- name: etcd_report_interval
|
||
type: sec
|
||
default: 5
|
||
info: |
|
||
Interval at which OSDs report their liveness to etcd. Affects OSD lease time
|
||
and thus the failover speed. Lease time is equal to this parameter value
|
||
plus max_etcd_attempts * etcd_quick_timeout because it should be guaranteed
|
||
that every OSD always refreshes its lease in time.
|
||
info_ru: |
|
||
Интервал, с которым OSD сообщает о том, что жив, в etcd. Значение параметра
|
||
влияет на время резервации (lease) OSD и поэтому - на скорость переключения
|
||
при падении OSD. Время lease равняется значению этого параметра плюс
|
||
max_etcd_attempts * etcd_quick_timeout.
|
||
- name: etcd_stats_interval
|
||
type: sec
|
||
default: 30
|
||
info: |
|
||
Interval at which OSDs report their statistics to etcd. Highly affects the
|
||
imposed load on etcd, because statistics include a key for every OSD and
|
||
for every PG. At the same time, low statistic intervals make `vitastor-cli`
|
||
statistics more responsive.
|
||
info_ru: |
|
||
Интервал, с которым OSD обновляет свою статистику в etcd. Сильно влияет на
|
||
создаваемую нагрузку на etcd, потому что статистика содержит по ключу на
|
||
каждый OSD и на каждую PG. В то же время низкий интервал делает
|
||
статистику, печатаемую `vitastor-cli`, отзывчивей.
|
||
- name: run_primary
|
||
type: bool
|
||
default: true
|
||
info: |
|
||
Start primary OSD logic on this OSD. As of now, can be turned off only for
|
||
debugging purposes. It's possible to implement additional feature for the
|
||
monitor which may allow to separate primary and secondary OSDs, but it's
|
||
unclear why anyone could need it, so it's not implemented.
|
||
info_ru: |
|
||
Запускать логику первичного OSD на данном OSD. На данный момент отключать
|
||
эту опцию может иметь смысл только в целях отладки. В теории, можно
|
||
реализовать дополнительный режим для монитора, который позволит отделять
|
||
первичные OSD от вторичных, но пока не понятно, зачем это может кому-то
|
||
понадобиться, поэтому это не реализовано.
|
||
- name: osd_network
|
||
type: string or array of strings
|
||
type_ru: строка или массив строк
|
||
info: |
|
||
Network mask of the network (IPv4 or IPv6) to use for OSDs. Note that
|
||
although it's possible to specify multiple networks here, this does not
|
||
mean that OSDs will create multiple listening sockets - they'll only
|
||
pick the first matching address of an UP + RUNNING interface. Separate
|
||
networks for cluster and client connections are also not implemented, but
|
||
they are mostly useless anyway, so it's not a big deal.
|
||
info_ru: |
|
||
Маска подсети (IPv4 или IPv6) для использования для соединений с OSD.
|
||
Имейте в виду, что хотя сейчас и можно передать в этот параметр несколько
|
||
подсетей, это не означает, что OSD будут создавать несколько слушающих
|
||
сокетов - они лишь будут выбирать адрес первого поднятого (состояние UP +
|
||
RUNNING), подходящий под заданную маску. Также не реализовано разделение
|
||
кластерной и публичной сетей OSD. Правда, от него обычно всё равно довольно
|
||
мало толку, так что особенной проблемы в этом нет.
|
||
- name: bind_address
|
||
type: string
|
||
default: "0.0.0.0"
|
||
info: |
|
||
Instead of the network mask, you can also set OSD listen address explicitly
|
||
using this parameter. May be useful if you want to start OSDs on interfaces
|
||
that are not UP + RUNNING.
|
||
info_ru: |
|
||
Этим параметром можно явным образом задать адрес, на котором будет ожидать
|
||
соединений OSD (вместо использования маски подсети). Может быть полезно,
|
||
например, чтобы запускать OSD на неподнятых интерфейсах (не UP + RUNNING).
|
||
- name: bind_port
|
||
type: int
|
||
info: |
|
||
By default, OSDs pick random ports to use for incoming connections
|
||
automatically. With this option you can set a specific port for a specific
|
||
OSD by hand.
