1
0
Fork 0

Compare commits

..

1053 Commits

Author SHA1 Message Date
Zibort Cloud f96cbe696f Small fix due to the new functionality in cinder "Skip sparse copy during volume reimage" 8d7e292bcd 2024-06-27 11:45:05 +03:00
Vitaliy Filippov f59456f22d Add libvirt 10.4 patch (same as 9.10 actually) 2024-06-27 01:35:29 +03:00
Vitaliy Filippov ca63cd507d Fix possible infinite loop in flusher (surprisingly reproduced in test_write.sh with iothreads) 2024-06-27 00:38:01 +03:00
Vitaliy Filippov ea0d72289c Treat copied buffers as written only after completing the write in client
SYNC operation fsyncs only completed operations, so treating writes as "eligible
for fsync" before actually completing them is incorrect

It affected SCHEME=ec test_heal.sh (with immediate_commit=none) test - it was
flapping with lost writes - some non-fsynced writes were legitimately lost by
the OSD, but weren't repeated by the client
2024-06-20 02:11:53 +03:00
Vitaliy Filippov e400a851f4 Repeat dirty buffer flushes on any PG primary change because the new primary may not know about unfinished operations of the old primary 2024-06-19 00:28:26 +03:00
Vitaliy Filippov 0fec7a9fea Drop dirty peer connections also when stopping PG to guarantee that clients do not miss fsync 2024-06-19 00:28:26 +03:00
Vitaliy Filippov b9de2a92a9 Print OSD performance stats 2024-06-17 13:02:58 +03:00
Vitaliy Filippov 5360a70853 Make OSD also report derived stats 2024-06-17 13:02:52 +03:00
Vitaliy Filippov 4c2328eb13 Implement ls-osd command 2024-06-17 02:22:14 +03:00
Vitaliy Filippov 313daef12d Slightly decopypaste etcd key parsing 2024-06-17 01:38:42 +03:00
Vitaliy Filippov ad9c12e1b9 Fix Pseudo-FS initialization leading to ENOENTs some time after start 2024-06-16 23:43:09 +03:00
Vitaliy Filippov 4473eb5512 Fix slow & failing CAS layer merge 2024-06-14 02:15:49 +03:00
Vitaliy Filippov 6501abc060 Set default etcd_ws_keepalive_interval to 5 2024-06-08 00:38:48 +03:00
Vitaliy Filippov 1228403e74 Implement internal restart / run_forever in monitor 2024-06-08 00:35:18 +03:00
Vitaliy Filippov 4eabebd245 Put all configuration to Mon.config 2024-06-07 00:20:38 +03:00
Vitaliy Filippov cf60b6818c Extract PG generation into pg_gen.js 2024-06-05 11:22:06 +03:00
Vitaliy Filippov 1a4a7cdc37 Extract OSD Tree generation functions to osd_tree.js 2024-06-05 11:19:35 +03:00
Vitaliy Filippov 1b48085e21 Extract remote etcd interaction to etcd_adapter.js 2024-06-05 11:19:35 +03:00
Vitaliy Filippov a71847244e Rename PGUtil.js to pg_utils.js 2024-06-05 10:51:20 +03:00
Vitaliy Filippov 848c2d2722 Move LPOptimizer, DSL and tests to lp_optimizer/ 2024-06-05 10:51:20 +03:00
Vitaliy Filippov 86832dc43f Add eslint import/no-unresolved 2024-06-05 10:51:20 +03:00
Vitaliy Filippov 1f6da79463 Extract stats calculation into a separate file 2024-06-05 10:51:20 +03:00
Vitaliy Filippov 9bf57c3760 Mention generic Toshiba MG instead of specific MGxx, fix russian vitastorfs link 2024-06-05 02:08:09 +03:00
Vitaliy Filippov a0305b5b4a Extract pool configuration validation into a separate file 2024-06-05 02:08:08 +03:00
Vitaliy Filippov 1546f8e447 Extract etcd data "schema" into a separate file 2024-06-05 02:07:53 +03:00
Vitaliy Filippov 8ce962b312 Move scripts 2024-06-05 02:07:53 +03:00
Vitaliy Filippov 50e56b3b92 Add vitastor_c_inode_get_immediate_commit 2024-05-19 01:57:18 +03:00
Vitaliy Filippov a12d328793 Rename cli/ to cmd/, fix cmake install 2024-05-15 23:04:50 +03:00
Vitaliy Filippov c79b38bd26 Move all sources to subdirs 2024-05-15 11:06:01 +03:00
Vitaliy Filippov 44692d148a Make vitastor_kv.h header public 2024-05-15 01:49:38 +03:00
Vitaliy Filippov ba52359611 Fix last master commit 2024-05-15 01:49:31 +03:00
Vitaliy Filippov 23a9aa93b5 Fix pool create/modify --block_size validation 2024-05-04 16:33:22 +03:00
Vitaliy Filippov 2412d9e239 Fix TTL comparison for lease/keepalive 2024-04-30 01:53:05 +03:00
Vitaliy Filippov 9301c857b1 Release 1.6.1
A bunch of monitor fixes

- Add noout flag for OSDs (/vitastor/config/osd/xx)
- Fix "effective" size of degraded PGs (and thus "used space") calculation in monitor
- Fix monitor not clearing PGs of deleted pools
- Fix incorrect PG generation with hosts with 0 OSDs
- Fix monitor crashing during primary OSD recheck when pool has no PGs
- Fix monitor crashing when node_placement included non-existing OSDs
- Fix possible data movement after removing OSDs reweighted to 0
- Remove extra empty keys from pool configurations created by vitastor-cli create-pool
- Fix 32-bit build
2024-04-22 02:01:29 +03:00
Vitaliy Filippov 3094358ec2 Fix autovivification leading to extra empty keys in pool-create 2024-04-20 02:04:09 +03:00
Vitaliy Filippov 87f666d2a2 Filter out OSDs reweighted to 0 2024-04-20 02:03:53 +03:00
Vitaliy Filippov bd7fe4ef8f Filter out non-existing OSDs added in node_placement 2024-04-20 02:03:36 +03:00
Vitaliy Filippov 1b3f9a1416 Do not set non-existing OSD weight to 0, we'll remove them instead 2024-04-20 02:03:11 +03:00
Vitaliy Filippov a7b7354f38 Do not recheck primary distribution when pool has no PGs 2024-04-20 02:02:47 +03:00
Vitaliy Filippov 765befa22f Remove empty nodes from tree because PG DSL expects that all leaf nodes are OSDs 2024-04-20 02:02:28 +03:00
Vitaliy Filippov 87b3ab94fe Do not disable require-atomic-updates and no-unused-vars 2024-04-20 02:02:13 +03:00
Vitaliy Filippov 2c0801f6e4 Configure ESLint and add it to CI 2024-04-16 02:39:31 +03:00
Vitaliy Filippov fd83fef1d9 Fix pool deletion 2024-04-16 02:20:26 +03:00
Vitaliy Filippov 8d1067971b Fix pg_effsize (and thus "used space") calculation in monitor 2024-04-16 02:20:18 +03:00
Vitaliy Filippov ae5af04fde Add noout flag for OSDs 2024-04-16 02:19:55 +03:00
Vitaliy Filippov 266d038b11 Fix 32-bit build warnings and one error again :-) 2024-04-11 22:49:33 +03:00
Vitaliy Filippov ff4414d37e Release 1.6.0
New features:

- Implement "hierarchical failure domains" and other complex distribution rules, for example
  EC 4+2 over 3 DC, with 2 chunks per each DC ([documentation](docs/config/pool.en.md#level_placement))
- Make OSDs handle ENOSPC - now cluster stays online even if some OSDs fill up
  to 100 %, only writes requiring free space hang
- Implement Stage/Unstage & volume locking for CSI to prevent parallel mounting
  and/or modifications of the same volume
- Warn about full and almost full OSDs in vitastor-cli status
- Add an experimental NBD netlink map mode as an option ([documentation](docs/usage/nbd.en.md))
- Add --pg parameter to vitastor-cli describe, print objects with 0x in human-readable format too
- Add [administration docs](docs/usage/admin.en.md)

Bug fixes:

- Fix client operation retry timeout - previously the timeout wasn't applied and writes were
  retries almost instantly
- Fix monitors crashing on invalid pool configurations
- Fix journaling - make each journal write wait for all previous journal writes
- Fix monitor thinking that OSD weight is 0 after deleting /osd/config/ key online
- Fix a write stall caused by flusher possibly not trimming journal on rollback
- Set 32k csum_block_size for HDD by default in vitastor-disk
2024-04-09 16:57:59 +03:00
Vitaliy Filippov 0fa7ecc03f Add also a test for OSD tags 2024-04-09 16:57:59 +03:00
Vitaliy Filippov c29bfe12eb Oops - fix filter_by_root_node, add a test for it 2024-04-09 15:48:44 +03:00
Vitaliy Filippov 57bf84ddb2 Fix filtering in mon 2024-04-09 14:51:05 +03:00
Vitaliy Filippov dff4879c8c Check if NBD_ATTR_BACKEND_IDENTIFIER is defined 2024-04-09 13:16:58 +03:00
Vitaliy Filippov af9a853db6 Move NBD netlink map&unmap to separate commands, add "netlink-revive" command 2024-04-08 16:34:41 +03:00
Vitaliy Filippov b7a3275af3 Make netlink optional 2024-04-08 01:51:28 +03:00
Vitaliy Filippov 64c5c4ca26 Fix code style 2024-04-08 01:35:03 +03:00
idelson 442a9d838d nbd-proxy: add configuration via netlink to support kinds of timeouts.
PR #58 - https://github.com/vitalif/vitastor/pull/58/commits

By MIND Software LLC

By submitting this pull request, I accept Vitastor CLA
2024-04-08 00:50:08 +03:00
Vitaliy Filippov 6366972fe8 Warn about full and almost full OSDs in status 2024-04-07 19:39:51 +03:00
Vitaliy Filippov 2b863fb715 Add ENOSPC handling tests 2024-04-07 19:39:33 +03:00
Vitaliy Filippov 3bf4dd5abd Fix client op retry timeout - do not retry immediately 2024-04-07 19:08:36 +03:00
Vitaliy Filippov 3b84dcaedd Handle ENOSPC during write - rollback partial EC writes, remember partial replica writes 2024-04-07 18:02:05 +03:00
Vitaliy Filippov 20fbc4a745 Add --pg parameter to vitastor-cli describe, print objects with 0x in human-readable format too 2024-04-07 12:39:46 +03:00
Vitaliy Filippov 02993ee1dd Implement Stage/Unstage & volume locking for CSI to prevent parallel modifications of the same volume 2024-04-07 11:48:19 +03:00
Vitaliy Filippov 3629dbc54d Plug the new PG combinator into monitor 2024-04-07 02:44:17 +03:00
Vitaliy Filippov 29284bef40 Implement new DSL/rule-based PG generation algorithm 2024-04-07 00:36:20 +03:00
Vitaliy Filippov 6a924d6066 Extract PG combinator into a separate module 2024-04-07 00:36:20 +03:00
Vitaliy Filippov 9fe779a691 Do not die on invalid pool configurations 2024-04-07 00:36:20 +03:00
Vitaliy Filippov 31c2751b9b Move NBD/VDUSE map/unmap functions to a separate file 2024-04-07 00:36:09 +03:00
Vitaliy Filippov c5195666cd Fix journal sequencing: make each journal write wait for all previous journal writes 2024-04-06 23:53:12 +03:00
Vitaliy Filippov f36d7eb76c Fix monitor thinking that OSD weight is 0 after deleting /osd/config/ key 2024-04-05 23:14:46 +03:00
Vitaliy Filippov dd7f651de1 Add --max-request-bytes=104857600 to etcd params in tests 2024-04-05 23:14:46 +03:00
Vitaliy Filippov a2994ecd0d Fix flusher possibly not trimming journal on rollback 2024-04-05 23:14:39 +03:00
Vitaliy Filippov 5d3aaf016b Add administration docs 2024-03-31 01:54:52 +03:00
Vitaliy Filippov 0b097ca3f2 Set 32k csum_block_size for HDD by default 2024-03-30 16:16:49 +03:00
Vitaliy Filippov 989675a780 s/etcd_ws_keepalive_timeout/etcd_ws_keepalive_interval/ in docs 2024-03-26 01:56:08 +03:00
Vitaliy Filippov f8c403ec9e Add newer benchmark results 2024-03-23 18:28:48 +03:00
Vitaliy Filippov bfbb85e653 Replace -Oanything with -O3, not just -O/-O1/-O2 2024-03-18 02:03:44 +03:00
Vitaliy Filippov 9ad6822353 Release 1.5.0
After half a year of hard work, VitastorFS is finally here ! :-)

New features:
- VitastorFS, a full-featured clustered (read-write-many) file system.
  Documentation: [VitastorFS](docs/usage/nfs.en.md)
- Embedded key-value database implementation based on Parallel Optimistic B-Tree
  algorithm and used for the metadata of VitastorFS
- Pool management commands in vitastor-cli (create-pool, list-pools, rm-pool, modify-pool).
  Thanks MIND Software (https://mindsw.io) for their contribution!
  [Documentation](docs/usage/cli.en.md#create-pool)

Bug fixes:
- Fix a very rare "infinite loop" in the client library
- Fix a rare OSD hang on during start when zeroing out bad metadata entries left from the previous run
2024-03-16 15:35:10 +03:00
Vitaliy Filippov 2043b4e374 Fix build errors for gcc 8 2024-03-16 15:35:10 +03:00
Vitaliy Filippov de840e6fe3 Reduce kv-cli loadjson load parallelism to 16 2024-03-16 15:35:10 +03:00
Vitaliy Filippov b5e04bf809 Fix build warning 2024-03-16 15:35:10 +03:00
Vitaliy Filippov 8807a1623b Fix markdown tables 2024-03-16 15:35:10 +03:00
Vitaliy Filippov f12855c31b Add vitastor-kv to packages 2024-03-16 15:35:10 +03:00
Vitaliy Filippov e75dcc9a71 Add documentation for VitastorFS 2024-03-16 15:16:43 +03:00
Vitaliy Filippov 88516ab4bd Remove extra log 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 6221126b4f Allow to print simple-offsets just given the device size 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 6783d4a13c Implement fool protection for FS pools 2024-03-16 13:24:36 +03:00
Vitaliy Filippov dcbe1afac3 Store pool ID in inode metadata 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 0bde28c24a Make nfs_do_rmw a library function 2024-03-16 13:24:36 +03:00
Vitaliy Filippov bb8ca6184e Support setattr guard 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 87310ef7bb Support ctime 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 4f4b2dab80 Log NFS liveness checks 2024-03-16 13:24:36 +03:00
Vitaliy Filippov f70da82317 Add loadjson command to vitastor-kv 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e42148f347 Allow to specify KV commands on command line 2024-03-16 13:24:36 +03:00
Vitaliy Filippov c289584469 Add JSON dump format 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 018e89f867 Erase verf key left from creation from ientries on every modification 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 603dc68f11 Implement async mtime change 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 7b12342933 Allow to specify additional NFS mount options 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 44bf0f16ee Fix malloc/free in nfs_kv_read/write 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 8840c84572 Fix "bad key in etcd" in mon for FS pools 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 5b747c12ec Check if already mounted before mounting 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 05f5f46162 Fix zero used space, update mtime when moving/changing inode 2024-03-16 13:24:36 +03:00
Vitaliy Filippov b5604191c8 Ignore ECANCELED in nfs-proxy (happens in io_uring on fork) 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e871de27de Support unaligned shared_offsets, align shared file data instead of header 2024-03-16 13:24:36 +03:00
Vitaliy Filippov f600ce98e2 Implement auto-unmount local NFS server mode for vitastor-nfs 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 57605a5c13 Return error on failed shrink 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 29bd4561bb Implement rename over an existing file/directory 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 7142460ec8 Support --logfile in nfs-proxy 2024-03-16 13:24:36 +03:00
Vitaliy Filippov d03f19ebe5 Fix shared file overlap, add FIXMEs 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 88f9d18be3 Create inode, then direntry, not direntry, then inode; retry ID collisions 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 6213fbd8c6 Fix NFS shared/aligned write FIXMEs 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 3aee37eadd Allow to disable per-inode stats for VitastorFS pools 2024-03-16 13:24:36 +03:00
Vitaliy Filippov ecfc753e93 Add basic NFS tests, fix bugs 2024-03-16 13:24:36 +03:00
Vitaliy Filippov a574f9ad71 Return block NFS implementation back as an option too 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 7c235c9103 Move KV FS header into a separate file 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e5bb986164 Implement packing small files into shared inodes 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 181795d748 Split new NFS proxy implementation into multiple files 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 8cdc38805b WIP VitastorFS with metadata storage in VitastorKV 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 0cd455d17f First just recheck version without actually re-reading block in vitastor-kv 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 32ba653ba6 Fix vitastor-kv hang on reopen & unfinished closed listing 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 231d4b15fc Add loadable dump format to vitastor-kv (dump) 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 9dc4d5fd7b Fix freeing r/w buffers on errors in kv_db 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e58538fa47 Fix eviction when random_pos selects the end 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 11ac9e7024 Implement min/max list_count to make listings during performance test reasonable 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 511bc3df1c Fix and improve parallel allocation
- Do not try to allocate more DB blocks in an inode block until it's "confirmed" and "locked" by the first write
- Do not recheck for new zero DB blocks on first write into an inode block - a CAS failure means someone else is already writing into it
- Throw new allocation blocks away regardless of whether the known_version is 0 on a CAS failure
2024-03-16 13:24:36 +03:00
Vitaliy Filippov a64f0d1f73 Implement key_prefix for K/V stress test 2024-03-16 13:24:36 +03:00
Vitaliy Filippov ec5f7c6b87 More fixes
- do not overwrite a block with older version if known version is newer
  (read may start before update and end after update)
- invalidated block versions can't be remembered and trusted
- right boundary for split blocks is right_half when diving down, not key_lt
- restart update also when block is "invalidated", not just on version mismatch
- copy callback in listings to avoid closure destruction bugs too
2024-03-16 13:24:36 +03:00
Vitaliy Filippov 3ebed9a749 Add logging and one more assert 2024-03-16 13:24:36 +03:00
Vitaliy Filippov eab67a6e8f Make get_block() wait for updating when unrelated block is found along the path 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 20993d9b7a Fix a race condition where changed blocks were parsed over existing cached blocks and getting a mix of data 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 5cf9b343c0 Simplify code by removing an unneeded "optimisation" 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 79ae0aadcd Add kv_log_level, print warnings on level 1, trace ops on level 10 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 605afc3583 Fix duplicate keys in listings on parallel updates -- do not rewind key "iterator position" 2024-03-16 13:24:36 +03:00
Vitaliy Filippov c0681d8242 Implement key suffix to avoid collisions of multiple test workers 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 763e77b4f4 Do not complain on empty first block 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 19426aa4c5 Add JSON output for stress-tester 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 08f586bcec Print total stats 2024-03-16 13:24:36 +03:00
Vitaliy Filippov f1cd87473a Do not send more than op_count operations (fix segfault on finish) 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 1bd8d2da56 Add some more resiliency to serialize() 2024-03-16 13:24:36 +03:00
Vitaliy Filippov a7396d2baf Invalidate blocks being updated too 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e98a38810d Change new block allocation method: make each writer choose multiple empty PG blocks and place blocks in them 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 28c4324c36 Remove blocks from cache on unsuccessful updates 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 31ec3fa8f5 Allow to track multiple updates per block (it should never happen though) 2024-03-16 13:24:36 +03:00
Vitaliy Filippov e4fa26f60a Do not call stop_updating after failed write_new_block and after clear_block (both delete the item) 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 59ae27f9e5 Track versions of parent blocks and recheck if changed during update 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 2c6a301d9b Fix resume_split condition (key_lt can also be "") 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 01558349f8 Experiment: transform offsets for better sharding 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 36f4717d0d More post-stress-test fixes
- Prevent _split types of new blocks
- Stop updating new blocks only after the whole update, otherwise pointers
  may become invalid
- Use recheck_none for updates initially
- Use UINT64_MAX as initial block version when postponing ops, otherwise the
  check fails when the block is initially empty. This for example leads to
  writing both leaf items & block pointers (which is incorrect) into the root
  block when starting stress-test with --parallelism 32
- Fix -EINTR comparison
2024-03-16 13:24:36 +03:00
Vitaliy Filippov babaf2a0ce Print operation statistics 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 5773f1a375 K/V fixes after stress-test :-)
- track block versions correctly - per inode block (128kb) instead of tree block (4kb)
- prevent multiple parallel CAS writes of the same inode block
- add logging for EILSEQ which means invalid data in the tree
- fix get_block updated flag which was true for blocks already in cache and was leading to infinite loops on "unrelated block" errors
- apply changes to blocks in cache only after successful writes (using "virtual changes")
- do not replace cached block with an older version from disk
- recheck "unrelated blocks" (read/update collisions) until data stops changing
- track tree path correctly - do not treat split block as parent of its right half
- correctly move blocks when finding new empty place on disk
- restart updates from the beginning when one of blocks is changed by a parallel update
- fix delete using SET opcode and setting key to the empty value instead
- prevent changing the same key more than 1 time in parallel
- fix listing verification
- resume continue_updates in update_find (required because it uses continue_update itself)
- add allow_old_cached parameter to get()
2024-03-16 13:24:36 +03:00
Vitaliy Filippov 57222a9f79 Implement K/V DB stress tester 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 61ef000c6e Evict blocks based on memory limit & block usage 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 7d5e1cc393 Track blocks per level 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 5e7f27a02d Track block level 2024-03-16 13:24:36 +03:00
Vitaliy Filippov fd1d8a8520 Experimental B-Tree Vitastor embedded K/V database implementation! 2024-03-16 13:24:36 +03:00
Vitaliy Filippov c364e14c40 Stop then retry, not retry then stop 2024-03-16 13:24:36 +03:00
Vitaliy Filippov 3ebbfa0428 Fix another rare OSD hang on zeroing out entries on start 2024-03-16 13:24:36 +03:00
Vitaliy Filippov aa79d1db1c Fix incorrect "changing scheme" message in modify-pool 2024-03-06 00:41:35 +03:00
Vitaliy Filippov a1fecb7eff Move callback away when calling it in cluster_client 2024-03-06 00:41:35 +03:00
Vitaliy Filippov ff74b19423 Fix rare OSD hang on zeroing out bad entries on start 2024-03-06 00:41:35 +03:00
Vitaliy Filippov 4cf6dceed7 Merge branch 'rel-1.4' 2024-02-29 09:59:01 +03:00
Vitaliy Filippov 38b8963330 Release 1.4.8
- Do not use \r if output is not a terminal (should fix unexpected job output in proxmox)
- Fix rm/rm-data error return code, add --down-ok option to bypass the error
- Add EIO retry timeout and allow to disable these retries, rename up_wait_retry_interval to client_retry_interval
- Add ubuntu jammy build
- Wait for blockstore initialisation before starting OSD (prevent timeouts when init takes time)
- Fix a rare use-after-free in automatic sync after delete in blockstore
2024-02-29 09:58:34 +03:00
Vitaliy Filippov 77167e2920 Do not use \r if output is not a terminal 2024-02-29 00:21:17 +03:00
Vitaliy Filippov 5af23672d0 Fix rm/rm-data error return code, add --down-ok option to bypass the error 2024-02-29 00:20:10 +03:00
Vitaliy Filippov 6bf1f539a6 Add EIO retry timeout and allow to disable these retries, rename up_wait_retry_interval to client_retry_interval 2024-02-28 13:10:02 +03:00
Vitaliy Filippov 4eab26f968 Add documentation and a very basic test for pool management commands 2024-02-28 13:08:04 +03:00
Vitaliy Filippov 86243b7101 Rework & fix pool-create / pool-modify / pool-ls 2024-02-28 13:08:04 +03:00
idelson dc92851322 vitastor-cli: add commands to control pools: pool-create, pool-ls, pool-modify, pool-rm
PR #59 - https://github.com/vitalif/vitastor/pull/58/commits

By MIND Software LLC

By submitting this pull request, I accept Vitastor CLA
2024-02-28 13:08:04 +03:00
Zibort Cloud 02d1f16bbd Add ubuntu jammy build
PR #62 vitalif/vitastor#62

I accept Vitastor CLA agreement: https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md
2024-02-28 11:43:54 +03:00
Vitaliy Filippov fc413038d1 Wait for blockstore initialisation before starting OSD 2024-02-27 02:20:04 +03:00
Vitaliy Filippov 1bc0b5aab3 Fix a rare use-after-free in automatic sync after delete in blockstore
ASan report: [0] READ of size 16 at operator() /root/vitastor/src/blockstore_write.cpp:100
...[5] blockstore_impl_t::ack_sync(blockstore_op_t*) /root/vitastor/src/blockstore_sync.cpp:232
2024-02-24 00:06:36 +03:00
Vitaliy Filippov 5e934264cf Release 1.4.7
- Fix another old "BUG: Attempt to overwrite used offset" in a very simple
  case: bs=4k rw=write iodepth=16 from OSD start; add this case to tests
- Fix a rare crash with "unexpected state during flush: 0x51" possible with
  EC since 1.4.2 during rebalance and OSD outages
- Fix a rare write stall with EC & immediate_commit=none caused by sync
  operations reserving unneeded space in the journal
- Fix 32-bit build warnings, most in printf/scanf format strings
2024-02-22 12:45:52 +03:00
Vitaliy Filippov f20564b44b Fix 32-bit build warnings (99.9% in printf) 2024-02-22 12:22:16 +03:00
Vitaliy Filippov b3c15db331 32M journal by default in simple-offsets 2024-02-21 15:25:02 +03:00
Vitaliy Filippov 685bcd6ef9 Do not reserve extra space for big_writes during sync - sync itself is needed to commit and clear them 2024-02-21 13:00:14 +03:00
Vitaliy Filippov 3eb389b321 Supposed fix for "unexpected state during flush: 0x51" with EC 2024-02-21 01:32:06 +03:00
Vitaliy Filippov 3d16cde23c Fix assertions, add small sequential write test 2024-02-20 19:41:48 +03:00
Vitaliy Filippov c6406d67fc Fix journal space_check incorrectly checking for space at the beginning 2024-02-20 19:40:56 +03:00
Vitaliy Filippov f87964861d Release 1.4.6
Unwavering stabilization of 1.4.x, continued :-)

- Include the accidentally lost part of 1.4.5 journal trimming fix
- Fix a possible OSD crash with "BUG: Attempt to overwrite used offset"
  which was probably present for long time, but became apparent after
  fixing flapping tests in CI
- Fix remaining flapping tests in CI. It was the first time when tests
  actually passed without retries :-)
2024-02-20 17:01:26 +03:00
Vitaliy Filippov 62a4f45160 Raise test_scrub waiting timeout 2024-02-20 16:26:09 +03:00
Vitaliy Filippov 7048228678 Supposed fix for "BUG: Attempt to overwrite used offset" 2024-02-20 15:56:48 +03:00
Vitaliy Filippov ea73857450 Add asserts to catch "BUG: Attempt to overwrite used offset" 2024-02-20 15:56:48 +03:00
Vitaliy Filippov 6cfe38ec04 Followup to empty cur.oid as stop condition for forced trim fix 2024-02-20 15:56:38 +03:00
Vitaliy Filippov 7ae5766fdb Wait to clear has_degraded in test_heal - should fix flaps of test_heal_* in CI 2024-02-20 15:56:27 +03:00
Vitaliy Filippov f882c7dd87 Release 1.4.5
- Fix a write stall caused by incorrect journal trimming introduced in 1.4.4 :)
- Fix PGs sometimes hanging in "starting" state on mass OSD restarts
- Fix a rare crash with "map::at" during OSD pings
- Use new defaults for non-capacitor (desktop) SSDs - improves T1Q256 random write from ~6k iops to ~45k iops
- Make journal_trim_interval configurable
2024-02-16 10:13:33 +03:00
Vitaliy Filippov 26dd863c8d Fix sometimes possible crash on clients.at() during pings 2024-02-16 10:13:33 +03:00
Vitaliy Filippov 2ae859fbc6 Use min/max_flusher_count=32/256, 128M journal and autosync_writes=512 for non-capacitor SSDs by default 2024-02-16 10:13:33 +03:00
Vitaliy Filippov f6cd9f9153 Add a note about pg_minsize 2024-02-15 23:38:52 +03:00
Vitaliy Filippov 8389c0f33b Fix PGs sometimes hanging in "starting" state on mass OSD restarts 2024-02-15 23:38:52 +03:00
Vitaliy Filippov 9db2196aef Make journal_trim_interval configurable 2024-02-15 23:38:51 +03:00
Vitaliy Filippov 8d6ae662fe Use empty cur.oid as stop condition for forced trim, not journal_trim_counter 2024-02-15 23:27:17 +03:00
Vitaliy Filippov c777a0041a Release 1.4.4
A couple of fixes for EC pools

- Fix a segfault possible on partial EC overwrite in 1234 -> 5030 rebalance scenario
- Fix two problems leading to EC pools stalling on rebalance & parallel sudden stops
  of OSDs, for example during a sudden poweroff of a host:
  - Recovery auto-tuning (1.4.0 feature) could apply too large delays and stall
    the EC journal - fixed by limiting delays with a new recovery_tune_sleep_cutoff_us
    parameter (10 seconds by default) and applying recovery pauses before write
    operations, not after them, to not occupy space in the journal for long time
  - Dynamic journal space reservation (1.3.0 feature) wasn't accounting new writes
    when checking the limit so OSDs could still fill the journal fully and stall -
    fixed by including new writes into the limit
- Print etcd dbSize instead of dbSizeInUse in status
2024-02-11 16:23:08 +03:00
Vitaliy Filippov 2947ea93e8 Raise test_snapshot_chain_ec timeout to 6 minutes 2024-02-11 16:13:52 +03:00
Vitaliy Filippov 978bdc128a Apply recovery pause before writes, after commits, and do not apply it to syncs to not block EC pools from functioning 2024-02-11 16:13:52 +03:00
Vitaliy Filippov bb2f395f1e Add cutoff threshold for recovery auto-tuning 2024-02-11 16:13:52 +03:00
Vitaliy Filippov b127da40f7 Add a FIXME about incomplete PGs 2024-02-11 13:42:51 +03:00
Vitaliy Filippov ca34a6047a Fix dynamic journal space reservation: include the new write itself, too 2024-02-11 13:42:51 +03:00
Vitaliy Filippov 38ba76e893 Fix flusher sometimes being unable to trim journal when the flush queue is empty 2024-02-11 13:42:51 +03:00
Vitaliy Filippov 1e3c4edea0 Print etcd dbSize instead of dbSizeInUse in status 2024-02-11 13:42:51 +03:00
Vitaliy Filippov e7ac855b07 Fix that EC segfault (1234 -> 5030 partial overwrite) 2024-02-11 13:42:51 +03:00
Vitaliy Filippov c53357ac45 Add a test for EC segfault with partial overwrite in 1234 -> 5030 rebalance scenario 2024-02-11 13:42:51 +03:00
Vitaliy Filippov 27e9f244ec Release 1.4.3
Hotfix for hotfix O:-)

- "Write stall fix" was incomplete and EC write stalls could
  continue even on 1.4.2. Now they're finally fixed O:-)
- Make monitor ignore statistics of stopped OSDs. Previously if you stopped all
  OSDs the last total I/O numbers would remain the same indefinitely
2024-02-09 00:29:31 +03:00
Vitaliy Filippov 8e25a28a08 Ignore down OSDs in monitor statistics aggregation 2024-02-09 00:22:36 +03:00
Vitaliy Filippov 5d3317e4f2 Followup to 1.4.2 write stall fix - sadly, the previous version was not working correctly :) 2024-02-08 19:34:29 +03:00
Vitaliy Filippov 016115c0d4 Release 1.4.2
- Log to systemd by default
- Fix excessive autosyncs after every operation with disabled immediate_commit (introduced in 1.1.0)
- Fix a possible write stall with EC due to the lack of OSD wakeup after stabilizing previous writes
- Change sync operation semantics as a final fix to possible write stalls with EC and disabled immediate_commit
- Sync after deleting data in CLI rm / rm-data if immediate_commit is disabled
- Fix OSDs ignoring syncs & autosyncs for delete operations
- Fix OSD space reporting sometimes adding garbage zeros for deleted inodes (causing extra pool/stats etcd keys for deleted pools)
- Speed up monitor failover - change default etcd_mon_ttl from 30 to 5 seconds
- Speed up operation retries - change default up_wait_retry_interval to 50 ms
- Add patch for libvirt 9.10
2024-02-04 02:23:49 +03:00
Vitaliy Filippov e026de95d5 Log to systemd by default 2024-02-04 01:21:31 +03:00
Vitaliy Filippov 77c10fd1f8 In fact, do not autosync blockstore when autosync_writes=0 2024-02-03 20:37:36 +03:00
Vitaliy Filippov 581d02e581 Mark secondary OSDs with deletions as dirty to not forget to sync & autosync them 2024-02-03 20:31:08 +03:00
Vitaliy Filippov f03a9db4d9 Fix OSD space reporting sometimes adding garbage zeros for deleted inodes (causing extra pool/stats etcd keys for deleted pools) 2024-02-03 20:31:08 +03:00
Vitaliy Filippov cb9c30bc31 Sync after sending all deletes to each PG in cli rm-data 2024-02-03 20:31:08 +03:00
Vitaliy Filippov a86a380d20 Fix invalid parsing of autosync_writes in blockstore leading to autosyncs after every operation with disabled immediate_commit :D 2024-02-03 20:31:08 +03:00
Vitaliy Filippov d2b43cb118 Change default etcd_mon_ttl 2024-01-29 23:45:19 +03:00
Vitaliy Filippov cc76e6876b Fix flapping "scrub" test 2024-01-28 14:59:33 +03:00
Vitaliy Filippov 1cec62d25d Sync only completed writes
Should be a final remaining fix to EC + non-capacitor (non-immediate-commit) write hangs :).

