1:RxMgew5VJxzue5/jJ
|
||||||
golang.org/x/sync v0.0.0-20190227155943-e225da77a7e6/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
golang.org/x/sync v0.0.0-20190227155943-e225da77a7e6/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
||||||
golang.org/x/sync v0.0.0-20190423024810-112230192c58/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
golang.org/x/sync v0.0.0-20190423024810-112230192c58/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
||||||
golang.org/x/sync v0.0.0-20190911185100-cd5d95a43a6e/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
golang.org/x/sync v0.0.0-20190911185100-cd5d95a43a6e/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
||||||
golang.org/x/sync v0.0.0-20220722155255-886fb9371eb4/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
|
|
||||||
golang.org/x/sys v0.0.0-20180905080454-ebe1bf3edb33/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
golang.org/x/sys v0.0.0-20180905080454-ebe1bf3edb33/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
||||||
golang.org/x/sys v0.0.0-20180909124046-d0be0721c37e/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
golang.org/x/sys v0.0.0-20180909124046-d0be0721c37e/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
||||||
golang.org/x/sys v0.0.0-20181116152217-5ac8a444bdc5/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
golang.org/x/sys v0.0.0-20181116152217-5ac8a444bdc5/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
|
||||||
|
@ -265,22 +259,13 @@ golang.org/x/sys v0.0.0-20200302150141-5c8b2ff67527/go.mod h1:h1NjWce9XRLGQEsW7w
|
||||||
golang.org/x/sys v0.0.0-20200323222414-85ca7c5b95cd/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
golang.org/x/sys v0.0.0-20200323222414-85ca7c5b95cd/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
||||||
golang.org/x/sys v0.0.0-20200615200032-f1bc736245b1/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
golang.org/x/sys v0.0.0-20200615200032-f1bc736245b1/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
||||||
golang.org/x/sys v0.0.0-20200622214017-ed371f2e16b4/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
golang.org/x/sys v0.0.0-20200622214017-ed371f2e16b4/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
||||||
golang.org/x/sys v0.0.0-20201119102817-f84b799fce68/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
golang.org/x/sys v0.0.0-20200930185726-fdedc70b468f h1:+Nyd8tzPX9R7BWHguqsrbFdRx3WQ/1ib8I44HXV5yTA=
|
||||||
golang.org/x/sys v0.0.0-20210615035016-665e8c7367d1/go.mod h1:oPkhp1MJrh7nUepCBck5+mAzfO9JrbApNNgaTdGDITg=
|
golang.org/x/sys v0.0.0-20200930185726-fdedc70b468f/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
|
||||||
golang.org/x/sys v0.0.0-20220520151302-bc2c85ada10a/go.mod h1:oPkhp1MJrh7nUepCBck5+mAzfO9JrbApNNgaTdGDITg=
|
|
||||||
golang.org/x/sys v0.0.0-20220722155257-8c9f86f7a55f/go.mod h1:oPkhp1MJrh7nUepCBck5+mAzfO9JrbApNNgaTdGDITg=
|
|
||||||
golang.org/x/sys v0.5.0 h1:MUK/U/4lj1t1oPg0HfuXDN/Z1wv31ZJ/YcPiGccS4DU=
|
|
||||||
golang.org/x/sys v0.5.0/go.mod h1:oPkhp1MJrh7nUepCBck5+mAzfO9JrbApNNgaTdGDITg=
|
|
||||||
golang.org/x/term v0.0.0-20201126162022-7de9c90e9dd1/go.mod h1:bj7SfCRtBDWHUb9snDiAeCFNEtKQo2Wmx5Cou7ajbmo=
|
|
||||||
golang.org/x/term v0.0.0-20210927222741-03fcf44c2211/go.mod h1:jbD1KX2456YbFQfuXm/mYQcufACuNUgVhRMnK/tPxf8=
|
|
||||||
golang.org/x/term v0.5.0/go.mod h1:jMB1sMXY+tzblOD4FWmEbocvup2/aLOaQEp7JmGp78k=
|
|
||||||
golang.org/x/text v0.3.0/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
|
golang.org/x/text v0.3.0/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
|
||||||
golang.org/x/text v0.3.1-0.20180807135948-17ff2d5776d2/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
|
golang.org/x/text v0.3.1-0.20180807135948-17ff2d5776d2/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
|
||||||
golang.org/x/text v0.3.2/go.mod h1:bEr9sfX3Q8Zfm5fL9x+3itogRgK3+ptLWKqgva+5dAk=
|
golang.org/x/text v0.3.2/go.mod h1:bEr9sfX3Q8Zfm5fL9x+3itogRgK3+ptLWKqgva+5dAk=
|
||||||
|
golang.org/x/text v0.3.3 h1:cokOdA+Jmi5PJGXLlLllQSgYigAEfHXJAERHVMaCc2k=
|
||||||
golang.org/x/text v0.3.3/go.mod h1:5Zoc/QRtKVWzQhOtBMvqHzDpF6irO9z98xDceosuGiQ=
|
golang.org/x/text v0.3.3/go.mod h1:5Zoc/QRtKVWzQhOtBMvqHzDpF6irO9z98xDceosuGiQ=
|
||||||
golang.org/x/text v0.3.7/go.mod h1:u+2+/6zg+i71rQMx5EYifcz6MCKuco9NR6JIITiCfzQ=
|
|
||||||
golang.org/x/text v0.7.0 h1:4BRB4x83lYWy72KwLD/qYDuTu7q9PjSagHvijDw7cLo=
|
|
||||||
golang.org/x/text v0.7.0/go.mod h1:mrYo+phRRbMaCq/xk9113O4dZlRixOauAjOtrjsXDZ8=
|
|
||||||
golang.org/x/time v0.0.0-20181108054448-85acf8d2951c/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
golang.org/x/time v0.0.0-20181108054448-85acf8d2951c/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
||||||
golang.org/x/time v0.0.0-20190308202827-9d24e82272b4/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
golang.org/x/time v0.0.0-20190308202827-9d24e82272b4/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
||||||
golang.org/x/time v0.0.0-20191024005414-555d28b269f0/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
golang.org/x/time v0.0.0-20191024005414-555d28b269f0/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
|
||||||
|
@ -301,10 +286,8 @@ golang.org/x/tools v0.0.0-20190628153133-6cdbf07be9d0/go.mod h1:/rFqwRUd4F7ZHNgw
|
||||||
golang.org/x/tools v0.0.0-20190816200558-6889da9d5479/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
golang.org/x/tools v0.0.0-20190816200558-6889da9d5479/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
||||||
golang.org/x/tools v0.0.0-20190911174233-4f2ddba30aff/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
golang.org/x/tools v0.0.0-20190911174233-4f2ddba30aff/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
||||||
golang.org/x/tools v0.0.0-20191012152004-8de300cfc20a/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
golang.org/x/tools v0.0.0-20191012152004-8de300cfc20a/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
||||||
golang.org/x/tools v0.0.0-20191119224855-298f0cb1881e/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
|
||||||
golang.org/x/tools v0.0.0-20191125144606-a911d9008d1f/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
golang.org/x/tools v0.0.0-20191125144606-a911d9008d1f/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
|
||||||
golang.org/x/tools v0.0.0-20191227053925-7b8e75db28f4/go.mod h1:TB2adYChydJhpapKDTa4BR/hXlZSLoq2Wpct/0txZ28=
|
golang.org/x/tools v0.0.0-20191227053925-7b8e75db28f4/go.mod h1:TB2adYChydJhpapKDTa4BR/hXlZSLoq2Wpct/0txZ28=
|
||||||
golang.org/x/tools v0.1.12/go.mod h1:hNGJHUnrk76NpqgfD5Aqm5Crs+Hm0VOH/i9J2+nxYbc=
|
|
||||||
golang.org/x/xerrors v0.0.0-20190717185122-a985d3407aa7/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
golang.org/x/xerrors v0.0.0-20190717185122-a985d3407aa7/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
||||||
golang.org/x/xerrors v0.0.0-20191011141410-1b5146add898/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
golang.org/x/xerrors v0.0.0-20191011141410-1b5146add898/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
||||||
golang.org/x/xerrors v0.0.0-20191204190536-9bdfabe68543/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
golang.org/x/xerrors v0.0.0-20191204190536-9bdfabe68543/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
|
||||||
|
|
|
@ -5,7 +5,7 @@ package vitastor
|
||||||
|
|
||||||
const (
|
const (
|
||||||
vitastorCSIDriverName = "csi.vitastor.io"
|
vitastorCSIDriverName = "csi.vitastor.io"
|
||||||
vitastorCSIDriverVersion = "1.10.0"
|
vitastorCSIDriverVersion = "1.6.1"
|
||||||
)
|
)
|
||||||
|
|
||||||
// Config struct fills the parameters of request or user input
|
// Config struct fills the parameters of request or user input
|
||||||
|
|
|
@ -8,8 +8,11 @@ import (
|
||||||
"encoding/json"
|
"encoding/json"
|
||||||
"fmt"
|
"fmt"
|
||||||
"strings"
|
"strings"
|
||||||
|
"bytes"
|
||||||
|
"strconv"
|
||||||
"time"
|
"time"
|
||||||
"os"
|
"os"
|
||||||
|
"os/exec"
|
||||||
"io/ioutil"
|
"io/ioutil"
|
||||||
|
|
||||||
"github.com/kubernetes-csi/csi-lib-utils/protosanitizer"
|
"github.com/kubernetes-csi/csi-lib-utils/protosanitizer"
|
||||||
|
@ -67,10 +70,9 @@ func GetConnectionParams(params map[string]string) (map[string]string, error)
|
||||||
{
|
{
|
||||||
configPath = "/etc/vitastor/vitastor.conf"
|
configPath = "/etc/vitastor/vitastor.conf"
|
||||||
}
|
}
|
||||||
ctxVars["configPath"] = configPath
|
else
|
||||||
if (params["vitastorfs"] != "")
|
|
||||||
{
|
{
|
||||||
ctxVars["vitastorfs"] = params["vitastorfs"]
|
ctxVars["configPath"] = configPath
|
||||||
}
|
}
|
||||||
config := make(map[string]interface{})
|
config := make(map[string]interface{})
|
||||||
configFD, err := os.Open(configPath)
|
configFD, err := os.Open(configPath)
|
||||||
|
@ -112,6 +114,22 @@ func GetConnectionParams(params map[string]string) (map[string]string, error)
|
||||||
return ctxVars, nil
|
return ctxVars, nil
|
||||||
}
|
}
|
||||||
|
|
||||||
|
func system(program string, args ...string) ([]byte, []byte, error)
|
||||||
|
{
|
||||||
|
klog.Infof("Running "+program+" "+strings.Join(args, " "))
|
||||||
|
c := exec.Command(program, args...)
|
||||||
|
var stdout, stderr bytes.Buffer
|
||||||
|
c.Stdout, c.Stderr = &stdout, &stderr
|
||||||
|
err := c.Run()
|
||||||
|
if (err != nil)
|
||||||
|
{
|
||||||
|
stdoutStr, stderrStr := string(stdout.Bytes()), string(stderr.Bytes())
|
||||||
|
klog.Errorf(program+" "+strings.Join(args, " ")+" failed: %s, status %s\n", stdoutStr+stderrStr, err)
|
||||||
|
return nil, nil, status.Error(codes.Internal, stdoutStr+stderrStr+" (status "+err.Error()+")")
|
||||||
|
}
|
||||||
|
return stdout.Bytes(), stderr.Bytes(), nil
|
||||||
|
}
|
||||||
|
|
||||||
func invokeCLI(ctxVars map[string]string, args []string) ([]byte, error)
|
func invokeCLI(ctxVars map[string]string, args []string) ([]byte, error)
|
||||||
{
|
{
|
||||||
if (ctxVars["configPath"] != "")
|
if (ctxVars["configPath"] != "")
|
||||||
|
@ -140,57 +158,27 @@ func (cs *ControllerServer) CreateVolume(ctx context.Context, req *csi.CreateVol
|
||||||
return nil, status.Error(codes.InvalidArgument, "volume capabilities is a required field")
|
return nil, status.Error(codes.InvalidArgument, "volume capabilities is a required field")
|
||||||
}
|
}
|
||||||
|
|
||||||
ctxVars, err := GetConnectionParams(req.Parameters)
|
etcdVolumePrefix := req.Parameters["etcdVolumePrefix"]
|
||||||
if (err != nil)
|
poolId, _ := strconv.ParseUint(req.Parameters["poolId"], 10, 64)
|
||||||
{
|
if (poolId == 0)
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
|
|
||||||
err = cs.checkCaps(volumeCapabilities, ctxVars["vitastorfs"] != "")
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
|
|
||||||
pool := req.Parameters["poolId"]
|
|
||||||
if (pool == "")
|
|
||||||
{
|
{
|
||||||
return nil, status.Error(codes.InvalidArgument, "poolId is missing in storage class configuration")
|
return nil, status.Error(codes.InvalidArgument, "poolId is missing in storage class configuration")
|
||||||
}
|
}
|
||||||
volumePrefix := req.Parameters["volumePrefix"]
|
|
||||||
if (volumePrefix == "")
|
volName := etcdVolumePrefix + req.GetName()
|
||||||
{
|
|
||||||
// Old name
|
|
||||||
volumePrefix = req.Parameters["etcdVolumePrefix"]
|
|
||||||
}
|
|
||||||
volName := volumePrefix + req.GetName()
|
|
||||||
volSize := 1 * GB
|
volSize := 1 * GB
|
||||||
if capRange := req.GetCapacityRange(); capRange != nil
|
if capRange := req.GetCapacityRange(); capRange != nil
|
||||||
{
|
{
|
||||||
volSize = ((capRange.GetRequiredBytes() + MB - 1) / MB) * MB
|
volSize = ((capRange.GetRequiredBytes() + MB - 1) / MB) * MB
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
ctxVars, err := GetConnectionParams(req.Parameters)
|
||||||
|
if (err != nil)
|
||||||
{
|
{
|
||||||
// Nothing to create, subdirectories are created during mounting
|
return nil, err
|
||||||
// FIXME: It would be cool to support quotas some day and set it here
|
|
||||||
if (req.VolumeContentSource.GetSnapshot() != nil)
|
|
||||||
{
|
|
||||||
return nil, status.Error(codes.InvalidArgument, "VitastorFS doesn't support snapshots")
|
|
||||||
}
|
|
||||||
ctxVars["name"] = volName
|
|
||||||
ctxVars["pool"] = pool
|
|
||||||
volumeIdJson, _ := json.Marshal(ctxVars)
|
|
||||||
return &csi.CreateVolumeResponse{
|
|
||||||
Volume: &csi.Volume{
|
|
||||||
// Ugly, but VolumeContext isn't passed to DeleteVolume :-(
|
|
||||||
VolumeId: string(volumeIdJson),
|
|
||||||
CapacityBytes: volSize,
|
|
||||||
},
|
|
||||||
}, nil
|
|
||||||
}
|
}
|
||||||
|
|
||||||
args := []string{ "create", volName, "-s", fmt.Sprintf("%v", volSize), "--pool", pool }
|
args := []string{ "create", volName, "-s", fmt.Sprintf("%v", volSize), "--pool", fmt.Sprintf("%v", poolId) }
|
||||||
|
|
||||||
// Support creation from snapshot
|
// Support creation from snapshot
|
||||||
var src *csi.VolumeContentSource
|
var src *csi.VolumeContentSource
|
||||||
|
@ -273,12 +261,6 @@ func (cs *ControllerServer) DeleteVolume(ctx context.Context, req *csi.DeleteVol
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
// FIXME: Delete FS subdirectory
|
|
||||||
return &csi.DeleteVolumeResponse{}, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
_, err = invokeCLI(ctxVars, []string{ "rm", volName })
|
_, err = invokeCLI(ctxVars, []string{ "rm", volName })
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
@ -313,72 +295,19 @@ func (cs *ControllerServer) ValidateVolumeCapabilities(ctx context.Context, req
|
||||||
{
|
{
|
||||||
return nil, status.Error(codes.InvalidArgument, "volumeId is nil")
|
return nil, status.Error(codes.InvalidArgument, "volumeId is nil")
|
||||||
}
|
}
|
||||||
volVars := make(map[string]string)
|
|
||||||
err := json.Unmarshal([]byte(volumeID), &volVars)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
|
|
||||||
}
|
|
||||||
ctxVars, err := GetConnectionParams(volVars)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
|
|
||||||
volumeCapabilities := req.GetVolumeCapabilities()
|
volumeCapabilities := req.GetVolumeCapabilities()
|
||||||
if (volumeCapabilities == nil)
|
if (volumeCapabilities == nil)
|
||||||
{
|
{
|
||||||
return nil, status.Error(codes.InvalidArgument, "volumeCapabilities is nil")
|
return nil, status.Error(codes.InvalidArgument, "volumeCapabilities is nil")
|
||||||
}
|
}
|
||||||
|
|
||||||
err = cs.checkCaps(volumeCapabilities, ctxVars["vitastorfs"] != "")
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
|
|
||||||
return &csi.ValidateVolumeCapabilitiesResponse{
|
|
||||||
Confirmed: &csi.ValidateVolumeCapabilitiesResponse_Confirmed{
|
|
||||||
VolumeCapabilities: req.VolumeCapabilities,
|
|
||||||
},
|
|
||||||
}, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
func (cs *ControllerServer) checkCaps(volumeCapabilities []*csi.VolumeCapability, fs bool) error
|
|
||||||
{
|
|
||||||
var volumeCapabilityAccessModes []*csi.VolumeCapability_AccessMode
|
var volumeCapabilityAccessModes []*csi.VolumeCapability_AccessMode
|
||||||
for _, mode := range []csi.VolumeCapability_AccessMode_Mode{
|
for _, mode := range []csi.VolumeCapability_AccessMode_Mode{
|
||||||
csi.VolumeCapability_AccessMode_SINGLE_NODE_WRITER,
|
csi.VolumeCapability_AccessMode_SINGLE_NODE_WRITER,
|
||||||
csi.VolumeCapability_AccessMode_SINGLE_NODE_READER_ONLY,
|
|
||||||
csi.VolumeCapability_AccessMode_MULTI_NODE_READER_ONLY,
|
|
||||||
csi.VolumeCapability_AccessMode_SINGLE_NODE_SINGLE_WRITER,
|
|
||||||
csi.VolumeCapability_AccessMode_SINGLE_NODE_MULTI_WRITER,
|
|
||||||
} {
|
|
||||||
volumeCapabilityAccessModes = append(volumeCapabilityAccessModes, &csi.VolumeCapability_AccessMode{Mode: mode})
|
|
||||||
}
|
|
||||||
for _, capability := range volumeCapabilities
|
|
||||||
{
|
|
||||||
if (capability.GetBlock() != nil)
|
|
||||||
{
|
|
||||||
if (fs)
|
|
||||||
{
|
|
||||||
return status.Errorf(codes.InvalidArgument, "%v not supported with FS-based volumes", capability)
|
|
||||||
}
|
|
||||||
for _, mode := range []csi.VolumeCapability_AccessMode_Mode{
|
|
||||||
csi.VolumeCapability_AccessMode_MULTI_NODE_SINGLE_WRITER,
|
|
||||||
csi.VolumeCapability_AccessMode_MULTI_NODE_MULTI_WRITER,
|
csi.VolumeCapability_AccessMode_MULTI_NODE_MULTI_WRITER,
|
||||||
} {
|
} {
|
||||||
volumeCapabilityAccessModes = append(volumeCapabilityAccessModes, &csi.VolumeCapability_AccessMode{Mode: mode})
|
volumeCapabilityAccessModes = append(volumeCapabilityAccessModes, &csi.VolumeCapability_AccessMode{Mode: mode})
|
||||||
}
|
}
|
||||||
break
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
if (fs)
|
|
||||||
{
|
|
||||||
// All access modes including RWX are supported with FS-based volumes
|
|
||||||
return nil
|
|
||||||
}
|
|
||||||
|
|
||||||
capabilitySupport := false
|
capabilitySupport := false
|
||||||
for _, capability := range volumeCapabilities
|
for _, capability := range volumeCapabilities
|
||||||
|
@ -394,10 +323,14 @@ func (cs *ControllerServer) checkCaps(volumeCapabilities []*csi.VolumeCapability
|
||||||
|
|
||||||
if (!capabilitySupport)
|
if (!capabilitySupport)
|
||||||
{
|
{
|
||||||
return status.Errorf(codes.InvalidArgument, "%v not supported", volumeCapabilities)
|
return nil, status.Errorf(codes.NotFound, "%v not supported", req.GetVolumeCapabilities())
|
||||||
}
|
}
|
||||||
|
|
||||||
return nil
|
return &csi.ValidateVolumeCapabilitiesResponse{
|
||||||
|
Confirmed: &csi.ValidateVolumeCapabilitiesResponse_Confirmed{
|
||||||
|
VolumeCapabilities: req.VolumeCapabilities,
|
||||||
|
},
|
||||||
|
}, nil
|
||||||
}
|
}
|
||||||
|
|
||||||
// ListVolumes returns a list of volumes
|
// ListVolumes returns a list of volumes
|
||||||
|
@ -486,12 +419,6 @@ func (cs *ControllerServer) CreateSnapshot(ctx context.Context, req *csi.CreateS
|
||||||
{
|
{
|
||||||
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
|
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
return nil, status.Error(codes.InvalidArgument, "VitastorFS doesn't support snapshots")
|
|
||||||
}
|
|
||||||
|
|
||||||
volName := ctxVars["name"]
|
volName := ctxVars["name"]
|
||||||
|
|
||||||
// Create image using vitastor-cli
|
// Create image using vitastor-cli
|
||||||
|
@ -550,11 +477,6 @@ func (cs *ControllerServer) DeleteSnapshot(ctx context.Context, req *csi.DeleteS
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
return nil, status.Error(codes.InvalidArgument, "VitastorFS doesn't support snapshots")
|
|
||||||
}
|
|
||||||
|
|
||||||
_, err = invokeCLI(ctxVars, []string{ "rm", volName+"@"+snapName })
|
_, err = invokeCLI(ctxVars, []string{ "rm", volName+"@"+snapName })
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
@ -586,11 +508,6 @@ func (cs *ControllerServer) ListSnapshots(ctx context.Context, req *csi.ListSnap
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
return nil, status.Error(codes.InvalidArgument, "VitastorFS doesn't support snapshots")
|
|
||||||
}
|
|
||||||
|
|
||||||
inodeCfg, err := invokeList(ctxVars, volName+"@*", false)
|
inodeCfg, err := invokeList(ctxVars, volName+"@*", false)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
@ -654,16 +571,6 @@ func (cs *ControllerServer) ControllerExpandVolume(ctx context.Context, req *csi
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
// Nothing to change
|
|
||||||
// FIXME: Support quotas and change quota here
|
|
||||||
return &csi.ControllerExpandVolumeResponse{
|
|
||||||
CapacityBytes: req.CapacityRange.RequiredBytes,
|
|
||||||
NodeExpansionRequired: false,
|
|
||||||
}, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
inodeCfg, err := invokeList(ctxVars, volName, true)
|
inodeCfg, err := invokeList(ctxVars, volName, true)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
|
|
@ -5,15 +5,11 @@ package vitastor
|
||||||
|
|
||||||
import (
|
import (
|
||||||
"context"
|
"context"
|
||||||
"crypto/sha1"
|
|
||||||
"encoding/hex"
|
|
||||||
"encoding/json"
|
"encoding/json"
|
||||||
"fmt"
|
"fmt"
|
||||||
"os"
|
"os"
|
||||||
"os/exec"
|
"os/exec"
|
||||||
"path/filepath"
|
"path/filepath"
|
||||||
"regexp"
|
|
||||||
"strconv"
|
|
||||||
"strings"
|
"strings"
|
||||||
"sync"
|
"sync"
|
||||||
"syscall"
|
"syscall"
|
||||||
|
@ -35,7 +31,6 @@ type NodeServer struct
|
||||||
*Driver
|
*Driver
|
||||||
useVduse bool
|
useVduse bool
|
||||||
stateDir string
|
stateDir string
|
||||||
nfsStageDir string
|
|
||||||
mounter mount.Interface
|
mounter mount.Interface
|
||||||
restartInterval time.Duration
|
restartInterval time.Duration
|
||||||
mu sync.Mutex
|
mu sync.Mutex
|
||||||
|
@ -53,15 +48,6 @@ type DeviceState struct
|
||||||
PidFile string `json:"pidFile"`
|
PidFile string `json:"pidFile"`
|
||||||
}
|
}
|
||||||
|
|
||||||
type NfsState struct
|
|
||||||
{
|
|
||||||
ConfigPath string `json:"configPath"`
|
|
||||||
FsName string `json:"fsName"`
|
|
||||||
Pool string `json:"pool"`
|
|
||||||
Path string `json:"path"`
|
|
||||||
Port int `json:"port"`
|
|
||||||
}
|
|
||||||
|
|
||||||
// NewNodeServer create new instance node
|
// NewNodeServer create new instance node
|
||||||
func NewNodeServer(driver *Driver) *NodeServer
|
func NewNodeServer(driver *Driver) *NodeServer
|
||||||
{
|
{
|
||||||
|
@ -74,16 +60,10 @@ func NewNodeServer(driver *Driver) *NodeServer
|
||||||
{
|
{
|
||||||
stateDir += "/"
|
stateDir += "/"
|
||||||
}
|
}
|
||||||
nfsStageDir := os.Getenv("NFS_STAGE_DIR")
|
|
||||||
if (nfsStageDir == "")
|
|
||||||
{
|
|
||||||
nfsStageDir = "/var/lib/kubelet/plugins/csi.vitastor.io/nfs"
|
|
||||||
}
|
|
||||||
ns := &NodeServer{
|
ns := &NodeServer{
|
||||||
Driver: driver,
|
Driver: driver,
|
||||||
useVduse: checkVduseSupport(),
|
useVduse: checkVduseSupport(),
|
||||||
stateDir: stateDir,
|
stateDir: stateDir,
|
||||||
nfsStageDir: nfsStageDir,
|
|
||||||
mounter: mount.New(""),
|
mounter: mount.New(""),
|
||||||
volumeLocks: make(map[string]bool),
|
volumeLocks: make(map[string]bool),
|
||||||
}
|
}
|
||||||
|
@ -143,12 +123,12 @@ func (ns *NodeServer) restarter()
|
||||||
func (ns *NodeServer) restoreVduseDaemons()
|
func (ns *NodeServer) restoreVduseDaemons()
|
||||||
{
|
{
|
||||||
pattern := ns.stateDir+"vitastor-vduse-*.json"
|
pattern := ns.stateDir+"vitastor-vduse-*.json"
|
||||||
stateFiles, err := filepath.Glob(pattern)
|
matches, err := filepath.Glob(pattern)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
klog.Errorf("failed to list %s: %v", pattern, err)
|
klog.Errorf("failed to list %s: %v", pattern, err)
|
||||||
}
|
}
|
||||||
if (len(stateFiles) == 0)
|
if (len(matches) == 0)
|
||||||
{
|
{
|
||||||
return
|
return
|
||||||
}
|
}
|
||||||
|
@ -166,49 +146,41 @@ func (ns *NodeServer) restoreVduseDaemons()
|
||||||
klog.Errorf("/sbin/vdpa -j dev list returned bad JSON (error %v): %v", err, string(devListJSON))
|
klog.Errorf("/sbin/vdpa -j dev list returned bad JSON (error %v): %v", err, string(devListJSON))
|
||||||
return
|
return
|
||||||
}
|
}
|
||||||
for _, stateFile := range stateFiles
|
for _, stateFile := range matches
|
||||||
{
|
{
|
||||||
ns.checkVduseState(stateFile, devs)
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) checkVduseState(stateFile string, devs map[string]interface{})
|
|
||||||
{
|
|
||||||
// Check if VDPA device is still added to the bus
|
|
||||||
vdpaId := filepath.Base(stateFile)
|
vdpaId := filepath.Base(stateFile)
|
||||||
vdpaId = vdpaId[0:len(vdpaId)-5]
|
vdpaId = vdpaId[0:len(vdpaId)-5]
|
||||||
|
// Check if VDPA device is still added to the bus
|
||||||
if (devs[vdpaId] == nil)
|
if (devs[vdpaId] == nil)
|
||||||
{
|
{
|
||||||
// Unused, clean it up
|
// Unused, clean it up
|
||||||
unmapVduseById(ns.stateDir, vdpaId)
|
unmapVduseById(ns.stateDir, vdpaId)
|
||||||
return
|
continue
|
||||||
}
|
}
|
||||||
|
|
||||||
// Read state file
|
|
||||||
stateJSON, err := os.ReadFile(stateFile)
|
stateJSON, err := os.ReadFile(stateFile)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
klog.Warningf("error reading state file %v: %v", stateFile, err)
|
klog.Warningf("error reading state file %v: %v", stateFile, err)
|
||||||
return
|
continue
|
||||||
}
|
}
|
||||||
var state DeviceState
|
var state DeviceState
|
||||||
err = json.Unmarshal(stateJSON, &state)
|
err = json.Unmarshal(stateJSON, &state)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
klog.Warningf("state file %v contains invalid JSON (error %v): %v", stateFile, err, string(stateJSON))
|
klog.Warningf("state file %v contains invalid JSON (error %v): %v", stateFile, err, string(stateJSON))
|
||||||
return
|
continue
|
||||||
}
|
}
|
||||||
|
|
||||||
// Lock volume
|
ns.lockVolume(state.ConfigPath+":"+state.Image)
|
||||||
ns.lockVolume(state.ConfigPath+":block:"+state.Image)
|
|
||||||
defer ns.unlockVolume(state.ConfigPath+":block:"+state.Image)
|
|
||||||
|
|
||||||
// Recheck state file after locking
|
// Recheck state file after locking
|
||||||
_, err = os.ReadFile(stateFile)
|
_, err = os.ReadFile(stateFile)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
klog.Warningf("state file %v disappeared, skipping volume", stateFile)
|
klog.Warningf("state file %v disappeared, skipping volume", stateFile)
|
||||||
return
|
ns.unlockVolume(state.ConfigPath+":"+state.Image)
|
||||||
|
continue
|
||||||
}
|
}
|
||||||
|
|
||||||
// Check if the storage daemon is still active
|
// Check if the storage daemon is still active
|
||||||
|
@ -223,105 +195,10 @@ func (ns *NodeServer) checkVduseState(stateFile string, devs map[string]interfac
|
||||||
{
|
{
|
||||||
// Restart daemon
|
// Restart daemon
|
||||||
klog.Warningf("restarting storage daemon for volume %v (VDPA ID %v)", state.Image, vdpaId)
|
klog.Warningf("restarting storage daemon for volume %v (VDPA ID %v)", state.Image, vdpaId)
|
||||||
err = startStorageDaemon(vdpaId, state.Image, pidFile, state.ConfigPath, state.Readonly)
|
_ = startStorageDaemon(vdpaId, state.Image, pidFile, state.ConfigPath, state.Readonly)
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Warningf("failed to restart storage daemon for volume %v: %v", state.Image, err)
|
|
||||||
}
|
}
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) restoreNfsDaemons()
|
ns.unlockVolume(state.ConfigPath+":"+state.Image)
|
||||||
{
|
|
||||||
pattern := ns.stateDir+"vitastor-nfs-*.json"
|
|
||||||
stateFiles, err := filepath.Glob(pattern)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to list %s: %v", pattern, err)
|
|
||||||
}
|
|
||||||
if (len(stateFiles) == 0)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
activeNFS, err := ns.listActiveNFS()
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
// Check all state files and try to restore active mounts
|
|
||||||
for _, stateFile := range stateFiles
|
|
||||||
{
|
|
||||||
ns.checkNfsState(stateFile, activeNFS)
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) readNfsState(stateFile string, allowNotExists bool) (*NfsState, error)
|
|
||||||
{
|
|
||||||
stateJSON, err := os.ReadFile(stateFile)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
if (allowNotExists && os.IsNotExist(err))
|
|
||||||
{
|
|
||||||
return nil, nil
|
|
||||||
}
|
|
||||||
klog.Warningf("error reading state file %v: %v", stateFile, err)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
var state NfsState
|
|
||||||
err = json.Unmarshal(stateJSON, &state)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Warningf("state file %v contains invalid JSON (error %v): %v", stateFile, err, string(stateJSON))
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
return &state, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) checkNfsState(stateFile string, activeNfs map[int][]string)
|
|
||||||
{
|
|
||||||
// Read state file
|
|
||||||
state, err := ns.readNfsState(stateFile, false)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
// Lock FS
|
|
||||||
ns.lockVolume(state.ConfigPath+":fs:"+state.FsName)
|
|
||||||
defer ns.unlockVolume(state.ConfigPath+":fs:"+state.FsName)
|
|
||||||
// Check if NFS at this port is still mounted
|
|
||||||
pidFile := ns.stateDir + filepath.Base(stateFile)
|
|
||||||
pidFile = pidFile[0:len(pidFile)-5] + ".pid"
|
|
||||||
if (len(activeNfs[state.Port]) == 0)
|
|
||||||
{
|
|
||||||
// this is a stale state file, remove it
|
|
||||||
klog.Warningf("state file %v contains stale mount at port %d, removing it", stateFile, state.Port)
|
|
||||||
ns.stopNFS(stateFile, pidFile)
|
|
||||||
return
|
|
||||||
}
|
|
||||||
// Check PID file
|
|
||||||
exists := false
|
|
||||||
proc, err := findByPidFile(pidFile)
|
|
||||||
if (err == nil)
|
|
||||||
{
|
|
||||||
exists = proc.Signal(syscall.Signal(0)) == nil
|
|
||||||
}
|
|
||||||
if (!exists)
|
|
||||||
{
|
|
||||||
// Restart vitastor-nfs server
|
|
||||||
klog.Warningf("restarting NFS server for FS %v at port %v", state.FsName, state.Port)
|
|
||||||
_, _, err := system(
|
|
||||||
"/usr/bin/vitastor-nfs", "start",
|
|
||||||
"--pidfile", pidFile,
|
|
||||||
"--bind", "127.0.0.1",
|
|
||||||
"--port", fmt.Sprintf("%d", state.Port),
|
|
||||||
"--fs", state.FsName,
|
|
||||||
"--pool", state.Pool,
|
|
||||||
"--portmap", "0",
|
|
||||||
)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Warningf("failed to restart NFS server for FS %v: %v", state.FsName, err)
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -343,44 +220,14 @@ func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVol
|
||||||
}
|
}
|
||||||
volName := ctxVars["name"]
|
volName := ctxVars["name"]
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
ns.lockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
{
|
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
return &csi.NodeStageVolumeResponse{}, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
ns.lockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
|
|
||||||
targetPath := req.GetStagingTargetPath()
|
targetPath := req.GetStagingTargetPath()
|
||||||
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
||||||
|
|
||||||
// Check that it's not already mounted
|
// Check that it's not already mounted
|
||||||
notmnt, err := mount.IsNotMountPoint(ns.mounter, targetPath)
|
_, err = mount.IsNotMountPoint(ns.mounter, targetPath)
|
||||||
if (err == nil)
|
|
||||||
{
|
|
||||||
if (!notmnt)
|
|
||||||
{
|
|
||||||
klog.Errorf("target path %s is already mounted", targetPath)
|
|
||||||
return nil, fmt.Errorf("target path %s is already mounted", targetPath)
|
|
||||||
}
|
|
||||||
var finfo os.FileInfo
|
|
||||||
finfo, err = os.Stat(targetPath)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to stat %s: %v", targetPath, err)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
if (finfo.IsDir() != (!isBlock))
|
|
||||||
{
|
|
||||||
err = os.Remove(targetPath)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to remove %s (to recreate it with correct type): %v", targetPath, err)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
err = os.ErrNotExist
|
|
||||||
}
|
|
||||||
}
|
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
if (os.IsNotExist(err))
|
if (os.IsNotExist(err))
|
||||||
|
@ -433,7 +280,6 @@ func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVol
|
||||||
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
|
||||||
if (isBlock)
|
if (isBlock)
|
||||||
{
|
{
|
||||||
klog.Infof("bind-mounting %s to %s", devicePath, targetPath)
|
|
||||||
err = diskMounter.Mount(devicePath, targetPath, "", []string{"bind"})
|
err = diskMounter.Mount(devicePath, targetPath, "", []string{"bind"})
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
|
@ -463,40 +309,39 @@ func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVol
|
||||||
readOnly := Contains(opt, "ro")
|
readOnly := Contains(opt, "ro")
|
||||||
if (existingFormat == "" && !readOnly)
|
if (existingFormat == "" && !readOnly)
|
||||||
{
|
{
|
||||||
|
var cmdOut []byte
|
||||||
switch fsType
|
switch fsType
|
||||||
{
|
{
|
||||||
case "ext4":
|
case "ext4":
|
||||||
args := []string{"-m0", "-Enodiscard,lazy_itable_init=1,lazy_journal_init=1", devicePath}
|
args := []string{"-m0", "-Enodiscard,lazy_itable_init=1,lazy_journal_init=1", devicePath}
|
||||||
_, err = systemCombined("mkfs.ext4", args...)
|
cmdOut, err = diskMounter.Exec.Command("mkfs.ext4", args...).CombinedOutput()
|
||||||
case "xfs":
|
case "xfs":
|
||||||
_, err = systemCombined("mkfs.xfs", "-K", devicePath)
|
cmdOut, err = diskMounter.Exec.Command("mkfs.xfs", "-K", devicePath).CombinedOutput()
|
||||||
}
|
}
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
klog.Errorf("failed to run mkfs error: %v, output: %v", err, string(cmdOut))
|
||||||
goto unmap
|
goto unmap
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
klog.Infof("formatting and mounting %s to %s with FS %s, options: %v", devicePath, targetPath, fsType, opt)
|
|
||||||
err = diskMounter.FormatAndMount(devicePath, targetPath, fsType, opt)
|
err = diskMounter.FormatAndMount(devicePath, targetPath, fsType, opt)
|
||||||
if (err == nil)
|
|
||||||
{
|
|
||||||
klog.Infof("successfully mounted %s to %s", devicePath, targetPath)
|
|
||||||
}
|
|
||||||
|
|
||||||
// Try to run online resize on mount.
|
// Try to run online resize on mount.
|
||||||
// FIXME: Implement online resize. It requires online resize support in vitastor-nbd.
|
// FIXME: Implement online resize. It requires online resize support in vitastor-nbd.
|
||||||
if (err == nil && existingFormat != "" && !readOnly)
|
if (err == nil && existingFormat != "" && !readOnly)
|
||||||
{
|
{
|
||||||
|
var cmdOut []byte
|
||||||
switch (fsType)
|
switch (fsType)
|
||||||
{
|
{
|
||||||
case "ext4":
|
case "ext4":
|
||||||
_, err = systemCombined("resize2fs", devicePath)
|
cmdOut, err = diskMounter.Exec.Command("resize2fs", devicePath).CombinedOutput()
|
||||||
case "xfs":
|
case "xfs":
|
||||||
_, err = systemCombined("xfs_growfs", devicePath)
|
cmdOut, err = diskMounter.Exec.Command("xfs_growfs", devicePath).CombinedOutput()
|
||||||
}
|
}
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
|
klog.Errorf("failed to run resizefs error: %v, output: %v", err, string(cmdOut))
|
||||||
goto unmap
|
goto unmap
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
@ -536,16 +381,11 @@ func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstag
|
||||||
}
|
}
|
||||||
volName := ctxVars["name"]
|
volName := ctxVars["name"]
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
ns.lockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
{
|
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
return &csi.NodeUnstageVolumeResponse{}, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
ns.lockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
|
|
||||||
targetPath := req.GetStagingTargetPath()
|
targetPath := req.GetStagingTargetPath()
|
||||||
devicePath, _, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
|
devicePath, refCount, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
if (os.IsNotExist(err))
|
if (os.IsNotExist(err))
|
||||||
|
@ -562,16 +402,6 @@ func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstag
|
||||||
return &csi.NodeUnstageVolumeResponse{}, nil
|
return &csi.NodeUnstageVolumeResponse{}, nil
|
||||||
}
|
}
|
||||||
|
|
||||||
refList, err := ns.mounter.GetMountRefs(targetPath)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
if (len(refList) > 0)
|
|
||||||
{
|
|
||||||
klog.Warningf("%s is still referenced: %v", targetPath, refList)
|
|
||||||
}
|
|
||||||
|
|
||||||
// unmount
|
// unmount
|
||||||
err = mount.CleanupMountPoint(targetPath, ns.mounter, false)
|
err = mount.CleanupMountPoint(targetPath, ns.mounter, false)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
|
@ -580,7 +410,7 @@ func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstag
|
||||||
}
|
}
|
||||||
|
|
||||||
// unmap device
|
// unmap device
|
||||||
if (len(refList) == 0)
|
if (refCount == 1)
|
||||||
{
|
{
|
||||||
if (!ns.useVduse)
|
if (!ns.useVduse)
|
||||||
{
|
{
|
||||||
|
@ -595,153 +425,6 @@ func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstag
|
||||||
return &csi.NodeUnstageVolumeResponse{}, nil
|
return &csi.NodeUnstageVolumeResponse{}, nil
|
||||||
}
|
}
|
||||||
|
|
||||||
// Mount or check if NFS is already mounted
|
|
||||||
func (ns *NodeServer) mountNFS(ctxVars map[string]string) (string, error)
|
|
||||||
{
|
|
||||||
sum := sha1.Sum([]byte(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"]))
|
|
||||||
nfsHash := hex.EncodeToString(sum[:])
|
|
||||||
stateFile := ns.stateDir+"vitastor-nfs-"+nfsHash+".json"
|
|
||||||
pidFile := ns.stateDir+"vitastor-nfs-"+nfsHash+".pid"
|
|
||||||
mountPath := ns.nfsStageDir+"/"+nfsHash
|
|
||||||
state, err := ns.readNfsState(stateFile, true)
|
|
||||||
if (state != nil)
|
|
||||||
{
|
|
||||||
return state.Path, nil
|
|
||||||
}
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return "", err
|
|
||||||
}
|
|
||||||
err = os.MkdirAll(mountPath, 0777)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return "", err
|
|
||||||
}
|
|
||||||
// Create a new mount
|
|
||||||
state = &NfsState{
|
|
||||||
ConfigPath: ctxVars["configPath"],
|
|
||||||
FsName: ctxVars["vitastorfs"],
|
|
||||||
Pool: ctxVars["pool"],
|
|
||||||
Path: mountPath,
|
|
||||||
}
|
|
||||||
klog.Infof("starting new NFS server for FS %v", state.FsName)
|
|
||||||
stdout, _, err := system(
|
|
||||||
"/usr/bin/vitastor-nfs", "start",
|
|
||||||
"--pidfile", pidFile,
|
|
||||||
"--bind", "127.0.0.1",
|
|
||||||
"--port", "auto",
|
|
||||||
"--fs", state.FsName,
|
|
||||||
"--pool", state.Pool,
|
|
||||||
"--portmap", "0",
|
|
||||||
)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return "", err
|
|
||||||
}
|
|
||||||
match := regexp.MustCompile("Port: (\\d+)").FindStringSubmatch(string(stdout))
|
|
||||||
if (match == nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to find port in vitastor-nfs output: %v", string(stdout))
|
|
||||||
ns.stopNFS(stateFile, pidFile)
|
|
||||||
return "", fmt.Errorf("failed to find port in vitastor-nfs output (bad vitastor-nfs version?)")
|
|
||||||
}
|
|
||||||
port, _ := strconv.ParseUint(match[1], 0, 16)
|
|
||||||
state.Port = int(port)
|
|
||||||
// Write state file
|
|
||||||
stateJSON, _ := json.Marshal(state)
|
|
||||||
err = os.WriteFile(stateFile, stateJSON, 0600)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to write state file %v", stateFile)
|
|
||||||
ns.stopNFS(stateFile, pidFile)
|
|
||||||
return "", err
|
|
||||||
}
|
|
||||||
// Mount NFS
|
|
||||||
_, _, err = system(
|
|
||||||
"mount", "-t", "nfs", "127.0.0.1:/", state.Path,
|
|
||||||
"-o", fmt.Sprintf("port=%d,mountport=%d,nfsvers=3,soft,nolock,tcp", port, port),
|
|
||||||
)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
ns.stopNFS(stateFile, pidFile)
|
|
||||||
return "", err
|
|
||||||
}
|
|
||||||
return state.Path, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
// Mount or check if NFS is already mounted
|
|
||||||
func (ns *NodeServer) checkStopNFS(ctxVars map[string]string)
|
|
||||||
{
|
|
||||||
sum := sha1.Sum([]byte(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"]))
|
|
||||||
nfsHash := hex.EncodeToString(sum[:])
|
|
||||||
stateFile := ns.stateDir+"vitastor-nfs-"+nfsHash+".json"
|
|
||||||
pidFile := ns.stateDir+"vitastor-nfs-"+nfsHash+".pid"
|
|
||||||
mountPath := ns.nfsStageDir+"/"+nfsHash
|
|
||||||
state, err := ns.readNfsState(stateFile, true)
|
|
||||||
if (state == nil)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
activeNFS, err := ns.listActiveNFS()
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
if (len(activeNFS[state.Port]) > 0)
|
|
||||||
{
|
|
||||||
return
|
|
||||||
}
|
|
||||||
// All volume mounts are detached, unmount the root mount and kill the server
|
|
||||||
err = mount.CleanupMountPoint(mountPath, ns.mounter, false)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to unmount %v: %v", mountPath, err)
|
|
||||||
return
|
|
||||||
}
|
|
||||||
ns.stopNFS(stateFile, pidFile)
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) stopNFS(stateFile, pidFile string)
|
|
||||||
{
|
|
||||||
err := killByPidFile(pidFile)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to kill process with pid from %v: %v", pidFile, err)
|
|
||||||
}
|
|
||||||
os.Remove(pidFile)
|
|
||||||
os.Remove(stateFile)
|
|
||||||
}
|
|
||||||
|
|
||||||
func (ns *NodeServer) listActiveNFS() (map[int][]string, error)
|
|
||||||
{
|
|
||||||
mounts, err := mount.ParseMountInfo("/proc/self/mountinfo")
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
klog.Errorf("failed to list mounts: %v", err)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
activeNFS := make(map[int][]string)
|
|
||||||
for _, mount := range mounts
|
|
||||||
{
|
|
||||||
// Volume mounts always refer to subpaths
|
|
||||||
if (mount.FsType == "nfs" && mount.Root != "/")
|
|
||||||
{
|
|
||||||
for _, opt := range mount.MountOptions
|
|
||||||
{
|
|
||||||
if (strings.HasPrefix(opt, "port="))
|
|
||||||
{
|
|
||||||
port64, err := strconv.ParseUint(opt[5:], 10, 16)
|
|
||||||
if (err == nil)
|
|
||||||
{
|
|
||||||
activeNFS[int(port64)] = append(activeNFS[int(port64)], mount.MountPoint)
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return activeNFS, nil
|
|
||||||
}
|
|
||||||
|
|
||||||
// NodePublishVolume mounts the volume mounted to the staging path to the target path
|
// NodePublishVolume mounts the volume mounted to the staging path to the target path
|
||||||
func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublishVolumeRequest) (*csi.NodePublishVolumeResponse, error)
|
func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublishVolumeRequest) (*csi.NodePublishVolumeResponse, error)
|
||||||
{
|
{
|
||||||
|
@ -760,39 +443,23 @@ func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublis
|
||||||
}
|
}
|
||||||
volName := ctxVars["name"]
|
volName := ctxVars["name"]
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
ns.lockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
{
|
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
ns.lockVolume(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"])
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"])
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
ns.lockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
}
|
|
||||||
|
|
||||||
stagingTargetPath := req.GetStagingTargetPath()
|
stagingTargetPath := req.GetStagingTargetPath()
|
||||||
targetPath := req.GetTargetPath()
|
targetPath := req.GetTargetPath()
|
||||||
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
isBlock := req.GetVolumeCapability().GetBlock() != nil
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] == "")
|
|
||||||
{
|
|
||||||
// Check that stagingTargetPath is mounted
|
// Check that stagingTargetPath is mounted
|
||||||
notmnt, err := mount.IsNotMountPoint(ns.mounter, stagingTargetPath)
|
_, err = mount.IsNotMountPoint(ns.mounter, stagingTargetPath)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
klog.Errorf("staging path %v is not mounted: %w", stagingTargetPath, err)
|
klog.Errorf("staging path %v is not mounted: %v", stagingTargetPath, err)
|
||||||
return nil, fmt.Errorf("staging path %v is not mounted: %w", stagingTargetPath, err)
|
return nil, fmt.Errorf("staging path %v is not mounted: %v", stagingTargetPath, err)
|
||||||
}
|
|
||||||
else if (notmnt)
|
|
||||||
{
|
|
||||||
klog.Errorf("staging path %v is not mounted", stagingTargetPath)
|
|
||||||
return nil, fmt.Errorf("staging path %v is not mounted", stagingTargetPath)
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
|
|
||||||
// Check that targetPath is not already mounted
|
// Check that targetPath is not already mounted
|
||||||
notmnt, err := mount.IsNotMountPoint(ns.mounter, targetPath)
|
_, err = mount.IsNotMountPoint(ns.mounter, targetPath)
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
if (os.IsNotExist(err))
|
if (os.IsNotExist(err))
|
||||||
|
@ -827,29 +494,6 @@ func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublis
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
else if (!notmnt)
|
|
||||||
{
|
|
||||||
klog.Errorf("target path %s is already mounted", targetPath)
|
|
||||||
return nil, fmt.Errorf("target path %s is already mounted", targetPath)
|
|
||||||
}
|
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
nfspath, err := ns.mountNFS(ctxVars)
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
ns.checkStopNFS(ctxVars)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
// volName should include prefix
|
|
||||||
stagingTargetPath = nfspath+"/"+volName
|
|
||||||
err = os.MkdirAll(stagingTargetPath, 0777)
|
|
||||||
if (err != nil && !os.IsExist(err))
|
|
||||||
{
|
|
||||||
ns.checkStopNFS(ctxVars)
|
|
||||||
return nil, err
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
execArgs := []string{"--bind", stagingTargetPath, targetPath}
|
execArgs := []string{"--bind", stagingTargetPath, targetPath}
|
||||||
if (req.GetReadonly())
|
if (req.GetReadonly())
|
||||||
|
@ -862,10 +506,6 @@ func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublis
|
||||||
out, err := cmd.Output()
|
out, err := cmd.Output()
|
||||||
if (err != nil)
|
if (err != nil)
|
||||||
{
|
{
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
ns.checkStopNFS(ctxVars)
|
|
||||||
}
|
|
||||||
return nil, fmt.Errorf("Error running mount %v: %s", strings.Join(execArgs, " "), out)
|
return nil, fmt.Errorf("Error running mount %v: %s", strings.Join(execArgs, " "), out)
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -885,16 +525,8 @@ func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpu
|
||||||
}
|
}
|
||||||
volName := ctxVars["name"]
|
volName := ctxVars["name"]
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
ns.lockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
{
|
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
|
||||||
ns.lockVolume(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"])
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":fs:"+ctxVars["vitastorfs"])
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
ns.lockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
defer ns.unlockVolume(ctxVars["configPath"]+":block:"+volName)
|
|
||||||
}
|
|
||||||
|
|
||||||
targetPath := req.GetTargetPath()
|
targetPath := req.GetTargetPath()
|
||||||
devicePath, _, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
|
devicePath, _, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
|
||||||
|
@ -921,11 +553,6 @@ func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpu
|
||||||
return nil, err
|
return nil, err
|
||||||
}
|
}
|
||||||
|
|
||||||
if (ctxVars["vitastorfs"] != "")
|
|
||||||
{
|
|
||||||
ns.checkStopNFS(ctxVars)
|
|
||||||
}
|
|
||||||
|
|
||||||
return &csi.NodeUnpublishVolumeResponse{}, nil
|
return &csi.NodeUnpublishVolumeResponse{}, nil
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
|
@ -4,7 +4,6 @@
|
||||||
package vitastor
|
package vitastor
|
||||||
|
|
||||||
import (
|
import (
|
||||||
"bytes"
|
|
||||||
"errors"
|
"errors"
|
||||||
"encoding/json"
|
"encoding/json"
|
||||||
"fmt"
|
"fmt"
|
||||||
|
@ -16,8 +15,6 @@ import (
|
||||||
"syscall"
|
"syscall"
|
||||||
|
|
||||||
"k8s.io/klog"
|
"k8s.io/klog"
|
||||||
"google.golang.org/grpc/codes"
|
|
||||||
"google.golang.org/grpc/status"
|
|
||||||
)
|
)
|
||||||
|
|
||||||
func Contains(list []string, s string) bool
|
func Contains(list []string, s string) bool
|
||||||
|
@ -76,10 +73,6 @@ func checkVduseSupport() bool
|
||||||
" For VDUSE you need at least Linux 5.15 and the following kernel modules: vdpa, virtio-vdpa, vduse.",
|
" For VDUSE you need at least Linux 5.15 and the following kernel modules: vdpa, virtio-vdpa, vduse.",
|
||||||
)
|
)
|
||||||
}
|
}
|
||||||
else
|
|
||||||
{
|
|
||||||
klog.Infof("VDUSE support enabled successfully")
|
|
||||||
}
|
|
||||||
return vduse
|
return vduse
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -104,7 +97,6 @@ func mapNbd(volName string, ctxVars map[string]string, readonly bool) (string, e
|
||||||
{
|
{
|
||||||
return "", fmt.Errorf("vitastor-nbd did not return the name of NBD device. output: %s", stderr)
|
return "", fmt.Errorf("vitastor-nbd did not return the name of NBD device. output: %s", stderr)
|
||||||
}
|
}
|
||||||
klog.Infof("Attached volume %s via NBD as %s", volName, dev)
|
|
||||||
return dev, err
|
return dev, err
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -225,7 +217,6 @@ func mapVduse(stateDir string, volName string, ctxVars map[string]string, readon
|
||||||
err = os.WriteFile(stateFile, stateJSON, 0600)
|
err = os.WriteFile(stateFile, stateJSON, 0600)
|
||||||
if (err == nil)
|
if (err == nil)
|
||||||
{
|
{
|
||||||
klog.Infof("Attached volume %s via VDUSE as %s (VDPA ID %s)", volName, blockdev, vdpaId)
|
|
||||||
return blockdev, vdpaId, nil
|
return blockdev, vdpaId, nil
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
@ -308,35 +299,3 @@ func unmapVduseById(stateDir, vdpaId string)
|
||||||
os.Remove(pidFile)
|
os.Remove(pidFile)
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
func system(program string, args ...string) ([]byte, []byte, error)
|
|
||||||
{
|
|
||||||
klog.Infof("Running "+program+" "+strings.Join(args, " "))
|
|
||||||
c := exec.Command(program, args...)