|
||
info_ru: |
|
||
По умолчанию OSD сами выбирают случайные порты для входящих подключений.
|
||
С помощью данной опции вы можете задать порт для отдельного OSD вручную.
|
||
- name: autosync_interval
|
||
type: sec
|
||
default: 5
|
||
online: true
|
||
info: |
|
||
Time interval at which automatic fsyncs/flushes are issued by each OSD when
|
||
the immediate_commit mode if disabled. fsyncs are required because without
|
||
them OSDs quickly fill their journals, become unable to clear them and
|
||
stall. Also this option limits the amount of recent uncommitted changes
|
||
which OSDs may lose in case of a power outage in case when clients don't
|
||
issue fsyncs at all.
|
||
info_ru: |
|
||
Временной интервал отправки автоматических fsync-ов (операций очистки кэша)
|
||
каждым OSD для случая, когда режим immediate_commit отключён. fsync-и нужны
|
||
OSD, чтобы успевать очищать журнал - без них OSD быстро заполняют журналы и
|
||
перестают обрабатывать операции записи. Также эта опция ограничивает объём
|
||
недавних незафиксированных изменений, которые OSD могут терять при
|
||
отключении питания, если клиенты вообще не отправляют fsync.
|
||
- name: autosync_writes
|
||
type: int
|
||
default: 128
|
||
online: true
|
||
info: |
|
||
Same as autosync_interval, but sets the maximum number of uncommitted write
|
||
operations before issuing an fsync operation internally.
|
||
info_ru: |
|
||
Аналогично autosync_interval, но задаёт не временной интервал, а
|
||
максимальное количество незафиксированных операций записи перед
|
||
принудительной отправкой fsync-а.
|
||
- name: recovery_queue_depth
|
||
type: int
|
||
default: 4
|
||
online: true
|
||
info: |
|
||
Maximum recovery operations per one primary OSD at any given moment of time.
|
||
Currently it's the only parameter available to tune the speed or recovery
|
||
and rebalancing, but it's planned to implement more.
|
||
info_ru: |
|
||
Максимальное число операций восстановления на одном первичном OSD в любой
|
||
момент времени. На данный момент единственный параметр, который можно менять
|
||
для ускорения или замедления восстановления и перебалансировки данных, но
|
||
в планах реализация других параметров.
|
||
- name: recovery_pg_switch
|
||
type: int
|
||
default: 128
|
||
online: true
|
||
info: |
|
||
Number of recovery operations before switching to recovery of the next PG.
|
||
The idea is to mix all PGs during recovery for more even space and load
|
||
distribution but still benefit from recovery queue depth greater than 1.
|
||
Degraded PGs are anyway scanned first.
|
||
info_ru: |
|
||
Число операций восстановления перед переключением на восстановление другой PG.
|
||
Идея заключается в том, чтобы восстанавливать все PG одновременно для более
|
||
равномерного распределения места и нагрузки, но при этом всё равно выигрывать
|
||
от глубины очереди восстановления, большей, чем 1. Деградированные PG в любом
|
||
случае сканируются первыми.
|
||
- name: recovery_sync_batch
|
||
type: int
|
||
default: 16
|
||
online: true
|
||
info: Maximum number of recovery operations before issuing an additional fsync.
|
||
info_ru: Максимальное число операций восстановления перед дополнительным fsync.
|
||
- name: readonly
|
||
type: bool
|
||
default: false
|
||
info: |
|
||
Read-only mode. If this is enabled, an OSD will never issue any writes to
|
||
the underlying device. This may be useful for recovery purposes.
|
||
info_ru: |
|
||
Режим "только чтение". Если включить этот режим, OSD не будет писать ничего
|
||
на диск. Может быть полезно в целях восстановления.
|
||
- name: no_recovery
|
||
type: bool
|
||
default: false
|
||
online: true
|
||
info: |
|
||
Disable automatic background recovery of objects. Note that it doesn't
|
||
affect implicit recovery of objects happening during writes - a write is
|
||
always made to a full set of at least pg_minsize OSDs.