First it was breaking non-EC ("instantly stable") writes because they sometimes
complete out of order which was leading to the following error:

terminate called after throwing an instance of 'std::runtime_error'
  what():  BUG: Unexpected dirty_entry 1000000000001:29480000 v65540 unstable state during flush: 0x151

But it is easily fixed by scanning previous and next dirty_entries in mark_stable.
2024-01-27 15:17:22 +03:00
Vitaliy Filippov 1c322b33ed Change default up_wait_retry_interval to 50 ms 2024-01-26 01:51:08 +03:00
Vitaliy Filippov d27524f441 Add patch for libvirt 9.10 2024-01-25 01:09:12 +03:00
Vitaliy Filippov ba55f91409 Release 1.4.1
- Fix a monitor crash on primary OSD switching introduced in 1.4.0
- Fix "partly outside array bounds" warnings for GCC 12 in cpp-btree
- Fix a realloc memory leak in theory possible with too large listings (OSD_OP_LIST)
2024-01-18 02:31:42 +03:00
Vitaliy Filippov 80aac39513 Add detailed formula for theoretical EC N+K random write performance 2024-01-18 00:36:32 +03:00
Vitaliy Filippov 2aa5aa7ab6 Add a test for simple master switching without PG reconfiguration
Also use osd_out_time:1 only in select tests and restart mon in tests only on connection errors
2024-01-17 00:19:01 +03:00
Vitaliy Filippov 3ca3b8a8d8 Fix recheck_pgs bug introduced in 1.4.0 2024-01-16 23:49:21 +03:00
Vitaliy Filippov 2cf649eba6 Fix "partly outside array bounds" warnings for GCC 12 in cpp-btree 2024-01-15 03:04:33 +03:00
Vitaliy Filippov 5935640a4a Add CLA PR form 2024-01-14 16:48:24 +03:00
Vitaliy Filippov d00d4dbac0 Initialize mod_revision field in etcd_state_client 2024-01-13 01:30:28 +03:00
Vitaliy Filippov 5d9d6f32a0 Fix common realloc memory leak mistakes found by cppcheck 2024-01-13 01:30:28 +03:00
Vitaliy Filippov 5280d1d561 Release 1.4.0
New features:
- Intelligent recovery/rebalance speed auto-tuning to reduce its impact on clients (see README -> Features)
- Auto-restoration of dead VDUSE daemons in CSI plugin
- Add vitastor-disk update-sb command
- Update QEMU for Debian Bookworm to 8.1 and use it for CSI plugin

Bug fixes:
- Fix pools SOMETIMES staying inactive after stopping a node due to OSDs not reacting
  to PG state changes caused by incorrect full reload of state from etcd on reconnection
- Make monitors retry pool configuration changes quickier which fixes them being unable
  to apply changes when an ongoing rebalance is quickly making a lot of PGs clean
- Fix CSI plugin not accepting array of strings as etcd address in /etc/vitastor/vitastor.conf
- Allow multiple interfaces with the same IP address, for "simple routed" full mesh network
- Do not ignore loopback addresses for OSD network (to make ECMP setups with frr possible)
- Fix a rare client crash during OSD reconnections
- Only treat data partitions as existing OSDs in vitastor-disk prepare
- Remove etcd parameter from default command examples
- Fix reported free space sometimes changing non-immediately after deletion of data from OSDs
- Fix a possible OSD crash on print_slow when bs_op is NULL
- Use the same etcd_ws_keepalive_interval in mon as in OSD
- Fix mon not using values from config when /config/global is not present
- Remove pve-storage-portal-dns-list format for vitastor_etcd_address
- Parse log_level in cluster_client
- Fix vitastor-nbd image existence check not working because of non-zeroed inode_watch fields
- Do not warn on EPIPE in client unless log_level is raised explicitly
- Fix incorrect error in CSI when searching for the device in /sys
- Remove 2 last prints to stdout in etcd_state_client
- Fix a possible OSD crash when checking corrupted journal entries
2024-01-12 01:28:33 +03:00
Vitaliy Filippov 317b0feb0a Add a note about VDUSE daemon auto-restart 2024-01-12 01:27:36 +03:00
Vitaliy Filippov 247f0552db Fix debug log "killing..." in CSI 2024-01-10 01:19:34 +03:00
Vitaliy Filippov 2f228fa96a Only treat data partitions as existing OSDs in vitastor-disk prepare 2023-12-31 11:46:47 +03:00
Vitaliy Filippov 2f6b9c0306 Remove etcd parameter from default command examples 2023-12-31 02:50:41 +03:00
Vitaliy Filippov 48b5f871e0 Add Contributor License Aggrement in Russian and English 2023-12-31 01:23:52 +03:00
Vitaliy Filippov c17f76a3e4 Add documentation for recovery auto-tuning 2023-12-31 01:23:17 +03:00
Vitaliy Filippov a6ab54b1ba Do not allow negative util_low/high 2023-12-31 01:23:17 +03:00
Vitaliy Filippov 99ee8596ea Rename min/max_util to util_low/high 2023-12-31 01:23:17 +03:00
Vitaliy Filippov c4928e6ecd Protect from try_send completing the operation immediately
Fixes a possible use-after-free in case of continue_ops() calling try_send(),
then connect_peer() -> set_timer() -> trigger_nearest() -> handle_op_part() -> continue_ops() again
2023-12-31 01:23:17 +03:00
Vitaliy Filippov ec7dcd1be5 Do not apply very large recovery pauses during tests 2023-12-31 01:23:17 +03:00
Vitaliy Filippov e600bbc151 Fix flapping move_reappear test by adding an fsync before stopping PG 2023-12-31 01:23:17 +03:00
Vitaliy Filippov 8b8c1179a7 Use a separate used_blocks counter for free space stats to hide possibly delayed on-flush deallocation 2023-12-31 01:23:17 +03:00
Vitaliy Filippov d5a6fa6dd7 Fix possible crash on print_slow when bs_op is NULL 2023-12-31 01:23:17 +03:00
Vitaliy Filippov f757a35a8d Retry PG changes without re-running lpsolve when pool configuration and OSD tree don't change
OSDs often change their /pg/history keys during rebalance, so monitor receives additional
transaction failures from etcd if it re-runs lpsolve which sometimes may even lead to monitor
being unable to apply PG changes at all until rebalance completes
2023-12-31 01:23:17 +03:00
Vitaliy Filippov 1edf86ed26 Aggregate recovery delay using simple mean over last 10 observations (EWMA is shit) 2023-12-31 01:23:17 +03:00
Vitaliy Filippov 5ca7cde612 Experiment/WIP: Try to track "secondary" recovery ops separately 2023-12-31 01:23:17 +03:00
Vitaliy Filippov 751935ddd8 WIP Auto-tune recovery speed 2023-12-31 01:23:17 +03:00
Vitaliy Filippov d84dee7098 Track recovery op latencies + refactor into a structure 2023-12-31 01:23:17 +03:00
Vitaliy Filippov dcc76eee15 Add a parity chunk count change test script 2023-12-26 23:48:41 +03:00
Vitaliy Filippov 2f38adeb3d Restart dead VDUSE daemons at regular intervals 2023-12-24 12:58:50 +03:00
Vitaliy Filippov f72f14e6a7 Clear old PG states, history, and OSD states on etcd state reload
Also add protection from etcd watcher messages being split into multiple websocket
messages - I'm not sure if etcd actually does that, but it's better to have extra
protection anyway.

Also check that all etcd watchers are started in the keepalive routine, otherwise
it sometimes tries to revive etcd watchers starting with revision=1 which obviously
always fails because this revision is nearly always compacted.

All these changes should fix an old rarely reproduced bug where SOMETIMES OSDs
didn't react to PG config changes which was leading to offline pools on node reboot.
It happened on the full reload of state from etcd.
2023-12-24 02:02:13 +03:00
Vitaliy Filippov 1299373988 Use the same etcd_ws_keepalive_interval in OSD and mon 2023-12-23 20:07:29 +03:00
Vitaliy Filippov 178bb0e701 Prevent re-entry into timerfd set_nearest 2023-12-22 02:32:40 +03:00
Vitaliy Filippov 4ece4dfdd0 Fix mon not using values from config when /config/global is not present 2023-12-22 02:25:09 +03:00
Vitaliy Filippov 95631773b6 Remove pve-storage-portal-dns-list format for vitastor_etcd_address 2023-12-20 02:22:06 +03:00
Vitaliy Filippov 7239cfb91a Parse log_level in cluster_client 2023-12-20 02:21:23 +03:00
Vitaliy Filippov 7cea642f4a Fix vitastor-nbd image existence check not working because of non-zeroed inode_watch fields 2023-12-19 01:11:37 +03:00
Vitaliy Filippov dc615403d9 Do not warn on EPIPE in client unless log_level is raised explicitly 2023-12-17 13:42:26 +03:00
Vitaliy Filippov 1a704e06ab Allow multiple interfaces with the same IP address, for "simple routed" full mesh network 2023-12-17 13:25:56 +03:00
Vitaliy Filippov 575475de71 Do not ignore loopback addresses for OSD network (to make ECMP setups with frr possible) 2023-12-17 11:55:13 +03:00
Vitaliy Filippov aca2bef15f Add vitastor-disk update-sb command 2023-12-14 01:11:42 +03:00
Vitaliy Filippov 4dd6e89263 Change qemu to qemu-system-x86 in docs 2023-12-14 01:01:00 +03:00
Vitaliy Filippov 9bac99ffb6 Fix incorrect error in CSI when searching for the device in /sys 2023-12-14 01:00:32 +03:00
Vitaliy Filippov 62ed130960 Support building qemu 8.1 from bookworm-backports 2023-12-10 00:34:13 +03:00
Vitaliy Filippov 9c7755b6e8 Use qemu-storage-daemon from QEMU 8.1.2 for CSI 2023-12-08 00:10:12 +03:00
Vitaliy Filippov 691ebd991a Move 2 last log printfs to stderr from stdout in etcd_state_client 2023-12-08 00:01:52 +03:00
Vitaliy Filippov 6d5df908a3 Fix possible out of bounds when checking invalid journal entries 2023-12-08 00:01:07 +03:00
Vitaliy Filippov fa87769ed8 Correct config options in vduse docs 2023-12-06 02:09:04 +03:00
Vitaliy Filippov 2ce8292803 Also log when killing process 2023-12-06 01:06:53 +03:00
Vitaliy Filippov 7f8f7ded52 Check for empty output of vitastor-nbd map (just in case) 2023-12-06 01:01:14 +03:00
Vitaliy Filippov 68553eabbb Log executed CLI commands 2023-12-06 00:48:12 +03:00
Vitaliy Filippov 3147c5c8d5 Remove internal error wrapping 2023-12-06 00:39:42 +03:00
Vitaliy Filippov 576e2ae608 Fix etcd_address check in CSI 2023-12-06 00:28:21 +03:00
Vitaliy Filippov a1c7cc3d8d Release 1.3.1
Hotfix to 1.3.0 - new "journal space reservation" had a bug which
caused OSDs to crash with EC and without immediate_commit.
2023-12-04 18:35:09 +03:00
Vitaliy Filippov a5e3dfbc5a Oops, 1.3.0 needs a hotfix 2023-12-04 13:45:54 +03:00
Vitaliy Filippov 7972502eaf Release 1.3.0
New features:
- RDMA without ODP - much faster and all cards are now supported, not just Mellanox
- VDUSE in CSI - faster, more stable and can even recover after CSI pod restart!
- Reserve journal space for stabilize requests dynamically to prevent stalls under load with EC
- Raise default NBD timeout from 30 to 300 seconds and allow to take it from /etc/vitastor/vitastor.conf
- Remove explicit etcdUrl/etcdPrefix K8S storage class parameter support to prevent
  etcd migration issues for volumes created with these parameters
- Support QEMU 8.1 and pve-qemu 8.1

Bug fixes:
- Fix RDMA connection (and thus memory) leak
- Fix rare crashes under load due to incorrect io_uring queue size tracking
- Fix monitor statistics aggregation in case of empty /osd/stats keys
- Fix crash on unknown long argument to vitastor-disk
- Allow trailing comma in JSONs again
- Fix crash on attempts to dump a long listing of objects "to stabilize" or "to rollback" in a slow op
2023-12-04 02:36:43 +03:00
Vitaliy Filippov e57b7203b8 Use cmake3 on RHEL 7 2023-12-04 02:36:29 +03:00
Vitaliy Filippov c8a179dcda Note that Proxmox 8.1 is supported 2023-12-04 02:20:33 +03:00
Vitaliy Filippov 845454742d Fix warning with QEMU 8.1 2023-12-04 01:59:07 +03:00
Vitaliy Filippov d65512bd80 Add patches for QEMU 8.1 2023-12-04 01:56:17 +03:00
Vitaliy Filippov 53de2bbd0f Support VDUSE in CSI
VDUSE has multiple advantages:
- Better performance
- Lack of timeout problems
- And even the ability to recover after restart of the vitastor-csi pod!
2023-12-04 00:41:24 +03:00
Vitaliy Filippov 628aa59574 Raise default NBD timeout from 30 to 300 seconds and allow to take it from /etc/vitastor/vitastor.conf 2023-12-02 14:11:14 +03:00
Vitaliy Filippov 037cf64a47 Remove explicit etcdUrl/etcdPrefix from volume parameters 2023-12-02 13:26:00 +03:00
Vitaliy Filippov 19e2d9d6fa Fix crash on unknown long argument to vitastor-disk 2023-12-01 00:55:51 +03:00
Vitaliy Filippov bfc7e61909 Add more notes + performance comparison about VDUSE 2023-11-25 02:25:56 +03:00
Vitaliy Filippov 7da4868b37 Fix monitor statistics aggregation in case of empty /osd/stats keys 2023-11-24 01:05:21 +03:00
Vitaliy Filippov b5c020ce0b Use io_uring SQ size for ringloop capacity - otherwise get_sqe could return NULL when space_left() was > 0 under load
Raise default io_uring size to 1024 for the same effective capacity as previously
2023-11-20 03:04:06 +03:00
Vitaliy Filippov 6b33ae973d %d -> %lu 2023-11-20 03:02:26 +03:00
Vitaliy Filippov cf36445359 Reserve journal space for stabilize requests dynamically to prevent stalls 2023-11-20 03:01:57 +03:00
Vitaliy Filippov 3fd873d263 Add -fno-omit-frame-pointer by default 2023-11-20 02:59:54 +03:00
Vitaliy Filippov a00e8ae9ed Fix mismatch journal pos format in vitastor-disk 2023-11-19 15:19:54 +03:00
Vitaliy Filippov 75674545dc Limit the number of printed object versions in slow op dump (otherwise it may overflow the fixed buffer) 2023-11-13 01:10:28 +03:00
Vitaliy Filippov 225eb2fe3d Support RDMA without ODP by stupidly copying memory. Disable ODP by default
ODP is slower than regular RDMA even with memory copy overhead

Example numbers:
- 3950000 random read iops without ODP vs 240000 iops with ODP
- 1447000 random write iops without ODP vs 101000 iops with ODP

Reference: https://tkygtr6.github.io/pub/ISPASS21_slides.pdf
2023-11-12 15:03:47 +03:00
Vitaliy Filippov 7e82573ed0 Fix RDMA connection leak which was preventing stable functioning of RDMA :) 2023-11-11 23:40:47 +03:00
Vitaliy Filippov 12a6bed2d5 Return the new accidentally rolled back json11 commit ("allow trailing comma") 2023-11-07 15:49:23 +03:00
Vitaliy Filippov 5524dbdab7 Release 1.2.0
New features:

- Implement CSI volume expansion
- Implement CSI volume snapshots
- CSI driver now requires Kubernetes >= 1.20

Bug fixes:

- Important bug fix for EC: fix EC n+k, k>=2 read recovery in ISA-L version returning
  incorrect data when reading at least the second chunk out of multiple missing chunks
  without reading the first one. All users of EC n+k, k>=2 should upgrade as soon as
  possible, and upgrade should be conducted with downtime: first stop all clients
  (VMs/containers), then all OSDs, then upgrade and restart everything.
- Fix unstable statistics aggregation in monitor (affecting vitastor-cli status and df)
- Make udev not wait for OSDs to start during boot
- Do not report negative numbers of offline PGs in vitastor-cli status when changing PG count
- Report both old and new PG counts in vitastor-cli df when changing it
- Fix OSDs sometimes not starting with "The code only supports journal versions 1 and 2,
  but it is 2 on disk" error after upgrading from pre-1.0 versions and letting OSDs run
  for some time
- Fix monitors sometimes returning old PG count back after OSD configuration changes
- Make monitor PG changes more stable and timeout errors less probable
2023-11-05 01:48:57 +03:00
Vitaliy Filippov cd3dec06ac Remove spaces from old->new PG count in df 2023-11-05 01:45:45 +03:00
Vitaliy Filippov 371d79e059 Document vitastor-csi features 2023-11-05 01:05:26 +03:00
Vitaliy Filippov 0e888e6c60 Prevent spamming etcd with last_clean_pgs update requests 2023-11-05 00:12:00 +03:00
Vitaliy Filippov 408c21d8f0 Scale last_clean_pgs PG count even if current PGs already contain the new number of PGs 2023-11-04 23:45:59 +03:00
Vitaliy Filippov 43cb9ae212 Prevent multiple parallel recheck_pgs in case of timeouts 2023-11-04 20:59:56 +03:00
Vitaliy Filippov e15b6e7805 Fix "cannot be narrowed" in clang 2023-11-04 18:14:44 +03:00
Vitaliy Filippov 31017d8412 Allow to start with V2 journal with header size from V1, as incorrectly updated by previous versions 2023-11-04 18:13:42 +03:00
Vitaliy Filippov 4819854064 Fix OSDs incorrectly updating journal superblock after upgrade to 1.x from pre-1.x and refusing to start after it 2023-11-04 15:02:24 +03:00
Vitaliy Filippov 1f509cca77 Fix unused capture warnings and void* arithmetic (clang) 2023-11-04 14:55:12 +03:00
Vitaliy Filippov aa8e8e8271 Add version info to --help output 2023-11-04 13:32:12 +03:00
Vitaliy Filippov 4d79e531c5 Do not print "-X offline" in status when changing pool PG count, print it in df instead 2023-11-04 13:12:13 +03:00
Vitaliy Filippov 30dff8893f Fix ISA-L version EC recovery with first missing data chunk not being read
(Yes, all EC n + k with k >= 2 users should upgrade as soon as possible)
2023-11-04 01:34:18 +03:00
Vitaliy Filippov becf14a705 Add a test for EC with multiple missing data chunks, but without recovery of first of them 2023-11-04 01:34:18 +03:00
Vitaliy Filippov 64388788c1 Implement CSI volume expansion 2023-11-01 12:46:20 +03:00
Vitaliy Filippov 37653abe4b Implement CSI volume snapshots 2023-11-01 12:46:20 +03:00
Vitaliy Filippov 7c054c6f10 Add "id" to df --json output 2023-11-01 12:46:16 +03:00
Vitaliy Filippov bb7709e824 Support listening on non-127.0.0.1 in tests 2023-11-01 12:45:27 +03:00
Vitaliy Filippov ebeace5a2d Add cmake and pkg-config to debian build depends 2023-11-01 12:45:27 +03:00
Vitaliy Filippov a378789f10 Rollback erroneous go.mod changes in 1.1.0 O:-) 2023-10-30 18:47:48 +03:00
Vitaliy Filippov 1fe678e57b Add --no-block to udev rule 2023-10-30 12:18:29 +03:00
Vitaliy Filippov 2e592a2f22 Fix undefined variable "timeout" 2023-10-29 01:30:55 +03:00
Vitaliy Filippov b92f644e3a Fix statistics aggregation, calculate inode stats by first deriving per-OSD stats, too 2023-10-29 01:30:55 +03:00
Vitaliy Filippov 890ea3dbc0 Forgot to add new parameter page to README 2023-10-28 13:39:53 +03:00
Vitaliy Filippov 06630369bf Plans++ 2023-10-28 13:38:04 +03:00
Vitaliy Filippov b4740acf62 Fix operations paused for 0.5-1 second when it happens that io_uring submit is not triggered 2023-10-28 13:18:21 +03:00
Vitaliy Filippov eae81bbda6 Fix typo 2023-10-28 01:09:20 +03:00
Vitaliy Filippov 8222e3c77d Release 1.1.0
New features:

- Implement [client writeback cache](docs/config/client.en.md#client_enable_writeback)
- Add the third I/O mode: [O_DIRECT|O_SYNC](docs/config/osd.en.md#data_io) (good for Optane)
- Reduce load on etcd by splitting OSD lease and statistics reporting intervals:
  [etcd_stats_interval](docs/config/osd.en.md#etcd_stats_interval) (default 30 sec)
- Make MON automatically filter OSDs by layout (block_size/immediate_commit/bitmap_granularity)
  to prevent "refusing to start PGs of this pool" errors on misconfiguration
- Support running fio benchmarks on systems without io_uring
- Make QEMU driver compatible with QEMU 8.1
- Document usage of [vhost-user-blk](docs/usage/qemu.en.md#vhost-user-blk)

Bug fixes:

- Fix resizing disks in QEMU driver (for example, in Proxmox)
- Fix "unexpected result" in Proxmox driver by making CLI flush output on exit
- Remove unneeded block_size mismatch warnings on pools without matching PGs
- Fix possible segfault in vitastor-cli ls -l (usually with deleted pools)
- Fix QEMU driver compatibility with systems without io_uring
- Fix monitor eating 100% CPU when etcd is down (caused by infinite retries)
- Fix potential incorrect write processing with snapshots (not caught in tests
  but could probably lead to client hangs)
- Fix buffer insertion in cluster_client (not caught in tests but could
  probably lead to incorrect writes in rare cases)
- Fix rare OSD crash during sync operation processing
- Fix a reenterability issue in cluster_client not reproducible in QEMU/fio,
  but reproducible with the currently developed K/V database implementation
- Fix deletion of the first modified object - OSDs could crash if you modified
  the same object a lot of times, then deleted it, and then modified it again
- Fix the fio_sec_osd test tool
2023-10-28 00:33:06 +03:00
Vitaliy Filippov 29cbe70e74 Bump qemu version to vitastor4 2023-10-28 00:33:06 +03:00
Vitaliy Filippov a883e79507 Make docs to add etcd_stats_interval 2023-10-27 14:09:26 +03:00
Vitaliy Filippov be7e76f849 Split etcd_stats_interval out of etcd_report_interval 2023-10-27 01:26:26 +03:00
Vitaliy Filippov 6fd2cf5df6 Add documentation for the write-back cache 2023-10-27 01:26:26 +03:00
Vitaliy Filippov 294a754c9e Allow write-back by default in NBD & NFS 2023-10-27 01:26:26 +03:00
Vitaliy Filippov 8bfea6e7de Support vitastor_c_create_epoll() in fio driver 2023-10-26 22:57:36 +03:00
Vitaliy Filippov bac9e34836 Allow to create vitastor_c with plain epoll without uring :-) 2023-10-26 22:57:36 +03:00
Vitaliy Filippov 8aa4d492c1 Allow to use epoll_manager without ringloop 2023-10-26 22:57:36 +03:00
Vitaliy Filippov 9336ee5476 Correctly free manual "small vector" in cluster_client %-) 2023-10-26 22:57:36 +03:00
Vitaliy Filippov ad30b11519 Add the missing ringloop creation check to vitastor_c_create_uring_json() 2023-10-26 18:07:23 +03:00
Vitaliy Filippov a061246997 Do not attempt to initialize QEMU driver via vitastor_c_create_qemu_uring()
It doesn't add any compatibility because vitastor_c_uring_register_eventfd()
is added in the same VITASTOR_C_API_VERSION 2.
2023-10-26 17:46:19 +03:00
Vitaliy Filippov 5066e35a49 Fix write-over-delete failing for the very first entry in dirty_db 2023-10-21 17:00:14 +03:00
Vitaliy Filippov 93dc31f3fc Fix possible segfault in vitastor-cli ls -l 2023-10-18 11:11:41 +03:00
Vitaliy Filippov f245b56176 Fix another possible reenterability issue in cluster_client
Non-reproducible in QEMU/FIO, only caught during K/V DB debugging
2023-10-08 11:02:53 +03:00
Vitaliy Filippov befca06f18 Support any OSD count in test_heal 2023-10-08 11:02:53 +03:00
Vitaliy Filippov fbf0263625 Add qemu-storage-daemon to documentation 2023-09-16 18:40:52 +03:00
Vitaliy Filippov 3bcf276d4d Run tests with writeback 2023-09-16 17:52:17 +03:00
Vitaliy Filippov 38db53f5ee Implement client writeback cache
- Disabled by default, enable with client_enable_writeback=true
- Even then only enabled in FIO when -direct is disabled and in QEMU when
  block device cache is enabled in settings
- Can also be enabled in other clients like vitastor-cli using parameter
  client_writeback_allowed=true, but not recommended
2023-09-16 17:52:17 +03:00
Vitaliy Filippov cd543a90bc Prevent stack overflows in cli_merge with CAS and writeback cache 2023-09-16 17:52:17 +03:00
Vitaliy Filippov f600cc07b0 Autosync in blockstore every autosync_writes, too 2023-09-16 17:52:17 +03:00
Vitaliy Filippov 6a8e530e6b Add FIXME to timerfd_manager 2023-09-16 17:52:17 +03:00
Vitaliy Filippov 5cadb170b9 Fix possible OSD crash during sync due to missing min_flushed_journal_sector reset 2023-09-16 17:52:17 +03:00
Vitaliy Filippov e72d4ed1d4 Remove unused bs_sync fields 2023-09-16 17:52:17 +03:00
Vitaliy Filippov ff479a102d Make MON filter OSDs by block layout to prevent "refusing to start PGs of this pool" errors on misconfiguration 2023-09-16 17:52:17 +03:00
Vitaliy Filippov 27d0d5b06a Reads do not have to wait for buffer flushes anymore 2023-09-16 17:52:17 +03:00
Vitaliy Filippov 33950c1ec8 Fix fio_sec_osd attr_len 2023-09-16 17:49:10 +03:00
Vitaliy Filippov eea7ef1f19 Remove debug osd_trace from test_write 2023-09-12 01:35:36 +03:00
Vitaliy Filippov cc0fdc6253 Remove erroneous block_size mismatch warnings on pools without matching PGs 2023-09-08 23:19:04 +03:00
Vitaliy Filippov 79ecd59b10 Flush STDOUT and STDERR before exiting from cli to fix Proxmox "Unexpected result" 2023-09-07 17:30:26 +03:00
Vitaliy Filippov 51081c9b45 Put etcd into tmpfs for tests 2023-09-07 02:35:09 +03:00
Vitaliy Filippov b7d398be5b Fix sscanf validation usage (field count instead of null_byte == 0) 2023-09-07 02:34:35 +03:00
Vitaliy Filippov 85e9f67d9d Add supported_truncate_flags 2023-09-06 17:37:52 +03:00
Vitaliy Filippov 79c6d6f323 Make QEMU driver compatible with QEMU 8.1 2023-08-24 02:23:55 +03:00
Vitaliy Filippov ae760dbc1d Fix co_truncate size division by BDRV_SECTOR_SIZE 2023-08-24 01:55:35 +03:00
Vitaliy Filippov 65487da4b1 Do not include msgr_rdma.h into messenger.h 2023-08-24 01:55:35 +03:00
Vitaliy Filippov 7862282938 Extract validation to check_rw(), remove duplicate code with OP_SYNC 2023-08-13 23:49:52 +03:00
Vitaliy Filippov 30ce2bd951 Fix buffer insert in cluster_client 2023-08-12 11:08:50 +03:00
Vitaliy Filippov b1a0afd10a Aggregate buffer flushes 2023-08-11 11:26:13 +03:00
Vitaliy Filippov 85b6134910 Return dirty buffers on read in client
Required at least to return buffers when they need to be replayed, but until
they are actually replayed
2023-08-09 00:57:08 +03:00
Vitaliy Filippov b1b07a393d Fix incorrect marking op parts as done with snapshots (could probably lead to client hangs) 2023-08-09 00:57:08 +03:00
Vitaliy Filippov 7333022adf Add a third I/O mode: O_DIRECT|O_SYNC, change parameters to data_io/meta_io/journal_io 2023-08-09 00:57:08 +03:00
Vitaliy Filippov ab8627c9fa Fix monitor retrying failed etcd connection in an infinite loop without pauses 2023-08-09 00:57:08 +03:00
Vitaliy Filippov 6acf562e01 Release 1.0.0
New features:

- Data and metadata checksums!
  - Metadata checksums are always used with new disk format
  - Data checksums can be turned on with --data_csum_type crc32c for new OSDs
  - Checksum block size can be configured
  - inmemory_metadata now also affects keeping checksums in memory
- Linux page cache I/O caching support which can be enabled separately for
  data, metadata (including checksums) and journal (O_SYNC instead of O_DIRECT)
- Details [here](https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/docs/config/layout-osd.en.md#data_csum_type)
- Backwards compatibility is preserved, you can use new OSDs with old disks

Release also includes bug fixes from [0.9.6](https://git.yourcmc.ru/vitalif/vitastor/releases/tag/v0.9.6).

0.9.6 is moved to "-oldstable" repositories and will be available for some additional time.
2023-07-29 18:57:19 +03:00
Vitaliy Filippov 6f797f429e Add a note about -oldstable 2023-07-29 18:11:13 +03:00
Vitaliy Filippov b8a1734465 Reword checksum docs one more time 2023-07-29 14:42:56 +03:00
Vitaliy Filippov c752b68167 Remove "without checksums" from docs :) 2023-07-29 12:19:03 +03:00
Vitaliy Filippov 564df2eb5d Support using buffered I/O with O_SYNC instead of direct I/O 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 9a427dd70a Allow to override OSD devices in tests 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 1a4ceb420d Track used blocks, not object versions 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 21b5124a4b Document data_csum_type and csum_block_size parameters 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 4181add1f4 Remove creepy "metadata copying" during overwrite
Instead of it, just do not verify checksums of currently mutated objects.
When clean data modification during flush runs in parallel to a read request,
that request may read a mix of old and new data. It may even read a mix of
multiple flushed versions if it lasts too long... And attempts to verify it
using temporary copies of metadata make the algorithm too complex and creepy.
2023-07-29 12:17:18 +03:00
Vitaliy Filippov a8464c19af Support keeping checksums on disk (not in memory)
Definitely beneficial for SSD+HDD setups
2023-07-29 12:17:18 +03:00
Vitaliy Filippov 819cb70cdd Check for "Checksum mismatch" and "BUG" messages during test_heal 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 3c8e4c6b72 Use clean_dyn_size for space check 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 8ef4cf89dc Log more details about checksum mismatch in big_writes 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 7bfb1639ea Use find_holes() in flusher for unification 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 628e481c32 Fill journal header to know checksum type & size when dumping journal with --all 2023-07-29 12:17:18 +03:00
Vitaliy Filippov af6f2046fc Fix journal read checksum verification with inmemory_journal=false 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 9357e5293e Call fill_partial_checksum_blocks() correctly in regard to COPY_BUF_CSUM_FILL 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 12851dc07d Wait for journal reads before checking them in clear_incomplete_csum_block_bits 2023-07-29 12:17:18 +03:00
Vitaliy Filippov a5753e35a3 Check for checksum mismatch absence in test_heal 2023-07-29 12:17:18 +03:00
Vitaliy Filippov d6ee1ca17c Use zero checksum size for zero-length writes 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 71674d00cf Fix journal data checksum mangling on corrupted block overwrite 2023-07-29 12:17:18 +03:00
Vitaliy Filippov ddb078d5a7 Check journal entry size when checking block checksums 2023-07-29 12:17:18 +03:00
Vitaliy Filippov d22d56f90a Fix journal data checksum verification on start 2023-07-29 12:17:18 +03:00
Vitaliy Filippov eb1331a079 Add more details to "journal entry data is corrupt" messages 2023-07-29 12:17:18 +03:00
Vitaliy Filippov c5274f655b ...and partially remove the perversion with bitmap inlining 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 45e07d6294 Sadly we have to refcount dyn_data... 2023-07-29 12:17:18 +03:00
Vitaliy Filippov a8ee391e05 Fix clean block checksum read 2023-07-29 12:17:18 +03:00
Vitaliy Filippov de48fa3fd2 Allow to forcibly set meta_format 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 874a766b62 Rename meta_version to meta_format 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 384bd8e28f Support old metadata format in vitastor-disk dump-meta 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 430994f48a Fix journal big_write simple reads after checksum changes 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 3d7f838c59 Verify checksums in test_heal in different combinations 2023-07-29 12:17:18 +03:00
Vitaliy Filippov b909d81f41 Fix bitmap-granular checksums 2023-07-29 12:17:18 +03:00
Vitaliy Filippov e42975ffd1 Fix wait_journal_count not being zeroed 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 93778324e5 Rewrite and fix find_holes into a more obvious version 2023-07-29 12:17:18 +03:00
Vitaliy Filippov eeb6727170 Fix missing checksum read offset 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 7fe82c692e Add a test for checksums 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 92c6e16eba Fix checksum verification in big_write journal reads 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 213a9ccb4d Verify checksums during journal reads 2023-07-29 12:17:18 +03:00
Vitaliy Filippov a166147110 Add backwards compatibility with non-checksum metadata and journal formats 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 7d532880c3 Implement large csum_block_size support (more than 4k) + refactor blockstore_flush 2023-07-29 12:17:18 +03:00
Vitaliy Filippov 0b0405d115 Implement bitmap-granular (4k) metadata & data checksums 2023-07-29 12:17:18 +03:00
Vitaliy Filippov e651c93a90 Release 0.9.6
- Fix vitastor-disk partition zeroing (sometimes it was writing garbage instead of zeroes)
- Fix incorrect EC space statistics in `vitastor-cli status`
- Several bug fixes for NFS:
  - Add . and .. in NFS directory listings
  - Return FILE_SYNC from NFS writes if immediate_commit is enabled
  - Return the same "verifier" in NFS COMMIT as in NFS WRITE
  - Make parallel NFS extending writes work correctly, without conflicts
  - Handle parallel NFS extending writes without imposing extra load on etcd
- Support UTF-8 in vitastor-cli table output
- Also allow "0" and "no" as false for inmemory_metadata and inmemory_journal
- Use HDD defaults for HDD-only in automatic `vitastor-disk prepare` mode
2023-07-29 10:54:00 +03:00
Vitaliy Filippov 988e90be69 Fix vitastor-disk partition zeroing (it was writing random garbage instead of zeroes :D) 2023-07-28 12:29:07 +03:00
Vitaliy Filippov 272a45ad63 Fix modprobe command in docs 2023-07-27 23:57:02 +03:00
Vitaliy Filippov 25a15d24cf Fix incorrect EC space statistics in `vitastor-cli status` 2023-07-27 02:26:17 +00:00
Vitaliy Filippov 700e0e9bff Handle parallel NFS extending writes without imposing extra load on etcd 2023-07-27 02:26:17 +00:00
Vitaliy Filippov ab0ca7c00f Return FILE_SYNC from NFS writes if immediate_commit is enabled 2023-07-26 02:09:47 +03:00
Vitaliy Filippov f153bc950b Return the same "verifier" in NFS COMMIT as in NFS WRITE
This fixes buffered (not O_DIRECT) NFS writes in Linux - previously they were
hanging in an infinite loop because COMMIT didn't return the same verifier as
previous WRITEs, and NFS kernel client was infinitely retrying the same writes.