|
|
||||||
var stdout, stderr bytes.Buffer
|
|
||||||
c.Stdout, c.Stderr = &stdout, &stderr
|
|
||||||
err := c.Run()
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
stdoutStr, stderrStr := string(stdout.Bytes()), string(stderr.Bytes())
|
|
||||||
klog.Errorf(program+" "+strings.Join(args, " ")+" failed: %s\nOutput:\n%s", err, stdoutStr+stderrStr)
|
|
||||||
return nil, nil, status.Error(codes.Internal, stdoutStr+stderrStr+" (status "+err.Error()+")")
|
|
||||||
}
|
|
||||||
return stdout.Bytes(), stderr.Bytes(), nil
|
|
||||||
}
|
|
||||||
|
|
||||||
func systemCombined(program string, args ...string) ([]byte, error)
|
|
||||||
{
|
|
||||||
klog.Infof("Running "+program+" "+strings.Join(args, " "))
|
|
||||||
c := exec.Command(program, args...)
|
|
||||||
var out bytes.Buffer
|
|
||||||
c.Stdout, c.Stderr = &out, &out
|
|
||||||
err := c.Run()
|
|
||||||
if (err != nil)
|
|
||||||
{
|
|
||||||
outStr := string(out.Bytes())
|
|
||||||
klog.Errorf(program+" "+strings.Join(args, " ")+" failed: %s, status %s\n", outStr, err)
|
|
||||||
return nil, status.Error(codes.Internal, outStr+" (status "+err.Error()+")")
|
|
||||||
}
|
|
||||||
return out.Bytes(), nil
|
|
||||||
}
|
|
||||||
|
|
|
@ -1,4 +1,4 @@
|
||||||
vitastor (1.10.0-1) unstable; urgency=medium
|
vitastor (1.6.1-1) unstable; urgency=medium
|
||||||
|
|
||||||
* Bugfixes
|
* Bugfixes
|
||||||
|
|
||||||
|
|
|
@ -53,9 +53,3 @@ Architecture: amd64
|
||||||
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client (= ${binary:Version})
|
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client (= ${binary:Version})
|
||||||
Description: Vitastor Proxmox Virtual Environment storage plugin
|
Description: Vitastor Proxmox Virtual Environment storage plugin
|
||||||
Vitastor storage plugin for Proxmox Virtual Environment.
|
Vitastor storage plugin for Proxmox Virtual Environment.
|
||||||
|
|
||||||
Package: vitastor-opennebula
|
|
||||||
Architecture: amd64
|
|
||||||
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client, patch, python3, jq
|
|
||||||
Description: Vitastor OpenNebula storage plugin
|
|
||||||
Vitastor storage plugin for OpenNebula.
|
|
||||||
|
|
|
@ -1,3 +1,2 @@
|
||||||
mon usr/lib/vitastor/
|
mon usr/lib/vitastor
|
||||||
mon/scripts/make-etcd usr/lib/vitastor/mon
|
mon/vitastor-mon.service /lib/systemd/system
|
||||||
mon/scripts/vitastor-mon.service /lib/systemd/system
|
|
||||||
|
|
|
@ -6,6 +6,4 @@ if [ "$1" = "configure" ]; then
|
||||||
addgroup --system --quiet vitastor
|
addgroup --system --quiet vitastor
|
||||||
adduser --system --quiet --ingroup vitastor --no-create-home --home /nonexistent vitastor
|
adduser --system --quiet --ingroup vitastor --no-create-home --home /nonexistent vitastor
|
||||||
mkdir -p /etc/vitastor
|
mkdir -p /etc/vitastor
|
||||||
mkdir -p /var/lib/vitastor
|
|
||||||
chown vitastor:vitastor /var/lib/vitastor
|
|
||||||
fi
|
fi
|
||||||
|
|
|
@ -1,3 +0,0 @@
|
||||||
opennebula/remotes var/lib/one/
|
|
||||||
opennebula/sudoers.d etc/
|
|
||||||
opennebula/install.sh var/lib/one/remotes/datastore/vitastor/
|
|
|
@ -1,7 +0,0 @@
|
||||||
#!/bin/sh
|
|
||||||
|
|
||||||
set -e
|
|
||||||
|
|
||||||
if [ "$1" = "configure" ]; then
|
|
||||||
/var/lib/one/remotes/datastore/vitastor/install.sh
|
|
||||||
fi
|
|
|
@ -1,4 +0,0 @@
|
||||||
interest /var/lib/one/remotes/datastore/downloader.sh
|
|
||||||
interest /etc/one/oned.conf
|
|
||||||
interest /etc/one/vmm_exec/vmm_execrc
|
|
||||||
interest /etc/apparmor.d/local/abstractions/libvirt-qemu
|
|
|
@ -1,6 +1,6 @@
|
||||||
usr/bin/vitastor-osd
|
usr/bin/vitastor-osd
|
||||||
usr/bin/vitastor-disk
|
usr/bin/vitastor-disk
|
||||||
usr/bin/vitastor-dump-journal
|
usr/bin/vitastor-dump-journal
|
||||||
mon/scripts/vitastor-osd@.service /lib/systemd/system
|
mon/vitastor-osd@.service /lib/systemd/system
|
||||||
mon/scripts/vitastor.target /lib/systemd/system
|
mon/vitastor.target /lib/systemd/system
|
||||||
mon/scripts/90-vitastor.rules /lib/udev/rules.d
|
mon/90-vitastor.rules /lib/udev/rules.d
|
||||||
|
|
|
@ -9,22 +9,23 @@ ARG REL=
|
||||||
|
|
||||||
WORKDIR /root
|
WORKDIR /root
|
||||||
|
|
||||||
RUN set -e -x; \
|
RUN if [ "$REL" = "buster" -o "$REL" = "bullseye" ]; then \
|
||||||
if [ "$REL" = "buster" ]; then \
|
echo "deb http://deb.debian.org/debian $REL-backports main" >> /etc/apt/sources.list; \
|
||||||
apt-get update; \
|
echo >> /etc/apt/preferences; \
|
||||||
apt-get -y install wget; \
|
echo 'Package: *' >> /etc/apt/preferences; \
|
||||||
wget https://vitastor.io/debian/pubkey.gpg -O /etc/apt/trusted.gpg.d/vitastor.gpg; \
|
echo "Pin: release a=$REL-backports" >> /etc/apt/preferences; \
|
||||||
echo "deb https://vitastor.io/debian $REL main" >> /etc/apt/sources.list; \
|
echo 'Pin-Priority: 500' >> /etc/apt/preferences; \
|
||||||
fi; \
|
fi; \
|
||||||
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
|
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
|
||||||
perl -i -pe 's/Types: deb$/Types: deb deb-src/' /etc/apt/sources.list.d/debian.sources || true; \
|
perl -i -pe 's/Types: deb$/Types: deb deb-src/' /etc/apt/sources.list.d/debian.sources || true; \
|
||||||
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
|
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
|
||||||
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
|
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
|
||||||
|
|
||||||
RUN apt-get update && \
|
RUN apt-get update
|
||||||
apt-get -y install fio liburing-dev libgoogle-perftools-dev devscripts libjerasure-dev cmake libibverbs-dev librdmacm-dev libisal-dev libnl-3-dev libnl-genl-3-dev curl && \
|
RUN apt-get -y install fio liburing-dev libgoogle-perftools-dev devscripts
|
||||||
apt-get -y build-dep fio && \
|
RUN apt-get -y build-dep fio
|
||||||
apt-get --download-only source fio
|
RUN apt-get --download-only source fio
|
||||||
|
RUN apt-get update && apt-get -y install libjerasure-dev cmake libibverbs-dev libisal-dev libnl-3-dev libnl-genl-3-dev
|
||||||
|
|
||||||
ADD . /root/vitastor
|
ADD . /root/vitastor
|
||||||
RUN set -e -x; \
|
RUN set -e -x; \
|
||||||
|
@ -36,10 +37,8 @@ RUN set -e -x; \
|
||||||
mkdir -p /root/packages/vitastor-$REL; \
|
mkdir -p /root/packages/vitastor-$REL; \
|
||||||
rm -rf /root/packages/vitastor-$REL/*; \
|
rm -rf /root/packages/vitastor-$REL/*; \
|
||||||
cd /root/packages/vitastor-$REL; \
|
cd /root/packages/vitastor-$REL; \
|
||||||
FULLVER=$(head -n1 /root/vitastor/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
cp -r /root/vitastor vitastor-1.6.1; \
|
||||||
VER=${FULLVER%%-*}; \
|
cd vitastor-1.6.1; \
|
||||||
cp -r /root/vitastor vitastor-$VER; \
|
|
||||||
cd vitastor-$VER; \
|
|
||||||
ln -s /root/fio-build/fio-*/ ./fio; \
|
ln -s /root/fio-build/fio-*/ ./fio; \
|
||||||
FIO=$(head -n1 fio/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
FIO=$(head -n1 fio/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
||||||
ls /usr/include/linux/raw.h || cp ./debian/raw.h /usr/include/linux/raw.h; \
|
ls /usr/include/linux/raw.h || cp ./debian/raw.h /usr/include/linux/raw.h; \
|
||||||
|
@ -51,14 +50,10 @@ RUN set -e -x; \
|
||||||
echo fio-headers.patch >> debian/patches/series; \
|
echo fio-headers.patch >> debian/patches/series; \
|
||||||
rm -rf a b; \
|
rm -rf a b; \
|
||||||
echo "dep:fio=$FIO" > debian/fio_version; \
|
echo "dep:fio=$FIO" > debian/fio_version; \
|
||||||
cd /root/packages/vitastor-$REL/vitastor-$VER; \
|
|
||||||
mkdir mon/node_modules; \
|
|
||||||
cd mon/node_modules; \
|
|
||||||
curl -s https://git.yourcmc.ru/vitalif/antietcd/archive/master.tar.gz | tar -zx; \
|
|
||||||
curl -s https://git.yourcmc.ru/vitalif/tinyraft/archive/master.tar.gz | tar -zx; \
|
|
||||||
cd /root/packages/vitastor-$REL; \
|
cd /root/packages/vitastor-$REL; \
|
||||||
tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_$VER.orig.tar.xz vitastor-$VER; \
|
tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_1.6.1.orig.tar.xz vitastor-1.6.1; \
|
||||||
cd vitastor-$VER; \
|
cd vitastor-1.6.1; \
|
||||||
DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v "$FULLVER""$REL" "Rebuild for $REL"; \
|
V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
|
||||||
|
DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v "$V""$REL" "Rebuild for $REL"; \
|
||||||
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \
|
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \
|
||||||
rm -rf /root/packages/vitastor-$REL/vitastor-*/
|
rm -rf /root/packages/vitastor-$REL/vitastor-*/
|
||||||
|
|
|
@ -9,7 +9,6 @@
|
||||||
These parameters apply only to Vitastor clients (QEMU, fio, NBD and so on) and
|
These parameters apply only to Vitastor clients (QEMU, fio, NBD and so on) and
|
||||||
affect their interaction with the cluster.
|
affect their interaction with the cluster.
|
||||||
|
|
||||||
- [client_iothread_count](#client_iothread_count)
|
|
||||||
- [client_retry_interval](#client_retry_interval)
|
- [client_retry_interval](#client_retry_interval)
|
||||||
- [client_eio_retry_interval](#client_eio_retry_interval)
|
- [client_eio_retry_interval](#client_eio_retry_interval)
|
||||||
- [client_retry_enospc](#client_retry_enospc)
|
- [client_retry_enospc](#client_retry_enospc)
|
||||||
|
@ -24,23 +23,6 @@ affect their interaction with the cluster.
|
||||||
- [nbd_max_part](#nbd_max_part)
|
- [nbd_max_part](#nbd_max_part)
|
||||||
- [osd_nearfull_ratio](#osd_nearfull_ratio)
|
- [osd_nearfull_ratio](#osd_nearfull_ratio)
|
||||||
|
|
||||||
## client_iothread_count
|
|
||||||
|
|
||||||
- Type: integer
|
|
||||||
- Default: 0
|
|
||||||
|
|
||||||
Number of separate threads for handling TCP network I/O at client library
|
|
||||||
side. Enabling 4 threads usually allows to increase peak performance of each
|
|
||||||
client from approx. 2-3 to 7-8 GByte/s linear read/write and from approx.
|
|
||||||
100-150 to 400 thousand iops, but at the same time it increases latency.
|
|
||||||
Latency increase depends on CPU: with CPU power saving disabled latency
|
|
||||||
only increases by ~10 us (equivalent to Q=1 iops decrease from 10500 to 9500),
|
|
||||||
with CPU power saving enabled it may be as high as 500 us (equivalent to Q=1
|
|
||||||
iops decrease from 2000 to 1000). RDMA isn't affected by this option.
|
|
||||||
|
|
||||||
It's recommended to enable client I/O threads if you don't use RDMA and want
|
|
||||||
to increase peak client performance.
|
|
||||||
|
|
||||||
## client_retry_interval
|
## client_retry_interval
|
||||||
|
|
||||||
- Type: milliseconds
|
- Type: milliseconds
|
||||||
|
|
|
@ -9,7 +9,6 @@
|
||||||
Данные параметры применяются только к клиентам Vitastor (QEMU, fio, NBD и т.п.) и
|
Данные параметры применяются только к клиентам Vitastor (QEMU, fio, NBD и т.п.) и
|
||||||
затрагивают логику их работы с кластером.
|
затрагивают логику их работы с кластером.
|
||||||
|
|
||||||
- [client_iothread_count](#client_iothread_count)
|
|
||||||
- [client_retry_interval](#client_retry_interval)
|
- [client_retry_interval](#client_retry_interval)
|
||||||
- [client_eio_retry_interval](#client_eio_retry_interval)
|
- [client_eio_retry_interval](#client_eio_retry_interval)
|
||||||
- [client_retry_enospc](#client_retry_enospc)
|
- [client_retry_enospc](#client_retry_enospc)
|
||||||
|
@ -24,24 +23,6 @@
|
||||||
- [nbd_max_part](#nbd_max_part)
|
- [nbd_max_part](#nbd_max_part)
|
||||||
- [osd_nearfull_ratio](#osd_nearfull_ratio)
|
- [osd_nearfull_ratio](#osd_nearfull_ratio)
|
||||||
|
|
||||||
## client_iothread_count
|
|
||||||
|
|
||||||
- Тип: целое число
|
|
||||||
- Значение по умолчанию: 0
|
|
||||||
|
|
||||||
Число отдельных потоков для обработки ввода-вывода через TCP сеть на стороне
|
|
||||||
клиентской библиотеки. Включение 4 потоков обычно позволяет поднять пиковую
|
|
||||||
производительность каждого клиента примерно с 2-3 до 7-8 Гбайт/с линейного
|
|
||||||
чтения/записи и примерно с 100-150 до 400 тысяч операций ввода-вывода в
|
|
||||||
секунду, но ухудшает задержку. Увеличение задержки зависит от процессора:
|
|
||||||
при отключённом энергосбережении CPU это всего ~10 микросекунд (равносильно
|
|
||||||
падению iops с Q=1 с 10500 до 9500), а при включённом это может быть
|
|
||||||
и 500 микросекунд (равносильно падению iops с Q=1 с 2000 до 1000). На работу
|
|
||||||
RDMA данная опция не влияет.
|
|
||||||
|
|
||||||
Рекомендуется включать клиентские потоки ввода-вывода, если вы не используете
|
|
||||||
RDMA и хотите повысить пиковую производительность клиентов.
|
|
||||||
|
|
||||||
## client_retry_interval
|
## client_retry_interval
|
||||||
|
|
||||||
- Тип: миллисекунды
|
- Тип: миллисекунды
|
||||||
|
|
|
@ -56,24 +56,14 @@ Can't be smaller than the OSD data device sector.
|
||||||
## immediate_commit
|
## immediate_commit
|
||||||
|
|
||||||
- Type: string
|
- Type: string
|
||||||
- Default: all
|
- Default: false
|
||||||
|
|
||||||
One of "none", "all" or "small". Global value, may be overriden [at pool level](pool.en.md#immediate_commit).
|
Another parameter which is really important for performance.
|
||||||
|
|
||||||
This parameter is also really important for performance.
|
|
||||||
|
|
||||||
TLDR: default "all" is optimal for server-grade SSDs with supercapacitor-based
|
|
||||||
power loss protection (nonvolatile write-through cache) and also for most HDDs.
|
|
||||||
"none" or "small" should be only selected if you use desktop SSDs without
|
|
||||||
capacitors or drives with slow write-back cache that can't be disabled. Check
|
|
||||||
immediate_commit of your OSDs in [ls-osd](../usage/cli.en.md#ls-osd).
|
|
||||||
|
|
||||||
Detailed explanation:
|
|
||||||
|
|
||||||
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
||||||
without cache flush. However, they are really slow (only around 1000 iops)
|
without cache flush. However, they are really slow (only around 1000 iops)
|
||||||
if you try to fsync() each write, that is, if you want to guarantee that
|
if you try to fsync() each write, that is, when you want to guarantee that
|
||||||
each change gets actually persisted to the physical media.
|
each change gets immediately persisted to the physical media.
|
||||||
|
|
||||||
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
||||||
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
||||||
|
@ -85,8 +75,8 @@ really slow when used with desktop SSDs. Vitastor, however, can also
|
||||||
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
||||||
it explicitly.
|
it explicitly.
|
||||||
|
|
||||||
This is what this parameter regulates. When it's set to "all" Vitastor
|
This is what this parameter regulates. When it's set to "all" the whole
|
||||||
cluster commits each change to disks immediately and clients just
|
Vitastor cluster commits each change to disks immediately and clients just
|
||||||
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
||||||
the amount of network roundtrips performed by clients and improves
|
the amount of network roundtrips performed by clients and improves
|
||||||
performance. So it's always better to use server grade SSDs with
|
performance. So it's always better to use server grade SSDs with
|
||||||
|
@ -106,8 +96,12 @@ SSD cache or "media-cache" - for example, a lot of Seagate EXOS drives have
|
||||||
it (they have internal SSD cache even though it's not stated in datasheets).
|
it (they have internal SSD cache even though it's not stated in datasheets).
|
||||||
|
|
||||||
Setting this parameter to "all" or "small" in OSD parameters requires enabling
|
Setting this parameter to "all" or "small" in OSD parameters requires enabling
|
||||||
[disable_journal_fsync](layout-osd.en.md#disable_journal_fsync) and
|
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
|
||||||
[disable_meta_fsync](layout-osd.en.md#disable_meta_fsync), setting it to
|
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
|
||||||
"all" also requires enabling [disable_data_fsync](layout-osd.en.md#disable_data_fsync).
|
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
|
||||||
vitastor-disk tried to do that by default, first checking/disabling drive cache.
|
|
||||||
If it can't disable drive cache, OSD get initialized with "none".
|
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
||||||
|
SSDs with supercapacitor-based power loss protection (nonvolatile
|
||||||
|
write-through cache) for both data and journals in the whole Vitastor
|
||||||
|
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
||||||
|
empty if your drives have write-back cache.
|
||||||
|
|
|
@ -57,18 +57,9 @@ amplification) и эффективность распределения нагр
|
||||||
## immediate_commit
|
## immediate_commit
|
||||||
|
|
||||||
- Тип: строка
|
- Тип: строка
|
||||||
- Значение по умолчанию: all
|
- Значение по умолчанию: false
|
||||||
|
|
||||||
Одно из значений "none", "small" или "all". Глобальное значение, может быть
|
Ещё один важный для производительности параметр.
|
||||||
переопределено [на уровне пула](pool.ru.md#immediate_commit).
|
|
||||||
|
|
||||||
Данный параметр тоже важен для производительности.
|
|
||||||
|
|
||||||
Вкратце: значение по умолчанию "all" оптимально для всех серверных SSD с
|
|
||||||
суперконденсаторами и также для большинства HDD. "none" и "small" имеет смысл
|
|
||||||
устанавливать только при использовании SSD настольного класса без
|
|
||||||
суперконденсаторов или дисков с медленным неотключаемым кэшем записи.
|
|
||||||
Проверьте настройку immediate_commit своих OSD в выводе команды [ls-osd](../usage/cli.ru.md#ls-osd).
|
|
||||||
|
|
||||||
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
||||||
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
||||||
|
@ -89,7 +80,7 @@ Power Loss Protection" - одинаково быстрые и со сбросо
|
||||||
эффективно утилизировать настольные SSD.
|
эффективно утилизировать настольные SSD.
|
||||||
|
|
||||||
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
||||||
кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||||
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
||||||
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
||||||
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
||||||
|
@ -112,6 +103,13 @@ HDD-дисках с внутренним SSD или "медиа" кэшем - н
|
||||||
указано в спецификациях).
|
указано в спецификациях).
|
||||||
|
|
||||||
Указание "all" или "small" в настройках / командной строке OSD требует
|
Указание "all" или "small" в настройках / командной строке OSD требует
|
||||||
включения [disable_journal_fsync](layout-osd.ru.md#disable_journal_fsync) и
|
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
|
||||||
[disable_meta_fsync](layout-osd.ru.md#disable_meta_fsync), значение "all"
|
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
|
||||||
также требует включения [disable_data_fsync](layout-osd.ru.md#disable_data_fsync).
|
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
|
||||||
|
|
||||||
|
Итого, вкратце: для оптимальной производительности установите
|
||||||
|
immediate_commit в значение "all", если вы используете в кластере только SSD
|
||||||
|
с суперконденсаторами и для данных, и для журналов. Если вы используете
|
||||||
|
такие SSD для всех журналов, но не для данных - можете установить параметр
|
||||||
|
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
|
||||||
|
оставьте параметр пустым.
|
||||||
|
|
|
@ -118,13 +118,12 @@ Physical block size of the journal device. Must be a multiple of
|
||||||
- Type: boolean
|
- Type: boolean
|
||||||
- Default: false
|
- Default: false
|
||||||
|
|
||||||
Do not issue fsyncs to the data device, i.e. do not force it to flush cache.
|
Do not issue fsyncs to the data device, i.e. do not flush its cache.
|
||||||
Safe ONLY if your data device has write-through cache or if write-back
|
Safe ONLY if your data device has write-through cache. If you disable
|
||||||
cache is disabled. If you disable drive cache manually with `hdparm` or
|
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure
|
||||||
writing to `/sys/.../scsi_disk/cache_type` then make sure that you do it
|
that the cache disable command is run every time before starting Vitastor
|
||||||
every time before starting Vitastor OSD (vitastor-disk does it automatically).
|
OSD, for example, in the systemd unit. See also `immediate_commit` option
|
||||||
See also [immediate_commit](layout-cluster.en.md#immediate_commit)
|
for the instructions to disable cache and how to benefit from it.
|
||||||
for information about how to benefit from disabled cache.
|
|
||||||
|
|
||||||
## disable_meta_fsync
|
## disable_meta_fsync
|
||||||
|
|
||||||
|
@ -172,7 +171,8 @@ size, it actually has to write the whole 4 KB sector.
|
||||||
|
|
||||||
Because of this it can actually be beneficial to use SSDs which work well
|
Because of this it can actually be beneficial to use SSDs which work well
|
||||||
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
|
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
|
||||||
and meta_block_size. But at the moment, no such SSDs are known...
|
and meta_block_size. But the only SSD that may fit into this category is
|
||||||
|
Intel Optane (probably, not tested yet).
|
||||||
|
|
||||||
Clients don't need to be aware of disk_alignment, so it's not required to
|
Clients don't need to be aware of disk_alignment, so it's not required to
|
||||||
put a modified value into etcd key /vitastor/config/global.
|
put a modified value into etcd key /vitastor/config/global.
|
||||||
|
|
|
@ -122,14 +122,13 @@ SSD-диске, иначе производительность пострада
|
||||||
- Тип: булево (да/нет)
|
- Тип: булево (да/нет)
|
||||||
- Значение по умолчанию: false
|
- Значение по умолчанию: false
|
||||||
|
|
||||||
Не отправлять fsync-и устройству данных, т.е. не заставлять его сбрасывать кэш.
|
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш.
|
||||||
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
|
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
|
||||||
записью (write-through) или если кэш с отложенной записью (write-back) отключён.
|
записью (write-through). Если вы отключаете кэш через `hdparm` или
|
||||||
Если вы отключаете кэш вручную через `hdparm` или запись в `/sys/.../scsi_disk/cache_type`,
|
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша
|
||||||
то удостоверьтесь, что вы делаете это каждый раз перед запуском Vitastor OSD
|
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е.
|
||||||
(vitastor-disk делает это автоматически). Смотрите также опцию
|
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша
|
||||||
[immediate_commit](layout-cluster.ru.md#immediate_commit) для информации о том,
|
и о том, как из этого извлечь выгоду.
|
||||||
как извлечь выгоду из отключённого кэша.
|
|
||||||
|
|
||||||
## disable_meta_fsync
|
## disable_meta_fsync
|
||||||
|
|
||||||
|
@ -180,8 +179,9 @@ SSD и HDD диски используют 4 КБ физические сект
|
||||||
|
|
||||||
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
|
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
|
||||||
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
|
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
|
||||||
journal_block_size и meta_block_size. Однако на данный момент такие SSD
|
journal_block_size и meta_block_size. Однако единственные SSD, которые
|
||||||
не известны...
|
теоретически могут попасть в эту категорию - это Intel Optane (но и это
|
||||||
|
пока не проверялось автором).
|
||||||
|
|
||||||
Клиентам не обязательно знать про disk_alignment, так что помещать значение
|
Клиентам не обязательно знать про disk_alignment, так что помещать значение
|
||||||
этого параметра в etcd в /vitastor/config/global не нужно.
|
этого параметра в etcd в /vitastor/config/global не нужно.
|
||||||
|
|
|
@ -8,14 +8,6 @@
|
||||||
|
|
||||||
These parameters only apply to Monitors.
|
These parameters only apply to Monitors.
|
||||||
|
|
||||||
- [use_antietcd](#use_antietcd)
|
|
||||||
- [enable_prometheus](#enable_prometheus)
|
|
||||||
- [mon_http_port](#mon_http_port)
|
|
||||||
- [mon_http_ip](#mon_http_ip)
|
|
||||||
- [mon_https_cert](#mon_https_cert)
|
|
||||||
- [mon_https_key](#mon_https_key)
|
|
||||||
- [mon_https_client_auth](#mon_https_client_auth)
|
|
||||||
- [mon_https_ca](#mon_https_ca)
|
|
||||||
- [etcd_mon_ttl](#etcd_mon_ttl)
|
- [etcd_mon_ttl](#etcd_mon_ttl)
|
||||||
- [etcd_mon_timeout](#etcd_mon_timeout)
|
- [etcd_mon_timeout](#etcd_mon_timeout)
|
||||||
- [etcd_mon_retries](#etcd_mon_retries)
|
- [etcd_mon_retries](#etcd_mon_retries)
|
||||||
|
@ -24,88 +16,6 @@ These parameters only apply to Monitors.
|
||||||
- [osd_out_time](#osd_out_time)
|
- [osd_out_time](#osd_out_time)
|
||||||
- [placement_levels](#placement_levels)
|
- [placement_levels](#placement_levels)
|
||||||
- [use_old_pg_combinator](#use_old_pg_combinator)
|
- [use_old_pg_combinator](#use_old_pg_combinator)
|
||||||
- [osd_backfillfull_ratio](#osd_backfillfull_ratio)
|
|
||||||
|
|
||||||
## use_antietcd
|
|
||||||
|
|
||||||
- Type: boolean
|
|
||||||
- Default: false
|
|
||||||
|
|
||||||
Enable experimental built-in etcd replacement (clustered key-value database):
|
|
||||||
[antietcd](https://git.yourcmc.ru/vitalif/antietcd/).
|
|
||||||
|
|
||||||
When set to true, monitor runs internal antietcd automatically if it finds
|
|
||||||
a network interface with an IP address matching one of addresses in the
|
|
||||||
`etcd_address` configuration option (in `/etc/vitastor/vitastor.conf` or in
|
|
||||||
the monitor command line). If there are multiple matching addresses, it also
|
|
||||||
checks `antietcd_port` and antietcd is started for address with matching port.
|
|
||||||
By default, antietcd accepts connection on the selected IP address, but it
|
|
||||||
can also be overridden manually in the `antietcd_ip` option.
|
|
||||||
|
|
||||||
When antietcd is started, monitor stores cluster metadata itself and exposes
|
|
||||||
a etcd-compatible REST API. On disk, these metadata are stored in
|
|
||||||
`/var/lib/vitastor/mon_2379.json.gz` (can be overridden in antietcd_data_file
|
|
||||||
or antietcd_data_dir options). All other antietcd parameters
|
|
||||||
(see [here](https://git.yourcmc.ru/vitalif/antietcd/)) except node_id,
|
|
||||||
cluster, cluster_key, persist_filter, stale_read can also be set in
|
|
||||||
Vitastor configuration with `antietcd_` prefix.
|
|
||||||
|
|
||||||
You can dump/load data to or from antietcd using Antietcd `anticli` tool:
|
|
||||||
|
|
||||||
```
|
|
||||||
npm exec anticli -e http://etcd:2379/v3 get --prefix '' --no-temp > dump.json
|
|
||||||
npm exec anticli -e http://antietcd:2379/v3 load < dump.json
|
|
||||||
```
|
|
||||||
|
|
||||||
## enable_prometheus
|
|
||||||
|
|
||||||
- Type: boolean
|
|
||||||
- Default: true
|
|
||||||
|
|
||||||
Enable built-in Prometheus metrics exporter at mon_http_port (8060 by default).
|
|
||||||
|
|
||||||
Note that only the active (master) monitor exposes metrics, others return
|
|
||||||
HTTP 503. So you should add all monitor URLs to your Prometheus job configuration.
|
|
||||||
|
|
||||||
Grafana dashboard suitable for this exporter is here: [Vitastor-Grafana-6+.json](../../mon/scripts/Vitastor-Grafana-6+.json).
|
|
||||||
|
|
||||||
## mon_http_port
|
|
||||||
|
|
||||||
- Type: integer
|
|
||||||
- Default: 8060
|
|
||||||
|
|
||||||
HTTP port for monitors to listen on (including metrics exporter)
|
|
||||||
|
|
||||||
## mon_http_ip
|
|
||||||
|
|
||||||
- Type: string
|
|
||||||
|
|
||||||
IP address for monitors to listen on (all addresses by default)
|
|
||||||
|
|
||||||
## mon_https_cert
|
|
||||||
|
|
||||||
- Type: string
|
|
||||||
|
|
||||||
Path to PEM SSL certificate file for monitor to listen using HTTPS
|
|
||||||
|
|
||||||
## mon_https_key
|
|
||||||
|
|
||||||
- Type: string
|
|
||||||
|
|
||||||
Path to PEM SSL private key file for monitor to listen using HTTPS
|
|
||||||
|
|
||||||
## mon_https_client_auth
|
|
||||||
|
|
||||||
- Type: boolean
|
|
||||||
- Default: false
|
|
||||||
|
|
||||||
Enable HTTPS client certificate-based authorization for monitor connections
|
|
||||||
|
|
||||||
## mon_https_ca
|
|
||||||
|
|
||||||
- Type: string
|
|
||||||
|
|
||||||
Path to CA certificate for client HTTPS authorization
|
|
||||||
|
|
||||||
## etcd_mon_ttl
|
## etcd_mon_ttl
|
||||||
|
|
||||||
|
@ -176,18 +86,3 @@ present in the configuration, then it is defined with the default priority
|
||||||
|
|
||||||
Use the old PG combination generator which doesn't support [level_placement](pool.en.md#level_placement)
|
Use the old PG combination generator which doesn't support [level_placement](pool.en.md#level_placement)
|
||||||
and [raw_placement](pool.en.md#raw_placement) for pools which don't use this features.
|
and [raw_placement](pool.en.md#raw_placement) for pools which don't use this features.
|
||||||
|
|
||||||
## osd_backfillfull_ratio
|
|
||||||
|
|
||||||
- Type: number
|
|
||||||
- Default: 0.99
|
|
||||||
|
|
||||||
Monitors try to prevent OSDs becoming 100% full during rebalance or recovery by
|
|
||||||
calculating how much space will be occupied on every OSD after all rebalance
|
|
||||||
and recovery operations finish, and pausing rebalance and recovery if that
|
|
||||||
amount of space exceeds OSD capacity multiplied by the value of this
|
|
||||||
configuration parameter.
|
|
||||||
|
|
||||||
Future used space is calculated by summing space used by all user data blocks
|
|
||||||
(objects) in all PGs placed on a specific OSD, even if some of these objects
|
|
||||||
currently reside on a different set of OSDs.
|
|
||||||
|
|
|
@ -8,14 +8,6 @@
|
||||||
|
|
||||||
Данные параметры используются только мониторами Vitastor.
|
Данные параметры используются только мониторами Vitastor.
|
||||||
|
|
||||||
- [use_antietcd](#use_antietcd)
|
|
||||||
- [enable_prometheus](#enable_prometheus)
|
|
||||||
- [mon_http_port](#mon_http_port)
|
|
||||||
- [mon_http_ip](#mon_http_ip)
|
|
||||||
- [mon_https_cert](#mon_https_cert)
|
|
||||||
- [mon_https_key](#mon_https_key)
|
|
||||||
- [mon_https_client_auth](#mon_https_client_auth)
|
|
||||||
- [mon_https_ca](#mon_https_ca)
|
|
||||||
- [etcd_mon_ttl](#etcd_mon_ttl)
|
- [etcd_mon_ttl](#etcd_mon_ttl)
|
||||||
- [etcd_mon_timeout](#etcd_mon_timeout)
|
- [etcd_mon_timeout](#etcd_mon_timeout)
|
||||||
- [etcd_mon_retries](#etcd_mon_retries)
|
- [etcd_mon_retries](#etcd_mon_retries)
|
||||||
|
@ -24,90 +16,6 @@
|
||||||
- [osd_out_time](#osd_out_time)
|
- [osd_out_time](#osd_out_time)
|
||||||
- [placement_levels](#placement_levels)
|
- [placement_levels](#placement_levels)
|
||||||
- [use_old_pg_combinator](#use_old_pg_combinator)
|
- [use_old_pg_combinator](#use_old_pg_combinator)
|
||||||
- [osd_backfillfull_ratio](#osd_backfillfull_ratio)
|
|
||||||
|
|
||||||
## use_antietcd
|
|
||||||
|
|
||||||
- Тип: булево (да/нет)
|
|
||||||
- Значение по умолчанию: false
|
|
||||||
|
|
||||||
Включить экспериментальный встроенный заменитель etcd (кластерную БД ключ-значение):
|
|
||||||
[antietcd](https://git.yourcmc.ru/vitalif/antietcd/).
|
|
||||||
|
|
||||||
Если параметр установлен в true, монитор запускает antietcd автоматически,
|
|
||||||
если обнаруживает сетевой интерфейс с одним из адресов, указанных в опции
|
|
||||||
конфигурации `etcd_address` (в `/etc/vitastor/vitastor.conf` или в опциях
|
|
||||||
командной строки монитора). Если таких адресов несколько, также проверяется
|
|
||||||
опция `antietcd_port` и antietcd запускается для адреса с соответствующим
|
|
||||||
портом. По умолчанию antietcd принимает подключения по выбранному совпадающему
|
|
||||||
IP, но его также можно определить вручную опцией `antietcd_ip`.
|
|
||||||
|
|
||||||
При запуске antietcd монитор сам хранит центральные метаданные кластера и
|
|
||||||
выставляет etcd-совместимое REST API. На диске эти метаданные хранятся в файле
|
|
||||||
`/var/lib/vitastor/mon_2379.json.gz` (можно переопределить параметрами
|
|
||||||
antietcd_data_file или antietcd_data_dir). Все остальные параметры antietcd
|
|
||||||
(смотрите [по ссылке](https://git.yourcmc.ru/vitalif/antietcd/)), за исключением
|
|
||||||
node_id, cluster, cluster_key, persist_filter, stale_read также можно задавать
|
|
||||||
в конфигурации Vitastor с префиксом `antietcd_`.
|
|
||||||
|
|
||||||
Вы можете выгружать/загружать данные в или из antietcd с помощью его инструмента
|
|
||||||
`anticli`:
|
|
||||||
|
|
||||||
```
|
|
||||||
npm exec anticli -e http://etcd:2379/v3 get --prefix '' --no-temp > dump.json
|
|
||||||
npm exec anticli -e http://antietcd:2379/v3 load < dump.json
|
|
||||||
```
|
|
||||||
|
|
||||||
## enable_prometheus
|
|
||||||
|
|
||||||
- Тип: булево (да/нет)
|
|
||||||
- Значение по умолчанию: true
|
|
||||||
|
|
||||||
Включить встроенный Prometheus-экспортер метрик на порту mon_http_port (по умолчанию 8060).
|
|
||||||
|
|
||||||
Обратите внимание, что метрики выставляет только активный (главный) монитор, остальные
|
|
||||||
возвращают статус HTTP 503, поэтому вам следует добавлять адреса всех мониторов
|
|
||||||
в задание по сбору метрик Prometheus.
|
|
||||||
|
|
||||||
Дашборд для Grafana, подходящий для этого экспортера: [Vitastor-Grafana-6+.json](../../mon/scripts/Vitastor-Grafana-6+.json).
|
|
||||||
|
|
||||||
## mon_http_port
|
|
||||||
|
|
||||||
- Тип: целое число
|
|
||||||
- Значение по умолчанию: 8060
|
|
||||||
|
|
||||||
Порт, на котором мониторы принимают HTTP-соединения (в том числе для отдачи метрик)
|
|
||||||
|
|
||||||
## mon_http_ip
|
|
||||||
|
|
||||||
- Тип: строка
|
|
||||||
|
|
||||||
IP-адрес, на котором мониторы принимают HTTP-соединения (по умолчанию все адреса)
|
|
||||||
|
|
||||||
## mon_https_cert
|
|
||||||
|
|
||||||
- Тип: строка
|
|
||||||
|
|
||||||
Путь к PEM-файлу SSL-сертификата для монитора, чтобы принимать соединения через HTTPS
|
|
||||||
|
|
||||||
## mon_https_key
|
|
||||||
|
|
||||||
- Тип: строка
|
|
||||||
|
|
||||||
Путь к PEM-файлу секретного SSL-ключа для монитора, чтобы принимать соединения через HTTPS
|
|
||||||
|
|
||||||
## mon_https_client_auth
|
|
||||||
|
|
||||||
- Тип: булево (да/нет)
|
|
||||||
- Значение по умолчанию: false
|
|
||||||
|
|
||||||
Включить в HTTPS-сервере монитора авторизацию по клиентским сертификатам
|
|
||||||
|
|
||||||
## mon_https_ca
|
|
||||||
|
|
||||||
- Тип: строка
|
|
||||||
|
|
||||||
Путь к удостоверяющему сертификату для авторизации клиентских HTTPS соединений
|
|
||||||
|
|
||||||
## etcd_mon_ttl
|
## etcd_mon_ttl
|
||||||
|
|
||||||
|
@ -179,19 +87,3 @@ OSD перед обновлением агрегированной статис
|
||||||
|
|
||||||
Использовать старый генератор комбинаций PG, не поддерживающий [level_placement](pool.ru.md#level_placement)
|
Использовать старый генератор комбинаций PG, не поддерживающий [level_placement](pool.ru.md#level_placement)
|
||||||
и [raw_placement](pool.ru.md#raw_placement) для пулов, которые не используют данные функции.
|
и [raw_placement](pool.ru.md#raw_placement) для пулов, которые не используют данные функции.
|
||||||
|
|
||||||
## osd_backfillfull_ratio
|
|
||||||
|
|
||||||
- Тип: число
|
|
||||||
- Значение по умолчанию: 0.99
|
|
||||||
|
|
||||||
Мониторы стараются предотвратить 100% заполнение OSD в процессе ребаланса
|
|
||||||
или восстановления, рассчитывая, сколько места будет занято на каждом OSD после
|
|
||||||
завершения всех операций ребаланса и восстановления, и приостанавливая
|
|
||||||
ребаланс и восстановление, если рассчитанный объём превышает ёмкость OSD,
|
|
||||||
умноженную на значение данного параметра.
|
|
||||||
|
|
||||||
Будущее занятое место рассчитывается сложением места, занятого всеми
|
|
||||||
пользовательскими блоками данных (объектами) во всех PG, расположенных
|
|
||||||
на конкретном OSD, даже если часть этих объектов в данный момент находится
|
|
||||||
на другом наборе OSD.
|
|
||||||
|
|
|
@ -68,17 +68,11 @@ but they are not connected to the cluster.
|
||||||
- Type: string
|
- Type: string
|
||||||
|
|
||||||
RDMA device name to use for Vitastor OSD communications (for example,
|
RDMA device name to use for Vitastor OSD communications (for example,
|
||||||
"rocep5s0f0"). If not specified, Vitastor will try to find an RoCE
|
"rocep5s0f0"). Now Vitastor supports all adapters, even ones without
|
||||||
device matching [osd_network](osd.en.md#osd_network), preferring RoCEv2,
|
ODP support, like Mellanox ConnectX-3 and non-Mellanox cards.
|
||||||
or choose the first available RDMA device if no RoCE devices are
|
|
||||||
found or if `osd_network` is not specified. Auto-selection is also
|
|
||||||
unsupported with old libibverbs < v32, like in Debian 10 Buster or
|
|
||||||
CentOS 7.
|
|
||||||
|
|
||||||
Vitastor supports all adapters, even ones without ODP support, like
|
Versions up to Vitastor 1.2.0 required ODP which is only present in
|
||||||
Mellanox ConnectX-3 and non-Mellanox cards. Versions up to Vitastor
|
Mellanox ConnectX >= 4. See also [rdma_odp](#rdma_odp).
|
||||||
1.2.0 required ODP which is only present in Mellanox ConnectX >= 4.
|
|
||||||
See also [rdma_odp](#rdma_odp).
|
|
||||||
|
|
||||||
Run `ibv_devinfo -v` as root to list available RDMA devices and their
|
Run `ibv_devinfo -v` as root to list available RDMA devices and their
|
||||||
features.
|
features.
|
||||||
|
@ -101,17 +95,15 @@ your device has.
|
||||||
## rdma_gid_index
|
## rdma_gid_index
|
||||||
|
|
||||||
- Type: integer
|
- Type: integer
|
||||||
|
- Default: 0
|
||||||
|
|
||||||
Global address identifier index of the RDMA device to use. Different GID
|
Global address identifier index of the RDMA device to use. Different GID
|
||||||
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
|
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
|
||||||
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
|
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
|
||||||
you need.
|
you need.
|
||||||
|
|
||||||
If not specified, Vitastor will try to auto-select a RoCEv2 IPv4 GID, then
|
**IMPORTANT:** If you want to use RoCEv2 (as recommended) then the correct
|
||||||
RoCEv2 IPv6 GID, then RoCEv1 IPv4 GID, then RoCEv1 IPv6 GID, then IB GID.
|
rdma_gid_index is usually 1 (IPv6) or 3 (IPv4).
|
||||||
GID auto-selection is unsupported with libibverbs < v32.
|
|
||||||
|
|
||||||
A correct rdma_gid_index for RoCEv2 is usually 1 (IPv6) or 3 (IPv4).
|
|
||||||
|
|
||||||
## rdma_mtu
|
## rdma_mtu
|
||||||
|
|
||||||
|
@ -256,7 +248,7 @@ etcd_report_interval to guarantee that keepalive actually works.
|
||||||
## etcd_ws_keepalive_interval
|
## etcd_ws_keepalive_interval
|
||||||
|
|
||||||
- Type: seconds
|
- Type: seconds
|
||||||
- Default: 5
|
- Default: 30
|
||||||
- Can be changed online: yes
|
- Can be changed online: yes
|
||||||
|
|
||||||
etcd websocket ping interval required to keep the connection alive and
|
etcd websocket ping interval required to keep the connection alive and
|
||||||
|
|
|
@ -71,17 +71,12 @@ RDMA может быть нужно только если у клиентов е
|
||||||
- Тип: строка
|
- Тип: строка
|
||||||
|
|
||||||
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
|
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
|
||||||
Если не указано, Vitastor попробует найти RoCE-устройство, соответствующее
|
Сейчас Vitastor поддерживает все модели адаптеров, включая те, у которых
|
||||||
[osd_network](osd.en.md#osd_network), предпочитая RoCEv2, или выбрать первое
|
|
||||||
попавшееся RDMA-устройство, если RoCE-устройств нет или если сеть `osd_network`
|
|
||||||
не задана. Также автовыбор не поддерживается со старыми версиями библиотеки
|
|
||||||
libibverbs < v32, например в Debian 10 Buster или CentOS 7.
|
|
||||||
|
|
||||||
Vitastor поддерживает все модели адаптеров, включая те, у которых
|
|
||||||
нет поддержки ODP, то есть вы можете использовать RDMA с ConnectX-3 и
|
нет поддержки ODP, то есть вы можете использовать RDMA с ConnectX-3 и
|
||||||
картами производства не Mellanox. Версии Vitastor до 1.2.0 включительно
|
картами производства не Mellanox.
|
||||||
требовали ODP, который есть только на Mellanox ConnectX 4 и более новых.
|
|
||||||
См. также [rdma_odp](#rdma_odp).
|
Версии Vitastor до 1.2.0 включительно требовали ODP, который есть только
|
||||||
|
на Mellanox ConnectX 4 и более новых. См. также [rdma_odp](#rdma_odp).
|
||||||
|
|
||||||
Запустите `ibv_devinfo -v` от имени суперпользователя, чтобы посмотреть
|
Запустите `ibv_devinfo -v` от имени суперпользователя, чтобы посмотреть
|
||||||
список доступных RDMA-устройств, их параметры и возможности.
|
список доступных RDMA-устройств, их параметры и возможности.
|
||||||
|
@ -106,18 +101,15 @@ Control) и ECN (Explicit Congestion Notification).
|
||||||
## rdma_gid_index
|
## rdma_gid_index
|
||||||
|
|
||||||
- Тип: целое число
|
- Тип: целое число
|
||||||
|
- Значение по умолчанию: 0
|
||||||
|
|
||||||
Номер глобального идентификатора адреса RDMA-устройства, который следует
|
Номер глобального идентификатора адреса RDMA-устройства, который следует
|
||||||
использовать. Разным gid_index могут соответствовать разные протоколы связи:
|
использовать. Разным gid_index могут соответствовать разные протоколы связи:
|
||||||
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
|
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
|
||||||
словом "GID" в выводе команды `ibv_devinfo -v`.
|
словом "GID" в выводе команды `ibv_devinfo -v`.
|
||||||
|
|
||||||
Если не указан, Vitastor попробует автоматически выбрать сначала GID,
|
**ВАЖНО:** Если вы хотите использовать RoCEv2 (как мы и рекомендуем), то
|
||||||
соответствующий RoCEv2 IPv4, потом RoCEv2 IPv6, потом RoCEv1 IPv4, потом
|
правильный rdma_gid_index, как правило, 1 (IPv6) или 3 (IPv4).
|
||||||
RoCEv1 IPv6, потом IB. Авто-выбор GID не поддерживается со старыми версиями
|
|
||||||
libibverbs < v32.
|
|
||||||
|
|
||||||
Правильный rdma_gid_index для RoCEv2, как правило, 1 (IPv6) или 3 (IPv4).
|
|
||||||
|
|
||||||
## rdma_mtu
|
## rdma_mtu
|
||||||
|
|
||||||
|
@ -267,7 +259,7 @@ etcd_report_interval, чтобы keepalive гарантированно рабо
|
||||||
## etcd_ws_keepalive_interval
|
## etcd_ws_keepalive_interval
|
||||||
|
|
||||||
- Тип: секунды
|
- Тип: секунды
|
||||||
- Значение по умолчанию: 5
|
- Значение по умолчанию: 30
|
||||||
- Можно менять на лету: да
|
- Можно менять на лету: да
|
||||||
|
|
||||||
Интервал проверки живости вебсокет-подключений к etcd.
|
Интервал проверки живости вебсокет-подключений к etcd.
|
||||||
|
|
|
@ -10,7 +10,6 @@ These parameters only apply to OSDs, are not fixed at the moment of OSD drive
|
||||||
initialization and can be changed - either with an OSD restart or, for some of
|
initialization and can be changed - either with an OSD restart or, for some of
|
||||||
them, even without restarting by updating configuration in etcd.
|
them, even without restarting by updating configuration in etcd.
|
||||||
|
|
||||||
- [osd_iothread_count](#osd_iothread_count)
|
|
||||||
- [etcd_report_interval](#etcd_report_interval)
|
- [etcd_report_interval](#etcd_report_interval)
|
||||||
- [etcd_stats_interval](#etcd_stats_interval)
|
- [etcd_stats_interval](#etcd_stats_interval)
|
||||||
- [run_primary](#run_primary)
|
- [run_primary](#run_primary)
|
||||||
|
@ -62,18 +61,6 @@ them, even without restarting by updating configuration in etcd.
|
||||||
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
|
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
|
||||||
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
|
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
|
||||||
|
|
||||||
## osd_iothread_count
|
|
||||||
|
|
||||||
- Type: integer
|
|
||||||
- Default: 0
|
|
||||||
|
|
||||||
TCP network I/O thread count for OSD. When non-zero, a single OSD process
|
|
||||||
may handle more TCP I/O, but at a cost of increased latency because thread
|
|
||||||
switching overhead occurs. RDMA isn't affected by this option.
|
|
||||||
|
|
||||||
Because of latency, instead of enabling OSD I/O threads it's recommended to
|
|
||||||
just create multiple OSDs per disk, or use RDMA.
|
|
||||||
|
|
||||||
## etcd_report_interval
|
## etcd_report_interval
|
||||||
|
|
||||||
- Type: seconds
|
- Type: seconds
|
||||||
|
|
|
@ -11,7 +11,6 @@
|
||||||
момент с помощью перезапуска OSD, а некоторые и без перезапуска, с помощью
|
момент с помощью перезапуска OSD, а некоторые и без перезапуска, с помощью
|
||||||
изменения конфигурации в etcd.
|
изменения конфигурации в etcd.
|
||||||
|
|
||||||
- [osd_iothread_count](#osd_iothread_count)
|
|
||||||
- [etcd_report_interval](#etcd_report_interval)
|
- [etcd_report_interval](#etcd_report_interval)
|
||||||
- [etcd_stats_interval](#etcd_stats_interval)
|
- [etcd_stats_interval](#etcd_stats_interval)
|
||||||
- [run_primary](#run_primary)
|
- [run_primary](#run_primary)
|
||||||
|
@ -63,19 +62,6 @@
|
||||||
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
|
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
|
||||||
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
|
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
|
||||||
|
|
||||||
## osd_iothread_count
|
|
||||||
|
|
||||||
- Тип: целое число
|
|
||||||
- Значение по умолчанию: 0
|
|
||||||
|
|
||||||
Число отдельных потоков для обработки ввода-вывода через TCP-сеть на
|
|
||||||
стороне OSD. Включение опции позволяет каждому отдельному OSD передавать
|
|
||||||
по сети больше данных, но ухудшает задержку из-за накладных расходов
|
|
||||||
переключения потоков. На работу RDMA опция не влияет.
|
|
||||||
|
|
||||||
Из-за задержек вместо включения потоков ввода-вывода OSD рекомендуется
|
|
||||||
просто создавать по несколько OSD на каждом диске, или использовать RDMA.