|
||
info_ru: |
|
||
Отключить автоматическое фоновое восстановление объектов. Обратите внимание,
|
||
что эта опция не отключает восстановление объектов, происходящее при
|
||
записи - запись всегда производится в полный набор из как минимум pg_minsize
|
||
OSD.
|
||
- name: no_rebalance
|
||
type: bool
|
||
default: false
|
||
online: true
|
||
info: |
|
||
Disable background movement of data between different OSDs. Disabling it
|
||
means that PGs in the `has_misplaced` state will be left in it indefinitely.
|
||
info_ru: |
|
||
Отключить фоновое перемещение объектов между разными OSD. Отключение
|
||
означает, что PG, находящиеся в состоянии `has_misplaced`, будут оставлены
|
||
в нём на неопределённый срок.
|
||
- name: print_stats_interval
|
||
type: sec
|
||
default: 3
|
||
online: true
|
||
info: |
|
||
Time interval at which OSDs print simple human-readable operation
|
||
statistics on stdout.
|
||
info_ru: |
|
||
Временной интервал, с которым OSD печатают простую человекочитаемую
|
||
статистику выполнения операций в стандартный вывод.
|
||
- name: slow_log_interval
|
||
type: sec
|
||
default: 10
|
||
online: true
|
||
info: |
|
||
Time interval at which OSDs dump slow or stuck operations on stdout, if
|
||
they're any. Also it's the time after which an operation is considered
|
||
"slow".
|
||
info_ru: |
|
||
Временной интервал, с которым OSD выводят в стандартный вывод список
|
||
медленных или зависших операций, если таковые имеются. Также время, при
|
||
превышении которого операция считается "медленной".
|
||
- name: inode_vanish_time
|
||
type: sec
|
||
default: 60
|
||
online: true
|
||
info: |
|
||
Number of seconds after which a deleted inode is removed from OSD statistics.
|
||
info_ru: |
|
||
Число секунд, через которое удалённые инод удаляется и из статистики OSD.
|
||
- name: max_write_iodepth
|
||
type: int
|
||
default: 128
|
||
online: true
|
||
info: |
|
||
Parallel client write operation limit per one OSD. Operations that exceed
|
||
this limit are pushed to a temporary queue instead of being executed
|
||
immediately.
|
||
info_ru: |
|
||
Максимальное число одновременных клиентских операций записи на один OSD.
|
||
Операции, превышающие этот лимит, не исполняются сразу, а сохраняются во
|
||
временной очереди.
|
||
- name: min_flusher_count
|
||
type: int
|
||
default: 1
|
||
online: true
|
||
info: |
|
||
Flusher is a micro-thread that moves data from the journal to the data
|
||
area of the device. Their number is auto-tuned between minimum and maximum.
|
||
Minimum number is set by this parameter.
|
||
info_ru: |
|
||
Flusher - это микро-поток (корутина), которая копирует данные из журнала в
|
||
основную область устройства данных. Их число настраивается динамически между
|
||
минимальным и максимальным значением. Этот параметр задаёт минимальное число.
|
||
- name: max_flusher_count
|
||
type: int
|
||
default: 256
|
||
online: true
|
||
info: |
|
||
Maximum number of journal flushers (see above min_flusher_count).
|
||
info_ru: |
|
||
Максимальное число микро-потоков очистки журнала (см. выше min_flusher_count).
|
||
- name: inmemory_metadata
|
||
type: bool
|
||
default: true
|
||
info: |
|
||
This parameter makes Vitastor always keep metadata area of the block device
|
||
in memory. It's required for good performance because it allows to avoid
|
||
additional read-modify-write cycles during metadata modifications. Metadata
|
||
area size is currently roughly 224 MB per 1 TB of data. You can turn it off
|
||
to reduce memory usage by this value, but it will hurt performance. This
|
||
restriction is likely to be removed in the future along with the upgrade
|
||
of the metadata storage scheme.