Also this probably allows for correct NFS failover, at least for the same
buffered writes, because NFS clients repeat all write requests until a COMMIT
confirms them.
2023-07-26 02:09:47 +03:00
Vitaliy Filippov 425ff8818d Add . and .. in NFS directory listings
MC, for example, hangs with infinite listing retries without them
2023-07-26 02:09:47 +03:00
Vitaliy Filippov 9e287a7778 Handle extending writes correctly in NFS proxy
Previously, multiple parallel writes extending file size through NFS were
racing with each other and triggering deletions of part of the written data

I.e. if you mounted vitastor-nfs and just copied a file into it in MC then
you could end up with only a part of the file actually written
2023-07-26 02:09:43 +03:00
Vitaliy Filippov f52f58b9e9 Support UTF-8 in vitastor-cli table output 2023-07-25 01:48:57 +00:00
Vitaliy Filippov 1fe6b0c0e2 Also allow "0" and "no" as false for inmemory_metadata and inmemory_journal 2023-07-25 01:48:57 +00:00
Vitaliy Filippov e4237e9ed8 Enable HDD defaults for HDD-only in automatic `vitastor-disk prepare` mode 2023-07-23 02:33:22 +03:00
Vitaliy Filippov 10a5fd6abb Release 0.9.5
A hotfix to 0.9.4 containing only one bugfix: 100% CPU usage in the new QEMU
driver caused by the lack of eventfd reset on io_uring event handling :)
2023-07-21 00:04:41 +03:00
Vitaliy Filippov 1c316ef350 Reset eventfd on every ringloop::loop() 2023-07-21 00:04:41 +03:00
Vitaliy Filippov 0b2d12eef1 Remove has_work, it was unnecessary 2023-07-21 00:04:37 +03:00
Vitaliy Filippov 1c10430ae1 Release 0.9.4
- Improve QEMU driver performance by integrating io_uring in it (up to 1.5x total iops improvement)
- Fix QEMU driver deadlocks which started to reproduce in qemu-img after iothread fixes
- Fix `vitastor-cli status` reporting more etcds than actually exists (fix etcd address duplication in config on reload)
- Fix `vitastor-cli ls` crashing on inodes in non-existing pools
- Delete old garbage /pool/stats/ keys for non-existing (deleted) pools
- Reduce memory usage of etcds initialized by make-etcd script
- Fix OSDs almost always crashing on etcd restart due to "revisions were compacted" (support reloading state from etcd)
- Fix a crash and a stall possible mostly in HDD setups with small journal and big (512k, 900k) random writes
- Add notes about HDDs to documentation. You are officially allowed to use HDD-only Vitastor with HGST/Toshiba/EXOS :)
2023-07-19 02:50:30 +03:00
Vitaliy Filippov dfce91d168 Change git url in docs, correct block/vitastor.c path 2023-07-19 01:02:12 +03:00
Vitaliy Filippov 332a13ba30 Build patched QEMU against local packages 2023-07-19 00:05:02 +03:00
Vitaliy Filippov d0e257ee81 Fix non-existing pool handling in `vitastor-cli ls` 2023-07-18 23:52:02 +03:00
Vitaliy Filippov 004912aac0 Add RPM spec patches for 6.2-el8 and 7.2-el9 2023-07-18 23:38:14 +03:00
Vitaliy Filippov c18e92273e Copy qemu 5.1 -> 5.2 patch for convenience 2023-07-18 23:37:53 +03:00
Vitaliy Filippov 9815d70ffc It is impossible to use io_uring with older vitastor-client because it does not have vitastor_c_uring_has_work() 2023-07-18 23:37:53 +03:00
Vitaliy Filippov 4a4627dcab Do not use bool in C library 2023-07-18 23:37:53 +03:00
Vitaliy Filippov b963f2fd93 Add QEMU 2.12 patch (basically the same as 3.1) 2023-07-18 23:37:06 +03:00
Vitaliy Filippov ba7427020e Fix deadlocks possible in qemu-img after fixing iothread
Deadlock was caused by switching QEMU coroutines directly inside
vitastor_co_read_bitmap_cb() callback. The correct way is to schedule a BH
/BH is a QEMU term for setImmediate() :)/, same as in read and write callbacks.
2023-07-18 23:32:16 +03:00
Vitaliy Filippov a0aac7eb2a Update drives 2023-07-13 01:49:45 +03:00
Vitaliy Filippov ac7b834af3 Disable journal_no_same_sector_overwrites by default for HDD-only 2023-07-10 00:34:35 +03:00
Vitaliy Filippov ee0c78fd74 Fix default HDD block size in docs (actual size is 1 MB) 2023-07-09 13:12:30 +03:00
Vitaliy Filippov e6646a5b2f Bump QEMU version to vitastor3 2023-07-09 13:01:04 +03:00
Vitaliy Filippov ae69662b17 Add "Recommended drives" 2023-07-09 12:59:18 +03:00
Vitaliy Filippov 57ad4c3636 Add a note about HDD, enable throttling only for hybrid OSDs 2023-07-09 12:45:11 +03:00
Vitaliy Filippov b7e4d0c9bf Fix journal dirty_start position tracking and some debug prints
Fixes two bugs found during HDD testing :-)
1) OSD crashed with "BUG: Attempt to overwrite used offset of the journal" during
   `fio -bs=900k -iodepth=128` test with 16 MB journal
2) OSD stalled during `fio -bs=512k -iodepth=128` test with 64 MB journal
2023-07-09 01:17:55 +03:00
Vitaliy Filippov 161a23c966 Support reloading state when etcd says "revisions were compacted"
Before this change, OSDs almost always died when one of the etcds was restarted,
even though the rest of them was still in quorum and the lease was still active
2023-07-07 01:33:48 +03:00
Vitaliy Filippov 2f999d8607 Reduce etcd memory usage
With default --snapshot-count 100000 and GOGC=100 it easily reaches 6.6 GB
even when we only store 1-2 MB of data in it
2023-07-06 00:46:26 +03:00
Vitaliy Filippov d007a374f2 Delete extra /pool/stats/ keys for non-existing pools 2023-07-06 00:40:13 +03:00
Vitaliy Filippov 45c0694853 Clear etcd_local addresses on reload and also skip duplicates 2023-07-06 00:39:39 +03:00
Vitaliy Filippov 57bcba2406 Add notes about VDUSE 2023-07-04 16:51:46 +03:00
Vitaliy Filippov 30ac899074 Make QEMU driver compatible with older vitastor_client and with systems without io_uring 2023-07-04 15:51:43 +03:00
Vitaliy Filippov 2348d39cf4 Avoid repeated qemu_uring_handlers, add 2.0-2.7 compatibility 2023-07-04 00:28:23 +03:00
Vitaliy Filippov 3de7929fe5 Integrate v2 - direct epoll 2023-07-04 00:28:23 +03:00
Vitaliy Filippov 07b2196bc2 Integrate QEMU driver with io_uring 2023-07-04 00:28:23 +03:00
Vitaliy Filippov b8e30608d6 Bump QEMU version to vitastor2 2023-07-01 00:55:32 +03:00
Vitaliy Filippov a612cdca47 Release 0.9.3
- Add patch for libvirt 9.0
- Add support for Proxmox VE 8.0
- Fix compatibility of the QEMU driver with iothread (QEMU rebuilds are coming)
- Fix vitastor-cli rm-data/rm/merge hanging when some OSDs are down.
  Allow deletions in unclean cluster at the cost of some data possibly
  "reappearing" when those OSDs start back. In that case you can just repeat
  the deletion request using rm-data.
- A bunch of bug fixes for snapshots:
  - Fix snapshot reads often not working at all with snapshot chain size > 2
  - Fix optimized snapshot data merge (children to parent)
  - Fix updating of image name index key during optimized merge
  - Fix auto-selection preventing the use of optimized merge with only 1 snapshot
  - Fix incorrect CAS retries during snapshot merge
  - Fix snapshot merge progress reporting
- Fix primary_read bitmap buffers use-after-free which could lead to
  incorrect allocation map reads
- Remove /usr/local/bin path from make-etcd
- Some documentation fixes
2023-07-01 00:25:58 +03:00
Vitaliy Filippov c8d61568b5 Fix primary_read bitmap buffers being freed too early (use-after-free) 2023-06-30 12:47:45 +03:00
Vitaliy Filippov 84ed3c6395 Fix CAS retries during snapshot merge 2023-06-30 02:30:23 +03:00
Vitaliy Filippov a7b57386c0 Do not print last subcommand result twice during "inverse" snapshot merge 2023-06-30 02:07:10 +03:00
Vitaliy Filippov 9d4ea5f764 Fix inverse parent selection which prevented the use of optimized merge in case of only 1 snapshot 2023-06-30 01:39:11 +03:00
Vitaliy Filippov 000e4944ec Remove "inverse parent" image name index key from etcd during snapshot merge 2023-06-30 01:23:30 +03:00
Vitaliy Filippov 8426616d89 Warn about unfinished deletions in rm-data 2023-06-30 01:18:25 +03:00
Vitaliy Filippov 1a841344ec Print progress of all operations during snapshot merge 2023-06-30 01:13:47 +03:00
Vitaliy Filippov 8603b5cb1d Do not hang on inactive OSDs during delete, report and skip them instead 2023-06-30 00:15:16 +03:00
Vitaliy Filippov f12b8e45a9 Remove /usr/local/bin path from make-etcd 2023-06-29 23:49:31 +03:00
Vitaliy Filippov 878ccbb6ea Fix snapshot chain "down-merge" ("up-merge" worked well...) 2023-06-29 00:47:21 +03:00
Vitaliy Filippov b14220b4d0 Add a test for snapshot chain 2023-06-29 00:47:21 +03:00
Vitaliy Filippov 181d6ba407 Move npm install to CI build and remove it from tests 2023-06-28 23:41:46 +03:00
Vitaliy Filippov 63c2b9832c Fix chained (snapshot) reads often not working at all with chain size > 2 2023-06-28 18:54:03 +03:00
Vitaliy Filippov 10e2e6a7c8 Add a patch for pve-qemu 8.0 2023-06-24 01:33:52 +03:00
Vitaliy Filippov a598428992 Add a note about PVE 8.0 2023-06-24 01:29:28 +03:00
Vitaliy Filippov 08a677b684 Notes about rebuilding pve-qemu 2023-06-24 01:00:21 +03:00
Vitaliy Filippov 7c8fbdad16 Fix typo 2023-06-22 02:07:33 +03:00
Vitaliy Filippov 2f9353df60 Markdown preprocessor to compile multiple .md files into one 2023-06-22 01:27:38 +03:00
Vitaliy Filippov 57c744f288 Fix some cross-references in docs 2023-06-22 01:16:03 +03:00
Vitaliy Filippov a11ca56fb1 Fix compatibility of the QEMU driver with iothread 2023-06-21 02:11:28 +03:00
Vitaliy Filippov b84927b340 Fix \n in nbd_proxy 2023-06-19 01:48:58 +03:00
Vitaliy Filippov 83cacba226 Fix patched-qemu build 2023-06-19 01:47:55 +03:00
Vitaliy Filippov 2c8f0bc6d5 Add a note about Debian 12 2023-06-19 01:08:41 +03:00
Vitaliy Filippov 7ae5b0e368 Add patch for libvirt 9.0 2023-06-19 01:07:08 +03:00
Vitaliy Filippov 926be372fd Release 0.9.2
- Measure and report scrub I/O statistics in vitastor-cli status
- Make aggregated statistics in vitastor-cli status much smoother
  (first derive, then sum instead of first summing and then deriving)
- Fix an old rare bug leading to journal corruption
  (try to use scrub if you think you're affected...)
- Do not start EC PGs without at least <data chunks> OSDs in each old set
  (prevents spurious read errors with EC during reconnections/restarts)
- Fix failed assert(!scrub_list_op) on OSD restart with pending scrubs
- Fix future planned scrubs not starting because of incorrect time comparison
- Build packages for Debian 12 (Bookworm)
2023-06-18 19:44:33 +03:00
Vitaliy Filippov 6222779b52 Support debian bookworm (12) build 2023-06-18 19:44:33 +03:00
Vitaliy Filippov a4186e20aa First derive, then sum per-OSD statistics instead of first summing and then deriving
This makes statistics reported by vitastor-cli status much smoother
2023-06-18 01:32:24 +03:00
Vitaliy Filippov c74a424930 Report scrub I/O in vitastor-cli status 2023-06-17 21:11:21 +03:00
Vitaliy Filippov 32f2c4dd27 Measure scrub statistics 2023-06-17 20:56:26 +03:00
Vitaliy Filippov 3ad16b9a1a Fix auto_scrubs not starting because of < vs <= =)) 2023-06-17 17:32:21 +03:00
Vitaliy Filippov 1c2df841c2 Fix failed assert(!scrub_list_op) on OSD restart with pending scrubs 2023-06-17 17:02:54 +03:00
Vitaliy Filippov aa5dacc7a9 Do not start EC PGs without at least pg_data_size connections to old OSDs from each set 2023-06-17 02:16:30 +03:00
Vitaliy Filippov affe8fc270 Raise timeout also for add_osd and rebalance_verify 2023-06-17 00:29:03 +03:00
Vitaliy Filippov 4fdc49bdc7 Add another assert-type check (it does not fire, just as a safety measure for the future) 2023-06-17 00:07:22 +03:00
Vitaliy Filippov 86b4682975 Put get_trim_pos into the "critical section". Fixes rare journal corruption issue
The consequence of this issue was that in some very rare cases (only reproduced
under load in CI when running 4+ tests in parallel) small write data written to
journal could overwrite journal entries.

Also add an assert-type safety check to be able to catch this issue in the
future again in case of a regression.
2023-06-17 00:06:42 +03:00
Vitaliy Filippov bdd48e4cf1 Release 0.9.1
- Fix "Client XX command out of sync" messages sometimes happening on OSD reconnections
- Fix a bug where EC reads parallel with writes to the same object failed with -ERANGE error
- Slightly reduce the amount of metadata writes during journal flushing
- Correctly unmap NBD volumes when Proxmox forces map_volume use (with SWTPM and maybe some other cases)
2023-06-10 11:42:49 +03:00
Vitaliy Filippov af8c3411cd Correctly unmap NBD when Proxmox forces map_volume use (with SWTPM and maybe something else) 2023-06-08 01:31:49 +03:00
Vitaliy Filippov 9c405009f3 Use randrw in test_heal 2023-06-03 00:49:53 +03:00
Vitaliy Filippov f9fbea25a4 Remove double write when old and new locations are in the same metadata block
Also add another metadata entry fool-safety check which, ideally, will never fire %)
2023-06-03 00:47:10 +03:00
Vitaliy Filippov 2c9a10d081 Fix an idiotic bug leading to failed reads with -ERANGE with EC :D 2023-06-03 00:44:52 +03:00
Vitaliy Filippov 150968070f Slightly improve some debug prints 2023-05-29 01:04:16 +03:00
Vitaliy Filippov cdfc74665b Close client FDs only when destroying the client, after handling all async reads/writes
Fixes "Client XX command out of sync" sometimes happening on reconnections
2023-05-25 00:52:43 +03:00
Vitaliy Filippov 3f60fecd7c Fix typo 2023-05-21 18:37:01 +03:00
Vitaliy Filippov 3b4cf29e65 Release 0.9.0
New features:
- Scrubbing! Check documentation: [auto_scrub](src/branch/master/docs/config/osd.en.md#auto_scrub)
- Document online-updatable configuration parameters

Bug fixes:
- Fix NaN during PG optimisation if there are nonexisting OSDs in node_placement
- Fix monitor crash on pool deletion
- Clear journal_device and meta_device before initialising the next OSD in automatic mode
- Sync unsynced deletes before overwriting them with a lower version
  (reproducted mostly/only after scrubbing)
2023-05-21 15:07:14 +03:00
Vitaliy Filippov eeaba11ebd Use fio 3.27-8 for alma9 2023-05-21 14:48:26 +03:00
Vitaliy Filippov aea567cfbd Slightly improve scrub docs 2023-05-21 12:52:30 +03:00
Vitaliy Filippov ce02f47de6 Allow to disable scrub_find_best 2023-05-21 12:33:38 +03:00
Vitaliy Filippov 5fd3208616 Add version archive link to docs 2023-05-21 11:47:33 +03:00
Vitaliy Filippov 5997b76535 Remove -runtime=10 from fio params in test_scrub, it was breaking the test in CI :D 2023-05-21 11:03:59 +03:00
Vitaliy Filippov f1961157f0 Fix brute-force error locator for EC n+k with k > 2 2023-05-21 00:57:14 +03:00
Vitaliy Filippov 88c1ba0790 Fix compile errors with gcc 10 2023-05-20 23:20:09 +03:00
Vitaliy Filippov b5bd611683 Add scrub tests to CI 2023-05-20 23:20:09 +03:00
Vitaliy Filippov fa90b5a4e7 Schedule automatic scrubs correctly (not just after previous scrub) 2023-05-20 23:20:09 +03:00
Vitaliy Filippov 8d40ad99a6 Add scrub documentation 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 3475772b07 Add configuration online update documentation 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 25fcedf6e7 Enable vitastor-cli fix in test 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 6ca20aa194 Allow scrub to fix corrupted object states 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 4bfd994341 Sync unsynced deletes before overwriting them with a lower version 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 59e959dcbb Do not die when "different versions are returned from subops" 2023-05-20 23:19:39 +03:00
Vitaliy Filippov a9581f0739 Handle dirty deletes during read correctly O_o 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 105a405b0a Implement vitastor-cli fix 2023-05-20 23:19:39 +03:00
Vitaliy Filippov d55d7d5326 Add scrub test 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 0e5d0e02a9 Add "vitastor-cli describe" command 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 0439981a66 Implement "describe object(s)" operation
Required to implement fixing inconsistent objects in vitastor-cli
2023-05-20 23:19:39 +03:00
Vitaliy Filippov 6648f6bb6e Implement ambiguity detection during scrub 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 281be547eb Implement brute-force error locator for EC 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 0c78dd7178 Add no_scrub flag 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 3c924397e7 Store next scrub timestamp instead of last scrub timestamp 2023-05-20 23:19:39 +03:00
Vitaliy Filippov c3bd26193d Implement PG scrub runner 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 43b77d7619 Implement scrubbing "data path" - OSD_OP_SCRUB 2023-05-20 23:19:39 +03:00
Vitaliy Filippov a6d846863b Add min/max stripe and limit to OP_LIST 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 8dc427b43c Retry failed reads (including chained and RMW) from other replicas 2023-05-20 23:19:39 +03:00
Vitaliy Filippov bf2112653b Refcount object_states 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 0538a484b3 Add corrupted object state 2023-05-20 23:19:39 +03:00
Vitaliy Filippov 97720fa6b4 Remove unused capture 2023-05-20 22:58:51 +03:00
Vitaliy Filippov e60e352df6 Improve vitastor-nbd documentation 2023-05-20 22:58:51 +03:00
Vitaliy Filippov 98077a1712 Remove unused dependencies from CSI 2023-05-18 11:54:47 +03:00
Vitaliy Filippov 1c7d53996d Reweight only 2 OSDs to zero in test_rebalance_verify, otherwise the test does not pass with EC 3+2 2023-05-18 00:42:40 +03:00
Vitaliy Filippov 2ca07b1ea7 Raise timeout in test_rebalance_verify 2023-05-17 01:58:01 +03:00
Vitaliy Filippov 022176aa98 Fix NaN during PG optimisation if there are nonexisting OSDs in node_placement 2023-05-17 01:20:30 +03:00
Vitaliy Filippov 120e3fa7bc Fix pool deletion 2023-05-17 00:45:59 +03:00
Vitaliy Filippov 629999f789 Clear journal_device and meta_device before initialising the next OSD in automatic mode 2023-05-15 23:58:55 +03:00
Vitaliy Filippov 93eca11ba2 Fix rhel 9 installation docs 2023-05-15 13:09:18 +03:00
Vitaliy Filippov 5a9e1ede52 Release 0.8.9
- The tests are now stable and run in a CI system based on Gitea CI
- The release includes final bug fixes for EC:
  - Implement missing EC recovery of allocation bitmap when built with ISA-L
  - Fix broken snapshot export with EC (allocation bitmap reads were giving incorrect results previously)
- Also fixed bugs manifesting under heavy load:
  - Fix monitor possibly applying incorrect PG history on retries
  - Fix monitor incorrectly changing PG count when last_clean_pgs contains less PGs than the new number
  - Allow writes to wait for free space again, but now correctly (previously dropped in 0.8.2)
  - Fix a rare segfault in client (handle client stop during incoming stream handling in 1 more place)
  - Make monitor correctly handle etcd connection errors - it could die instead of connecting to another etcd
  - Fix OSD rarely being unable to report PG states after a PG was taken over by another OSD
- Fixed return code for incomplete EC objects (now EIO) and made cluster client retry this error
- Made other small changes for tests: timeouts, nice/ionice for etcd, waiting conditions, NBD device checks and so on
2023-05-14 01:25:09 +03:00
Vitaliy Filippov 1c9a188600 Add tests to CI 2023-05-14 00:06:09 +03:00
Vitaliy Filippov de3e609166 Add a FIXME about QEMU driver thread safety 2023-05-14 00:06:09 +03:00
Vitaliy Filippov 11481170f5 Add a FIXME about ENOSPC 2023-05-13 23:59:44 +03:00
Vitaliy Filippov e69d459d43 Allow rebalance to start in test_interrupted_rebalance, raise etcd start timeout 2023-05-13 15:16:28 +03:00
Vitaliy Filippov da82754baa Wait for conditions in test_move_reappear instead of waiting a fixed amount of time 2023-05-12 23:18:07 +03:00
Vitaliy Filippov d356aca030 Add missing $NO_SAME OSD argument to test_splitbrain 2023-05-12 23:18:07 +03:00
Vitaliy Filippov 04a273d213 Raise NBD timeout in tests 2023-05-12 23:18:07 +03:00
Vitaliy Filippov 6442010f93 Skip offline PGs during state reporting when the state is already deleted or taken over by another OSD
This fixes OSDs being unable to report PG states in rare conditions
2023-05-12 23:17:45 +03:00
Vitaliy Filippov 6f4dc16c59 Handle etcd connection errors correctly in mon (unhandled error events) 2023-05-11 11:02:44 +03:00
Vitaliy Filippov ce4a8067b5 Handle client stop during incoming stream handling in 1 more place 2023-05-11 01:53:41 +03:00
Vitaliy Filippov e431ecb715 Make tests more stable in CI 2023-05-11 01:53:41 +03:00
Vitaliy Filippov 8cac795445 Return EIO instead of EINVAL for incomplete EC objects 2023-05-11 01:15:23 +03:00
Vitaliy Filippov a409598b16 Wait for free space again, but count on big_write flushes instead of just flusher activity 2023-05-10 01:51:02 +03:00
Vitaliy Filippov f4c6765522 Ignore ENOENT in epoll_ctl 2023-05-08 20:39:20 +03:00
Vitaliy Filippov ad2916068a Fix test_add_osd rebalance timeout check 2023-05-08 20:39:20 +03:00
Vitaliy Filippov 321cb435a6 Fix monitor incorrectly changing PG count when last_clean_pgs contains less PGs than the new number 2023-05-08 20:39:20 +03:00
Vitaliy Filippov cfcf4f4355 Support checking /dev/nbdX nodes in Docker 2023-05-08 20:39:20 +03:00
Vitaliy Filippov e0fb17bfee Make etcd more stable in tests (add ionice and raise timeout) 2023-05-08 20:36:00 +03:00
Vitaliy Filippov 5b9031fecc Fix monitor possibly applying incorrect PG history under heavy load
Monitor could deceive itself by immediately saving PG configuration changes
which weren't applied to etcd yet in memory, and apply incorrect PG history
changes next time if the first update fails.

This usually only happened under heavy load and was caught in CI. :-)
2023-05-07 23:23:00 +03:00
Vitaliy Filippov 5da1d8e1b5 Fix EC just-bitmap reads (len=0) (fixes SCHEME=ec test_snapshot.sh) 2023-05-07 14:00:08 +03:00
Vitaliy Filippov 44f86f1999 Add a basic EC 2+2 recovery test (not really required, but let it be there) 2023-05-07 11:26:27 +03:00
Vitaliy Filippov 2d9a80c6f6 Implement missing bitmap recovery with ISA-L \(°□°)/ 2023-05-07 11:25:51 +03:00
Vitaliy Filippov 5e295e346e Do not make vitastor-mon part of vitastor.target 2023-04-29 00:17:47 +03:00
Vitaliy Filippov d9c0898b7c Notes about config and vitastor-disk cache status 2023-04-29 00:08:24 +03:00
Vitaliy Filippov 04cfb48361 Add a note about PVE 7.4 2023-04-28 11:37:11 +03:00
Vitaliy Filippov ab615849d6 Release 0.8.8
- Fix vitastor-cli rm/rm-data broken in 0.8.6 (missing messenger initialization)
- Prepare OSD read handler for upcoming version with scrub - allow "secondary reads" to return errors
- Fix OSDs re-peering PGs infinitely with a big number of PGs (reproduced in test_add_osd)
- Fix another variant of flusher sync-waiting stall (reproduced in test_write)
- Fix other tests in tests/ (will add them to Gitea CI soon)
- Add patches for QEMU 6.2-8.0
- Fix QEMU driver compatibility with QEMU 8.0
- Build packages for RHEL 9 clones (based on AlmaLinux 9)
2023-04-28 11:22:00 +03:00
Vitaliy Filippov 38be9a49c0 Add AlmaLinux 9 build to documentation 2023-04-28 02:00:52 +03:00
Vitaliy Filippov 7d6bf84a3e Add scripts/meson-buildoptions.sh to QEMU patches 2023-04-28 01:43:22 +03:00
Vitaliy Filippov 41a40a4123 Add QEMU spec patch for Alma/Rocky/RH 9 2023-04-28 01:32:06 +03:00
Vitaliy Filippov b94587ef0e Fix some build warnings 2023-04-28 00:44:27 +03:00
Vitaliy Filippov 2a2f4f6738 Add Almalinux 9 build 2023-04-28 00:40:50 +03:00
Vitaliy Filippov c768a9015f Fix QEMU driver compatibility with QEMU 8.0 2023-04-25 11:20:21 +03:00
Vitaliy Filippov 0d9e10cf96 Add patches for QEMU 6.2-8.0 2023-04-25 11:20:21 +03:00
Vitaliy Filippov b74ccb613c Fix another variant of flusher sync-waiting stall 2023-04-24 00:44:41 +03:00
Vitaliy Filippov 5052174918 Fix test_write_no_same (too large image) 2023-04-24 00:44:41 +03:00
Vitaliy Filippov eec9cf5575 Fix test_snapshot.sh - qemu-img requires explicit backing_fmt 2023-04-24 00:44:41 +03:00
Vitaliy Filippov a04dab0840 Initialize messenger in cluster_client listings 2023-04-24 00:44:41 +03:00
Vitaliy Filippov 160863f707 Print op pointer values in slow log 2023-04-23 17:54:00 +03:00
Vitaliy Filippov 2f16c32eb4 Fix test_minsize_1 (left_on_dead) 2023-04-23 17:54:00 +03:00
Vitaliy Filippov 2877cd0adb Allow OP_SEC_READ to return errors (do not hang the connection) 2023-04-23 17:54:00 +03:00
Vitaliy Filippov 480509f5b9 Fix pg_data_size > 1 for replicas (harmless bug) 2023-04-23 01:50:42 +03:00
Vitaliy Filippov 46462da45e Preload own PG history updates to fix PG state loop possibly applying the old metadata version 2023-04-23 01:50:30 +03:00
Vitaliy Filippov 024c8658f6 Fix missing } in quick start documentation 2023-04-12 18:26:38 +03:00
Vitaliy Filippov 7e958afeda Release 0.8.7
This release includes a bunch of important bugfixes for erasure-coded setups
with disabled immediate_commit. After these fixes, "test_heal" OSD killing test
now passes fine with EC:

- Fix cluster write stalls with "Error while doing flush on OSD xx: -16 (Device or resource busy)"
  in OSD logs possible in EC setups with disabled immediate_commit by selectively
  syncing nonsynced objects on STABILIZE/ROLLBACK (https://github.com/vitalif/vitastor/issues/51)
- Fix other EC + disabled immediate_commit problems:
  - Fix "opcode=5 retval=-2" errors happening on SYNC retries
  - Fix non-working "pagination" during PG dirty object flushing
  - Fix write operations not continued correctly after dirty object flushing
- Fix incorrect parity read-modify-write calculation when writing into a lost chunk
- Fix OSDs losing left_on_dead PG state of non-clean PGs and thus not removing junk data in the cluster
- Fix a small memory leak caused by bad indexing of EC recovery matrices
- Fix a rare use-after-free in cluster_client caused by a reenterability issue
- Fix vitastor-cli create command syntax in the CSI driver
- Allow to start OSDs without local store for tests
- Fix memory allocation error in disk_tool_meta for non-standard metadata block sizes
- Fix delete operations received before loading pool metadata crashing OSDs with "null pointer exception"
- Improve "theoretical performance" Russian documentation

New features:

- Implement online configuration update for some parameters. Documentation is coming soon :)
2023-04-11 02:11:57 +03:00
Vitaliy Filippov 2f5e769a29 Fix a small memory leak caused by bad indexing of EC recovery matrices 2023-04-11 00:30:36 +03:00
Vitaliy Filippov 28d5e53c6c Add test_heal to run_tests 2023-04-09 02:10:42 +03:00
Vitaliy Filippov d9f55f11d8 More logs (log_level 10), append to log instead of overwriting on restart in tests 2023-04-09 02:06:10 +03:00
Vitaliy Filippov 3237014608 Fix incorrect parity read-modify-write calculation when writing into a lost chunk 2023-04-09 02:06:10 +03:00
Vitaliy Filippov baaf8f6f44 Fix write operations not continued correctly after flush 2023-04-09 02:06:10 +03:00
Vitaliy Filippov 1d83fdcd17 Add debug logs to osd_flush 2023-04-09 02:06:10 +03:00
Vitaliy Filippov 0ddd787c38 Fix non-working "pagination" during PG dirty object flushing 2023-04-08 02:44:02 +03:00
Vitaliy Filippov 6eff3a60a5 Do not lose left_on_dead PG state of non-clean PGs 2023-04-08 02:44:02 +03:00
Vitaliy Filippov 888a6975ab Fix a rare use-after-free in cluster_client caused by a reenterability issue 2023-04-08 02:44:02 +03:00
Vitaliy Filippov cd1e890bd4 Fix "opcode=5 retval=-2" errors sometimes possible with EC 2023-04-08 02:44:02 +03:00
Vitaliy Filippov 0fbf4c6a08 Selectively sync nonsynced objects on STABILIZE/ROLLBACK (fix for github issue #51) 2023-04-08 02:44:02 +03:00
Vitaliy Filippov d06ed2b0e7 Implement online config update 2023-03-26 19:21:50 +03:00
Vitaliy Filippov 3bbc46543d Fix vitastor-cli create syntax 2023-03-17 11:12:58 +03:00
Vitaliy Filippov 2fb0c85618 Allow to start OSDs without local store (only for tests) 2023-03-15 01:13:59 +03:00
Vitaliy Filippov d81a6c04fc Update cmake min version so it does not complain about deprecation 2023-03-15 01:08:23 +03:00
Vitaliy Filippov 7b35801647 Fix possible bad realloc in disk_tool_meta for non-standard metadata block sizes 2023-03-15 01:08:23 +03:00
Vitaliy Filippov f3228d5c07 Fix typo (did not affect execution though) 2023-03-15 01:08:23 +03:00
Vitaliy Filippov 18366f5055 Fix read/write return type in rw_blocking 2023-03-15 01:08:14 +03:00
Vitaliy Filippov 851507c147 Add missing close() in test stubs 2023-03-15 00:23:56 +03:00
Vitaliy Filippov 9aaad28488 Fix "null pointer exception" for unhandled OSD_OP_DELETEs (when pool is not loaded yet) 2023-03-02 11:16:39 +03:00
Vitaliy Filippov dd57d086fe Add a missing part of the "theoretical performance" to the Russian version 2023-03-01 00:24:54 +03:00
Vitaliy Filippov 8810eae8fb Release 0.8.6
Important fixes:

- Fix possibly incorrect EC parity chunk updates with EC n+k, k > 1 and when
  the first parity chunk is missing

Minor fixes and improvements:

- Fix incorrect EC free space statistics in vitastor-cli df output
- Speedup vitastor-cli startup in clusters with RDMA
- Remove unused PG "peered" state (previously used to update PG epoch)
- Use sfdisk with just --json in vitastor-disk (--dump --json isn't needed)
- Allow trailing comma in sfdisk output (fixes sfdisk 2.36 compatibility)
- Slightly improve RDMA send/receive code
- Reduce RDMA memory consumption by default (rdma_max_recv/send = 16/8)
- Use vitastor-cli instead of direct etcd interaction in the CSI driver
2023-02-28 11:18:48 +03:00
Vitaliy Filippov c1365f46c9 Use vitastor-cli instead of direct etcd interaction in the CSI driver 2023-02-28 11:02:50 +03:00
Vitaliy Filippov 14d6acbcba Set default rdma_max_recv/send to 16/8, fix documentation 2023-02-28 11:00:56 +03:00
Vitaliy Filippov 1e307069bc Fix missing parity chunk calculation for EC n+k, k > 1 and first parity chunk missing 2023-02-28 02:40:19 +03:00
Vitaliy Filippov c3e80abad7 Allow to send more than 1 operation at a time 2023-02-26 02:01:04 +03:00
Vitaliy Filippov 138ffe4032 Reuse incoming RDMA buffers 2023-02-26 00:55:01 +03:00
Vitaliy Filippov 8139a34e97 Fix json11: allow trailing comma 2023-02-23 01:16:01 +03:00
Vitaliy Filippov 4ab630b44d Use just sfdisk --json, --dump is not needed 2023-02-23 00:55:47 +03:00
Vitaliy Filippov 2c8241b7db Remove PG "peered" state 2023-02-21 01:30:42 +03:00
Vitaliy Filippov 36a7dd3671 Move tests to "make test" 2023-02-21 01:30:42 +03:00
Vitaliy Filippov 936122bbcf Initialize msgr lazily in client to speedup vitastor-cli with RDMA enabled 2023-02-19 18:59:07 +03:00
Vitaliy Filippov 1a1ba0d1e7 Add set_immediate to ringloop and use it for bs/osd ops to prevent reenterability issues 2023-02-09 17:37:26 +03:00
Vitaliy Filippov 3d09c9cec7 Remove unused wait_sqe() from ringloop 2023-02-09 17:37:26 +03:00
Vitaliy Filippov 3d08a1ad6c Fix cluster_client test after last reenterability fixes 2023-02-05 01:47:32 +03:00
Vitaliy Filippov 499881d81c Fix typo 2023-01-27 01:52:02 +03:00
Vitaliy Filippov aba93b951b Fix incorrect EC free space statistics in vitastor-cli df output 2023-01-26 02:04:29 +03:00
Vitaliy Filippov d125fb1f30 Release 0.8.5
- Fix a possible "double free" bug in the client library happening on OSD restart
- Fix a possible write hang on PG history update when only epoch is changed
- Fix incorrect systemd target "local.target" in mon/make-etcd
- Allow "content" option in PVE storage plugin to allow to enable containers
- Build client library without tcmalloc which fixes "attempt to free invalid pointer"
  errors when, for example, trying to run QEMU with both Vitastor and Ceph RBD disks
2023-01-25 01:43:49 +03:00
Vitaliy Filippov 9d3fd72298 Require liburing < 2 in rpm specs 2023-01-25 01:43:49 +03:00
Vitaliy Filippov 8b552a01f9 Do not retry successful operation parts in client (could lead to "double free" bugs) 2023-01-25 01:30:36 +03:00
Vitaliy Filippov 0385b2f9e8 Fix write hangs on PG epoch update - always set pg.history_changed to true 2023-01-25 01:30:15 +03:00
Vitaliy Filippov 749c837045 Replace non-existing local.target with multi-user.target 2023-01-25 01:29:31 +03:00
Vitaliy Filippov 98001d845b Remove version from vitastor-release.rpm links 2023-01-23 14:03:33 +03:00
Vitaliy Filippov c96bcae74b Allow "content" option in PVE storage plugin to allow to enable containers 2023-01-16 18:14:45 +03:00
Vitaliy Filippov 9f4e34a8cc Build client library without tcmalloc
Fixes "[src/tcmalloc.cc:332] Attempt to free invalid pointer ..." when trying
to run QEMU with both Vitastor and Ceph RBD disks and other possible allocator
collisions.
2023-01-15 00:01:11 +03:00
Vitaliy Filippov 81fc8bb94c Release 0.8.4
New features:
- Implement QCOW2 image/snapshot export via qemu-img (bdrv_co_block_status in the driver)
- Remove OSDs from PG history during `vitastor-cli rm-osd` to prevent `left_on_dead` PG states after deletion
- Add a new recovery_pg_switch setting to mix all PGs during recovery, to almost
  fully reduce the probability of ENOSPC during rebalance
- Introduce partial ENOSPC ("OSD is full") handling - now ENOSPC doesn't turn
  into cascades of crashes
- Add migration support to Proxmox VE Vitastor driver
- Track last_clean_pgs on a per-pool basis thus reducing data movement in a cluster
  with pools remaining unclean/degraded for a long time