|
|
||||||
|
|
||||||
## etcd_report_interval
|
## etcd_report_interval
|
||||||
|
|
||||||
- Тип: секунды
|
- Тип: секунды
|
||||||
|
|
|
@ -55,7 +55,7 @@ Examples:
|
||||||
OSD placement tree is set in a separate etcd key `/vitastor/config/node_placement`
|
OSD placement tree is set in a separate etcd key `/vitastor/config/node_placement`
|
||||||
in the following JSON format:
|
in the following JSON format:
|
||||||
|
|
||||||
```
|
`
|
||||||
{
|
{
|
||||||
"<node name or OSD number>": {
|
"<node name or OSD number>": {
|
||||||
"level": "<level>",
|
"level": "<level>",
|
||||||
|
@ -63,7 +63,7 @@ in the following JSON format:
|
||||||
},
|
},
|
||||||
...
|
...
|
||||||
}
|
}
|
||||||
```
|
`
|
||||||
|
|
||||||
Here, if a node name is a number then it is assumed to refer to an OSD.
|
Here, if a node name is a number then it is assumed to refer to an OSD.
|
||||||
Level of the OSD is always "osd" and cannot be overriden. You may only
|
Level of the OSD is always "osd" and cannot be overriden. You may only
|
||||||
|
|
|
@ -54,7 +54,7 @@
|
||||||
Дерево размещения OSD задаётся в отдельном ключе etcd `/vitastor/config/node_placement`
|
Дерево размещения OSD задаётся в отдельном ключе etcd `/vitastor/config/node_placement`
|
||||||
в следующем JSON-формате:
|
в следующем JSON-формате:
|
||||||
|
|
||||||
```
|
`
|
||||||
{
|
{
|
||||||
"<имя узла или номер OSD>": {
|
"<имя узла или номер OSD>": {
|
||||||
"level": "<уровень>",
|
"level": "<уровень>",
|
||||||
|
@ -62,7 +62,7 @@
|
||||||
},
|
},
|
||||||
...
|
...
|
||||||
}
|
}
|
||||||
```
|
`
|
||||||
|
|
||||||
Здесь, если название узла - число, считается, что это OSD. Уровень OSD
|
Здесь, если название узла - число, считается, что это OSD. Уровень OSD
|
||||||
всегда равен "osd" и не может быть переопределён. Для OSD вы можете только
|
всегда равен "osd" и не может быть переопределён. Для OSD вы можете только
|
||||||
|
|
|
@ -1,32 +1,3 @@
|
||||||
- name: client_iothread_count
|
|
||||||
type: int
|
|
||||||
default: 0
|
|
||||||
online: false
|
|
||||||
info: |
|
|
||||||
Number of separate threads for handling TCP network I/O at client library
|
|
||||||
side. Enabling 4 threads usually allows to increase peak performance of each
|
|
||||||
client from approx. 2-3 to 7-8 GByte/s linear read/write and from approx.
|
|
||||||
100-150 to 400 thousand iops, but at the same time it increases latency.
|
|
||||||
Latency increase depends on CPU: with CPU power saving disabled latency
|
|
||||||
only increases by ~10 us (equivalent to Q=1 iops decrease from 10500 to 9500),
|
|
||||||
with CPU power saving enabled it may be as high as 500 us (equivalent to Q=1
|
|
||||||
iops decrease from 2000 to 1000). RDMA isn't affected by this option.
|
|
||||||
|
|
||||||
It's recommended to enable client I/O threads if you don't use RDMA and want
|
|
||||||
to increase peak client performance.
|
|
||||||
info_ru: |
|
|
||||||
Число отдельных потоков для обработки ввода-вывода через TCP сеть на стороне
|
|
||||||
клиентской библиотеки. Включение 4 потоков обычно позволяет поднять пиковую
|
|
||||||
производительность каждого клиента примерно с 2-3 до 7-8 Гбайт/с линейного
|
|
||||||
чтения/записи и примерно с 100-150 до 400 тысяч операций ввода-вывода в
|
|
||||||
секунду, но ухудшает задержку. Увеличение задержки зависит от процессора:
|
|
||||||
при отключённом энергосбережении CPU это всего ~10 микросекунд (равносильно
|
|
||||||
падению iops с Q=1 с 10500 до 9500), а при включённом это может быть
|
|
||||||
и 500 микросекунд (равносильно падению iops с Q=1 с 2000 до 1000). На работу
|
|
||||||
RDMA данная опция не влияет.
|
|
||||||
|
|
||||||
Рекомендуется включать клиентские потоки ввода-вывода, если вы не используете
|
|
||||||
RDMA и хотите повысить пиковую производительность клиентов.
|
|
||||||
- name: client_retry_interval
|
- name: client_retry_interval
|
||||||
type: ms
|
type: ms
|
||||||
min: 10
|
min: 10
|
||||||
|
|
|
@ -47,24 +47,14 @@
|
||||||
Не может быть меньше размера сектора дисков данных OSD.
|
Не может быть меньше размера сектора дисков данных OSD.
|
||||||
- name: immediate_commit
|
- name: immediate_commit
|
||||||
type: string
|
type: string
|
||||||
default: all
|
default: false
|
||||||
info: |
|
info: |
|
||||||
One of "none", "all" or "small". Global value, may be overriden [at pool level](pool.en.md#immediate_commit).
|
Another parameter which is really important for performance.
|
||||||
|
|
||||||
This parameter is also really important for performance.
|
|
||||||
|
|
||||||
TLDR: default "all" is optimal for server-grade SSDs with supercapacitor-based
|
|
||||||
power loss protection (nonvolatile write-through cache) and also for most HDDs.
|
|
||||||
"none" or "small" should be only selected if you use desktop SSDs without
|
|
||||||
capacitors or drives with slow write-back cache that can't be disabled. Check
|
|
||||||
immediate_commit of your OSDs in [ls-osd](../usage/cli.en.md#ls-osd).
|
|
||||||
|
|
||||||
Detailed explanation:
|
|
||||||
|
|
||||||
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
||||||
without cache flush. However, they are really slow (only around 1000 iops)
|
without cache flush. However, they are really slow (only around 1000 iops)
|
||||||
if you try to fsync() each write, that is, if you want to guarantee that
|
if you try to fsync() each write, that is, when you want to guarantee that
|
||||||
each change gets actually persisted to the physical media.
|
each change gets immediately persisted to the physical media.
|
||||||
|
|
||||||
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
||||||
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
||||||
|
@ -76,8 +66,8 @@
|
||||||
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
||||||
it explicitly.
|
it explicitly.
|
||||||
|
|
||||||
This is what this parameter regulates. When it's set to "all" Vitastor
|
This is what this parameter regulates. When it's set to "all" the whole
|
||||||
cluster commits each change to disks immediately and clients just
|
Vitastor cluster commits each change to disks immediately and clients just
|
||||||
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
||||||
the amount of network roundtrips performed by clients and improves
|
the amount of network roundtrips performed by clients and improves
|
||||||
performance. So it's always better to use server grade SSDs with
|
performance. So it's always better to use server grade SSDs with
|
||||||
|
@ -97,22 +87,17 @@
|
||||||
it (they have internal SSD cache even though it's not stated in datasheets).
|
it (they have internal SSD cache even though it's not stated in datasheets).
|
||||||
|
|
||||||
Setting this parameter to "all" or "small" in OSD parameters requires enabling
|
Setting this parameter to "all" or "small" in OSD parameters requires enabling
|
||||||
[disable_journal_fsync](layout-osd.en.md#disable_journal_fsync) and
|
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
|
||||||
[disable_meta_fsync](layout-osd.en.md#disable_meta_fsync), setting it to
|
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
|
||||||
"all" also requires enabling [disable_data_fsync](layout-osd.en.md#disable_data_fsync).
|
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
|
||||||
vitastor-disk tried to do that by default, first checking/disabling drive cache.
|
|
||||||
If it can't disable drive cache, OSD get initialized with "none".
|
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
||||||
|
SSDs with supercapacitor-based power loss protection (nonvolatile
|
||||||
|
write-through cache) for both data and journals in the whole Vitastor
|
||||||
|
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
||||||
|
empty if your drives have write-back cache.
|
||||||
info_ru: |
|
info_ru: |
|
||||||
Одно из значений "none", "small" или "all". Глобальное значение, может быть
|
Ещё один важный для производительности параметр.
|
||||||
переопределено [на уровне пула](pool.ru.md#immediate_commit).
|
|
||||||
|
|
||||||
Данный параметр тоже важен для производительности.
|
|
||||||
|
|
||||||
Вкратце: значение по умолчанию "all" оптимально для всех серверных SSD с
|
|
||||||
суперконденсаторами и также для большинства HDD. "none" и "small" имеет смысл
|
|
||||||
устанавливать только при использовании SSD настольного класса без
|
|
||||||
суперконденсаторов или дисков с медленным неотключаемым кэшем записи.
|
|
||||||
Проверьте настройку immediate_commit своих OSD в выводе команды [ls-osd](../usage/cli.ru.md#ls-osd).
|
|
||||||
|
|
||||||
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
|
||||||
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
секунду) при простой случайной записи без сбросов кэша. Однако они очень
|
||||||
|
@ -133,7 +118,7 @@
|
||||||
эффективно утилизировать настольные SSD.
|
эффективно утилизировать настольные SSD.
|
||||||
|
|
||||||
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
|
||||||
кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
|
||||||
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
|
||||||
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
|
||||||
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
|
||||||
|
@ -156,6 +141,13 @@
|
||||||
указано в спецификациях).
|
указано в спецификациях).
|
||||||
|
|
||||||
Указание "all" или "small" в настройках / командной строке OSD требует
|
Указание "all" или "small" в настройках / командной строке OSD требует
|
||||||
включения [disable_journal_fsync](layout-osd.ru.md#disable_journal_fsync) и
|
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
|
||||||
[disable_meta_fsync](layout-osd.ru.md#disable_meta_fsync), значение "all"
|
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
|
||||||
также требует включения [disable_data_fsync](layout-osd.ru.md#disable_data_fsync).
|
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
|
||||||
|
|
||||||
|
Итого, вкратце: для оптимальной производительности установите
|
||||||
|
immediate_commit в значение "all", если вы используете в кластере только SSD
|
||||||
|
с суперконденсаторами и для данных, и для журналов. Если вы используете
|
||||||
|
такие SSD для всех журналов, но не для данных - можете установить параметр
|
||||||
|
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
|
||||||
|
оставьте параметр пустым.
|
||||||
|
|
|
@ -110,22 +110,20 @@
|
||||||
type: bool
|
type: bool
|
||||||
default: false
|
default: false
|
||||||
info: |
|
info: |
|
||||||
Do not issue fsyncs to the data device, i.e. do not force it to flush cache.
|
Do not issue fsyncs to the data device, i.e. do not flush its cache.
|
||||||
Safe ONLY if your data device has write-through cache or if write-back
|
Safe ONLY if your data device has write-through cache. If you disable
|
||||||
cache is disabled. If you disable drive cache manually with `hdparm` or
|
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure
|
||||||
writing to `/sys/.../scsi_disk/cache_type` then make sure that you do it
|
that the cache disable command is run every time before starting Vitastor
|
||||||
every time before starting Vitastor OSD (vitastor-disk does it automatically).
|
OSD, for example, in the systemd unit. See also `immediate_commit` option
|
||||||
See also [immediate_commit](layout-cluster.en.md#immediate_commit)
|
for the instructions to disable cache and how to benefit from it.
|
||||||
for information about how to benefit from disabled cache.
|
|
||||||
info_ru: |
|
info_ru: |
|
||||||
Не отправлять fsync-и устройству данных, т.е. не заставлять его сбрасывать кэш.
|
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш.
|
||||||
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
|
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
|
||||||
записью (write-through) или если кэш с отложенной записью (write-back) отключён.
|
записью (write-through). Если вы отключаете кэш через `hdparm` или
|
||||||
Если вы отключаете кэш вручную через `hdparm` или запись в `/sys/.../scsi_disk/cache_type`,
|
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша
|
||||||
то удостоверьтесь, что вы делаете это каждый раз перед запуском Vitastor OSD
|
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е.
|
||||||
(vitastor-disk делает это автоматически). Смотрите также опцию
|
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша
|
||||||
[immediate_commit](layout-cluster.ru.md#immediate_commit) для информации о том,
|
и о том, как из этого извлечь выгоду.
|
||||||
как извлечь выгоду из отключённого кэша.
|
|
||||||
- name: disable_meta_fsync
|
- name: disable_meta_fsync
|
||||||
type: bool
|
type: bool
|
||||||
default: false
|
default: false
|
||||||
|
@ -181,7 +179,8 @@
|
||||||
|
|
||||||
Because of this it can actually be beneficial to use SSDs which work well
|
Because of this it can actually be beneficial to use SSDs which work well
|
||||||
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
|
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
|
||||||
and meta_block_size. But at the moment, no such SSDs are known...
|
and meta_block_size. But the only SSD that may fit into this category is
|
||||||
|
Intel Optane (probably, not tested yet).
|
||||||
|
|
||||||
Clients don't need to be aware of disk_alignment, so it's not required to
|
Clients don't need to be aware of disk_alignment, so it's not required to
|
||||||
put a modified value into etcd key /vitastor/config/global.
|
put a modified value into etcd key /vitastor/config/global.
|
||||||
|
@ -199,8 +198,9 @@
|
||||||
|
|
||||||
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
|
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
|
||||||
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
|
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
|
||||||
journal_block_size и meta_block_size. Однако на данный момент такие SSD
|
journal_block_size и meta_block_size. Однако единственные SSD, которые
|
||||||
не известны...
|
теоретически могут попасть в эту категорию - это Intel Optane (но и это
|
||||||
|
пока не проверялось автором).
|
||||||
|
|
||||||
Клиентам не обязательно знать про disk_alignment, так что помещать значение
|
Клиентам не обязательно знать про disk_alignment, так что помещать значение
|
||||||
этого параметра в etcd в /vitastor/config/global не нужно.
|
этого параметра в etcd в /vitastor/config/global не нужно.
|
||||||
|
|
|
@ -1,103 +1,3 @@
|
||||||
- name: use_antietcd
|
|
||||||
type: bool
|
|
||||||
default: false
|
|
||||||
info: |
|
|
||||||
Enable experimental built-in etcd replacement (clustered key-value database):
|
|
||||||
[antietcd](https://git.yourcmc.ru/vitalif/antietcd/).
|
|
||||||
|
|
||||||
When set to true, monitor runs internal antietcd automatically if it finds
|
|
||||||
a network interface with an IP address matching one of addresses in the
|
|
||||||
`etcd_address` configuration option (in `/etc/vitastor/vitastor.conf` or in
|
|
||||||
the monitor command line). If there are multiple matching addresses, it also
|
|
||||||
checks `antietcd_port` and antietcd is started for address with matching port.
|
|
||||||
By default, antietcd accepts connection on the selected IP address, but it
|
|
||||||
can also be overridden manually in the `antietcd_ip` option.
|
|
||||||
|
|
||||||
When antietcd is started, monitor stores cluster metadata itself and exposes
|
|
||||||
a etcd-compatible REST API. On disk, these metadata are stored in
|
|
||||||
`/var/lib/vitastor/mon_2379.json.gz` (can be overridden in antietcd_data_file
|
|
||||||
or antietcd_data_dir options). All other antietcd parameters
|
|
||||||
(see [here](https://git.yourcmc.ru/vitalif/antietcd/)) except node_id,
|
|
||||||
cluster, cluster_key, persist_filter, stale_read can also be set in
|
|
||||||
Vitastor configuration with `antietcd_` prefix.
|
|
||||||
|
|
||||||
You can dump/load data to or from antietcd using Antietcd `anticli` tool:
|
|
||||||
|
|
||||||
```
|
|
||||||
npm exec anticli -e http://etcd:2379/v3 get --prefix '' --no-temp > dump.json
|
|
||||||
npm exec anticli -e http://antietcd:2379/v3 load < dump.json
|
|
||||||
```
|
|
||||||
info_ru: |
|
|
||||||
Включить экспериментальный встроенный заменитель etcd (кластерную БД ключ-значение):
|
|
||||||
[antietcd](https://git.yourcmc.ru/vitalif/antietcd/).
|
|
||||||
|
|
||||||
Если параметр установлен в true, монитор запускает antietcd автоматически,
|
|
||||||
если обнаруживает сетевой интерфейс с одним из адресов, указанных в опции
|
|
||||||
конфигурации `etcd_address` (в `/etc/vitastor/vitastor.conf` или в опциях
|
|
||||||
командной строки монитора). Если таких адресов несколько, также проверяется
|
|
||||||
опция `antietcd_port` и antietcd запускается для адреса с соответствующим
|
|
||||||
портом. По умолчанию antietcd принимает подключения по выбранному совпадающему
|
|
||||||
IP, но его также можно определить вручную опцией `antietcd_ip`.
|
|
||||||
|
|
||||||
При запуске antietcd монитор сам хранит центральные метаданные кластера и
|
|
||||||
выставляет etcd-совместимое REST API. На диске эти метаданные хранятся в файле
|
|
||||||
`/var/lib/vitastor/mon_2379.json.gz` (можно переопределить параметрами
|
|
||||||
antietcd_data_file или antietcd_data_dir). Все остальные параметры antietcd
|
|
||||||
(смотрите [по ссылке](https://git.yourcmc.ru/vitalif/antietcd/)), за исключением
|
|
||||||
node_id, cluster, cluster_key, persist_filter, stale_read также можно задавать
|
|
||||||
в конфигурации Vitastor с префиксом `antietcd_`.
|
|
||||||
|
|
||||||
Вы можете выгружать/загружать данные в или из antietcd с помощью его инструмента
|
|
||||||
`anticli`:
|
|
||||||
|
|
||||||
```
|
|
||||||
npm exec anticli -e http://etcd:2379/v3 get --prefix '' --no-temp > dump.json
|
|
||||||
npm exec anticli -e http://antietcd:2379/v3 load < dump.json
|
|
||||||
```
|
|
||||||
- name: enable_prometheus
|
|
||||||
type: bool
|
|
||||||
default: true
|
|
||||||
info: |
|
|
||||||
Enable built-in Prometheus metrics exporter at mon_http_port (8060 by default).
|
|
||||||
|
|
||||||
Note that only the active (master) monitor exposes metrics, others return
|
|
||||||
HTTP 503. So you should add all monitor URLs to your Prometheus job configuration.
|
|
||||||
|
|
||||||
Grafana dashboard suitable for this exporter is here: [Vitastor-Grafana-6+.json](../../mon/scripts/Vitastor-Grafana-6+.json).
|
|
||||||
info_ru: |
|
|
||||||
Включить встроенный Prometheus-экспортер метрик на порту mon_http_port (по умолчанию 8060).
|
|
||||||
|
|
||||||
Обратите внимание, что метрики выставляет только активный (главный) монитор, остальные
|
|
||||||
возвращают статус HTTP 503, поэтому вам следует добавлять адреса всех мониторов
|
|
||||||
в задание по сбору метрик Prometheus.
|
|
||||||
|
|
||||||
Дашборд для Grafana, подходящий для этого экспортера: [Vitastor-Grafana-6+.json](../../mon/scripts/Vitastor-Grafana-6+.json).
|
|
||||||
- name: mon_http_port
|
|
||||||
type: int
|
|
||||||
default: 8060
|
|
||||||
info: HTTP port for monitors to listen on (including metrics exporter)
|
|
||||||
info_ru: Порт, на котором мониторы принимают HTTP-соединения (в том числе для отдачи метрик)
|
|
||||||
- name: mon_http_ip
|
|
||||||
type: string
|
|
||||||
info: IP address for monitors to listen on (all addresses by default)
|
|
||||||
info_ru: IP-адрес, на котором мониторы принимают HTTP-соединения (по умолчанию все адреса)
|
|
||||||
- name: mon_https_cert
|
|
||||||
type: string
|
|
||||||
info: Path to PEM SSL certificate file for monitor to listen using HTTPS
|
|
||||||
info_ru: Путь к PEM-файлу SSL-сертификата для монитора, чтобы принимать соединения через HTTPS
|
|
||||||
- name: mon_https_key
|
|
||||||
type: string
|
|
||||||
info: Path to PEM SSL private key file for monitor to listen using HTTPS
|
|
||||||
info_ru: Путь к PEM-файлу секретного SSL-ключа для монитора, чтобы принимать соединения через HTTPS
|
|
||||||
- name: mon_https_client_auth
|
|
||||||
type: bool
|
|
||||||
default: false
|
|
||||||
info: Enable HTTPS client certificate-based authorization for monitor connections
|
|
||||||
info_ru: Включить в HTTPS-сервере монитора авторизацию по клиентским сертификатам
|
|
||||||
- name: mon_https_ca
|
|
||||||
type: string
|
|
||||||
info: Path to CA certificate for client HTTPS authorization
|
|
||||||
info_ru: Путь к удостоверяющему сертификату для авторизации клиентских HTTPS соединений
|
|
||||||
- name: etcd_mon_ttl
|
- name: etcd_mon_ttl
|
||||||
type: sec
|
type: sec
|
||||||
min: 5
|
min: 5
|
||||||
|
@ -172,27 +72,3 @@
|
||||||
info_ru: |
|
info_ru: |
|
||||||
Использовать старый генератор комбинаций PG, не поддерживающий [level_placement](pool.ru.md#level_placement)
|
Использовать старый генератор комбинаций PG, не поддерживающий [level_placement](pool.ru.md#level_placement)
|
||||||
и [raw_placement](pool.ru.md#raw_placement) для пулов, которые не используют данные функции.
|
и [raw_placement](pool.ru.md#raw_placement) для пулов, которые не используют данные функции.
|
||||||
- name: osd_backfillfull_ratio
|
|
||||||
type: float
|
|
||||||
default: 0.99
|
|
||||||
info: |
|
|
||||||
Monitors try to prevent OSDs becoming 100% full during rebalance or recovery by
|
|
||||||
calculating how much space will be occupied on every OSD after all rebalance
|
|
||||||
and recovery operations finish, and pausing rebalance and recovery if that
|
|
||||||
amount of space exceeds OSD capacity multiplied by the value of this
|
|
||||||
configuration parameter.
|
|
||||||
|
|
||||||
Future used space is calculated by summing space used by all user data blocks
|
|
||||||
(objects) in all PGs placed on a specific OSD, even if some of these objects
|
|
||||||
currently reside on a different set of OSDs.
|
|
||||||
info_ru: |
|
|
||||||
Мониторы стараются предотвратить 100% заполнение OSD в процессе ребаланса
|
|
||||||
или восстановления, рассчитывая, сколько места будет занято на каждом OSD после
|
|
||||||
завершения всех операций ребаланса и восстановления, и приостанавливая
|
|
||||||
ребаланс и восстановление, если рассчитанный объём превышает ёмкость OSD,
|
|
||||||
умноженную на значение данного параметра.
|
|
||||||
|
|
||||||
Будущее занятое место рассчитывается сложением места, занятого всеми
|
|
||||||
пользовательскими блоками данных (объектами) во всех PG, расположенных
|
|
||||||
на конкретном OSD, даже если часть этих объектов в данный момент находится
|
|
||||||
на другом наборе OSD.
|
|
||||||
|
|
|
@ -48,17 +48,11 @@
|
||||||
type: string
|
type: string
|
||||||
info: |
|
info: |
|
||||||
RDMA device name to use for Vitastor OSD communications (for example,
|
RDMA device name to use for Vitastor OSD communications (for example,
|
||||||
"rocep5s0f0"). If not specified, Vitastor will try to find an RoCE
|
"rocep5s0f0"). Now Vitastor supports all adapters, even ones without
|
||||||
device matching [osd_network](osd.en.md#osd_network), preferring RoCEv2,
|
ODP support, like Mellanox ConnectX-3 and non-Mellanox cards.
|
||||||
or choose the first available RDMA device if no RoCE devices are
|
|
||||||
found or if `osd_network` is not specified. Auto-selection is also
|
|
||||||
unsupported with old libibverbs < v32, like in Debian 10 Buster or
|
|
||||||
CentOS 7.
|
|
||||||
|
|
||||||
Vitastor supports all adapters, even ones without ODP support, like
|
Versions up to Vitastor 1.2.0 required ODP which is only present in
|
||||||
Mellanox ConnectX-3 and non-Mellanox cards. Versions up to Vitastor
|
Mellanox ConnectX >= 4. See also [rdma_odp](#rdma_odp).
|
||||||
1.2.0 required ODP which is only present in Mellanox ConnectX >= 4.
|
|
||||||
See also [rdma_odp](#rdma_odp).
|
|
||||||
|
|
||||||
Run `ibv_devinfo -v` as root to list available RDMA devices and their
|
Run `ibv_devinfo -v` as root to list available RDMA devices and their
|
||||||
features.
|
features.
|
||||||
|
@ -70,17 +64,12 @@
|
||||||
PFC (Priority Flow Control) and ECN (Explicit Congestion Notification).
|
PFC (Priority Flow Control) and ECN (Explicit Congestion Notification).
|
||||||
info_ru: |
|
info_ru: |
|
||||||
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
|
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
|
||||||
Если не указано, Vitastor попробует найти RoCE-устройство, соответствующее
|
Сейчас Vitastor поддерживает все модели адаптеров, включая те, у которых
|
||||||
[osd_network](osd.en.md#osd_network), предпочитая RoCEv2, или выбрать первое
|
|
||||||
попавшееся RDMA-устройство, если RoCE-устройств нет или если сеть `osd_network`
|
|
||||||
не задана. Также автовыбор не поддерживается со старыми версиями библиотеки
|
|
||||||
libibverbs < v32, например в Debian 10 Buster или CentOS 7.
|
|
||||||
|
|
||||||
Vitastor поддерживает все модели адаптеров, включая те, у которых
|
|
||||||
нет поддержки ODP, то есть вы можете использовать RDMA с ConnectX-3 и
|
нет поддержки ODP, то есть вы можете использовать RDMA с ConnectX-3 и
|
||||||
картами производства не Mellanox. Версии Vitastor до 1.2.0 включительно
|
картами производства не Mellanox.
|
||||||
требовали ODP, который есть только на Mellanox ConnectX 4 и более новых.
|
|
||||||
См. также [rdma_odp](#rdma_odp).
|
Версии Vitastor до 1.2.0 включительно требовали ODP, который есть только
|
||||||
|
на Mellanox ConnectX 4 и более новых. См. также [rdma_odp](#rdma_odp).
|
||||||
|
|
||||||
Запустите `ibv_devinfo -v` от имени суперпользователя, чтобы посмотреть
|
Запустите `ibv_devinfo -v` от имени суперпользователя, чтобы посмотреть
|
||||||
список доступных RDMA-устройств, их параметры и возможности.
|
список доступных RDMA-устройств, их параметры и возможности.
|
||||||
|
@ -105,29 +94,23 @@
|
||||||
`ibv_devinfo -v`.
|
`ibv_devinfo -v`.
|
||||||
- name: rdma_gid_index
|
- name: rdma_gid_index
|
||||||
type: int
|
type: int
|
||||||
|
default: 0
|
||||||
info: |
|
info: |
|
||||||
Global address identifier index of the RDMA device to use. Different GID
|
Global address identifier index of the RDMA device to use. Different GID
|
||||||
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
|
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
|
||||||
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
|
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
|
||||||
you need.
|
you need.
|
||||||
|
|
||||||
If not specified, Vitastor will try to auto-select a RoCEv2 IPv4 GID, then
|
**IMPORTANT:** If you want to use RoCEv2 (as recommended) then the correct
|
||||||
RoCEv2 IPv6 GID, then RoCEv1 IPv4 GID, then RoCEv1 IPv6 GID, then IB GID.
|
rdma_gid_index is usually 1 (IPv6) or 3 (IPv4).
|
||||||
GID auto-selection is unsupported with libibverbs < v32.
|
|
||||||
|
|
||||||
A correct rdma_gid_index for RoCEv2 is usually 1 (IPv6) or 3 (IPv4).
|
|
||||||
info_ru: |
|
info_ru: |
|
||||||
Номер глобального идентификатора адреса RDMA-устройства, который следует
|
Номер глобального идентификатора адреса RDMA-устройства, который следует
|
||||||
использовать. Разным gid_index могут соответствовать разные протоколы связи:
|
использовать. Разным gid_index могут соответствовать разные протоколы связи:
|
||||||
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
|
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
|
||||||
словом "GID" в выводе команды `ibv_devinfo -v`.
|
словом "GID" в выводе команды `ibv_devinfo -v`.
|
||||||
|
|
||||||
Если не указан, Vitastor попробует автоматически выбрать сначала GID,
|
**ВАЖНО:** Если вы хотите использовать RoCEv2 (как мы и рекомендуем), то
|
||||||
соответствующий RoCEv2 IPv4, потом RoCEv2 IPv6, потом RoCEv1 IPv4, потом
|
правильный rdma_gid_index, как правило, 1 (IPv6) или 3 (IPv4).
|
||||||
RoCEv1 IPv6, потом IB. Авто-выбор GID не поддерживается со старыми версиями
|
|
||||||
libibverbs < v32.
|
|
||||||
|
|
||||||
Правильный rdma_gid_index для RoCEv2, как правило, 1 (IPv6) или 3 (IPv4).
|
|
||||||
- name: rdma_mtu
|
- name: rdma_mtu
|
||||||
type: int
|
type: int
|
||||||
default: 4096
|
default: 4096
|
||||||
|
@ -299,7 +282,7 @@
|
||||||
etcd_report_interval, чтобы keepalive гарантированно работал.
|
etcd_report_interval, чтобы keepalive гарантированно работал.
|
||||||
- name: etcd_ws_keepalive_interval
|
- name: etcd_ws_keepalive_interval
|
||||||
type: sec
|
type: sec
|
||||||
default: 5
|
default: 30
|
||||||
online: true
|
online: true
|
||||||
info: |
|
info: |
|
||||||
etcd websocket ping interval required to keep the connection alive and
|
etcd websocket ping interval required to keep the connection alive and
|
||||||
|
|
|
@ -1,21 +1,3 @@
|
||||||
- name: osd_iothread_count
|
|
||||||
type: int
|
|
||||||
default: 0
|
|
||||||
info: |
|
|
||||||
TCP network I/O thread count for OSD. When non-zero, a single OSD process
|
|
||||||
may handle more TCP I/O, but at a cost of increased latency because thread
|
|
||||||
switching overhead occurs. RDMA isn't affected by this option.
|
|
||||||
|
|
||||||
Because of latency, instead of enabling OSD I/O threads it's recommended to
|
|
||||||
just create multiple OSDs per disk, or use RDMA.
|
|
||||||
info_ru: |
|
|
||||||
Число отдельных потоков для обработки ввода-вывода через TCP-сеть на
|
|
||||||
стороне OSD. Включение опции позволяет каждому отдельному OSD передавать
|
|
||||||
по сети больше данных, но ухудшает задержку из-за накладных расходов
|
|
||||||
переключения потоков. На работу RDMA опция не влияет.
|
|
||||||
|
|
||||||
Из-за задержек вместо включения потоков ввода-вывода OSD рекомендуется
|
|
||||||
просто создавать по несколько OSD на каждом диске, или использовать RDMA.
|
|
||||||
- name: etcd_report_interval
|
- name: etcd_report_interval
|
||||||
type: sec
|
type: sec
|
||||||
default: 5
|
default: 5
|
||||||
|
|
|
@ -6,18 +6,9 @@
|
||||||
|
|
||||||
# Kubernetes CSI
|
# Kubernetes CSI
|
||||||
|
|
||||||
Vitastor has a CSI plugin for Kubernetes which supports block-based and VitastorFS-based volumes.
|
Vitastor has a CSI plugin for Kubernetes which supports RWO (and block RWX) volumes.
|
||||||
|
|
||||||
Block-based volumes may be formatted and mounted with a normal FS (ext4 or xfs). Such volumes
|
To deploy it, take manifests from [csi/deploy/](../../csi/deploy/) directory, put your
|
||||||
only support RWO (ReadWriteOnce) mode.
|
|
||||||
|
|
||||||
Block-based volumes may also be left without FS and attached into the container as a block
|
|
||||||
device. Such volumes also support RWX (ReadWriteMany) mode.
|
|
||||||
|
|
||||||
VitastorFS-based volumes use a clustered file system and support FS-based RWX (ReadWriteMany)
|
|
||||||
mode. However, such volumes don't support quotas and snapshots.
|
|
||||||
|
|
||||||
To deploy the CSI plugin, take manifests from [csi/deploy/](../../csi/deploy/) directory, put your
|
|
||||||
Vitastor configuration in [001-csi-config-map.yaml](../../csi/deploy/001-csi-config-map.yaml),
|
Vitastor configuration in [001-csi-config-map.yaml](../../csi/deploy/001-csi-config-map.yaml),
|
||||||
configure storage class in [009-storage-class.yaml](../../csi/deploy/009-storage-class.yaml)
|
configure storage class in [009-storage-class.yaml](../../csi/deploy/009-storage-class.yaml)
|
||||||
and apply all `NNN-*.yaml` manifests to your Kubernetes installation:
|
and apply all `NNN-*.yaml` manifests to your Kubernetes installation:
|
||||||
|
@ -32,16 +23,16 @@ After that you'll be able to create PersistentVolumes.
|
||||||
kernel modules enabled (vdpa, vduse, virtio-vdpa). If your distribution doesn't
|
kernel modules enabled (vdpa, vduse, virtio-vdpa). If your distribution doesn't
|
||||||
have them pre-built - build them yourself ([instructions](../usage/qemu.en.md#vduse)),
|
have them pre-built - build them yourself ([instructions](../usage/qemu.en.md#vduse)),
|
||||||
I promise it's worth it :-). When VDUSE is unavailable, CSI driver uses [NBD](../usage/nbd.en.md)
|
I promise it's worth it :-). When VDUSE is unavailable, CSI driver uses [NBD](../usage/nbd.en.md)
|
||||||
to map Vitastor devices. NBD is slower and, with kernels older than 5.19, unmountable
|
to map Vitastor devices. NBD is slower and prone to timeout issues: if Vitastor
|
||||||
if the cluster becomes unresponsible.
|
cluster becomes unresponsible for more than [nbd_timeout](../config/client.en.md#nbd_timeout),
|
||||||
|
the NBD device detaches and breaks pods using it.
|
||||||
|
|
||||||
## Features
|
## Features
|
||||||
|
|
||||||
Vitastor CSI supports:
|
Vitastor CSI supports:
|
||||||
- Kubernetes starting with 1.20 (or 1.17 for older vitastor-csi <= 1.1.0)
|
- Kubernetes starting with 1.20 (or 1.17 for older vitastor-csi <= 1.1.0)
|
||||||
- Block-based FS-formatted RWO (ReadWriteOnce) volumes. Example: [PVC](../../csi/deploy/example-pvc.yaml), [pod](../../csi/deploy/example-test-pod.yaml)
|
- Filesystem RWO (ReadWriteOnce) volumes. Example: [PVC](../../csi/deploy/example-pvc.yaml), [pod](../../csi/deploy/example-test-pod.yaml)
|
||||||
- Raw block RWX (ReadWriteMany) volumes. Example: [PVC](../../csi/deploy/example-pvc-block.yaml), [pod](../../csi/deploy/example-test-pod-block.yaml)
|
- Raw block RWX (ReadWriteMany) volumes. Example: [PVC](../../csi/deploy/example-pvc-block.yaml), [pod](../../csi/deploy/example-test-pod-block.yaml)
|
||||||
- VitastorFS-based volumes RWX (ReadWriteMany) volumes. Example: [storage class](../../csi/deploy/example-storage-class-fs.yaml)
|
|
||||||
- Volume expansion
|
- Volume expansion
|
||||||
- Volume snapshots. Example: [snapshot class](../../csi/deploy/example-snapshot-class.yaml), [snapshot](../../csi/deploy/example-snapshot.yaml), [clone](../../csi/deploy/example-snapshot-clone.yaml)
|
- Volume snapshots. Example: [snapshot class](../../csi/deploy/example-snapshot-class.yaml), [snapshot](../../csi/deploy/example-snapshot.yaml), [clone](../../csi/deploy/example-snapshot-clone.yaml)
|
||||||
- [VDUSE](../usage/qemu.en.md#vduse) (preferred) and [NBD](../usage/nbd.en.md) device mapping methods
|
- [VDUSE](../usage/qemu.en.md#vduse) (preferred) and [NBD](../usage/nbd.en.md) device mapping methods
|
||||||
|
|
|
@ -6,17 +6,7 @@
|
||||||
|
|
||||||
# Kubernetes CSI
|
# Kubernetes CSI
|
||||||
|
|
||||||
У Vitastor есть CSI-плагин для Kubernetes, поддерживающий блочные тома и тома на основе
|
У Vitastor есть CSI-плагин для Kubernetes, поддерживающий RWO, а также блочные RWX, тома.
|
||||||
кластерной ФС VitastorFS.
|
|
||||||
|
|
||||||
Блочные тома могут быть отформатированы и примонтированы со стандартной ФС (ext4 или xfs).
|
|
||||||
Такие тома поддерживают только режим RWO (ReadWriteOnce, одновременный доступ с одного узла).
|
|
||||||
|
|
||||||
Блочные тома также могут не форматироваться и подключаться в контейнер в виде блочного устройства.
|
|
||||||
В таком случае их можно подключать в режиме RWX (ReadWriteMany, одновременный доступ с многих узлов).
|
|
||||||
|
|
||||||
Тома на основе VitastorFS используют кластерную ФС и поэтому также поддерживают режим RWX
|
|
||||||
(ReadWriteMany). Однако, такие тома не поддерживают ограничение размера и снимки.
|
|
||||||
|
|
||||||
Для установки возьмите манифесты из директории [csi/deploy/](../../csi/deploy/), поместите
|
Для установки возьмите манифесты из директории [csi/deploy/](../../csi/deploy/), поместите
|
||||||
вашу конфигурацию подключения к Vitastor в [csi/deploy/001-csi-config-map.yaml](../../csi/deploy/001-csi-config-map.yaml),
|
вашу конфигурацию подключения к Vitastor в [csi/deploy/001-csi-config-map.yaml](../../csi/deploy/001-csi-config-map.yaml),
|
||||||
|
@ -43,7 +33,6 @@ CSI-плагин Vitastor поддерживает:
|
||||||
- Версии Kubernetes, начиная с 1.20 (или с 1.17 для более старых vitastor-csi <= 1.1.0)
|
- Версии Kubernetes, начиная с 1.20 (или с 1.17 для более старых vitastor-csi <= 1.1.0)
|
||||||
- Файловые RWO (ReadWriteOnce) тома. Пример: [PVC](../../csi/deploy/example-pvc.yaml), [под](../../csi/deploy/example-test-pod.yaml)
|
- Файловые RWO (ReadWriteOnce) тома. Пример: [PVC](../../csi/deploy/example-pvc.yaml), [под](../../csi/deploy/example-test-pod.yaml)
|
||||||
- Сырые блочные RWX (ReadWriteMany) тома. Пример: [PVC](../../csi/deploy/example-pvc-block.yaml), [под](../../csi/deploy/example-test-pod-block.yaml)
|
- Сырые блочные RWX (ReadWriteMany) тома. Пример: [PVC](../../csi/deploy/example-pvc-block.yaml), [под](../../csi/deploy/example-test-pod-block.yaml)
|
||||||
- Основанные на VitastorFS RWX (ReadWriteMany) тома. Пример: [класс хранения](../../csi/deploy/example-storage-class-fs.yaml)
|
|
||||||
- Расширение размера томов
|
- Расширение размера томов
|
||||||
- Снимки томов. Пример: [класс снимков](../../csi/deploy/example-snapshot-class.yaml), [снимок](../../csi/deploy/example-snapshot.yaml), [клон снимка](../../csi/deploy/example-snapshot-clone.yaml)
|
- Снимки томов. Пример: [класс снимков](../../csi/deploy/example-snapshot-class.yaml), [снимок](../../csi/deploy/example-snapshot.yaml), [клон снимка](../../csi/deploy/example-snapshot-clone.yaml)
|
||||||
- Способы подключения устройств [VDUSE](../usage/qemu.ru.md#vduse) (предпочитаемый) и [NBD](../usage/nbd.ru.md)
|
- Способы подключения устройств [VDUSE](../usage/qemu.ru.md#vduse) (предпочитаемый) и [NBD](../usage/nbd.ru.md)
|
||||||
|
|
|
@ -1,186 +0,0 @@
|
||||||
[Documentation](../../README.md#documentation) → Installation → OpenNebula
|
|
||||||
|
|
||||||
-----
|
|
||||||
|
|
||||||
[Читать на русском](opennebula.ru.md)
|
|
||||||
|
|
||||||
# OpenNebula
|
|
||||||
|
|
||||||
## Automatic Installation
|
|
||||||
|
|
||||||
OpenNebula plugin is packaged as `vitastor-opennebula` Debian and RPM package since Vitastor 1.9.0. So:
|
|
||||||
|
|
||||||
- Run `apt-get install vitastor-opennebula` or `yum install vitastor-opennebula` after installing OpenNebula on all nodes
|
|
||||||
- Check that it prints "OK, Vitastor OpenNebula patches successfully applied" or "OK, Vitastor OpenNebula patches are already applied"
|
|
||||||
- If it does not, refer to [Manual Installation](#manual-installation) and apply configuration file changes manually
|
|
||||||
- Make sure that Vitastor patched versions of QEMU and libvirt are installed
|
|
||||||
(`dpkg -l qemu-system-x86`, `dpkg -l | grep libvirt`, `rpm -qa | grep qemu`, `rpm -qa | grep qemu`, `rpm -qa | grep libvirt-libs` should show "vitastor" in version names)
|
|
||||||
- [Block VM access to Vitastor cluster](#block-vm-access-to-vitastor-cluster)
|
|
||||||
|
|
||||||
## Manual Installation
|
|
||||||
|
|
||||||
Install OpenNebula. Then, on each node:
|
|
||||||
|
|
||||||
- Copy [opennebula/remotes](../../opennebula/remotes) into `/var/lib/one` recursively: `cp -r opennebula/remotes /var/lib/one/`
|
|
||||||
- Copy [opennebula/sudoers.d](../../opennebula/sudoers.d) to `/etc`: `cp -r opennebula/sudoers.d /etc/`
|
|
||||||
- Apply [downloader-vitastor.sh.diff](../../opennebula/remotes/datastore/vitastor/downloader-vitastor.sh.diff) to `/var/lib/one/remotes/datastore/downloader.sh`:
|
|
||||||
`patch /var/lib/one/remotes/datastore/downloader.sh < opennebula/remotes/datastore/vitastor/downloader-vitastor.sh.diff` - or read the patch and apply the same change manually
|
|
||||||
- Add `kvm-vitastor` to `LIVE_DISK_SNAPSHOTS` in `/etc/one/vmm_exec/vmm_execrc`
|
|
||||||
- If on Debian or Ubuntu (and AppArmor is used), add Vitastor config file path(s) to `/etc/apparmor.d/local/abstractions/libvirt-qemu`: for example,
|
|
||||||
`echo ' "/etc/vitastor/vitastor.conf" r,' >> /etc/apparmor.d/local/abstractions/libvirt-qemu`
|
|
||||||
- Apply changes to `/etc/one/oned.conf`
|
|
||||||
|
|
||||||
### oned.conf changes
|
|
||||||
|
|
||||||
1. Add deploy script override in kvm VM_MAD: add `-l deploy.vitastor` to ARGUMENTS.
|
|
||||||
|
|
||||||
```diff
|
|
||||||
VM_MAD = [
|
|
||||||
NAME = "kvm",
|
|
||||||
SUNSTONE_NAME = "KVM",
|
|
||||||
EXECUTABLE = "one_vmm_exec",
|
|
||||||
- ARGUMENTS = "-t 15 -r 0 kvm -p",
|
|
||||||
+ ARGUMENTS = "-t 15 -r 0 kvm -p -l deploy=deploy.vitastor",
|
|
||||||
DEFAULT = "vmm_exec/vmm_exec_kvm.conf",
|
|
||||||
TYPE = "kvm",
|
|
||||||
KEEP_SNAPSHOTS = "yes",
|
|
||||||
LIVE_RESIZE = "yes",
|
|
||||||
SUPPORT_SHAREABLE = "yes",
|
|
||||||
IMPORTED_VMS_ACTIONS = "terminate, terminate-hard, hold, release, suspend,
|
|
||||||
resume, delete, reboot, reboot-hard, resched, unresched, disk-attach,
|
|
||||||
disk-detach, nic-attach, nic-detach, snapshot-create, snapshot-delete,
|
|
||||||
resize, updateconf, update"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
Optional: if you also want to save VM RAM checkpoints to Vitastor, use
|
|
||||||
`-l deploy=deploy.vitastor,save=save.vitastor,restore=restore.vitastor`
|
|
||||||
instead of just `-l deploy=deploy.vitastor`.
|
|
||||||
|
|
||||||
2. Add `vitastor` to TM_MAD.ARGUMENTS and DATASTORE_MAD.ARGUMENTS:
|
|
||||||
|
|
||||||
```diff
|
|
||||||
TM_MAD = [
|
|
||||||
EXECUTABLE = "one_tm",
|
|
||||||
- ARGUMENTS = "-t 15 -d dummy,lvm,shared,fs_lvm,fs_lvm_ssh,qcow2,ssh,ceph,dev,vcenter,iscsi_libvirt"
|
|
||||||
+ ARGUMENTS = "-t 15 -d dummy,lvm,shared,fs_lvm,fs_lvm_ssh,qcow2,ssh,ceph,vitastor,dev,vcenter,iscsi_libvirt"
|
|
||||||
]
|
|
||||||
|
|
||||||
DATASTORE_MAD = [
|
|
||||||
EXECUTABLE = "one_datastore",
|
|
||||||
- ARGUMENTS = "-t 15 -d dummy,fs,lvm,ceph,dev,iscsi_libvirt,vcenter,restic,rsync -s shared,ssh,ceph,fs_lvm,fs_lvm_ssh,qcow2,vcenter"
|
|
||||||
+ ARGUMENTS = "-t 15 -d dummy,fs,lvm,ceph,vitastor,dev,iscsi_libvirt,vcenter,restic,rsync -s shared,ssh,ceph,vitastor,fs_lvm,fs_lvm_ssh,qcow2,vcenter"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
3. Add INHERIT_DATASTORE_ATTR for two Vitastor attributes:
|
|
||||||
|
|
||||||
```
|
|
||||||
INHERIT_DATASTORE_ATTR = "VITASTOR_CONF"
|
|
||||||
INHERIT_DATASTORE_ATTR = "IMAGE_PREFIX"
|
|
||||||
```
|
|
||||||
|
|
||||||
4. Add TM_MAD_CONF and DS_MAD_CONF for Vitastor:
|
|
||||||
|
|
||||||
```
|
|
||||||
TM_MAD_CONF = [
|
|
||||||
NAME = "vitastor", LN_TARGET = "NONE", CLONE_TARGET = "SELF", SHARED = "YES",
|
|
||||||
DS_MIGRATE = "NO", DRIVER = "raw", ALLOW_ORPHANS="format",
|
|
||||||
TM_MAD_SYSTEM = "ssh,shared", LN_TARGET_SSH = "SYSTEM", CLONE_TARGET_SSH = "SYSTEM",
|
|
||||||
DISK_TYPE_SSH = "FILE", LN_TARGET_SHARED = "NONE",
|
|
||||||
CLONE_TARGET_SHARED = "SELF", DISK_TYPE_SHARED = "FILE"
|
|
||||||
]
|
|
||||||
|
|
||||||
DS_MAD_CONF = [
|
|
||||||
NAME = "vitastor",
|
|
||||||
REQUIRED_ATTRS = "DISK_TYPE,BRIDGE_LIST",
|
|
||||||
PERSISTENT_ONLY = "NO",
|
|
||||||
MARKETPLACE_ACTIONS = "export"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
## Create Datastores
|
|
||||||
|
|
||||||
Example Image and System Datastore definitions:
|
|
||||||
[opennebula/vitastor-imageds.conf](../../opennebula/vitastor-imageds.conf) and
|
|
||||||
[opennebula/vitastor-systemds.conf](../../opennebula/vitastor-systemds.conf).
|
|
||||||
|
|
||||||
Change parameters to your will:
|
|
||||||
|
|
||||||
- POOL_NAME is Vitastor pool name to store images.
|
|
||||||
- IMAGE_PREFIX is a string prepended to all Vitastor image names.
|
|
||||||
- BRIDGE_LIST is a list of hosts with access to Vitastor cluster, mostly used for image (not system) datastore operations.
|
|
||||||
- VITASTOR_CONF is the path to cluster configuration. Note that it should be also added to `/etc/apparmor.d/local/abstractions/libvirt-qemu` if you use AppArmor.
|
|
||||||
- STAGING_DIR is a temporary directory used when importing external images. Should have free space sufficient for downloading external images.
|
|
||||||
|
|
||||||
Then create datastores using `onedatastore create vitastor-imageds.conf` and `onedatastore create vitastor-systemds.conf` (or use UI).
|
|
||||||
|
|
||||||
## Block VM access to Vitastor cluster
|
|
||||||
|
|
||||||
Vitastor doesn't support any authentication yet, so you MUST block VM guest access to the Vitastor cluster at the network level.
|
|
||||||
|
|
||||||
If you use VLAN networking for VMs - make sure you use different VLANs for VMs and hypervisor/storage network and
|
|
||||||
block access between them using your firewall/switch configuration.
|
|
||||||
|
|
||||||
If you use something more stupid like bridged networking, you probably have to use manual firewall/iptables setup
|
|
||||||
to only allow access to Vitastor from hypervisor IPs.
|
|
||||||
|
|
||||||
Also you need to switch network to "Bridged & Security Groups" and enable IP spoofing filters in OpenNebula.
|
|
||||||
Problem is that OpenNebula's IP spoofing filter doesn't affect local interfaces of the hypervisor i.e. when
|
|
||||||
it's enabled a VM can't talk to other VMs or to the outer world using a spoofed IP, but it CAN talk to the
|
|
||||||
hypervisor if it takes an IP from its subnet. To fix that you also need some more iptables.
|
|
||||||
|
|
||||||
So the complete "stupid" bridged network filter setup could look like the following
|
|
||||||
(here `10.0.3.0/24` is the VM subnet and `10.0.2.0/24` is the hypervisor subnet):
|
|
||||||
|
|
||||||
```
|
|
||||||
# Allow incoming traffic from physical device
|
|
||||||
iptables -A INPUT -m physdev --physdev-in eth0 -j ACCEPT
|
|
||||||
# Do not allow incoming traffic from VMs, but not from VM subnet
|
|
||||||
iptables -A INPUT ! -s 10.0.3.0/24 -i onebr0 -j DROP
|
|
||||||
# Drop traffic from VMs to hypervisor/storage subnet
|
|
||||||
iptables -I FORWARD 1 -s 10.0.3.0/24 -d 10.0.2.0/24 -j DROP
|
|
||||||
```
|
|
||||||
|
|
||||||
## Testing
|
|
||||||
|
|
||||||
The OpenNebula plugin includes quite a bit of bash scripts, so here's their description to get an idea about what they actually do.