|
||
info_ru: |
|
||
Данный параметр заставляет Vitastor всегда держать область метаданных диска
|
||
в памяти. Это нужно, чтобы избегать дополнительных операций чтения с диска
|
||
при записи. Размер области метаданных на данный момент составляет примерно
|
||
224 МБ на 1 ТБ данных. При включении потребление памяти снизится примерно
|
||
на эту величину, но при этом также снизится и производительность. В будущем,
|
||
после обновления схемы хранения метаданных, это ограничение, скорее всего,
|
||
будет ликвидировано.
|
||
- name: inmemory_journal
|
||
type: bool
|
||
default: true
|
||
info: |
|
||
This parameter make Vitastor always keep journal area of the block
|
||
device in memory. Turning it off will, again, reduce memory usage, but
|
||
hurt performance because flusher coroutines will have to read data from
|
||
the disk back before copying it into the main area. The memory usage benefit
|
||
is typically very small because it's sufficient to have 16-32 MB journal
|
||
for SSD OSDs. However, in theory it's possible that you'll want to turn it
|
||
off for hybrid (HDD+SSD) OSDs with large journals on quick devices.
|
||
info_ru: |
|
||
Данный параметр заставляет Vitastor всегда держать в памяти журналы OSD.
|
||
Отключение параметра, опять же, снижает потребление памяти, но ухудшает
|
||
производительность, так как для копирования данных из журнала в основную
|
||
область устройства OSD будут вынуждены читать их обратно с диска. Выигрыш
|
||
по памяти при этом обычно крайне низкий, так как для SSD OSD обычно
|
||
достаточно 16- или 32-мегабайтного журнала. Однако в теории отключение
|
||
параметра может оказаться полезным для гибридных OSD (HDD+SSD) с большими
|
||
журналами, расположенными на быстром по сравнению с HDD устройстве.
|
||
- name: data_io
|
||
type: string
|
||
default: direct
|
||
info: |
|
||
I/O mode for *data*. One of "direct", "cached" or "directsync". Corresponds
|
||
to O_DIRECT, O_SYNC and O_DIRECT|O_SYNC, respectively.
|
||
|
||
Choose "cached" to use Linux page cache. This may improve read performance
|
||
for hot data and slower disks - HDDs and maybe SATA SSDs - but will slightly
|
||
decrease write performance for fast disks because page cache is an overhead
|
||
itself.
|
||
|
||
Choose "directsync" to use [immediate_commit](layout-cluster.ru.md#immediate_commit)
|
||
(which requires disable_data_fsync) with drives having write-back cache
|
||
which can't be turned off, for example, Intel Optane. Also note that *some*
|
||
desktop SSDs (for example, HP EX950) may ignore O_SYNC thus making
|
||
disable_data_fsync unsafe even with "directsync".
|
||
info_ru: |
|
||
Режим ввода-вывода для *данных*. Одно из значений "direct", "cached" или
|
||
"directsync", означающих O_DIRECT, O_SYNC и O_DIRECT|O_SYNC, соответственно.
|
||
|
||
Выберите "cached", чтобы использовать системный кэш Linux (page cache) при
|
||
чтении и записи. Это может улучшить скорость чтения горячих данных с
|
||
относительно медленных дисков - HDD и, возможно, SATA SSD - но немного
|
||
снижает производительность записи для быстрых дисков, так как кэш сам по
|
||
себе тоже добавляет накладные расходы.
|
||
|
||
Выберите "directsync", если хотите задействовать
|
||
[immediate_commit](layout-cluster.ru.md#immediate_commit) (требующий
|
||
включенияd disable_data_fsync) на дисках с неотключаемым кэшем. Пример таких
|
||
дисков - Intel Optane. При этом также стоит иметь в виду, что *некоторые*
|
||
настольные SSD (например, HP EX950) игнорируют флаг O_SYNC, делая отключение
|
||
fsync небезопасным даже с режимом "directsync".
|
||
- name: meta_io
|
||
type: string
|
||
default: direct
|
||
info: |
|
||
I/O mode for *metadata*. One of "direct", "cached" or "directsync".