Bug fixes:
- Fix a bug where monitor could generate degraded PGs if one of the hosts had no OSDs
- Fix a bug where monitor could skip PG redistribution with a lot of OSDs in cluster
- Report PG history synchronously on the first write, which improves PG consistency
  and availability at the same time, because history now gets reported correctly
  and doesn't get reported without the need for it
- Fix possible write and recovery stalls which could happen in a cluster with both EC and replicated pools
- Make OSD and monitors sanitize & deduplicate PG history items in etcd
- Fix non-working OSD peer config safety check
- Fix a rare journal flush stall where flushing wasn't activated with full journal, but with empty flush queue
- Fix builds without ISA-L (jerasure-only) crashing with EC N+K, K>=2 due to the lack of 16-byte buffer alignment
- Fix a possible crash for EC N+K, K>=2 when calculating a parity chunk with previous parity chunk missing
- Fix a bug where vitastor-disk purge with suppressed warnings didn't work
2023-01-13 23:59:54 +03:00
Vitaliy Filippov bc465c16de Fix arithmetic on void* for clang 2023-01-13 23:58:42 +03:00
Vitaliy Filippov 8763e9211c Fix qemu driver compilation warning/error 2023-01-13 23:44:39 +03:00
Vitaliy Filippov 9e1a80bd17 Replace apt-key with trusted.gpg.d 2023-01-13 19:51:47 +03:00
Vitaliy Filippov 3e280f2f08 Mark vitastor as shared storage in PVE driver 2023-01-13 01:36:30 +03:00
Vitaliy Filippov fe87b4076b Fix backwards compatibility in cluster_client 2023-01-12 02:37:31 +03:00
Vitaliy Filippov a38957c1a7 Skip empty hosts in lp-optimizer 2023-01-09 16:26:16 +03:00
Vitaliy Filippov 137309cf29 Implement bdrv_co_block_status for snapshot export support 2023-01-07 17:06:58 +03:00
Vitaliy Filippov 373f9d0387 Try to re-peer PGs on history change 2023-01-06 12:46:44 +03:00
Vitaliy Filippov c4516ea971 Also remove deleted OSD from PG configuration and last_clean_pgs 2023-01-06 12:46:44 +03:00
Vitaliy Filippov 91065c80fc Try to prevent left_on_dead when deleting OSDs by removing them from PG history 2023-01-06 12:46:43 +03:00
Vitaliy Filippov 0f6b946add Time changes with every stat change, do not schedule checks based on it 2023-01-05 13:54:16 +03:00
Vitaliy Filippov 465cbf0b2f Do not re-schedule recheck indefinitely, run it after mon_change_timeout in any case 2023-01-05 13:48:06 +03:00
Vitaliy Filippov 41add50e4e Track last_clean_pgs on a per-pool basis 2023-01-03 02:20:50 +03:00
Vitaliy Filippov 02e7be7dc9 Prevent reenterability side effects during PG history operation resume 2023-01-03 02:20:50 +03:00
Vitaliy Filippov 73940adf07 Prioritize EC (non-instantly-stable) operations under journal pressure
This reduces the probability of hitting OSD stalls with EC due to "deadlocks"
where two parallel write operations wait for each other to complete
2023-01-03 00:05:45 +03:00
Vitaliy Filippov e950c024d3 Do not sync peer OSDs before listing
Sync before listing was added to wait for all PG writes possibly left in queue
from the previous master to finish before listing it

But in fact it may block the cluster when EC is used and some unstable writes
are left in the queue - they block journal flushing, rollback/stabilize is
required to unblock them, but rollback/stabilize may only happen after PG is
peered. But peering needs listings, listings are requested only after sync, and
sync itself waits for currently blocked writes waiting in the queue
2023-01-03 00:05:45 +03:00
Vitaliy Filippov 71d6d9f868 Fix possible crash on ENOSPC during operation cancel in blockstore 2023-01-03 00:05:45 +03:00
Vitaliy Filippov a4dfa519af Report PG history synchronously during write
This has 2 effects:
1) OSD sets aren't added into PG history until actual write attempts anymore
   which removes unneeded extra osd_sets in PG history
2) New OSD sets are reported synchronously and can't be lost on PG restarts
   happening at the same time with reconfiguration
2023-01-01 23:41:05 +03:00
Vitaliy Filippov 37a6aff2fa Write OSD numbers always as numbers in mon 2023-01-01 23:17:42 +03:00
Vitaliy Filippov 67019f5b02 Make OSD sort & sanitize PG history items 2023-01-01 23:17:42 +03:00
Vitaliy Filippov 0593e5c21c Fix OSD peer config safety check 2022-12-31 02:24:42 +03:00
Vitaliy Filippov 998e24adf8 Add a new recovery_pg_switch setting to mix all PGs during recovery 2022-12-30 02:03:33 +03:00
Vitaliy Filippov d7bd36dc32 Fix another rare journal flush stall 2022-12-30 02:03:33 +03:00
Vitaliy Filippov cf5c562800 Log all object locations when peering PGs 2022-12-30 02:03:33 +03:00
Vitaliy Filippov 629200b0cc Return ENOSPC as the primary OSD 2022-12-30 02:03:33 +03:00
Vitaliy Filippov 3589ccec22 Do not disconnect peer on ENOSPC during write 2022-12-30 01:54:25 +03:00
Vitaliy Filippov 8d55a1e780 Build osd_rmw_test both with and without ISA-L 2022-12-29 19:13:57 +03:00
Vitaliy Filippov 65f6b3a4eb Fix jerasure crashing on bitmap calculation/restoration due to the lack of 16-byte alignment 2022-12-29 19:13:57 +03:00
Vitaliy Filippov fd216eac77 Add a test for missing parity chunk calculation 2022-12-29 19:13:57 +03:00
Vitaliy Filippov 61fca7c426 Fix crash when calculating a parity chunk with previous parity chunk missing (test coming shortly) 2022-12-29 19:13:57 +03:00
Vitaliy Filippov 1c29ed80b9 Fix quote in docs :) 2022-12-28 18:08:53 +03:00
Vitaliy Filippov 68f3fb795e Suppress warnings in vitastor-disk purge correctly 2022-12-27 11:09:19 +03:00
Vitaliy Filippov fa90f287da Release 0.8.3
- Implement a new "vitastor-disk purge" command to remove OSDs with safety checks
- Implement a new "vitastor-cli rm-osd" command to only remove OSD metadata from etcd
- Fix a bug where the monitor could ignore OSD removal and other /osd/stats key changes
- Fix a bug where garbage could be returned when reading objects being written at the same time
- Fix a rare write stall where journal space could be not reclaimed where there
  were no new operations in the flush queue
- Fix a rare peering stall caused by a previous long listing operations queues limiting attempt
- Fix total object count statistic in OSD on object creation
- Add missing offset&len into vitastor-disk dump-journal for big_writes, fix JSON format
- Make vitastor-cli print help on missing command
- Make vitastor-cli translate all '-' to '_' in CLI options
2022-12-27 02:40:55 +03:00
Vitaliy Filippov 795020674d Loop journal flusher when the queue is empty but there is a trim request 2022-12-27 02:28:20 +03:00
Vitaliy Filippov 8e12285629 Fix vitastor-disk purge (now it works) 2022-12-27 02:28:20 +03:00
Vitaliy Filippov b9b50ab4cc Implement vitastor-disk purge command 2022-12-26 02:48:48 +03:00
Vitaliy Filippov 0d8625f92d Make vitastor-cli print help on missing command 2022-12-26 02:48:48 +03:00
Vitaliy Filippov 2f3c2c5140 Implement safety check for OSD removal, translate all '-' to '_' in cli options
'-' to '_' translation fixes a bug with create --image_meta
2022-12-26 02:48:48 +03:00
Vitaliy Filippov 4ebdd02b0f Remove LIST op limiter
It doesn't prevent OSD slow ops but may itself lead to stalls :)
2022-12-26 02:48:48 +03:00
Vitaliy Filippov bf6fdc4141 Check add/rm osd with 2048 PGs 2022-12-26 02:48:48 +03:00
Vitaliy Filippov c2244331e6 Add vitastor-cli rm-osd command 2022-12-26 02:48:48 +03:00
Vitaliy Filippov 3de57e87b1 Recheck OSD tree in monitor on /osd/stats changes 2022-12-26 02:48:48 +03:00
Vitaliy Filippov 2d4cc688b2 Add a remove-osd test 2022-12-26 02:48:48 +03:00
Vitaliy Filippov 31bd1ec145 Fix object creation check for statistics 2022-12-21 02:51:11 +03:00
Vitaliy Filippov c08d1f2dfe Add missing offset&len into big_writes journal dump, fix commas again 2022-12-21 02:51:11 +03:00
Vitaliy Filippov 1d80bcc8d0 Fix blockstore returning garbage for unstable reads if there is an in-flight version
"In-flight" versions are added into dirty_db when writes are enqueued. And they
weren't ignored by subsequent reads even though they didn't have data location yet.
This bug was leading to test_heal.sh not passing sometimes with replicated setups.
2022-12-21 02:48:24 +03:00
Vitaliy Filippov 5ef8bed75f Release 0.8.2
- Fix QEMU driver compatibility with QEMU 7.0 and < 2.9
- Add patches for pve-qemu-kvm 7.1 (PVE 7.3) and pve-qemu-kvm 6.2 (PVE 7.2)
- Fix Proxmox driver location in the pve-storage-vitastor package
- Disable HDD autodetection in non-hybrid mode
- Explicitly warn about a buggy kernels on -EAGAIN in io_uring
- Final fix for the lack of zeroing out of old metadata entries
  (do not crash with "big_write journal_entry was allocated over another object"
  in some cases after an unclean OSD shutdown)
- Wait for data writes before fsyncing data if data fsync is enabled
- Never try to wait for free space inside blockstore thus stalling OSDs
- Fix a rare crash in osd_peering due to callback ordering
- Fix a rare duplication of ping & op message IDs
- Fix a rare use-after-free during pings
- Add --force to vitastor-disk read-sb
- Make vitastor-disk dump metadata object IDs in hex, add forgotten commas
- Fix vitastor-disk SCSI disk cache check
2022-12-17 17:54:13 +03:00
Vitaliy Filippov 8669998e5e Fix discard_list_subop() for local ops 2022-12-17 17:54:13 +03:00
Vitaliy Filippov b457327e77 Oops. Fix metadata read after fixes :-) 2022-12-17 17:31:57 +03:00
Vitaliy Filippov f7fa9d5e34 Fix SCSI device cache type check 2022-12-17 17:31:57 +03:00
Vitaliy Filippov 49b88b01f9 Fix clang build 2022-12-17 16:25:26 +03:00
Vitaliy Filippov 71688bcb59 Disable HDD autodetection in non-hybrid mode 2022-12-17 16:12:15 +03:00
Vitaliy Filippov 552e207d2b Explicitly print errors about -EAGAIN in io_uring 2022-12-17 15:49:49 +03:00
Vitaliy Filippov 5464821fa5 Final fix for the lack of zeroing out of old metadata entries
If a crash occurs during flushing a redirect-write it may happen so that
the disk contains both old and new metadata entries. This is OK, but prior
to 0.8.0 after this situation OSDs started without problem, but then they
crashed after some more overwrites with a "tried to overwrite non-zero
metadata entry" error. 0.8.0 introduced a change that was intended to fix
this situation, but rather than fixing it it prevented OSDs from starting,
now because of a "big_write journal_entry was allocated over another object"
error... :-)

This change finally fixes the original issue.

Followup to 54ef2c389f
2022-12-17 14:50:31 +03:00
Vitaliy Filippov 6917a32ca8 Add --force to vitastor-disk read-sb 2022-12-17 02:47:15 +03:00
Vitaliy Filippov f8722a8bd5 Dump meta in hex 2022-12-17 01:50:38 +03:00
Vitaliy Filippov 9c2f69c9fa Add forgotten commas to vitastor-disk dump-journal 2022-12-17 01:22:58 +03:00
Vitaliy Filippov 1a93e3f33a Wait for data writes before fsyncing data if data fsync is enabled 2022-12-16 20:46:55 +03:00
Vitaliy Filippov 3f35744052 Fix compatibility with QEMU aio_set_fd_handler signatures in 7.0 and < 2.9 2022-12-15 19:17:17 +03:00
Vitaliy Filippov 66f14ac019 Update notes about Proxmox 7.1-7.3 2022-12-15 18:57:28 +03:00
Vitaliy Filippov 1364009931 Add patches for pve-qemu-kvm 7.1 (PVE 7.3) and pve-qemu-kvm 6.2 (PVE 7.2) 2022-12-14 19:01:36 +03:00
Vitaliy Filippov d7e30b8353 Fix pve-storage-vitastor filename 2022-12-14 16:41:35 +03:00
Vitaliy Filippov cb437913d3 Never try to wait for free space inside blockstore 2022-12-12 00:27:05 +03:00
Vitaliy Filippov 472bce58ab Fix rare crash in osd_peering due to callback ordering 2022-12-12 00:27:05 +03:00
Vitaliy Filippov 7a71e7ef01 Fix possible duplication of ping & op message IDs 2022-12-04 00:16:47 +03:00
Vitaliy Filippov c71e5e7bbd Fix possible use-after-free during pings 2022-12-04 00:16:47 +03:00
Vitaliy Filippov 8fdf30b21f Release 0.8.1
- Remove an additional data copy operation when flushing journal (should
  slightly increase write performance)
- Fix a bug where new writes in the inmemory_journal=false mode could overwrite
  the data currently read by a parallel read operation
- Fix degraded parity writes for EC N+K when K>1 where the bug could also lead
  to an "assertion failed" error
- Fix missing journal space check for "big" writes which could lead to
  "prefill_single_journal_entry(): assertion failed..." error in OSD
- Fix possible "assertion failed: next->prev_wait >= 0" in client in rare cases
- Fix missing "len" field in vitastor-disk write-journal big_writes
- Fix possible crash of a full OSD (ENOSPC)
- Fix CSI build scripts to include newest packages every time
- Fix CSI endpoint in the liveness probe manifest
2022-11-20 11:44:09 +03:00
Vitaliy Filippov 238037ae31 Make journal trimmer wait until reads are completed when inmemory_journal is false
Without this new writes may in theory overwrite journal data being read at that time
2022-11-20 01:49:21 +03:00
Vitaliy Filippov 09a8864686 Fix degraded parity writes for EC N+K when K>1
Fixes possible `calc_rmw_parity_ec(): Assertion `bufs[i][curbuf[i]].buf' failed` error
2022-11-20 00:50:13 +03:00
Vitaliy Filippov 6e6f6ecbb0 Add missing journal space check for big_writes
Fixes possible `prefill_single_journal_entry(): Assertion `!journal.sector_info[journal.cur_sector].flush_count' failed` error
2022-11-20 00:50:13 +03:00
Vitaliy Filippov 9491f81419 Add missing documentation for OSD tags 2022-11-20 00:50:13 +03:00
Vitaliy Filippov 44c2b30167 Take newest packages every time when rebuilding CSI 2022-11-20 00:50:13 +03:00
Vitaliy Filippov bf8a0581cd Fix possible "assertion failed: next->prev_wait >= 0" in client 2022-11-20 00:50:13 +03:00
Vitaliy Filippov 5953942042 Add crc32c test utility 2022-11-20 00:50:13 +03:00
Vitaliy Filippov a276a1f737 Do not copy journal data additional time when flushing 2022-11-20 00:50:13 +03:00
Vitaliy Filippov cc24e5796e Add a FIXME 2022-11-20 00:50:09 +03:00
Vitaliy Filippov 6e26732e6a Fix skipped "len" field in vitastor-disk write-journal big_writes 2022-11-12 12:01:40 +03:00
Vitaliy Filippov b4edc79449 Fix possible segfault on ENOSPC 2022-11-12 11:59:43 +03:00
Vitaliy Filippov 5f26887d32 Fix csi endpoint in liveness probe 2022-11-10 18:37:37 +03:00
Vitaliy Filippov 11ec9ad874 Release 0.8.0
- Implement automatic OSD activation via udev and simple on-disk superblock storage
- Add a new `vitastor-disk` tool and merge all disk-related functionality there.
  Now it can prepare new OSD disks, upgrade plain old systemd units to the new scheme,
  resize OSD data area, manage OSD services by disk paths, manage superblocks,
  automatically check and disable disk cache, dump and write back journal and metadata.
- Add a documentation section about `vitastor-disk` (read it if you want details!)
- Install systemd services during package installation instead of the older method
  of manually creating them via separate shell scripts
- Add a new `make-etcd` script that reuses /etc/vitastor/vitastor.conf to configure etcd
- Allow to configure block_size, bitmap_granularity and immediate_commit per-pool
- Fix "fatal error: tried to overwrite non-zero metadata entry" which was possible
  in some cases after unclean OSD shutdown (caused by old metadata entries not being zeroed)
2022-09-05 13:51:20 +03:00
Vitaliy Filippov 83bb6598dc Fix fsync autodetection for the single-device mode 2022-09-05 13:51:20 +03:00
Vitaliy Filippov 150f369346 Hotfixes for vitastor-disk prepare: max_other, get device size, older sfdisk 2022-09-05 12:48:27 +03:00
Vitaliy Filippov 8d9a5fde15 Fix docs (block_size vs object_size) 2022-09-04 14:47:04 +03:00
Vitaliy Filippov 9ccc607ab9 Fix parse_size 2022-09-04 14:20:56 +03:00
Vitaliy Filippov 8972878c77 Fix make-etcd for ip:port 2022-09-04 14:11:59 +03:00
Vitaliy Filippov 2a1da88253 Create /etc/vitastor during package installation 2022-09-03 23:31:55 +03:00
Vitaliy Filippov 2f13f347b0 Fix space stats in mon 2022-09-03 11:16:33 +03:00
Vitaliy Filippov 9453db0e99 Add a newer make-etcd.js 2022-09-03 02:04:21 +03:00
Vitaliy Filippov a828a1233d Remove old make-osd scripts 2022-09-03 02:04:21 +03:00
Vitaliy Filippov 9481456dfe Automatically check whether to disable cache during prepare 2022-09-03 02:04:21 +03:00
Vitaliy Filippov bd11db5d0a Add vitastor-mon.service, vitastor.target, create user and log directory during package installation 2022-09-03 00:09:22 +03:00
Vitaliy Filippov 68ebe5993a Fix partition reuse 2022-09-02 23:32:25 +03:00
Vitaliy Filippov eecbfb66ce Remove the old make-osd.sh script from packages 2022-09-02 20:35:15 +03:00
Vitaliy Filippov a537db8909 Add documentation for the new "vitastor-disk" tool 2022-08-22 00:31:30 +03:00
Vitaliy Filippov 54ef2c389f Followup to the "tried to overwrite" fix: also handle it in case of inmemory_meta == false 2022-08-21 01:28:29 +03:00
Vitaliy Filippov 153c73574a Refactor blockstore_init_meta into slightly more obvious code 2022-08-21 01:21:13 +03:00
Vitaliy Filippov d83580bd68 Fix "tried to overwrite non-zero metadata entry" when during a previous metadata
flush writing new entry is completed, but zeroing out an old one isn't
2022-08-21 00:31:18 +03:00
Vitaliy Filippov 29b40aba93 Add write-meta command (for debug) 2022-08-20 23:56:57 +03:00
Vitaliy Filippov a52f2b0e8f Add write-journal command (for debug) 2022-08-20 14:05:53 +03:00
Vitaliy Filippov 1407db9c08 Fix vitastor-disk prepare bugs 2022-08-19 02:22:54 +03:00
Vitaliy Filippov c0d5e83fb8 Run partprobe when partitions do not appear 2022-08-18 02:05:16 +03:00
Vitaliy Filippov 40d8d65188 Rewrite upgrade-simple to C++ 2022-08-18 01:31:31 +03:00
Vitaliy Filippov a16263e88c Fix bugs in the upgrade script and in the udev startup script 2022-08-17 10:28:34 +03:00
Vitaliy Filippov e62bab1b39 Add systemd unit for udev deployments 2022-08-15 00:23:26 +03:00
Vitaliy Filippov cb4e3a118d Fix warning 2022-08-15 00:18:21 +03:00
Vitaliy Filippov b1e39b5dea Split disk_tool.cpp into separate files 2022-08-14 02:37:01 +03:00
Vitaliy Filippov 1170319431 Finish vitastor-disk prepare in theory 2022-08-14 02:13:24 +03:00
Vitaliy Filippov 2e0a2221eb vitastor-disk prepare: WIP second form command of the command 2022-08-12 01:58:28 +03:00
Vitaliy Filippov 5a10d135f3 Allow to configure block_size, bitmap_granularity and immediate_commit per-pool 2022-08-11 01:56:33 +03:00
Vitaliy Filippov 4c9aaa8a86 vitastor-disk prepare: implement first form of the command 2022-08-09 01:29:29 +03:00
Vitaliy Filippov ae99ee6266 Rename base64.{cpp.h} to str_util 2022-07-31 01:12:37 +03:00
Vitaliy Filippov 5af75f7d78 Implement vitastor-cli and vitastor-disk --help <command> 2022-07-31 01:10:05 +03:00
Vitaliy Filippov 7dc6f10ea1 Add read-sb command 2022-07-28 00:14:23 +03:00
Vitaliy Filippov 6fde9950d6 Implement upgrade tool from "simple" units to superblock+udev deployments 2022-07-27 02:33:43 +03:00
Vitaliy Filippov 76dd0fdcea Implement pre-exec command with on-start OSD checks 2022-07-24 15:09:45 +03:00
Vitaliy Filippov 5acc19bbd5 Implement systemctl start/stop and other commands 2022-07-23 02:18:40 +03:00
Vitaliy Filippov d5ca4e1f90 Add exec-osd command 2022-07-22 02:17:24 +03:00
Vitaliy Filippov 67e04f789f Add write-sb (superblock) command 2022-07-19 01:14:31 +03:00
Vitaliy Filippov 837407a84c Add udev import command 2022-07-19 01:14:31 +03:00
Vitaliy Filippov 1fe5908899 WIP OSD activation from superblock 2022-07-17 02:14:50 +03:00
Vitaliy Filippov dcc6d546be Move simple-offsets into vitastor-disk, too 2022-07-15 02:19:35 +03:00
Vitaliy Filippov 85fa389557 Add a test for disk-tool resize 2022-07-15 01:38:30 +03:00
Vitaliy Filippov dfa433c63b Add JSON format to dump-journal 2022-07-15 01:38:30 +03:00
Vitaliy Filippov cf487c95aa Fix resizer 2022-07-15 01:38:30 +03:00
Vitaliy Filippov b10656ca09 Parse new disk params in disk_tool resizer 2022-07-15 01:38:30 +03:00
Vitaliy Filippov ea632367e9 Do not alter dsk.meta_offset/len to skip superblock 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 4d777c6729 Set journal/meta devices to data device explicitly instead of "" 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 0c404c5074 Use blockstore_disk in disk_tool 2022-07-15 01:38:30 +03:00
Vitaliy Filippov dfd80626bd Extract disk opening functions to separate module 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 30907852c2 Use simple std::map for the config 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 078ed5b116 WIP Data area resize tool 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 73a363bf92 Rename some variables and constants 2022-07-15 01:38:30 +03:00
Vitaliy Filippov b0e86ca643 Merge dump-journal and dump-meta into the new "vitastor-disk" tool 2022-07-15 01:38:30 +03:00
Vitaliy Filippov 8800afb649 Fix void* arithmetic again 2022-07-15 01:38:30 +03:00
Vitaliy Filippov c10c90f620 Swap cli.en.md and cli.ru.md contents O_o 2022-07-15 01:38:30 +03:00
Vitaliy Filippov e20cdd13b6 Fix simple-offsets return value 2022-07-15 01:38:30 +03:00
Vitaliy Filippov d29b5d2d04 Add Russian translation of VNPL-1.1 2022-06-24 01:34:25 +03:00
Vitaliy Filippov 65b0e8e940 Fix typo in VNPL-1.1 2022-06-24 01:34:25 +03:00
Vitaliy Filippov bce357e2a5 Do not read all metadata into memory when dumping 2022-06-13 01:26:30 +03:00
Vitaliy Filippov 0876ca09cd Fix dumper includes and print format 2022-06-11 00:30:44 +03:00
Vitaliy Filippov dac12d8a4c Implement metadata dump tool 2022-06-10 18:50:09 +03:00
Vitaliy Filippov 1eec4407ab Fix inode creation when /index/maxid is out of sync 2022-06-06 16:35:51 +03:00
huy 3b7c6dcac2 Fix volume creation from snapshots in Cinder driver 2022-06-06 15:46:13 +03:00
Vitaliy Filippov 342517d126 Fix typo 2022-06-05 00:45:02 +03:00
Vitaliy Filippov 675bc12a13 Add extern "C" for systems like Gentoo which miss it in jerasure includes 2022-06-05 00:33:38 +03:00
Vitaliy Filippov 101592bbff Release 0.7.1
- Add ISA-L erasure code implementation, now used automatically instead of jerasure when available
- Fix listings sending too many parallel requests to OSDs
- Fix rm-data crashing with --wait-list
- Remove empty inodes from statistics and `ls` output, after <inode_vanish_time> seconds after deletion
- Make monitor delete pool statistics when the pool is deleted and thus remove them from `df` output
- Log multiple etcd addresses in OSD logs correctly
- Fix true/false parsing in json configs like no_recovery/no_rebalance
- Show no_recovery, no_rebalance, readonly flags in status
2022-06-05 00:07:24 +03:00
Vitaliy Filippov be4087d9d2 Add a FIXME to test_interrupted_rebalance 2022-06-05 00:06:56 +03:00
Vitaliy Filippov 404e43dd2d Note that ISA-L does not need to be enabled separately 2022-06-04 22:58:02 +03:00
Vitaliy Filippov 87613ed590 Add ISA-L into RPM specs 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 2a2e914ef9 Show no_recovery, no_rebalance and readonly flags in status 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 0cdc9292c8 Fix true/false parsing in json configs like no_recovery/no_rebalance 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 3e1b03bb5c Show all etcd addresses in the "reporting to..." message 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 36e851505a Make monitor delete pool statistics when the pool is deleted 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 1efbbb0c36 Make deleted inodes vanish from statistics after 60 seconds 2022-06-04 13:27:06 +03:00
Vitaliy Filippov 088dd15449 Exclude empty inodes from stats 2022-06-04 00:18:17 +03:00
Vitaliy Filippov 4a531d7b8b Fix listings sending too many parallel requests to OSDs, fix rm-data crashing with --wait-list 2022-06-03 23:36:37 +03:00
Vitaliy Filippov a0cae4c180 Rename "jerasure" to "ec" in pool configuration, function names, fix documentation and Debian build scripts
Old pool configurations with "jerasure" also remain supported as an alias for "ec"
2022-06-03 15:40:00 +03:00
Vitaliy Filippov c4eb46600d Merge run_3osds and run_7osds scripts 2022-06-03 01:56:36 +03:00
Vitaliy Filippov 21b306e25f Add ISA-L support 2022-06-02 01:47:33 +03:00
Vitaliy Filippov d8313e939a Release 0.7.0
- Add documentation! :-) in Russian and English
- Implement an NFS proxy for file-based access emulation to Vitastor
  images for non-QEMU based hypervisors like VMWare, as a better way
  than iSCSI
- Implement "primary affinity tags"
- Add a patch for libvirt 6.0
- Fix free_down_raw in cli status
- Fix a rare bug where OSDs could drop unrelated connections on errors
2022-05-29 23:39:53 +03:00
huynnp911 3e92c3f082 Add patch for libvirt 6.0 2022-05-28 23:53:41 +03:00
Vitaliy Filippov 82b9f4c52d Add a test with OSD kills 2022-05-28 00:51:14 +03:00
Vitaliy Filippov 2bdf415eb3 Fix unknown OSD numbers on error 2022-05-28 00:51:14 +03:00
Vitaliy Filippov f826831282 Describe OSD placement tree and reweights 2022-05-17 10:42:11 +03:00
Vitaliy Filippov 5d47bbe04c Add documentation 2022-05-17 01:10:49 +03:00
Vitaliy Filippov 93a9f1ef89 Fix NFS socket read hangs 2022-05-11 21:06:56 +03:00
Vitaliy Filippov 2697aae909 Fix free_down_raw in cli status 2022-05-11 18:08:45 +03:00
Vitaliy Filippov 6b69db73ac Remove getrandom() usage 2022-05-11 11:25:20 +03:00
Vitaliy Filippov d48a824846 Fix some warnings 2022-05-10 12:42:58 +03:00
Vitaliy Filippov 40985282ff Fix build under GCC 8 2022-05-10 12:26:47 +03:00
Vitaliy Filippov acf403e886 Add install target for NFS proxy 2022-05-10 10:43:17 +03:00
Vitaliy Filippov cf03b9c84d Implement "primary affinity tags" 2022-05-09 22:37:23 +03:00
Vitaliy Filippov 7c2379d458 Simplified NFS proxy based on own NFS/XDR implementation 2022-05-07 01:01:20 +03:00
Vitaliy Filippov a2189100dd Make CLI functions usable in library form
Return results and errors in a variable instead of just printing them,
separate vitastor-cli main() from cli_tool_t, move positional argument
parsing to CLI main from command implementations.
2022-05-06 02:18:32 +03:00
Vitaliy Filippov bb84379db6 Release 0.6.17
- Fix incorrect reading of extra metadata block leading to extra unknown objects in stats
- Fix CSI driver volumeMode: Block support
- Add block PVC and pod examples
- Fix build under 32 bit architectures
- Fix slow connection ramp-up caused by up_wait_retry_interval
2022-05-06 02:18:01 +03:00
Vitaliy Filippov 714dda8151 Fix slow connection ramp-up caused by up_wait_retry_interval pausing operations on first connection attempt 2022-05-06 02:12:08 +03:00
Vitaliy Filippov 834554c523 LD_PRELOAD=libasan.so.5 fio in tests fails when vitastor is built with ASan 2022-05-05 02:11:34 +03:00
Vitaliy Filippov e718116f54 Fix incorrect reading of extra metadata block 2022-04-21 02:52:21 +03:00
Vitaliy Filippov 98e3528a14 Add block PVC and pod examples 2022-04-17 15:43:37 +03:00
Vitaliy Filippov 8e88f77101 Fix CSI driver volumeMode: Block support 2022-04-17 15:39:11 +03:00
Vitaliy Filippov caa2cc2e6c Fix 32bit build error 2022-04-16 01:48:24 +03:00
Vitaliy Filippov 842ba8b831 Use (uint64_t)1 instead of 1l / 1ul 2022-04-16 01:48:14 +03:00
Vitaliy Filippov 1493823f9e Note about starting monitors 2022-04-12 15:00:28 +03:00
Vitaliy Filippov c857272f44 Comment: epoch is uint64_t 2022-04-10 12:21:37 +03:00
Vitaliy Filippov 340a4b4f27 Release 0.6.16
- Implement `vitastor-cli status` (print cluster status) command
- Add a new `make-osd-hybrid.js` script to quickly prepare a lot of hybrid (HDD+SSD) OSDs
- Implement snapshot deletion for Cinder driver (only works in a healthy cluster)
- Fix a huge :) bug causing reads to return all zeroes during rebalance. Add a test to prevent it in the future
- Disconnect NBD proxy correctly without leaving a zombie [vitastor-nbd] process in D state
- Fix a rare write hang appearing with small write throttling enabled
2022-04-09 01:16:52 +03:00
Vitaliy Filippov 5118980315 Add a script to run all tests 2022-04-09 01:14:00 +03:00
Vitaliy Filippov d71cc174e3 Implement CLI status command 2022-04-09 00:25:51 +03:00
Vitaliy Filippov 0eb929f1ba Fix change_pg_count test (statistic reporting may take some time) 2022-04-08 11:58:53 +03:00
Vitaliy Filippov 83146fa3e2 Fix the same HUGE bug for regular reads during rebalance 2022-04-08 11:50:09 +03:00
Vitaliy Filippov 15dcaf7903 Add the same "rebalance" test with regular reads 2022-04-08 11:48:31 +03:00
Vitaliy Filippov cd18ef7323 Disconnect NBD proxy correctly without leaving a zombie [vitastor-nbd] process in D state 2022-04-07 16:03:35 +03:00
Vitaliy Filippov 39531ef1a6 Fix incorrect chained reads during rebalance (the bug detected by test_rebalance_verify.sh) 2022-04-07 15:56:58 +03:00
Vitaliy Filippov d334914948 Fix the test so it actually fails indicating a bug :-) 2022-04-07 15:56:26 +03:00
Vitaliy Filippov c373425562 Fix nbd log 2022-04-07 15:55:38 +03:00
Vitaliy Filippov 3615e57879 Register standby monitors in etcd in /mon/member 2022-04-04 00:48:52 +03:00
Vitaliy Filippov 0edc6fe5a6 Add notes about the new script 2022-04-03 13:04:34 +03:00
Vitaliy Filippov 9c30df83e3 Fix a HUGE :) bug in NBD proxy
The bug could result in corrupted data on large writes
2022-04-03 10:42:06 +03:00
Vitaliy Filippov a420c77107 Add rebalance-verify test 2022-04-03 10:42:06 +03:00
Vitaliy Filippov 4100d829c7 Allow to override log file for daemonized NBD proxy 2022-04-03 02:41:04 +03:00
Vitaliy Filippov 79ebda933e Fix a write hang with throttling due to timer reenterability / triggerability 2022-03-28 01:42:06 +03:00
Vitaliy Filippov 65d08e067e Add a script for preparing hybrid (HDD+SSD) OSDs 2022-03-28 01:11:26 +03:00
Vitaliy Filippov d289753df4 Implement snapshot deletion for Cinder driver 2022-03-08 11:41:29 +03:00
Vitaliy Filippov 85298ddae2 Release 0.6.15
- Make peering much faster in medium to large clusters
- Fix a reenterability issue which could rarely lead to peering process hangs
2022-03-06 19:16:34 +03:00
Vitaliy Filippov e23296a327 Rename cli_rm -> cli_rm_data, cli_snap_rm -> cli_rm 2022-02-24 14:34:14 +03:00
Vitaliy Filippov 839ec9e6e0 Shard clean_db by PGs to speedup listings 2022-02-20 00:21:24 +03:00
Vitaliy Filippov 7cbfdff41a Replace some throws with force_stop 2022-02-20 00:21:19 +03:00
Vitaliy Filippov 951272f27f Try to process PG one after another 2022-02-19 19:25:55 +03:00
Vitaliy Filippov a3fb1d4c98 Fix reenterability around set_timer 2022-02-19 18:28:12 +03:00
Vitaliy Filippov 88402e6eb6 Move next_request to run_cb_and_clear 2022-02-19 16:59:03 +03:00
Vitaliy Filippov 390239c51b Don't terminate HTTP requests with timeouts if response is already available in the socket 2022-02-19 13:37:12 +03:00
Vitaliy Filippov b7b2adfa32 Fix http client not continuing requests in case of failure to connect 2022-02-19 13:36:26 +03:00
Vitaliy Filippov 36c276358b Attempt to fix "head-of-line blocking" by LIST operations 2022-02-18 01:31:45 +03:00
Vitaliy Filippov 117d6f0612 Release 0.6.14
- Fix IPv6 address parsing
- Fix "cannot read bytes of undefined" in the monitor on a fresh DB
- Fix possible hangs of read requests on OSD restarts without immediate_commit=all mode
- Fix OSDs skipping misplaced recovery in some cases
- Fix OSDs possibly dying with "map::at" errors when other OSDs are stopped
- Fix division by zero in ls if all pool OSDs are down
2022-02-17 14:43:44 +03:00
Vitaliy Filippov 7d79c58095 Use the larger sockaddr_storage structure 2022-02-12 11:22:56 +03:00
Vitaliy Filippov 46d2bc100f Add some tolerance to stat calculation so it does not fail on a fresh DB 2022-02-11 16:37:16 +03:00
Vitaliy Filippov 732e2804e9 Fix operation dependency counter underflow for reads without immediate_commit=all mode 2022-02-11 10:54:11 +03:00
Vitaliy Filippov abaec2008c Fix OSDs missing misplaced recovery 2022-02-11 01:00:24 +03:00
Vitaliy Filippov 8129d238a4 Different fio versions have different types for xfer_buflen, but Vitastor anyway does not support 128-bit offsets 2022-02-10 01:21:04 +03:00
Vitaliy Filippov 61ebed144a Fix OSDs possibly dying with "map::at" errors when other OSDs are stopped 2022-02-09 10:35:29 +03:00
Vitaliy Filippov 9d3ba113aa Extract bind socket code into a utility function 2022-02-06 00:39:52 +03:00
Vitaliy Filippov 9788045dc9 Fix division by zero in ls if all pool OSDs are down 2022-02-05 17:03:37 +03:00
Vitaliy Filippov d6b0d29af6 4k MEM_ALIGNMENT 2022-02-05 17:03:37 +03:00
Vitaliy Filippov 36f352f06f Release 0.6.13
- Fix client hangs possible on OSD restarts (bug affected versions from 0.5.11)
- Fix "Assertion `sqe != NULL' failed" io_uring-related crashes possible
  on some kernels (0.6.11 increased probability of this bug)
- Fix timeout=0 in NBD proxy
- Fix build under centos 7
2022-02-03 01:50:30 +03:00
Vitaliy Filippov 318cc463c2 Fix warnings 2022-02-03 01:50:30 +03:00
Vitaliy Filippov 145e5cfb86 MCL_ONFAULT is not available under centos 7 2022-02-03 01:42:19 +03:00
Vitaliy Filippov 73ae578981 Add osd_memlock option 2022-02-02 01:40:22 +03:00
Vitaliy Filippov 20ee4ed758 Update some parameter docs 2022-02-01 22:46:13 +03:00
Vitaliy Filippov 63de79d1b2 Change > to | to preserve newlines 2022-02-01 22:45:12 +03:00
Vitaliy Filippov f712967079 And one more sqe starvation fix 2022-02-01 02:50:16 +03:00
Vitaliy Filippov df0cd85352 Fix another part of the "async sqe clear" bug (followup to d9857a5340) 2022-02-01 01:14:56 +03:00
Vitaliy Filippov ebaf4d7a72 Fix compatibility with fio 3.28+ 2022-01-31 23:39:14 +03:00
Vitaliy Filippov d4bc10542c Fix compatibility with liburing >= 2.1 where it only has __pad2[2] 2022-01-31 22:49:40 +03:00
Vitaliy Filippov 140309620a Free recv_buf in nbd_proxy 2022-01-31 20:37:58 +03:00
Vitaliy Filippov 0a610ee943 Destroy the client after completing CLI command 2022-01-31 18:27:04 +03:00
Vitaliy Filippov f3ce166064 Do not print nan% in df when a pool has no available OSDs 2022-01-31 18:23:57 +03:00
Vitaliy Filippov 717d303370 Handle get_sqe failures, don't die with "will fall out of sync" in epoll_manager
Problem is that in recent kernels io_uring may return completions BEFORE
clearing the submission queue. I.e. for example its capacity is 512, there
were 512 requests, one of them completed, so when the request completion is
processed the queue "should have" 1 free slot. But sometimes it doesn't because
io_uring doesn't always clear the submission queue before sending CQE :-/
2022-01-31 02:52:20 +03:00
Vitaliy Filippov d9857a5340 Check for SQEs, not for completions
Should finally fix Assertion `sqe != NULL' failed introduced after journaling
refactor in 0.6.11...
2022-01-31 02:19:10 +03:00
Vitaliy Filippov eb5d9153e8 Fix build under centos 7 2022-01-30 20:29:44 +03:00
Vitaliy Filippov ae6d1ed1d5 Remove completed items 2022-01-30 20:20:06 +03:00
Vitaliy Filippov d123e58ea3 Fix yaml syntax - remove ` in default 2022-01-29 02:08:48 +03:00
Vitaliy Filippov d9869d8116 Add parameter documentation 2022-01-28 02:45:54 +03:00
Vitaliy Filippov 4047ca606f Add missing cancel_op(currently being read op) when stopping a client
Fixes client hangs possible after stopping & restarting an osd.
Hangs happened when a connection was closed in the middle of reading a READ
operation reply from the network. In this case the operation being read was
in read_op and the client didn't free it when closing the connection.