|
|
||||||
|
|
||||||
| Script | Action | How to Test |
|
|
||||||
| ----------------------- | ----------------------------------------- | ------------------------------------------------------------------------------------ |
|
|
||||||
| vmm/kvm/deploy.vitastor | Start a VM | Create and start a VM with Vitastor disk(s): persistent / non-persistent / volatile. |
|
|
||||||
| vmm/kvm/save.vitastor | Save VM memory checkpoint | Stop a VM using "Stop" command. |
|
|
||||||
| vmm/kvm/restore.vitastor| Restore VM memory checkpoint | Start a VM back after stopping it. |
|
|
||||||
| datastore/clone | Copy an image as persistent | Create a VM template and instantiate it as persistent. |
|
|
||||||
| datastore/cp | Import an external image | Import a VM template with images from Marketplace. |
|
|
||||||
| datastore/export | Export an image as URL | Probably: export a VM template with images to Marketplace. |
|
|
||||||
| datastore/mkfs | Create an image with FS | Storage → Images → Create → Type: Datablock, Location: Empty disk image, Filesystem: Not empty. |
|
|
||||||
| datastore/monitor | Monitor used space in image datastore | Check reported used/free space in image datastore list. |
|
|
||||||
| datastore/rm | Remove a persistent image | Storage → Images → Select an image → Delete. |
|
|
||||||
| datastore/snap_delete | Delete a snapshot of a persistent image | Storage → Images → Select an image → Select a snapshot → Delete; <br> To create an image with snapshot: attach a persistent image to a VM; create a snapshot; detach the image. |
|
|
||||||
| datastore/snap_flatten | Revert an image to snapshot and delete other snapshots | Storage → Images → Select an image → Select a snapshot → Flatten. |
|
|
||||||
| datastore/snap_revert | Revert an image to snapshot | Storage → Images → Select an image → Select a snapshot → Revert. |
|
|
||||||
| datastore/stat | Get virtual size of an image in MB | No idea. Seems to be unused both in Vitastor and Ceph datastores. |
|
|
||||||
| tm/clone | Clone a non-persistent image to a VM disk | Attach a non-persistent image to a VM. |
|
|
||||||
| tm/context | Generate a contextualisation VM disk | Create a VM with enabled contextualisation (default). Common host FS-based version is used in Vitastor and Ceph datastores. |
|
|
||||||
| tm/cpds | Copy a VM disk / its snapshot to an image | Select a VM → Select a disk → Optionally select a snapshot → Save as. |
|
|
||||||
| tm/delete | Delete a cloned or volatile VM disk | Detach a volatile disk or a non-persistent image from a VM. |
|
|
||||||
| tm/failmigrate | Handle live migration failure | No action. Script is empty in Vitastor and Ceph. In other datastores, should roll back actions done by tm/premigrate. |
|
|
||||||
| tm/ln | Attach a persistent image to a VM | No action. Script is empty in Vitastor and Ceph. |
|
|
||||||
| tm/mkimage | Create a volatile disk, maybe with FS | Attach a volatile disk to a VM, with or without file system. |
|
|
||||||
| tm/mkswap | Create a volatile swap disk | Attach a volatile disk to a VM, formatted as swap. |
|
|
||||||
| tm/monitor | Monitor used space in system datastore | Check reported used/free space in system datastore list. |
|
|
||||||
| tm/mv | Move a migrated VM disk between hosts | Migrate a VM between hosts. In Vitastor and Ceph datastores, doesn't do any storage action. |
|
|
||||||
| tm/mvds | Detach a persistent image from a VM | No action. The opposite of tm/ln. Script is empty in Vitastor and Ceph. In other datastores, script may copy the image from VM host back to the datastore. |
|
|
||||||
| tm/postbackup | Executed after backup | Seems that the script just removes temporary files after backup. Perform a VM backup and check that temporary files are cleaned up. |
|
|
||||||
| tm/postbackup_live | Executed after backup of a running VM | Same as tm/postbackup, but for a running VM. |
|
|
||||||
| tm/postmigrate | Executed after VM live migration | No action. Only executed for system datastore, so the script tries to call other TMs for other disks. Except that, the script does nothing in Vitastor and Ceph datastores. |
|
|
||||||
| tm/prebackup | Actual backup script: backup VM disks | Set up "rsync" backup datastore → Backup a VM to it. |
|
|
||||||
| tm/prebackup_live | Backup VM disks of a running VM | Same as tm/prebackup, but also does fsfreeze/thaw. So perform a live backup, restore it and check that disks are consistent. |
|
|
||||||
| tm/premigrate | Executed before live migration | No action. Only executed for system datastore, so the script tries to call other TMs for other disks. Except that, the script does nothing in Vitastor and Ceph datastores. |
|
|
||||||
| tm/resize | Resize a VM disk | Select a VM → Select a non-persistent disk → Resize. |
|
|
||||||
| tm/restore | Restore VM disks from backup | Set up "rsync" backup datastore → Backup a VM to it → Restore it back. |
|
|
||||||
| tm/snap_create | Create a VM disk snapshot | Select a VM → Select a disk → Create snapshot. |
|
|
||||||
| tm/snap_create_live | Create a VM disk snapshot for a live VM | Select a running VM → Select a disk → Create snapshot. |
|
|
||||||
| tm/snap_delete | Delete a VM disk snapshot | Select a VM → Select a disk → Select a snapshot → Delete. |
|
|
||||||
| tm/snap_revert | Revert a VM disk to a snapshot | Select a VM → Select a disk → Select a snapshot → Revert. |
|
|
|
@ -1,189 +0,0 @@
|
||||||
[Документация](../../README-ru.md#документация) → Установка → OpenNebula
|
|
||||||
|
|
||||||
-----
|
|
||||||
|
|
||||||
[Read in English](opennebula.en.md)
|
|
||||||
|
|
||||||
# OpenNebula
|
|
||||||
|
|
||||||
## Автоматическая установка
|
|
||||||
|
|
||||||
Плагин OpenNebula Vitastor распространяется как Debian и RPM пакет `vitastor-opennebula`, начиная с версии Vitastor 1.9.0. Так что:
|
|
||||||
|
|
||||||
- Запустите `apt-get install vitastor-opennebula` или `yum install vitastor-opennebula` после установки OpenNebula на всех серверах
|
|
||||||
- Проверьте, что он выводит "OK, Vitastor OpenNebula patches successfully applied" или "OK, Vitastor OpenNebula patches are already applied" в процессе установки
|
|
||||||
- Если сообщение не выведено, пройдите по шагам инструкцию [Ручная установка](#ручная-установка) и примените правки файлов конфигурации вручную
|
|
||||||
- Удостоверьтесь, что установлены версии QEMU и libvirt с изменениями Vitastor
|
|
||||||
(`dpkg -l qemu-system-x86`, `dpkg -l | grep libvirt`, `rpm -qa | grep qemu`, `rpm -qa | grep qemu`, `rpm -qa | grep libvirt-libs` должны показывать "vitastor" в номере версии)
|
|
||||||
- [Заблокируйте доступ виртуальных машин в Vitastor](#блокировка-доступа-вм-в-vitastor)
|
|
||||||
|
|
||||||
## Ручная установка
|
|
||||||
|
|
||||||
Сначала установите саму OpenNebula. После этого, на каждом сервере:
|
|
||||||
|
|
||||||
- Скопируйте директорию [opennebula/remotes](../../opennebula/remotes) в `/var/lib/one`: `cp -r opennebula/remotes /var/lib/one/`
|
|
||||||
- Скопируйте директорию [opennebula/sudoers.d](../../opennebula/sudoers.d) в `/etc`: `cp -r opennebula/sudoers.d /etc/`
|
|
||||||
- Примените патч [downloader-vitastor.sh.diff](../../opennebula/remotes/datastore/vitastor/downloader-vitastor.sh.diff) к `/var/lib/one/remotes/datastore/downloader.sh`:
|
|
||||||
`patch /var/lib/one/remotes/datastore/downloader.sh < opennebula/remotes/datastore/vitastor/downloader-vitastor.sh.diff` - либо прочитайте патч и примените изменение вручную
|
|
||||||
- Добавьте `kvm-vitastor` в список `LIVE_DISK_SNAPSHOTS` в файле `/etc/one/vmm_exec/vmm_execrc`
|
|
||||||
- Если вы используете Debian или Ubuntu (и AppArmor), добавьте пути к файлу(ам) конфигурации Vitastor в файл `/etc/apparmor.d/local/abstractions/libvirt-qemu`: например,
|
|
||||||
`echo ' "/etc/vitastor/vitastor.conf" r,' >> /etc/apparmor.d/local/abstractions/libvirt-qemu`
|
|
||||||
- Примените изменения `/etc/one/oned.conf`
|
|
||||||
|
|
||||||
### Изменения oned.conf
|
|
||||||
|
|
||||||
1. Добавьте переопределение скрипта deploy в VM_MAD kvm, добавив `-l deploy.vitastor` в `ARGUMENTS`:
|
|
||||||
|
|
||||||
```diff
|
|
||||||
VM_MAD = [
|
|
||||||
NAME = "kvm",
|
|
||||||
SUNSTONE_NAME = "KVM",
|
|
||||||
EXECUTABLE = "one_vmm_exec",
|
|
||||||
- ARGUMENTS = "-t 15 -r 0 kvm -p",
|
|
||||||
+ ARGUMENTS = "-t 15 -r 0 kvm -p -l deploy=deploy.vitastor",
|
|
||||||
DEFAULT = "vmm_exec/vmm_exec_kvm.conf",
|
|
||||||
TYPE = "kvm",
|
|
||||||
KEEP_SNAPSHOTS = "yes",
|
|
||||||
LIVE_RESIZE = "yes",
|
|
||||||
SUPPORT_SHAREABLE = "yes",
|
|
||||||
IMPORTED_VMS_ACTIONS = "terminate, terminate-hard, hold, release, suspend,
|
|
||||||
resume, delete, reboot, reboot-hard, resched, unresched, disk-attach,
|
|
||||||
disk-detach, nic-attach, nic-detach, snapshot-create, snapshot-delete,
|
|
||||||
resize, updateconf, update"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
Опционально: если вы хотите также сохранять снимки памяти ВМ в Vitastor, добавьте
|
|
||||||
`-l deploy=deploy.vitastor,save=save.vitastor,restore=restore.vitastor`
|
|
||||||
вместо просто `-l deploy=deploy.vitastor`.
|
|
||||||
|
|
||||||
2. Добавьте `vitastor` в значения TM_MAD.ARGUMENTS и DATASTORE_MAD.ARGUMENTS:
|
|
||||||
|
|
||||||
```diff
|
|
||||||
TM_MAD = [
|
|
||||||
EXECUTABLE = "one_tm",
|
|
||||||
- ARGUMENTS = "-t 15 -d dummy,lvm,shared,fs_lvm,fs_lvm_ssh,qcow2,ssh,ceph,dev,vcenter,iscsi_libvirt"
|
|
||||||
+ ARGUMENTS = "-t 15 -d dummy,lvm,shared,fs_lvm,fs_lvm_ssh,qcow2,ssh,ceph,vitastor,dev,vcenter,iscsi_libvirt"
|
|
||||||
]
|
|
||||||
|
|
||||||
DATASTORE_MAD = [
|
|
||||||
EXECUTABLE = "one_datastore",
|
|
||||||
- ARGUMENTS = "-t 15 -d dummy,fs,lvm,ceph,dev,iscsi_libvirt,vcenter,restic,rsync -s shared,ssh,ceph,fs_lvm,fs_lvm_ssh,qcow2,vcenter"
|
|
||||||
+ ARGUMENTS = "-t 15 -d dummy,fs,lvm,ceph,vitastor,dev,iscsi_libvirt,vcenter,restic,rsync -s shared,ssh,ceph,vitastor,fs_lvm,fs_lvm_ssh,qcow2,vcenter"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
3. Добавьте строчки с INHERIT_DATASTORE_ATTR для двух атрибутов Vitastor-хранилищ:
|
|
||||||
|
|
||||||
```
|
|
||||||
INHERIT_DATASTORE_ATTR = "VITASTOR_CONF"
|
|
||||||
INHERIT_DATASTORE_ATTR = "IMAGE_PREFIX"
|
|
||||||
```
|
|
||||||
|
|
||||||
4. Добавьте TM_MAD_CONF и DS_MAD_CONF для Vitastor:
|
|
||||||
|
|
||||||
```
|
|
||||||
TM_MAD_CONF = [
|
|
||||||
NAME = "vitastor", LN_TARGET = "NONE", CLONE_TARGET = "SELF", SHARED = "YES",
|
|
||||||
DS_MIGRATE = "NO", DRIVER = "raw", ALLOW_ORPHANS="format",
|
|
||||||
TM_MAD_SYSTEM = "ssh,shared", LN_TARGET_SSH = "SYSTEM", CLONE_TARGET_SSH = "SYSTEM",
|
|
||||||
DISK_TYPE_SSH = "FILE", LN_TARGET_SHARED = "NONE",
|
|
||||||
CLONE_TARGET_SHARED = "SELF", DISK_TYPE_SHARED = "FILE"
|
|
||||||
]
|
|
||||||
|
|
||||||
DS_MAD_CONF = [
|
|
||||||
NAME = "vitastor",
|
|
||||||
REQUIRED_ATTRS = "DISK_TYPE,BRIDGE_LIST",
|
|
||||||
PERSISTENT_ONLY = "NO",
|
|
||||||
MARKETPLACE_ACTIONS = "export"
|
|
||||||
]
|
|
||||||
```
|
|
||||||
|
|
||||||
## Создайте хранилища
|
|
||||||
|
|
||||||
Примеры настроек хранилищ образов (image) и дисков ВМ (system):
|
|
||||||
[opennebula/vitastor-imageds.conf](../../opennebula/vitastor-imageds.conf) и
|
|
||||||
[opennebula/vitastor-systemds.conf](../../opennebula/vitastor-systemds.conf).
|
|
||||||
|
|
||||||
Скопируйте настройки и поменяйте следующие параметры так, как вам необходимо:
|
|
||||||
|
|
||||||
- POOL_NAME - имя пула Vitastor для сохранения образов дисков.
|
|
||||||
- IMAGE_PREFIX - строка, добавляемая в начало имён образов дисков.
|
|
||||||
- BRIDGE_LIST - список серверов с доступом к кластеру Vitastor, используемых для операций с хранилищем образов (image, не system).
|
|
||||||
- VITASTOR_CONF - путь к конфигурации Vitastor. Имейте в виду, что этот путь также надо добавить в `/etc/apparmor.d/local/abstractions/libvirt-qemu`, если вы используете AppArmor.
|
|
||||||
- STAGING_DIR - путь к временному каталогу, используемому при импорте внешних образов. Должен иметь достаточно свободного места, чтобы вмещать скачанные образы.
|
|
||||||
|
|
||||||
После этого создайте хранилища с помощью команд `onedatastore create vitastor-imageds.conf` и `onedatastore create vitastor-systemds.conf` (либо через UI).
|
|
||||||
|
|
||||||
## Блокировка доступа ВМ в Vitastor
|
|
||||||
|
|
||||||
Vitastor пока не поддерживает никакую аутентификацию, так что вы ДОЛЖНЫ заблокировать доступ гостевых ВМ
|
|
||||||
в кластер Vitastor на сетевом уровне.
|
|
||||||
|
|
||||||
Если вы используете VLAN-сети для ВМ - удостоверьтесь, что ВМ и гипервизор/сеть хранения помещены в разные
|
|
||||||
изолированные друг от друга VLAN-ы.
|
|
||||||
|
|
||||||
Если вы используете что-то более примитивное, например, мосты (bridge), вам, скорее всего, придётся вручную
|
|
||||||
настроить iptables / межсетевой экран, чтобы разрешить доступ к Vitastor только с IP гипервизоров.
|
|
||||||
|
|
||||||
Также в этом случае нужно будет переключить обычные мосты на "Bridged & Security Groups" и включить фильтр
|
|
||||||
спуфинга IP в OpenNebula. Правда, реализация этого фильтра пока не полная, и она не блокирует доступ к
|
|
||||||
локальным интерфейсам гипервизора. То есть, включённый фильтр спуфинга IP запрещает ВМ отправлять трафик
|
|
||||||
с чужими IP к другим ВМ или во внешний мир, но не запрещает отправлять его напрямую гипервизору. Чтобы
|
|
||||||
исправить это, тоже нужны дополнительные правила iptables.
|
|
||||||
|
|
||||||
Таким образом, более-менее полная блокировка при использовании простой сети на сетевых мостах может
|
|
||||||
выглядеть так (здесь `10.0.3.0/24` - подсеть ВМ, `10.0.2.0/24` - подсеть гипервизора):
|
|
||||||
|
|
||||||
```
|
|
||||||
# Разрешаем входящий трафик с физического устройства
|
|
||||||
iptables -A INPUT -m physdev --physdev-in eth0 -j ACCEPT
|
|
||||||
# Запрещаем трафик со всех ВМ, но с IP не из подсети ВМ
|
|
||||||
iptables -A INPUT ! -s 10.0.3.0/24 -i onebr0 -j DROP
|
|
||||||
# Запрещаем трафик от ВМ к сети гипервизора
|
|
||||||
iptables -I FORWARD 1 -s 10.0.3.0/24 -d 10.0.2.0/24 -j DROP
|
|
||||||
```
|
|
||||||
|
|
||||||
## Тестирование
|
|
||||||
|
|
||||||
Плагин OpenNebula по большей части состоит из bash-скриптов, и чтобы было понятнее, что они
|
|
||||||
вообще делают - ниже приведены описания процедур, которыми можно протестировать каждый из них.
|
|
||||||
|
|
||||||
| Скрипт | Описание | Как протестировать |
|
|
||||||
| ----------------------- | --------------------------------------------- | ------------------------------------------------------------------------------------ |
|
|
||||||
| vmm/kvm/deploy.vitastor | Запустить виртуальную машину | Создайте и запустите виртуальную машину с дисками Vitastor: постоянным / непостоянным / волатильным (временным). |
|
|
||||||
| vmm/kvm/save.vitastor | Сохранить снимок памяти ВМ | Остановите виртуальную машину командой "Остановить". |
|
|
||||||
| vmm/kvm/restore.vitastor| Восстановить снимок памяти ВМ | Запустите ВМ после остановки обратно. |
|
|
||||||
| datastore/clone | Скопировать образ как "постоянный" | Создайте шаблон ВМ и создайте из него постоянную ВМ. |
|
|
||||||
| datastore/cp | Импортировать внешний образ | Импортируйте шаблон ВМ с образами дисков из Магазина OpenNebula. |
|
|
||||||
| datastore/export | Экспортировать образ как URL | Вероятно: экспортируйте шаблон ВМ с образами в Магазин. |
|
|
||||||
| datastore/mkfs | Создать образ с файловой системой | Хранилище → Образы → Создать → Тип: базовый блок данных, Расположение: пустой образ диска, Файловая система: любая непустая. |
|
|
||||||
| datastore/monitor | Вывод статистики места в хранилище образов | Проверьте статистику свободного/занятого места в списке хранилищ образов. |
|
|
||||||
| datastore/rm | Удалить "постоянный" образ | Хранилище → Образы → Выберите образ → Удалить. |
|
|
||||||
| datastore/snap_delete | Удалить снимок "постоянного" образа | Хранилище → Образы → Выберите образ → Выберите снимок → Удалить; <br> Чтобы создать образ со снимком: подключите постоянный образ к ВМ, создайте снимок, отключите образ. |
|
|
||||||
| datastore/snap_flatten | Откатить образ к снимку, удалив другие снимки | Хранилище → Образы → Выберите образ → Выберите снимок → "Выровнять" (flatten). |
|
|
||||||
| datastore/snap_revert | Откатить образ к снимку | Хранилище → Образы → Выберите образ → Выберите снимок → Откатить. |
|
|
||||||
| datastore/stat | Показать виртуальный размер образа в МБ | Неизвестно. По-видимому, в плагинах Vitastor и Ceph не используется. |
|
|
||||||
| tm/clone | Клонировать "непостоянный" образ в диск ВМ | Подключите "непостоянный" образ к ВМ. |
|
|
||||||
| tm/context | Создать диск контекстуализации ВМ | Создайте ВМ с контекстуализацией, как обычно. Но тестировать особенно нечего: в плагинах Vitastor и Ceph образ контекста хранится в локальной ФС гипервизора. |
|
|
||||||
| tm/cpds | Копировать диск ВМ/его снимок в новый образ | Выберите ВМ → Выберите диск → Опционально выберите снимок → "Сохранить как". |
|
|
||||||
| tm/delete | Удалить диск-клон или волатильный диск ВМ | Отключите волатильный или не-постоянный диск от ВМ. |
|
|
||||||
| tm/failmigrate | Обработать неудачную миграцию | Тестировать нечего. Скрипт пуст в плагинах Vitastor и Ceph. В других плагинах скрипт должен откатывать действия tm/premigrate. |
|
|
||||||
| tm/ln | Подключить "постоянный" образ к ВМ | Тестировать нечего. Скрипт пуст в плагинах Vitastor и Ceph. |
|
|
||||||
| tm/mkimage | Создать волатильный диск, без или с ФС | Подключите волатильный диск к ВМ, с или без файловой системы. |
|
|
||||||
| tm/mkswap | Создать волатильный диск подкачки | Подключите волатильный диск к ВМ, форматированный как диск подкачки (swap). |
|
|
||||||
| tm/monitor | Вывод статистики места в хранилище дисков ВМ | Проверьте статистику свободного/занятого места в списке хранилищ дисков ВМ. |
|
|
||||||
| tm/mv | Мигрировать диск ВМ между хостами | Мигрируйте ВМ между серверами. Правда, с точки зрения хранилища в плагинах Vitastor и Ceph этот скрипт ничего не делает. |
|
|
||||||
| tm/mvds | Отключить "постоянный" образ от ВМ | Тестировать нечего. Скрипт пуст в плагинах Vitastor и Ceph. В целом же скрипт обратный к tm/ln и в других хранилищах он может, например, копировать образ ВМ с диска гипервизора обратно в хранилище. |
|
|
||||||
| tm/postbackup | Выполняется после бэкапа | По-видимому, скрипт просто удаляет временные файлы после резервного копирования. Так что можно провести его и проверить, что на серверах не осталось временных файлов. |
|
|
||||||
| tm/postbackup_live | Выполняется после бэкапа запущенной ВМ | То же, что tm/postbackup, но для запущенной ВМ. |
|
|
||||||
| tm/postmigrate | Выполняется после миграции ВМ | Тестировать нечего. Однако, OpenNebula запускает скрипт только для системного хранилища, поэтому он вызывает аналогичные скрипты для хранилищ других дисков той же ВМ. Помимо этого в плагинах Vitastor и Ceph скрипт ничего не делает. |
|
|
||||||
| tm/prebackup | Выполнить резервное копирование дисков ВМ | Создайте хранилище резервных копий типа "rsync" → Забэкапьте в него ВМ. |
|
|
||||||
| tm/prebackup_live | То же самое для запущенной ВМ | То же, что tm/prebackup, но запускает fsfreeze/thaw (остановку доступа к дискам). Так что смысл теста - проведите резервное копирование и проверьте, что данные скопировались консистентно. |
|
|
||||||
| tm/premigrate | Выполняется перед миграцией ВМ | Тестировать нечего. Аналогично tm/postmigrate запускается только для системного хранилища. |
|
|
||||||
| tm/resize | Изменить размер диска ВМ | Выберите ВМ → Выберите непостоянный диск → Измените его размер. |
|
|
||||||
| tm/restore | Восстановить диски ВМ из бэкапа | Создайте хранилище резервных копий → Забэкапьте в него ВМ → Восстановите её обратно. |
|
|
||||||
| tm/snap_create | Создать снимок диска ВМ | Выберите ВМ → Выберите диск → Создайте снимок. |
|
|
||||||
| tm/snap_create_live | Создать снимок диска запущенной ВМ | Выберите запущенную ВМ → Выберите диск → Создайте снимок. |
|
|
||||||
| tm/snap_delete | Удалить снимок диска ВМ | Выберите ВМ → Выберите диск → Выберите снимок → Удалить. |
|
|
||||||
| tm/snap_revert | Откатить диск ВМ к снимку | Выберите ВМ → Выберите диск → Выберите снимок → Откатить. |
|
|
|
@ -16,6 +16,8 @@
|
||||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||||
- Add `-oldstable` to bookworm/bullseye/buster in this line to install the last
|
- Add `-oldstable` to bookworm/bullseye/buster in this line to install the last
|
||||||
stable version from 0.9.x branch instead of 1.x
|
stable version from 0.9.x branch instead of 1.x
|
||||||
|
- For Debian 10 (Buster) also enable backports repository:
|
||||||
|
`deb http://deb.debian.org/debian buster-backports main`
|
||||||
- Install packages: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu-system-x86`
|
- Install packages: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu-system-x86`
|
||||||
|
|
||||||
## CentOS
|
## CentOS
|
||||||
|
|
|
@ -16,6 +16,8 @@
|
||||||
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
|
||||||
- Добавьте `-oldstable` к слову bookworm/bullseye/buster в этой строке, чтобы
|
- Добавьте `-oldstable` к слову bookworm/bullseye/buster в этой строке, чтобы
|
||||||
установить последнюю стабильную версию из ветки 0.9.x вместо 1.x
|
установить последнюю стабильную версию из ветки 0.9.x вместо 1.x
|
||||||
|
- Для Debian 10 (Buster) также включите репозиторий backports:
|
||||||
|
`deb http://deb.debian.org/debian buster-backports main`
|
||||||
- Установите пакеты: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu-system-x86`
|
- Установите пакеты: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu-system-x86`
|
||||||
|
|
||||||
## CentOS
|
## CentOS
|
||||||
|
|
|
@ -17,10 +17,10 @@ To enable Vitastor support in Proxmox Virtual Environment (6.4-8.1 are supported
|
||||||
- Restart pvedaemon: `systemctl restart pvedaemon`
|
- Restart pvedaemon: `systemctl restart pvedaemon`
|
||||||
|
|
||||||
`/etc/pve/storage.cfg` example (the only required option is vitastor_pool, all others
|
`/etc/pve/storage.cfg` example (the only required option is vitastor_pool, all others
|
||||||
are listed below with their default values; `vitastor_ssd` is Proxmox storage pool id):
|
are listed below with their default values):
|
||||||
|
|
||||||
```
|
```
|
||||||
vitastor: vitastor_ssd
|
vitastor: vitastor
|
||||||
# pool to put new images into
|
# pool to put new images into
|
||||||
vitastor_pool testpool
|
vitastor_pool testpool
|
||||||
# path to the configuration file
|
# path to the configuration file
|
||||||
|
|
|
@ -16,10 +16,10 @@
|
||||||
- Перезапустите демон Proxmox: `systemctl restart pvedaemon`
|
- Перезапустите демон Proxmox: `systemctl restart pvedaemon`
|
||||||
|
|
||||||
Пример `/etc/pve/storage.cfg` (единственная обязательная опция - vitastor_pool, все остальные
|
Пример `/etc/pve/storage.cfg` (единственная обязательная опция - vitastor_pool, все остальные
|
||||||
перечислены внизу для понимания значений по умолчанию; `vitastor_ssd` - имя хранилища в Proxmox):
|
перечислены внизу для понимания значений по умолчанию):
|
||||||
|
|
||||||
```
|
```
|
||||||
vitastor: vitastor_ssd
|
vitastor: vitastor
|
||||||
# Пул, в который будут помещаться образы дисков
|
# Пул, в который будут помещаться образы дисков
|
||||||
vitastor_pool testpool
|
vitastor_pool testpool
|
||||||
# Путь к файлу конфигурации
|
# Путь к файлу конфигурации
|
||||||
|
|
|
@ -6,151 +6,19 @@
|
||||||
|
|
||||||
# Architecture
|
# Architecture
|
||||||
|
|
||||||
- [Server-side components](#server-side-components)
|
|
||||||
- [Basic concepts](#basic-concepts)
|
- [Basic concepts](#basic-concepts)
|
||||||
- [Client-side components](#client-side-components)
|
|
||||||
- [Additional utilities](#additional-utilities)
|
|
||||||
- [Overall read/write process](#overall-read-write-process)
|
|
||||||
- [Nuances of request handling](#nuances-of-request-handling)
|
|
||||||
- [Similarities to Ceph](#similarities-to-ceph)
|
- [Similarities to Ceph](#similarities-to-ceph)
|
||||||
- [Differences from Ceph](#differences-from-ceph)
|
- [Differences from Ceph](#differences-from-ceph)
|
||||||
- [Implementation Principles](#implementation-principles)
|
- [Implementation Principles](#implementation-principles)
|
||||||
|
|
||||||
## Server-side components
|
|
||||||
|
|
||||||
- **OSD** (Object Storage Daemon) is a process that directly works with the disk, stores data
|
|
||||||
and serves read/write requests. One OSD serves one disk (or one partition). OSDs talk to etcd
|
|
||||||
and to each other — they receive cluster state from etcd, and send read/write requests for
|
|
||||||
secondary copies of data to other OSDs.
|
|
||||||
- **etcd** — clustered key/value database, used as a reliable storage for configuration
|
|
||||||
and high-level cluster state. Etcd is the component that prevents splitbrain in the cluster.
|
|
||||||
Data blocks are not stored in etcd, etcd doesn't participate in data write or read path.
|
|
||||||
- **Монитор** — a separate node.js based daemon which monitors the cluster, calculates
|
|
||||||
required configuration changes and saves them to etcd, thus commanding OSDs to apply these
|
|
||||||
changes. Monitor also aggregates cluster statistics. OSD don't talk to monitor, monitor
|
|
||||||
only sends and receives data from etcd.
|
|
||||||
|
|
||||||
## Basic concepts
|
## Basic concepts
|
||||||
|
|
||||||
- **Pool** is a container for data that has equal redundancy scheme and disk placement rules.
|
- OSD (Object Storage Daemon) is a process that stores data and serves read/write requests.
|
||||||
- **PG (Placement Group)** is a "shard" of the cluster, subdivision unit that has its own
|
- PG (Placement Group) is a "shard" of the cluster, group of data stored on one set of replicas.
|
||||||
set of OSDs for data storage.
|
- Pool is a container for data that has equal redundancy scheme and placement rules.
|
||||||
- **Failure Domain** is a group of OSDs, from the simultaneous failure of which you are
|
- Monitor is a separate daemon that watches cluster state and handles failures.
|
||||||
protected by Vitastor. Default failure domain is "host" (server), but you choose a
|
- Failure Domain is a group of OSDs that you allow to fail. It's "host" by default.
|
||||||
larger (for example, a rack of servers) or smaller (a single drive) failure domain
|
- Placement Tree groups OSDs in a hierarchy to later split them into Failure Domains.
|
||||||
for every pool.
|
|
||||||
- **Placement Tree** (similar to Ceph CRUSH Tree) groups OSDs in a hierarchy to later
|
|
||||||
split them into Failure Domains.
|
|
||||||
|
|
||||||
## Client-side components
|
|
||||||
|
|
||||||
- **Client library** encapsulates client I/O logic. Client library connects to etcd and to all OSDs,
|
|
||||||
receives cluster state from etcd, sends read and write requests directly to all OSDs. Due
|
|
||||||
to the symmetric distributed architecture, all data blocks (each 128 KB by default) are placed
|
|
||||||
to different OSDs, but clients always know where each data block is stored and connect directly
|
|
||||||
to the right OSD.
|
|
||||||
|
|
||||||
All other client-side components are based on the client library:
|
|
||||||
|
|
||||||
- **[vitastor-cli](../usage/cli.en.md)** — command-line utility for cluster management.
|
|
||||||
Allows to view cluster state, manage pools and images, i.e. create, modify and remove
|
|
||||||
virtual disks, their snapshots and clones.
|
|
||||||
- **[QEMU driver](../usage/qemu.en.md)** — pluggable QEMU module allowing QEMU/KVM virtual
|
|
||||||
machines work with virtual Vitastor disks directly from userspace through the client library,
|
|
||||||
without the need to attach disks as kernel block devices. However, if you want to attach
|
|
||||||
disks, you can also do that with the same driver and [VDUSE](../usage/qemu.en.md#vduse).
|
|
||||||
- **[vitastor-nbd](../usage/nbd.en.md)** — utility that allows to attach Vitastor disks as
|
|
||||||
kernel block devices using NBD (Network Block Device), which works more like "BUSE"
|
|
||||||
(Block Device In Userspace). Vitastor doesn't have Linux kernel modules for the same task
|
|
||||||
(at least by now). NBD is an older, non-recommended way to attach disks — you should use
|
|
||||||
VDUSE whenever you can.
|
|
||||||
- **[CSI driver](../installation/kubernetes.en.md)** — driver for attaching Vitastor images
|
|
||||||
and VitastorFS subdirectories as Kubernetes persistent volumes. Block-based CSI uses
|
|
||||||
VDUSE (when available) or NBD — images are attached as kernel block devices and mounted
|
|
||||||
into containers. FS-based CSI uses **[vitastor-nfs](../usage/nfs.en.md)**.
|
|
||||||
- **Drivers for Proxmox, OpenStack and so on** — pluggable modules for corresponding systems,
|
|
||||||
allowing to use Vitastor as storage in them.
|
|
||||||
- **[vitastor-nfs](../usage/nfs.en.md)** — NFS 3.0 server allowing export of two file system variants:
|
|
||||||
the first is a simplified pseudo-FS for file-based access to Vitastor block images (for non-QEMU
|
|
||||||
hypervisors with NFS support), the second is **VitastorFS**, full-featured clustered POSIX FS.
|
|
||||||
Both variants support parallel access from multiple vitastor-nfs servers. In fact, you are
|
|
||||||
not required to setup separate NFS servers at all and use vitastor-nfs mount command on every
|
|
||||||
client node — it starts the NFS server and mounts the FS locally.
|
|
||||||
- **[fio driver](../usage/fio.en.md)** — pluggable module for fio disk benchmarking tool for
|
|
||||||
running performance tests on your Vitastor cluster.
|
|
||||||
- **vitastor-kv** — client for a key-value DB working over shared block volumes (usual
|
|
||||||
vitastor images). VitastorFS metadata is stored in vitastor-kv.
|
|
||||||
|
|
||||||
## Additional utilities
|
|
||||||
|
|
||||||
- **vitastor-disk** — a Vitastor OSD disk management tool. You can create, remove,
|
|
||||||
resize and move OSD partitions with it.
|
|
||||||
|
|
||||||
## Overall read/write process
|
|
||||||
|
|
||||||
- Vitastor stores virtual disks, also named "images" or "inodes".
|
|
||||||
- Each image is stored in some pool. Pool specifies storage parameters such as redundancy
|
|
||||||
scheme (replication or EC — erasure codes, i.e. error correction codes), failure domain
|
|
||||||
and restrictions on OSD selection for image data placement. See [Pool configuration](../config/pool.en.md) for details.
|
|
||||||
- Each image is split into objects/blocks of fixed size, equal to [block_size](../config/layout-cluster.en.md#block_size)
|
|
||||||
(128 KB by default), multiplied by data part count for EC or 1 for replicas. That is,
|
|
||||||
if a pool uses EC 4+2 coding scheme (4 data parts + 2 parity parts), then, with the
|
|
||||||
default block_size, images are split into 512 KB objects.
|
|
||||||
- Client read/write requests are split into parts at object boundaries.
|
|
||||||
- Each object is mapped to a PG number it belongs to, by simply taking a remainder of
|
|
||||||
division of its offset by PG count of the image's pool.
|
|
||||||
- Client reads primary OSD for all PGs from etcd. Primary OSD for each PG is assigned
|
|
||||||
by the monitor during cluster operation, along with the full PG OSD set.
|
|
||||||
- If not already connected, client connects to primary OSDs of all PGs involved in a
|
|
||||||
read/write request and sends parts of the request to them.
|
|
||||||
- If a primary OSD is unavailable, client retries connection attempts indefinitely
|
|
||||||
either until it becomes available or until the monitor assigns another OSD as primary
|
|
||||||
for that PG.
|
|
||||||
- Client also retries requests if the primary OSD replies with error code EPIPE, meaning
|
|
||||||
that the PG is inactive at this OSD at the moment - for example, when the primary OSD
|
|
||||||
is switched, or if the primary OSD itself loses connection to replicas during request
|
|
||||||
handling.
|
|
||||||
- Primary OSD determines where the parts of the object are stored. By default, all objects
|
|
||||||
are assumed to be stored at the target OSD set of a PG, but some of them may be present
|
|
||||||
at a different OSD set if they are degraded or moved, or if the data rebalancing process
|
|
||||||
is active. OSDs doesn't do any network requests, if calculates locations of all objects
|
|
||||||
during PG activation and stores it in memory.
|
|
||||||
- Primary OSD handles the request locally when it can - for example, when it's a read
|
|
||||||
from a replicated pool or when it's a read from a EC pool involving only one data part
|
|
||||||
stored on the OSD's local disk.
|
|
||||||
- When a request requires reads or writes to additional OSDs, primary OSD uses already
|
|
||||||
established connections to secondary OSDs of the PG to execute these requests. This happens
|
|
||||||
in parallel to local disk operations. All such connections are guaranteed to be already
|
|
||||||
established when the PG is active, and if any of them is dropped, PG is restarted and
|
|
||||||
all current read/write operations to it fail with EPIPE error and are retried by clients.
|
|
||||||
- After completing all secondary read/write requests, primary OSD sends the response to
|
|
||||||
the client.
|
|
||||||
|
|
||||||
### Nuances of request handling
|
|
||||||
|
|
||||||
- If a pool uses erasure codes and some of the OSDs are unavailable, primary OSDs recover
|
|
||||||
data from the remaining parts during read.
|
|
||||||
- Each object has a version number. During write, primary OSD first determines the current
|
|
||||||
version of the object. As primary OSD usually stores the object or its part itself, most
|
|
||||||
of the time version is read from the memory of the OSD itself. However, if primary OSD
|
|
||||||
doesn't contain parts of the object, it requests the version number from a secondary OSD
|
|
||||||
which has that part. Such request still doesn't involve reading from the disk though,
|
|
||||||
because object metadata, including version number, is always stored in OSD memory.
|
|
||||||
- If a pool uses erasure codes, partial writes of an object require reading other parts of
|
|
||||||
it from secondary OSDs or from the local disk of the primary OSD itself. This is called
|
|
||||||
"read-modify-write" process.
|
|
||||||
- If a pool uses erasure codes, two-phase write process is used to get rid of the Write Hole
|
|
||||||
problem: first a new version of object parts is written to all secondary OSDs without
|
|
||||||
removing the previous version, and then, after receiving successful write confirmations
|
|
||||||
from all OSDs, new version is committed and the old one is allowed to be removed.
|
|
||||||
- In a pool doesn't use immediate_commit mode, then write requests sent by clients aren't
|
|
||||||
treated as committed to physical media instantly. Clients have to send separate type of
|
|
||||||
requests (SYNC) to commit changes, and before it isn't sent, new versions of data are
|
|
||||||
allowed to be lost if some OSDs die. Thus, when immediate_commit is disabled, clients
|
|
||||||
store copies of all write requests in memory and repeat them from there when the
|
|
||||||
connection to primary OSD is lost. This in-memory copy is removed after a successful
|
|
||||||
SYNC, and to prevent excessive memory usage, clients also do an automatic SYNC
|
|
||||||
every [client_dirty_limit](../config/network.en.md#client_dirty_limit) written bytes.
|
|
||||||
|
|
||||||
## Similarities to Ceph
|
## Similarities to Ceph
|
||||||
|
|
||||||
|
@ -219,5 +87,5 @@ All other client-side components are based on the client library:
|
||||||
- Deleting images in a degraded cluster may currently lead to objects reappearing
|
- Deleting images in a degraded cluster may currently lead to objects reappearing
|
||||||
after dead OSDs come back, and in case of erasure-coded pools, they may even
|
after dead OSDs come back, and in case of erasure-coded pools, they may even
|
||||||
reappear as incomplete. Just repeat the removal request again in this case.
|
reappear as incomplete. Just repeat the removal request again in this case.
|
||||||
This problem will be fixed in the future, along with the metadata disk storage
|
This problem will be fixed in the nearest future, the fix is already implemented
|
||||||
format update.
|
in the "epoch-deletions" branch.
|
||||||
|
|
|
@ -11,7 +11,6 @@
|
||||||
- [Серверные компоненты](#серверные-компоненты)
|
- [Серверные компоненты](#серверные-компоненты)
|
||||||
- [Базовые понятия](#базовые-понятия)
|
- [Базовые понятия](#базовые-понятия)
|
||||||
- [Клиентские компоненты](#клиентские-компоненты)
|
- [Клиентские компоненты](#клиентские-компоненты)
|
||||||
- [Дополнительные утилиты](#дополнительные-утилиты)
|
|
||||||
- [Общий процесс записи и чтения](#общий-процесс-записи-и-чтения)
|
- [Общий процесс записи и чтения](#общий-процесс-записи-и-чтения)
|
||||||
- [Особенности обработки запросов](#особенности-обработки-запросов)
|
- [Особенности обработки запросов](#особенности-обработки-запросов)
|
||||||
- [Схожесть с Ceph](#схожесть-с-ceph)
|
- [Схожесть с Ceph](#схожесть-с-ceph)
|
||||||
|
@ -24,8 +23,8 @@
|
||||||
Один OSD управляет одним диском (или разделом). OSD общаются с etcd и друг с другом — от etcd они
|
Один OSD управляет одним диском (или разделом). OSD общаются с etcd и друг с другом — от etcd они
|
||||||
получают состояние кластера, а друг другу передают запросы записи и чтения вторичных копий данных.
|
получают состояние кластера, а друг другу передают запросы записи и чтения вторичных копий данных.
|
||||||
- **etcd** — кластерная key/value база данных, используется для хранения настроек и верхнеуровневого
|
- **etcd** — кластерная key/value база данных, используется для хранения настроек и верхнеуровневого
|
||||||
состояния кластера, а также предотвращения разделения сознания (splitbrain). Блоки данных в etcd не
|
состояния кластера, а также предотвращения разделения сознания. Блоки данных в etcd не хранятся,
|
||||||
хранятся, в обработке клиентских запросов чтения и записи etcd не участвует.
|
в обработке клиентских запросов чтения и записи etcd не участвует.
|
||||||
- **Монитор** — отдельный демон на node.js, рассчитывающий необходимые изменения в конфигурацию
|
- **Монитор** — отдельный демон на node.js, рассчитывающий необходимые изменения в конфигурацию
|
||||||
кластера, сохраняющий эту информацию в etcd и таким образом командующий OSD применить эти изменения.
|
кластера, сохраняющий эту информацию в etcd и таким образом командующий OSD применить эти изменения.
|
||||||
Также агрегирует статистику. Контактирует только с etcd, OSD с монитором не общаются.
|
Также агрегирует статистику. Контактирует только с etcd, OSD с монитором не общаются.
|
||||||
|
@ -35,56 +34,40 @@
|
||||||
- **Пул (Pool)** — контейнер для данных, имеющих одну и ту же схему избыточности и правила распределения по OSD.
|
- **Пул (Pool)** — контейнер для данных, имеющих одну и ту же схему избыточности и правила распределения по OSD.
|
||||||
- **PG (Placement Group)** — "шард", единица деления пулов в кластере, которой назначается свой набор
|
- **PG (Placement Group)** — "шард", единица деления пулов в кластере, которой назначается свой набор
|
||||||
OSD для хранения данных (копий или частей объектов).
|
OSD для хранения данных (копий или частей объектов).
|
||||||
- **Домен отказа (Failure Domain)** — группа OSD, от одновременного падения которых должен защищать
|
- **Домен отказа (Failure Domain)** — группа OSD, одновременное падение которых рассматривается
|
||||||
Vitastor. По умолчанию домен отказа — "host" (сервер), но вы можете установить для пула как больший
|
как вероятное. По умолчанию это "host" (сервер).
|
||||||
домен отказа (например, стойку серверов), так и меньший (например, отдельный диск).
|
|
||||||
- **Дерево распределения** (Placement Tree, в Ceph CRUSH Tree) — иерархическая группировка OSD
|
- **Дерево распределения** (Placement Tree, в Ceph CRUSH Tree) — иерархическая группировка OSD
|
||||||
в узлы, которые далее можно использовать как домены отказа.
|
в узлы, которые далее можно использовать как домены отказа.
|
||||||
|
|
||||||
## Клиентские компоненты
|
## Клиентские компоненты
|
||||||
|
|
||||||
- **Клиентская библиотека** — инкапсулирует логику на стороне клиента. Соединяется с etcd и со всеми OSD,
|
- **Клиентская библиотека** — инкапсулирует логику на стороне клиента. Соединяются с etcd и со всеми OSD,
|
||||||
от etcd получает состояние кластера, команды чтения и записи отправляет на все OSD напрямую.
|
от etcd получают состояние кластера, команды чтения и записи отправляют на все OSD напрямую.
|
||||||
В силу архитектуры все отдельные блоки данных (по умолчанию по 128 КБ) располагается на разных
|
В силу архитектуры все отдельные блоки данных (по умолчанию по 128 КБ) располагается на разных
|
||||||
OSD, но клиент устроен так, что всегда точно знает, к какому OSD обращаться, и подключается
|
OSD, но клиент устроен так, что всегда точно знает, к какому OSD обращаться, и подключается
|
||||||
к нему напрямую.
|
к нему напрямую.
|
||||||
|
|
||||||
На базе клиентской библиотеки реализованы все остальные клиенты:
|
На базе клиентской библиотеки реализованы все остальные клиенты:
|
||||||
|
|
||||||
- **[vitastor-cli](../usage/cli.ru.md)** — утилита командной строки для управления кластером.
|
- **vitastor-cli** — утилита командной строки для управления кластером. В данный момент позволяет
|
||||||
Позволяет просматривать общее состояние кластера, управлять пулами и образами — то есть
|
просматривать общее состояние кластера и управлять образами — т.е. создавать, менять и удалять
|
||||||
создавать, менять и удалять виртуальные диски, их снимки и клоны.
|
виртуальные диски, их снимки и клоны.
|
||||||
- **[Драйвер QEMU](../usage/qemu.ru.md)** — подключаемый модуль QEMU, позволяющий QEMU/KVM
|
- **Драйвер QEMU** — подключаемый модуль QEMU, позволяющий QEMU/KVM виртуальным машинам работать
|
||||||
виртуальным машинам работать с виртуальными дисками Vitastor напрямую из пространства пользователя
|
с виртуальными дисками Vitastor напрямую из пространства пользователя с помощью клиентской
|
||||||
с помощью клиентской библиотеки, без необходимости подключения дисков в виде блочных устройств
|
библиотеки, без необходимости отображения дисков в виде блочных устройств. Тот же драйвер
|
||||||
Linux. Если, однако, вы хотите подключать диски в виде блочных устройств, то вы тоже можете
|
позволяет подключать диски в систему через [VDUSE](../usage/qemu.ru.md#vduse).
|
||||||
сделать это с помощью того же самого драйвера и [VDUSE](../usage/qemu.ru.md#vduse).
|
- **vitastor-nbd** — утилита, позволяющая монтировать образы Vitastor в виде блочных устройств
|
||||||
- **[vitastor-nbd](../usage/nbd.ru.md)** — утилита, позволяющая монтировать образы Vitastor
|
с помощью NBD (Network Block Device), на самом деле скорее работающего как "BUSE"
|
||||||
в виде блочных устройств с помощью NBD (Network Block Device), на самом деле скорее работающего
|
(Block Device In Userspace). Модуля ядра Linux для выполнения той же задачи в Vitastor нет
|
||||||
как "BUSE" (Block Device In Userspace). Модуля ядра Linux для выполнения той же задачи в
|
(по крайней мере, пока).
|
||||||
Vitastor нет (по крайней мере, пока). NBD — более старый и нерекомендуемый способ подключения
|
- **CSI драйвер** — драйвер для подключения Vitastor-образов в виде персистентных томов (PV) Kubernetes.
|
||||||
дисков — вам следует использовать VDUSE всегда, когда это возможно.
|
Работает через vitastor-nbd — образы отражаются в виде блочных устройств и монтируются
|
||||||
- **[CSI драйвер](../installation/kubernetes.ru.md)** — драйвер для подключения Vitastor-образов
|
в контейнеры.
|
||||||
и поддиректорий VitastorFS в виде персистентных томов (PV) Kubernetes. Блочный CSI работает через
|
|
||||||
VDUSE (когда это возможно) или через NBD — образы отражаются в виде блочных устройств и монтируются
|
|
||||||
в контейнеры. Файловый CSI использует **[vitastor-nfs](../usage/nfs.ru.md)**.
|
|
||||||
- **Драйвера Proxmox, OpenStack и т.п.** — подключаемые модули для соответствующих систем,
|
- **Драйвера Proxmox, OpenStack и т.п.** — подключаемые модули для соответствующих систем,
|
||||||
позволяющие использовать Vitastor как хранилище в оных.
|
позволяющие использовать Vitastor как хранилище в оных.
|
||||||
- **[vitastor-nfs](../usage/nfs.ru.md)** — NFS 3.0 сервер, предоставляющий два варианта файловой системы:
|
- **vitastor-nfs** — утилита, предоставляющая файловый доступ к образам в кластере Vitastor
|
||||||
первая — упрощённая для файлового доступа к блочным образам (для не-QEMU гипервизоров, поддерживающих NFS),
|
по протоколу NFS 3.0. Предназначена для гипервизоров, не основанных на QEMU и Linux, но при
|
||||||
вторая — VitastorFS, полноценная кластерная POSIX ФС. Оба варианта поддерживают параллельный
|
этом поддерживающих NFS.
|
||||||
доступ с нескольких vitastor-nfs серверов. На самом деле можно вообще не выделять
|
|
||||||
отдельные NFS-серверы, а вместо этого использовать команду vitastor-nfs mount, запускающую
|
|
||||||
NFS-сервер прямо на клиентской машине и монтирующую ФС локально.
|
|
||||||
- **[Драйвер fio](../usage/fio.ru.md)** — подключаемый модуль для утилиты тестирования
|
|
||||||
производительности дисков fio, позволяющий тестировать Vitastor-кластеры.
|
|
||||||
- **vitastor-kv** — клиент для key-value базы данных, работающей поверх разделяемого блочного
|
|
||||||
образа (обычного блочного образа vitastor). Метаданные VitastorFS хранятся именно в vitastor-kv.
|
|
||||||
|
|
||||||
## Дополнительные утилиты
|
|
||||||
|
|
||||||
- **vitastor-disk** — утилита для разметки дисков под Vitastor OSD. С её помощью можно
|
|
||||||
создавать, удалять, менять размеры или перемещать разделы OSD.
|
|
||||||
|
|
||||||
## Общий процесс записи и чтения
|
## Общий процесс записи и чтения
|
||||||
|
|
||||||
|
@ -115,22 +98,16 @@
|
||||||
находиться на других OSD, если эти объекты деградированы или перемещены, или идёт процесс
|
находиться на других OSD, если эти объекты деградированы или перемещены, или идёт процесс
|
||||||
ребаланса. Запросы для проверки по сети не отправляются, информация о местоположении всех
|
ребаланса. Запросы для проверки по сети не отправляются, информация о местоположении всех
|
||||||
объектов рассчитывается первичным OSD при активации PG и хранится в памяти.
|
объектов рассчитывается первичным OSD при активации PG и хранится в памяти.
|
||||||
- Когда это возможно, первичный OSD обрабатывает запрос локально. Например, так происходит
|
- Первичный OSD соединяется (если ещё не соединён) с вторичными OSD, на которых располагаются
|
||||||
при чтениях объектов из пулов с репликацией или при чтении из EC пула, затрагивающего
|
части объекта, и отправляет им запросы чтения/записи, а также читает/пишет из/в своё локальное
|
||||||
только часть, хранимую на диске самого первичного OSD.
|
хранилище, если сам входит в набор.
|
||||||
- Когда запрос требует записи или чтения с вторичных OSD, первичный OSD использует заранее
|
|
||||||
установленные соединения с ними для выполнения этих запросов. Это происходит параллельно
|
|
||||||
локальным операциям чтения/записи с диска самого OSD. Так как соединения к вторичным OSD PG
|
|
||||||
устанавливаются при её запуске, то они уже гарантированно установлены, когда PG активна,
|
|
||||||
и если любое из этих соединений отключается, PG перезапускается, а все текущие запросы чтения
|
|
||||||
и записи в неё завершаются с ошибкой EPIPE, после чего повторяются клиентами.
|
|
||||||
- После завершения всех вторичных операций чтения/записи первичный OSD отправляет ответ клиенту.
|
- После завершения всех вторичных операций чтения/записи первичный OSD отправляет ответ клиенту.
|
||||||
|
|
||||||
### Особенности обработки запросов
|
### Особенности обработки запросов
|
||||||
|
|
||||||
- Если в пуле используются коды коррекции ошибок и при этом часть OSD недоступна, первичный
|
- Если в пуле используются коды коррекции ошибок и при этом часть OSD недоступна, первичный
|
||||||
OSD при чтении восстанавливает данные из оставшихся частей.
|
OSD при чтении восстанавливает данные из оставшихся частей.
|
||||||
- Каждый объект имеет номер версии. При записи объекта первичный OSD сначала получает номер
|
- Каждый объект имеет номер версии. При записи объекта первичный OSD сначала читает из номер
|
||||||
версии объекта. Так как первичный OSD обычно сам хранит копию или часть объекта, номер
|
версии объекта. Так как первичный OSD обычно сам хранит копию или часть объекта, номер
|
||||||
версии обычно читается из памяти самого OSD. Однако, если ни одна часть обновляемого объекта
|
версии обычно читается из памяти самого OSD. Однако, если ни одна часть обновляемого объекта
|
||||||
не находится на первичном OSD, для получения номера версии он обращается к одному из вторичных
|
не находится на первичном OSD, для получения номера версии он обращается к одному из вторичных
|
||||||
|
@ -138,20 +115,20 @@
|
||||||
так как метаданные объектов, включая номер версии, все OSD хранят в памяти.
|
так как метаданные объектов, включая номер версии, все OSD хранят в памяти.
|
||||||
- Если в пуле используются коды коррекции ошибок, перед частичной записью объекта для вычисления
|
- Если в пуле используются коды коррекции ошибок, перед частичной записью объекта для вычисления
|
||||||
чётности зачастую требуется чтение частей объекта с вторичных OSD или с локального диска
|
чётности зачастую требуется чтение частей объекта с вторичных OSD или с локального диска
|
||||||
самого первичного OSD. Это называется процессом "чтение-модификация-запись" (read-modify-write).
|
самого первичного OSD.
|
||||||
- Если в пуле используются коды коррекции ошибок, для закрытия Write Hole применяется
|
- Также, если в пуле используются коды коррекции ошибок, для закрытия Write Hole применяется
|
||||||
двухфазный алгоритм записи: сначала на все вторичные OSD записывается новая версия частей
|
двухфазный алгоритм записи: сначала на все вторичные OSD записывается новая версия частей
|
||||||
объекта, но при этом старая версия не удаляется, а потом, после получения подтверждения
|
объекта, но при этом старая версия не удаляется, а потом, после получения подтверждения
|
||||||
успешной записи от всех вторичных OSD, новая версия фиксируется и разрешается удаление старой.