|
||
|
||
"cached" may improve read performance, but only under the following conditions:
|
||
1. your drives are relatively slow (HDD, SATA SSD), and
|
||
2. checksums are enabled, and
|
||
3. [inmemory_metadata](#inmemory_metadata) is disabled.
|
||
Under all these conditions, metadata blocks are read from disk on every
|
||
read request to verify checksums and caching them may reduce this extra
|
||
read load. Without (3) metadata is never read from the disk after starting,
|
||
and without (2) metadata blocks are read from disk only during journal
|
||
flushing.
|
||
|
||
"directsync" is the same as above.
|
||
|
||
If the same device is used for data and metadata, meta_io by default is set
|
||
to the same value as [data_io](#data_io).
|
||
info_ru: |
|
||
Режим ввода-вывода для *метаданных*. Одно из значений "direct", "cached" или
|
||
"directsync".
|
||
|
||
"cached" может улучшить скорость чтения, если:
|
||
1. у вас медленные диски (HDD, SATA SSD)
|
||
2. контрольные суммы включены
|
||
3. параметр [inmemory_metadata](#inmemory_metadata) отключён.
|
||
При этих условиях блоки метаданных читаются с диска при каждом запросе чтения
|
||
для проверки контрольных сумм и их кэширование может снизить дополнительную
|
||
нагрузку на диск. Без (3) метаданные никогда не читаются с диска после
|
||
запуска OSD, а без (2) блоки метаданных читаются только при сбросе журнала.
|
||
|
||
Если одно и то же устройство используется для данных и метаданных, режим
|
||
ввода-вывода метаданных по умолчанию устанавливается равным [data_io](#data_io).
|
||
- name: journal_io
|
||
type: string
|
||
default: direct
|
||
info: |
|
||
I/O mode for *journal*. One of "direct", "cached" or "directsync".
|
||
|
||
Here, "cached" may only improve read performance for recent writes and
|
||
only if [inmemory_journal](#inmemory_journal) is turned off.
|
||
|
||
If the same device is used for metadata and journal, journal_io by default
|
||
is set to the same value as [meta_io](#meta_io).
|
||
info_ru: |
|
||
Режим ввода-вывода для *журнала*. Одно из значений "direct", "cached" или
|
||
"directsync".
|
||
|
||
Здесь "cached" может улучшить скорость чтения только недавно записанных
|
||
данных и только если параметр [inmemory_journal](#inmemory_journal)
|
||
отключён.
|
||
|
||
Если одно и то же устройство используется для метаданных и журнала,
|
||
режим ввода-вывода журнала по умолчанию устанавливается равным
|
||
[meta_io](#meta_io).
|
||
- name: journal_sector_buffer_count
|
||
type: int
|
||
default: 32
|
||
info: |
|
||
Maximum number of buffers that can be used for writing journal metadata
|
||
blocks. The only situation when you should increase it to a larger value
|
||
is when you enable journal_no_same_sector_overwrites. In this case set
|
||
it to, for example, 1024.
|
||
info_ru: |
|
||
Максимальное число буферов, разрешённых для использования под записываемые
|
||
в журнал блоки метаданных. Единственная ситуация, в которой этот параметр
|
||
нужно менять - это если вы включаете journal_no_same_sector_overwrites. В
|
||
этом случае установите данный параметр, например, в 1024.
|
||
- name: journal_no_same_sector_overwrites
|
||
type: bool
|
||
default: false
|
||
info: |
|
||
Enable this option for SSDs like Intel D3-S4510 and D3-S4610 which REALLY
|
||
don't like when a program overwrites the same sector multiple times in a
|
||
row and slow down significantly (from 25000+ iops to ~3000 iops). When
|
||
this option is set, Vitastor will always move to the next sector of the
|
||
journal after writing it instead of possibly overwriting it the second time.
|
||
|
||
Most (99%) other SSDs don't need this option.