Test case for msgr_read.cpp:
- Partially read reply for a READ operation
- stop_client()
- Check that the READ operation returns EPIPE

The bug was actually introduced in 0.5.11.
2022-01-28 01:53:52 +03:00
Vitaliy Filippov 218e294e9c > 0, of course 2022-01-24 13:36:09 +03:00
Vitaliy Filippov c1929cabe0 Release 0.6.12
etcd connection stability, clang & elbrus support

- Fix build under CLang and Elbrus LCC compilers, making Vitastor compatible
  with Elbrus CPUs :)
- Completely fix the bug where OSDs didn't connect to peers and incorrectly marked
  PGs as incomplete
- Limit I/O depth for deletes the same way as for small writes. Makes OSD crashes
  with "Assertion failed: sqe != NULL" during image deletion go away
- Fix a very old, but rare, journaling bug (credits to https://github.com/mirrorll)
- Fix flushing of unclean journaled objects leading to OSDs sometimes hanging
  after failover in EC setups (bug was introduced in 0.6.7)
- Fix several problems that could prevent smooth operation of a Vitastor cluster
  under the condition of partial etcd failure:
  - OSDs could randomly fail due to too strict error handling
  - New clients and OSDs could be unable to start because of the lack of retries
  - CLI could fail some commands because of the lack of retries
  - Monitor could stop receiving state updates because of the lack of websocket pings
- Fix monitor being unable to rebalance PGs after a downscale of pool pg_size (3->2)
- Exit with failure when trying to nbd map or benchmark a non-existing image
- Use HTTP keep-alive for etcd connections
- Allow to configure etcd request timeouts and retries
- Allow to configure NBD timeout, max devices and partitions, and set default to
  up to 64 devices with up to 3 partitions each
2022-01-24 01:15:25 +03:00
Vitaliy Filippov cc6b24e03a Allow to configure NBD timeout, max devices and partitions
Also set default NBD devices/partitions to 64/3, Linux default is 16/16 which is way too low
2022-01-24 01:15:19 +03:00
Vitaliy Filippov 0757ba630a Do not happily NBD "map" non-existing images, do not try to benchmark them too 2022-01-23 23:03:42 +03:00
Vitaliy Filippov 2a0b881685 Respect max_write_iodepth for deletes 2022-01-23 22:05:23 +03:00
Vitaliy Filippov 9a15b843ff Do not set pg_real_size to 0 2022-01-23 20:15:04 +03:00
Vitaliy Filippov 8dc1ffb13b Try to connect with PG peers before deciding it's incomplete :)
I already attempted to fix it in 0.6.11, but it happened so that the fix was
only partial :)
2022-01-23 19:19:26 +03:00
Vitaliy Filippov ba63af49b4 Add etcd retries everywhere (they were missing in some places) 2022-01-23 17:21:48 +03:00
Vitaliy Filippov 31b9c683ee Fix flushing of unclean objects
This was preventing OSD failover when there were some unclean objects.
Bug was introduced in aa436027c8
2022-01-23 00:45:11 +03:00
Vitaliy Filippov 3abcac058f Check for double response_callback call more 2022-01-23 00:26:20 +03:00
Vitaliy Filippov e01c4db702 Add paranoic if()s to prevent accidental double free of etcd_watch_ws 2022-01-23 00:16:09 +03:00
Vitaliy Filippov a5cf06acd0 Remove etcd timeout and keepalive interval hardcode 2022-01-23 00:00:00 +03:00
Vitaliy Filippov 9c3653b1e1 Handle EINTR 2022-01-22 23:59:37 +03:00
Vitaliy Filippov 23e578b6a2 Fix common.sh 2022-01-21 01:51:25 +03:00
Vitaliy Filippov 7920414bee Fix build under older gcc (debian buster) 2022-01-20 10:34:52 +03:00
Vitaliy Filippov 098e369a3b Fix rand initialization, add etcd connection/disconnection logging 2022-01-20 00:45:49 +03:00
Vitaliy Filippov a43ef525a2 Remove two last end()s from http_client (should have been removed in the keepalive patch) 2022-01-20 00:44:18 +03:00
Vitaliy Filippov 8a6b07d8f7 Add a 2/5 etcd failure test 2022-01-20 00:43:22 +03:00
Vitaliy Filippov 2c930d55fb
Merge pull request #41 from promobit-bitblaze/1-small-fix
#1 fix deps
2022-01-18 11:19:08 +03:00
Mikhail Koshel d798e0821e #1 fix deps 2022-01-18 13:30:53 +06:00
Vitaliy Filippov e591a3e9f7 Include sys/stat.h in messenger.cpp
No idea why, but it builds without it on x86 and does not build on e2k
2022-01-17 13:43:29 +03:00
Vitaliy Filippov 77cc18420a Fix leaks detected by clang scan-build (only 1 of 4 may be important though) 2022-01-16 00:11:59 +03:00
Vitaliy Filippov 7bdd92ca4f Fix build under clang and some warnings
Build problems fixed:
- void* pointer arithmetic which is a GNU extension (works as byte*)
- "variable size object may not be initialized" which is OK under GCC
- nullptr_t related error in json11 (it lacks 'operator <' in clang)

Warnings fixed:
- empty nested struct initializer { 0 } replaced by {}
- removed several unused lambda captures
2022-01-16 00:02:54 +03:00
Vitaliy Filippov 8f64fc61e7 Ignore empty events in mon 2022-01-08 11:41:00 +03:00
Vitaliy Filippov 4a9f001d9e Make mon also ping etcd websockets regularly 2022-01-05 17:28:51 +03:00
Vitaliy Filippov 8c908316d9 Add a test with an OSD being added 2022-01-05 17:06:24 +03:00
Vitaliy Filippov 515a2e6e33 Only die when detecting a real race condition, not just a CAS failure 2022-01-05 17:05:25 +03:00
Vitaliy Filippov 68b6763ebe Add asserts for lp-optimizer tests, pass `ordered` from the monitor 2022-01-03 20:37:07 +03:00
Vitaliy Filippov 9c6168bf17 Remove fill_parsed_response 2022-01-03 20:08:26 +03:00
Vitaliy Filippov 08e467270a Fix pg_size changing from 3 to 2 2022-01-03 17:56:54 +03:00
Vitaliy Filippov 5473d5b4a2 Rework HTTP client to use keepalive, move getifaddr_list to addr_util 2022-01-03 14:52:01 +03:00
Vitaliy Filippov c3304bce27
Merge pull request #38 from mirrorll/master
journal check_available error
2021-12-31 12:45:16 +03:00
Vitaliy Filippov ec2852c598 Add minsize_1 test 2021-12-28 10:54:36 +03:00
Vitaliy Filippov b9f5c2a823 Support zero-copy send in fio_sec_osd to allow testing it
Prelimilary results:
- CPU usage drops significantly. For example, in T1Q8 128K write test against
  stub_uring_osd with 10G network and Athlon X4 860k CPU it drops from 100% to 30%
- Latency becomes slightly worse. In T1Q1 4K write test in the same environment
  latency increases from 56 to 63 us.
- Small write throughput also becomes slightly worse. In T1Q128 4K write test
  against stub iops decreases from 138k to ~110k (unstable, fluctuates 100k..120k).
  Note that this is without io_uring, of course.
2021-12-27 02:12:44 +03:00
Vitaliy Filippov e9d2f79aa7 Support reading bitmaps in fio_sec_osd 2021-12-27 02:12:44 +03:00
Vitaliy Filippov 0785bdf8b3 Release 0.6.11
- Slightly reduce journaling write amplification (requires no_same_sector_overwrites=false)
- Fix listen_backlog (it was 0) because it could more than halve OSD socket send speed
- Support IPv6 OSD addresses
- Do not try to initialize client in simple-offsets
- Fix OSDs sometimes marking PGs incomplete instead of trying to connect with peers
- Allow to configure OSD placement in node_placement
- Allow to run with 4k sector size block devices. Natural, but it was forbidden
2021-12-26 21:11:24 +03:00
Vitaliy Filippov b57e44748b Send 4 byte bitmap in stub_uring_osd 2021-12-25 11:38:13 +03:00
Vitaliy Filippov 1bbe62f29c Fix uninitialized listen_backlog which was leading to REALLY SLOW send speeds!!! 2021-12-25 11:38:13 +03:00
lihai 3061c30132 journal check_available error 2021-12-21 09:39:58 +08:00
Vitaliy Filippov 20a4406acc Support IPv6 OSD addresses 2021-12-19 10:42:17 +03:00
Vitaliy Filippov f93491bc6c Implement journal write batching and slightly refactor journal writes
Slightly reduces WA. For example, in 4K T1Q128 replicated randwrite tests
WA is reduced from ~3.6 to ~3.1, in T1Q64 from ~3.8 to ~3.4.

Only effective without no_same_sector_overwrites.
2021-12-16 00:27:17 +03:00
Vitaliy Filippov 999bed8514 Fix opening regular files as blockstore 2021-12-15 02:08:58 +03:00
Vitaliy Filippov 3f33095fd7 Do not try to initialize client in simple-offsets 2021-12-15 02:07:27 +03:00
Vitaliy Filippov dd74c5ce1b Fix OSDs marking PGs incomplete instead of trying to connect with peers 2021-12-14 01:57:51 +03:00
Vitaliy Filippov c6d104ecd6 Print object version on fatal overwrite 2021-12-14 01:57:04 +03:00
Vitaliy Filippov e544aef7d0 Fix test rw_blocking 2021-12-12 23:24:50 +03:00
Vitaliy Filippov 616c18c786 Fix stub_uring_osd 2021-12-12 23:06:11 +03:00
Vitaliy Filippov fa687d3878 Allow to configure OSD placement in node_placement 2021-12-12 01:25:45 +03:00
Vitaliy Filippov 2c7556e536 Allow to run with 4k sector size. Natural, but it was forbidden 2021-12-11 22:03:16 +00:00
Vitaliy Filippov 2020608a39 Release 0.6.10
- Implement a storage plugin for Proxmox. Now you can use Vitastor with Proxmox!
- Implement `vitastor-cli df` (pool space usage statistics) command
- Add glob pattern support for `vitastor-cli ls`
- Fix several bugs in other CLI commands (resize, create --parent, modify --readonly)
- Use 512 byte logical block size in QEMU driver by default (and thus don't require to set it in QEMU options)
2021-12-10 21:40:12 +03:00
Vitaliy Filippov 139b98d80f Exclude block/vitastor.c from patches and add script to easily re-add it 2021-12-10 21:38:36 +03:00
Vitaliy Filippov f54ff6ad5d Do not crash in simple-offsets when some options are empty, too 2021-12-10 12:27:25 +03:00
Vitaliy Filippov b376ef2ed9 Do not crash on empty matched_addrs 2021-12-10 11:40:59 +03:00
Vitaliy Filippov 5a234588b9 Do not die when invoked via `vita` symlink 2021-12-10 02:45:16 +03:00
Vitaliy Filippov b82c30328f Use vitastor-cli df to show pool stats in Proxmox 2021-12-10 02:42:31 +03:00
Vitaliy Filippov 0ee5e0a7fe Implement vitastor-cli df command 2021-12-10 02:37:02 +03:00
Vitaliy Filippov 0a1640d169 Some important fixes for our new Proxmox driver 2021-12-10 01:17:06 +03:00
Vitaliy Filippov 3482bb0860 Fix readonly/readwrite option parsing 2021-12-10 00:52:59 +03:00
Vitaliy Filippov 526995f486 Do not skip empty iops in listings 2021-12-10 00:52:59 +03:00
Vitaliy Filippov 073b505928 Package Proxmox plugin as pve-storage-vitastor 2021-12-10 00:22:45 +03:00
Vitaliy Filippov a8b21a22d0 Add patch for pve-qemu 6.1 2021-12-09 02:57:43 +03:00
Vitaliy Filippov 0b1ffba62b Add Proxmox storage driver 2021-12-09 02:26:54 +03:00
Vitaliy Filippov 8dfbd7943c Use logical block size = 512 bytes by default 2021-12-08 23:43:40 +03:00
Vitaliy Filippov 39e7f98e54 Allow to change etcd IP in tests 2021-12-08 23:00:48 +03:00
Vitaliy Filippov 3a83a32cb7 Aaand now fix create --parent :D 2021-12-08 23:00:34 +03:00
Vitaliy Filippov 20d5ed799a Add glob pattern matching for ls 2021-12-08 23:00:34 +03:00
Vitaliy Filippov b262938bca Fix naggy "Failed to get RDMA device list: Unknown error -38" 2021-12-08 02:02:30 +03:00
Vitaliy Filippov 7e54242251 Add patches for Proxmox QEMU 5.1 and 52 2021-12-05 17:45:01 +03:00
Vitaliy Filippov c3c2e68cc1 Now fix resize command :D 2021-12-05 01:38:08 +03:00
Vitaliy Filippov aa1e21dd99 Release 0.6.9
New features:
- Build Vitastor driver as part of QEMU
- Implement renaming images in CLI (vitastor-cli modify --rename)
- Add vitastor-cli alloc-osd and simple-offsets commands and use them in make-osd,
  thus removing the dependency on etcdctl
- Make monitor remove stale deleted inode statistics from etcd automatically
- Implement OSD address selection from a subnet, thus removing the need to specify
  OSD addresses in startup scripts explicitly

Bug fixes:
- Fix client failover in case of etcd shutdown or crash (make client survive etcd failures)
- Stick to the last live etcd in OSD and mon to prevent random failures when one of etcds is down
- Fix incorrect copying of data from journal to the data device which could lead to data corruption
- Prefer local etcd IPs in OSD
- Remove the total PG count restriction in optimize_change which was sometimes leading
  to inability to redistribute PGs over OSDs
- Fix error response parsing on a failed pg state report
- Fix slow linear writes with RDMA by changing default buffer settings
- Fix possible 'TypeError' in openstack nova when using Vitastor cinder driver
- Fix bugs in vitastor-cli create, ls, rm, modify commands

Patch changes:
- Add a patch for libvirt 7.6
- Add patches for QEMU 6.0 and 6.1
- Fix config file path XML location parsing in libvirt patches
- Replace _ with - in QEMU options
- Fix possible 'TypeError' in openstack nova when using Vitastor cinder driver
- Fix possible crashes of QEMU block driver in case of incorrect options
2021-12-03 10:58:54 +03:00
Vitaliy Filippov f4b57d487f Remove +deb10u1 from libvirt version 2021-12-03 10:56:44 +03:00
Vitaliy Filippov 711ecd2f8e Add a Dockerfile to build libvirt 2021-12-03 03:00:10 +03:00
Vitaliy Filippov 9fca01dc62 Add a forgotten return statement 2021-12-03 00:41:49 +03:00
Vitaliy Filippov 0bd3a94efd Use qdict_get_try_int because qdict_get_int may segfault on a missing key 2021-12-03 00:22:17 +03:00
Vitaliy Filippov 9ffdeef93b Install the built liburing version in el8 dockerfile 2021-12-03 00:04:18 +03:00
Vitaliy Filippov 589892d501 Fix rpm dockerfiles 2021-12-02 10:19:47 +03:00
Vitaliy Filippov 5fe3a40416 More fixes for QEMU 2.x :) 2021-12-02 02:25:50 +03:00
Vitaliy Filippov a453db9c8e An attempt to automatically build patched specs inside Docker is mostly broken for now 2021-12-02 01:51:48 +03:00
Vitaliy Filippov e6498a52ca Rename 4.2 el7 spec patch 2021-12-02 01:47:44 +03:00
Vitaliy Filippov 4bc41aed9d Add patches for QEMU 6.0 and for 6.0 RPM spec 2021-12-02 01:47:20 +03:00
Vitaliy Filippov 4da51f9c4c Update QEMU 3.1 patch 2021-12-02 01:29:21 +03:00
Vitaliy Filippov c6cee6f734 Update QEMU 5.0 patch 2021-12-02 01:27:00 +03:00
Vitaliy Filippov 6fc08f5581 Update CentOS 8 QEMU 4.2 spec patch 2021-12-02 01:23:43 +03:00
Vitaliy Filippov 15957b7d13 Update QEMU 4.2 patch and CentOS 7 QEMU 4.2 spec patch 2021-12-02 01:03:19 +03:00
Vitaliy Filippov 09a3987e83 Remove vitastor-qemu from RPM specs 2021-12-01 23:42:20 +03:00
Vitaliy Filippov cd6820c439 Update QEMU 5.1/5.2 patch to include internal vitastor driver 2021-12-01 02:08:02 +03:00
Vitaliy Filippov dcd8f5e76c Remove qemu shenanigans from vitastor build dockerfile 2021-12-01 02:00:14 +03:00
Vitaliy Filippov 5859f913fc Fix client failover in case of etcd shutdown or crash 2021-12-01 00:33:02 +03:00
Vitaliy Filippov cac6a1d8d1 Don't need to download fio in qemu dockerfile anymore 2021-11-30 22:24:48 +03:00
Vitaliy Filippov a0c32e7de9 Update patch for libvirt 7.6 2021-11-30 10:23:51 +03:00
Vitaliy Filippov 8b37610dd0 Rename patch to Nova 23 because it's actually closer 2021-11-30 02:05:24 +03:00
Vitaliy Filippov ae82ca3b08 Pass config path in <config file="" /> element instead of an attribute
libvirt has always had config in the element for Ceph, we don't want to break it
2021-11-30 02:02:07 +03:00
Vitaliy Filippov 92362027a8 Build vitastor driver as part of the QEMU package by default
Old behaviour can be restored with cmake var WITH_QEMU=true
2021-11-29 02:05:26 +03:00
Vitaliy Filippov c4aeeda143 Fix index removal in vitastor-cli rm 2021-11-29 02:00:05 +03:00
Vitaliy Filippov 24f0f8278a Fix modify --readwrite 2021-11-29 01:52:21 +03:00
Vitaliy Filippov 95496d0845 Implement renaming images in CLI (vitastor-cli modify --rename) 2021-11-28 22:38:57 +03:00
Vitaliy Filippov 94b1f09ef2 Create snapshots in the same pool by default 2021-11-28 21:50:42 +03:00
Vitaliy Filippov 32b1312abb Remove stale deleted inode statistics in monitor 2021-11-28 21:02:05 +03:00
Vitaliy Filippov d5c8fde5de Remove kludgy $IP and $ETCD_MON parsing from make-osd.sh, suggest to use vitastor.conf 2021-11-28 18:27:05 +03:00
Vitaliy Filippov 7a0b5212fe Exit if unable to restart watches
FIXME: It's probably not OK for the client to exit in this case
2021-11-28 01:43:31 +03:00
Vitaliy Filippov a8f5c71ae8 Use the same etcd address selection algorithm in the monitor 2021-11-28 01:19:42 +03:00
Vitaliy Filippov ce5b6253ab Make OSDs stick to the last successful etcd address
Previously OSDs were selecting a new random etcd from the cluster
on every request so they were failing randomly when part of etcds was down
2021-11-27 23:48:56 +03:00
Vitaliy Filippov 8398ad0117 Fix #36 - Fix old version data sometimes overriding new version data
Reproduction case:
- v3 = (offset 4kb, length 16kb)
- v2 = (offset 24kb, length 16kb)
- v1 = (offset 16kb, length 16kb)
- At the third step it was inserting 16..24kb instead of 20..24kb
2021-11-27 01:17:45 +03:00
Vitaliy Filippov fea451b4db Prefer local etcd in OSD 2021-11-27 00:36:53 +03:00
Vitaliy Filippov 6e12aca53b Remove the total PG count restriction in optimize_change which was leading to unfeasible problems sometimes 2021-11-26 23:05:37 +03:00
Vitaliy Filippov 8b007d531f
Merge pull request #33 from moly7x/fix-TypeError
Fixed TypeError
2021-11-25 14:47:31 +03:00
Vitaliy Filippov 7b7f20fb89
Merge pull request #34 from mirrorll/master
report pg state failed
2021-11-25 10:26:42 +03:00
Vitaliy Filippov 300d507026 Fix capture of out in alloc_osd 2021-11-25 10:20:01 +03:00
harley 6886171289
report pg state failed
after report pg state failed parse response error
2021-11-25 09:34:34 +08:00
Vitaliy Filippov 43f8ea47a0 Ok, something is not allowed somewhere in C99 2021-11-24 11:28:10 +03:00
Vitaliy Filippov 6e0e172e15 Implement OSD address selection from a specified subnet 2021-11-23 21:59:26 +03:00
Vitaliy Filippov 655a2c871d Move make-osd.sh into vitastor-client package 2021-11-21 16:33:33 +03:00
Vitaliy Filippov 879fe9b2b4 Add a patch for qemu 6.1 and replace _ with - in qemu options 2021-11-21 16:24:30 +03:00
Vitaliy Filippov 660c3f7b0d Change default RDMA settings to 128x 129K buffers
129K to leave extra space for the header

The problem with 8x 1M buffers is that the following happens with,
for example, 2 OSDs and 4M T1Q1 write:
- Server posts 8 receives
- Client posts 8 sends
- WRs are processed by the RDMA stack, but the OSD doesn't have the time
  to handle them and doesn't refill buffers
- Client posts 1 more send
- RNR retransmission happens and performance drops to zero

Overall it seems that RDMA support should be reworked to use real 'RDMA'
operations i.e. operations writing into remote memory. This has an
additional advantage of avoiding a copy at the receive side of the OSD.
2021-11-21 12:05:52 +03:00
Vitaliy Filippov f0ebfae3b8 Fix vitastor-cli alloc-osd, use vitastor-cli in make-osd.sh 2021-11-21 00:01:03 +03:00
Vitaliy Filippov eb7ad2c114 Fix empty size syntax, use C version of simple-offsets in tests 2021-11-20 23:51:26 +03:00
Tân Lê b4235b4edf
Fixed TypeError
Fix `TypeError: Argument must be bytes or unicode, got 'int'` in nova-compute.
2021-11-19 13:37:47 +07:00
Vitaliy Filippov cd21ff0b6a Rewrite simple-offsets.js in C/C++ 2021-11-19 02:39:56 +03:00
Vitaliy Filippov d3903f039c Implement alloc-osd (allocate a new OSD number) command 2021-11-19 02:39:37 +03:00
Vitaliy Filippov 66fe1a469b Additionally balance parity chunks over OSDs using round-robin when generating initial distribution 2021-11-16 21:02:39 +03:00
Vitaliy Filippov 24409bd4c4 Oops # 2. Fix vitastor-cli create broken due to json11 :D 2021-11-16 12:52:35 +03:00
Vitaliy Filippov c5029961ea Oops. Fix vitastor-cli ls 2021-11-16 12:39:41 +03:00
Vitaliy Filippov 1ca1143d4a Add fio_version and qemu_version variable example files back 2021-11-15 17:21:01 +03:00
Vitaliy Filippov 920345f7b6 Release 0.6.8
- Build separate packages for OSD, monitor, client, C header, fio and QEMU drivers
  instead of one package which included everything
2021-11-15 00:49:21 +03:00
Vitaliy Filippov 75b47a6298 Generate pkg-config file 2021-11-15 00:49:21 +03:00
Vitaliy Filippov 6e446653ae Include README 2021-11-15 00:00:02 +03:00
Vitaliy Filippov e51edf2542 Split into multiple rpm packages 2021-11-14 23:48:50 +03:00
Vitaliy Filippov ce170af91f Split into multiple Debian packages 2021-11-14 23:31:30 +03:00
Vitaliy Filippov 7eabc364bf Release 0.6.7
- Implement CLI commands for listing, viewing I/O statistics, creating,
  snapshotting, cloning, resizing and modifying images. All these operations
  are covered by 3 commands: ls, create, modify
- Implement an important fix to prior OSD set tracking for PGs. The previous
  version had an issue which could lead to data loss due to an OSD with older
  copy of the data thinking it has the newest copy
- Fix I/O statistics aggregation in the monitor
- Several minor fixes for Cinder driver
- Fix QEMU driver to be compatible with QEMU 2.x > 2.0
- Fix stalls sometimes possible in configurations without immediate_commit due
  to insufficient amount of automatic internal fsync operations
- Add `vita` alias for `vitastor-cli`
2021-11-13 23:23:55 +03:00
Vitaliy Filippov a346f84c69 Allow to show only specific images in listing 2021-11-13 23:23:55 +03:00
Vitaliy Filippov 71a0c1a7b9 Fix list sorting 2021-11-13 23:23:55 +03:00
Vitaliy Filippov 20e86c7d84 Note about vitastor-cli 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 110b39900b Rename the new "set" command to "modify" 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 697ee30a26 Add ARG REL into build Dockerfiles 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 42479b4590 Fix vitastor-nbd list, add ls alias 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 6e82044e84 Add `vita` symlink 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 2cb3e84882 Implement CLI set (resize, change readonly status) command 2021-11-13 22:39:17 +03:00
Vitaliy Filippov 32614c5bc8 Add a test for the last change ("split-brain avoidance", lol) 2021-11-13 22:39:17 +03:00
Vitaliy Filippov aa436027c8 Report pg/history from OSD on every degraded activation
Required to prevent data loss due to activation of an OSD with older data
when PG OSD set change doesn't occur. I.e. fixes the simplest case:
- Run 2 OSDs with 1 PG
- Start writing into the PG
- Stop OSD 2
- Stop OSD 1
- Start OSD 2

After this change the PG will refuse to start after the last step.
2021-11-13 22:39:17 +03:00
Vitaliy Filippov 577a563b91 Allow to disable colored output 2021-11-11 01:41:58 +03:00
Vitaliy Filippov e4efa2c08a Improve vitastor-cli ls - show I/O statistics, allow to sort & limit output 2021-11-11 01:41:58 +03:00
Vitaliy Filippov 0f3f0a9d29 Calculate average statistics in mon, remove buggy "fix_stat_overflows" 2021-11-11 00:20:57 +03:00
Vitaliy Filippov 0544a16f95
Merge pull request #30 from moly7x/moly7x-fix-No-weighed-backend-found
Fix No weighed backend found
2021-11-10 17:13:17 +03:00
Tân Lê 30d8930958
Revert spacing in comment 2021-11-10 10:47:58 +07:00
Tân Lê baf003fbd3
Revert newline in comment 2021-11-10 10:43:24 +07:00
Tân Lê ba39a38dc4
Fix No weighed backend found 2021-11-10 10:27:01 +07:00
Vitaliy Filippov d528cd77f1 Fix install_symlink 2021-11-09 16:42:29 +03:00
Vitaliy Filippov 6e6f407df3 Simplify & fix monitor stats aggregation 2021-11-09 01:41:22 +03:00
Vitaliy Filippov 4d43774cbb Use 5s etcd_report_interval by default 2021-11-09 01:27:12 +03:00
Vitaliy Filippov a1488f7217 Fix qemu_driver to build with QEMU 2.x (previously it was only correct for QEMU 2.0) 2021-11-08 23:07:31 +03:00
Vitaliy Filippov 404e07d365 Implement image/snapshot/clone creation and listing by pool 2021-11-07 01:01:07 +03:00
Vitaliy Filippov b3dcee0d43 Also print "bare" inodes with missing config if they occupy space 2021-11-06 14:56:41 +03:00
Vitaliy Filippov 609bd4eb59 Remove naggy RDMA messages when log level is zero 2021-11-06 14:36:23 +03:00
Vitaliy Filippov 8e445ddc9a Begin to implement CLI: implement listing, add help, add create stub 2021-11-06 14:32:19 +03:00
Vitaliy Filippov ffb06536ff Revoke lease in mon on SIGINT & SIGTERM, fix raw_to_usable calculation 2021-11-06 13:54:35 +03:00
Vitaliy Filippov eeecab20c2
Merge pull request #28 from moly7x/fix
Fix building QEMU 3.1
2021-11-06 11:12:17 +03:00
Tân Lê e889ac4209
Fix building QEMU 3.1 2021-11-05 13:45:51 +07:00
Vitaliy Filippov cfe8de9b84 Autosync based on number of unstable ops to prevent journal stalls 2021-10-30 14:26:48 +03:00
Vitaliy Filippov 24b9b19066 Change rm to rm-data as it was renamed 2021-10-23 10:39:20 +03:00
Vitaliy Filippov ef645ee0c2
Merge pull request #26 from moly7x/fix
FIX ERROR cinder.volume.drivers.vitastor KeyError: 'total_raw_tb'
2021-10-22 21:29:52 +03:00
Tân Lê 8a9bae5216 FIX ERROR cinder.volume.drivers.vitastor KeyError: 'total_raw_tb' 2021-10-22 11:38:50 +07:00
Vitaliy Filippov da99686a15 Correctly aggregate pool statistics for unknown pools 2021-10-21 18:58:56 +03:00
Vitaliy Filippov dcc03ee41f Add go.sum 2021-10-19 02:42:10 +03:00
Vitaliy Filippov fb2f7a0d3c Release 0.6.6
- New command-line tool: vitastor-cli
- Implement layer (snapshot/clone) merge and delete
- Remove 'bool' from the C header
- Fix a very rare flusher stall
- More diagnostics now printed for slow ops in the log
2021-10-19 02:26:37 +03:00
Vitaliy Filippov 38d85da19a Fix build for older gcc 2021-10-19 02:26:37 +03:00
Vitaliy Filippov dc3caee284 Add Dockerfile 2021-10-19 02:26:37 +03:00
Vitaliy Filippov 89dcda1fed Remove "bool" from the C header 2021-10-18 01:49:07 +03:00
Vitaliy Filippov 1526e2055e Do not crash with RDMA when receiving garbage, free RDMA buffers when connection is closed 2021-10-15 23:56:22 +03:00
Vitaliy Filippov 74cb3911db Rebase children of the "inverse" child when it is removed, change /index/image/%s keys during metadata ops 2021-09-26 13:41:48 +03:00
Vitaliy Filippov d5efbbb6b9 Rename commands and add CLI help 2021-09-26 13:14:36 +03:00
Vitaliy Filippov 4319091bd3 Implement "inverse merge" optimisation 2021-09-26 12:59:04 +03:00
Vitaliy Filippov 6d307d5391 Ignore "readonly" flag when merging snapshots 2021-09-26 11:32:42 +03:00
Vitaliy Filippov 065dfef683 Rename vitastor-cmd to vitastor-cli 2021-09-26 00:52:05 +03:00
Vitaliy Filippov 4d6b85fe67 Split one big cmd.cpp into multiple files 2021-09-26 00:48:08 +03:00
Vitaliy Filippov 2dd2f29f46 Move get_inode_cfg to cli_tool_t 2021-09-25 23:36:45 +03:00
Vitaliy Filippov fc3a1e076a Fix minor bugs in snapshot removal, check it in tests 2021-09-25 19:30:29 +03:00
Vitaliy Filippov 3a3e168c42 Implement high-level snapshot flatten and remove commands 2021-09-25 01:36:44 +03:00
Vitaliy Filippov 95c55da0ad Implement merge with CAS 2021-08-01 20:06:05 +03:00
Vitaliy Filippov 5cf1157f16 Return real version on CAS failure 2021-08-01 20:05:19 +03:00
Vitaliy Filippov acf637950c Implement layer merge
A new command merges multiple snapshot/clone layers into one of them,
so merged layers can be deleted after this procedure
2021-07-31 00:23:30 +03:00
Vitaliy Filippov a02b02eb04 Use new listing methods in rm_inode 2021-07-20 00:19:34 +03:00
Vitaliy Filippov 7d3d696110 Implement object listing with controllable parallelism in cluster_client 2021-07-20 00:19:34 +03:00
Vitaliy Filippov 712576ca75
Merge pull request #13 from lnsyyj/wip-vitastor-debug
fix BLOCKSTORE_DEBUG, error: ‘dirty_it’ was not declared in this scope
2021-07-18 01:25:05 +03:00
Vitaliy Filippov 28bd94d2c2 Make diagnostics slightly better 2021-07-18 01:24:38 +03:00
Vitaliy Filippov 148ff04aa8 Do not lose flusher queue entries when an "older object rescan" happens in parallel with flushing of an older version of another object 2021-07-18 01:20:54 +03:00
JiangYu e86df4a2a2 fix BLOCKSTORE_DEBUG, error: ‘dirty_it’ was not declared in this scope
Signed-off-by: JiangYu <lnsyyj@hotmail.com>
2021-07-18 00:46:05 +08:00
Vitaliy Filippov e74af9745e Print journal flusher diagnostics on slow ops 2021-07-17 16:13:41 +03:00
Vitaliy Filippov 0e0509e3da Dump op states in slow operation log 2021-07-16 01:58:50 +03:00
Vitaliy Filippov cb282d25e0 Release 0.6.5
- Basic support for OpenStack: Cinder driver, patches for Nova and libvirt
- Add missing "image" and "config_path" QEMU options
- Calculate aggregate per-pool statistics in monitor
- Implement writes with Check-And-Set semantics
- Add a C wrapper library with public header
2021-07-10 11:01:21 +03:00
Vitaliy Filippov 8b2a4c9539 Fix centos builds (yum-builddep stopped working in el7, cmake in el8..) 2021-07-10 11:01:21 +03:00
Vitaliy Filippov b66a079892 State basic OpenStack support 2021-07-10 01:11:20 +03:00
Vitaliy Filippov e90bbe6385 Implement OpenStack Cinder driver for Vitastor
It can't delete snapshots yet because Vitastor layer merge isn't
implemented yet. You can only delete volumes with all snapshots.
This will be fixed in the near future.
2021-07-10 01:06:29 +03:00
Vitaliy Filippov 4be761254c Move patches to patches/ 2021-07-09 21:51:19 +03:00
Vitaliy Filippov 7a45c5f86c buster-backports has broken mesa 2021-07-09 12:29:39 +03:00
483 changed files with 81966 additions and 13252 deletions