|
успешной записи от всех вторичных OSD, новая версия фиксируется и разрешается удаление старой.
|
||||||
- Если в пуле не включён режим immediate_commit, то запросы записи, отправляемые клиентами,
|
- Если в кластере не включён режим immediate_commit, то запросы записи, отправляемые клиентами,
|
||||||
не считаются зафиксированными на физических накопителях сразу. Для фиксации данных клиенты
|
не считаются зафиксированными на физических накопителях сразу. Для фиксации данных клиенты
|
||||||
должны отдельно отправлять запросы SYNC (отдельный от чтения и записи вид запроса),
|
должны отдельно отправлять запросы SYNC (отдельный от чтения и записи вид запроса),
|
||||||
а пока такой запрос не отправлен, считается, что записанные данные могут исчезнуть,
|
а пока такой запрос не отправлен, считается, что записанные данные могут исчезнуть,
|
||||||
если соответствующий OSD упадёт. Поэтому, когда режим immediate_commit отключён, все
|
если соответствующий OSD упадёт. Поэтому, когда режим immediate_commit отключён, все
|
||||||
запросы записи клиенты копируют в памяти и при потере соединения и повторном соединении
|
запросы записи клиенты копируют в памяти и при потере соединения и повторном соединении
|
||||||
с OSD повторяют из памяти. Скопированные в память данные удаляются при успешном SYNC,
|
с OSD повторяют из памяти. Скопированные в память данные удаляются при успешном fsync,
|
||||||
а чтобы хранение этих данных не приводило к чрезмерному потреблению памяти, клиенты
|
а чтобы хранение этих данных не приводило к чрезмерному потреблению памяти, клиенты
|
||||||
автоматически выполняют SYNC каждые [client_dirty_limit](../config/network.ru.md#client_dirty_limit)
|
автоматически выполняют fsync каждые [client_dirty_limit](../config/network.ru.md#client_dirty_limit)
|
||||||
записанных байт.
|
записанных байт.
|
||||||
|
|
||||||
## Схожесть с Ceph
|
## Схожесть с Ceph
|
||||||
|
@ -228,5 +205,5 @@
|
||||||
- Удаление образов в деградированном кластере может в данный момент приводить к повторному
|
- Удаление образов в деградированном кластере может в данный момент приводить к повторному
|
||||||
"появлению" удалённых объектов после поднятия отключённых OSD, причём в случае EC-пулов,
|
"появлению" удалённых объектов после поднятия отключённых OSD, причём в случае EC-пулов,
|
||||||
объекты могут появиться в виде "неполных". Если вы столкнётесь с такой ситуацией, просто
|
объекты могут появиться в виде "неполных". Если вы столкнётесь с такой ситуацией, просто
|
||||||
повторите запрос удаления. Данная проблема будет исправлена в будущем вместе с обновлением
|
повторите запрос удаления. Исправление этой проблемы уже реализовано в ветке "epoch-deletions"
|
||||||
дискового формата хранения метаданных.
|
и вскоре будет включено в релиз.
|
||||||
|
|
|
@ -34,16 +34,9 @@
|
||||||
- [Client write-back cache](../config/client.en.md#client_enable_writeback)
|
- [Client write-back cache](../config/client.en.md#client_enable_writeback)
|
||||||
- [Intelligent recovery auto-tuning](../config/osd.en.md#recovery_tune_interval)
|
- [Intelligent recovery auto-tuning](../config/osd.en.md#recovery_tune_interval)
|
||||||
- [Clustered file system](../usage/nfs.en.md#vitastorfs)
|
- [Clustered file system](../usage/nfs.en.md#vitastorfs)
|
||||||
- [Experimental internal etcd replacement - antietcd](../config/monitor.en.md#use_antietcd)
|
|
||||||
- [Built-in Prometheus metric exporter](../config/monitor.en.md#enable_prometheus)
|
|
||||||
- [NFS RDMA support](../usage/nfs.en.md#rdma) (probably also usable for GPUDirect)
|
|
||||||
|
|
||||||
## Plugins and tools
|
## Plugins and tools
|
||||||
|
|
||||||
- [Proxmox storage plugin and packages](../installation/proxmox.en.md)
|
|
||||||
- [OpenNebula storage plugin](../installation/opennebula.en.md)
|
|
||||||
- [CSI plugin for Kubernetes](../installation/kubernetes.en.md)
|
|
||||||
- [OpenStack support: Cinder driver, Nova and libvirt patches](../installation/openstack.en.md)
|
|
||||||
- [Debian and CentOS packages](../installation/packages.en.md)
|
- [Debian and CentOS packages](../installation/packages.en.md)
|
||||||
- [Image management CLI (vitastor-cli)](../usage/cli.en.md)
|
- [Image management CLI (vitastor-cli)](../usage/cli.en.md)
|
||||||
- [Disk management CLI (vitastor-disk)](../usage/disk.en.md)
|
- [Disk management CLI (vitastor-disk)](../usage/disk.en.md)
|
||||||
|
@ -51,6 +44,9 @@
|
||||||
- [Native QEMU driver](../usage/qemu.en.md)
|
- [Native QEMU driver](../usage/qemu.en.md)
|
||||||
- [Loadable fio engine for benchmarks](../usage/fio.en.md)
|
- [Loadable fio engine for benchmarks](../usage/fio.en.md)
|
||||||
- [NBD proxy for kernel mounts](../usage/nbd.en.md)
|
- [NBD proxy for kernel mounts](../usage/nbd.en.md)
|
||||||
|
- [CSI plugin for Kubernetes](../installation/kubernetes.en.md)
|
||||||
|
- [OpenStack support: Cinder driver, Nova and libvirt patches](../installation/openstack.en.md)
|
||||||
|
- [Proxmox storage plugin and packages](../installation/proxmox.en.md)
|
||||||
- [Simplified NFS proxy for file-based image access emulation (suitable for VMWare)](../usage/nfs.en.md#pseudo-fs)
|
- [Simplified NFS proxy for file-based image access emulation (suitable for VMWare)](../usage/nfs.en.md#pseudo-fs)
|
||||||
|
|
||||||
## Roadmap
|
## Roadmap
|
||||||
|
@ -60,6 +56,7 @@ The following features are planned for the future:
|
||||||
- Control plane optimisation
|
- Control plane optimisation
|
||||||
- Other administrative tools
|
- Other administrative tools
|
||||||
- Web GUI
|
- Web GUI
|
||||||
|
- OpenNebula plugin
|
||||||
- iSCSI and NVMeoF gateways
|
- iSCSI and NVMeoF gateways
|
||||||
- Multi-threaded client
|
- Multi-threaded client
|
||||||
- Faster failover
|
- Faster failover
|
||||||
|
|
|
@ -36,16 +36,9 @@
|
||||||
- [Буферизация записи на стороне клиента](../config/client.ru.md#client_enable_writeback)
|
- [Буферизация записи на стороне клиента](../config/client.ru.md#client_enable_writeback)
|
||||||
- [Интеллектуальная автоподстройка скорости восстановления](../config/osd.ru.md#recovery_tune_interval)
|
- [Интеллектуальная автоподстройка скорости восстановления](../config/osd.ru.md#recovery_tune_interval)
|
||||||
- [Кластерная файловая система](../usage/nfs.ru.md#vitastorfs)
|
- [Кластерная файловая система](../usage/nfs.ru.md#vitastorfs)
|
||||||
- [Экспериментальная встроенная замена etcd - antietcd](../config/monitor.ru.md#use_antietcd)
|
|
||||||
- [Встроенный Prometheus-экспортер метрик](../config/monitor.ru.md#enable_prometheus)
|
|
||||||
- [Поддержка NFS RDMA](../usage/nfs.ru.md#rdma) (вероятно, также подходящая для GPUDirect)
|
|
||||||
|
|
||||||
## Драйверы и инструменты
|
## Драйверы и инструменты
|
||||||
|
|
||||||
- [Плагин для Proxmox](../installation/proxmox.ru.md)
|
|
||||||
- [Плагин для OpenNebula](../installation/opennebula.ru.md)
|
|
||||||
- [CSI-плагин для Kubernetes](../installation/kubernetes.ru.md)
|
|
||||||
- [Базовая поддержка OpenStack: драйвер Cinder, патчи для Nova и libvirt](../installation/openstack.ru.md)
|
|
||||||
- [Пакеты для Debian и CentOS](../installation/packages.ru.md)
|
- [Пакеты для Debian и CentOS](../installation/packages.ru.md)
|
||||||
- [Консольный интерфейс управления образами (vitastor-cli)](../usage/cli.ru.md)
|
- [Консольный интерфейс управления образами (vitastor-cli)](../usage/cli.ru.md)
|
||||||
- [Инструмент управления дисками (vitastor-disk)](../usage/disk.ru.md)
|
- [Инструмент управления дисками (vitastor-disk)](../usage/disk.ru.md)
|
||||||
|
@ -53,6 +46,9 @@
|
||||||
- [Драйвер диска для QEMU](../usage/qemu.ru.md)
|
- [Драйвер диска для QEMU](../usage/qemu.ru.md)
|
||||||
- [Драйвер диска для утилиты тестирования производительности fio](../usage/fio.ru.md)
|
- [Драйвер диска для утилиты тестирования производительности fio](../usage/fio.ru.md)
|
||||||
- [NBD-прокси для монтирования образов ядром](../usage/nbd.ru.md) ("блочное устройство в режиме пользователя")
|
- [NBD-прокси для монтирования образов ядром](../usage/nbd.ru.md) ("блочное устройство в режиме пользователя")
|
||||||
|
- [CSI-плагин для Kubernetes](../installation/kubernetes.ru.md)
|
||||||
|
- [Базовая поддержка OpenStack: драйвер Cinder, патчи для Nova и libvirt](../installation/openstack.ru.md)
|
||||||
|
- [Плагин для Proxmox](../installation/proxmox.ru.md)
|
||||||
- [Упрощённая NFS-прокси для эмуляции файлового доступа к образам (подходит для VMWare)](../usage/nfs.ru.md#псевдо-фс)
|
- [Упрощённая NFS-прокси для эмуляции файлового доступа к образам (подходит для VMWare)](../usage/nfs.ru.md#псевдо-фс)
|
||||||
|
|
||||||
## Планы развития
|
## Планы развития
|
||||||
|
@ -60,6 +56,7 @@
|
||||||
- Оптимизация слоя управления
|
- Оптимизация слоя управления
|
||||||
- Другие инструменты администрирования
|
- Другие инструменты администрирования
|
||||||
- Web-интерфейс
|
- Web-интерфейс
|
||||||
|
- Плагин для OpenNebula
|
||||||
- iSCSI и NVMeoF прокси
|
- iSCSI и NVMeoF прокси
|
||||||
- Многопоточный клиент
|
- Многопоточный клиент
|
||||||
- Более быстрое переключение при отказах
|
- Более быстрое переключение при отказах
|
||||||
|
|
|
@ -22,7 +22,7 @@
|
||||||
with lazy fsync, but prepare for inferior single-thread latency. Read more about capacitors
|
with lazy fsync, but prepare for inferior single-thread latency. Read more about capacitors
|
||||||
[here](../config/layout-cluster.en.md#immediate_commit).
|
[here](../config/layout-cluster.en.md#immediate_commit).
|
||||||
- If you want to use HDDs, get modern HDDs with Media Cache or SSD Cache: HGST Ultrastar,
|
- If you want to use HDDs, get modern HDDs with Media Cache or SSD Cache: HGST Ultrastar,
|
||||||
Toshiba MG, Seagate EXOS or something similar. If your drives don't have such cache then
|
Toshiba MG08, Seagate EXOS or something similar. If your drives don't have such cache then
|
||||||
you also need small SSDs for journal and metadata (even 2 GB per 1 TB of HDD space is enough).
|
you also need small SSDs for journal and metadata (even 2 GB per 1 TB of HDD space is enough).
|
||||||
- Get a fast network (at least 10 Gbit/s). Something like Mellanox ConnectX-4 with RoCEv2 is ideal.
|
- Get a fast network (at least 10 Gbit/s). Something like Mellanox ConnectX-4 with RoCEv2 is ideal.
|
||||||
- Disable CPU powersaving: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
- Disable CPU powersaving: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||||
|
@ -32,8 +32,8 @@
|
||||||
|
|
||||||
- SATA SSD: Micron 5100/5200/5300/5400, Samsung PM863/PM883/PM893, Intel D3-S4510/4520/4610/4620, Kingston DC500M
|
- SATA SSD: Micron 5100/5200/5300/5400, Samsung PM863/PM883/PM893, Intel D3-S4510/4520/4610/4620, Kingston DC500M
|
||||||
- NVMe: Micron 9100/9200/9300/9400, Micron 7300/7450, Samsung PM983/PM9A3, Samsung PM1723/1735/1743,
|
- NVMe: Micron 9100/9200/9300/9400, Micron 7300/7450, Samsung PM983/PM9A3, Samsung PM1723/1735/1743,
|
||||||
Intel DC-P3700/P4500/P4600, Intel D5-P4320, Intel D7-P5500/P5600, Intel Optane, Kingston DC1000B/DC1500M
|
Intel DC-P3700/P4500/P4600, Intel D7-P5500/P5600, Intel Optane, Kingston DC1000B/DC1500M
|
||||||
- HDD: HGST Ultrastar, Toshiba MG, Seagate EXOS
|
- HDD: HGST Ultrastar, Toshiba MG06/MG07/MG08, Seagate EXOS
|
||||||
|
|
||||||
## Configure monitors
|
## Configure monitors
|
||||||
|
|
||||||
|
@ -68,6 +68,10 @@ On the monitor hosts:
|
||||||
but some free unpartitioned space must be available because the script creates new partitions for journals.
|
but some free unpartitioned space must be available because the script creates new partitions for journals.
|
||||||
- You can change OSD configuration in units or in `vitastor.conf`.
|
- You can change OSD configuration in units or in `vitastor.conf`.
|
||||||
Check [Configuration Reference](../config.en.md) for parameter descriptions.
|
Check [Configuration Reference](../config.en.md) for parameter descriptions.
|
||||||
|
- If all your drives have capacitors, and even if not, but if you ran `vitastor-disk`
|
||||||
|
without `--disable_data_fsync off` at the first step, then put the following
|
||||||
|
setting into etcd: \
|
||||||
|
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
|
||||||
- Start all OSDs: `systemctl start vitastor.target`
|
- Start all OSDs: `systemctl start vitastor.target`
|
||||||
|
|
||||||
## Create a pool
|
## Create a pool
|
||||||
|
@ -84,10 +88,6 @@ For EC pools the configuration should look like the following:
|
||||||
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
||||||
```
|
```
|
||||||
|
|
||||||
Add `--immediate_commit none` if you added `--disable_data_fsync off` at the OSD
|
|
||||||
initialization step, or if `vitastor-disk` complained about impossibility to
|
|
||||||
disable drive cache.
|
|
||||||
|
|
||||||
After you do this, one of the monitors will configure PGs and OSDs will start them.
|
After you do this, one of the monitors will configure PGs and OSDs will start them.
|
||||||
|
|
||||||
If you use HDDs you should also add `"block_size": 1048576` to pool configuration.
|
If you use HDDs you should also add `"block_size": 1048576` to pool configuration.
|
||||||
|
|
|
@ -22,7 +22,7 @@
|
||||||
использовать и десктопные SSD, включив режим отложенного fsync, но производительность будет хуже.
|
использовать и десктопные SSD, включив режим отложенного fsync, но производительность будет хуже.
|
||||||
О конденсаторах читайте [здесь](../config/layout-cluster.ru.md#immediate_commit).
|
О конденсаторах читайте [здесь](../config/layout-cluster.ru.md#immediate_commit).
|
||||||
- Если хотите использовать HDD, берите современные модели с Media или SSD кэшем - HGST Ultrastar,
|
- Если хотите использовать HDD, берите современные модели с Media или SSD кэшем - HGST Ultrastar,
|
||||||
Toshiba MG, Seagate EXOS или что-то похожее. Если такого кэша у ваших дисков нет,
|
Toshiba MG08, Seagate EXOS или что-то похожее. Если такого кэша у ваших дисков нет,
|
||||||
обязательно возьмите SSD под метаданные и журнал (маленькие, буквально 2 ГБ на 1 ТБ HDD-места).
|
обязательно возьмите SSD под метаданные и журнал (маленькие, буквально 2 ГБ на 1 ТБ HDD-места).
|
||||||
- Возьмите быструю сеть, минимум 10 гбит/с. Идеал - что-то вроде Mellanox ConnectX-4 с RoCEv2.
|
- Возьмите быструю сеть, минимум 10 гбит/с. Идеал - что-то вроде Mellanox ConnectX-4 с RoCEv2.
|
||||||
- Для лучшей производительности отключите энергосбережение CPU: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
- Для лучшей производительности отключите энергосбережение CPU: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
|
||||||
|
@ -32,8 +32,8 @@
|
||||||
|
|
||||||
- SATA SSD: Micron 5100/5200/5300/5400, Samsung PM863/PM883/PM893, Intel D3-S4510/4520/4610/4620, Kingston DC500M
|
- SATA SSD: Micron 5100/5200/5300/5400, Samsung PM863/PM883/PM893, Intel D3-S4510/4520/4610/4620, Kingston DC500M
|
||||||
- NVMe: Micron 9100/9200/9300/9400, Micron 7300/7450, Samsung PM983/PM9A3, Samsung PM1723/1735/1743,
|
- NVMe: Micron 9100/9200/9300/9400, Micron 7300/7450, Samsung PM983/PM9A3, Samsung PM1723/1735/1743,
|
||||||
Intel DC-P3700/P4500/P4600, Intel D5-P4320, Intel D7-P5500/P5600, Intel Optane, Kingston DC1000B/DC1500M
|
Intel DC-P3700/P4500/P4600, Intel D7-P5500/P5600, Intel Optane, Kingston DC1000B/DC1500M
|
||||||
- HDD: HGST Ultrastar, Toshiba MG, Seagate EXOS
|
- HDD: HGST Ultrastar, Toshiba MG06/MG07/MG08, Seagate EXOS
|
||||||
|
|
||||||
## Настройте мониторы
|
## Настройте мониторы
|
||||||
|
|
||||||
|
@ -69,6 +69,11 @@
|
||||||
для журналов, на SSD должно быть доступно свободное нераспределённое место.
|
для журналов, на SSD должно быть доступно свободное нераспределённое место.
|
||||||
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Описания параметров
|
- Вы можете менять параметры OSD в юнитах systemd или в `vitastor.conf`. Описания параметров
|
||||||
смотрите в [справке по конфигурации](../config.ru.md).
|
смотрите в [справке по конфигурации](../config.ru.md).
|
||||||
|
- Если все ваши диски - серверные с конденсаторами, и даже если нет, но при этом
|
||||||
|
вы не добавляли опцию `--disable_data_fsync off` на первом шаге, а `vitastor-disk`
|
||||||
|
не ругался на невозможность отключения кэша дисков, пропишите следующую настройку
|
||||||
|
в глобальную конфигурацию в etcd: \
|
||||||
|
`etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`.
|
||||||
- Запустите все OSD: `systemctl start vitastor.target`
|
- Запустите все OSD: `systemctl start vitastor.target`
|
||||||
|
|
||||||
## Создайте пул
|
## Создайте пул
|
||||||
|
@ -85,10 +90,6 @@ vitastor-cli create-pool testpool --pg_size 2 --pg_count 256
|
||||||
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
vitastor-cli create-pool testpool --ec 2+2 --pg_count 256
|
||||||
```
|
```
|
||||||
|
|
||||||
Добавьте также опцию `--immediate_commit none`, если вы добавляли `--disable_data_fsync off`
|
|
||||||
на этапе инициализации OSD, либо если `vitastor-disk` ругался на невозможность отключения
|
|
||||||
кэша дисков.
|
|
||||||
|
|
||||||
После этого один из мониторов должен сконфигурировать PG, а OSD должны запустить их.
|
После этого один из мониторов должен сконфигурировать PG, а OSD должны запустить их.
|
||||||
|
|
||||||
Если вы используете HDD-диски, то добавьте в конфигурацию пулов опцию `"block_size": 1048576`.
|
Если вы используете HDD-диски, то добавьте в конфигурацию пулов опцию `"block_size": 1048576`.
|
||||||
|
@ -122,4 +123,4 @@ vitastor-cli create -s 10G testimg
|
||||||
Если вы хотите использовать не только блочные образы виртуальных машин или контейнеров,
|
Если вы хотите использовать не только блочные образы виртуальных машин или контейнеров,
|
||||||
а также кластерную файловую систему, то:
|
а также кластерную файловую систему, то:
|
||||||
|
|
||||||
- [Следуйте инструкциям](../usage/nfs.ru.md#vitastorfs)
|
- [Следуйте инструкциям](../usage/nfs.en.md#vitastorfs)
|
||||||
|
|
|
@ -42,7 +42,7 @@ PG state always includes exactly 1 of the following base states:
|
||||||
- **offline** — PG isn't activated by any OSD at all. Either primary OSD isn't set for
|
- **offline** — PG isn't activated by any OSD at all. Either primary OSD isn't set for
|
||||||
this PG at all (if the pool is just created), or an unavailable OSD is set as primary,
|
this PG at all (if the pool is just created), or an unavailable OSD is set as primary,
|
||||||
or the primary OSD refuses to start this PG (for example, because of wrong block_size),
|
or the primary OSD refuses to start this PG (for example, because of wrong block_size),
|
||||||
or the PG is stopped by the monitor using `pause: true` flag in `/vitastor/pg/config` in etcd.
|
or the PG is stopped by the monitor using `pause: true` flag in `/vitastor/config/pgs` in etcd.
|
||||||
- **starting** — primary OSD has acquired PG lock in etcd, PG is starting.
|
- **starting** — primary OSD has acquired PG lock in etcd, PG is starting.
|
||||||
- **peering** — primary OSD requests PG object listings from secondary OSDs and calculates
|
- **peering** — primary OSD requests PG object listings from secondary OSDs and calculates
|
||||||
the PG state.
|
the PG state.
|
||||||
|
@ -58,9 +58,8 @@ and during switching primary OSD of PGs.
|
||||||
|
|
||||||
**starting**, **repeering**, **stopping** states normally almost aren't visible at all.
|
**starting**, **repeering**, **stopping** states normally almost aren't visible at all.
|
||||||
If you notice them for any noticeable time — chances are some operations on some OSDs hung.
|
If you notice them for any noticeable time — chances are some operations on some OSDs hung.
|
||||||
Check `vitastor-cli status` and search for "slow op" in OSD logs to find them — operations
|
Search for "slow op" in OSD logs to find them — operations hung for more than
|
||||||
hung for more than [slow_log_interval](../config/osd.en.md#slow_log_interval) are logged as
|
[slow_log_interval](../config/osd.en.md#slow_log_interval) are logged as "slow ops".
|
||||||
"slow ops" and displayed in `status`.
|
|
||||||
|
|
||||||
State transition diagram:
|
State transition diagram:
|
||||||
|
|
||||||
|
@ -108,17 +107,16 @@ If a PG is active it can also have any number of the following additional states
|
||||||
|
|
||||||
## Removing a healthy disk
|
## Removing a healthy disk
|
||||||
|
|
||||||
Before removing a healthy disk from the cluster set its OSD weight(s) to 0 to
|
Befor removing a healthy disk from the cluster set its OSD weight(s) to 0 to
|
||||||
move data away. To do that, run `vitastor-cli modify-osd --reweight 0 <НОМЕР_OSD>`.
|
move data away. To do that, add `"reweight":0` to etcd key `/vitastor/config/osd/<OSD_NUMBER>`.
|
||||||
|
For example:
|
||||||
Then wait until rebalance finishes and remove OSD by running `vitastor-disk purge /dev/vitastor/osdN-data`.
|
|
||||||
|
|
||||||
Zero weight can also be put manually into etcd key `/vitastor/config/osd/<НОМЕР_OSD>`, for example:
|
|
||||||
|
|
||||||
```
|
```
|
||||||
etcdctl --endpoints=http://1.1.1.1:2379/v3 put /vitastor/config/osd/1 '{"reweight":0}'
|
etcdctl --endpoints=http://1.1.1.1:2379/v3 put /vitastor/config/osd/1 '{"reweight":0}'
|
||||||
```
|
```
|
||||||
|
|
||||||
|
Then wait until rebalance finishes and remove OSD by running `vitastor-disk purge /dev/vitastor/osdN-data`.
|
||||||
|
|
||||||
## Removing a failed disk
|
## Removing a failed disk
|
||||||
|
|
||||||
If a disk is already dead, its OSD(s) are likely already stopped.
|
If a disk is already dead, its OSD(s) are likely already stopped.
|
||||||
|
@ -151,7 +149,7 @@ POOL_ID=1
|
||||||
ALL_OSDS=$(etcdctl --endpoints=your_etcd_address:2379 get --keys-only --prefix /vitastor/osd/stats/ | \
|
ALL_OSDS=$(etcdctl --endpoints=your_etcd_address:2379 get --keys-only --prefix /vitastor/osd/stats/ | \
|
||||||
perl -e '$/ = undef; $a = <>; $a =~ s/\s*$//; $a =~ s!/vitastor/osd/stats/!!g; $a =~ s/\s+/,/g; print $a')
|
perl -e '$/ = undef; $a = <>; $a =~ s/\s*$//; $a =~ s!/vitastor/osd/stats/!!g; $a =~ s/\s+/,/g; print $a')
|
||||||
for i in $(seq 1 $PG_COUNT); do
|
for i in $(seq 1 $PG_COUNT); do
|
||||||
etcdctl --endpoints=your_etcd_address:2379 put /vitastor/pg/history/$POOL_ID/$i '{"all_peers":['$ALL_OSDS']}'
|
etcdctl --endpoints=your_etcd_address:2379 put /vitastor/pg/history/$POOL_ID/$i '{"all_peers":['$ALL_OSDS']}'; done
|
||||||
done
|
done
|
||||||
```
|
```
|
||||||
|
|
||||||
|
@ -170,70 +168,21 @@ Upgrading is performed without stopping clients (VMs/containers), you just need
|
||||||
upgrade and restart servers one by one. However, ideally you should restart VMs too
|
upgrade and restart servers one by one. However, ideally you should restart VMs too
|
||||||
to make them use the new version of the client library.
|
to make them use the new version of the client library.
|
||||||
|
|
||||||
### 1.7.x to 1.8.0
|
Exceptions (specific upgrade instructions):
|
||||||
|
- Upgrading <= 1.1.x to 1.2.0 or later, if you use EC n+k with k>=2, is recommended
|
||||||
|
to be performed with full downtime: first you should stop all clients, then all OSDs,
|
||||||
|
then upgrade and start everything back — because versions before 1.2.0 have several
|
||||||
|
bugs leading to invalid data being read in EC n+k, k>=2 configurations in degraded pools.
|
||||||
|
- Versions <= 0.8.7 are incompatible with versions >= 0.9.0, so you should first
|
||||||
|
upgrade from <= 0.8.7 to 0.8.8 or 0.8.9, and only then to >= 0.9.x. If you upgrade
|
||||||
|
without this intermediate step, client I/O will hang until the end of upgrade process.
|
||||||
|
- Upgrading from <= 0.5.x to >= 0.6.x is not supported.
|
||||||
|
|
||||||
It's recommended to upgrade from version <= 1.7.x to version >= 1.8.0 with full downtime,
|
Rollback:
|
||||||
i.e. you should first stop clients and then the cluster (OSDs and monitor), because 1.8.0
|
- Version 1.0.0 has a new disk format, so OSDs initiaziled on 1.0.0 can't be rolled
|
||||||
includes a fix for etcd event stream inconsistency which could lead to "incomplete" objects
|
back to 0.9.x or previous versions.
|
||||||
appearing in EC pools, and in rare cases, probably, even to data corruption during mass OSD
|
- Versions before 0.8.0 don't have vitastor-disk, so OSDs, initialized by it, won't
|
||||||
restarts. It doesn't mean that you WILL hit this problem if you upgrade without full downtime,
|
start with 0.7.x or 0.6.x. :-)
|
||||||
but it's better to secure yourself against it.
|
|
||||||
|
|
||||||
Also, if you upgrade version from <= 1.7.x to version >= 1.8.0, BUT <= 1.9.0: restart all clients
|
|
||||||
(VMs and so on), otherwise they will hang when monitor clears old PG configuration key,
|
|
||||||
which happens 24 hours after upgrade.
|
|
||||||
|
|
||||||
This is fixed in 1.9.1. So, after upgrading version <= 1.7.x directly to version >= 1.9.1,
|
|
||||||
you DO NOT have to restart all old clients immediately - they will work like before until
|
|
||||||
you decide to upgrade them too. The downside is that you'll have to remove the old PG
|
|
||||||
configuration key (`/vitastor/config/pgs`) from etcd by hand when you make sure that all
|
|
||||||
your clients are restarted.
|
|
||||||
|
|
||||||
### 1.1.x to 1.2.0
|
|
||||||
|
|
||||||
Upgrading version <= 1.1.x to version >= 1.2.0, if you use EC n+k with k>=2, is recommended
|
|
||||||
to be performed with full downtime: first you should stop all clients, then all OSDs,
|
|
||||||
then upgrade and start everything back — because versions before 1.2.0 have several
|
|
||||||
bugs leading to invalid data being read in EC n+k, k>=2 configurations in degraded pools.
|
|
||||||
|
|
||||||
### 0.8.7 to 0.9.0
|
|
||||||
|
|
||||||
Versions <= 0.8.7 are incompatible with versions >= 0.9.0, so you should first
|
|
||||||
upgrade from <= 0.8.7 to 0.8.8 or 0.8.9, and only then to >= 0.9.x. If you upgrade
|
|
||||||
without this intermediate step, client I/O will hang until the end of upgrade process.
|
|
||||||
|
|
||||||
### 0.5.x to 0.6.x
|
|
||||||
|
|
||||||
Upgrading from <= 0.5.x to >= 0.6.x is not supported.
|
|
||||||
|
|
||||||
## Downgrade
|
|
||||||
|
|
||||||
Downgrade are also allowed freely, except the following specific instructions:
|
|
||||||
|
|
||||||
### 1.8.0 to 1.7.1
|
|
||||||
|
|
||||||
Before downgrading from version >= 1.8.0 to version <= 1.7.1
|
|
||||||
you have to copy /vitastor/pg/config etcd key to /vitastor/config/pgs:
|
|
||||||
|
|
||||||
```
|
|
||||||
etcdctl --endpoints=http://... get --print-value-only /vitastor/pg/config | \
|
|
||||||
etcdctl --endpoints=http://... put /vitastor/config/pgs
|
|
||||||
```
|
|
||||||
|
|
||||||
Then you can just install older packages and restart all services.
|
|
||||||
|
|
||||||
If you performed downgrade without first copying that key, run "add all OSDs into the
|
|
||||||
history records of all PGs" from [Restoring from lost pool configuration](#restoring-from-lost-pool-configuration).
|
|
||||||
|
|
||||||
### 1.0.0 to 0.9.x
|
|
||||||
|
|
||||||
Version 1.0.0 has a new disk format, so OSDs initialized on 1.0.0 or later can't
|
|
||||||
be rolled back to 0.9.x or previous versions.
|
|
||||||
|
|
||||||
### 0.8.0 to 0.7.x
|
|
||||||
|
|
||||||
Versions before 0.8.0 don't have vitastor-disk, so OSDs, initialized by it, won't
|
|
||||||
start with older versions (0.4.x - 0.7.x). :-)
|
|
||||||
|
|
||||||
## OSD memory usage
|
## OSD memory usage
|
||||||
|
|
||||||
|
|
|
@ -42,7 +42,7 @@
|
||||||
- **offline** — PG вообще не активирована ни одним OSD. Либо первичный OSD не назначен вообще
|
- **offline** — PG вообще не активирована ни одним OSD. Либо первичный OSD не назначен вообще
|
||||||
(если пул только создан), либо в качестве первичного назначен недоступный OSD, либо
|
(если пул только создан), либо в качестве первичного назначен недоступный OSD, либо
|
||||||
назначенный OSD отказывается запускать эту PG (например, из-за несовпадения block_size),
|
назначенный OSD отказывается запускать эту PG (например, из-за несовпадения block_size),
|
||||||
либо PG остановлена монитором через флаг `pause: true` в `/vitastor/pg/config` в etcd.
|
либо PG остановлена монитором через флаг `pause: true` в `/vitastor/config/pgs` в etcd.
|
||||||
- **starting** — первичный OSD захватил блокировку PG в etcd, PG запускается.
|
- **starting** — первичный OSD захватил блокировку PG в etcd, PG запускается.
|
||||||
- **peering** — первичный OSD опрашивает вторичные OSD на предмет списков объектов данной PG и рассчитывает её состояние.
|
- **peering** — первичный OSD опрашивает вторичные OSD на предмет списков объектов данной PG и рассчитывает её состояние.
|
||||||
- **repeering** — PG ожидает завершения текущих операций ввода-вывода, после чего перейдёт в состояние **peering**.
|
- **repeering** — PG ожидает завершения текущих операций ввода-вывода, после чего перейдёт в состояние **peering**.
|
||||||
|
@ -56,9 +56,9 @@ OSD, на протяжении небольшого периода времен
|
||||||
Состояния **starting**, **repeering**, **stopping** в норме практически не заметны вообще,
|
Состояния **starting**, **repeering**, **stopping** в норме практически не заметны вообще,
|
||||||
PG должны очень быстро переходить из них в другие. Если эти состояния заметны
|
PG должны очень быстро переходить из них в другие. Если эти состояния заметны
|
||||||
хоть сколько-то значительное время — вероятно, какие-то операции на каких-то OSD зависли.
|
хоть сколько-то значительное время — вероятно, какие-то операции на каких-то OSD зависли.
|
||||||
Чтобы найти их, посморите `vitastor-cli status` и поищите слова "slow op" в журналах OSD —
|
Чтобы найти их, ищите "slow op" в журналах OSD — операции, зависшие дольше,
|
||||||
операции, зависшие дольше, чем на [slow_log_interval](../config/osd.ru.md#slow_log_interval),
|
чем на [slow_log_interval](../config/osd.ru.md#slow_log_interval), записываются в
|
||||||
записываются в журналы OSD как "slow op" и отображаются в `status`.
|
журналы OSD как "slow op".
|
||||||
|
|
||||||
Диаграмма переходов:
|
Диаграмма переходов:
|
||||||
|
|
||||||
|
@ -105,16 +105,14 @@ PG должны очень быстро переходить из них в др
|
||||||
## Удаление исправного диска
|
## Удаление исправного диска
|
||||||
|
|
||||||
Перед удалением исправного диска из кластера установите его OSD вес в 0, чтобы убрать с него данные.
|
Перед удалением исправного диска из кластера установите его OSD вес в 0, чтобы убрать с него данные.
|
||||||
Для этого выполните команду `vitastor-cli modify-osd --reweight 0 <НОМЕР_OSD>`.
|
Для этого добавьте в ключ `/vitastor/config/osd/<НОМЕР_OSD>` в etcd значение `"reweight":0`, например:
|
||||||
|
|
||||||
Дождитесь завершения перебалансировки данных, после чего удалите OSD командой `vitastor-disk purge /dev/vitastor/osdN-data`.
|
|
||||||
|
|
||||||
Также вес 0 можно прописать вручную прямо в etcd в ключ `/vitastor/config/osd/<НОМЕР_OSD>`, например:
|
|
||||||
|
|
||||||
```
|
```
|
||||||
etcdctl --endpoints=http://1.1.1.1:2379/v3 put /vitastor/config/osd/1 '{"reweight":0}'
|
etcdctl --endpoints=http://1.1.1.1:2379/v3 put /vitastor/config/osd/1 '{"reweight":0}'
|
||||||
```
|
```
|
||||||
|
|
||||||
|
Дождитесь завершения ребаланса, после чего удалите OSD командой `vitastor-disk purge /dev/vitastor/osdN-data`.
|
||||||
|
|
||||||
## Удаление неисправного диска
|
## Удаление неисправного диска
|
||||||
|
|
||||||
Если диск уже умер, его OSD, скорее всего, уже будет/будут остановлен(ы).
|
Если диск уже умер, его OSD, скорее всего, уже будет/будут остановлен(ы).
|
||||||
|
@ -147,7 +145,7 @@ POOL_ID=1
|
||||||
ALL_OSDS=$(etcdctl --endpoints=your_etcd_address:2379 get --keys-only --prefix /vitastor/osd/stats/ | \
|
ALL_OSDS=$(etcdctl --endpoints=your_etcd_address:2379 get --keys-only --prefix /vitastor/osd/stats/ | \
|
||||||
perl -e '$/ = undef; $a = <>; $a =~ s/\s*$//; $a =~ s!/vitastor/osd/stats/!!g; $a =~ s/\s+/,/g; print $a')
|
perl -e '$/ = undef; $a = <>; $a =~ s/\s*$//; $a =~ s!/vitastor/osd/stats/!!g; $a =~ s/\s+/,/g; print $a')
|
||||||
for i in $(seq 1 $PG_COUNT); do
|
for i in $(seq 1 $PG_COUNT); do
|
||||||
etcdctl --endpoints=your_etcd_address:2379 put /vitastor/pg/history/$POOL_ID/$i '{"all_peers":['$ALL_OSDS']}'
|
etcdctl --endpoints=your_etcd_address:2379 put /vitastor/pg/history/$POOL_ID/$i '{"all_peers":['$ALL_OSDS']}'; done
|
||||||
done
|
done
|
||||||
```
|
```
|
||||||
|
|
||||||
|
@ -166,70 +164,21 @@ done
|
||||||
достаточно обновлять серверы по одному. Однако, конечно, чтобы запущенные виртуальные машины
|
достаточно обновлять серверы по одному. Однако, конечно, чтобы запущенные виртуальные машины
|
||||||
начали использовать новую версию клиентской библиотеки, их тоже нужно перезапустить.
|
начали использовать новую версию клиентской библиотеки, их тоже нужно перезапустить.
|
||||||
|
|
||||||
### 1.7.x -> 1.8.0
|
Исключения (особые указания при обновлении):
|
||||||
|
- Обновляться с версий <= 1.1.x до версий >= 1.2.0, если вы используете EC n+k и k>=2,
|
||||||
|
рекомендуется с временной остановкой кластера — сначала нужно остановить всех клиентов,
|
||||||
|
потом все OSD, потом обновить и запустить всё обратно — из-за нескольких багов, которые
|
||||||
|
могли приводить к некорректному чтению данных в деградированных EC-пулах.
|
||||||
|
- Версии <= 0.8.7 несовместимы с версиями >= 0.9.0, поэтому при обновлении с <= 0.8.7
|
||||||
|
нужно сначала обновиться до 0.8.8 или 0.8.9, а уже потом до любых версий >= 0.9.x.
|
||||||
|
Иначе клиентский ввод-вывод зависнет до завершения обновления.
|
||||||
|
- Обновление с версий 0.5.x и более ранних до 0.6.x и более поздних не поддерживается.
|
||||||
|
|
||||||
Обновляться с версий <= 1.7.x до версий >= 1.8.0 рекомендуется с полной остановкой
|
Откат:
|
||||||
сначала клиентов, а затем кластера, так как в 1.8.0 исправлена проблема (неконсистентность
|
- В версии 1.0.0 поменялся дисковый формат, поэтому OSD, созданные на версии >= 1.0.0,
|
||||||
потоков событий от etcd), способная приводить к появлению incomplete объектов в EC-пулах
|
нельзя откатить до версии 0.9.x и более ранних.
|
||||||
и, хоть и редко, но даже к повреждению данных при массовых перезапусках OSD. Если вы
|
- В версиях ранее 0.8.0 нет vitastor-disk, значит, созданные им OSD нельзя откатить
|
||||||
обновляетесь без полной остановки - это не значит, что вы обязательно столкнётесь с этой
|
до 0.7.x или 0.6.x. :-)
|
||||||
проблемой, но лучше подстраховаться.
|
|
||||||
|
|
||||||
Также, если вы обновляетесь с версии <= 1.7.x до версии >= 1.8.0, НО <= 1.9.0: перезапустите всех
|
|
||||||
клиентов (процессы виртуальных машин можно перезапустить путём миграции на другой сервер),
|
|
||||||
иначе они зависнут, когда монитор удалит старый ключ конфигурации PG, что происходит через
|
|
||||||
24 часа после обновления.
|
|
||||||
|
|
||||||
Однако, это исправлено в 1.9.1. Так что, если вы обновляетесь с <= 1.7.x сразу до >= 1.9.1,
|
|
||||||
вам НЕ нужно сразу перезапускать всех клиентов - они будут работать, как раньше. Минус,
|
|
||||||
правда, в том, что старый ключ конфигурации PG (`/vitastor/config/pgs`) будет нужно удалить
|
|
||||||
вам из etcd вручную - после того, как вы убедитесь, что все клиенты перезапущены.
|
|
||||||
|
|
||||||
### 1.1.x -> 1.2.0
|
|
||||||
|
|
||||||
Обновляться с версий <= 1.1.x до версий >= 1.2.0, если вы используете EC n+k и k>=2,
|
|
||||||
рекомендуется с временной остановкой кластера — сначала нужно остановить всех клиентов,
|
|
||||||
потом все OSD, потом обновить и запустить всё обратно — из-за нескольких багов, которые
|
|
||||||
могли приводить к некорректному чтению данных в деградированных EC-пулах.
|
|
||||||
|
|
||||||
### 0.8.7 -> 0.9.0
|
|
||||||
|
|
||||||
Версии <= 0.8.7 несовместимы с версиями >= 0.9.0, поэтому при обновлении с <= 0.8.7
|
|
||||||
нужно сначала обновиться до 0.8.8 или 0.8.9, а уже потом до любых версий >= 0.9.x.
|
|
||||||
Иначе клиентский ввод-вывод зависнет до завершения обновления.
|
|
||||||
|
|
||||||
### 0.5.x -> 0.6.x
|
|
||||||
|
|
||||||
Обновление с версий 0.5.x и более ранних до 0.6.x и более поздних не поддерживается.
|
|
||||||
|
|
||||||
## Откат версии
|
|
||||||
|
|
||||||
Откат (понижение версии) тоже свободно разрешён, кроме указанных ниже случаев:
|
|
||||||
|
|
||||||
### 1.8.0 -> 1.7.1
|
|
||||||
|
|
||||||
Перед понижением версии с >= 1.8.0 до <= 1.7.1 вы должны скопировать ключ
|
|
||||||
etcd `/vitastor/pg/config` в `/vitastor/config/pgs`:
|
|
||||||
|
|
||||||
```
|
|
||||||
etcdctl --endpoints=http://... get --print-value-only /vitastor/pg/config | \
|
|
||||||
etcdctl --endpoints=http://... put /vitastor/config/pgs
|
|
||||||
```
|
|
||||||
|
|
||||||
После этого можно просто установить более старые пакеты и перезапустить все сервисы.
|
|
||||||
|
|
||||||
Если вы откатили версию, не скопировав предварительно этот ключ - выполните "добавление всех
|
|
||||||
OSD в исторические записи всех PG" из раздела [Восстановление потерянной конфигурации пулов](#восстановление-потерянной-конфигурации-пулов).
|
|
||||||
|
|
||||||
### 1.0.0 -> 0.9.x
|
|
||||||
|
|
||||||
В версии 1.0.0 поменялся дисковый формат, поэтому OSD, созданные на версии >= 1.0.0,
|
|
||||||
нельзя откатить до версии 0.9.x и более ранних.
|
|
||||||
|
|
||||||
### 0.8.0 -> 0.7.x
|
|
||||||
|
|
||||||
В версиях ранее 0.8.0 нет vitastor-disk, значит, созданные им OSD не запустятся на
|
|
||||||
более ранних версиях (0.4.x - 0.7.x). :-)
|
|
||||||
|
|
||||||
## Потребление памяти OSD
|
## Потребление памяти OSD
|
||||||
|
|
||||||
|
|
|
@ -16,7 +16,6 @@ It supports the following commands:
|
||||||
- [create](#create)
|
- [create](#create)
|
||||||
- [snap-create](#create)
|
- [snap-create](#create)
|
||||||
- [modify](#modify)
|
- [modify](#modify)
|
||||||
- [dd](#dd)
|
|
||||||
- [rm](#rm)
|
- [rm](#rm)
|
||||||
- [flatten](#flatten)
|
- [flatten](#flatten)
|
||||||
- [rm-data](#rm-data)
|
- [rm-data](#rm-data)
|
||||||
|
@ -25,10 +24,6 @@ It supports the following commands:
|
||||||
- [fix](#fix)
|
- [fix](#fix)
|
||||||
- [alloc-osd](#alloc-osd)
|
- [alloc-osd](#alloc-osd)
|
||||||
- [rm-osd](#rm-osd)
|
- [rm-osd](#rm-osd)
|
||||||
- [osd-tree](#osd-tree)
|
|
||||||
- [ls-osd](#ls-osd)
|
|
||||||
- [modify-osd](#modify-osd)
|
|
||||||
- [pg-list](#pg-list)
|
|
||||||
- [create-pool](#create-pool)
|
- [create-pool](#create-pool)
|
||||||
- [modify-pool](#modify-pool)
|
- [modify-pool](#modify-pool)
|
||||||
- [ls-pools](#ls-pools)
|
- [ls-pools](#ls-pools)
|
||||||
|
@ -149,60 +144,19 @@ You should resize file system in the image, if present, before shrinking it.
|
||||||
* `-f|--force` - Proceed with shrinking or setting readwrite flag even if the image has children.
|
* `-f|--force` - Proceed with shrinking or setting readwrite flag even if the image has children.
|
||||||
* `--down-ok` - Proceed with shrinking even if some data will be left on unavailable OSDs.
|
* `--down-ok` - Proceed with shrinking even if some data will be left on unavailable OSDs.
|
||||||
|
|
||||||
## dd
|
|
||||||
|
|
||||||
```
|
|
||||||
vitastor-cli dd [iimg=<image> | if=<file>] [oimg=<image> | of=<file>] [bs=1M] \
|
|
||||||
[count=N] [seek/oseek=N] [skip/iseek=M] [iodepth=N] [status=progress] \
|
|
||||||
[conv=nocreat,noerror,nofsync,trunc,nosparse] [iflag=direct] [oflag=direct,append]
|
|
||||||
```
|
|
||||||
|
|
||||||
Copy data between Vitastor images, files and pipes.
|
|
||||||
|
|
||||||
Options can be specified in classic dd style (`key=value`) or like usual (`--key value`).
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|-----------------|-------------------------------------------------------------------------|
|
|
||||||
| `iimg=<image>` | Copy from Vitastor image `<image>` |
|
|
||||||
| `if=<file>` | Copy from file `<file>` |
|
|
||||||
| `oimg=<image>` | Copy to Vitastor image `<image>` |
|
|
||||||
| `of=<file>` | Copy to file `<file>` |
|
|
||||||
| `bs=1M` | Set copy block size |
|
|
||||||
| `count=N` | Copy only N input blocks. If N ends in B it counts bytes, not blocks |
|
|
||||||
| `seek/oseek=N` | Skip N output blocks. If N ends in B it counts bytes, not blocks |
|
|
||||||
| `skip/iseek=N` | Skip N input blocks. If N ends in B it counts bytes, not blocks |
|
|
||||||
| `iodepth=N` | Send N reads or writes in parallel (default 4) |
|
|
||||||
| `status=LEVEL` | The LEVEL of information to print to stderr: none/noxfer/progress |
|
|
||||||
| `size=N` | Specify size for the created output file/image (defaults to input size) |
|
|
||||||
| `iflag=direct` | For input files only: use direct I/O |
|
|
||||||
| `oflag=direct` | For output files only: use direct I/O |
|
|
||||||
| `oflag=append` | For files only: append to output file |
|
|
||||||
| `conv=nocreat` | Do not create output file/image |
|
|
||||||
| `conv=trunc` | Truncate output file/image |
|
|
||||||
| `conv=noerror` | Continue copying after errors |
|
|
||||||
| `conv=nofsync` | Do not call fsync before finishing (default behaviour is fsync) |
|
|
||||||
| `conv=nosparse` | Write all output blocks including all-zero blocks |
|
|
||||||
|
|
||||||
## rm
|
## rm
|
||||||
|
|
||||||
`vitastor-cli rm <from> [<to>] [--writers-stopped] [--down-ok]`
|
`vitastor-cli rm <from> [<to>] [--writers-stopped] [--down-ok]`
|
||||||
|
|
||||||
`vitastor-cli rm (--exact|--matching) <glob> ...`
|
Remove `<from>` or all layers between `<from>` and `<to>` (`<to>` must be a child of `<from>`),
|
||||||
|
rebasing all their children accordingly. --writers-stopped allows merging to be a bit
|
||||||
|
more effective in case of a single 'slim' read-write child and 'fat' removed parent:
|
||||||
|
the child is merged into parent and parent is renamed to child in that case.
|
||||||
|
In other cases parent layers are always merged into children.
|
||||||
|
|
||||||
Remove layer(s) and rebase all their children accordingly.
|
Other options:
|
||||||
|
|
||||||
In the first form, remove `<from>` or layers between `<from>` and its child `<to>`.
|
* `--down-ok` - Continue deletion/merging even if some data will be left on unavailable OSDs.
|
||||||
|
|
||||||
In the second form, remove all images with exact or pattern-matched names.
|
|
||||||
|
|
||||||
Options:
|
|
||||||
|
|
||||||
* `--writers-stopped` allows optimised removal in case of a single 'slim' read-write
|
|
||||||
child and 'fat' removed parent: the child is merged into parent and parent is renamed
|
|
||||||
to child in that case. In other cases parent layers are always merged into children.
|
|
||||||
* `--exact` - remove multiple images with names matching given glob patterns.
|
|
||||||
* `--matching` - remove multiple images with given names
|
|
||||||
* `--down-ok` - continue deletion/merging even if some data will be left on unavailable OSDs.
|
|
||||||
|
|
||||||
## flatten
|
## flatten
|
||||||
|
|
||||||
|
@ -220,7 +174,6 @@ Remove inode data without changing metadata.
|
||||||
--wait-list Retrieve full objects listings before starting to remove objects.
|
--wait-list Retrieve full objects listings before starting to remove objects.
|
||||||
Requires more memory, but allows to show correct removal progress.
|
Requires more memory, but allows to show correct removal progress.
|
||||||
--min-offset Purge only data starting with specified offset.
|
--min-offset Purge only data starting with specified offset.
|
||||||
--max-offset Purge only data before specified offset.
|
|
||||||
```
|
```
|
||||||
|
|
||||||
## merge-data
|
## merge-data
|
||||||
|
@ -293,82 +246,6 @@ Refuses to remove OSDs with data without `--force` and `--allow-data-loss`.
|
||||||
With `--dry-run` only checks if deletion is possible without data loss and
|
With `--dry-run` only checks if deletion is possible without data loss and
|
||||||
redundancy degradation.
|
redundancy degradation.
|
||||||
|
|
||||||
## osd-tree
|
|
||||||
|
|
||||||
`vitastor-cli osd-tree [-l|--long]`
|
|
||||||
|
|
||||||
Show current OSD tree, optionally with I/O statistics if -l is specified.
|
|
||||||
|
|
||||||
Example output:
|
|
||||||
|
|
||||||
```
|
|
||||||
TYPE NAME UP SIZE USED% TAGS WEIGHT BLOCK BITMAP IMM NOOUT
|
|
||||||
host kaveri
|
|
||||||
disk nvme0n1p1
|
|
||||||
osd 3 down 100G 0 % abc,kaveri 1 128k 4k none -
|
|
||||||
osd 4 down 100G 0 % 1 128k 4k none -
|
|
||||||
disk nvme1n1p1
|
|
||||||
osd 5 down 100G 0 % abc,kaveri 1 128k 4k none -
|
|
||||||
osd 6 down 100G 0 % 1 128k 4k none -
|
|
||||||
host stump
|
|
||||||
osd 1 up 100G 37.29 % osdone 1 128k 4k all -
|
|
||||||
osd 2 up 100G 26.8 % abc 1 128k 4k all -
|
|
||||||
osd 7 up 100G 21.84 % 1 128k 4k all -
|
|
||||||
osd 8 up 100G 21.63 % 1 128k 4k all -
|
|
||||||
osd 9 up 100G 20.69 % 1 128k 4k all -
|
|
||||||
osd 10 up 100G 21.61 % 1 128k 4k all -
|
|
||||||
osd 11 up 100G 21.53 % 1 128k 4k all -
|
|
||||||
osd 12 up 100G 22.4 % 1 128k 4k all -
|
|
||||||
```
|
|
||||||
|
|
||||||
## ls-osd
|
|
||||||
|
|
||||||
`vitastor-cli osds|ls-osd|osd-ls [-l|--long]`
|
|
||||||
|
|
||||||
Show current OSDs as list, optionally with I/O statistics if -l is specified.
|
|
||||||
|
|
||||||
Example output:
|
|
||||||
|
|
||||||
```
|
|
||||||
OSD PARENT UP SIZE USED% TAGS WEIGHT BLOCK BITMAP IMM NOOUT
|
|
||||||
3 kaveri/nvme0n1p1 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
4 kaveri/nvme0n1p1 down 100G 0 % 1 128k 4k none -
|
|
||||||
5 kaveri/nvme1n1p1 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
6 kaveri/nvme1n1p1 down 100G 0 % 1 128k 4k none -
|
|
||||||
1 stump up 100G 37.29 % osdone 1 128k 4k all -
|
|
||||||
2 stump up 100G 26.8 % globl 1 128k 4k all -
|
|
||||||
7 stump up 100G 21.84 % 1 128k 4k all -
|
|
||||||
8 stump up 100G 21.63 % 1 128k 4k all -
|
|
||||||
9 stump up 100G 20.69 % 1 128k 4k all -
|
|
||||||
10 stump up 100G 21.61 % 1 128k 4k all -
|
|
||||||
11 stump up 100G 21.53 % 1 128k 4k all -
|
|
||||||
12 stump up 100G 22.4 % 1 128k 4k all -
|
|
||||||
```
|
|
||||||
|
|
||||||
## modify-osd
|
|
||||||
|
|
||||||
`vitastor-cli modify-osd [--tags tag1,tag2,...] [--reweight <number>] [--noout true/false] <osd_number>`
|
|
||||||
|
|
||||||
Set OSD reweight, tags or noout flag. See detail description in [OSD config documentation](../config/pool.en.md#osd-settings).
|
|
||||||
|
|
||||||
## pg-list
|
|
||||||
|
|
||||||
`vitastor-cli pg-list|pg-ls|list-pg|ls-pg|ls-pgs [OPTIONS] [state1+state2] [^state3] [...]`
|
|
||||||
|
|
||||||
List PGs with any of listed state filters (^ or ! in the beginning is negation). Options:
|
|
||||||
|
|
||||||
```
|
|
||||||
--pool <pool name or number> Only list PGs of the given pool.
|
|
||||||
--min <min pg number> Only list PGs with number >= min.
|
|
||||||
--max <max pg number> Only list PGs with number <= max.
|
|
||||||
```
|
|
||||||
|
|
||||||
Examples:
|
|
||||||
|
|
||||||
`vitastor-cli pg-list active+degraded`
|
|
||||||
|
|
||||||
`vitastor-cli pg-list ^active`
|
|
||||||
|
|
||||||
## create-pool
|
## create-pool
|
||||||
|
|
||||||
`vitastor-cli create-pool|pool-create <name> (-s <pg_size>|--ec <N>+<K>) -n <pg_count> [OPTIONS]`
|
`vitastor-cli create-pool|pool-create <name> (-s <pg_size>|--ec <N>+<K>) -n <pg_count> [OPTIONS]`
|
||||||
|
|
|
@ -17,17 +17,12 @@ vitastor-cli - интерфейс командной строки для адм
|
||||||
- [create](#create)
|
- [create](#create)
|
||||||
- [snap-create](#create)
|
- [snap-create](#create)
|
||||||
- [modify](#modify)
|
- [modify](#modify)
|
||||||
- [dd](#dd)
|
|
||||||
- [rm](#rm)
|
- [rm](#rm)
|
||||||
- [flatten](#flatten)
|
- [flatten](#flatten)
|
||||||
- [rm-data](#rm-data)
|
- [rm-data](#rm-data)
|
||||||
- [merge-data](#merge-data)
|
- [merge-data](#merge-data)
|
||||||
- [alloc-osd](#alloc-osd)
|
- [alloc-osd](#alloc-osd)
|
||||||
- [rm-osd](#rm-osd)
|
- [rm-osd](#rm-osd)
|
||||||
- [osd-tree](#osd-tree)
|
|
||||||
- [ls-osd](#ls-osd)
|
|
||||||
- [modify-osd](#modify-osd)
|
|
||||||
- [pg-list](#pg-list)
|
|
||||||
- [create-pool](#create-pool)
|
- [create-pool](#create-pool)
|
||||||
- [modify-pool](#modify-pool)
|
- [modify-pool](#modify-pool)
|
||||||
- [ls-pools](#ls-pools)
|
- [ls-pools](#ls-pools)
|
||||||
|
@ -152,61 +147,23 @@ vitastor-cli snap-create [-p|--pool <id|name>] <image>@<snapshot>
|
||||||
* `-f|--force` - Разрешить уменьшение или перевод в чтение-запись образа, у которого есть клоны.
|
* `-f|--force` - Разрешить уменьшение или перевод в чтение-запись образа, у которого есть клоны.
|
||||||
* `--down-ok` - Разрешить уменьшение, даже если часть данных останется неудалённой на недоступных OSD.
|
* `--down-ok` - Разрешить уменьшение, даже если часть данных останется неудалённой на недоступных OSD.
|
||||||
|
|
||||||
## dd
|
|
||||||
|
|
||||||
```
|
|
||||||
vitastor-cli dd [iimg=<image> | if=<file>] [oimg=<image> | of=<file>] [bs=1M] \
|
|
||||||
[count=N] [seek/oseek=N] [skip/iseek=M] [iodepth=N] [status=progress] \
|
|
||||||
[conv=nocreat,noerror,nofsync,trunc,nosparse] [iflag=direct] [oflag=direct,append]
|
|
||||||
```
|
|
||||||
|
|
||||||
Копировать данные между образами Vitastor, файлами и каналами.
|
|
||||||
|
|
||||||
Опции можно передавать в классическом стиле dd (`key=value`) или как обычно (`--key value`).