|
||
info_ru: |
|
||
Включайте данную опцию для SSD вроде Intel D3-S4510 и D3-S4610, которые
|
||
ОЧЕНЬ не любят, когда ПО перезаписывает один и тот же сектор несколько раз
|
||
подряд. Такие SSD при многократной перезаписи одного и того же сектора
|
||
сильно замедляются - условно, с 25000 и более iops до 3000 iops. Когда
|
||
данная опция установлена, Vitastor всегда переходит к следующему сектору
|
||
журнала после записи вместо потенциально повторной перезаписи того же
|
||
самого сектора.
|
||
|
||
Почти все другие SSD (99% моделей) не требуют данной опции.
|
||
- name: throttle_small_writes
|
||
type: bool
|
||
default: false
|
||
online: true
|
||
info: |
|
||
Enable soft throttling of small journaled writes. Useful for hybrid OSDs
|
||
with fast journal/metadata devices and slow data devices. The idea is that
|
||
small writes complete very quickly because they're first written to the
|
||
journal device, but moving them to the main device is slow. So if an OSD
|
||
allows clients to issue a lot of small writes it will perform very good
|
||
for several seconds and then the journal will fill up and the performance
|
||
will drop to almost zero. Throttling is meant to prevent this problem by
|
||
artifically slowing quick writes down based on the amount of free space in
|
||
the journal. When throttling is used, the performance of small writes will
|
||
decrease smoothly instead of abrupt drop at the moment when the journal
|
||
fills up.
|
||
info_ru: |
|
||
Разрешить мягкое ограничение скорости журналируемой записи. Полезно для
|
||
гибридных OSD с быстрыми устройствами метаданных и медленными устройствами
|
||
данных. Идея заключается в том, что мелкие записи в этой ситуации могут
|
||
завершаться очень быстро, так как они изначально записываются на быстрое
|
||
журнальное устройство (SSD). Но перемещать их потом на основное медленное
|
||
устройство долго. Поэтому если OSD быстро примет от клиентов очень много
|
||
мелких операций записи, он быстро заполнит свой журнал, после чего
|
||
производительность записи резко упадёт практически до нуля. Ограничение
|
||
скорости записи призвано решить эту проблему с помощью искусственного
|
||
замедления операций записи на основании объёма свободного места в журнале.
|
||
Когда эта опция включена, производительность мелких операций записи будет
|
||
снижаться плавно, а не резко в момент окончательного заполнения журнала.
|
||
- name: throttle_target_iops
|
||
type: int
|
||
default: 100
|
||
online: true
|
||
info: |
|
||
Target maximum number of throttled operations per second under the condition
|
||
of full journal. Set it to approximate random write iops of your data devices
|
||
(HDDs).
|
||
info_ru: |
|
||
Расчётное максимальное число ограничиваемых операций в секунду при условии
|
||
отсутствия свободного места в журнале. Устанавливайте приблизительно равным
|
||
максимальной производительности случайной записи ваших устройств данных
|
||
(HDD) в операциях в секунду.
|
||
- name: throttle_target_mbs
|
||
type: int
|
||
default: 100
|
||
online: true
|
||
info: |
|
||
Target maximum bandwidth in MB/s of throttled operations per second under
|
||
the condition of full journal. Set it to approximate linear write
|
||
performance of your data devices (HDDs).
|
||
info_ru: |
|
||
Расчётный максимальный размер в МБ/с ограничиваемых операций в секунду при
|
||
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
|
||
равным максимальной производительности линейной записи ваших устройств
|
||
данных (HDD).
|
||
- name: throttle_target_parallelism
|
||
type: int
|
||
default: 1
|
||
online: true
|
||
info: |
|
||
Target maximum parallelism of throttled operations under the condition of
|
||
full journal. Set it to approximate internal parallelism of your data
|
||
devices (1 for HDDs, 4-8 for SSDs).
|
||
info_ru: |
|
||
Расчётный максимальный параллелизм ограничиваемых операций в секунду при
|
||
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
|
||
равным внутреннему параллелизму ваших устройств данных (1 для HDD, 4-8
|
||
для SSD).
|
||
- name: throttle_threshold_us
|
||
type: us
|
||
default: 50
|
||
online: true
|
||
info: |
|
||
Minimal computed delay to be applied to throttled operations. Usually
|
||
doesn't need to be changed.