View File

@ -0,0 +1,36 @@
FROM node:16-bullseye
WORKDIR /root
ADD ./docker/vitastor.gpg /etc/apt/trusted.gpg.d
RUN echo 'deb http://deb.debian.org/debian bullseye-backports main' >> /etc/apt/sources.list; \
echo 'deb http://vitastor.io/debian bullseye main' >> /etc/apt/sources.list; \
echo >> /etc/apt/preferences; \
echo 'Package: *' >> /etc/apt/preferences; \
echo 'Pin: release a=bullseye-backports' >> /etc/apt/preferences; \
echo 'Pin-Priority: 500' >> /etc/apt/preferences; \
echo >> /etc/apt/preferences; \
echo 'Package: *' >> /etc/apt/preferences; \
echo 'Pin: origin "vitastor.io"' >> /etc/apt/preferences; \
echo 'Pin-Priority: 1000' >> /etc/apt/preferences; \
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
RUN apt-get update
RUN apt-get -y install etcd qemu-system-x86 qemu-block-extra qemu-utils fio libasan5 \
liburing1 liburing-dev libgoogle-perftools-dev devscripts libjerasure-dev cmake libibverbs-dev libisal-dev
RUN apt-get -y build-dep fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
RUN apt-get -y install jq lp-solve sudo nfs-common
RUN apt-get --download-only source fio qemu=`dpkg -s qemu-system-x86|grep ^Version:|awk '{print $2}'`
RUN set -ex; \
mkdir qemu-build; \
cd qemu-build; \
dpkg-source -x /root/qemu*.dsc; \
cd qemu*/; \
debian/rules configure-qemu || debian/rules b/configure-stamp; \
cd b/qemu; \
make -j8 config-poison.h || true; \
make -j8 qapi/qapi-builtin-types.h

View File

@ -0,0 +1,19 @@
FROM git.yourcmc.ru/vitalif/vitastor/buildenv
ADD . /root/vitastor
RUN set -e -x; \
mkdir -p /root/fio-build/; \
cd /root/fio-build/; \
dpkg-source -x /root/fio*.dsc; \
cd /root/vitastor; \
ln -s /root/fio-build/fio-*/ ./fio; \
ln -s /root/qemu-build/qemu-*/ ./qemu; \
ls /usr/include/linux/raw.h || cp ./debian/raw.h /usr/include/linux/raw.h; \
cd mon; \
npm install; \
cd ..; \
mkdir build; \
cd build; \
cmake .. -DWITH_ASAN=yes -DWITH_QEMU=yes; \
make -j16

991
.gitea/workflows/test.yml Normal file
View File

@ -0,0 +1,991 @@
name: Test
on:
push:
branches:
- '*'
paths:
- '.gitea/**'
- 'src/**'
- 'mon/**'
- 'json11'
- 'cpp-btree'
- 'tests/**'
env:
BUILDENV_IMAGE: git.yourcmc.ru/vitalif/vitastor/buildenv
TEST_IMAGE: git.yourcmc.ru/vitalif/vitastor/test
OSD_ARGS: '--etcd_quick_timeout 2000'
concurrency:
group: ci-${{ github.ref }}
cancel-in-progress: true
jobs:
buildenv:
runs-on: ubuntu-latest
container: git.yourcmc.ru/vitalif/gitea-ci-dind
steps:
- uses: actions/checkout@v3
- name: Build and push
run: |
set -ex
if ! docker manifest inspect $BUILDENV_IMAGE >/dev/null; then
docker build -t $BUILDENV_IMAGE -f .gitea/workflows/buildenv.Dockerfile .
docker login git.yourcmc.ru -u vitalif -p "${{secrets.TOKEN}}"
docker push $BUILDENV_IMAGE
fi
build:
runs-on: ubuntu-latest
needs: buildenv
container: git.yourcmc.ru/vitalif/gitea-ci-dind
steps:
- uses: actions/checkout@v3
with:
submodules: true
- name: Build and push
run: |
set -ex
if ! docker manifest inspect $TEST_IMAGE:$GITHUB_SHA >/dev/null; then
docker build -t $TEST_IMAGE:$GITHUB_SHA -f .gitea/workflows/test.Dockerfile .
docker login git.yourcmc.ru -u vitalif -p "${{secrets.TOKEN}}"
docker push $TEST_IMAGE:$GITHUB_SHA
fi
make_test:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
# leak sanitizer sometimes crashes
- run: cd /root/vitastor/build && ASAN_OPTIONS=detect_leaks=0 make -j16 test
npm_lint:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- run: cd /root/vitastor/mon && npm run lint
test_add_osd:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: /root/vitastor/tests/test_add_osd.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_cas:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_cas.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_change_pg_count:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_change_pg_count.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_change_pg_count_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=ec /root/vitastor/tests/test_change_pg_count.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_change_pg_size:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_change_pg_size.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_create_nomaxid:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_create_nomaxid.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_etcd_fail:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: /root/vitastor/tests/test_etcd_fail.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_interrupted_rebalance:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: /root/vitastor/tests/test_interrupted_rebalance.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_interrupted_rebalance_imm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: IMMEDIATE_COMMIT=1 /root/vitastor/tests/test_interrupted_rebalance.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_interrupted_rebalance_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: SCHEME=ec /root/vitastor/tests/test_interrupted_rebalance.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_interrupted_rebalance_ec_imm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: SCHEME=ec IMMEDIATE_COMMIT=1 /root/vitastor/tests/test_interrupted_rebalance.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_failure_domain:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_failure_domain.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_snapshot.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=ec /root/vitastor/tests/test_snapshot.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_minsize_1:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_minsize_1.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_move_reappear:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_move_reappear.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_rm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_rm.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot_chain:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_snapshot_chain.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot_chain_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 6
run: SCHEME=ec /root/vitastor/tests/test_snapshot_chain.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot_down:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_snapshot_down.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_snapshot_down_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=ec /root/vitastor/tests/test_snapshot_down.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_splitbrain:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_splitbrain.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_rebalance_verify:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: /root/vitastor/tests/test_rebalance_verify.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_rebalance_verify_imm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: IMMEDIATE_COMMIT=1 /root/vitastor/tests/test_rebalance_verify.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_rebalance_verify_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: SCHEME=ec /root/vitastor/tests/test_rebalance_verify.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_rebalance_verify_ec_imm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: SCHEME=ec IMMEDIATE_COMMIT=1 /root/vitastor/tests/test_rebalance_verify.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_root_node:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_root_node.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_switch_primary:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_switch_primary.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_write:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_write.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_write_xor:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=xor /root/vitastor/tests/test_write.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_write_no_same:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_write_no_same.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_pg_size_2:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: PG_SIZE=2 /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: SCHEME=ec /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_32k_dmj:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_32k_dmj OSD_ARGS="--data_csum_type crc32c --csum_block_size 32k --inmemory_metadata false --inmemory_journal false" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_32k_dj:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_32k_dj OSD_ARGS="--data_csum_type crc32c --csum_block_size 32k --inmemory_journal false" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_32k:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_32k OSD_ARGS="--data_csum_type crc32c --csum_block_size 32k" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_4k_dmj:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_4k_dmj OSD_ARGS="--data_csum_type crc32c --inmemory_metadata false --inmemory_journal false" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_4k_dj:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_4k_dj OSD_ARGS="--data_csum_type crc32c --inmemory_journal false" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_heal_csum_4k:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 10
run: TEST_NAME=csum_4k OSD_ARGS="--data_csum_type crc32c" OFFSET_ARGS=$OSD_ARGS /root/vitastor/tests/test_heal.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_osd_tags:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_osd_tags.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_enospc:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_enospc.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_enospc_xor:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=xor /root/vitastor/tests/test_enospc.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_enospc_imm:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: IMMEDIATE_COMMIT=1 /root/vitastor/tests/test_enospc.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_enospc_imm_xor:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: IMMEDIATE_COMMIT=1 SCHEME=xor /root/vitastor/tests/test_enospc.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub_zero_osd_2:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: ZERO_OSD=2 /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub_xor:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=xor /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub_pg_size_3:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: PG_SIZE=3 /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub_pg_size_6_pg_minsize_4_osd_count_6_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: PG_SIZE=6 PG_MINSIZE=4 OSD_COUNT=6 SCHEME=ec /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_scrub_ec:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: SCHEME=ec /root/vitastor/tests/test_scrub.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done
test_nfs:
runs-on: ubuntu-latest
needs: build
container: ${{env.TEST_IMAGE}}:${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: 3
run: /root/vitastor/tests/test_nfs.sh
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- $i --------"
cat $i
echo ""
done

View File

@ -0,0 +1,79 @@
#!/usr/bin/perl
use strict;
for my $line (<>)
{
if ($line =~ /\.\/(test_[^\.]+)/s)
{
chomp $line;
my $base_name = $1;
my $test_name = $base_name;
my $timeout = 3;
if ($test_name eq 'test_etcd_fail' || $test_name eq 'test_heal' || $test_name eq 'test_add_osd' ||
$test_name eq 'test_interrupted_rebalance' || $test_name eq 'test_rebalance_verify')
{
$timeout = 10;
}
while ($line =~ /([^\s=]+)=(\S+)/gs)
{
if ($1 eq 'TEST_NAME')
{
$test_name = $base_name.'_'.$2;
last;
}
elsif ($1 eq 'SCHEME' && $2 eq 'ec')
{
$test_name .= '_ec';
}
elsif ($1 eq 'SCHEME' && $2 eq 'xor')
{
$test_name .= '_xor';
}
elsif ($1 eq 'IMMEDIATE_COMMIT')
{
$test_name .= '_imm';
}
else
{
$test_name .= '_'.lc($1).'_'.$2;
}
}
if ($test_name eq 'test_snapshot_chain_ec')
{
$timeout = 6;
}
$line =~ s!\./test_!/root/vitastor/tests/test_!;
# Gitea CI doesn't support artifacts yet, lol
#- name: Upload results
# uses: actions/upload-artifact\@v3
# if: always()
# with:
# name: ${test_name}_result
# path: |
# /root/vitastor/testdata
# !/root/vitastor/testdata/*.bin
# retention-days: 5
print <<"EOF"
$test_name:
runs-on: ubuntu-latest
needs: build
container: \${{env.TEST_IMAGE}}:\${{github.sha}}
steps:
- name: Run test
id: test
timeout-minutes: $timeout
run: $line
- name: Print logs
if: always() && steps.test.outcome == 'failure'
run: |
for i in /root/vitastor/testdata/*.log /root/vitastor/testdata/*.txt; do
echo "-------- \$i --------"
cat \$i
echo ""
done
EOF
;
}
}

13
.gitignore vendored
View File

@ -3,16 +3,3 @@
package-lock.json package-lock.json
fio fio
qemu qemu
osd
stub_osd
stub_uring_osd
stub_bench
osd_test
osd_peering_pg_test
dump_journal
nbd_proxy
rm_inode
test_allocator
test_blockstore
test_shit
osd_rmw_test

115
CLA-en.md Normal file
View File

@ -0,0 +1,115 @@
## Contributor License Agreement
> This Agreement is made in the Russian and English languages. **The English
text of Agreement is for informational purposes only** and is not binding
for the Parties.
>
> In the event of a conflict between the provisions of the Russian and
English versions of this Agreement, the **Russian version shall prevail**.
>
> Russian version is published at https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-ru.md
This document represents the offer of Filippov Vitaliy Vladimirovich
("Author"), author and copyright holder of Vitastor software ("Program"),
acknowledged by a certificate of Federal Service for Intellectual
Property of Russian Federation (Rospatent) # 2021617829 dated 20 May 2021,
to "Contributors" to conclude this license agreement as follows
("Agreement" or "Offer").
In accordance with Art. 435, Art. 438 of the Civil Code of the Russian
Federation, this Agreement is an offer and in case of acceptance of the
offer, an agreement is considered concluded on the conditions specified
in the offer.
1. Applicable Terms. \
1.1. "Official Repository" shall mean the computer storage, operated by
the Author, containing all prior and future versions of the Source
Code of the Program, at Internet addresses https://git.yourcmc.ru/vitalif/vitastor/
or https://github.com/vitalif/vitastor/. \
1.2. "Contributions" shall mean results of intellectual activity
(including, but not limited to, source code, libraries, components,
texts, documentation) which can be software or elements of the software
and which are provided by Contributors to the Author for inclusion
in the Program. \
1.3. "Contributor" shall mean a person who provides Contributions to
the Author and agrees with all provisions of this Agreement.
A Сontributor can be: 1) an individual; or 2) a legal entity or an
individual entrepreneur in case when an individual provides Contributions
on behalf of third parties, including on behalf of his employer.
2. Subject of the Agreement. \
2.1. Subject of the Agreement shall be the Contributions sent to the Author by Contributors. \
2.2. The Contributor grants to the Author the right to use Contributions at his own
discretion and without any necessity to get a prior approval from Contributor or
any other third party in any way, under a simple (non-exclusive), royalty-free,
irrevocable license throughout the world by all means not contrary to law, in whole
or as a part of the Program, or other open-source or closed-source computer programs,
products or services (hereinafter -- the "License"), including, but not limited to: \
2.2.1. to execute Contributions and use them for any tasks; \
2.2.2. to publish and distribute Contributions in modified or unmodified form and/or to rent them; \
2.2.3. to modify Contributions, add comments, illustrations or any explanations to Contributions while using them; \
2.2.4. to create other results of intellectual activity based on Contributions, including derivative works and composite works; \
2.2.5. to translate Contributions into other languages, including other programming languages; \
2.2.6. to carry out rental and public display of Contributions; \
2.2.7. to use Contributions under the trade name and/or any trademark or any other label, or without it, as the Author thinks fit; \
2.3. The Contributor grants to the Author the right to sublicense any of the aforementioned
rights to third parties on any terms at the Author's discretion. \
2.4. The License is provided for the entire duration of Contributor's
exclusive intellectual property rights to the Contributions. \
2.5. The Contributor grants to the Author the right to decide how and where to mention,
or to not mention at all, the fact of his authorship, name, nickname and/or company
details when including Contributions into the Program or in any other computer
programs, products or services.
3. Acceptance of the Offer \
3.1. The Contributor may provide Contributions to the Author in the form of
a "Pull Request" in an Official Repository of the Program or by any
other electronic means of communication, including, but not limited to,
E-mail or messenger applications. \
3.2. The acceptance of the Offer shall be the fact of provision of Contributions
to the Author by the Contributor by any means with the following remark:
“I accept Vitastor CLA agreement: https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md”
or “Я принимаю соглашение Vitastor CLA: https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-ru.md”. \
3.3. Date of acceptance of the Offer shall be the date of such provision.
4. Rights and obligations of the parties. \
4.1. The Contributor reserves the right to use Contributions by any lawful means
not contrary to this Agreement. \
4.2. The Author has the right to refuse to include Contributions into the Program
at any moment with no explanation to the Contributor.
5. Representations and Warranties. \
5.1. The person providing Contributions for the purpose of their inclusion
in the Program represents and warrants that he is the Contributor
or legally acts on the Contributor's behalf. Name or company details
of the Contributor shall be provided with the Contribution at the moment
of their provision to the Author. \
5.2. The Contributor represents and warrants that he legally owns exclusive
intellectual property rights to the Contributions. \
5.3. The Contributor represents and warrants that any further use of
Contributions by the Author as provided by Contributor under the terms
of the Agreement does not infringe on intellectual and other rights and
legitimate interests of third parties. \
5.4. The Contributor represents and warrants that he has all rights and legal
capacity needed to accept this Offer; \
5.5. The Contributor represents and warrants that Contributions don't
contain malware or any information considered illegal under the law
of Russian Federation.
6. Termination of the Agreement \
6.1. The Agreement may be terminated at will of both Author and Contributor,
formalised in the written form or if the Agreement is terminated on
reasons prescribed by the law of Russian Federation.
7. Final Clauses \
7.1. The Contributor may optionally sign the Agreement in the written form. \
7.2. The Agreement is deemed to become effective from the Date of signing of
the Agreement and until the expiration of Contributor's exclusive
intellectual property rights to the Contributions. \
7.3. The Author may unilaterally alter the Agreement without informing Contributors.
The new version of the document shall come into effect 3 (three) days after
being published in the Official Repository of the Program at Internet address
[https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md](https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md).
Contributors should keep informed about the actual version of the Agreement themselves. \
7.4. If the Author and the Contributor fail to agree on disputable issues,
disputes shall be referred to the Moscow Arbitration court.

108
CLA-ru.md Normal file
View File

@ -0,0 +1,108 @@
## Лицензионное соглашение с участником
> Данная Оферта написана в Русской и Английской версиях. **Версия на английском
языке предоставляется в информационных целях** и не связывает стороны договора.
>
> В случае несоответствий между положениями Русской и Английской версий Договора,
**Русская версия имеет приоритет**.
>
> Английская версия опубликована по адресу https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md
Настоящий договор-оферта (далее по тексту Оферта, Договор) адресована физическим
и юридическим лицам (далее Участникам) и является официальным публичным предложением
Филиппова Виталия Владимировича (далее Автора) программного обеспечения Vitastor,
свидетельство Федеральной службы по интеллектуальной собственности (Роспатент) № 2021617829
от 20 мая 2021 г. (далее Программа) о нижеследующем:
1. Термины и определения \
1.1. Репозиторий электронное хранилище, содержащее исходный код Программы. \
1.2. Доработка результат интеллектуальной деятельности Участника, включающий
в себя изменения или дополнения к исходному коду Программы, которые Участник
желает включить в состав Программы для дальнейшего использования и распространения
Автором и для этого направляет их Автору. \
1.3. Участник физическое или юридическое лицо, вносящее Доработки в код Программы. \
1.4. ГК РФ Гражданский кодекс Российской Федерации.
2. Предмет оферты \
2.1. Предметом настоящей оферты являются Доработки, отправляемые Участником Автору. \
2.2. Участник предоставляет Автору право использовать Доработки по собственному усмотрению
и без необходимости предварительного согласования с Участником или иным третьим лицом
на условиях простой (неисключительной) безвозмездной безотзывной лицензии, полностью
или фрагментарно, в составе Программы или других программ, продуктов или сервисов
как с открытым, так и с закрытым исходным кодом, любыми способами, не противоречащими
закону, включая, но не ограничиваясь следующими: \
2.2.1. Запускать и использовать Доработки для выполнения любых задач; \
2.2.2. Распространять, импортировать и доводить Доработки до всеобщего сведения; \
2.2.3. Вносить в Доработки изменения, сокращения и дополнения, снабжать Доработки
при их использовании комментариями, иллюстрациями или пояснениями; \
2.2.4. Создавать на основе Доработок иные результаты интеллектуальной деятельности,
в том числе производные и составные произведения; \
2.2.5. Переводить Доработки на другие языки, в том числе на другие языки программирования; \
2.2.6. Осуществлять прокат и публичный показ Доработок; \
2.2.7. Использовать Доработки под любым фирменным наименованием, товарным знаком
(знаком обслуживания) или иным обозначением, или без такового. \
2.3. Участник предоставляет Автору право сублицензировать полученные права на Доработки
третьим лицам на любых условиях на усмотрение Автора. \
2.4. Участник предоставляет Автору права на Доработки на территории всего мира. \
2.5. Участник предоставляет Автору права на весь срок действия исключительного права
Участника на Доработки. \
2.6. Участник предоставляет Автору права на Доработки на безвозмездной основе. \
2.7. Участник разрешает Автору самостоятельно определять порядок, способ и
место указания его имени, реквизитов и/или псевдонима при включении
Доработок в состав Программы или других программ, продуктов или сервисов.
3. Акцепт Оферты \
3.1. Участник может передавать Доработки в адрес Автора через зеркала официального
Репозитория Программы по адресам https://git.yourcmc.ru/vitalif/vitastor/ или
https://github.com/vitalif/vitastor/ в виде “запроса на слияние” (pull request),
либо в письменном виде или с помощью любых других электронных средств коммуникации,
например, электронной почты или мессенджеров. \
3.2. Факт передачи Участником Доработок в адрес Автора любым способом с одной из пометок
“I accept Vitastor CLA agreement: https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-en.md”
или “Я принимаю соглашение Vitastor CLA: https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-ru.md”
является полным и безоговорочным акцептом (принятием) Участником условий настоящей
Оферты, т.е. Участник считается ознакомившимся с настоящим публичным договором и
в соответствии с ГК РФ признается лицом, вступившим с Автором в договорные отношения
на основании настоящей Оферты. \
3.3. Датой акцептирования настоящей Оферты считается дата такой передачи.
4. Права и обязанности Сторон \
4.1. Участник сохраняет за собой право использовать Доработки любым законным
способом, не противоречащим настоящему Договору. \
4.2. Автор вправе отказать Участнику во включении Доработок в состав
Программы без объяснения причин в любой момент по своему усмотрению.
5. Гарантии и заверения \
5.1. Лицо, направляющее Доработки для целей их включения в состав Программы,
гарантирует, что является Участником или представителем Участника. Имя или реквизиты
Участника должны быть указаны при их передаче в адрес Автора Программы. \
5.2. Участник гарантирует, что является законным обладателем исключительных прав
на Доработки. \
5.3. Участник гарантирует, что на момент акцептирования настоящей Оферты ему
ничего не известно (и не могло быть известно) о правах третьих лиц на
передаваемые Автору Доработки или их часть, которые могут быть нарушены
в связи с передачей Доработок по настоящему Договору. \
5.4. Участник гарантирует, что является дееспособным лицом и обладает всеми
необходимыми правами для заключения Договора. \
5.5. Участник гарантирует, что Доработки не содержат вредоносного ПО, а также
любой другой информации, запрещённой к распространению по законам Российской
Федерации.
6. Прекращение действия оферты \
6.1. Действие настоящего договора может быть прекращено по соглашению сторон,
оформленному в письменном виде, а также вследствие его расторжения по основаниям,
предусмотренным законом.
7. Заключительные положения \
7.1. Участник вправе по желанию подписать настоящий Договор в письменном виде. \
7.2. Настоящий договор действует с момента его заключения и до истечения срока
действия исключительных прав Участника на Доработки. \
7.3. Автор имеет право в одностороннем порядке вносить изменения и дополнения в договор
без специального уведомления об этом Участников. Новая редакция документа вступает
в силу через 3 (Три) календарных дня со дня опубликования в официальном Репозитории
Программы по адресу в сети Интернет
[https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-ru.md](https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/CLA-ru.md).
Участники самостоятельно отслеживают действующие условия Оферты. \
7.4. Все споры, возникающие между сторонами в процессе их взаимодействия по настоящему
договору, решаются путём переговоров. В случае невозможности урегулирования споров
переговорным порядком стороны разрешают их в Арбитражном суде г.Москвы.

View File

@ -1,7 +1,7 @@
cmake_minimum_required(VERSION 2.8) cmake_minimum_required(VERSION 2.8.12)
project(vitastor) project(vitastor)
set(VERSION "0.6.4") set(VERSION "1.6.1")
add_subdirectory(src) add_subdirectory(src)