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|-----------------|-------------------------------------------------------------------------|
|
|
||||||
| `iimg=<image>` | Копировать из образа Vitastor `<image>` |
|
|
||||||
| `if=<file>` | Копировать из файла `<file>` |
|
|
||||||
| `oimg=<image>` | Копировать в образ Vitastor `<image>` |
|
|
||||||
| `of=<file>` | Копировать в файл `<file>` |
|
|
||||||
| `bs=1M` | Задать размер блока копирования |
|
|
||||||
| `count=N` | Копировать не более N блоков. Если N заканчивается на B - то N байт. |
|
|
||||||
| `seek/oseek=N` | Пропустить N выходных блоков. Если N заканчивается на B - то N байт. |
|
|
||||||
| `skip/iseek=N` | Пропустить N входных блоков. Если N заканчивается на B - то N байт. |
|
|
||||||
| `iodepth=N` | Отправлять N чтений/записей параллельно (по умолчанию 4). |
|
|
||||||
| `status=LEVEL` | Уровень вывода в консоль: none/noxfer/progress |
|
|
||||||
| `size=N` | Задать размер выходного файла/образа (по умолчанию равен размеру входа).|
|
|
||||||
| `iflag=direct` | Только для входного файла: использовать прямой ввод-вывод |
|
|
||||||
| `oflag=direct` | Только для выходного файла: использовать прямой ввод-вывод |
|
|
||||||
| `oflag=append` | Только для файлов: дописывать в конец выходного файла |
|
|
||||||
| `conv=nocreat` | Не создавать выходной файл/образ |
|
|
||||||
| `conv=trunc` | Обрезать выходной файл/образ до размера входа |
|
|
||||||
| `conv=noerror` | Продолжать копирование после ошибок |
|
|
||||||
| `conv=nofsync` | Не вызывать fsync перед завершением |
|
|
||||||
| `conv=nosparse` | Записывать все выходные блоки, включая пустые |
|
|
||||||
|
|
||||||
## rm
|
## rm
|
||||||
|
|
||||||
`vitastor-cli rm <from> [<to>] [--writers-stopped] [--down-ok]`
|
`vitastor-cli rm <from> [<to>] [--writers-stopped] [--down-ok]`
|
||||||
|
|
||||||
`vitastor-cli rm (--exact|--matching) <glob> ...`
|
Удалить образ `<from>` или все слои от `<from>` до `<to>` (`<to>` должен быть дочерним
|
||||||
|
образом `<from>`), одновременно меняя родительские образы их клонов (если таковые есть).
|
||||||
|
|
||||||
Удалить образ(ы), корректно перебазируя их дочерние образы.
|
`--writers-stopped` позволяет чуть более эффективно удалять образы в частом случае, когда
|
||||||
|
у удаляемой цепочки есть только один дочерний образ, содержащий небольшой объём данных.
|
||||||
|
В этом случае дочерний образ вливается в родительский и удаляется, а родительский
|
||||||
|
переименовывается в дочерний.
|
||||||
|
|
||||||
В первой форме удаляет один образ `<from>` или все слои между `<from>` и его дочерним `<to>`.
|
В других случаях родительские слои вливаются в дочерние.
|
||||||
|
|
||||||
Во второй форме, удаляет все образы с точными именами или именами, подходящими под шаблон(ы).
|
Другие опции:
|
||||||
|
|
||||||
Опции:
|
* `--down-ok` - Продолжать удаление/слияние, даже если часть данных останется неудалённой на недоступных OSD.
|
||||||
|
|
||||||
* `--writers-stopped` позволяет чуть более эффективно удалять образы в частом случае, когда
|
|
||||||
у удаляемой цепочки есть только один дочерний образ, содержащий небольшой объём данных.
|
|
||||||
В этом случае дочерний образ вливается в родительский и удаляется, а родительский
|
|
||||||
переименовывается в дочерний.
|
|
||||||
* `--exact` - удалить все образы с именами, подходящими под переданные glob-шаблоны.
|
|
||||||
* `--matching` - удалить все образы с точно заданными именами.
|
|
||||||
* `--down-ok` - продолжать удаление/слияние, даже если часть данных останется неудалённой на недоступных OSD.
|
|
||||||
|
|
||||||
## flatten
|
## flatten
|
||||||
|
|
||||||
|
@ -225,7 +182,6 @@ vitastor-cli dd [iimg=<image> | if=<file>] [oimg=<image> | of=<file>] [bs=1M] \
|
||||||
--wait-list Сначала запросить полный листинг объектов, а потом начать удалять.
|
--wait-list Сначала запросить полный листинг объектов, а потом начать удалять.
|
||||||
Требует больше памяти, но позволяет правильно печатать прогресс удаления.
|
Требует больше памяти, но позволяет правильно печатать прогресс удаления.
|
||||||
--min-offset Удалять только данные, начиная с заданного смещения.
|
--min-offset Удалять только данные, начиная с заданного смещения.
|
||||||
--max-offset Удалять только данные до (исключительно) заданного смещения.
|
|
||||||
```
|
```
|
||||||
|
|
||||||
## merge-data
|
## merge-data
|
||||||
|
@ -307,83 +263,6 @@ vitastor-cli dd [iimg=<image> | if=<file>] [oimg=<image> | of=<file>] [bs=1M] \
|
||||||
С опцией `--dry-run` только проверяет, возможно ли удаление без потери данных и деградации
|
С опцией `--dry-run` только проверяет, возможно ли удаление без потери данных и деградации
|
||||||
избыточности.
|
избыточности.
|
||||||
|
|
||||||
## osd-tree
|
|
||||||
|
|
||||||
`vitastor-cli osd-tree [-l|--long]`
|
|
||||||
|
|
||||||
Показать дерево OSD, со статистикой ввода-вывода, если установлено -l.
|
|
||||||
|
|
||||||
Пример вывода:
|
|
||||||
|
|
||||||
```
|
|
||||||
TYPE NAME UP SIZE USED% TAGS WEIGHT BLOCK BITMAP IMM NOOUT
|
|
||||||
host kaveri
|
|
||||||
disk nvme0n1p1
|
|
||||||
osd 3 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
osd 4 down 100G 0 % 1 128k 4k none -
|
|
||||||
disk nvme1n1p1
|
|
||||||
osd 5 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
osd 6 down 100G 0 % 1 128k 4k none -
|
|
||||||
host stump
|
|
||||||
osd 1 up 100G 37.29 % osdone 1 128k 4k all -
|
|
||||||
osd 2 up 100G 26.8 % globl 1 128k 4k all -
|
|
||||||
osd 7 up 100G 21.84 % 1 128k 4k all -
|
|
||||||
osd 8 up 100G 21.63 % 1 128k 4k all -
|
|
||||||
osd 9 up 100G 20.69 % 1 128k 4k all -
|
|
||||||
osd 10 up 100G 21.61 % 1 128k 4k all -
|
|
||||||
osd 11 up 100G 21.53 % 1 128k 4k all -
|
|
||||||
osd 12 up 100G 22.4 % 1 128k 4k all -
|
|
||||||
```
|
|
||||||
|
|
||||||
## ls-osd
|
|
||||||
|
|
||||||
`vitastor-cli osds|ls-osd|osd-ls [-l|--long]`
|
|
||||||
|
|
||||||
Показать список OSD, со статистикой ввода-вывода, если установлено -l.
|
|
||||||
|
|
||||||
Пример вывода:
|
|
||||||
|
|
||||||
```
|
|
||||||
OSD PARENT UP SIZE USED% TAGS WEIGHT BLOCK BITMAP IMM NOOUT
|
|
||||||
3 kaveri/nvme0n1p1 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
4 kaveri/nvme0n1p1 down 100G 0 % 1 128k 4k none -
|
|
||||||
5 kaveri/nvme1n1p1 down 100G 0 % globl,kaveri 1 128k 4k none -
|
|
||||||
6 kaveri/nvme1n1p1 down 100G 0 % 1 128k 4k none -
|
|
||||||
1 stump up 100G 37.29 % osdone 1 128k 4k all -
|
|
||||||
2 stump up 100G 26.8 % globl 1 128k 4k all -
|
|
||||||
7 stump up 100G 21.84 % 1 128k 4k all -
|
|
||||||
8 stump up 100G 21.63 % 1 128k 4k all -
|
|
||||||
9 stump up 100G 20.69 % 1 128k 4k all -
|
|
||||||
10 stump up 100G 21.61 % 1 128k 4k all -
|
|
||||||
11 stump up 100G 21.53 % 1 128k 4k all -
|
|
||||||
12 stump up 100G 22.4 % 1 128k 4k all -
|
|
||||||
```
|
|
||||||
|
|
||||||
## modify-osd
|
|
||||||
|
|
||||||
`vitastor-cli modify-osd [--tags tag1,tag2,...] [--reweight <number>] [--noout true/false] <osd_number>`
|
|
||||||
|
|
||||||
Установить вес OSD, теги или флаг noout. Смотрите подробное описание в [документации настроек OSD](../config/pool.ru.md#настройки-osd).
|
|
||||||
|
|
||||||
## pg-list
|
|
||||||
|
|
||||||
`vitastor-cli pg-list|pg-ls|list-pg|ls-pg|ls-pgs [OPTIONS] [state1+state2] [^state3] [...]`
|
|
||||||
|
|
||||||
Вывести список PG с состояними, удовлетворяющими любому из переданных фильтров (^ или !
|
|
||||||
в начале фильтра означает отрицание). Опции:
|
|
||||||
|
|
||||||
```
|
|
||||||
--pool <pool name or number> Only list PGs of the given pool.
|
|
||||||
--min <min pg number> Only list PGs with number >= min.
|
|
||||||
--max <max pg number> Only list PGs with number <= max.
|
|
||||||
```
|
|
||||||
|
|
||||||
Примеры:
|
|
||||||
|
|
||||||
`vitastor-cli pg-list active+degraded`
|
|
||||||
|
|
||||||
`vitastor-cli pg-list ^active`
|
|
||||||
|
|
||||||
## create-pool
|
## create-pool
|
||||||
|
|
||||||
`vitastor-cli create-pool|pool-create <name> (-s <pg_size>|--ec <N>+<K>) -n <pg_count> [OPTIONS]`
|
`vitastor-cli create-pool|pool-create <name> (-s <pg_size>|--ec <N>+<K>) -n <pg_count> [OPTIONS]`
|
||||||
|
|
|
@ -13,7 +13,6 @@ It supports the following commands:
|
||||||
- [prepare](#prepare)
|
- [prepare](#prepare)
|
||||||
- [upgrade-simple](#upgrade-simple)
|
- [upgrade-simple](#upgrade-simple)
|
||||||
- [resize](#resize)
|
- [resize](#resize)
|
||||||
- [raw-resize](#raw-resize)
|
|
||||||
- [start/stop/restart/enable/disable](#start/stop/restart/enable/disable)
|
- [start/stop/restart/enable/disable](#start/stop/restart/enable/disable)
|
||||||
- [purge](#purge)
|
- [purge](#purge)
|
||||||
- [read-sb](#read-sb)
|
- [read-sb](#read-sb)
|
||||||
|
@ -51,16 +50,12 @@ Options (automatic mode):
|
||||||
--osd_per_disk <N>
|
--osd_per_disk <N>
|
||||||
Create <N> OSDs on each disk (default 1)
|
Create <N> OSDs on each disk (default 1)
|
||||||
--hybrid
|
--hybrid
|
||||||
Prepare hybrid (HDD+SSD, NVMe+SATA or etc) OSDs using provided devices. By default,
|
Prepare hybrid (HDD+SSD) OSDs using provided devices. SSDs will be used for
|
||||||
any passed SSDs will be used for journals and metadata, HDDs will be used for data,
|
journals and metadata, HDDs will be used for data. Partitions for journals and
|
||||||
but you can override this behaviour with --fast-devices option. Journal and metadata
|
metadata will be created automatically. Whether disks are SSD or HDD is decided
|
||||||
partitions will be created automatically. In the default mode, SSD and HDD disks
|
by the `/sys/block/.../queue/rotational` flag. In hybrid mode, default object
|
||||||
are distinguished by the `/sys/block/.../queue/rotational` flag. When HDDs are used
|
size is 1 MB instead of 128 KB, default journal size is 1 GB instead of 32 MB,
|
||||||
for data in hybrid mode, default block_size is 1 MB instead of 128 KB, default journal
|
and throttle_small_writes is enabled by default.
|
||||||
size is 1 GB instead of 32 MB, and throttle_small_writes is enabled by default.
|
|
||||||
--fast-devices /dev/nvmeX,/dev/nvmeY
|
|
||||||
In --hybrid mode, use these devices for journal and metadata instead of auto-detecting
|
|
||||||
and extracting them from the main [devices...] list.
|
|
||||||
--disable_data_fsync auto
|
--disable_data_fsync auto
|
||||||
Disable data device cache and fsync (1/yes/true = on, default auto)
|
Disable data device cache and fsync (1/yes/true = on, default auto)
|
||||||
--disable_meta_fsync auto
|
--disable_meta_fsync auto
|
||||||
|
@ -132,49 +127,25 @@ Requires the `sfdisk` utility.
|
||||||
|
|
||||||
## resize
|
## resize
|
||||||
|
|
||||||
`vitastor-disk resize <osd_num>|<osd_device> [OPTIONS]`
|
`vitastor-disk resize <ALL_OSD_PARAMETERS> <NEW_LAYOUT> [--iodepth 32]`
|
||||||
|
|
||||||
Resize data area and/or move journal and metadata:
|
Resize data area and/or rewrite/move journal and metadata.
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|---------------------------|----------------------------------------|
|
|
||||||
| `--move-journal TARGET` | move journal to `TARGET` |
|
|
||||||
| `--move-meta TARGET` | move metadata to `TARGET` |
|
|
||||||
| `--journal-size NEW_SIZE` | resize journal to `NEW_SIZE` |
|
|
||||||
| `--data-size NEW_SIZE` | resize data device to `NEW_SIZE` |
|
|
||||||
| `--dry-run` | only show new layout, do not apply it |
|
|
||||||
|
|
||||||
`NEW_SIZE` may include k/m/g/t suffixes.
|
|
||||||
|
|
||||||
`TARGET` may be one of:
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|----------------|--------------------------------------------------------------------------|
|
|
||||||
| `<partition>` | move journal/metadata to an existing GPT partition |
|
|
||||||
| `<raw_device>` | create a GPT partition on `<raw_device>` and move journal/metadata to it |
|
|
||||||
| `""` | (empty string) move journal/metadata back to the data device |
|
|
||||||
|
|
||||||
## raw-resize
|
|
||||||
|
|
||||||
`vitastor-disk raw-resize <ALL_OSD_PARAMETERS> <NEW_LAYOUT> [--iodepth 32]`
|
|
||||||
|
|
||||||
Resize data area and/or rewrite/move journal and metadata (manual format).
|
|
||||||
|
|
||||||
`ALL_OSD_PARAMETERS` must include all (at least all disk-related)
|
`ALL_OSD_PARAMETERS` must include all (at least all disk-related)
|
||||||
parameters from OSD command line (i.e. from systemd unit or superblock).
|
parameters from OSD command line (i.e. from systemd unit or superblock).
|
||||||
|
|
||||||
`NEW_LAYOUT` may include new disk layout parameters:
|
`NEW_LAYOUT` may include new disk layout parameters:
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
```
|
||||||
|-----------------------------|-------------------------------------------|
|
--new_data_offset SIZE resize data area so it starts at SIZE
|
||||||
| `--new_data_offset SIZE` | resize data area so it starts at `SIZE` |
|
--new_data_len SIZE resize data area to SIZE bytes
|
||||||
| `--new_data_len SIZE` | resize data area to `SIZE` bytes |
|
--new_meta_device PATH use PATH for new metadata
|
||||||
| `--new_meta_device PATH` | use `PATH` for new metadata |
|
--new_meta_offset SIZE make new metadata area start at SIZE
|
||||||
| `--new_meta_offset SIZE` | make new metadata area start at `SIZE` |
|
--new_meta_len SIZE make new metadata area SIZE bytes long
|
||||||
| `--new_meta_len SIZE` | make new metadata area `SIZE` bytes long |
|
--new_journal_device PATH use PATH for new journal
|
||||||
| `--new_journal_device PATH` | use `PATH` for new journal |
|
--new_journal_offset SIZE make new journal area start at SIZE
|
||||||
| `--new_journal_offset SIZE` | make new journal area start at `SIZE` |
|
--new_journal_len SIZE make new journal area SIZE bytes long
|
||||||
| `--new_journal_len SIZE` | make new journal area `SIZE` bytes long |
|
```
|
||||||
|
|
||||||
SIZE may include k/m/g/t suffixes. If any of the new layout parameter
|
SIZE may include k/m/g/t suffixes. If any of the new layout parameter
|
||||||
options are not specified, old values will be used.
|
options are not specified, old values will be used.
|
||||||
|
@ -246,14 +217,10 @@ Intended for use from startup scripts (i.e. from systemd units).
|
||||||
|
|
||||||
## dump-journal
|
## dump-journal
|
||||||
|
|
||||||
`vitastor-disk dump-journal [OPTIONS] <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk dump-journal [OPTIONS] <journal_file> <journal_block_size> <offset> <size>`
|
`vitastor-disk dump-journal [OPTIONS] <journal_file> <journal_block_size> <offset> <size>`
|
||||||
|
|
||||||
Dump journal in human-readable or JSON (if `--json` is specified) format.
|
Dump journal in human-readable or JSON (if `--json` is specified) format.
|
||||||
|
|
||||||
You can specify any OSD device (data, metadata or journal), or the layout manually.
|
|
||||||
|
|
||||||
Options:
|
Options:
|
||||||
|
|
||||||
```
|
```
|
||||||
|
@ -266,35 +233,23 @@ Options:
|
||||||
|
|
||||||
## write-journal
|
## write-journal
|
||||||
|
|
||||||
`vitastor-disk write-journal <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk write-journal <journal_file> <journal_block_size> <bitmap_size> <offset> <size>`
|
`vitastor-disk write-journal <journal_file> <journal_block_size> <bitmap_size> <offset> <size>`
|
||||||
|
|
||||||
Write journal from JSON taken from standard input in the same format as produced by
|
Write journal from JSON taken from standard input in the same format as produced by
|
||||||
`dump-journal --json --format data`.
|
`dump-journal --json --format data`.
|
||||||
|
|
||||||
You can specify any OSD device (data, metadata or journal), or the layout manually.
|
|
||||||
|
|
||||||
## dump-meta
|
## dump-meta
|
||||||
|
|
||||||
`vitastor-disk dump-meta <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk dump-meta <meta_file> <meta_block_size> <offset> <size>`
|
`vitastor-disk dump-meta <meta_file> <meta_block_size> <offset> <size>`
|
||||||
|
|
||||||
Dump metadata in JSON format.
|
Dump metadata in JSON format.
|
||||||
|
|
||||||
You can specify any OSD device (data, metadata or journal), or the layout manually.
|
|
||||||
|
|
||||||
## write-meta
|
## write-meta
|
||||||
|
|
||||||
`vitastor-disk write-meta <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk write-meta <meta_file> <offset> <size>`
|
`vitastor-disk write-meta <meta_file> <offset> <size>`
|
||||||
|
|
||||||
Write metadata from JSON taken from standard input in the same format as produced by `dump-meta`.
|
Write metadata from JSON taken from standard input in the same format as produced by `dump-meta`.
|
||||||
|
|
||||||
You can specify any OSD device (data, metadata or journal), or the layout manually.
|
|
||||||
|
|
||||||
## simple-offsets
|
## simple-offsets
|
||||||
|
|
||||||
`vitastor-disk simple-offsets <device>`
|
`vitastor-disk simple-offsets <device>`
|
||||||
|
|
|
@ -13,7 +13,6 @@ vitastor-disk - инструмент командной строки для уп
|
||||||
- [prepare](#prepare)
|
- [prepare](#prepare)
|
||||||
- [upgrade-simple](#upgrade-simple)
|
- [upgrade-simple](#upgrade-simple)
|
||||||
- [resize](#resize)
|
- [resize](#resize)
|
||||||
- [raw-resize](#raw-resize)
|
|
||||||
- [start/stop/restart/enable/disable](#start/stop/restart/enable/disable)
|
- [start/stop/restart/enable/disable](#start/stop/restart/enable/disable)
|
||||||
- [purge](#purge)
|
- [purge](#purge)
|
||||||
- [read-sb](#read-sb)
|
- [read-sb](#read-sb)
|
||||||
|
@ -51,17 +50,12 @@ vitastor-disk - инструмент командной строки для уп
|
||||||
--osd_per_disk <N>
|
--osd_per_disk <N>
|
||||||
Создавать по несколько (<N>) OSD на каждом диске (по умолчанию 1)
|
Создавать по несколько (<N>) OSD на каждом диске (по умолчанию 1)
|
||||||
--hybrid
|
--hybrid
|
||||||
Инициализировать гибридные (HDD+SSD, NVMe+SATA и т.п.) OSD на указанных дисках.
|
Инициализировать гибридные (HDD+SSD) OSD на указанных дисках. SSD будут
|
||||||
По умолчанию, SSD будут использованы для журналов и метаданных, а HDD - для данных,
|
использованы для журналов и метаданных, а HDD - для данных. Разделы для журналов
|
||||||
но вы можете поменять это поведение опцией --fast-devices. Разделы для журналов
|
и метаданных будут созданы автоматически. Является ли диск SSD или HDD, определяется
|
||||||
и метаданных будут созданы автоматически. В режиме по умолчанию SSD и HDD-диски
|
по флагу `/sys/block/.../queue/rotational`. В гибридном режиме по умолчанию
|
||||||
различаются по флагу `/sys/block/.../queue/rotational`. Когда в гибридном режиме
|
используется размер объекта 1 МБ вместо 128 КБ, размер журнала 1 ГБ вместо 32 МБ
|
||||||
для данных используются HDD, по умолчанию размер блока устанавливается 1 МБ вместо
|
и включённый throttle_small_writes.
|
||||||
128 КБ, размер журнала 1 ГБ вместо 32 МБ, и throttle_small_writes включается по
|
|
||||||
умолчанию.
|
|
||||||
--fast-devices /dev/nvmeX,/dev/nvmeY
|
|
||||||
Использовать данные диски для журналов и метаданных в гибридном режиме вместо их
|
|
||||||
автоопределения и извлечения из основного списка [devices...].
|
|
||||||
--disable_data_fsync auto
|
--disable_data_fsync auto
|
||||||
Отключать кэш и fsync-и для устройств данных. (1/yes/true = да, по умолчанию автоопределение)
|
Отключать кэш и fsync-и для устройств данных. (1/yes/true = да, по умолчанию автоопределение)
|
||||||
--disable_meta_fsync auto
|
--disable_meta_fsync auto
|
||||||
|
@ -135,51 +129,27 @@ throttle_target_mbs, throttle_target_parallelism, throttle_threshold_us.
|
||||||
|
|
||||||
## resize
|
## resize
|
||||||
|
|
||||||
`vitastor-disk resize <osd_num>|<osd_device> [OPTIONS]`
|
`vitastor-disk resize <ALL_OSD_PARAMETERS> <NEW_LAYOUT> [--iodepth 32]`
|
||||||
|
|
||||||
Изменить размер области данных и/или переместить журнал и метаданные:
|
Изменить размер области данных и/или переместить журнал и метаданные.
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
В `ALL_OSD_PARAMETERS` нужно указать все относящиеся к диску параметры OSD
|
||||||
|-------------------------------|------------------------------------------------|
|
|
||||||
| `--move-journal ЦЕЛЬ` | переместить журнал на `ЦЕЛЬ` |
|
|
||||||
| `--move-meta ЦЕЛЬ` | переместить метаданные на `ЦЕЛЬ` |
|
|
||||||
| `--journal-size НОВЫЙ_РАЗМЕР` | изменить размер журнала на `НОВЫЙ_РАЗМЕР` |
|
|
||||||
| `--data-size НОВЫЙ_РАЗМЕР` | изменить размер диска данных на `НОВЫЙ_РАЗМЕР` |
|
|
||||||
| `--dry-run` | показать новые параметры, но не применять их |
|
|
||||||
|
|
||||||
`НОВЫЙ_РАЗМЕР` может быть указан с суффиксами k/m/g/t (кило/мега/гига/терабайт).
|
|
||||||
|
|
||||||
`ЦЕЛЬ` может быть одним из:
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|-----------------|-------------------------------------------------------------------------------------|
|
|
||||||
| `<раздел>` | переместить журнал/метаданные на существующий GPT-раздел |
|
|
||||||
| `<полный_диск>` | создать GPT-раздел на диске `<полный_диск>` и переместить журнал/метаданные на него |
|
|
||||||
| `""` | (пустая строка) переместить журнал/метаданные обратно на диск данных |
|
|
||||||
|
|
||||||
## raw-resize
|
|
||||||
|
|
||||||
`vitastor-disk raw-resize <ВСЕ_ПАРАМЕТРЫ_OSD> <НОВЫЕ_РАЗМЕРЫ> [--iodepth 32]`
|
|
||||||
|
|
||||||
Изменить размер области данных и/или переместить журнал и метаданные (ручной формат).
|
|
||||||
|
|
||||||
В `ВСЕ_ПАРАМЕТРЫ_OSD` нужно указать все относящиеся к диску параметры OSD
|
|
||||||
из суперблока OSD или из файла сервиса systemd (в старых версиях).
|
из суперблока OSD или из файла сервиса systemd (в старых версиях).
|
||||||
|
|
||||||
В `НОВЫЕ_РАЗМЕРЫ` нужно указать новые параметры расположения данных:
|
В `NEW_LAYOUT` нужно указать новые параметры расположения данных:
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
```
|
||||||
|-------------------------------|-------------------------------------------------------|
|
--new_data_offset РАЗМЕР сдвинуть начало области данных на РАЗМЕР байт
|
||||||
| `--new_data_offset РАЗМЕР` | сдвинуть начало области данных на `РАЗМЕР` байт |
|
--new_data_len РАЗМЕР изменить размер области данных до РАЗМЕР байт
|
||||||
| `--new_data_len РАЗМЕР` | изменить размер области данных до `РАЗМЕР` байт |
|
--new_meta_device ПУТЬ использовать ПУТЬ как новое устройство метаданных
|
||||||
| `--new_meta_device ПУТЬ` | использовать `ПУТЬ` как новое устройство метаданных |
|
--new_meta_offset РАЗМЕР разместить новые метаданные по смещению РАЗМЕР байт
|
||||||
| `--new_meta_offset РАЗМЕР` | разместить новые метаданные по смещению `РАЗМЕР` байт |
|
--new_meta_len РАЗМЕР сделать новые метаданные размером РАЗМЕР байт
|
||||||
| `--new_meta_len РАЗМЕР` | сделать новые метаданные размером `РАЗМЕР` байт |
|
--new_journal_device ПУТЬ использовать ПУТЬ как новое устройство журнала
|
||||||
| `--new_journal_device ПУТЬ` | использовать `ПУТЬ` как новое устройство журнала |
|
--new_journal_offset РАЗМЕР разместить новый журнал по смещению РАЗМЕР байт
|
||||||
| `--new_journal_offset РАЗМЕР` | разместить новый журнал по смещению `РАЗМЕР` байт |
|
--new_journal_len РАЗМЕР сделать новый журнал размером РАЗМЕР байт
|
||||||
| `--new_journal_len РАЗМЕР` | сделать новый журнал размером `РАЗМЕР` байт |
|
```
|
||||||
|
|
||||||
`РАЗМЕР` может быть указан с суффиксами k/m/g/t. Если любой из новых параметров
|
РАЗМЕР может быть указан с суффиксами k/m/g/t. Если любой из новых параметров
|
||||||
расположения не указан, он принимается равным старому значению.
|
расположения не указан, он принимается равным старому значению.
|
||||||
|
|
||||||
## start/stop/restart/enable/disable
|
## start/stop/restart/enable/disable
|
||||||
|
@ -254,15 +224,10 @@ OSD отключены fsync-и.
|
||||||
|
|
||||||
## dump-journal
|
## dump-journal
|
||||||
|
|
||||||
`vitastor-disk dump-journal <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk dump-journal [OPTIONS] <journal_file> <journal_block_size> <offset> <size>`
|
`vitastor-disk dump-journal [OPTIONS] <journal_file> <journal_block_size> <offset> <size>`
|
||||||
|
|
||||||
Вывести журнал в человекочитаемом или в JSON (с опцией `--json`) виде.
|
Вывести журнал в человекочитаемом или в JSON (с опцией `--json`) виде.
|
||||||
|
|
||||||
Вы можете указать любой раздел OSD - данных, журнала или метаданных - либо указать все
|
|
||||||
параметры расположения вручную.
|
|
||||||
|
|
||||||
Опции:
|
Опции:
|
||||||
|
|
||||||
```
|
```
|
||||||
|
@ -275,37 +240,22 @@ OSD отключены fsync-и.
|
||||||
|
|
||||||
## write-journal
|
## write-journal
|
||||||
|
|
||||||
`vitastor-disk write-journal <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk write-journal <journal_file> <journal_block_size> <bitmap_size> <offset> <size>`
|
`vitastor-disk write-journal <journal_file> <journal_block_size> <bitmap_size> <offset> <size>`
|
||||||
|
|
||||||
Записать журнал из JSON со стандартного ввода в формате, аналогичном `dump-journal --json --format data`.
|
Записать журнал из JSON со стандартного ввода в формате, аналогичном `dump-journal --json --format data`.
|
||||||
|
|
||||||
Вы можете указать любой раздел OSD - данных, журнала или метаданных - либо указать все
|
|
||||||
параметры расположения вручную.
|
|
||||||
|
|
||||||
## dump-meta
|
## dump-meta
|
||||||
|
|
||||||
`vitastor-disk dump-meta <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk dump-meta <meta_file> <meta_block_size> <offset> <size>`
|
`vitastor-disk dump-meta <meta_file> <meta_block_size> <offset> <size>`
|
||||||
|
|
||||||
Вывести метаданные в формате JSON.
|
Вывести метаданные в формате JSON.
|
||||||
|
|
||||||
Вы можете указать любой раздел OSD - данных, журнала или метаданных - либо указать все
|
|
||||||
параметры расположения вручную.
|
|
||||||
|
|
||||||
## write-meta
|
## write-meta
|
||||||
|
|
||||||
`vitastor-disk write-meta <osd_device>`
|
|
||||||
|
|
||||||
`vitastor-disk write-meta <meta_file> <offset> <size>`
|
`vitastor-disk write-meta <meta_file> <offset> <size>`
|
||||||
|
|
||||||
Записать метаданные из JSON со стандартного ввода в формате, аналогичном `dump-meta`.
|
Записать метаданные из JSON со стандартного ввода в формате, аналогичном `dump-meta`.
|
||||||
|
|
||||||
Вы можете указать любой раздел OSD - данных, журнала или метаданных - либо указать все
|
|
||||||
параметры расположения вручную.
|
|
||||||
|
|
||||||
## simple-offsets
|
## simple-offsets
|
||||||
|
|
||||||
`vitastor-disk simple-offsets <device>`
|
`vitastor-disk simple-offsets <device>`
|
||||||
|
|
|
@ -96,7 +96,7 @@ Example output (JSON format):
|
||||||
vitastor-nbd netlink-map [/dev/nbdN] (--image <image> | --pool <pool> --inode <inode> --size <size in bytes>)
|
vitastor-nbd netlink-map [/dev/nbdN] (--image <image> | --pool <pool> --inode <inode> --size <size in bytes>)
|
||||||
```
|
```
|
||||||
|
|
||||||
On recent kernel versions it's also possible to map NBD devices using netlink interface.
|
On recent kernel versions it's also possinle to map NBD devices using netlink interface.
|
||||||
|
|
||||||
This is an experimental feature because it doesn't solve all issues of NBD. Differences from regular ioctl-based 'map':
|
This is an experimental feature because it doesn't solve all issues of NBD. Differences from regular ioctl-based 'map':
|
||||||
|
|
||||||
|
|
|
@ -11,8 +11,6 @@ Vitastor has two file system implementations. Both can be used via `vitastor-nfs
|
||||||
Commands:
|
Commands:
|
||||||
- [mount](#mount)
|
- [mount](#mount)
|
||||||
- [start](#start)
|
- [start](#start)
|
||||||
- [upgrade](#upgrade)
|
|
||||||
- [defrag](#defrag)
|
|
||||||
|
|
||||||
## Pseudo-FS
|
## Pseudo-FS
|
||||||
|
|
||||||
|
@ -88,6 +86,10 @@ POSIX features currently not implemented in VitastorFS:
|
||||||
- Modification time (`mtime`) is updated lazily every second (like `-o lazytime`)
|
- Modification time (`mtime`) is updated lazily every second (like `-o lazytime`)
|
||||||
|
|
||||||
Other notable missing features which should be addressed in the future:
|
Other notable missing features which should be addressed in the future:
|
||||||
|
- Defragmentation of "shared" inodes. Files smaller than pool object size (block_size
|
||||||
|
multiplied by data part count if pool is EC) are internally stored in large block
|
||||||
|
volumes sequentially, one after another, and leave garbage after deleting or resizing.
|
||||||
|
Defragmentator will be implemented to collect this garbage.
|
||||||
- Inode ID reuse. Currently inode IDs always grow, the limit is 2^48 inodes, so
|
- Inode ID reuse. Currently inode IDs always grow, the limit is 2^48 inodes, so
|
||||||
in theory you may hit it if you create and delete a very large number of files
|
in theory you may hit it if you create and delete a very large number of files
|
||||||
- Compaction of the key-value B-Tree. Current implementation never merges or deletes
|
- Compaction of the key-value B-Tree. Current implementation never merges or deletes
|
||||||
|
@ -111,21 +113,6 @@ settings, because Vitastor NFS proxy doesn't keep uncommitted data in memory
|
||||||
with these settings. But it may even work without `immediate_commit=all` because
|
with these settings. But it may even work without `immediate_commit=all` because
|
||||||
the Linux NFS client repeats all uncommitted writes if it loses the connection.
|
the Linux NFS client repeats all uncommitted writes if it loses the connection.
|
||||||
|
|
||||||
## RDMA
|
|
||||||
|
|
||||||
vitastor-nfs supports NFS over RDMA, which, in theory, should also allow to use
|
|
||||||
VitastorFS from GPUDirect.
|
|
||||||
|
|
||||||
You can test NFS-RDMA even if you don't have an RDMA NIC using SoftROCE:
|
|
||||||
|
|
||||||
1. First, add SoftROCE device on both servers: `rdma link add rxe0 type rxe netdev eth0`.
|
|
||||||
Here, `rdma` utility is a part the iproute2 package, and `eth0` should be replaced with
|
|
||||||
the name of your Ethernet NIC.
|
|
||||||
|
|
||||||
2. Start vitastor-nfs with RDMA: `vitastor-nfs start (--fs <NAME> | --block) --pool <POOL> --port 20049 --nfs_rdma 20049 --portmap 0`
|
|
||||||
|
|
||||||
3. Mount the FS: `mount 192.168.0.10:/mnt/test/ /mnt/vita/ -o port=20049,mountport=20049,nfsvers=3,soft,nolock,rdma`
|
|
||||||
|
|
||||||
## Commands
|
## Commands
|
||||||
|
|
||||||
### mount
|
### mount
|
||||||
|
@ -147,46 +134,10 @@ The server will be automatically stopped when the FS is unmounted.
|
||||||
Start network NFS server. Options:
|
Start network NFS server. Options:
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
| <!-- --> | <!-- --> |
|
||||||
|------------------------|-----------------------------------------------------------------------------------------------------------------------------|
|
|-----------------|------------------------------------------------------------|
|
||||||
| `--bind <IP>` | bind service to \<IP> address (default 0.0.0.0) |
|
| `--bind <IP>` | bind service to \<IP> address (default 0.0.0.0) |
|
||||||
| `--port <PORT>` | use port \<PORT> for NFS services (default is 2049). Specify "auto" to auto-select and print port |
|
| `--port <PORT>` | use port \<PORT> for NFS services (default is 2049) |
|
||||||
| `--portmap 0` | do not listen on port 111 (portmap/rpcbind, requires root) |
|
| `--portmap 0` | do not listen on port 111 (portmap/rpcbind, requires root) |
|
||||||
| `--nfs_rdma <PORT>` | enable NFS-RDMA at RDMA-CM port \<PORT> (you can try 20049). If RDMA is enabled and --port is set to 0, TCP will be disabled |
|
|
||||||
| `--nfs_rdma_credit 16` | maximum operation credit for RDMA clients (max iodepth) |
|
|
||||||
| `--nfs_rdma_send 1024` | maximum RDMA send operation count (should be larger than iodepth) |
|
|
||||||
| `--nfs_rdma_alloc 1M` | RDMA memory allocation rounding |
|
|
||||||
| `--nfs_rdma_gc 64M` | maximum unused RDMA buffers |
|
|
||||||
|
|
||||||
### upgrade
|
|
||||||
|
|
||||||
`vitastor-nfs --fs <NAME> upgrade`
|
|
||||||
|
|
||||||
Upgrade FS metadata. Can be run online, but server(s) should be restarted after upgrade.
|
|
||||||
|
|
||||||
### defrag
|
|
||||||
|
|
||||||
`vitastor-nfs --fs <NAME> defrag [OPTIONS] [--dry-run]`
|
|
||||||
|
|
||||||
Defragment volumes used for small file storage having more than \<defrag_percent> %
|
|
||||||
of data removed. Can be run online.
|
|
||||||
|
|
||||||
In VitastorFS, small files are stored in large "volumes" / "shared inodes" one
|
|
||||||
after another. When you delete or extend such files, they are moved and garbage is left
|
|
||||||
behind. Defragmentation removes garbage and moves data still in use to new volumes.
|
|
||||||
|
|
||||||
Options:
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|----------------------------|------------------------------------------------------------------------ |
|
|
||||||
| `--volume_untouched 86400` | Defragment volumes last appended to at least this number of seconds ago |
|
|
||||||
| `--defrag_percent 50` | Defragment volumes with at least this % of removed data |
|
|
||||||
| `--defrag_block_count 16` | Read this number of pool blocks at once during defrag |
|
|
||||||
| `--defrag_iodepth 16` | Move up to this number of files in parallel during defrag |
|
|
||||||
| `--trace` | Print verbose defragmentation status |
|
|
||||||
| `--dry-run` | Skip modifications, only print status |
|
|
||||||
| `--recalc-stats` | Recalculate all volume statistics |
|
|
||||||
| `--include-empty` | Include old and empty volumes; make sure to restart NFS servers before using it |
|
|
||||||
| `--no-rm` | Move, but do not delete data |
|
|
||||||
|
|
||||||
## Common options
|
## Common options
|
||||||
|
|
||||||
|
|
|
@ -11,8 +11,6 @@
|
||||||
Команды:
|
Команды:
|
||||||
- [mount](#mount)
|
- [mount](#mount)
|
||||||
- [start](#start)
|
- [start](#start)
|
||||||
- [upgrade](#upgrade)
|
|
||||||
- [defrag](#defrag)
|
|
||||||
|
|
||||||
## Псевдо-ФС
|
## Псевдо-ФС
|
||||||
|
|
||||||
|
@ -90,6 +88,11 @@ JSON-формате :-). Для инспекции содержимого БД
|
||||||
- Времена модификации (`mtime`) отслеживаются асинхронно (как будто ФС смонтирована с `-o lazytime`)
|
- Времена модификации (`mtime`) отслеживаются асинхронно (как будто ФС смонтирована с `-o lazytime`)
|
||||||
|
|
||||||
Другие недостающие функции, которые нужно добавить в будущем:
|
Другие недостающие функции, которые нужно добавить в будущем:
|
||||||
|
- Дефрагментация "общих инодов". На уровне реализации ФС файлы, меньшие, чем размер
|
||||||
|
объекта пула (block_size умножить на число частей данных, если пул EC),
|
||||||
|
упаковываются друг за другом в большие "общие" иноды/тома. Если такие файлы удалять
|
||||||
|
или увеличивать, они перемещаются и оставляют за собой "мусор", вот тут-то и нужен
|
||||||
|
дефрагментатор.
|
||||||
- Переиспользование номеров инодов. В текущей реализации номера инодов всё время
|
- Переиспользование номеров инодов. В текущей реализации номера инодов всё время
|
||||||
увеличиваются, так что в теории вы можете упереться в лимит, если насоздаёте
|
увеличиваются, так что в теории вы можете упереться в лимит, если насоздаёте
|
||||||
и наудаляете больше, чем 2^48 файлов.
|
и наудаляете больше, чем 2^48 файлов.
|
||||||
|
@ -116,21 +119,6 @@ JSON-формате :-). Для инспекции содержимого БД
|
||||||
даже без `immediate_commit=all`, потому что NFS-клиент ядра Linux повторяет все
|
даже без `immediate_commit=all`, потому что NFS-клиент ядра Linux повторяет все
|
||||||
незафиксированные запросы при потере соединения.
|
незафиксированные запросы при потере соединения.
|
||||||
|
|
||||||
## RDMA
|
|
||||||
|
|
||||||
vitastor-nfs поддерживает NFS через RDMA. В теории это также должно позволять использовать
|
|
||||||
VitastorFS из GPUDirect.
|
|
||||||
|
|
||||||
Вы можете протестировать NFS-RDMA, даже если у вас нет RDMA-карты, с помощью SoftROCE:
|
|
||||||
|
|
||||||
1. Сначала создайте SoftROCE устройства на обоих тестовых серверах: `rdma link add rxe0 type rxe netdev eth0`.
|
|
||||||
Утилита `rdma` входит в состав пакета iproute2, а `eth0` вам нужно заменить на имя своей
|
|
||||||
сетевой карты.
|
|
||||||
|
|
||||||
2. Запустите vitastor-nfs с RDMA: `vitastor-nfs start (--fs <NAME> | --block) --pool <POOL> --port 20049 --nfs_rdma 20049 --portmap 0`
|
|
||||||
|
|
||||||
3. Смонтируйте ФС: `mount 192.168.0.10:/mnt/test/ /mnt/vita/ -o port=20049,mountport=20049,nfsvers=3,soft,nolock,rdma`
|
|
||||||
|
|
||||||
## Команды
|
## Команды
|
||||||
|
|
||||||
### mount
|
### mount
|
||||||
|
@ -152,49 +140,10 @@ VitastorFS из GPUDirect.
|
||||||
Запустить сетевой NFS-сервер. Опции:
|
Запустить сетевой NFS-сервер. Опции:
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
| <!-- --> | <!-- --> |
|
||||||
|------------------------|-----------------------------------------------------------------------------------------------------------------------------|
|
|-----------------|-----------------------------------------------------------------------|
|
||||||
| `--bind <IP>` | принимать соединения по адресу \<IP> (по умолчанию 0.0.0.0 - на всех) |
|
| `--bind <IP>` | принимать соединения по адресу \<IP> (по умолчанию 0.0.0.0 - на всех) |
|
||||||
| `--port <PORT>` | использовать порт \<PORT> для NFS-сервисов (по умолчанию 2049). Укажите "auto", чтобы выбрать и напечатать случайный порт |
|
| `--port <PORT>` | использовать порт \<PORT> для NFS-сервисов (по умолчанию 2049) |
|
||||||
| `--portmap 0` | отключить сервис portmap/rpcbind на порту 111 (по умолчанию включён и требует root привилегий) |
|
| `--portmap 0` | отключить сервис portmap/rpcbind на порту 111 (по умолчанию включён и требует root привилегий) |
|
||||||
| `--nfs_rdma <PORT>` | включить NFS-RDMA на порту RDMA-CM \<PORT> (попробуйте 20049). Если RDMA включено и указано `--port 0`, TCP будет отключено |
|
|
||||||
| `--nfs_rdma_credit 16` | максимальный "кредит", глубина очереди для NFS-клиентов |
|
|
||||||
| `--nfs_rdma_send 1024` | максимальное число операций RDMA отправки (должно быть больше nfs_rdma_credit) |
|
|
||||||
| `--nfs_rdma_alloc 1M` | округление выделения памяти для RDMA-клиентов |
|
|
||||||
| `--nfs_rdma_gc 64M` | максимальный объём неиспользуемой памяти RDMA-клиентом перед освобождением |
|
|
||||||
|
|
||||||
### upgrade
|
|
||||||
|
|
||||||
`vitastor-nfs --fs <NAME> upgrade`
|
|
||||||
|
|
||||||
Обновить метаданные ФС. Можно запускать онлайн (при запущенных серверах NFS), но после выполнения их всё
|
|
||||||
же желательно перезапустить.
|
|
||||||
|
|
||||||
### defrag
|
|
||||||
|
|
||||||
`vitastor-nfs --fs <NAME> defrag [OPTIONS] [--dry-run]`
|
|
||||||
|
|
||||||
Дефрагментировать тома, используемые для хранения мелких файлов, в которых более, чем
|
|
||||||
<defrag_percent> процентов данных удалено. Можно запускать онлайн.
|
|
||||||
|
|
||||||
На уровне реализации ФС файлы, меньшие, чем размер объекта пула (block_size умножить на число
|
|
||||||
частей данных, если пул EC), упаковываются друг за другом в большие "тома" / "общие иноды".
|
|
||||||
Когда такие файлы удаляются или увеличиваются, они перемещаются и оставляют за собой "мусор".
|
|
||||||
|
|
||||||
При дефрагментации мусор удаляется, а всё ещё используемые данные перемещаются в новые тома.
|
|
||||||
|
|
||||||
Опции:
|
|
||||||
|
|
||||||
| <!-- --> | <!-- --> |
|
|
||||||
|----------------------------|------------------------------------------------------------------------ |
|
|
||||||
| `--volume_untouched 86400` | Дефрагментировать только тома, в которые уже не писали это число секунд |
|
|
||||||
| `--defrag_percent 50` | Дефрагментировать только тома, в которых этот % данных удалён |
|
|
||||||
| `--defrag_block_count 16` | Читать это количество блоков пула за один раз |
|
|
||||||
| `--defrag_iodepth 16` | Перемещать одновременно до этого числа файлов |
|
|
||||||
| `--trace` | Печатать детальную статистику дефрагментации |
|
|
||||||
| `--dry-run` | Не производить никаких изменений, только описать выполняемые действия |
|
|
||||||
| `--recalc-stats` | Пересчитать и сохранить статистику всех томов |
|
|
||||||
| `--include-empty` | Дефрагментировать старые и пустые тома; обязательно перезапустите NFS-сервера после использования этой опции |
|
|
||||||
| `--no-rm` | Перемещать, но не удалять данные |
|
|
||||||
|
|
||||||
## Общие опции
|
## Общие опции
|
||||||
|
|
||||||
|
|
|
@ -151,9 +151,9 @@ Example performance comparison:
|
||||||
To try VDUSE you need at least Linux 5.15, built with VDUSE support
|
To try VDUSE you need at least Linux 5.15, built with VDUSE support
|
||||||
(CONFIG_VDPA=m, CONFIG_VDPA_USER=m, CONFIG_VIRTIO_VDPA=m).
|
(CONFIG_VDPA=m, CONFIG_VDPA_USER=m, CONFIG_VIRTIO_VDPA=m).
|
||||||
|
|
||||||
Debian Linux kernels had these options disabled until 6.6, so make sure you install a newer kernel
|
Debian Linux kernels have these options disabled by now, so if you want to try it on Debian,
|
||||||
(from bookworm-backports, trixie or newer Debian version) if you want to try VDUSE. You can also
|
use a kernel from Ubuntu [kernel-ppa/mainline](https://kernel.ubuntu.com/~kernel-ppa/mainline/), Proxmox,
|
||||||
build modules for an existing kernel manually:
|
or build modules for Debian kernel manually:
|
||||||
|
|
||||||
```
|
```
|
||||||
mkdir build
|
mkdir build
|
||||||
|
|
|
@ -154,9 +154,9 @@ VDUSE - на данный момент лучший интерфейс для п
|
||||||
Чтобы попробовать VDUSE, вам нужно ядро Linux как минимум версии 5.15, собранное с поддержкой
|
Чтобы попробовать VDUSE, вам нужно ядро Linux как минимум версии 5.15, собранное с поддержкой
|
||||||
VDUSE (CONFIG_VDPA=m, CONFIG_VDPA_USER=m, CONFIG_VIRTIO_VDPA=m).