|
||
info_ru: |
|
||
Минимальная применимая к ограничиваемым операциям задержка. Обычно не
|
||
требует изменений.
|
||
- name: osd_memlock
|
||
type: bool
|
||
default: false
|
||
info: |
|
||
Lock all OSD memory to prevent it from being unloaded into swap with
|
||
mlockall(). Requires sufficient ulimit -l (max locked memory).
|
||
info_ru: |
|
||
Блокировать всю память OSD с помощью mlockall, чтобы запретить её выгрузку
|
||
в пространство подкачки. Требует достаточного значения ulimit -l (лимита
|
||
заблокированной памяти).
|
||
- name: auto_scrub
|
||
type: bool
|
||
default: false
|
||
online: true
|
||
info: |
|
||
Data scrubbing is the process of background verification of copies to find
|
||
and repair corrupted blocks. It's not run automatically by default since
|
||
it's a new feature. Set this parameter to true to enable automatic scrubs.
|
||
|
||
This parameter makes OSDs automatically schedule data scrubbing of clean PGs
|
||
every `scrub_interval` (see below). You can also start/schedule scrubbing
|
||
manually by setting `next_scrub` JSON key to the desired UNIX time of the
|
||
next scrub in `/pg/history/...` values in etcd.
|
||
info_ru: |
|
||
Скраб - процесс фоновой проверки копий данных, предназначенный, чтобы
|
||
находить и исправлять повреждённые блоки. По умолчанию эти проверки ещё не
|
||
запускаются автоматически, так как являются новой функцией. Чтобы включить
|
||
автоматическое планирование скрабов, установите данный параметр в true.
|
||
|
||
Включённый параметр заставляет OSD автоматически планировать фоновую
|
||
проверку чистых PG раз в `scrub_interval` (см. ниже). Вы также можете
|
||
запустить или запланировать проверку вручную, установив значение ключа JSON
|
||
`next_scrub` внутри ключей etcd `/pg/history/...` в UNIX-время следующей
|
||
желаемой проверки.
|
||
- name: no_scrub
|
||
type: bool
|
||
default: false
|
||
online: true
|
||
info: |
|
||
Temporarily disable scrubbing and stop running scrubs.
|
||
info_ru: |
|
||
Временно отключить и остановить запущенные скрабы.
|
||
- name: scrub_interval
|
||
type: string
|
||
default: 30d
|
||
online: true
|
||
info: |
|
||
Default automatic scrubbing interval for all pools. Numbers without suffix
|
||
are treated as seconds, possible unit suffixes include 's' (seconds),
|
||
'm' (minutes), 'h' (hours), 'd' (days), 'M' (months) and 'y' (years).
|
||
info_ru: |
|
||
Интервал автоматической фоновой проверки по умолчанию для всех пулов.
|
||
Значения без указанной единицы измерения считаются в секундах, допустимые
|
||
символы единиц измерения в конце: 's' (секунды),
|
||
'm' (минуты), 'h' (часы), 'd' (дни), 'M' (месяца) или 'y' (годы).
|
||
- name: scrub_queue_depth
|
||
type: int
|
||
default: 1
|
||
online: true
|
||
info: |
|
||
Number of parallel scrubbing operations per one OSD.
|
||
info_ru: |
|
||
Число параллельных операций фоновой проверки на один OSD.
|
||
- name: scrub_sleep
|
||
type: ms
|
||
default: 0
|
||
online: true
|
||
info: |
|
||
Additional interval between two consecutive scrubbing operations on one OSD.
|
||
Can be used to slow down scrubbing if it affects user load too much.
|
||
info_ru: |
|
||
Дополнительный интервал ожидания после фоновой проверки каждого объекта на
|
||
одном OSD. Может использоваться для замедления скраба, если он слишком
|
||
сильно влияет на пользовательскую нагрузку.
|
||
- name: scrub_list_limit
|
||
type: int
|
||
default: 1000
|
||
online: true
|
||
info: |
|
||
Number of objects to list in one listing operation during scrub.