View File

@ -4,545 +4,72 @@
## Идея ## Идея
Я всего лишь хочу сделать качественную блочную SDS! Вернём былую скорость кластерному блочному хранилищу!
Vitastor - распределённая блочная SDS, прямой аналог Ceph RBD и внутренних СХД популярных Vitastor - распределённая блочная и файловая SDS (программная СХД), прямой аналог Ceph RBD и CephFS,
облачных провайдеров. Однако, в отличие от них, Vitastor быстрый и при этом простой. а также внутренних СХД популярных облачных провайдеров. Однако, в отличие от них, Vitastor
Только пока маленький :-). быстрый и при этом простой. Только пока маленький :-).
Архитектурная схожесть с Ceph означает заложенную на уровне алгоритмов записи строгую консистентность, Vitastor архитектурно похож на Ceph, что означает атомарность и строгую консистентность,
репликацию через первичный OSD, симметричную кластеризацию без единой точки отказа репликацию через первичный OSD, симметричную кластеризацию без единой точки отказа
и автоматическое распределение данных по любому числу дисков любого размера с настраиваемыми схемами и автоматическое распределение данных по любому числу дисков любого размера с настраиваемыми схемами
избыточности - репликацией или с произвольными кодами коррекции ошибок. избыточности - репликацией или с произвольными кодами коррекции ошибок.
## Возможности Vitastor нацелен в первую очередь на SSD и SSD+HDD кластеры с как минимум 10 Гбит/с сетью, поддерживает
TCP и RDMA и на хорошем железе может достигать задержки 4 КБ чтения и записи на уровне ~0.1 мс,
Vitastor на данный момент находится в статусе предварительного выпуска, расширенные что примерно в 10 раз быстрее, чем Ceph и другие популярные программные СХД.
возможности пока отсутствуют, а в будущих версиях вероятны "ломающие" изменения.
Vitastor поддерживает QEMU-драйвер, протоколы NBD и NFS, драйверы OpenStack, Proxmox, Kubernetes.
Однако следующее уже реализовано: Другие драйверы могут также быть легко реализованы.
- Базовая часть - надёжное кластерное блочное хранилище без единой точки отказа Подробности смотрите в документации по ссылкам ниже.
- Производительность ;-D
- Несколько схем отказоустойчивости: репликация, XOR n+1 (1 диск чётности), коды коррекции ошибок ## Презентации и записи докладов
Рида-Соломона на основе библиотеки jerasure с любым числом дисков данных и чётности в группе
- Конфигурация через простые человекочитаемые JSON-структуры в etcd - DevOpsConf'2021: презентация ([на русском](https://vitastor.io/presentation/devopsconf/devopsconf.html),
- Автоматическое распределение данных по OSD, с поддержкой: [на английском](https://vitastor.io/presentation/devopsconf/devopsconf_en.html)),
- Математической оптимизации для лучшей равномерности распределения и минимизации перемещений данных [видео](https://vitastor.io/presentation/devopsconf/talk.webm)
- Нескольких пулов с разными схемами избыточности - Highload'2022: презентация ([на русском](https://vitastor.io/presentation/highload/highload.html)),
- Дерева распределения, выбора OSD по тегам / классам устройств (только SSD, только HDD) и по поддереву [видео](https://vitastor.io/presentation/highload/talk.webm)
- Настраиваемых доменов отказа (диск/сервер/стойка и т.п.)
- Восстановление деградированных блоков ## Документация
- Ребаланс, то есть перемещение данных между OSD (дисками)
- Поддержка "ленивого" fsync (fsync не на каждую операцию) - Введение
- Сбор статистики ввода/вывода в etcd - [Быстрый старт](docs/intro/quickstart.ru.md)
- Клиентская библиотека режима пользователя для ввода/вывода - [Возможности](docs/intro/features.ru.md)
- Драйвер диска для QEMU (собирается вне дерева исходников QEMU) - [Архитектура](docs/intro/architecture.ru.md)
- Драйвер диска для утилиты тестирования производительности fio (также собирается вне дерева исходников fio) - [Автор и лицензия](docs/intro/author.ru.md)
- NBD-прокси для монтирования образов ядром ("блочное устройство в режиме пользователя") - Установка
- Утилита удаления образов/инодов (vitastor-rm) - [Пакеты](docs/installation/packages.ru.md)
- Пакеты для Debian и CentOS - [Proxmox](docs/installation/proxmox.ru.md)
- Статистика операций ввода/вывода и занятого места в разрезе инодов - [OpenStack](docs/installation/openstack.ru.md)
- Именование инодов через хранение их метаданных в etcd - [Kubernetes CSI](docs/installation/kubernetes.ru.md)
- Снапшоты и copy-on-write клоны - [Сборка из исходных кодов](docs/installation/source.ru.md)
- Сглаживание производительности случайной записи в SSD+HDD конфигурациях - Конфигурация
- Поддержка RDMA/RoCEv2 через libibverbs - [Обзор](docs/config.ru.md)
- CSI-плагин для Kubernetes - Параметры
- [Общие](docs/config/common.ru.md)
## Планы развития - [Сетевые](docs/config/network.ru.md)
- [Клиентский код](docs/config/client.en.md)
- Более корректные скрипты разметки дисков и автоматического запуска OSD - [Глобальные дисковые параметры](docs/config/layout-cluster.ru.md)
- Другие инструменты администрирования - [Дисковые параметры OSD](docs/config/layout-osd.ru.md)
- Плагины для OpenStack, OpenNebula, Proxmox и других облачных систем - [Прочие параметры OSD](docs/config/osd.ru.md)
- iSCSI-прокси - [Параметры мониторов](docs/config/monitor.ru.md)
- Более быстрое переключение при отказах - [Настройки пулов](docs/config/pool.ru.md)
- Фоновая проверка целостности без контрольных сумм (сверка реплик) - [Метаданные образов в etcd](docs/config/inode.ru.md)
- Контрольные суммы - Использование
- Поддержка SSD-кэширования (tiered storage) - [vitastor-cli](docs/usage/cli.ru.md) (консольный интерфейс)
- Поддержка NVDIMM - [vitastor-disk](docs/usage/disk.ru.md) (управление дисками)
- Web-интерфейс - [fio](docs/usage/fio.ru.md) для тестов производительности
- Возможно, сжатие - [NBD](docs/usage/nbd.ru.md) для монтирования ядром
- Возможно, поддержка кэширования данных через системный page cache - [QEMU и qemu-img](docs/usage/qemu.ru.md)
- [NFS](docs/usage/nfs.ru.md) кластерная файловая система и псевдо-ФС прокси
## Архитектура - [Администрирование](docs/usage/admin.ru.md)
- Производительность
Так же, как и в Ceph, в Vitastor: - [Понимание сути производительности](docs/performance/understanding.ru.md)
- [Теоретический максимум](docs/performance/theoretical.ru.md)
- Есть пулы (pools), PG, OSD, мониторы, домены отказа, дерево распределения (аналог crush-дерева). - [Пример сравнения с Ceph](docs/performance/comparison1.ru.md)
- Образы делятся на блоки фиксированного размера (объекты), и эти объекты распределяются по OSD. - [Более новый тест Vitastor 1.3.1](docs/performance/bench2.ru.md)
- У OSD есть журнал и метаданные и они тоже могут размещаться на отдельных быстрых дисках.
- Все операции записи тоже транзакционны. В Vitastor, правда, есть режим отложенного/ленивого fsync
(коммита), в котором fsync не вызывается на каждую операцию записи, что делает его более
пригодным для использования на "плохих" (десктопных) SSD. Однако все операции записи
в любом случае атомарны.
- Клиентская библиотека тоже старается ждать восстановления после любого отказа кластера, то есть,
вы тоже можете перезагрузить хоть весь кластер разом, и клиенты только на время зависнут,
но не отключатся.
Некоторые базовые термины для тех, кто не знаком с Ceph:
- OSD (Object Storage Daemon) - процесс, который хранит данные на одном диске и обрабатывает
запросы чтения/записи от клиентов.
- Пул (Pool) - контейнер для данных, имеющих одну и ту же схему избыточности и правила распределения по OSD.
- PG (Placement Group) - группа объектов, хранимых на одном и том же наборе реплик (OSD).
Несколько PG могут храниться на одном и том же наборе реплик, но объекты одной PG
в норме не хранятся на разных наборах OSD.
- Монитор - демон, хранящий состояние кластера.
- Домен отказа (Failure Domain) - группа OSD, которым вы разрешаете "упасть" всем вместе.
Иными словами, это группа OSD, в которые СХД не помещает разные копии одного и того же
блока данных. Например, если домен отказа - сервер, то на двух дисках одного сервера
никогда не окажется 2 и более копий одного и того же блока данных, а значит, даже
если в этом сервере откажут все диски, это будет равносильно потере только 1 копии
любого блока данных.
- Дерево распределения (Placement Tree / CRUSH Tree) - иерархическая группировка OSD
в узлы, которые далее можно использовать как домены отказа. То есть, диск (OSD) входит в
сервер, сервер входит в стойку, стойка входит в ряд, ряд в датацентр и т.п.
Чем Vitastor отличается от Ceph:
- Vitastor в первую очередь сфокусирован на SSD. Также Vitastor, вероятно, должен неплохо работать
с комбинацией SSD и HDD через bcache, а в будущем, возможно, будут добавлены и нативные способы
оптимизации под SSD+HDD. Однако хранилище на основе одних лишь жёстких дисков, вообще без SSD,
не в приоритете, поэтому оптимизации под этот кейс могут вообще не состояться.
- OSD Vitastor однопоточный и всегда таким останется, так как это самый оптимальный способ работы.
Если вам не хватает 1 ядра на 1 диск, просто делите диск на разделы и запускайте на нём несколько OSD.
Но, скорее всего, вам хватит и 1 ядра - Vitastor не так прожорлив к ресурсам CPU, как Ceph.
- Журнал и метаданные всегда размещаются в памяти, благодаря чему никогда не тратится лишнее время
на чтение метаданных с диска. Размер метаданных линейно зависит от размера диска и блока данных,
который задаётся в конфигурации кластера и по умолчанию составляет 128 КБ. С блоком 128 КБ метаданные
занимают примерно 512 МБ памяти на 1 ТБ дискового пространства (и это всё равно меньше, чем нужно Ceph-у).
Журнал вообще не должен быть большим, например, тесты производительности в данном документе проводились
с журналом размером всего 16 МБ. Большой журнал, вероятно, даже вреден, т.к. "грязные" записи (записи,
не сброшенные из журнала) тоже занимают память и могут немного замедлять работу.
- В Vitastor нет внутреннего copy-on-write. Я считаю, что реализация CoW-хранилища гораздо сложнее,
поэтому сложнее добиться устойчиво хороших результатов. Возможно, в один прекрасный день
я придумаю красивый алгоритм для CoW-хранилища, но пока нет - внутреннего CoW в Vitastor не будет.
Всё это не относится к "внешнему" CoW (снапшотам и клонам).
- Базовый слой Vitastor - простое блочное хранилище с блоками фиксированного размера, а не сложное
объектное хранилище с расширенными возможностями, как в Ceph (RADOS).
- В Vitastor есть режим "ленивых fsync", в котором OSD группирует запросы записи перед сбросом их
на диск, что позволяет получить лучшую производительность с дешёвыми настольными SSD без конденсаторов
("Advanced Power Loss Protection" / "Capacitor-Based Power Loss Protection").
Тем не менее, такой режим всё равно медленнее использования нормальных серверных SSD и мгновенного
fsync, так как приводит к дополнительным операциям передачи данных по сети, поэтому рекомендуется
всё-таки использовать хорошие серверные диски, тем более, стоят они почти так же, как десктопные.
- PG эфемерны. Это означает, что они не хранятся на дисках и существуют только в памяти работающих OSD.
- Процессы восстановления оперируют отдельными объектами, а не целыми PG.
- PGLOG-ов нет.
- "Мониторы" не хранят данные. Конфигурация и состояние кластера хранятся в etcd в простых человекочитаемых
JSON-структурах. Мониторы Vitastor только следят за состоянием кластера и управляют перемещением данных.
В этом смысле монитор Vitastor не является критичным компонентом системы и больше похож на Ceph-овский
менеджер (MGR). Монитор Vitastor написан на node.js.
- Распределение PG не основано на консистентных хешах. Вместо этого все маппинги PG хранятся прямо в etcd
(ибо нет никакой проблемы сохранить несколько сотен-тысяч записей в памяти, а не считать каждый раз хеши).
Перераспределение PG по OSD выполняется через математическую оптимизацию,
а конкретно, сведение задачи к ЛП (задаче линейного программирования) и решение оной с помощью утилиты
lp_solve. Такой подход позволяет обычно выравнивать распределение места почти идеально - равномерность
обычно составляет 96-99%, в отличие от Ceph, где на голом CRUSH-е без балансировщика обычно выходит 80-90%.
Также это позволяет минимизировать объём перемещения данных и случайность связей между OSD, а также менять
распределение вручную, не боясь сломать логику перебалансировки. В таком подходе есть и потенциальный
недостаток - есть предположение, что в очень большом кластере он может сломаться - однако вплоть до
нескольких сотен OSD подход точно работает нормально. Ну и, собственно, при необходимости легко
реализовать и консистентные хеши.
- Отдельный слой, подобный слою "CRUSH-правил", отсутствует. Вы настраиваете схемы отказоустойчивости,
домены отказа и правила выбора OSD напрямую в конфигурации пулов.
## Понимание сути производительности систем хранения
Вкратце: для быстрой хранилки задержки важнее, чем пиковые iops-ы.
Лучшая возможная задержка достигается при тестировании в 1 поток с глубиной очереди 1,
что приблизительно означает минимально нагруженное состояние кластера. В данном случае
IOPS = 1/задержка. Ни числом серверов, ни дисков, ни серверных процессов/потоков
задержка не масштабируется... Она зависит только от того, насколько быстро один
серверный процесс (и клиент) обрабатывают одну операцию.
Почему задержки важны? Потому, что некоторые приложения *не могут* использовать глубину
очереди больше 1, ибо их задача не параллелизуется. Важный пример - это все СУБД
с поддержкой консистентности (ACID), потому что все они обеспечивают её через
журналирование, а журналы пишутся последовательно и с fsync() после каждой операции.
fsync, кстати - это ещё одна очень важная вещь, про которую почти всегда забывают в тестах.
Смысл в том, что все современные диски имеют кэши/буферы записи и не гарантируют, что
данные реально физически записываются на носитель до того, как вы делаете fsync(),
который транслируется в команду сброса кэша операционной системой.
Дешёвые SSD для настольных ПК и ноутбуков очень быстрые без fsync - NVMe диски, например,
могут обработать порядка 80000 операций записи в секунду с глубиной очереди 1 без fsync.
Однако с fsync, когда они реально вынуждены писать каждый блок данных во флеш-память,
они выжимают лишь 1000-2000 операций записи в секунду (число практически постоянное
для всех моделей SSD).
Серверные SSD часто имеют суперконденсаторы, работающие как встроенный источник
бесперебойного питания и дающие дискам успеть сбросить их DRAM-кэш в постоянную
флеш-память при отключении питания. Благодаря этому диски с чистой совестью
*игнорируют fsync*, так как точно знают, что данные из кэша доедут до постоянной
памяти.
Все наиболее известные программные СХД, например, Ceph и внутренние СХД, используемые
такими облачными провайдерами, как Amazon, Google, Яндекс, медленные в смысле задержки.
В лучшем случае они дают задержки от 0.3мс на чтение и 0.6мс на запись 4 КБ блоками
даже при условии использования наилучшего возможного железа.
И это в эпоху SSD, когда вы можете пойти на рынок и купить там SSD, задержка которого
на чтение будет 0.1мс, а на запись - 0.04мс, за 100$ или даже дешевле.
Когда мне нужно быстро протестировать производительность дисковой подсистемы, я
использую следующие 6 команд, с небольшими вариациями:
- Линейная запись:
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
- Линейное чтение:
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
- Запись в 1 поток (T1Q1):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
- Чтение в 1 поток (T1Q1):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
- Параллельная запись (numjobs используется, когда 1 ядро CPU не может насытить диск):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
- Параллельное чтение (numjobs - аналогично):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
## Теоретическая максимальная производительность Vitastor
При использовании репликации:
- Задержка чтения в 1 поток (T1Q1): 1 сетевой RTT + 1 чтение с диска.
- Запись+fsync в 1 поток:
- С мгновенным сбросом: 2 RTT + 1 запись.
- С отложенным ("ленивым") сбросом: 4 RTT + 1 запись + 1 fsync.
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
- Параллельная запись: сумма IOPS всех дисков / число реплик / WA либо производительность сети, если в сеть упрётся раньше.
При использовании кодов коррекции ошибок (EC):
- Задержка чтения в 1 поток (T1Q1): 1.5 RTT + 1 чтение.
- Запись+fsync в 1 поток:
- С мгновенным сбросом: 3.5 RTT + 1 чтение + 2 записи.
- С отложенным ("ленивым") сбросом: 5.5 RTT + 1 чтение + 2 записи + 2 fsync.
- Под 0.5 на самом деле подразумевается (k-1)/k, где k - число дисков данных,
что означает, что дополнительное обращение по сети не нужно, когда операция
чтения обслуживается локально.
- Параллельное чтение: сумма IOPS всех дисков либо производительность сети, если в сеть упрётся раньше.
- Параллельная запись: сумма IOPS всех дисков / общее число дисков данных и чётности / WA либо производительность сети, если в сеть упрётся раньше.
Примечание: IOPS дисков в данном случае надо брать в смешанном режиме чтения/записи в пропорции, аналогичной формулам выше.
WA (мультипликатор записи) для 4 КБ блоков в Vitastor обычно составляет 3-5:
1. Запись метаданных в журнал
2. Запись блока данных в журнал
3. Запись метаданных в БД
4. Ещё одна запись метаданных в журнал при использовании EC
5. Запись блока данных на диск данных
Если вы найдёте SSD, хорошо работающий с 512-байтными блоками данных (Optane?),
то 1, 3 и 4 можно снизить до 512 байт (1/8 от размера данных) и получить WA всего 2.375.
Кроме того, WA снижается при использовании отложенного/ленивого сброса при параллельной
нагрузке, т.к. блоки журнала записываются на диск только когда они заполняются или явным
образом запрашивается fsync.
## Пример сравнения с Ceph
Железо - 4 сервера, в каждом:
- 6x SATA SSD Intel D3-4510 3.84 TB
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
- 384 GB RAM
- 1x 25 GbE сетевая карта (Mellanox ConnectX-4 LX), подключённая к свитчу Juniper QFX5200
Экономия энергии CPU отключена. В тестах и Vitastor, и Ceph развёрнуто по 2 OSD на 1 SSD.
Все результаты ниже относятся к случайной нагрузке 4 КБ блоками (если явно не указано обратное).
Производительность голых дисков:
- T1Q1 запись ~27000 iops (задержка ~0.037ms)
- T1Q1 чтение ~9800 iops (задержка ~0.101ms)
- T1Q32 запись ~60000 iops
- T1Q32 чтение ~81700 iops
Ceph 15.2.4 (Bluestore):
- T1Q1 запись ~1000 iops (задержка ~1ms)
- T1Q1 чтение ~1750 iops (задержка ~0.57ms)
- T8Q64 запись ~100000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
- T8Q64 чтение ~480000 iops, потребление CPU процессами OSD около 40 ядер на каждом сервере
Тесты в 8 потоков проводились на 8 400GB RBD образах со всех хостов (с каждого хоста запускалось 2 процесса fio).
Это нужно потому, что в Ceph несколько RBD-клиентов, пишущих в 1 образ, очень сильно замедляются.
Настройки RocksDB и Bluestore в Ceph не менялись, единственным изменением было отключение cephx_sign_messages.
На самом деле, результаты теста не такие уж и плохие для Ceph (могло быть хуже).
Собственно говоря, эти серверы как раз хорошо сбалансированы для Ceph - 6 SATA SSD как раз
утилизируют 25-гигабитную сеть, а без 2 мощных процессоров Ceph-у бы не хватило ядер,
чтобы выдать пристойный результат. Собственно, что и показывает жор 40 ядер в процессе
параллельного теста.
Vitastor:
- T1Q1 запись: 7087 iops (задержка 0.14ms)
- T1Q1 чтение: 6838 iops (задержка 0.145ms)
- T2Q64 запись: 162000 iops, потребление CPU - 3 ядра на каждом сервере
- T8Q64 чтение: 895000 iops, потребление CPU - 4 ядра на каждом сервере
- Линейная запись (4M T1Q32): 2800 МБ/с
- Линейное чтение (4M T1Q32): 1500 МБ/с
Тест на чтение в 8 потоков проводился на 1 большом образе (3.2 ТБ) со всех хостов (опять же, по 2 fio с каждого).
В Vitastor никакой разницы между 1 образом и 8-ю нет. Естественно, примерно 1/4 запросов чтения
в такой конфигурации, как и в тестах Ceph выше, обслуживалась с локальной машины. Если проводить
тест так, чтобы все операции всегда обращались к первичным OSD по сети - тест сильнее упирался
в сеть и результат составлял примерно 689000 iops.
Настройки Vitastor: `--disable_data_fsync true --immediate_commit all --flusher_count 8
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
--journal_size 16777216`.
### EC/XOR 2+1
Vitastor:
- T1Q1 запись: 2808 iops (задержка ~0.355ms)
- T1Q1 чтение: 6190 iops (задержка ~0.16ms)
- T2Q64 запись: 85500 iops, потребление CPU - 3.4 ядра на каждом сервере
- T8Q64 чтение: 812000 iops, потребление CPU - 4.7 ядра на каждом сервере
- Линейная запись (4M T1Q32): 3200 МБ/с
- Линейное чтение (4M T1Q32): 1800 МБ/с
Ceph:
- T1Q1 запись: 730 iops (задержка ~1.37ms latency)
- T1Q1 чтение: 1500 iops с холодным кэшем метаданных (задержка ~0.66ms), 2300 iops через 2 минуты прогрева (задержка ~0.435ms)
- T4Q128 запись (4 RBD images): 45300 iops, потребление CPU - 30 ядер на каждом сервере
- T8Q64 чтение (4 RBD images): 278600 iops, потребление CPU - 40 ядер на каждом сервере
- Линейная запись (4M T1Q32): 1950 МБ/с в пустой образ, 2500 МБ/с в заполненный образ
- Линейное чтение (4M T1Q32): 2400 МБ/с
### NBD
NBD расшифровывается как "сетевое блочное устройство", но на самом деле оно также
работает просто как аналог FUSE для блочных устройств, то есть, представляет собой
"блочное устройство в пространстве пользователя".
NBD - на данный момент единственный способ монтировать Vitastor ядром Linux.
NBD немного снижает производительность, так как приводит к дополнительным копированиям
данных между ядром и пространством пользователя. Тем не менее, способ достаточно оптимален,
а производительность случайного доступа вообще затрагивается слабо.
Vitastor с однопоточной NBD прокси на том же стенде:
- T1Q1 запись: 6000 iops (задержка 0.166ms)
- T1Q1 чтение: 5518 iops (задержка 0.18ms)
- T1Q128 запись: 94400 iops
- T1Q128 чтение: 103000 iops
- Линейная запись (4M T1Q128): 1266 МБ/с (в сравнении с 2800 МБ/с через fio)
- Линейное чтение (4M T1Q128): 975 МБ/с (в сравнении с 1500 МБ/с через fio)
## Установка
### Debian
- Добавьте ключ репозитория Vitastor:
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
- Добавьте репозиторий Vitastor в /etc/apt/sources.list:
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
- Для Debian 10 (Buster) также включите репозиторий backports:
`deb http://deb.debian.org/debian buster-backports main`
- Установите пакеты: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
### CentOS
- Добавьте в систему репозиторий Vitastor:
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
- Включите EPEL: `yum/dnf install epel-release`
- Включите дополнительные репозитории CentOS:
- CentOS 7: `yum install centos-release-scl`
- CentOS 8: `dnf install centos-release-advanced-virtualization`
- Включите elrepo-kernel:
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
- Установите пакеты: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
### Установка из исходников
- Установите ядро 5.4 или более новое, для поддержки io_uring. Желательно 5.8 или даже новее,
так как в 5.4 есть как минимум 1 известный баг, ведущий к зависанию с io_uring и контроллером HP SmartArray.
- Установите liburing 0.4 или более новый и его заголовки.
- Установите lp_solve.
- Установите etcd, версии не ниже 3.4.15. Более ранние версии работать не будут из-за различных багов,
например [#12402](https://github.com/etcd-io/etcd/pull/12402). Также вы можете взять версию 3.4.13 с
этим конкретным исправлением из ветки release-3.4 репозитория https://github.com/vitalif/etcd/.
- Установите node.js 10 или новее.
- Установите gcc и g++ 8.x или новее.
- Склонируйте данный репозиторий с подмодулями: `git clone https://yourcmc.ru/git/vitalif/vitastor/`.
- Желательно пересобрать QEMU с патчем, который делает необязательным запуск через LD_PRELOAD.
См `qemu-*.*-vitastor.patch` - выберите версию, наиболее близкую вашей версии QEMU.
- Установите QEMU 3.0 или новее, возьмите исходные коды установленного пакета, начните его пересборку,
через некоторое время остановите её и скопируйте следующие заголовки:
- `<qemu>/include` &rarr; `<vitastor>/qemu/include`
- Debian:
* Берите qemu из основного репозитория
* `<qemu>/b/qemu/config-host.h` &rarr; `<vitastor>/qemu/b/qemu/config-host.h`
* `<qemu>/b/qemu/qapi` &rarr; `<vitastor>/qemu/b/qemu/qapi`
- CentOS 8:
* Берите qemu из репозитория Advanced-Virtualization. Чтобы включить его, запустите
`yum install centos-release-advanced-virtualization.noarch` и далее `yum install qemu`
* `<qemu>/config-host.h` &rarr; `<vitastor>/qemu/b/qemu/config-host.h`
* Для QEMU 3.0+: `<qemu>/qapi` &rarr; `<vitastor>/qemu/b/qemu/qapi`
* Для QEMU 2.0+: `<qemu>/qapi-types.h` &rarr; `<vitastor>/qemu/b/qemu/qapi-types.h`
- `config-host.h` и `qapi` нужны, т.к. в них содержатся автогенерируемые заголовки
- Установите fio 3.7 или новее, возьмите исходники пакета и сделайте на них симлинк с `<vitastor>/fio`.
- Соберите и установите Vitastor командой `mkdir build && cd build && cmake .. && make -j8 && make install`.
Обратите внимание на переменную cmake `QEMU_PLUGINDIR` - под RHEL её нужно установить равной `qemu-kvm`.
## Запуск
Внимание: процедура пока что достаточно нетривиальная, задавать конфигурацию и смещения
на диске нужно почти вручную. Это будет исправлено в ближайшем будущем.
- Желательны SATA SSD или NVMe диски с конденсаторами (серверные SSD). Можно использовать и
десктопные SSD, включив режим отложенного fsync, но производительность однопоточной записи
в этом случае пострадает.
- Быстрая сеть, минимум 10 гбит/с
- Для наилучшей производительности нужно отключить энергосбережение CPU: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
- Пропишите нужные вам значения вверху файлов `/usr/lib/vitastor/mon/make-units.sh` и `/usr/lib/vitastor/mon/make-osd.sh`.
- Создайте юниты systemd для etcd и мониторов: `/usr/lib/vitastor/mon/make-units.sh`
- Создайте юниты для OSD: `/usr/lib/vitastor/mon/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`
- Вы можете поменять параметры OSD в юнитах systemd. Смысл некоторых параметров:
- `disable_data_fsync 1` - отключает fsync, используется с SSD с конденсаторами.
- `immediate_commit all` - используется с SSD с конденсаторами.
- `disable_device_lock 1` - отключает блокировку файла устройства, нужно, только если вы запускаете
несколько OSD на одном блочном устройстве.
- `flusher_count 256` - "flusher" - микропоток, удаляющий старые данные из журнала.
Не волнуйтесь об этой настройке, 256 теперь достаточно практически всегда.
- `disk_alignment`, `journal_block_size`, `meta_block_size` следует установить равными размеру
внутреннего блока SSD. Это почти всегда 4096.
- `journal_no_same_sector_overwrites true` запрещает перезапись одного и того же сектора журнала подряд
много раз в процессе записи. Большинство (99%) SSD не нуждаются в данной опции. Однако выяснилось, что
диски, используемые на одном из тестовых стендов - Intel D3-S4510 - очень сильно не любят такую
перезапись, и для них была добавлена эта опция. Когда данный режим включён, также нужно поднимать
значение `journal_sector_buffer_count`, так как иначе Vitastor не хватит буферов для записи в журнал.
- Запустите все etcd: `systemctl start etcd`
- Создайте глобальную конфигурацию в etcd: `etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
(если все ваши диски - серверные с конденсаторами).
- Создайте пулы: `etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool","scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'`.
Для jerasure EC-пулов конфигурация должна выглядеть так: `2:{"name":"ecpool","scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`.
- Запустите все OSD: `systemctl start vitastor.target`
- Ваш кластер должен быть готов - один из мониторов должен уже сконфигурировать PG, а OSD должны запустить их.
- Вы можете проверить состояние PG прямо в etcd: `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. Все PG должны быть 'active'.
### Задать имя образу
```
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
```
Например:
```
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
```
Если вы зададите parent_id, то образ станет CoW-клоном, т.е. все новые запросы записи пойдут в новый инод, а запросы
чтения будут проверять сначала его, а потом родительские слои по цепочке вверх. Чтобы случайно не перезаписать данные
в родительском слое, вы можете переключить его в режим "только чтение", добавив флаг `"readonly":true` в его запись
метаданных. В таком случае родительский образ становится просто снапшотом.
Таким образом, для создания снапшота вам нужно просто переименовать предыдущий inode (например, из testimg в testimg@0),
сделать его readonly и создать новый слой с исходным именем образа (testimg), ссылающийся на только что переименованный
в качестве родительского.
### Запуск тестов с fio
Пример команды для запуска тестов:
```
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
```
Если вы не хотите обращаться к образу по имени, вместо `-image=testimg` можно указать номер пула, номер инода и размер:
`-pool=1 -inode=1 -size=400G`.
### Загрузить образ диска ВМ в/из Vitastor
Используйте qemu-img и строку `vitastor:etcd_host=<HOST>:image=<IMAGE>` в качестве имени файла диска. Например:
```
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg'
```
Обратите внимание, что если вы используете немодифицированный QEMU, потребуется установить переменную окружения
`LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so`.
Если вы не хотите обращаться к образу по имени, вместо `:image=<IMAGE>` можно указать номер пула, номер инода и размер:
`:pool=<POOL>:inode=<INODE>:size=<SIZE>`.
### Запустить ВМ
Для запуска QEMU используйте опцию `-drive file=vitastor:etcd_host=<HOST>:image=<IMAGE>` (аналогично qemu-img)
и физический размер блока 4 KB.
Например:
```
qemu-system-x86_64 -enable-kvm -m 1024
-drive 'file=vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg',format=raw,if=none,id=drive-virtio-disk0,cache=none
-device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1,write-cache=off,physical_block_size=4096,logical_block_size=512
-vnc 0.0.0.0:0
```
Обращение по номерам (`:pool=<POOL>:inode=<INODE>:size=<SIZE>` вместо `:image=<IMAGE>`) работает аналогично qemu-img.
### Удалить образ
Используйте утилиту vitastor-rm. Например:
```
vitastor-rm --etcd_address 10.115.0.10:2379/v3 --pool 1 --inode 1 --parallel_osds 16 --iodepth 32
```
### NBD
Чтобы создать локальное блочное устройство, используйте NBD. Например:
```
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
```
Команда напечатает название устройства вида /dev/nbd0, которое потом можно будет форматировать
и использовать как обычное блочное устройство.
Для обращения по номеру инода, аналогично другим командам, можно использовать опции
`--pool <POOL> --inode <INODE> --size <SIZE>` вместо `--image testimg`.
### Kubernetes
У Vitastor есть CSI-плагин для Kubernetes, поддерживающий RWO-тома.
Для установки возьмите манифесты из директории [csi/deploy/](csi/deploy/), поместите
вашу конфигурацию подключения к Vitastor в [csi/deploy/001-csi-config-map.yaml](001-csi-config-map.yaml),
настройте StorageClass в [csi/deploy/009-storage-class.yaml](009-storage-class.yaml)
и примените все `NNN-*.yaml` к вашей инсталляции Kubernetes.
```
for i in ./???-*.yaml; do kubectl apply -f $i; done
```
После этого вы сможете создавать PersistentVolume. Пример смотрите в файле [csi/deploy/example-pvc.yaml](csi/deploy/example-pvc.yaml).
## Известные проблемы
- Запросы удаления объектов могут в данный момент приводить к "неполным" объектам в EC-пулах,
если в процессе удаления произойдут отказы OSD или серверов, потому что правильная обработка
запросов удаления в кластере должна быть "трёхфазной", а это пока не реализовано. Если вы
столкнётесь с такой ситуацией, просто повторите запрос удаления.
## Принципы реализации
- Я люблю архитектурно простые решения. Vitastor проектируется именно так и я намерен
и далее следовать данному принципу.
- Если вы пришли сюда за идеальным кодом на C++, вы, вероятно, не по адресу. "Общепринятые"
практики написания C++ кода меня не очень волнуют, так как зачастую, опять-таки, ведут к
излишним усложнениям и код получается красивый... но медленный.
- По той же причине в коде иногда можно встретить велосипеды типа собственного упрощённого
HTTP-клиента для работы с etcd. Зато эти велосипеды маленькие и компактные и не требуют
использования десятка внешних библиотек.
- node.js для монитора - не случайный выбор. Он очень быстрый, имеет встроенную событийную
машину, приятный нейтральный C-подобный язык программирования и развитую инфраструктуру.
## Автор и лицензия ## Автор и лицензия
@ -573,5 +100,5 @@ Vitastor Network Public License 1.1, основанная на GNU GPL 3.0 с д
и также на условиях GNU GPL 2.0 или более поздней версии. Так сделано в целях и также на условиях GNU GPL 2.0 или более поздней версии. Так сделано в целях
совместимости с таким ПО, как QEMU и fio. совместимости с таким ПО, как QEMU и fio.
Вы можете найти полный текст VNPL 1.1 в файле [VNPL-1.1.txt](VNPL-1.1.txt), Вы можете найти полный текст VNPL 1.1 на английском языке в файле [VNPL-1.1.txt](VNPL-1.1.txt),
а GPL 2.0 в файле [GPL-2.0.txt](GPL-2.0.txt). VNPL 1.1 на русском языке в файле [VNPL-1.1-RU.txt](VNPL-1.1-RU.txt), а GPL 2.0 в файле [GPL-2.0.txt](GPL-2.0.txt).