|
VDUSE (CONFIG_VDPA=m, CONFIG_VDPA_USER=m, CONFIG_VIRTIO_VDPA=m).
|
||||||
|
|
||||||
В ядрах в Debian Linux эти опции включены, только начиная с 6.6, так что установите свежее ядро
|
В ядрах в Debian Linux поддержка пока отключена по умолчанию, так что чтобы попробовать VDUSE
|
||||||
из bookworm-backports, trixie или из более новой версии Debian, если хотите попробовать VDUSE.
|
на Debian, поставьте ядро из Ubuntu [kernel-ppa/mainline](https://kernel.ubuntu.com/~kernel-ppa/mainline/),
|
||||||
Либо же вы можете самостоятельно собрать модули для установленного ядра:
|
из Proxmox или соберите модули для ядра Debian вручную:
|
||||||
|
|
||||||
```
|
```
|
||||||
mkdir build
|
mkdir build
|
||||||
|
|
|
@ -11,7 +11,6 @@ module.exports = {
|
||||||
"ecmaVersion": 2020
|
"ecmaVersion": 2020
|
||||||
},
|
},
|
||||||
"plugins": [
|
"plugins": [
|
||||||
"import"
|
|
||||||
],
|
],
|
||||||
"rules": {
|
"rules": {
|
||||||
"indent": [
|
"indent": [
|
||||||
|
@ -45,10 +44,6 @@ module.exports = {
|
||||||
],
|
],
|
||||||
"node/shebang": [
|
"node/shebang": [
|
||||||
"off"
|
"off"
|
||||||
],
|
|
||||||
"import/no-unresolved": [
|
|
||||||
2,
|
|
||||||
{ "commonjs": true }
|
|
||||||
]
|
]
|
||||||
}
|
}
|
||||||
};
|
};
|
||||||
|
|
|
@ -1,188 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const AntiEtcd = require('antietcd');
|
|
||||||
|
|
||||||
const vitastor_persist_filter = require('./vitastor_persist_filter.js');
|
|
||||||
const { b64, local_ips } = require('./utils.js');
|
|
||||||
|
|
||||||
class AntiEtcdAdapter
|
|
||||||
{
|
|
||||||
static async start_antietcd(config)
|
|
||||||
{
|
|
||||||
let antietcd;
|
|
||||||
if (config.use_antietcd)
|
|
||||||
{
|
|
||||||
let cluster = config.etcd_address;
|
|
||||||
if (!(cluster instanceof Array))
|
|
||||||
cluster = cluster ? (''+(cluster||'')).split(/,+/) : [];
|
|
||||||
cluster = Object.keys(cluster.reduce((a, url) =>
|
|
||||||
{
|
|
||||||
a[url.toLowerCase().replace(/^(https?:\/\/)/, '').replace(/\/.*$/, '')] = true;
|
|
||||||
return a;
|
|
||||||
}, {}));
|
|
||||||
const cfg_port = config.antietcd_port;
|
|
||||||
const is_local = local_ips(true).reduce((a, c) => { a[c] = true; return a; }, {});
|
|
||||||
const selected = cluster.map(s => s.split(':', 2)).filter(ip => is_local[ip[0]] && (!cfg_port || ip[1] == cfg_port));
|
|
||||||
if (selected.length > 1)
|
|
||||||
{
|
|
||||||
console.error('More than 1 etcd_address matches local IPs, please specify port');
|
|
||||||
process.exit(1);
|
|
||||||
}
|
|
||||||
else if (selected.length == 1)
|
|
||||||
{
|
|
||||||
const antietcd_config = {
|
|
||||||
ip: selected[0][0],
|
|
||||||
port: selected[0][1],
|
|
||||||
data: config.antietcd_data_file || ((config.antietcd_data_dir || '/var/lib/vitastor') + '/mon_'+selected[0][1]+'.json.gz'),
|
|
||||||
persist_filter: vitastor_persist_filter({ vitastor_prefix: config.etcd_prefix || '/vitastor' }),
|
|
||||||
node_id: selected[0][0]+':'+selected[0][1], // node_id = ip:port
|
|
||||||
cluster: (cluster.length == 1 ? null : cluster.reduce((a, c) => { a[c] = "http://"+c; return a; }, {})),
|
|
||||||
cluster_key: (config.etcd_prefix || '/vitastor'),
|
|
||||||
stale_read: 1,
|
|
||||||
log_level: 1,
|
|
||||||
};
|
|
||||||
for (const key in config)
|
|
||||||
{
|
|
||||||
if (key.substr(0, 9) === 'antietcd_')
|
|
||||||
{
|
|
||||||
const noprefix = key.substr(9);
|
|
||||||
if (!(noprefix in antietcd_config) || noprefix == 'ip' || noprefix == 'cluster_key')
|
|
||||||
{
|
|
||||||
antietcd_config[noprefix] = config[key];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
console.log('Starting Antietcd node '+antietcd_config.node_id);
|
|
||||||
antietcd = new AntiEtcd(antietcd_config);
|
|
||||||
await antietcd.start();
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
console.log('Antietcd is enabled, but etcd_address does not contain local IPs, proceeding without it');
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return antietcd;
|
|
||||||
}
|
|
||||||
|
|
||||||
constructor(mon, antietcd)
|
|
||||||
{
|
|
||||||
this.mon = mon;
|
|
||||||
this.antietcd = antietcd;
|
|
||||||
this.on_leader = [];
|
|
||||||
this.on_change = (st) =>
|
|
||||||
{
|
|
||||||
if (st.state === 'leader')
|
|
||||||
{
|
|
||||||
for (const cb of this.on_leader)
|
|
||||||
{
|
|
||||||
cb();
|
|
||||||
}
|
|
||||||
this.on_leader = [];
|
|
||||||
}
|
|
||||||
};
|
|
||||||
this.antietcd.on('raftchange', this.on_change);
|
|
||||||
}
|
|
||||||
|
|
||||||
parse_config(/*config*/)
|
|
||||||
{
|
|
||||||
}
|
|
||||||
|
|
||||||
stop_watcher()
|
|
||||||
{
|
|
||||||
this.antietcd.off('raftchange', this.on_change);
|
|
||||||
const watch_id = this.watch_id;
|
|
||||||
if (watch_id)
|
|
||||||
{
|
|
||||||
this.watch_id = null;
|
|
||||||
this.antietcd.cancel_watch(watch_id).catch(console.error);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
async start_watcher()
|
|
||||||
{
|
|
||||||
if (this.watch_id)
|
|
||||||
{
|
|
||||||
await this.antietcd.cancel_watch(this.watch_id);
|
|
||||||
this.watch_id = null;
|
|
||||||
}
|
|
||||||
const watch_id = await this.antietcd.create_watch({
|
|
||||||
key: b64(this.mon.config.etcd_prefix+'/'),
|
|
||||||
range_end: b64(this.mon.config.etcd_prefix+'0'),
|
|
||||||
start_revision: ''+this.mon.etcd_watch_revision,
|
|
||||||
watch_id: 1,
|
|
||||||
progress_notify: true,
|
|
||||||
}, (message) =>
|
|
||||||
{
|
|
||||||
setImmediate(() => this.mon.on_message(message.result));
|
|
||||||
});
|
|
||||||
console.log('Successfully subscribed to antietcd revision '+this.antietcd.etctree.mod_revision);
|
|
||||||
this.watch_id = watch_id;
|
|
||||||
}
|
|
||||||
|
|
||||||
async become_master()
|
|
||||||
{
|
|
||||||
if (!this.antietcd.cluster)
|
|
||||||
{
|
|
||||||
console.log('Running in non-clustered mode');
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
console.log('Waiting to become master');
|
|
||||||
if (this.antietcd.cluster.raft.state !== 'leader')
|
|
||||||
{
|
|
||||||
await new Promise(ok => this.on_leader.push(ok));
|
|
||||||
}
|
|
||||||
}
|
|
||||||
const state = { ...this.mon.get_mon_state(), id: ''+this.mon.etcd_lease_id };
|
|
||||||
await this.etcd_call('/kv/txn', {
|
|
||||||
success: [ { requestPut: { key: b64(this.mon.config.etcd_prefix+'/mon/master'), value: b64(JSON.stringify(state)), lease: ''+this.mon.etcd_lease_id } } ],
|
|
||||||
}, this.mon.config.etcd_start_timeout, 0);
|
|
||||||
if (this.antietcd.cluster)
|
|
||||||
{
|
|
||||||
console.log('Became master');
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
async etcd_call(path, body, timeout, retries)
|
|
||||||
{
|
|
||||||
let retry = 0;
|
|
||||||
if (retries >= 0 && retries < 1)
|
|
||||||
{
|
|
||||||
retries = 1;
|
|
||||||
}
|
|
||||||
let prev = 0;
|
|
||||||
while (retries < 0 || retry < retries)
|
|
||||||
{
|
|
||||||
retry++;
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
throw new Error('Monitor instance is stopped');
|
|
||||||
}
|
|
||||||
try
|
|
||||||
{
|
|
||||||
if (Date.now()-prev < timeout)
|
|
||||||
{
|
|
||||||
await new Promise(ok => setTimeout(ok, timeout-(Date.now()-prev)));
|
|
||||||
}
|
|
||||||
prev = Date.now();
|
|
||||||
const res = await this.antietcd.api(path.replace(/^\/+/, '').replace(/\/+$/, '').replace(/\/+/g, '_'), body);
|
|
||||||
if (res.error)
|
|
||||||
{
|
|
||||||
console.error('Failed to query antietcd '+path+' (retry '+retry+'/'+retries+'): '+res.error);
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
return res;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
catch (e)
|
|
||||||
{
|
|
||||||
console.error('Failed to query antietcd '+path+' (retry '+retry+'/'+retries+'): '+e.stack);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
throw new Error('Failed to query antietcd ('+retries+' retries)');
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = AntiEtcdAdapter;
|
|
|
@ -1,352 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const http = require('http');
|
|
||||||
const WebSocket = require('ws');
|
|
||||||
const { b64, local_ips } = require('./utils.js');
|
|
||||||
|
|
||||||
const MON_STOPPED = 'Monitor instance is stopped';
|
|
||||||
|
|
||||||
class EtcdAdapter
|
|
||||||
{
|
|
||||||
constructor(mon)
|
|
||||||
{
|
|
||||||
this.mon = mon;
|
|
||||||
this.ws = null;
|
|
||||||
this.ws_alive = false;
|
|
||||||
this.ws_keepalive_timer = null;
|
|
||||||
}
|
|
||||||
|
|
||||||
parse_config(config)
|
|
||||||
{
|
|
||||||
this.parse_etcd_addresses(config.etcd_address||config.etcd_url);
|
|
||||||
}
|
|
||||||
|
|
||||||
parse_etcd_addresses(addrs)
|
|
||||||
{
|
|
||||||
const is_local_ip = local_ips(true).reduce((a, c) => { a[c] = true; return a; }, {});
|
|
||||||
this.etcd_local = [];
|
|
||||||
this.etcd_urls = [];
|
|
||||||
this.selected_etcd_url = null;
|
|
||||||
this.etcd_urls_to_try = [];
|
|
||||||
if (!(addrs instanceof Array))
|
|
||||||
addrs = addrs ? (''+(addrs||'')).split(/,/) : [];
|
|
||||||
if (!addrs.length)
|
|
||||||
{
|
|
||||||
console.error('Vitastor etcd address(es) not specified. Please set on the command line or in the config file');
|
|
||||||
process.exit(1);
|
|
||||||
}
|
|
||||||
for (let url of addrs)
|
|
||||||
{
|
|
||||||
let scheme = 'http';
|
|
||||||
url = url.trim().replace(/^(https?):\/\//, (m, m1) => { scheme = m1; return ''; });
|
|
||||||
const slash = url.indexOf('/');
|
|
||||||
const colon = url.indexOf(':');
|
|
||||||
const is_local = is_local_ip[colon >= 0 ? url.substr(0, colon) : (slash >= 0 ? url.substr(0, slash) : url)];
|
|
||||||
url = scheme+'://'+(slash >= 0 ? url : url+'/v3');
|
|
||||||
if (is_local)
|
|
||||||
this.etcd_local.push(url);
|
|
||||||
else
|
|
||||||
this.etcd_urls.push(url);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
pick_next_etcd()
|
|
||||||
{
|
|
||||||
if (this.selected_etcd_url)
|
|
||||||
return this.selected_etcd_url;
|
|
||||||
if (!this.etcd_urls_to_try || !this.etcd_urls_to_try.length)
|
|
||||||
{
|
|
||||||
this.etcd_urls_to_try = [ ...this.etcd_local ];
|
|
||||||
const others = [ ...this.etcd_urls ];
|
|
||||||
while (others.length)
|
|
||||||
{
|
|
||||||
const url = others.splice(0|(others.length*Math.random()), 1);
|
|
||||||
this.etcd_urls_to_try.push(url[0]);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
this.selected_etcd_url = this.etcd_urls_to_try.shift();
|
|
||||||
return this.selected_etcd_url;
|
|
||||||
}
|
|
||||||
|
|
||||||
stop_watcher(cur_addr)
|
|
||||||
{
|
|
||||||
cur_addr = cur_addr || this.selected_etcd_url;
|
|
||||||
if (this.ws)
|
|
||||||
{
|
|
||||||
console.log('Disconnected from etcd at '+this.ws_used_url);
|
|
||||||
this.ws.close();
|
|
||||||
this.ws = null;
|
|
||||||
}
|
|
||||||
if (this.ws_keepalive_timer)
|
|
||||||
{
|
|
||||||
clearInterval(this.ws_keepalive_timer);
|
|
||||||
this.ws_keepalive_timer = null;
|
|
||||||
}
|
|
||||||
if (this.selected_etcd_url == cur_addr)
|
|
||||||
{
|
|
||||||
this.selected_etcd_url = null;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
restart_watcher(cur_addr)
|
|
||||||
{
|
|
||||||
this.stop_watcher(cur_addr);
|
|
||||||
this.start_watcher(this.mon.config.etcd_mon_retries).catch(this.mon.die);
|
|
||||||
}
|
|
||||||
|
|
||||||
async start_watcher(retries)
|
|
||||||
{
|
|
||||||
let retry = 0;
|
|
||||||
if (!retries || retries < 1)
|
|
||||||
{
|
|
||||||
retries = 1;
|
|
||||||
}
|
|
||||||
const tried = {};
|
|
||||||
while (retries < 0 || retry < retries)
|
|
||||||
{
|
|
||||||
const cur_addr = this.pick_next_etcd();
|
|
||||||
const base = 'ws'+cur_addr.substr(4);
|
|
||||||
let now = Date.now();
|
|
||||||
if (tried[base] && now-tried[base] < this.mon.config.etcd_start_timeout)
|
|
||||||
{
|
|
||||||
await new Promise(ok => setTimeout(ok, this.mon.config.etcd_start_timeout-(now-tried[base])));
|
|
||||||
now = Date.now();
|
|
||||||
}
|
|
||||||
tried[base] = now;
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
const ok = await new Promise(ok =>
|
|
||||||
{
|
|
||||||
const timer_id = setTimeout(() =>
|
|
||||||
{
|
|
||||||
if (this.ws)
|
|
||||||
{
|
|
||||||
console.log('Disconnected from etcd at '+this.ws_used_url);
|
|
||||||
this.ws.close();
|
|
||||||
this.ws = null;
|
|
||||||
}
|
|
||||||
ok(false);
|
|
||||||
}, this.mon.config.etcd_mon_timeout);
|
|
||||||
this.ws = new WebSocket(base+'/watch');
|
|
||||||
this.ws_used_url = cur_addr;
|
|
||||||
const fail = () =>
|
|
||||||
{
|
|
||||||
ok(false);
|
|
||||||
};
|
|
||||||
this.ws.on('error', fail);
|
|
||||||
this.ws.on('open', () =>
|
|
||||||
{
|
|
||||||
this.ws.removeListener('error', fail);
|
|
||||||
if (timer_id)
|
|
||||||
clearTimeout(timer_id);
|
|
||||||
ok(true);
|
|
||||||
});
|
|
||||||
});
|
|
||||||
if (ok)
|
|
||||||
break;
|
|
||||||
if (this.selected_etcd_url == cur_addr)
|
|
||||||
this.selected_etcd_url = null;
|
|
||||||
this.ws = null;
|
|
||||||
retry++;
|
|
||||||
}
|
|
||||||
if (!this.ws)
|
|
||||||
{
|
|
||||||
this.mon.die('Failed to open etcd watch websocket');
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
this.stop_watcher();
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
const cur_addr = this.selected_etcd_url;
|
|
||||||
this.ws_alive = true;
|
|
||||||
this.ws_keepalive_timer = setInterval(() =>
|
|
||||||
{
|
|
||||||
if (this.ws_alive && this.ws)
|
|
||||||
{
|
|
||||||
this.ws_alive = false;
|
|
||||||
this.ws.send(JSON.stringify({ progress_request: {} }));
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
console.log('etcd websocket timed out, restarting it');
|
|
||||||
this.restart_watcher(cur_addr);
|
|
||||||
}
|
|
||||||
}, (Number(this.mon.config.etcd_ws_keepalive_interval) || 5)*1000);
|
|
||||||
this.ws.on('error', () => this.restart_watcher(cur_addr));
|
|
||||||
this.ws.send(JSON.stringify({
|
|
||||||
create_request: {
|
|
||||||
key: b64(this.mon.config.etcd_prefix+'/'),
|
|
||||||
range_end: b64(this.mon.config.etcd_prefix+'0'),
|
|
||||||
start_revision: ''+this.mon.etcd_watch_revision,
|
|
||||||
watch_id: 1,
|
|
||||||
progress_notify: true,
|
|
||||||
},
|
|
||||||
}));
|
|
||||||
this.ws.on('message', (msg) =>
|
|
||||||
{
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
this.stop_watcher();
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
this.ws_alive = true;
|
|
||||||
let data;
|
|
||||||
try
|
|
||||||
{
|
|
||||||
data = JSON.parse(msg);
|
|
||||||
}
|
|
||||||
catch (e)
|
|
||||||
{
|
|
||||||
}
|
|
||||||
if (!data || !data.result)
|
|
||||||
{
|
|
||||||
console.error('Unknown message received from watch websocket: '+msg);
|
|
||||||
}
|
|
||||||
else if (data.result.canceled)
|
|
||||||
{
|
|
||||||
// etcd watch canceled
|
|
||||||
if (data.result.compact_revision)
|
|
||||||
{
|
|
||||||
// we may miss events if we proceed
|
|
||||||
this.mon.die('Revisions before '+data.result.compact_revision+' were compacted by etcd, exiting');
|
|
||||||
}
|
|
||||||
this.mon.die('Watch canceled by etcd, reason: '+data.result.cancel_reason+', exiting');
|
|
||||||
}
|
|
||||||
else if (data.result.created)
|
|
||||||
{
|
|
||||||
// etcd watch created
|
|
||||||
console.log('Successfully subscribed to etcd at '+this.selected_etcd_url+', revision '+data.result.header.revision);
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
this.mon.on_message(data.result);
|
|
||||||
}
|
|
||||||
});
|
|
||||||
}
|
|
||||||
|
|
||||||
async become_master()
|
|
||||||
{
|
|
||||||
const state = { ...this.mon.get_mon_state(), id: ''+this.mon.etcd_lease_id };
|
|
||||||
console.log('Waiting to become master');
|
|
||||||
// eslint-disable-next-line no-constant-condition
|
|
||||||
while (1)
|
|
||||||
{
|
|
||||||
const res = await this.etcd_call('/kv/txn', {
|
|
||||||
compare: [ { target: 'CREATE', create_revision: 0, key: b64(this.mon.config.etcd_prefix+'/mon/master') } ],
|
|
||||||
success: [ { requestPut: { key: b64(this.mon.config.etcd_prefix+'/mon/master'), value: b64(JSON.stringify(state)), lease: ''+this.mon.etcd_lease_id } } ],
|
|
||||||
}, this.mon.config.etcd_start_timeout, 0);
|
|
||||||
if (res.succeeded)
|
|
||||||
{
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
await new Promise(ok => setTimeout(ok, this.mon.config.etcd_start_timeout));
|
|
||||||
}
|
|
||||||
console.log('Became master');
|
|
||||||
}
|
|
||||||
|
|
||||||
async etcd_call(path, body, timeout, retries)
|
|
||||||
{
|
|
||||||
let retry = 0;
|
|
||||||
if (retries >= 0 && retries < 1)
|
|
||||||
{
|
|
||||||
retries = 1;
|
|
||||||
}
|
|
||||||
const tried = {};
|
|
||||||
while (retries < 0 || retry < retries)
|
|
||||||
{
|
|
||||||
retry++;
|
|
||||||
const base = this.pick_next_etcd();
|
|
||||||
let now = Date.now();
|
|
||||||
if (tried[base] && now-tried[base] < timeout)
|
|
||||||
{
|
|
||||||
await new Promise(ok => setTimeout(ok, timeout-(now-tried[base])));
|
|
||||||
now = Date.now();
|
|
||||||
}
|
|
||||||
tried[base] = now;
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
throw new Error(MON_STOPPED);
|
|
||||||
}
|
|
||||||
const res = await POST(base+path, body, timeout);
|
|
||||||
if (this.mon.stopped)
|
|
||||||
{
|
|
||||||
throw new Error(MON_STOPPED);
|
|
||||||
}
|
|
||||||
if (res.error)
|
|
||||||
{
|
|
||||||
if (this.selected_etcd_url == base)
|
|
||||||
this.selected_etcd_url = null;
|
|
||||||
console.error('Failed to query etcd '+path+' (retry '+retry+'/'+retries+'): '+res.error);
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
if (res.json)
|
|
||||||
{
|
|
||||||
if (res.json.error)
|
|
||||||
{
|
|
||||||
console.error(path+': etcd returned error: '+res.json.error);
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
return res.json;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
throw new Error('Failed to query etcd ('+retries+' retries)');
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
function POST(url, body, timeout)
|
|
||||||
{
|
|
||||||
return new Promise(ok =>
|
|
||||||
{
|
|
||||||
const body_text = Buffer.from(JSON.stringify(body));
|
|
||||||
let timer_id = timeout > 0 ? setTimeout(() =>
|
|
||||||
{
|
|
||||||
if (req)
|
|
||||||
req.abort();
|
|
||||||
req = null;
|
|
||||||
ok({ error: 'timeout' });
|
|
||||||
}, timeout) : null;
|
|
||||||
let req = http.request(url, { method: 'POST', headers: {
|
|
||||||
'Content-Type': 'application/json',
|
|
||||||
'Content-Length': body_text.length,
|
|
||||||
} }, (res) =>
|
|
||||||
{
|
|
||||||
if (!req)
|
|
||||||
{
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
clearTimeout(timer_id);
|
|
||||||
let res_body = '';
|
|
||||||
res.setEncoding('utf8');
|
|
||||||
res.on('error', (error) => ok({ error }));
|
|
||||||
res.on('data', chunk => { res_body += chunk; });
|
|
||||||
res.on('end', () =>
|
|
||||||
{
|
|
||||||
if (res.statusCode != 200)
|
|
||||||
{
|
|
||||||
ok({ error: res_body, code: res.statusCode });
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
try
|
|
||||||
{
|
|
||||||
res_body = JSON.parse(res_body);
|
|
||||||
ok({ response: res, json: res_body });
|
|
||||||
}
|
|
||||||
catch (e)
|
|
||||||
{
|
|
||||||
ok({ error: e, response: res, body: res_body });
|
|
||||||
}
|
|
||||||
});
|
|
||||||
});
|
|
||||||
req.on('error', (error) => ok({ error }));
|
|
||||||
req.on('close', () => ok({ error: new Error('Connection closed prematurely') }));
|
|
||||||
req.write(body_text);
|
|
||||||
req.end();
|
|
||||||
});
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = EtcdAdapter;
|
|
|
@ -1,397 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
// FIXME document all etcd keys and config variables in the form of JSON schema or similar
|
|
||||||
const etcd_nonempty_keys = {
|
|
||||||
'config/global': 1,
|
|
||||||
'config/node_placement': 1,
|
|
||||||
'config/pools': 1,
|
|
||||||
'pg/config': 1,
|
|
||||||
'history/last_clean_pgs': 1,
|
|
||||||
'stats': 1,
|
|
||||||
};
|
|
||||||
const etcd_allow = new RegExp('^'+[
|
|
||||||
'config/global',
|
|
||||||
'config/node_placement',
|
|
||||||
'config/pools',
|
|
||||||
'config/osd/[1-9]\\d*',
|
|
||||||
'config/pgs', // old name
|
|
||||||
'pg/config',
|
|
||||||
'config/inode/[1-9]\\d*/[1-9]\\d*',
|
|
||||||
'osd/state/[1-9]\\d*',
|
|
||||||
'osd/stats/[1-9]\\d*',
|
|
||||||
'osd/inodestats/[1-9]\\d*',
|
|
||||||
'osd/space/[1-9]\\d*',
|
|
||||||
'mon/master',
|
|
||||||
'mon/member/[a-f0-9]+',
|
|
||||||
'pg/state/[1-9]\\d*/[1-9]\\d*',
|
|
||||||
'pg/stats/[1-9]\\d*/[1-9]\\d*', // old name
|
|
||||||
'pgstats/[1-9]\\d*/[1-9]\\d*',
|
|
||||||
'pg/history/[1-9]\\d*/[1-9]\\d*',
|
|
||||||
'history/last_clean_pgs',
|
|
||||||
'inode/stats/[1-9]\\d*/\\d+',
|
|
||||||
'pool/stats/[1-9]\\d*',
|
|
||||||
'stats',
|
|
||||||
'index/image/.*',
|
|
||||||
'index/maxid/[1-9]\\d*',
|
|
||||||
].join('$|^')+'$');
|
|
||||||
|
|
||||||
const etcd_tree = {
|
|
||||||
config: {
|
|
||||||
/* global: {
|
|
||||||
// WARNING: NOT ALL OF THESE ARE ACTUALLY CONFIGURABLE HERE
|
|
||||||
// THIS IS JUST A POOR MAN'S CONFIG DOCUMENTATION
|
|
||||||
// etcd connection
|
|
||||||
config_path: "/etc/vitastor/vitastor.conf",
|
|
||||||
etcd_prefix: "/vitastor",
|
|
||||||
// etcd connection - configurable online
|
|
||||||
etcd_address: "10.0.115.10:2379/v3",
|
|
||||||
// mon
|
|
||||||
etcd_mon_ttl: 5, // min: 1
|
|
||||||
etcd_mon_timeout: 1000, // ms. min: 0
|
|
||||||
etcd_mon_retries: 5, // min: 0
|
|
||||||
mon_change_timeout: 1000, // ms. min: 100
|
|
||||||
mon_retry_change_timeout: 50, // ms. min: 10
|
|
||||||
mon_stats_timeout: 1000, // ms. min: 100
|
|
||||||
osd_out_time: 600, // seconds. min: 0
|
|
||||||
placement_levels: { datacenter: 1, rack: 2, host: 3, osd: 4, ... },
|
|
||||||
use_old_pg_combinator: false,
|
|
||||||
osd_backfillfull_ratio: 0.99,
|
|
||||||
// client and osd
|
|
||||||
tcp_header_buffer_size: 65536,
|
|
||||||
use_sync_send_recv: false,
|
|
||||||
use_rdma: true,
|
|
||||||
rdma_device: null, // for example, "rocep5s0f0"
|
|
||||||
rdma_port_num: 1,
|
|
||||||
rdma_gid_index: 0,
|
|
||||||
rdma_mtu: 4096,
|
|
||||||
rdma_max_sge: 128,
|
|
||||||
rdma_max_send: 8,
|
|
||||||
rdma_max_recv: 16,
|
|
||||||
rdma_max_msg: 132096,
|
|
||||||
block_size: 131072,
|
|
||||||
disk_alignment: 4096,
|
|
||||||
bitmap_granularity: 4096,
|
|
||||||
immediate_commit: 'all', // 'none', 'all' or 'small'
|
|
||||||
// client - configurable online
|
|
||||||
client_max_dirty_bytes: 33554432,
|
|
||||||
client_max_dirty_ops: 1024,
|
|
||||||
client_enable_writeback: false,
|
|
||||||
client_max_buffered_bytes: 33554432,
|
|
||||||
client_max_buffered_ops: 1024,
|
|
||||||
client_max_writeback_iodepth: 256,
|
|
||||||
client_retry_interval: 50, // ms. min: 10
|
|
||||||
client_eio_retry_interval: 1000, // ms
|
|
||||||
client_retry_enospc: true,
|
|
||||||
osd_nearfull_ratio: 0.95,
|
|
||||||
// client and osd - configurable online
|
|
||||||
log_level: 0,
|
|
||||||
peer_connect_interval: 5, // seconds. min: 1
|
|
||||||
peer_connect_timeout: 5, // seconds. min: 1
|
|
||||||
osd_idle_timeout: 5, // seconds. min: 1
|
|
||||||
osd_ping_timeout: 5, // seconds. min: 1
|
|
||||||
max_etcd_attempts: 5,
|
|
||||||
etcd_quick_timeout: 1000, // ms
|
|
||||||
etcd_slow_timeout: 5000, // ms
|
|
||||||
etcd_keepalive_timeout: 30, // seconds, default is max(30, etcd_report_interval*2)
|
|
||||||
etcd_ws_keepalive_interval: 5, // seconds
|
|
||||||
// osd
|
|
||||||
etcd_report_interval: 5, // seconds
|
|
||||||
etcd_stats_interval: 30, // seconds
|
|
||||||
run_primary: true,
|
|
||||||
osd_network: null, // "192.168.7.0/24" or an array of masks
|
|
||||||
bind_address: "0.0.0.0",
|
|
||||||
bind_port: 0,
|
|
||||||
readonly: false,
|
|
||||||
osd_memlock: false,
|
|
||||||
// osd - configurable online
|
|
||||||
autosync_interval: 5,
|
|
||||||
autosync_writes: 128,
|
|
||||||
client_queue_depth: 128, // unused
|
|
||||||
recovery_queue_depth: 1,
|
|
||||||
recovery_sleep_us: 0,
|
|
||||||
recovery_tune_util_low: 0.1,
|
|
||||||
recovery_tune_client_util_low: 0,
|
|
||||||
recovery_tune_util_high: 1.0,
|
|
||||||
recovery_tune_client_util_high: 0.5,
|
|
||||||
recovery_tune_interval: 1,
|
|
||||||
recovery_tune_agg_interval: 10, // 10 times recovery_tune_interval
|
|
||||||
recovery_tune_sleep_min_us: 10, // 10 microseconds
|
|
||||||
recovery_pg_switch: 128,
|
|
||||||
recovery_sync_batch: 16,
|
|
||||||
no_recovery: false,
|
|
||||||
no_rebalance: false,
|
|
||||||
print_stats_interval: 3,
|
|
||||||
slow_log_interval: 10,
|
|
||||||
inode_vanish_time: 60,
|
|
||||||
auto_scrub: false,
|
|
||||||
no_scrub: false,
|
|
||||||
scrub_interval: '30d', // 1s/1m/1h/1d
|
|
||||||
scrub_queue_depth: 1,
|
|
||||||
scrub_sleep: 0, // milliseconds
|
|
||||||
scrub_list_limit: 1000, // objects to list on one scrub iteration
|
|
||||||
scrub_find_best: true,
|
|
||||||
scrub_ec_max_bruteforce: 100, // maximum EC error locator brute-force iterators
|
|
||||||
// blockstore - fixed in superblock
|
|
||||||
block_size,
|
|
||||||
disk_alignment,
|
|
||||||
journal_block_size,
|
|
||||||
meta_block_size,
|
|
||||||
bitmap_granularity,
|
|
||||||
journal_device,
|
|
||||||
journal_offset,
|
|
||||||
journal_size,
|
|
||||||
disable_journal_fsync,
|
|
||||||
data_device,
|
|
||||||
data_offset,
|
|
||||||
data_size,
|
|
||||||
disable_data_fsync,
|
|
||||||
meta_device,
|
|
||||||
meta_offset,
|
|
||||||
disable_meta_fsync,
|
|
||||||
disable_device_lock,
|
|
||||||
// blockstore - configurable offline
|
|
||||||
inmemory_metadata,
|
|
||||||
inmemory_journal,
|
|
||||||
journal_sector_buffer_count,
|
|
||||||
journal_no_same_sector_overwrites,
|
|
||||||
// blockstore - configurable online
|
|
||||||
max_write_iodepth,
|
|
||||||
min_flusher_count: 1,
|
|
||||||
max_flusher_count: 256,
|
|
||||||
throttle_small_writes: false,
|
|
||||||
throttle_target_iops: 100,
|
|
||||||
throttle_target_mbs: 100,
|
|
||||||
throttle_target_parallelism: 1,
|
|
||||||
throttle_threshold_us: 50,
|
|
||||||
}, */
|
|
||||||
global: {},
|
|
||||||
/* node_placement: {
|
|
||||||
host1: { level: 'host', parent: 'rack1' },
|
|
||||||
...
|
|
||||||
}, */
|
|
||||||
node_placement: {},
|
|
||||||
/* pools: {
|
|
||||||
<id>: {
|
|
||||||
name: 'testpool',
|
|
||||||
// 'ec' uses Reed-Solomon-Vandermonde codes, 'jerasure' is an alias for 'ec'
|
|
||||||
scheme: 'replicated' | 'xor' | 'ec' | 'jerasure',
|
|
||||||
pg_size: 3,
|
|
||||||
pg_minsize: 2,
|
|
||||||
// number of parity chunks, required for EC
|
|
||||||
parity_chunks?: 1,
|
|
||||||
pg_count: 100,
|
|
||||||
// default is failure_domain=host
|
|
||||||
failure_domain?: 'host',
|
|
||||||
// additional failure domain rules; failure_domain=x is equivalent to x=123..N
|
|
||||||
level_placement?: 'dc=112233 host=123456',
|
|
||||||
raw_placement?: 'any, dc=1 host!=1, dc=1 host!=(1,2)',
|
|
||||||
old_combinator: false,
|
|
||||||
max_osd_combinations: 10000,
|
|
||||||
// block_size, bitmap_granularity, immediate_commit must match all OSDs used in that pool
|
|
||||||
block_size: 131072,
|
|
||||||
bitmap_granularity: 4096,
|
|
||||||
// 'all'/'small'/'none', same as in OSD options
|
|
||||||
immediate_commit: 'all',
|
|
||||||
pg_stripe_size: 0,
|
|
||||||
root_node?: 'rack1',
|
|
||||||
// restrict pool to OSDs having all of these tags
|
|
||||||
osd_tags?: 'nvme' | [ 'nvme', ... ],
|
|
||||||
// prefer to put primary on OSD with these tags
|
|
||||||
primary_affinity_tags?: 'nvme' | [ 'nvme', ... ],
|
|
||||||
// scrub interval
|
|
||||||
scrub_interval?: '30d',
|
|
||||||
},
|
|
||||||
...
|
|
||||||
}, */
|
|
||||||
pools: {},
|
|
||||||
osd: {
|
|
||||||
/* <id>: { reweight?: 1, tags?: [ 'nvme', ... ], noout?: true }, ... */
|
|
||||||
},
|
|
||||||
/* inode: {
|
|
||||||
<pool_id>: {
|
|
||||||
<inode_t>: {
|
|
||||||
name: string,
|
|
||||||
size?: uint64_t, // bytes
|
|
||||||
parent_pool?: <pool_id>,
|
|
||||||
parent_id?: <inode_t>,
|
|
||||||
readonly?: boolean,
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}, */
|
|
||||||
inode: {},
|
|
||||||
},
|
|
||||||
osd: {
|
|
||||||
state: {
|
|
||||||
/* <osd_num_t>: {
|
|
||||||
state: "up",
|
|
||||||
addresses: string[],
|
|
||||||
host: string,
|
|
||||||
port: uint16_t,
|
|
||||||
primary_enabled: boolean,
|
|
||||||
blockstore_enabled: boolean,
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
stats: {
|
|
||||||
/* <osd_num_t>: {
|
|
||||||
time: number, // unix time
|
|
||||||
data_block_size: uint64_t, // bytes
|
|
||||||
bitmap_granularity: uint64_t, // bytes
|
|
||||||
immediate_commit: "all"|"small"|"none",
|
|
||||||
blockstore_ready: boolean,
|
|
||||||
size: uint64_t, // bytes
|
|
||||||
free: uint64_t, // bytes
|
|
||||||
host: string,
|
|
||||||
op_stats: {
|
|
||||||
<string>: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
|
||||||
},
|
|
||||||
subop_stats: {
|
|
||||||
<string>: { count: uint64_t, usec: uint64_t },
|
|
||||||
},
|
|
||||||
recovery_stats: {
|
|
||||||
degraded: { count: uint64_t, bytes: uint64_t },
|
|
||||||
misplaced: { count: uint64_t, bytes: uint64_t },
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
inodestats: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
<inode_t>: {
|
|
||||||
read: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
|
||||||
write: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
|
||||||
delete: { count: uint64_t, usec: uint64_t, bytes: uint64_t },
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
space: {
|
|
||||||
/* <osd_num_t>: {
|
|
||||||
<pool_id>: {
|
|
||||||
<inode_t>: uint64_t, // bytes
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
mon: {
|
|
||||||
master: {
|
|
||||||
/* ip: [ string ], id: uint64_t */
|
|
||||||
},
|
|
||||||
member: {
|
|
||||||
/* <uint64_t>: { ip: [ string ] }, */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
pg: {
|
|
||||||
/* config: {
|
|
||||||
hash: string,
|
|
||||||
items: {
|
|
||||||
<pool_id>: {
|
|
||||||
<pg_id>: {
|
|
||||||
osd_set: [ 1, 2, 3 ],
|
|
||||||
primary: 1,
|
|
||||||
pause: false,
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}, */
|
|
||||||
config: {},
|
|
||||||
state: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
<pg_id>: {
|
|
||||||
primary: osd_num_t,
|
|
||||||
state: ("starting"|"peering"|"incomplete"|"active"|"repeering"|"stopping"|"offline"|
|
|
||||||
"degraded"|"has_incomplete"|"has_degraded"|"has_misplaced"|"has_unclean"|
|
|
||||||
"has_invalid"|"has_inconsistent"|"has_corrupted"|"left_on_dead"|"scrubbing")[],
|
|
||||||
}
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
history: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
<pg_id>: {
|
|
||||||
osd_sets: osd_num_t[][],
|
|
||||||
all_peers: osd_num_t[],
|
|
||||||
epoch: uint64_t,
|
|
||||||
next_scrub: uint64_t,
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
pgstats: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
<pg_id>: {
|
|
||||||
object_count: uint64_t,
|
|
||||||
clean_count: uint64_t,
|
|
||||||
misplaced_count: uint64_t,
|
|
||||||
degraded_count: uint64_t,
|
|
||||||
incomplete_count: uint64_t,
|
|
||||||
write_osd_set: osd_num_t[],
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
inode: {
|
|
||||||
stats: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
<inode_t>: {
|
|
||||||
raw_used: uint64_t, // raw used bytes on OSDs
|
|
||||||
read: { count: uint64_t, usec: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t, lat: uint64_t },
|
|
||||||
write: { count: uint64_t, usec: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t, lat: uint64_t },
|
|
||||||
delete: { count: uint64_t, usec: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t, lat: uint64_t },
|
|
||||||
},
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
pool: {
|
|
||||||
stats: {
|
|
||||||
/* <pool_id>: {
|
|
||||||
used_raw_tb: float, // used raw space in the pool
|
|
||||||
total_raw_tb: float, // maximum amount of space in the pool
|
|
||||||
raw_to_usable: float, // raw to usable ratio
|
|
||||||
space_efficiency: float, // 0..1
|
|
||||||
} */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
stats: {
|
|
||||||
/* op_stats: {
|
|
||||||
<string>: { count: uint64_t, usec: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t, lat: uint64_t },
|
|
||||||
},
|
|
||||||
subop_stats: {
|
|
||||||
<string>: { count: uint64_t, usec: uint64_t, iops: uint64_t, lat: uint64_t },
|
|
||||||
},
|
|
||||||
recovery_stats: {
|
|
||||||
degraded: { count: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t },
|
|
||||||
misplaced: { count: uint64_t, bytes: uint64_t, bps: uint64_t, iops: uint64_t },
|
|
||||||
},
|
|
||||||
object_counts: {
|
|
||||||
object: uint64_t,
|
|
||||||
clean: uint64_t,
|
|
||||||
misplaced: uint64_t,
|
|
||||||
degraded: uint64_t,
|
|
||||||
incomplete: uint64_t,
|
|
||||||
},
|
|
||||||
object_bytes: {
|
|
||||||
total: uint64_t,
|
|
||||||
clean: uint64_t,
|
|
||||||
misplaced: uint64_t,
|
|
||||||
degraded: uint64_t,
|
|
||||||
incomplete: uint64_t,
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
history: {
|
|
||||||
last_clean_pgs: {},
|
|
||||||
},
|
|
||||||
index: {
|
|
||||||
image: {
|
|
||||||
/* <name>: {
|
|
||||||
id: uint64_t,
|
|
||||||
pool_id: uint64_t,
|
|
||||||
}, */
|
|
||||||
},
|
|
||||||
maxid: {
|
|
||||||
/* <pool_id>: uint64_t, */
|
|
||||||
},
|
|
||||||
},
|
|
||||||
};
|
|
||||||
|
|
||||||
module.exports = {
|
|
||||||
etcd_nonempty_keys,
|
|
||||||
etcd_allow,
|
|
||||||
etcd_tree,
|
|
||||||
};
|
|
|
@ -1,50 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const fsp = require('fs').promises;
|
|
||||||
const http = require('http');
|
|
||||||
const https = require('https');
|
|
||||||
|
|
||||||
async function create_http_server(cfg, handler)
|
|
||||||
{
|
|
||||||
let server;
|
|
||||||
if (cfg.mon_https_cert)
|
|
||||||
{
|
|
||||||
const tls = {
|
|
||||||
key: await fsp.readFile(cfg.mon_https_key),
|
|
||||||
cert: await fsp.readFile(cfg.mon_https_cert),
|
|
||||||
};
|
|
||||||
if (cfg.mon_https_ca)
|
|
||||||
{
|
|
||||||
tls.mon_https_ca = await fsp.readFile(cfg.mon_https_ca);
|
|
||||||
}
|
|
||||||
if (cfg.mon_https_client_auth)
|
|
||||||
{
|
|
||||||
tls.requestCert = true;
|
|
||||||
}
|
|
||||||
server = https.createServer(tls, handler);
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
server = http.createServer(handler);
|
|
||||||
}
|
|
||||||
try
|
|
||||||
{
|
|
||||||
let err;
|
|
||||||
server.once('error', e => err = e);
|
|
||||||
server.listen(cfg.mon_http_port || 8060, cfg.mon_http_ip || undefined);
|
|
||||||
if (err)
|
|
||||||
throw err;
|
|
||||||
}
|
|
||||||
catch (e)
|
|
||||||
{
|
|
||||||
console.error(
|
|
||||||
'HTTP server disabled because listen at address: '+
|
|
||||||
(cfg.mon_http_ip || '')+':'+(cfg.mon_http_port || 9090)+' failed with error: '+e
|
|
||||||
);
|
|
||||||
return null;
|
|
||||||
}
|
|
||||||
return server;
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = { create_http_server };
|
|
|
@ -23,4 +23,4 @@ for (let i = 2; i < process.argv.length; i++)
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
Mon.run_forever(options).catch(console.error);
|
new Mon(options).start().catch(e => { console.error(e); process.exit(1); });
|
||||||
|
|
2088
mon/mon.js
2088
mon/mon.js
File diff suppressed because it is too large
Load Diff
215
mon/osd_tree.js
215
mon/osd_tree.js
|
@ -1,215 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
function get_osd_tree(global_config, state)
|
|
||||||
{
|
|
||||||
const levels = global_config.placement_levels||{};
|
|
||||||
levels.host = levels.host || 100;
|
|
||||||
levels.osd = levels.osd || 101;
|
|
||||||
const tree = {};
|
|
||||||
let up_osds = {};
|
|
||||||
// This requires monitor system time to be in sync with OSD system times (at least to some extent)
|
|
||||||
const down_time = Date.now()/1000 - global_config.osd_out_time;
|
|
||||||
for (const osd_num of Object.keys(state.osd.stats).sort((a, b) => a - b))
|
|
||||||
{
|
|
||||||
const stat = state.osd.stats[osd_num];
|
|
||||||
const osd_cfg = state.config.osd[osd_num];
|
|
||||||
let reweight = osd_cfg == null ? 1 : Number(osd_cfg.reweight);
|
|
||||||
if (reweight < 0 || isNaN(reweight))
|
|
||||||
reweight = 1;
|
|
||||||
if (stat && stat.size && reweight && (state.osd.state[osd_num] || Number(stat.time) >= down_time ||
|
|
||||||
osd_cfg && osd_cfg.noout))
|
|
||||||
{
|
|
||||||
// Numeric IDs are reserved for OSDs
|
|
||||||
if (state.osd.state[osd_num] && reweight > 0)
|
|
||||||
{
|
|
||||||
// React to down OSDs immediately
|
|
||||||
up_osds[osd_num] = true;
|
|
||||||
}
|
|
||||||
tree[osd_num] = tree[osd_num] || {};
|
|
||||||
tree[osd_num].id = osd_num;
|
|
||||||
tree[osd_num].parent = tree[osd_num].parent || stat.host;
|
|
||||||
tree[osd_num].level = 'osd';
|
|
||||||
tree[osd_num].size = reweight * stat.size / 1024 / 1024 / 1024 / 1024; // terabytes
|
|
||||||
if (osd_cfg && osd_cfg.tags)
|
|
||||||
{
|
|
||||||
tree[osd_num].tags = (osd_cfg.tags instanceof Array ? [ ...osd_cfg.tags ] : [ osd_cfg.tags ])
|
|
||||||
.reduce((a, c) => { a[c] = true; return a; }, {});
|
|
||||||
}
|
|
||||||
delete tree[osd_num].children;
|
|
||||||
if (!tree[stat.host])
|
|
||||||
{
|
|
||||||
tree[stat.host] = {
|
|
||||||
id: stat.host,
|
|
||||||
level: 'host',
|
|
||||||
parent: null,
|
|
||||||
children: [],
|
|
||||||
};
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const node_id in state.config.node_placement||{})
|
|
||||||
{
|
|
||||||
const node_cfg = state.config.node_placement[node_id];
|
|
||||||
if (/^\d+$/.exec(node_id))
|
|
||||||
{
|
|
||||||
node_cfg.level = 'osd';
|
|
||||||
}
|
|
||||||
if (!node_id || !node_cfg.level || !levels[node_cfg.level] ||
|
|
||||||
node_cfg.level === 'osd' && !tree[node_id])
|
|
||||||
{
|
|
||||||
// All nodes must have non-empty IDs and valid levels
|
|
||||||
// OSDs have to actually exist
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
tree[node_id] = tree[node_id] || {};
|
|
||||||
tree[node_id].id = node_id;
|
|
||||||
tree[node_id].level = node_cfg.level;
|
|
||||||
tree[node_id].parent = node_cfg.parent;
|
|
||||||
if (node_cfg.level !== 'osd')
|
|
||||||
{
|
|
||||||
tree[node_id].children = [];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return { up_osds, levels, osd_tree: tree };
|
|
||||||
}
|
|
||||||
|
|
||||||
function make_hier_tree(global_config, tree)
|
|
||||||
{
|
|
||||||
const levels = global_config.placement_levels||{};
|
|
||||||
levels.host = levels.host || 100;
|
|
||||||
levels.osd = levels.osd || 101;
|
|
||||||
tree = { ...tree };
|
|
||||||
for (const node_id in tree)
|
|
||||||
{
|
|
||||||
tree[node_id] = { ...tree[node_id], children: [] };
|
|
||||||
}
|
|
||||||
tree[''] = { children: [] };
|
|
||||||
for (const node_id in tree)
|
|
||||||
{
|
|
||||||
if (node_id === '' || tree[node_id].level === 'osd' && (!tree[node_id].size || tree[node_id].size <= 0))
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
const node_cfg = tree[node_id];
|
|
||||||
const node_level = levels[node_cfg.level] || node_cfg.level;
|
|
||||||
let parent_level = node_cfg.parent && tree[node_cfg.parent] && tree[node_cfg.parent].children
|
|
||||||
&& tree[node_cfg.parent].level;
|
|
||||||
parent_level = parent_level ? (levels[parent_level] || parent_level) : null;
|
|
||||||
// Parent's level must be less than child's; OSDs must be leaves
|
|
||||||
const parent = parent_level && parent_level < node_level ? node_cfg.parent : '';
|
|
||||||
tree[parent].children.push(tree[node_id]);
|
|
||||||
}
|
|
||||||
// Delete empty nodes
|
|
||||||
let deleted = 0;
|
|
||||||
do
|
|
||||||
{
|
|
||||||
deleted = 0;
|
|
||||||
for (const node_id in tree)
|
|
||||||
{
|
|
||||||
if (tree[node_id].level !== 'osd' && (!tree[node_id].children || !tree[node_id].children.length))
|
|
||||||
{
|
|
||||||
const parent = tree[node_id].parent;
|
|
||||||
if (parent)
|
|
||||||
{
|
|
||||||
tree[parent].children = tree[parent].children.filter(c => c != tree[node_id]);
|
|
||||||
}
|
|
||||||
deleted++;
|
|
||||||
delete tree[node_id];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
} while (deleted > 0);
|
|
||||||
return tree;
|
|
||||||
}
|
|
||||||
|
|
||||||
function filter_osds_by_root_node(global_config, pool_tree, root_node)
|
|
||||||
{
|
|
||||||
if (!root_node)
|
|
||||||
{
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
let hier_tree = make_hier_tree(global_config, pool_tree);
|
|
||||||
let included = [ ...(hier_tree[root_node] || {}).children||[] ];
|
|
||||||
for (let i = 0; i < included.length; i++)
|
|
||||||
{
|
|
||||||
if (included[i].children)
|
|
||||||
{
|
|
||||||
included.splice(i+1, 0, ...included[i].children);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
let cur = pool_tree[root_node] || {};
|
|
||||||
while (cur && cur.id)
|
|
||||||
{
|
|
||||||
included.unshift(cur);
|
|
||||||
cur = pool_tree[cur.parent||''];
|
|
||||||
}
|
|
||||||
included = included.reduce((a, c) => { a[c.id||''] = true; return a; }, {});
|
|
||||||
for (const item in pool_tree)
|
|
||||||
{
|
|
||||||
if (!included[item])
|
|
||||||
{
|
|
||||||
delete pool_tree[item];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
function filter_osds_by_tags(orig_tree, tags)
|
|
||||||
{
|
|
||||||
if (!tags)
|
|
||||||
{
|
|
||||||
return;
|
|
||||||
}
|
|
||||||
for (const tag of (tags instanceof Array ? tags : [ tags ]))
|
|
||||||
{
|
|
||||||
for (const osd in orig_tree)
|
|
||||||
{
|
|
||||||
if (orig_tree[osd].level === 'osd' &&
|
|
||||||
(!orig_tree[osd].tags || !orig_tree[osd].tags[tag]))
|
|
||||||
{
|
|
||||||
delete orig_tree[osd];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
function filter_osds_by_block_layout(orig_tree, osd_stats, block_size, bitmap_granularity, immediate_commit)
|
|
||||||
{
|
|
||||||
for (const osd in orig_tree)
|
|
||||||
{
|
|
||||||
if (orig_tree[osd].level === 'osd')
|
|
||||||
{
|
|
||||||
const osd_stat = osd_stats[osd];
|
|
||||||
if (osd_stat && (osd_stat.bs_block_size && osd_stat.bs_block_size != block_size ||
|
|
||||||
osd_stat.bitmap_granularity && osd_stat.bitmap_granularity != bitmap_granularity ||
|
|
||||||
osd_stat.immediate_commit == 'small' && immediate_commit == 'all' ||
|
|
||||||
osd_stat.immediate_commit == 'none' && immediate_commit != 'none'))
|
|
||||||
{
|
|
||||||
delete orig_tree[osd];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
function get_affinity_osds(pool_cfg, up_osds, osd_tree)
|
|
||||||
{
|
|
||||||
let aff_osds = up_osds;
|
|
||||||
if (pool_cfg.primary_affinity_tags)
|
|
||||||
{
|
|
||||||
aff_osds = Object.keys(up_osds).reduce((a, c) => { a[c] = osd_tree[c]; return a; }, {});
|
|
||||||
filter_osds_by_tags(aff_osds, pool_cfg.primary_affinity_tags);
|
|
||||||
for (const osd in aff_osds)
|
|
||||||
{
|
|
||||||
aff_osds[osd] = true;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return aff_osds;
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = {
|
|
||||||
get_osd_tree,
|
|
||||||
make_hier_tree,
|
|
||||||
filter_osds_by_root_node,
|
|
||||||
filter_osds_by_tags,
|
|
||||||
filter_osds_by_block_layout,
|
|
||||||
get_affinity_osds,
|
|
||||||
};
|
|
|
@ -1,24 +1,25 @@
|
||||||
{
|
{
|
||||||
"name": "vitastor-mon",
|
"name": "vitastor-mon",
|
||||||
"version": "1.10.0",
|
"version": "1.6.1",
|
||||||
"description": "Vitastor SDS monitor service",
|
"description": "Vitastor SDS monitor service",
|
||||||
"main": "mon-main.js",
|
"main": "mon-main.js",
|
||||||
"scripts": {
|
"scripts": {
|
||||||
"lint": "eslint *.js lp_optimizer/*.js scripts/*.js"
|
"test": "echo \"Error: no test specified\" && exit 1"
|
||||||
},
|
},
|
||||||
"author": "Vitaliy Filippov",
|
"author": "Vitaliy Filippov",
|
||||||
"license": "UNLICENSED",
|
"license": "UNLICENSED",
|
||||||
"dependencies": {
|
"dependencies": {
|
||||||
"antietcd": "^1.1.0",
|
|
||||||
"sprintf-js": "^1.1.2",
|
"sprintf-js": "^1.1.2",
|
||||||
"ws": "^7.2.5"
|
"ws": "^7.2.5"
|
||||||
},
|
},
|
||||||
"devDependencies": {
|
"devDependencies": {
|
||||||
"eslint": "^8.0.0",
|
"eslint": "^8.0.0",
|
||||||
"eslint-plugin-import": "^2.29.1",
|
|
||||||
"eslint-plugin-node": "^11.1.0"
|
"eslint-plugin-node": "^11.1.0"
|
||||||
},
|
},
|
||||||
"engines": {
|
"engines": {
|
||||||
"node": ">=12.0.0"
|
"node": ">=12.0.0"
|
||||||
|
},
|
||||||
|
"scripts": {
|
||||||
|
"lint": "eslint *.js"
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
267
mon/pg_gen.js
267
mon/pg_gen.js
|
@ -1,267 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const { RuleCombinator } = require('./lp_optimizer/dsl_pgs.js');
|
|
||||||
const { SimpleCombinator, flatten_tree } = require('./lp_optimizer/simple_pgs.js');
|
|
||||||
const { validate_pool_cfg, get_pg_rules } = require('./pool_config.js');
|
|
||||||
const LPOptimizer = require('./lp_optimizer/lp_optimizer.js');
|
|
||||||
const { scale_pg_count } = require('./pg_utils.js');
|
|
||||||
const { make_hier_tree, filter_osds_by_root_node,
|
|
||||||
filter_osds_by_tags, filter_osds_by_block_layout, get_affinity_osds } = require('./osd_tree.js');
|
|
||||||
|
|
||||||
let seed;
|
|
||||||
|
|
||||||
function reset_rng()
|
|
||||||
{
|
|
||||||
seed = 0x5f020e43;
|
|
||||||
}
|
|
||||||
|
|
||||||
function rng()
|
|
||||||
{
|
|
||||||
seed ^= seed << 13;
|
|
||||||
seed ^= seed >> 17;
|
|
||||||
seed ^= seed << 5;
|
|
||||||
return seed + 2147483648;
|
|
||||||
}
|
|
||||||
|
|
||||||
function pick_primary(pool_config, osd_set, up_osds, aff_osds)
|
|
||||||
{
|
|
||||||
let alive_set;
|
|
||||||
if (pool_config.scheme === 'replicated')
|
|
||||||
{
|
|
||||||
// Prefer "affinity" OSDs
|
|
||||||
alive_set = osd_set.filter(osd_num => osd_num && aff_osds[osd_num]);
|
|
||||||
if (!alive_set.length)
|
|
||||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
// Prefer data OSDs for EC because they can actually read something without an additional network hop
|
|
||||||
const pg_data_size = (pool_config.pg_size||0) - (pool_config.parity_chunks||0);
|
|
||||||
alive_set = osd_set.slice(0, pg_data_size).filter(osd_num => osd_num && aff_osds[osd_num]);
|
|
||||||
if (!alive_set.length)
|
|
||||||
alive_set = osd_set.filter(osd_num => osd_num && aff_osds[osd_num]);
|
|
||||||
if (!alive_set.length)
|
|
||||||
{
|
|
||||||
alive_set = osd_set.slice(0, pg_data_size).filter(osd_num => osd_num && up_osds[osd_num]);
|
|
||||||
if (!alive_set.length)
|
|
||||||
alive_set = osd_set.filter(osd_num => osd_num && up_osds[osd_num]);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
if (!alive_set.length)
|
|
||||||
{
|
|
||||||
return 0;
|
|
||||||
}
|
|
||||||
return alive_set[rng() % alive_set.length];
|
|
||||||
}
|
|
||||||
|
|
||||||
function recheck_primary(state, global_config, up_osds, osd_tree)
|
|
||||||
{
|
|
||||||
let new_pg_config;
|
|
||||||
for (const pool_id in state.config.pools)
|
|
||||||
{
|
|
||||||
const pool_cfg = state.config.pools[pool_id];
|
|
||||||
if (!validate_pool_cfg(pool_id, pool_cfg, global_config.placement_levels, false))
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
const aff_osds = get_affinity_osds(pool_cfg, up_osds, osd_tree);
|
|
||||||
reset_rng();
|
|
||||||
for (let pg_num = 1; pg_num <= pool_cfg.pg_count; pg_num++)
|
|
||||||
{
|
|
||||||
if (!state.pg.config.items[pool_id])
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
const pg_cfg = state.pg.config.items[pool_id][pg_num];
|
|
||||||
if (pg_cfg)
|
|
||||||
{
|
|
||||||
const new_primary = pick_primary(state.config.pools[pool_id], pg_cfg.osd_set, up_osds, aff_osds);
|
|
||||||
if (pg_cfg.primary != new_primary)
|
|
||||||
{
|
|
||||||
if (!new_pg_config)
|
|
||||||
{
|
|
||||||
new_pg_config = JSON.parse(JSON.stringify(state.pg.config));
|
|
||||||
}
|
|
||||||
console.log(
|
|
||||||
`Moving pool ${pool_id} (${pool_cfg.name || 'unnamed'}) PG ${pg_num}`+
|
|
||||||
` primary OSD from ${pg_cfg.primary} to ${new_primary}`
|
|
||||||
);
|
|
||||||
new_pg_config.items[pool_id][pg_num].primary = new_primary;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return new_pg_config;
|
|
||||||
}
|
|
||||||
|
|
||||||
function save_new_pgs_txn(save_to, request, state, etcd_prefix, etcd_watch_revision, pool_id, up_osds, osd_tree, prev_pgs, new_pgs, pg_history)
|
|
||||||
{
|
|
||||||
const aff_osds = get_affinity_osds(state.config.pools[pool_id] || {}, up_osds, osd_tree);
|
|
||||||
const pg_items = {};
|
|
||||||
reset_rng();
|
|
||||||
new_pgs.map((osd_set, i) =>
|
|
||||||
{
|
|
||||||
osd_set = osd_set.map(osd_num => osd_num === LPOptimizer.NO_OSD ? 0 : osd_num);
|
|
||||||
pg_items[i+1] = {
|
|
||||||
osd_set,
|
|
||||||
primary: pick_primary(state.config.pools[pool_id], osd_set, up_osds, aff_osds),
|
|
||||||
};
|
|
||||||
if (prev_pgs[i] && prev_pgs[i].join(' ') != osd_set.join(' ') &&
|
|
||||||
prev_pgs[i].filter(osd_num => osd_num).length > 0)
|
|
||||||
{
|
|
||||||
pg_history[i] = pg_history[i] || {};
|
|
||||||
pg_history[i].osd_sets = pg_history[i].osd_sets || [];
|
|
||||||
pg_history[i].osd_sets.push(prev_pgs[i]);
|
|
||||||
}
|
|
||||||
if (pg_history[i] && pg_history[i].osd_sets)
|
|
||||||
{
|
|
||||||
pg_history[i].osd_sets = Object.values(pg_history[i].osd_sets
|
|
||||||
.reduce((a, c) => { a[c.join(' ')] = c; return a; }, {}));
|
|
||||||
}
|
|
||||||
});
|
|
||||||
for (let i = 0; i < new_pgs.length || i < prev_pgs.length; i++)
|
|
||||||
{
|
|
||||||
// FIXME: etcd has max_txn_ops limit, and it's 128 by default
|
|
||||||
// Sooo we probably want to change our storage scheme for PG histories...