|
||
info_ru: |
|
||
Размер загружаемых за одну операцию списков объектов в процессе фоновой
|
||
проверки.
|
||
- name: scrub_find_best
|
||
type: bool
|
||
default: true
|
||
online: true
|
||
info: |
|
||
Find and automatically restore best versions of objects with unmatched
|
||
copies. In replicated setups, the best version is the version with most
|
||
matching replicas. In EC setups, the best version is the subset of data
|
||
and parity chunks without mismatches.
|
||
|
||
The hypothetical situation where you might want to disable it is when
|
||
you have 3 replicas and you are paranoid that 2 HDDs out of 3 may silently
|
||
corrupt an object in the same way (for example, zero it out) and only
|
||
1 HDD will remain good. In this case disabling scrub_find_best may help
|
||
you to recover the data! See also scrub_ec_max_bruteforce below.
|
||
info_ru: |
|
||
Находить и автоматически восстанавливать "лучшие версии" объектов с
|
||
несовпадающими копиями/частями. При использовании репликации "лучшая"
|
||
версия - версия, доступная в большем числе экземпляров, чем другие. При
|
||
использовании кодов коррекции ошибок "лучшая" версия - это подмножество
|
||
частей данных и чётности, полностью соответствующих друг другу.
|
||
|
||
Гипотетическая ситуация, в которой вы можете захотеть отключить этот
|
||
поиск - это если у вас 3 реплики и вы боитесь, что 2 диска из 3 могут
|
||
незаметно и одинаково повредить данные одного и того же объекта, например,
|
||
занулив его, и только 1 диск останется неповреждённым. В этой ситуации
|
||
отключение этого параметра поможет вам восстановить данные! Смотрите также
|
||
описание следующего параметра - scrub_ec_max_bruteforce.
|
||
- name: scrub_ec_max_bruteforce
|
||
type: int
|
||
default: 100
|
||
online: true
|
||
info: |
|
||
Vitastor can locate corrupted chunks in EC setups with more than 1 parity
|
||
chunk by brute-forcing all possible error locations. This configuration
|
||
value limits the maximum number of checked combinations. You can try to
|
||
increase it if you have EC N+K setup with N and K large enough for
|
||
combination count `C(N+K-1, K-1) = (N+K-1)! / (K-1)! / N!` to be greater
|
||
than the default 100.
|
||
|
||
If there are too many possible combinations or if multiple combinations give
|
||
correct results then objects are marked inconsistent and aren't recovered
|
||
automatically.
|
||
|
||
In replicated setups bruteforcing isn't needed, Vitastor just assumes that
|
||
the variant with most available equal copies is correct. For example, if
|
||
you have 3 replicas and 1 of them differs, this one is considered to be
|
||
corrupted. But if there is no "best" version with more copies than all
|
||
others have then the object is also marked as inconsistent.
|
||
info_ru: |
|
||
Vitastor старается определить повреждённые части объектов при использовании
|
||
EC (кодов коррекции ошибок) с более, чем 1 диском чётности, путём перебора
|
||
всех возможных комбинаций ошибочных частей. Данное значение конфигурации
|
||
ограничивает число перебираемых комбинаций. Вы можете попробовать поднять
|
||
его, если используете схему кодирования EC N+K с N и K, достаточно большими
|
||
для того, чтобы число сочетаний `C(N+K-1, K-1) = (N+K-1)! / (K-1)! / N!`
|
||
было больше, чем стандартное значение 100.
|
||
|
||
Если возможных комбинаций слишком много или если корректная комбинаций не
|
||
определяется однозначно, объекты помечаются неконсистентными (inconsistent)
|
||
и не восстанавливаются автоматически.
|
||
|
||
При использовании репликации перебор не нужен, Vitastor просто предполагает,
|
||
что вариант объекта с наибольшим количеством одинаковых копий корректен.
|
||
Например, если вы используете 3 реплики и 1 из них отличается, эта 1 копия
|
||
считается некорректной. Однако, если "лучшую" версию с числом доступных
|
||
копий большим, чем у всех других версий, найти невозможно, то объект тоже
|
||
маркируется неконсистентным.
|