|
|
||||||
request.compare.push({
|
|
||||||
key: b64(etcd_prefix+'/pg/history/'+pool_id+'/'+(i+1)),
|
|
||||||
target: 'MOD',
|
|
||||||
mod_revision: ''+etcd_watch_revision,
|
|
||||||
result: 'LESS',
|
|
||||||
});
|
|
||||||
if (pg_history[i])
|
|
||||||
{
|
|
||||||
request.success.push({
|
|
||||||
requestPut: {
|
|
||||||
key: b64(etcd_prefix+'/pg/history/'+pool_id+'/'+(i+1)),
|
|
||||||
value: b64(JSON.stringify(pg_history[i])),
|
|
||||||
},
|
|
||||||
});
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
request.success.push({
|
|
||||||
requestDeleteRange: {
|
|
||||||
key: b64(etcd_prefix+'/pg/history/'+pool_id+'/'+(i+1)),
|
|
||||||
},
|
|
||||||
});
|
|
||||||
}
|
|
||||||
}
|
|
||||||
save_to.items = save_to.items || {};
|
|
||||||
if (!new_pgs.length)
|
|
||||||
{
|
|
||||||
delete save_to.items[pool_id];
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
save_to.items[pool_id] = pg_items;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
async function generate_pool_pgs(state, global_config, pool_id, osd_tree, levels)
|
|
||||||
{
|
|
||||||
const pool_cfg = state.config.pools[pool_id];
|
|
||||||
if (!validate_pool_cfg(pool_id, pool_cfg, global_config.placement_levels, false))
|
|
||||||
{
|
|
||||||
return null;
|
|
||||||
}
|
|
||||||
let pool_tree = { ...osd_tree };
|
|
||||||
filter_osds_by_root_node(global_config, pool_tree, pool_cfg.root_node);
|
|
||||||
filter_osds_by_tags(pool_tree, pool_cfg.osd_tags);
|
|
||||||
filter_osds_by_block_layout(
|
|
||||||
pool_tree,
|
|
||||||
state.osd.stats,
|
|
||||||
pool_cfg.block_size || global_config.block_size || 131072,
|
|
||||||
pool_cfg.bitmap_granularity || global_config.bitmap_granularity || 4096,
|
|
||||||
pool_cfg.immediate_commit || global_config.immediate_commit || 'all'
|
|
||||||
);
|
|
||||||
pool_tree = make_hier_tree(global_config, pool_tree);
|
|
||||||
// First try last_clean_pgs to minimize data movement
|
|
||||||
let prev_pgs = [];
|
|
||||||
for (const pg in ((state.history.last_clean_pgs.items||{})[pool_id]||{}))
|
|
||||||
{
|
|
||||||
prev_pgs[pg-1] = [ ...state.history.last_clean_pgs.items[pool_id][pg].osd_set ];
|
|
||||||
}
|
|
||||||
if (!prev_pgs.length)
|
|
||||||
{
|
|
||||||
// Fall back to pg/config if it's empty
|
|
||||||
for (const pg in ((state.pg.config.items||{})[pool_id]||{}))
|
|
||||||
{
|
|
||||||
prev_pgs[pg-1] = [ ...state.pg.config.items[pool_id][pg].osd_set ];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
const old_pg_count = prev_pgs.length;
|
|
||||||
const optimize_cfg = {
|
|
||||||
osd_weights: Object.values(pool_tree).filter(item => item.level === 'osd').reduce((a, c) => { a[c.id] = c.size; return a; }, {}),
|
|
||||||
combinator: !global_config.use_old_pg_combinator || pool_cfg.level_placement || pool_cfg.raw_placement
|
|
||||||
// new algorithm:
|
|
||||||
? new RuleCombinator(pool_tree, get_pg_rules(pool_id, pool_cfg, global_config.placement_levels), pool_cfg.max_osd_combinations)
|
|
||||||
// old algorithm:
|
|
||||||
: new SimpleCombinator(flatten_tree(pool_tree[''].children, levels, pool_cfg.failure_domain, 'osd'), pool_cfg.pg_size, pool_cfg.max_osd_combinations),
|
|
||||||
pg_count: pool_cfg.pg_count,
|
|
||||||
pg_size: pool_cfg.pg_size,
|
|
||||||
pg_minsize: pool_cfg.pg_minsize,
|
|
||||||
ordered: pool_cfg.scheme != 'replicated',
|
|
||||||
};
|
|
||||||
let optimize_result;
|
|
||||||
// Re-shuffle PGs if pg/config.hash is empty
|
|
||||||
if (old_pg_count > 0 && state.pg.config.hash)
|
|
||||||
{
|
|
||||||
if (prev_pgs.length != pool_cfg.pg_count)
|
|
||||||
{
|
|
||||||
// Scale PG count
|
|
||||||
// Do it even if old_pg_count is already equal to pool_cfg.pg_count,
|
|
||||||
// because last_clean_pgs may still contain the old number of PGs
|
|
||||||
scale_pg_count(prev_pgs, pool_cfg.pg_count);
|
|
||||||
}
|
|
||||||
for (const pg of prev_pgs)
|
|
||||||
{
|
|
||||||
while (pg.length < pool_cfg.pg_size)
|
|
||||||
{
|
|
||||||
pg.push(0);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
optimize_result = await LPOptimizer.optimize_change({
|
|
||||||
prev_pgs,
|
|
||||||
...optimize_cfg,
|
|
||||||
});
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
optimize_result = await LPOptimizer.optimize_initial(optimize_cfg);
|
|
||||||
}
|
|
||||||
console.log(`Pool ${pool_id} (${pool_cfg.name || 'unnamed'}):`);
|
|
||||||
LPOptimizer.print_change_stats(optimize_result);
|
|
||||||
let pg_effsize = pool_cfg.pg_size;
|
|
||||||
for (const pg of optimize_result.int_pgs)
|
|
||||||
{
|
|
||||||
const this_pg_size = pg.filter(osd => osd != LPOptimizer.NO_OSD).length;
|
|
||||||
if (this_pg_size && this_pg_size < pg_effsize)
|
|
||||||
{
|
|
||||||
pg_effsize = this_pg_size;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return {
|
|
||||||
pool_id,
|
|
||||||
pgs: optimize_result.int_pgs,
|
|
||||||
stats: {
|
|
||||||
total_raw_tb: optimize_result.space,
|
|
||||||
pg_real_size: pg_effsize || pool_cfg.pg_size,
|
|
||||||
raw_to_usable: (pg_effsize || pool_cfg.pg_size) / (pool_cfg.scheme === 'replicated'
|
|
||||||
? 1 : (pool_cfg.pg_size - (pool_cfg.parity_chunks||0))),
|
|
||||||
space_efficiency: optimize_result.space/(optimize_result.total_space||1),
|
|
||||||
},
|
|
||||||
};
|
|
||||||
}
|
|
||||||
|
|
||||||
function b64(str)
|
|
||||||
{
|
|
||||||
return Buffer.from(str).toString('base64');
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = {
|
|
||||||
recheck_primary,
|
|
||||||
save_new_pgs_txn,
|
|
||||||
generate_pool_pgs,
|
|
||||||
};
|
|
|
@ -1,169 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const { parse_level_indexes, parse_pg_dsl } = require('./lp_optimizer/dsl_pgs.js');
|
|
||||||
|
|
||||||
function validate_pool_cfg(pool_id, pool_cfg, placement_levels, warn)
|
|
||||||
{
|
|
||||||
pool_cfg.pg_size = Math.floor(pool_cfg.pg_size);
|
|
||||||
pool_cfg.pg_minsize = Math.floor(pool_cfg.pg_minsize);
|
|
||||||
pool_cfg.parity_chunks = Math.floor(pool_cfg.parity_chunks) || undefined;
|
|
||||||
pool_cfg.pg_count = Math.floor(pool_cfg.pg_count);
|
|
||||||
pool_cfg.max_osd_combinations = Math.floor(pool_cfg.max_osd_combinations) || 10000;
|
|
||||||
if (!/^[1-9]\d*$/.exec(''+pool_id))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool ID '+pool_id+' is invalid');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.scheme !== 'xor' && pool_cfg.scheme !== 'replicated' &&
|
|
||||||
pool_cfg.scheme !== 'ec' && pool_cfg.scheme !== 'jerasure')
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid coding scheme (one of "xor", "replicated", "ec" and "jerasure" required)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (!pool_cfg.pg_size || pool_cfg.pg_size < 1 || pool_cfg.pg_size > 256 ||
|
|
||||||
pool_cfg.scheme !== 'replicated' && pool_cfg.pg_size < 3)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid pg_size');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (!pool_cfg.pg_minsize || pool_cfg.pg_minsize < 1 || pool_cfg.pg_minsize > pool_cfg.pg_size ||
|
|
||||||
pool_cfg.scheme === 'xor' && pool_cfg.pg_minsize < (pool_cfg.pg_size - 1))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid pg_minsize');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.scheme === 'xor' && pool_cfg.parity_chunks != 0 && pool_cfg.parity_chunks != 1)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid parity_chunks (must be 1)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if ((pool_cfg.scheme === 'ec' || pool_cfg.scheme === 'jerasure') &&
|
|
||||||
(pool_cfg.parity_chunks < 1 || pool_cfg.parity_chunks > pool_cfg.pg_size-2))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid parity_chunks (must be between 1 and pg_size-2)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (!pool_cfg.pg_count || pool_cfg.pg_count < 1)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid pg_count');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (!pool_cfg.name)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has empty name');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.max_osd_combinations < 100)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid max_osd_combinations (must be at least 100)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.root_node && typeof(pool_cfg.root_node) != 'string')
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid root_node (must be a string)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.osd_tags && typeof(pool_cfg.osd_tags) != 'string' &&
|
|
||||||
(!(pool_cfg.osd_tags instanceof Array) || pool_cfg.osd_tags.filter(t => typeof t != 'string').length > 0))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid osd_tags (must be a string or array of strings)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (pool_cfg.primary_affinity_tags && typeof(pool_cfg.primary_affinity_tags) != 'string' &&
|
|
||||||
(!(pool_cfg.primary_affinity_tags instanceof Array) || pool_cfg.primary_affinity_tags.filter(t => typeof t != 'string').length > 0))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' has invalid primary_affinity_tags (must be a string or array of strings)');
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
if (!get_pg_rules(pool_id, pool_cfg, placement_levels, true))
|
|
||||||
{
|
|
||||||
return false;
|
|
||||||
}
|
|
||||||
return true;
|
|
||||||
}
|
|
||||||
|
|
||||||
function get_pg_rules(pool_id, pool_cfg, placement_levels, warn)
|
|
||||||
{
|
|
||||||
if (pool_cfg.level_placement)
|
|
||||||
{
|
|
||||||
const pg_size = (0|pool_cfg.pg_size);
|
|
||||||
let rules = pool_cfg.level_placement;
|
|
||||||
if (typeof rules === 'string')
|
|
||||||
{
|
|
||||||
rules = rules.split(/\s+/).map(s => s.split(/=/, 2)).reduce((a, c) => { a[c[0]] = c[1]; return a; }, {});
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
rules = { ...rules };
|
|
||||||
}
|
|
||||||
// Always add failure_domain to prevent rules from being totally incorrect
|
|
||||||
const all_diff = [];
|
|
||||||
for (let i = 1; i <= pg_size; i++)
|
|
||||||
{
|
|
||||||
all_diff.push(i);
|
|
||||||
}
|
|
||||||
rules[pool_cfg.failure_domain || 'host'] = all_diff;
|
|
||||||
placement_levels = placement_levels||{};
|
|
||||||
placement_levels.host = placement_levels.host || 100;
|
|
||||||
placement_levels.osd = placement_levels.osd || 101;
|
|
||||||
for (const k in rules)
|
|
||||||
{
|
|
||||||
if (!placement_levels[k] || typeof rules[k] !== 'string' &&
|
|
||||||
(!(rules[k] instanceof Array) ||
|
|
||||||
rules[k].filter(s => typeof s !== 'string' && typeof s !== 'number').length > 0))
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' configuration is invalid: level_placement should be { [level]: string | (string|number)[] }');
|
|
||||||
return null;
|
|
||||||
}
|
|
||||||
else if (rules[k].length != pg_size)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' configuration is invalid: values in level_placement should contain exactly pg_size ('+pg_size+') items');
|
|
||||||
return null;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return parse_level_indexes(rules);
|
|
||||||
}
|
|
||||||
else if (typeof pool_cfg.raw_placement === 'string')
|
|
||||||
{
|
|
||||||
try
|
|
||||||
{
|
|
||||||
return parse_pg_dsl(pool_cfg.raw_placement);
|
|
||||||
}
|
|
||||||
catch (e)
|
|
||||||
{
|
|
||||||
if (warn)
|
|
||||||
console.log('Pool '+pool_id+' configuration is invalid: invalid raw_placement: '+e.message);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
let rules = [ [] ];
|
|
||||||
let prev = [ 1 ];
|
|
||||||
for (let i = 1; i < pool_cfg.pg_size; i++)
|
|
||||||
{
|
|
||||||
rules.push([ [ pool_cfg.failure_domain||'host', '!=', prev ] ]);
|
|
||||||
prev = [ ...prev, i+1 ];
|
|
||||||
}
|
|
||||||
return rules;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = {
|
|
||||||
validate_pool_cfg,
|
|
||||||
get_pg_rules,
|
|
||||||
};
|
|
|
@ -1,220 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
const metric_help =
|
|
||||||
`# HELP vitastor_object_bytes Total size of objects in cluster in bytes
|
|
||||||
# TYPE vitastor_object_bytes gauge
|
|
||||||
# HELP vitastor_object_count Total number of objects in cluster
|
|
||||||
# TYPE vitastor_object_count gauge
|
|
||||||
# HELP vitastor_stat_count Total operation count
|
|
||||||
# TYPE vitastor_stat_count counter
|
|
||||||
# HELP vitastor_stat_usec Total operation latency in usec
|
|
||||||
# TYPE vitastor_stat_usec counter
|
|
||||||
# HELP vitastor_stat_bytes Total operation size in bytes
|
|
||||||
# HELP vitastor_stat_bytes counter
|
|
||||||
|
|
||||||
# HELP vitastor_image_raw_used Image raw used size in bytes
|
|
||||||
# TYPE vitastor_image_raw_used counter
|
|
||||||
# HELP vitastor_image_stat_count Per-image total operation count
|
|
||||||
# TYPE vitastor_image_stat_count counter
|
|
||||||
# HELP vitastor_image_stat_usec Per-image total operation latency
|
|
||||||
# TYPE vitastor_image_stat_usec counter
|
|
||||||
# HELP vitastor_image_stat_bytes Per-image total operation size in bytes
|
|
||||||
# TYPE vitastor_image_stat_bytes counter
|
|
||||||
|
|
||||||
# HELP vitastor_osd_status OSD up/down status
|
|
||||||
# TYPE vitastor_osd_status gauge
|
|
||||||
# HELP vitastor_osd_size_bytes OSD total space in bytes
|
|
||||||
# TYPE vitastor_osd_size_bytes gauge
|
|
||||||
# HELP vitastor_osd_free_bytes OSD free space in bytes
|
|
||||||
# TYPE vitastor_osd_free_bytes gauge
|
|
||||||
# HELP vitastor_osd_stat_count Per-image total operation count
|
|
||||||
# TYPE vitastor_osd_stat_count counter
|
|
||||||
# HELP vitastor_osd_stat_usec Per-image total operation latency
|
|
||||||
# TYPE vitastor_osd_stat_usec counter
|
|
||||||
# HELP vitastor_osd_stat_bytes Per-image total operation size in bytes
|
|
||||||
# TYPE vitastor_osd_stat_bytes counter
|
|
||||||
|
|
||||||
# HELP vitastor_monitor_info Monitor info, 1 is master, 0 is standby
|
|
||||||
# TYPE vitastor_monitor_info gauge
|
|
||||||
|
|
||||||
# HELP vitastor_pool_info Pool configuration (in labels)
|
|
||||||
# TYPE vitastor_pool_info gauge
|
|
||||||
# HELP vitastor_pool_status Pool up/down status
|
|
||||||
# TYPE vitastor_pool_status gauge
|
|
||||||
# HELP vitastor_pool_raw_to_usable Raw to usable space ratio
|
|
||||||
# TYPE vitastor_pool_raw_to_usable gauge
|
|
||||||
# HELP vitastor_pool_space_efficiency Pool space usage efficiency
|
|
||||||
# TYPE vitastor_pool_space_efficiency gauge
|
|
||||||
# HELP vitastor_pool_total_raw_tb Total raw space in pool in TB
|
|
||||||
# TYPE vitastor_pool_total_raw_tb gauge
|
|
||||||
# HELP vitastor_pool_used_raw_tb Used raw space in pool in TB
|
|
||||||
# TYPE vitastor_pool_used_raw_tb gauge
|
|
||||||
# HELP vitastor_pg_count PG counts by state
|
|
||||||
# HELP vitastor_pg_count gauge
|
|
||||||
|
|
||||||
`;
|
|
||||||
|
|
||||||
function export_prometheus_metrics(st)
|
|
||||||
{
|
|
||||||
let res = metric_help;
|
|
||||||
|
|
||||||
// Global statistics
|
|
||||||
|
|
||||||
for (const k in st.stats.object_bytes)
|
|
||||||
{
|
|
||||||
res += `vitastor_object_bytes{object_type="${k}"} ${st.stats.object_bytes[k]}\n`;
|
|
||||||
}
|
|
||||||
|
|
||||||
for (const k in st.stats.object_counts)
|
|
||||||
{
|
|
||||||
res += `vitastor_object_count{object_type="${k}"} ${st.stats.object_counts[k]}\n`;
|
|
||||||
}
|
|
||||||
|
|
||||||
for (const typ of [ 'op', 'subop', 'recovery' ])
|
|
||||||
{
|
|
||||||
for (const op in st.stats[typ+"_stats"]||{})
|
|
||||||
{
|
|
||||||
const op_stat = st.stats[typ+"_stats"][op];
|
|
||||||
for (const key of [ 'count', 'usec', 'bytes' ])
|
|
||||||
{
|
|
||||||
res += `vitastor_stat_${key}{op="${op}",op_type="${typ}"} ${op_stat[key]||0}\n`;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
// Per-image statistics
|
|
||||||
|
|
||||||
for (const pool in st.inode.stats)
|
|
||||||
{
|
|
||||||
for (const inode in st.inode.stats[pool])
|
|
||||||
{
|
|
||||||
const ist = st.inode.stats[pool][inode];
|
|
||||||
const inode_name = ((st.config.inode[pool]||{})[inode]||{}).name||'';
|
|
||||||
const inode_label = `image_name="${addslashes(inode_name)}",inode_num="${inode}",pool_id="${pool}"`;
|
|
||||||
res += `vitastor_image_raw_used{${inode_label}} ${ist.raw_used||0}\n`;
|
|
||||||
for (const op of [ 'read', 'write', 'delete' ])
|
|
||||||
{
|
|
||||||
for (const k of [ 'count', 'usec', 'bytes' ])
|
|
||||||
{
|
|
||||||
if (ist[op])
|
|
||||||
{
|
|
||||||
res += `vitastor_image_stat_${k}{${inode_label},op="${op}"} ${ist[op][k]||0}\n`;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
// Per-OSD statistics
|
|
||||||
|
|
||||||
for (const osd in st.osd.stats)
|
|
||||||
{
|
|
||||||
const osd_stat = st.osd.stats[osd];
|
|
||||||
const up = st.osd.state[osd] && st.osd.state[osd].state == 'up' ? 1 : 0;
|
|
||||||
res += `vitastor_osd_status{host="${addslashes(osd_stat.host)}",osd_num="${osd}"} ${up}\n`;
|
|
||||||
res += `vitastor_osd_size_bytes{osd_num="${osd}"} ${osd_stat.size||0}\n`;
|
|
||||||
res += `vitastor_osd_free_bytes{osd_num="${osd}"} ${osd_stat.free||0}\n`;
|
|
||||||
for (const op in osd_stat.op_stats)
|
|
||||||
{
|
|
||||||
const ist = osd_stat.op_stats[op];
|
|
||||||
for (const k of [ 'count', 'usec', 'bytes' ])
|
|
||||||
{
|
|
||||||
res += `vitastor_osd_stat_${k}{osd_num="${osd}",op="${op}",op_type="op"} ${ist[k]||0}\n`;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const op in osd_stat.subop_stats)
|
|
||||||
{
|
|
||||||
const ist = osd_stat.subop_stats[op];
|
|
||||||
for (const k of [ 'count', 'usec', 'bytes' ])
|
|
||||||
{
|
|
||||||
res += `vitastor_osd_stat_${k}{osd_num="${osd}",op="${op}",op_type="subop"} ${ist[k]||0}\n`;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
// Monitor statistics
|
|
||||||
|
|
||||||
for (const mon_id in st.mon.member)
|
|
||||||
{
|
|
||||||
const mon = st.mon.member[mon_id];
|
|
||||||
const master = st.mon.master && st.mon.master.id == mon_id ? 1 : 0;
|
|
||||||
const ip = (mon.ip instanceof Array ? mon.ip[0] : mon.ip) || '';
|
|
||||||
res += `vitastor_monitor_info{monitor_hostname="${addslashes(mon.hostname)}",monitor_id="${mon_id}",monitor_ip="${addslashes(ip)}"} ${master}\n`;
|
|
||||||
}
|
|
||||||
|
|
||||||
// Per-pool statistics
|
|
||||||
|
|
||||||
for (const pool_id in st.config.pools)
|
|
||||||
{
|
|
||||||
const pool_cfg = st.config.pools[pool_id];
|
|
||||||
const pool_label = `pool_id="${pool_id}",pool_name="${addslashes(pool_cfg.name)}"`;
|
|
||||||
const pool_stat = st.pool.stats[pool_id];
|
|
||||||
res += `vitastor_pool_info{${pool_label}`+
|
|
||||||
`,pool_scheme="${addslashes(pool_cfg.scheme)}"`+
|
|
||||||
`,pg_size="${pool_cfg.pg_size||0}",pg_minsize="${pool_cfg.pg_minsize||0}"`+
|
|
||||||
`,parity_chunks="${pool_cfg.parity_chunks||0}",pg_count="${pool_cfg.pg_count||0}"`+
|
|
||||||
`,failure_domain="${addslashes(pool_cfg.failure_domain)}"`+
|
|
||||||
`} 1\n`;
|
|
||||||
if (!pool_stat)
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
res += `vitastor_pool_raw_to_usable{${pool_label}} ${pool_stat.raw_to_usable||0}\n`;
|
|
||||||
res += `vitastor_pool_space_efficiency{${pool_label}} ${pool_stat.space_efficiency||0}\n`;
|
|
||||||
res += `vitastor_pool_total_raw_tb{${pool_label}} ${pool_stat.total_raw_tb||0}\n`;
|
|
||||||
res += `vitastor_pool_used_raw_tb{${pool_label}} ${pool_stat.used_raw_tb||0}\n`;
|
|
||||||
|
|
||||||
// PG states and pool up/down status
|
|
||||||
const real_pg_count = (Object.keys(((st.pg.config||{}).items||{})[pool_id]||{}).length) || (0|pool_cfg.pg_count);
|
|
||||||
const per_state = {
|
|
||||||
active: 0,
|
|
||||||
starting: 0,
|
|
||||||
peering: 0,
|
|
||||||
incomplete: 0,
|
|
||||||
repeering: 0,
|
|
||||||
stopping: 0,
|
|
||||||
offline: 0,
|
|
||||||
degraded: 0,
|
|
||||||
has_inconsistent: 0,
|
|
||||||
has_corrupted: 0,
|
|
||||||
has_incomplete: 0,
|
|
||||||
has_degraded: 0,
|
|
||||||
has_misplaced: 0,
|
|
||||||
has_unclean: 0,
|
|
||||||
has_invalid: 0,
|
|
||||||
left_on_dead: 0,
|
|
||||||
scrubbing: 0,
|
|
||||||
};
|
|
||||||
const pool_pg_states = st.pg.state[pool_id] || {};
|
|
||||||
for (let i = 1; i <= real_pg_count; i++)
|
|
||||||
{
|
|
||||||
if (!pool_pg_states[i])
|
|
||||||
{
|
|
||||||
per_state['offline'] = 1 + (per_state['offline']|0);
|
|
||||||
}
|
|
||||||
else
|
|
||||||
{
|
|
||||||
for (const st_name of pool_pg_states[i].state)
|
|
||||||
{
|
|
||||||
per_state[st_name] = 1 + (per_state[st_name]|0);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const st_name in per_state)
|
|
||||||
{
|
|
||||||
res += `vitastor_pg_count{pg_state="${st_name}",${pool_label}} ${per_state[st_name]}\n`;
|
|
||||||
}
|
|
||||||
const pool_active = per_state['active'] >= real_pg_count ? 1 : 0;
|
|
||||||
res += `vitastor_pool_status{${pool_label}} ${pool_active}\n`;
|
|
||||||
}
|
|
||||||
|
|
||||||
return res;
|
|
||||||
}
|
|
||||||
|
|
||||||
function addslashes(str)
|
|
||||||
{
|
|
||||||
return ((str||'')+'').replace(/(["\n\\])/g, "\\$1"); // escape " \n \
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = { export_prometheus_metrics };
|
|
File diff suppressed because it is too large
Load Diff
329
mon/stats.js
329
mon/stats.js
|
@ -1,329 +0,0 @@
|
||||||
// Copyright (c) Vitaliy Filippov, 2019+
|
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
|
||||||
|
|
||||||
function derive_osd_stats(st, prev, prev_diff)
|
|
||||||
{
|
|
||||||
const diff = prev_diff || { op_stats: {}, subop_stats: {}, recovery_stats: {}, inode_stats: {} };
|
|
||||||
if (!st || !st.time || !prev || !prev.time || prev.time >= st.time)
|
|
||||||
{
|
|
||||||
return diff;
|
|
||||||
}
|
|
||||||
const timediff = BigInt(st.time*1000 - prev.time*1000);
|
|
||||||
for (const op in st.op_stats||{})
|
|
||||||
{
|
|
||||||
const pr = prev && prev.op_stats && prev.op_stats[op];
|
|
||||||
let c = st.op_stats[op];
|
|
||||||
c = { bytes: BigInt(c.bytes||0), usec: BigInt(c.usec||0), count: BigInt(c.count||0) };
|
|
||||||
const b = c.bytes - BigInt(pr && pr.bytes||0);
|
|
||||||
const us = c.usec - BigInt(pr && pr.usec||0);
|
|
||||||
const n = c.count - BigInt(pr && pr.count||0);
|
|
||||||
diff.op_stats[op] = { ...c, bps: n > 0 ? b*1000n/timediff : 0n, iops: n > 0 ? n*1000n/timediff : 0n, lat: n > 0 ? us/n : 0n };
|
|
||||||
}
|
|
||||||
for (const op in st.subop_stats||{})
|
|
||||||
{
|
|
||||||
const pr = prev && prev.subop_stats && prev.subop_stats[op];
|
|
||||||
let c = st.subop_stats[op];
|
|
||||||
c = { usec: BigInt(c.usec||0), count: BigInt(c.count||0) };
|
|
||||||
const us = c.usec - BigInt(pr && pr.usec||0);
|
|
||||||
const n = c.count - BigInt(pr && pr.count||0);
|
|
||||||
diff.subop_stats[op] = { ...c, iops: n > 0 ? n*1000n/timediff : 0n, lat: n > 0 ? us/n : 0n };
|
|
||||||
}
|
|
||||||
for (const op in st.recovery_stats||{})
|
|
||||||
{
|
|
||||||
const pr = prev && prev.recovery_stats && prev.recovery_stats[op];
|
|
||||||
let c = st.recovery_stats[op];
|
|
||||||
c = { bytes: BigInt(c.bytes||0), count: BigInt(c.count||0) };
|
|
||||||
const b = c.bytes - BigInt(pr && pr.bytes||0);
|
|
||||||
const n = c.count - BigInt(pr && pr.count||0);
|
|
||||||
diff.recovery_stats[op] = { ...c, bps: n > 0 ? b*1000n/timediff : 0n, iops: n > 0 ? n*1000n/timediff : 0n };
|
|
||||||
}
|
|
||||||
for (const pool_id in st.inode_stats||{})
|
|
||||||
{
|
|
||||||
diff.inode_stats[pool_id] = {};
|
|
||||||
for (const inode_num in st.inode_stats[pool_id])
|
|
||||||
{
|
|
||||||
const inode_diff = diff.inode_stats[pool_id][inode_num] = {};
|
|
||||||
for (const op of [ 'read', 'write', 'delete' ])
|
|
||||||
{
|
|
||||||
const c = st.inode_stats[pool_id][inode_num][op];
|
|
||||||
const pr = prev && prev.inode_stats && prev.inode_stats[pool_id] &&
|
|
||||||
prev.inode_stats[pool_id][inode_num] && prev.inode_stats[pool_id][inode_num][op];
|
|
||||||
const n = BigInt(c.count||0) - BigInt(pr && pr.count||0);
|
|
||||||
inode_diff[op] = {
|
|
||||||
bps: n > 0 ? (BigInt(c.bytes||0) - BigInt(pr && pr.bytes||0))*1000n/timediff : 0n,
|
|
||||||
iops: n > 0 ? n*1000n/timediff : 0n,
|
|
||||||
lat: n > 0 ? (BigInt(c.usec||0) - BigInt(pr && pr.usec||0))/n : 0n,
|
|
||||||
};
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return diff;
|
|
||||||
}
|
|
||||||
|
|
||||||
// sum_op_stats(this.state.osd, this.prev_stats)
|
|
||||||
function sum_op_stats(all_osd, prev_stats)
|
|
||||||
{
|
|
||||||
for (const osd in all_osd.stats)
|
|
||||||
{
|
|
||||||
const cur = { ...all_osd.stats[osd], inode_stats: all_osd.inodestats[osd]||{} };
|
|
||||||
prev_stats.osd_diff[osd] = derive_osd_stats(
|
|
||||||
cur, prev_stats.osd_stats[osd], prev_stats.osd_diff[osd]
|
|
||||||
);
|
|
||||||
prev_stats.osd_stats[osd] = cur;
|
|
||||||
}
|
|
||||||
const sum_diff = { op_stats: {}, subop_stats: {}, recovery_stats: { degraded: {}, misplaced: {} } };
|
|
||||||
// Sum derived values instead of deriving summed
|
|
||||||
for (const osd in all_osd.state)
|
|
||||||
{
|
|
||||||
const derived = prev_stats.osd_diff[osd];
|
|
||||||
if (!all_osd.state[osd] || !derived)
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
for (const type in sum_diff)
|
|
||||||
{
|
|
||||||
for (const op in derived[type]||{})
|
|
||||||
{
|
|
||||||
for (const k in derived[type][op])
|
|
||||||
{
|
|
||||||
sum_diff[type][op] = sum_diff[type][op] || {};
|
|
||||||
sum_diff[type][op][k] = (sum_diff[type][op][k] || 0n) + derived[type][op][k];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return sum_diff;
|
|
||||||
}
|
|
||||||
|
|
||||||
// sum_object_counts(this.state, this.config)
|
|
||||||
function sum_object_counts(state, global_config)
|
|
||||||
{
|
|
||||||
const object_counts = { object: 0n, clean: 0n, misplaced: 0n, degraded: 0n, incomplete: 0n };
|
|
||||||
const object_bytes = { object: 0n, clean: 0n, misplaced: 0n, degraded: 0n, incomplete: 0n };
|
|
||||||
let pgstats = state.pgstats;
|
|
||||||
if (state.pg.stats)
|
|
||||||
{
|
|
||||||
// Merge with old stats for seamless transition to new stats
|
|
||||||
for (const pool_id in state.pg.stats)
|
|
||||||
{
|
|
||||||
pgstats[pool_id] = { ...(state.pg.stats[pool_id] || {}), ...(pgstats[pool_id] || {}) };
|
|
||||||
}
|
|
||||||
}
|
|
||||||
const pool_per_osd = {};
|
|
||||||
const clean_per_osd = {};
|
|
||||||
for (const pool_id in pgstats)
|
|
||||||
{
|
|
||||||
let object_size = 0;
|
|
||||||
for (const osd_num of pgstats[pool_id].write_osd_set||[])
|
|
||||||
{
|
|
||||||
if (osd_num && state.osd.stats[osd_num] && state.osd.stats[osd_num].block_size)
|
|
||||||
{
|
|
||||||
object_size = state.osd.stats[osd_num].block_size;
|
|
||||||
break;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
const pool_cfg = (state.config.pools[pool_id]||{});
|
|
||||||
if (!object_size)
|
|
||||||
{
|
|
||||||
object_size = pool_cfg.block_size || global_config.block_size || 131072;
|
|
||||||
}
|
|
||||||
if (pool_cfg.scheme !== 'replicated')
|
|
||||||
{
|
|
||||||
object_size *= ((pool_cfg.pg_size||0) - (pool_cfg.parity_chunks||0));
|
|
||||||
}
|
|
||||||
object_size = BigInt(object_size);
|
|
||||||
for (const pg_num in pgstats[pool_id])
|
|
||||||
{
|
|
||||||
const st = pgstats[pool_id][pg_num];
|
|
||||||
if (st)
|
|
||||||
{
|
|
||||||
for (const k in object_counts)
|
|
||||||
{
|
|
||||||
if (st[k+'_count'])
|
|
||||||
{
|
|
||||||
object_counts[k] += BigInt(st[k+'_count']);
|
|
||||||
object_bytes[k] += BigInt(st[k+'_count']) * object_size;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
if (st.object_count)
|
|
||||||
{
|
|
||||||
for (const pg_osd of (((state.pg.config.items||{})[pool_id]||{})[pg_num]||{}).osd_set||[])
|
|
||||||
{
|
|
||||||
if (!(pg_osd in clean_per_osd))
|
|
||||||
{
|
|
||||||
clean_per_osd[pg_osd] = 0n;
|
|
||||||
}
|
|
||||||
clean_per_osd[pg_osd] += BigInt(st.object_count);
|
|
||||||
pool_per_osd[pg_osd] = pool_per_osd[pg_osd]||{};
|
|
||||||
pool_per_osd[pg_osd][pool_id] = true;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
// If clean_per_osd[osd] is larger than osd capacity then it will fill up during rebalance
|
|
||||||
let backfillfull_pools = {};
|
|
||||||
let backfillfull_osds = {};
|
|
||||||
for (const osd in clean_per_osd)
|
|
||||||
{
|
|
||||||
const st = state.osd.stats[osd];
|
|
||||||
if (!st || !st.size || !st.data_block_size)
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
let cap = BigInt(st.size)/BigInt(st.data_block_size);
|
|
||||||
cap = cap * BigInt((global_config.osd_backfillfull_ratio||0.99)*1000000) / 1000000n;
|
|
||||||
if (cap < clean_per_osd[osd])
|
|
||||||
{
|
|
||||||
backfillfull_osds[osd] = { cap: BigInt(st.size), clean: clean_per_osd[osd]*BigInt(st.data_block_size) };
|
|
||||||
for (const pool_id in pool_per_osd[osd])
|
|
||||||
{
|
|
||||||
backfillfull_pools[pool_id] = true;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
backfillfull_pools = Object.keys(backfillfull_pools).sort();
|
|
||||||
return { object_counts, object_bytes, backfillfull_pools, backfillfull_osds };
|
|
||||||
}
|
|
||||||
|
|
||||||
// sum_inode_stats(this.state, this.prev_stats)
|
|
||||||
function sum_inode_stats(state, prev_stats)
|
|
||||||
{
|
|
||||||
const inode_stats = {};
|
|
||||||
const inode_stub = () => ({
|
|
||||||
raw_used: 0n,
|
|
||||||
read: { count: 0n, usec: 0n, bytes: 0n, bps: 0n, iops: 0n, lat: 0n },
|
|
||||||
write: { count: 0n, usec: 0n, bytes: 0n, bps: 0n, iops: 0n, lat: 0n },
|
|
||||||
delete: { count: 0n, usec: 0n, bytes: 0n, bps: 0n, iops: 0n, lat: 0n },
|
|
||||||
});
|
|
||||||
const seen_pools = {};
|
|
||||||
for (const pool_id in state.config.pools)
|
|
||||||
{
|
|
||||||
seen_pools[pool_id] = true;
|
|
||||||
state.pool.stats[pool_id] = state.pool.stats[pool_id] || {};
|
|
||||||
state.pool.stats[pool_id].used_raw_tb = 0n;
|
|
||||||
}
|
|
||||||
for (const osd_num in state.osd.space)
|
|
||||||
{
|
|
||||||
for (const pool_id in state.osd.space[osd_num])
|
|
||||||
{
|
|
||||||
state.pool.stats[pool_id] = state.pool.stats[pool_id] || {};
|
|
||||||
if (!seen_pools[pool_id])
|
|
||||||
{
|
|
||||||
state.pool.stats[pool_id].used_raw_tb = 0n;
|
|
||||||
seen_pools[pool_id] = true;
|
|
||||||
}
|
|
||||||
inode_stats[pool_id] = inode_stats[pool_id] || {};
|
|
||||||
for (const inode_num in state.osd.space[osd_num][pool_id])
|
|
||||||
{
|
|
||||||
const u = BigInt(state.osd.space[osd_num][pool_id][inode_num]||0);
|
|
||||||
if (inode_num)
|
|
||||||
{
|
|
||||||
inode_stats[pool_id][inode_num] = inode_stats[pool_id][inode_num] || inode_stub();
|
|
||||||
inode_stats[pool_id][inode_num].raw_used += u;
|
|
||||||
}
|
|
||||||
state.pool.stats[pool_id].used_raw_tb += u;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const pool_id in seen_pools)
|
|
||||||
{
|
|
||||||
const used = state.pool.stats[pool_id].used_raw_tb;
|
|
||||||
state.pool.stats[pool_id].used_raw_tb = Number(used)/1024/1024/1024/1024;
|
|
||||||
}
|
|
||||||
for (const osd_num in state.osd.state)
|
|
||||||
{
|
|
||||||
const ist = state.osd.inodestats[osd_num];
|
|
||||||
if (!ist || !state.osd.state[osd_num])
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
for (const pool_id in ist)
|
|
||||||
{
|
|
||||||
inode_stats[pool_id] = inode_stats[pool_id] || {};
|
|
||||||
for (const inode_num in ist[pool_id])
|
|
||||||
{
|
|
||||||
inode_stats[pool_id][inode_num] = inode_stats[pool_id][inode_num] || inode_stub();
|
|
||||||
for (const op of [ 'read', 'write', 'delete' ])
|
|
||||||
{
|
|
||||||
inode_stats[pool_id][inode_num][op].count += BigInt(ist[pool_id][inode_num][op].count||0);
|
|
||||||
inode_stats[pool_id][inode_num][op].usec += BigInt(ist[pool_id][inode_num][op].usec||0);
|
|
||||||
inode_stats[pool_id][inode_num][op].bytes += BigInt(ist[pool_id][inode_num][op].bytes||0);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const osd in state.osd.state)
|
|
||||||
{
|
|
||||||
const osd_diff = prev_stats.osd_diff[osd];
|
|
||||||
if (!osd_diff || !state.osd.state[osd])
|
|
||||||
{
|
|
||||||
continue;
|
|
||||||
}
|
|
||||||
for (const pool_id in osd_diff.inode_stats)
|
|
||||||
{
|
|
||||||
for (const inode_num in prev_stats.osd_diff[osd].inode_stats[pool_id])
|
|
||||||
{
|
|
||||||
inode_stats[pool_id][inode_num] = inode_stats[pool_id][inode_num] || inode_stub();
|
|
||||||
for (const op of [ 'read', 'write', 'delete' ])
|
|
||||||
{
|
|
||||||
const op_diff = prev_stats.osd_diff[osd].inode_stats[pool_id][inode_num][op] || {};
|
|
||||||
const op_st = inode_stats[pool_id][inode_num][op];
|
|
||||||
op_st.bps += op_diff.bps;
|
|
||||||
op_st.iops += op_diff.iops;
|
|
||||||
op_st.lat += op_diff.lat;
|
|
||||||
op_st.n_osd = (op_st.n_osd || 0) + 1;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
for (const pool_id in inode_stats)
|
|
||||||
{
|
|
||||||
for (const inode_num in inode_stats[pool_id])
|
|
||||||
{
|
|
||||||
let nonzero = inode_stats[pool_id][inode_num].raw_used > 0;
|
|
||||||
for (const op of [ 'read', 'write', 'delete' ])
|
|
||||||
{
|
|
||||||
const op_st = inode_stats[pool_id][inode_num][op];
|
|
||||||
if (op_st.n_osd)
|
|
||||||
{
|
|
||||||
op_st.lat /= BigInt(op_st.n_osd);
|
|
||||||
delete op_st.n_osd;
|
|
||||||
}
|
|
||||||
if (op_st.bps > 0 || op_st.iops > 0)
|
|
||||||
nonzero = true;
|
|
||||||
}
|
|
||||||
if (!nonzero && (!state.config.inode[pool_id] || !state.config.inode[pool_id][inode_num]))
|
|
||||||
{
|
|
||||||
// Deleted inode (no data, no I/O, no config)
|
|
||||||
delete inode_stats[pool_id][inode_num];
|
|
||||||
}
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return { inode_stats, seen_pools };
|
|
||||||
}
|
|
||||||
|
|
||||||
function serialize_bigints(obj)
|
|
||||||
{
|
|
||||||
obj = { ...obj };
|
|
||||||
for (const k in obj)
|
|
||||||
{
|
|
||||||
if (typeof obj[k] == 'bigint')
|
|
||||||
{
|
|
||||||
obj[k] = ''+obj[k];
|
|
||||||
}
|
|
||||||
else if (typeof obj[k] == 'object')
|
|
||||||
{
|
|
||||||
obj[k] = serialize_bigints(obj[k]);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
return obj;
|
|
||||||
}
|
|
||||||
|
|
||||||
module.exports = {
|
|
||||||
derive_osd_stats,
|
|
||||||
sum_op_stats,
|
|
||||||
sum_object_counts,
|
|
||||||
sum_inode_stats,
|
|
||||||
serialize_bigints,
|
|
||||||
};
|
|
|
@ -8,7 +8,7 @@
|
||||||
// But we support this case with the "parity_space" parameter in optimize_initial()/optimize_change().
|
// But we support this case with the "parity_space" parameter in optimize_initial()/optimize_change().
|
||||||
|
|
||||||
const { SimpleCombinator } = require('./simple_pgs.js');
|
const { SimpleCombinator } = require('./simple_pgs.js');
|
||||||
const LPOptimizer = require('./lp_optimizer.js');
|
const LPOptimizer = require('./lp-optimizer.js');
|
||||||
|
|
||||||
const osd_tree = {
|
const osd_tree = {
|
||||||
ripper5: {
|
ripper5: {
|
|
@ -2,7 +2,7 @@
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
// License: VNPL-1.1 (see README.md for details)
|
||||||
|
|
||||||
const { compat } = require('./simple_pgs.js');
|
const { compat } = require('./simple_pgs.js');
|
||||||
const LPOptimizer = require('./lp_optimizer.js');
|
const LPOptimizer = require('./lp-optimizer.js');
|
||||||
|
|
||||||
async function run()
|
async function run()
|
||||||
{
|
{
|
|
@ -2,7 +2,7 @@
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
// License: VNPL-1.1 (see README.md for details)
|
||||||
|
|
||||||
const { compat, flatten_tree } = require('./simple_pgs.js');
|
const { compat, flatten_tree } = require('./simple_pgs.js');
|
||||||
const LPOptimizer = require('./lp_optimizer.js');
|
const LPOptimizer = require('./lp-optimizer.js');
|
||||||
|
|
||||||
const crush_tree = [
|
const crush_tree = [
|
||||||
{ level: 1, children: [
|
{ level: 1, children: [
|
|
@ -2,7 +2,7 @@
|
||||||
// License: VNPL-1.1 (see README.md for details)
|
// License: VNPL-1.1 (see README.md for details)
|
||||||
|
|
||||||
const { compat } = require('./simple_pgs.js');
|
const { compat } = require('./simple_pgs.js');
|
||||||
const LPOptimizer = require('./lp_optimizer.js');
|
const LPOptimizer = require('./lp-optimizer.js');
|
||||||
|
|
||||||
const osd_tree = {
|
const osd_tree = {
|
||||||
100: {
|
100: {
|
Some files were not shown because too many files have changed in this diff Show More
Loading…
Reference in New Issue