558
README.md
View File

@ -1,499 +1,75 @@
## Vitastor # Vitastor
[Читать на русском](README-ru.md) [Читать на русском](README-ru.md)
## The Idea ## The Idea
Make Software-Defined Block Storage Great Again. Make Clustered Block Storage Fast Again.
Vitastor is a small, simple and fast clustered block storage (storage for VM drives), Vitastor is a distributed block and file SDS, direct replacement of Ceph RBD and CephFS,
architecturally similar to Ceph which means strong consistency, primary-replication, symmetric and also internal SDS's of public clouds. However, in contrast to them, Vitastor is fast
clustering and automatic data distribution over any number of drives of any size and simple at the same time. The only thing is it's slightly young :-).
with configurable redundancy (replication or erasure codes/XOR).
Vitastor is architecturally similar to Ceph which means strong consistency,
## Features primary-replication, symmetric clustering and automatic data distribution over any
number of drives of any size with configurable redundancy (replication or erasure codes/XOR).
Vitastor is currently a pre-release, a lot of features are missing and you can still expect
breaking changes in the future. However, the following is implemented: Vitastor targets primarily SSD and SSD+HDD clusters with at least 10 Gbit/s network,
supports TCP and RDMA and may achieve 4 KB read and write latency as low as ~0.1 ms
- Basic part: highly-available block storage with symmetric clustering and no SPOF with proper hardware which is ~10 times faster than other popular SDS's like Ceph
- Performance ;-D or internal systems of public clouds.
- Multiple redundancy schemes: Replication, XOR n+1, Reed-Solomon erasure codes
based on jerasure library with any number of data and parity drives in a group Vitastor supports QEMU, NBD, NFS protocols, OpenStack, Proxmox, Kubernetes drivers.
- Configuration via simple JSON data structures in etcd More drivers may be created easily.
- Automatic data distribution over OSDs, with support for:
- Mathematical optimization for better uniformity and less data movement Read more details below in the documentation.
- Multiple pools
- Placement tree, OSD selection by tags (device classes) and placement root ## Talks and presentations
- Configurable failure domains
- Recovery of degraded blocks - DevOpsConf'2021: presentation ([in Russian](https://vitastor.io/presentation/devopsconf/devopsconf.html),
- Rebalancing (data movement between OSDs) [in English](https://vitastor.io/presentation/devopsconf/devopsconf_en.html)),
- Lazy fsync support [video](https://vitastor.io/presentation/devopsconf/talk.webm)
- I/O statistics reporting to etcd - Highload'2022: presentation ([in Russian](https://vitastor.io/presentation/highload/highload.html)),
- Generic user-space client library [video](https://vitastor.io/presentation/highload/talk.webm)
- QEMU driver (built out-of-tree)
- Loadable fio engine for benchmarks (also built out-of-tree) ## Documentation
- NBD proxy for kernel mounts
- Inode removal tool (vitastor-rm) - Introduction
- Packaging for Debian and CentOS - [Quick Start](docs/intro/quickstart.en.md)
- Per-inode I/O and space usage statistics - [Features](docs/intro/features.en.md)
- Inode metadata storage in etcd - [Architecture](docs/intro/architecture.en.md)
- Snapshots and copy-on-write image clones - [Author and license](docs/intro/author.en.md)
- Write throttling to smooth random write workloads in SSD+HDD configurations - Installation
- RDMA/RoCEv2 support via libibverbs - [Packages](docs/installation/packages.en.md)
- CSI plugin for Kubernetes - [Proxmox](docs/installation/proxmox.en.md)
- [OpenStack](docs/installation/openstack.en.md)
## Roadmap - [Kubernetes CSI](docs/installation/kubernetes.en.md)
- [Building from Source](docs/installation/source.en.md)
- Better OSD creation and auto-start tools - Configuration
- Other administrative tools - [Overview](docs/config.en.md)
- Plugins for OpenStack, OpenNebula, Proxmox and other cloud systems - Parameter Reference
- iSCSI proxy - [Common](docs/config/common.en.md)
- Faster failover - [Network](docs/config/network.en.md)
- Scrubbing without checksums (verification of replicas) - [Client](docs/config/client.en.md)
- Checksums - [Global Disk Layout](docs/config/layout-cluster.en.md)
- Tiered storage - [OSD Disk Layout](docs/config/layout-osd.en.md)
- NVDIMM support - [OSD Runtime Parameters](docs/config/osd.en.md)
- Web GUI - [Monitor](docs/config/monitor.en.md)
- Compression (possibly) - [Pool configuration](docs/config/pool.en.md)
- Read caching using system page cache (possibly) - [Image metadata in etcd](docs/config/inode.en.md)
- Usage
## Architecture - [vitastor-cli](docs/usage/cli.en.md) (command-line interface)
- [vitastor-disk](docs/usage/disk.en.md) (disk management tool)
Similarities: - [fio](docs/usage/fio.en.md) for benchmarks
- [NBD](docs/usage/nbd.en.md) for kernel mounts
- Just like Ceph, Vitastor has Pools, PGs, OSDs, Monitors, Failure Domains, Placement Tree. - [QEMU and qemu-img](docs/usage/qemu.en.md)
- Just like Ceph, Vitastor is transactional (even though there's a "lazy fsync mode" which - [NFS](docs/usage/nfs.en.md) clustered file system and pseudo-FS proxy
doesn't implicitly flush every operation to disks). - [Administration](docs/usage/admin.en.md)
- OSDs also have journal and metadata and they can also be put on separate drives. - Performance
- Just like in Ceph, client library attempts to recover from any cluster failure so - [Understanding storage performance](docs/performance/understanding.en.md)
you can basically reboot the whole cluster and only pause, but not crash, your clients - [Theoretical performance](docs/performance/theoretical.en.md)
(I consider this a bug if the client crashes in that case). - [Example comparison with Ceph](docs/performance/comparison1.en.md)
- [Newer benchmark of Vitastor 1.3.1](docs/performance/bench2.en.md)
Some basic terms for people not familiar with Ceph:
- OSD (Object Storage Daemon) is a process that stores data and serves read/write requests.
- PG (Placement Group) is a container for data that (normally) shares the same replicas.
- Pool is a container for data that has the same redundancy scheme and placement rules.
- Monitor is a separate daemon that watches cluster state and handles failures.
- Failure Domain is a group of OSDs that you allow to fail. It's "host" by default.
- Placement Tree groups OSDs in a hierarchy to later split them into Failure Domains.
Architectural differences from Ceph:
- Vitastor's primary focus is on SSDs. Proper SSD+HDD optimizations may be added in the future, though.
- Vitastor OSD is (and will always be) single-threaded. If you want to dedicate more than 1 core
per drive you should run multiple OSDs each on a different partition of the drive.
Vitastor isn't CPU-hungry though (as opposed to Ceph), so 1 core is sufficient in a lot of cases.
- Metadata and journal are always kept in memory. Metadata size depends linearly on drive capacity
and data store block size which is 128 KB by default. With 128 KB blocks metadata should occupy
around 512 MB per 1 TB (which is still less than Ceph wants). Journal doesn't have to be big,
the example test below was conducted with only 16 MB journal. A big journal is probably even
harmful as dirty write metadata also take some memory.
- Vitastor storage layer doesn't have internal copy-on-write or redirect-write. I know that maybe
it's possible to create a good copy-on-write storage, but it's much harder and makes performance
less deterministic, so CoW isn't used in Vitastor.
- The basic layer of Vitastor is block storage with fixed-size blocks, not object storage with
rich semantics like in Ceph (RADOS).
- There's a "lazy fsync" mode which allows to batch writes before flushing them to the disk.
This allows to use Vitastor with desktop SSDs, but still lowers performance due to additional
network roundtrips, so use server SSDs with capacitor-based power loss protection
("Advanced Power Loss Protection") for best performance.
- PGs are ephemeral. This means that they aren't stored on data disks and only exist in memory
while OSDs are running.
- Recovery process is per-object (per-block), not per-PG. Also there are no PGLOGs.
- Monitors don't store data. Cluster configuration and state is stored in etcd in simple human-readable
JSON structures. Monitors only watch cluster state and handle data movement.
Thus Vitastor's Monitor isn't a critical component of the system and is more similar to Ceph's Manager.
Vitastor's Monitor is implemented in node.js.
- PG distribution isn't based on consistent hashes. All PG mappings are stored in etcd.
Rebalancing PGs between OSDs is done by mathematical optimization - data distribution problem
is reduced to a linear programming problem and solved by lp_solve. This allows for almost
perfect (96-99% uniformity compared to Ceph's 80-90%) data distribution in most cases, ability
to map PGs by hand without breaking rebalancing logic, reduced OSD peer-to-peer communication
(on average, OSDs have fewer peers) and less data movement. It also probably has a drawback -
this method may fail in very large clusters, but up to several hundreds of OSDs it's perfectly fine.
It's also easy to add consistent hashes in the future if something proves their necessity.
- There's no separate CRUSH layer. You select pool redundancy scheme, placement root, failure domain
and so on directly in pool configuration.
## Understanding Storage Performance
The most important thing for fast storage is latency, not parallel iops.
The best possible latency is achieved with one thread and queue depth of 1 which basically means
"client load as low as possible". In this case IOPS = 1/latency, and this number doesn't
scale with number of servers, drives, server processes or threads and so on.
Single-threaded IOPS and latency numbers only depend on *how fast a single daemon is*.
Why is it important? It's important because some of the applications *can't* use
queue depth greater than 1 because their task isn't parallelizable. A notable example
is any ACID DBMS because all of them write their WALs sequentially with fsync()s.
fsync, by the way, is another important thing often missing in benchmarks. The point is
that drives have cache buffers and don't guarantee that your data is actually persisted
until you call fsync() which is translated to a FLUSH CACHE command by the OS.
Desktop SSDs are very fast without fsync - NVMes, for example, can process ~80000 write
operations per second with queue depth of 1 without fsync - but they're really slow with
fsync because they have to actually write data to flash chips when you call fsync. Typical
number is around 1000-2000 iops with fsync.
Server SSDs often have supercapacitors that act as a built-in UPS and allow the drive
to flush its DRAM cache to the persistent flash storage when a power loss occurs.
This makes them perform equally well with and without fsync. This feature is called
"Advanced Power Loss Protection" by Intel; other vendors either call it similarly
or directly as "Full Capacitor-Based Power Loss Protection".
All software-defined storages that I currently know are slow in terms of latency.
Notable examples are Ceph and internal SDSes used by cloud providers like Amazon, Google,
Yandex and so on. They're all slow and can only reach ~0.3ms read and ~0.6ms 4 KB write latency
with best-in-slot hardware.
And that's in the SSD era when you can buy an SSD that has ~0.04ms latency for 100 $.
I use the following 6 commands with small variations to benchmark any storage:
- Linear write:
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=write -runtime=60 -filename=/dev/sdX`
- Linear read:
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4M -iodepth=32 -rw=read -runtime=60 -filename=/dev/sdX`
- Random write latency (T1Q1, this hurts storages the most):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -fsync=1 -rw=randwrite -runtime=60 -filename=/dev/sdX`
- Random read latency (T1Q1):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=1 -rw=randread -runtime=60 -filename=/dev/sdX`
- Parallel write iops (use numjobs if a single CPU core is insufficient to saturate the load):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randwrite -runtime=60 -filename=/dev/sdX`
- Parallel read iops (use numjobs if a single CPU core is insufficient to saturate the load):
`fio -ioengine=libaio -direct=1 -invalidate=1 -name=test -bs=4k -iodepth=128 [-numjobs=4 -group_reporting] -rw=randread -runtime=60 -filename=/dev/sdX`
## Vitastor's Theoretical Maximum Random Access Performance
Replicated setups:
- Single-threaded (T1Q1) read latency: 1 network roundtrip + 1 disk read.
- Single-threaded write+fsync latency:
- With immediate commit: 2 network roundtrips + 1 disk write.
- With lazy commit: 4 network roundtrips + 1 disk write + 1 disk flush.
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops / number of replicas / write amplification)).
EC/XOR setups:
- Single-threaded (T1Q1) read latency: 1.5 network roundtrips + 1 disk read.
- Single-threaded write+fsync latency:
- With immediate commit: 3.5 network roundtrips + 1 disk read + 2 disk writes.
- With lazy commit: 5.5 network roundtrips + 1 disk read + 2 disk writes + 2 disk fsyncs.
- 0.5 in actually (k-1)/k which means that an additional roundtrip doesn't happen when
the read sub-operation can be served locally.
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops * number of data drives / (number of data + parity drives) / write amplification)).
In fact, you should put disk write iops under the condition of ~10% reads / ~90% writes in this formula.
Write amplification for 4 KB blocks is usually 3-5 in Vitastor:
1. Journal block write
2. Journal data write
3. Metadata block write
4. Another journal block write for EC/XOR setups
5. Data block write
If you manage to get an SSD which handles 512 byte blocks well (Optane?) you may
lower 1, 3 and 4 to 512 bytes (1/8 of data size) and get WA as low as 2.375.
Lazy fsync also reduces WA for parallel workloads because journal blocks are only
written when they fill up or fsync is requested.
## Example Comparison with Ceph
Hardware configuration: 4 nodes, each with:
- 6x SATA SSD Intel D3-4510 3.84 TB
- 2x Xeon Gold 6242 (16 cores @ 2.8 GHz)
- 384 GB RAM
- 1x 25 GbE network interface (Mellanox ConnectX-4 LX), connected to a Juniper QFX5200 switch
CPU powersaving was disabled. Both Vitastor and Ceph were configured with 2 OSDs per 1 SSD.
All of the results below apply to 4 KB blocks and random access (unless indicated otherwise).
Raw drive performance:
- T1Q1 write ~27000 iops (~0.037ms latency)
- T1Q1 read ~9800 iops (~0.101ms latency)
- T1Q32 write ~60000 iops
- T1Q32 read ~81700 iops
Ceph 15.2.4 (Bluestore):
- T1Q1 write ~1000 iops (~1ms latency)
- T1Q1 read ~1750 iops (~0.57ms latency)
- T8Q64 write ~100000 iops, total CPU usage by OSDs about 40 virtual cores on each node
- T8Q64 read ~480000 iops, total CPU usage by OSDs about 40 virtual cores on each node
T8Q64 tests were conducted over 8 400GB RBD images from all hosts (every host was running 2 instances of fio).
This is because Ceph has performance penalties related to running multiple clients over a single RBD image.
cephx_sign_messages was set to false during tests, RocksDB and Bluestore settings were left at defaults.
In fact, not that bad for Ceph. These servers are an example of well-balanced Ceph nodes.
However, CPU usage and I/O latency were through the roof, as usual.
Vitastor:
- T1Q1 write: 7087 iops (0.14ms latency)
- T1Q1 read: 6838 iops (0.145ms latency)
- T2Q64 write: 162000 iops, total CPU usage by OSDs about 3 virtual cores on each node
- T8Q64 read: 895000 iops, total CPU usage by OSDs about 4 virtual cores on each node
- Linear write (4M T1Q32): 2800 MB/s
- Linear read (4M T1Q32): 1500 MB/s
T8Q64 read test was conducted over 1 larger inode (3.2T) from all hosts (every host was running 2 instances of fio).
Vitastor has no performance penalties related to running multiple clients over a single inode.
If conducted from one node with all primary OSDs moved to other nodes the result was slightly lower (689000 iops),
this is because all operations resulted in network roundtrips between the client and the primary OSD.
When fio was colocated with OSDs (like in Ceph benchmarks above), 1/4 of the read workload actually
used the loopback network.
Vitastor was configured with: `--disable_data_fsync true --immediate_commit all --flusher_count 8
--disk_alignment 4096 --journal_block_size 4096 --meta_block_size 4096
--journal_no_same_sector_overwrites true --journal_sector_buffer_count 1024
--journal_size 16777216`.
### EC/XOR 2+1
Vitastor:
- T1Q1 write: 2808 iops (~0.355ms latency)
- T1Q1 read: 6190 iops (~0.16ms latency)
- T2Q64 write: 85500 iops, total CPU usage by OSDs about 3.4 virtual cores on each node
- T8Q64 read: 812000 iops, total CPU usage by OSDs about 4.7 virtual cores on each node
- Linear write (4M T1Q32): 3200 MB/s
- Linear read (4M T1Q32): 1800 MB/s
Ceph:
- T1Q1 write: 730 iops (~1.37ms latency)
- T1Q1 read: 1500 iops with cold cache (~0.66ms latency), 2300 iops after 2 minute metadata cache warmup (~0.435ms latency)
- T4Q128 write (4 RBD images): 45300 iops, total CPU usage by OSDs about 30 virtual cores on each node
- T8Q64 read (4 RBD images): 278600 iops, total CPU usage by OSDs about 40 virtual cores on each node
- Linear write (4M T1Q32): 1950 MB/s before preallocation, 2500 MB/s after preallocation
- Linear read (4M T1Q32): 2400 MB/s
### NBD
NBD is currently required to mount Vitastor via kernel, but it imposes additional overhead
due to additional copying between the kernel and userspace. This mostly hurts linear
bandwidth, not iops.
Vitastor with single-thread NBD on the same hardware:
- T1Q1 write: 6000 iops (0.166ms latency)
- T1Q1 read: 5518 iops (0.18ms latency)
- T1Q128 write: 94400 iops
- T1Q128 read: 103000 iops
- Linear write (4M T1Q128): 1266 MB/s (compared to 2800 MB/s via fio)
- Linear read (4M T1Q128): 975 MB/s (compared to 1500 MB/s via fio)
## Installation
### Debian
- Trust Vitastor package signing key:
`wget -q -O - https://vitastor.io/debian/pubkey | sudo apt-key add -`
- Add Vitastor package repository to your /etc/apt/sources.list:
- Debian 11 (Bullseye/Sid): `deb https://vitastor.io/debian bullseye main`
- Debian 10 (Buster): `deb https://vitastor.io/debian buster main`
- For Debian 10 (Buster) also enable backports repository:
`deb http://deb.debian.org/debian buster-backports main`
- Install packages: `apt update; apt install vitastor lp-solve etcd linux-image-amd64 qemu`
### CentOS
- Add Vitastor package repository:
- CentOS 7: `yum install https://vitastor.io/rpms/centos/7/vitastor-release-1.0-1.el7.noarch.rpm`
- CentOS 8: `dnf install https://vitastor.io/rpms/centos/8/vitastor-release-1.0-1.el8.noarch.rpm`
- Enable EPEL: `yum/dnf install epel-release`
- Enable additional CentOS repositories:
- CentOS 7: `yum install centos-release-scl`
- CentOS 8: `dnf install centos-release-advanced-virtualization`
- Enable elrepo-kernel:
- CentOS 7: `yum install https://www.elrepo.org/elrepo-release-7.el7.elrepo.noarch.rpm`
- CentOS 8: `dnf install https://www.elrepo.org/elrepo-release-8.el8.elrepo.noarch.rpm`
- Install packages: `yum/dnf install vitastor lpsolve etcd kernel-ml qemu-kvm`
### Building from Source
- Install Linux kernel 5.4 or newer, for io_uring support. 5.8 or later is highly recommended because
there is at least one known io_uring hang with 5.4 and an HP SmartArray controller.
- Install liburing 0.4 or newer and its headers.
- Install lp_solve.
- Install etcd, at least version 3.4.15. Earlier versions won't work because of various bugs,
for example [#12402](https://github.com/etcd-io/etcd/pull/12402). You can also take 3.4.13
with this specific fix from here: https://github.com/vitalif/etcd/, branch release-3.4.
- Install node.js 10 or newer.
- Install gcc and g++ 8.x or newer.
- Clone https://yourcmc.ru/git/vitalif/vitastor/ with submodules.
- Install QEMU 3.0+, get its source, begin to build it, stop the build and copy headers:
- `<qemu>/include` &rarr; `<vitastor>/qemu/include`
- Debian:
* Use qemu packages from the main repository
* `<qemu>/b/qemu/config-host.h` &rarr; `<vitastor>/qemu/b/qemu/config-host.h`
* `<qemu>/b/qemu/qapi` &rarr; `<vitastor>/qemu/b/qemu/qapi`
- CentOS 8:
* Use qemu packages from the Advanced-Virtualization repository. To enable it, run
`yum install centos-release-advanced-virtualization.noarch` and then `yum install qemu`
* `<qemu>/config-host.h` &rarr; `<vitastor>/qemu/b/qemu/config-host.h`
* For QEMU 3.0+: `<qemu>/qapi` &rarr; `<vitastor>/qemu/b/qemu/qapi`
* For QEMU 2.0+: `<qemu>/qapi-types.h` &rarr; `<vitastor>/qemu/b/qemu/qapi-types.h`
- `config-host.h` and `qapi` are required because they contain generated headers
- You can also rebuild QEMU with a patch that makes LD_PRELOAD unnecessary to load vitastor driver.
See `qemu-*.*-vitastor.patch`.
- Install fio 3.7 or later, get its source and symlink it into `<vitastor>/fio`.
- Build & install Vitastor with `mkdir build && cd build && cmake .. && make -j8 && make install`.
Pay attention to the `QEMU_PLUGINDIR` cmake option - it must be set to `qemu-kvm` on RHEL.
## Running
Please note that startup procedure isn't currently simple - you specify configuration
and calculate disk offsets almost by hand. This will be fixed in near future.
- Get some SATA or NVMe SSDs with capacitors (server-grade drives). You can use desktop SSDs
with lazy fsync, but prepare for inferior single-thread latency.
- Get a fast network (at least 10 Gbit/s).
- Disable CPU powersaving: `cpupower idle-set -D 0 && cpupower frequency-set -g performance`.
- Check `/usr/lib/vitastor/mon/make-units.sh` and `/usr/lib/vitastor/mon/make-osd.sh` and
put desired values into the variables at the top of these files.
- Create systemd units for the monitor and etcd: `/usr/lib/vitastor/mon/make-units.sh`
- Create systemd units for your OSDs: `/usr/lib/vitastor/mon/make-osd.sh /dev/disk/by-partuuid/XXX [/dev/disk/by-partuuid/YYY ...]`
- You can edit the units and change OSD configuration. Notable configuration variables:
- `disable_data_fsync 1` - only safe with server-grade drives with capacitors.
- `immediate_commit all` - use this if all your drives are server-grade.
- `disable_device_lock 1` - only required if you run multiple OSDs on one block device.
- `flusher_count 256` - flusher is a micro-thread that removes old data from the journal.
You don't have to worry about this parameter anymore, 256 is enough.
- `disk_alignment`, `journal_block_size`, `meta_block_size` should be set to the internal
block size of your SSDs which is 4096 on most drives.
- `journal_no_same_sector_overwrites true` prevents multiple overwrites of the same journal sector.
Most (99%) SSDs don't need this option. But Intel D3-4510 does because it doesn't like when you
overwrite the same sector twice in a short period of time. The setting forces Vitastor to never
overwrite the same journal sector twice in a row which makes D3-4510 almost happy. Not totally
happy, because overwrites of the same block can still happen in the metadata area... When this
setting is set, it is also required to raise `journal_sector_buffer_count` setting, which is the
number of dirty journal sectors that may be written to at the same time.
- `systemctl start vitastor.target` everywhere.
- Create global configuration in etcd: `etcdctl --endpoints=... put /vitastor/config/global '{"immediate_commit":"all"}'`
(if all your drives have capacitors).
- Create pool configuration in etcd: `etcdctl --endpoints=... put /vitastor/config/pools '{"1":{"name":"testpool","scheme":"replicated","pg_size":2,"pg_minsize":1,"pg_count":256,"failure_domain":"host"}}'`.
For jerasure pools the configuration should look like the following: `2:{"name":"ecpool","scheme":"jerasure","pg_size":4,"parity_chunks":2,"pg_minsize":2,"pg_count":256,"failure_domain":"host"}`.
- At this point, one of the monitors will configure PGs and OSDs will start them.
- You can check PG states with `etcdctl --endpoints=... get --prefix /vitastor/pg/state`. All PGs should become 'active'.
### Name an image
```
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
```
For example:
```
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
```
If you specify parent_id the image becomes a CoW clone. I.e. all writes go to the new inode and reads first check it
and then upper layers. You can then make parent readonly by updating its entry with `"readonly":true` for safety and
basically treat it as a snapshot.
So to create a snapshot you basically rename the previous upper layer (for example from testimg to testimg@0), make it readonly
and create a new top layer with the original name (testimg) and the previous one as a parent.
### Run fio benchmarks
fio command example:
```
fio -thread -ioengine=libfio_vitastor.so -name=test -bs=4M -direct=1 -iodepth=16 -rw=write -etcd=10.115.0.10:2379/v3 -image=testimg
```
If you don't want to access your image by name, you can specify pool number, inode number and size
(`-pool=1 -inode=1 -size=400G`) instead of the image name (`-image=testimg`).
### Upload VM image
Use qemu-img and `vitastor:etcd_host=<HOST>:image=<IMAGE>` disk filename. For example:
```
qemu-img convert -f qcow2 debian10.qcow2 -p -O raw 'vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg'
```
Note that the command requires to be run with `LD_PRELOAD=/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so qemu-img ...`
if you use unmodified QEMU.
You can also specify `:pool=<POOL>:inode=<INODE>:size=<SIZE>` instead of `:image=<IMAGE>`
if you don't want to use inode metadata.
### Start a VM
Run QEMU with `-drive file=vitastor:etcd_host=<HOST>:image=<IMAGE>` and use 4 KB physical block size.
For example:
```
qemu-system-x86_64 -enable-kvm -m 1024
-drive 'file=vitastor:etcd_host=10.115.0.10\:2379/v3:image=testimg',format=raw,if=none,id=drive-virtio-disk0,cache=none
-device virtio-blk-pci,scsi=off,bus=pci.0,addr=0x5,drive=drive-virtio-disk0,id=virtio-disk0,bootindex=1,write-cache=off,physical_block_size=4096,logical_block_size=512
-vnc 0.0.0.0:0
```
You can also specify `:pool=<POOL>:inode=<INODE>:size=<SIZE>` instead of `:image=<IMAGE>`,
just like in qemu-img.
### Remove inode
Use vitastor-rm. For example:
```
vitastor-rm --etcd_address 10.115.0.10:2379/v3 --pool 1 --inode 1 --parallel_osds 16 --iodepth 32
```
### NBD
To create a local block device for a Vitastor image, use NBD. For example:
```
vitastor-nbd map --etcd_address 10.115.0.10:2379/v3 --image testimg
```
It will output the device name, like /dev/nbd0 which you can then format and mount as a normal block device.
Again, you can use `--pool <POOL> --inode <INODE> --size <SIZE>` insteaf of `--image <IMAGE>` if you want.
### Kubernetes
Vitastor has a CSI plugin for Kubernetes which supports RWO volumes.
To deploy it, take manifests from [csi/deploy/](csi/deploy/) directory, put your
Vitastor configuration in [csi/deploy/001-csi-config-map.yaml](001-csi-config-map.yaml),
configure storage class in [csi/deploy/009-storage-class.yaml](009-storage-class.yaml)
and apply all `NNN-*.yaml` manifests to your Kubernetes installation:
```
for i in ./???-*.yaml; do kubectl apply -f $i; done
```
After that you'll be able to create PersistentVolumes. See example in [csi/deploy/example-pvc.yaml](csi/deploy/example-pvc.yaml).
## Known Problems
- Object deletion requests may currently lead to 'incomplete' objects in EC pools
if your OSDs crash during deletion because proper handling of object cleanup
in a cluster should be "three-phase" and it's currently not implemented.
Just repeat the removal request again in this case.
## Implementation Principles
- I like architecturally simple solutions. Vitastor is and will always be designed
exactly like that.
- I also like reinventing the wheel to some extent, like writing my own HTTP client
for etcd interaction instead of using prebuilt libraries, because in this case
I'm confident about what my code does and what it doesn't do.
- I don't care about C++ "best practices" like RAII or proper inheritance or usage of
smart pointers or whatever and I don't intend to change my mind, so if you're here
looking for ideal reference C++ code, this probably isn't the right place.
- I like node.js better than any other dynamically-typed language interpreter
because it's faster than any other interpreter in the world, has neutral C-like
syntax and built-in event loop. That's why Monitor is implemented in node.js.
## Author and License ## Author and License

680
VNPL-1.1-RU.txt Normal file
View File

@ -0,0 +1,680 @@
СЕТЕВАЯ ПУБЛИЧНАЯ ЛИЦЕНЗИЯ VITASTOR
VITASTOR NETWORK PUBLIC LICENSE
Версия 1.1, от 6 февраля 2021
Автор лицензии: Виталий Филиппов <vitalif@yourcmc.ru>, 2021 год
Каждый имеет право копировать и распространять точные копии этой
лицензии, но без внесения изменений.
ПРЕАМБУЛА
Сетевая Публичная Лицензия Vitastor - это свободная "копилефт" лицензия для
для программного обеспечения (ПО) и других видов произведений, специально
разработанная, чтобы гарантировать кооперацию с сообществом при разработке
сетевых приложений.
Большинство лицензий на программное обеспечение и другие произведения
спроектированы так, чтобы лишить Вас свободы делиться ими и изменять их.
Сетевая Публичная Лицензия Vitastor, напротив, разработана с целью
гарантировать Ваше право распространять и вносить изменения во все версии
программного обеспечения -- для уверенности, что ПО останется свободным для
всех пользователей.
Когда мы говорим о свободном ПО, мы имеем в виду свободу использования, а не
бесплатность. Свободные лицензии, такие, как Сетевая Публичная Лицензия
Vitastor, составлены для того, чтобы убедиться, что у Вас есть право
распространять копии свободного ПО (и взимать плату за них, если Вы хотите),
что Вы получаете исходные тексты или можете получить их, если захотите, что Вы
можете изменять программное обеспечение или использовать его части в новых
свободных программах, и что Вы знаете о своем праве делать всё это.
Разработчики, использующие Сетевую Публичную Лицензию Vitastor, гарантируют
Ваши права при помощи следующих мер: (1) закрепляют авторское право на
программное обеспечение, и (2) предлагают Вам принять условия настоящей
Лицензии, закрепляющей Ваше право на создание копий, распространение и (или)
модификацию программного обеспечения.
Еще одно преимущество защиты свободы всех пользователей заключается в том,
что улучшения, сделанные в разных версиях программы, при их широком
распространении становятся доступными для использования другими разработчиками.
Многие разработчики программного обеспечения воодушевляются этим
сотрудничеством и пользуются его преимуществами. Однако, если программное
обеспечение используется на сетевых серверах, данный результат не всегда
достигается. Генеральная публичная лицензия GNU разрешает создание измененных
версий и предоставление неограниченного доступа к ним, не делая общедоступным
их исходный текст. Даже генеральная публичная лицензия GNU Affero разрешает
использование модифицированной версии свободной программы в закрытой среде, где
внешние пользователи взаимодействуют с ней только через закрытый промежуточный
интерфейс (прокси), опять же, без открытия в свободный публичный доступ как
самой программы, так и прокси.
Сетевая Публичная Лицензия Vitastor разработана специально, чтобы
гарантировать, что в таких случаях и модифицированная версия программы, и
прокси останутся доступными сообществу. Для этого лицензия требует от
операторов сетевых серверов предоставлять исходный код оригинальной программы,
а также всех других программ, взаимодействующих с ней на их серверах,
пользователям этих серверов, на условиях свободных лицензий. Таким образом,
публичное использование изменённой версии ПО на сервере, прямо или косвенно
доступном пользователям, даёт пользователям доступ к исходным кодам изменённой
версии.
Детальные определения используемых терминов и описание условий копирования,
распространения и внесения изменений приведены ниже.
ТЕРМИНЫ И УСЛОВИЯ
0. Определения.
"Настоящая Лицензия" -- версия 1.1 Сетевой Публичной Лицензии Vitastor.
Под "Авторским правом" понимаются все законы, сходные с авторско-правовыми,
которые применяются к любым видам работ, например, к топологиям микросхем.
Термином "Программа" обозначается любое охраноспособное произведение,
используемое в соответствии с настоящей Лицензией. Лицензиат именуется "Вы".
"Лицензиаты" и "получатели" могут быть как физическими лицами, так и
организациями.
"Внесение изменений" в произведение означает копирование или адаптацию
произведения целиком или в части, способом, требующим разрешения
правообладателя, за исключением изготовления его точной копии. Получившееся
произведение называется "измененной версией" предыдущего произведения или
произведением, "основанным на" более ранней работе.
Термином "Лицензионное произведение" обозначается неизмененная Программа или
произведение, основанное на Программе.
"Распространение" произведения означает совершение с ним действий, которые
при отсутствии разрешения сделают Вас прямо или косвенно ответственным за
нарушение действующего закона об авторском праве, за исключением запуска на
компьютере или изменения копии, созданной в личных целях. Распространение
включает в себя копирование, раздачу копий (с изменениями или без них),
доведение до всеобщего сведения, а в некоторых странах -- и другие действия.
"Передача" произведения означает любой вид распространения, который позволяет
другим лицам создавать или получать копии произведения. Обычное взаимодействие
с пользователем через компьютерную сеть без создания копии передачей не
является.
Интерактивный интерфейс пользователя должен отображать "Информация об
авторском праве", достаточную для того, чтобы (1) обеспечить отображение
соответствующего уведомления об авторских правах и (2) сообщить пользователю
о том, что ему не предоставляются никакие гарантии на произведение (за
исключением явным образом предоставленных гарантий), о том, что лицензиаты
могут передавать произведение на условиях, описанных в настоящей Лицензии,
а также о том, как ознакомиться с текстом настоящей Лицензии. Если интерфейс
предоставляет собой список пользовательских команд или настроек, наподобие
меню, это требование считается выполненным при наличии явно выделенного
пункта в таком меню.
1. Исходный текст.
Под "Исходным текстом" понимается произведение в форме, которая более всего
подходит для внесения в него изменений. "Объектным кодом" называется
произведение в любой иной форме.
"Стандартный интерфейс" -- интерфейс, который либо является общепринятым
стандартом, введенным общепризнанным органом по стандартизации, либо, в случае
интерфейсов, характерных для конкретного языка программирования -- тот,
который широко используется разработчиками, пишущими программы на этом языке.
"Системные библиотеки" исполняемого произведения включают в себя то, что не
относится к произведению в целом и при этом (a) входит в обычный комплект
Основного компонента, но при этом не является его частью и (b) служит только
для обеспечения работы с этим Основным компонентом или для реализации
Стандартного интерфейса, для которого существует общедоступная реализация,
опубликованная в виде исходного текста. "Основным компонентом" в данном
контексте назван главный существенный компонент (ядро, оконная система и т.д.)
определенной операционной системы (если она используется), под управлением
которой функционирует исполняемое произведение, либо компилятор, используемый
для создания произведения или интерпретатор объектного кода, используемый для
его запуска.
"Полный исходный текст" для произведения в форме объектного кода -- весь
исходный текст, необходимый для создания, установки и (для исполняемого
произведения) функционирования объектного кода, а также модификации
произведения, включая сценарии, контролирующие эти действия. Однако он не
включает в себя Системные библиотеки, необходимые для функционирования
произведения, инструменты общего назначения или общедоступные свободные
программы, которые используются в неизменном виде для выполнения этих
действий, но не являются частью произведения. Полный исходный текст включает
в себя, например, файлы описания интерфейса, прилагаемые к файлам исходного
текста произведения, а также исходные тексты общих библиотек и динамически
связанных подпрограмм, которые требуются для функционирования произведения
и разработаны специально для этого, например, для прямой передачи данных
или управления потоками между этими подпрограммами и другими частями
произведения. Полный исходный текст не включает в себя то, что пользователи
могут сгенерировать автоматически из других частей Полного исходного текста.
Полным исходным текстом для произведения в форме исходных текстов является
само это произведение.
2. Основные права.
Все права, предоставленные на основании настоящей Лицензии, действуют в
течение срока действия авторских прав на Программу и не могут быть отозваны
при условии, что сформулированные в ней условия соблюдены. Настоящая Лицензия
однозначно подтверждает Ваши неограниченные права на запуск неизмененной
Программы. Настоящая Лицензия распространяется на результаты функционирования
Лицензионного произведения только в том случае, если они, учитывая их
содержание, сами являются частью Лицензионного произведения. Настоящая
Лицензия подтверждает Ваши права на свободное использование произведения
или другие аналогичные полномочия, предусмотренные действующим
законодательством об авторском праве.
Если Вы не осуществляете обычную передачу Лицензионного произведения, то
можете как угодно создавать, запускать и распространять его копии до тех пор,
пока ваша Лицензия сохраняет силу. Вы можете передавать Лицензионные
произведения третьим лицам исключительно для того, чтобы они внесли в них
изменения для Вас или предоставили Вам возможность их запуска, при условии,
что Вы соглашаетесь с условиями настоящей Лицензии при передаче всех
материалов, авторскими правами на которые Вы не обладаете. Лица, создающие
или запускающие Лицензионные произведения для Вас, должны делать это
исключительно от Вашего имени, под Вашим руководством и контролем, на
условиях, которые запрещают им создание без Вашей санкции каких-либо копий
материалов, на которые Вы обладаете авторским правом.
Любая другая передача разрешается исключительно при соблюдении описанных
ниже условий. Сублицензирование не допускается; раздел 10 делает его не нужным.
3. Защита прав пользователей от законов, запрещающих обход технических средств.
Ни одно Лицензионное произведение не должно считаться содержащим эффективные
технические средства, удовлетворяющие требованиям любого действующего закона,
принятого для исполнения обязательств, предусмотренных статьей 11 Договора ВОИС
по авторскому праву от 20 декабря 1996 года или аналогичных законов,
запрещающих или ограничивающих обход таких технических средств.
При передаче Лицензионного произведения Вы отказываетесь от всех
предоставляемых законом полномочий по запрету обхода технических средств,
используемых авторами в связи с осуществлением их прав, признавая, что такой
обход находится в рамках осуществления прав на использование Лицензионного
произведения, предоставленных настоящей Лицензией; также Вы отказываетесь
от любых попыток ограничить функционирование произведения или внесение в него
изменений, направленных на реализацию предоставленных Вам законом прав на
запрет пользователю обхода технических средств.
4. Передача неизмененных копий.
Вы можете передавать точные копии исходных текстов Программы в том виде,
в котором Вы их получили, на любом носителе, при условии, что Вы прилагаете
к каждой копии соответствующее уведомление об авторских правах способом,
обеспечивающим ознакомление с ним пользователя; сохраняете все уведомления
о том, что к тексту применима настоящая Лицензия и любые ограничения,
добавленные в соответствии с разделом 7; сохраняете все уведомления об
отсутствии каких-либо гарантий; предоставляете всем получателям вместе с
Программой копию настоящей Лицензии.
Вы можете установить любую цену за каждую копию, которую Вы передаете,
или распространять копии бесплатно; также Вы можете предложить поддержку
или гарантию за отдельную плату.
5. Передача измененных исходных текстов.
Вы можете передавать исходный текст произведения, основанного на Программе,
или изменений, необходимых для того, чтобы получить его из Программы, на
условиях, описанных в разделе 4, при соблюдении следующих условий:
а) Произведение должно содержать уведомления о произведенных Вами
изменениях с указанием их даты, сделанные способом, обеспечивающим
ознакомление с ними пользователя.
b) Произведение должно содержать уведомление о том, что оно
распространяется на условиях настоящей Лицензии, а также об условиях,
добавленных в соответствии с разделом 7, сделанное способом,
обеспечивающим ознакомление с ним пользователя. Данное требование имеет
приоритет над требованиями раздела 4 "оставлять нетронутыми все
уведомления".
c) Вы должны передать на условиях настоящей Лицензии всю работу целиком
любому лицу, которое приобретает копию. Таким образом, настоящая Лицензия
вместе с любыми применимыми условиями раздела 7 будет применяться к
произведению в целом и всем его частям, независимо от их комплектности.
Настоящая Лицензия не дает права на лицензирование произведения на любых
других условиях, но это не лишает законной силы такое разрешение, если Вы
получили его отдельно.
d) Если произведение имеет интерактивные пользовательские интерфейсы,
каждый из них должен отображать Информацию об авторском праве; однако,
если Программа имеет пользовательские интерфейсы, которые не отображают
информацию об авторском праве, от Вашего произведения этого также не
требуется.
Включение Лицензионного произведения в подборку на разделе хранения данных
или на носителе, на котором распространяется произведение, вместе с другими
отдельными самостоятельными произведениями, которые по своей природе не
являются переработкой Лицензионного произведения и не объединены с ним,
например, в программный комплекс, называется "набором", если авторские права
на подборку не используются для ограничения доступа к ней или законных прав
её пользователей сверх того, что предусматривают лицензии на отдельные
произведения. Включение Лицензионного произведения в набор не влечет применения
положений настоящей Лицензии к остальным его частям.
6. Передача произведения в формах, не относящихся к исходному тексту.
Вы можете передавать Лицензионное произведение в виде объектного кода в
соответствии с положениями разделов 4 и 5, при условии, что Вы также передаете
машиночитаемый Полный исходный текст в соответствии с условиями настоящей
Лицензии, одним из следующих способов:
а) Передавая объектный код или содержащий его материальный продукт (включая
распределенный материальный носитель), с приложением Полного исходного
текста наматериальном носителе, обычно используемом для обмена программным
обеспечением.
b) Передавая объектный код или содержащий его материальный продукт (включая
носитель, на котором распространяется произведение), с письменным
предложением, действительным в течение не менее трех лет либо до тех пор,
пока Вы предоставляете запасные части или поддержку для данного продукта,
о передаче любому обладателю объектного кода (1) копии Полного исходного
текста для всего программного обеспечения, содержащегося в продукте, на
которое распространяется действие настоящей Лицензии, на физическом
носителе, обычно используемом для обмена программным обеспечением, по цене,
не превышающей разумных затрат на передачу копии, или (2) доступа к Полному
исходному тексту с возможностью его копирования с сетевого сервера без
взимания платы.
с) Передавая отдельные копии объектного кода с письменной копией предложения
о предоставлении Полного исходного текста. Этот вариант допускается только
в отдельных случаях при распространении без извлечения прибыли, и только
если Вы получили объектный код с таким предложением в соответствии
с пунктом 6b.
d) Передавая объектный код посредством предоставления доступа к нему по
определенному адресу (бесплатно или за дополнительную плату), и предлагая
эквивалентный доступ к Полному исходному тексту таким же способом по тому же
адресу без какой-либо дополнительной оплаты. От Вас не требуется принуждать
получателей копировать Полный исходный текст вместе с объектным кодом. Если
объектный код размещен на сетевом сервере, Полный исходный текст может
находиться на другом сервере (управляемом Вами или третьим лицом), который
предоставляет аналогичную возможность копирования; при этом Вы должны четко
указать рядом с объектным кодом способ получения Полного исходного текста.
Независимо от того, на каком сервере расположен Полный исходный текст, Вы
обязаны убедиться в том, что он будет распространяться в течение времени,
необходимого для соблюдения этих требований.
e) Передавая объектный код с использованием одноранговой (пиринговой) сети,
при условии информирования других пользователей сети о том, где можно
бесплатно получить объектный код и Полный исходный текст произведения
способом, описанным в пункте 6d.
Не нужно включать в передаваемый объектный код его отделимые части, исходные
тексты которых не входят в состав Полного исходного текста, такие как Системные
библиотеки.
"Потребительский товар" это либо (1) "товар, предназначенный для личных нужд",
под которым понимается любое материальное личное имущество, которое обычно
используется для личных, семейных или домашних целей, или (2) что-либо
спроектированное или продающееся для использования в жилище. При определении
того, предназначен ли товар для личных нужд, сомнения должны толковаться в
пользу положительного ответа на этот вопрос. Применительно к конкретному
товару, используемому конкретным пользователем, под выражением "обычно
используется" имеется в виду способ, которым данный вид товаров преимущественно
или как правило используется, независимо от статуса конкретного пользователя
или способа, которым конкретный пользователь использует, предполагает или
будет использовать товар. Товар относится к предназначенным для личных нужд
независимо от того, насколько часто он используется в коммерческой
деятельности, промышленности или иной сфере, не относящейся к личным нуждам,
за исключением случая, когда использование в этой сфере представляет собой
единственный основной способ использования такого товара.
"Информация, необходимая для установки" Потребительского товара -- любые
методы, процедуры, сведения, необходимые для авторизации, или другая
информация, необходимая для установки и запуска в Потребительском товаре
измененных версий Лицензионного произведения, полученных при изменении
Полного исходного текста. Данная информация должна быть достаточной для
того, чтобы обеспечить возможность внесения в исходный текст изменений,
не приводящих к ограничению или нарушению его дальнейшей работоспособности.
Если вместе с Потребительским товаром или специально для использования
в нём Вы передаете произведение в виде объектного кода на условиях, описанных
в данном разделе, и такая передача является частью сделки, по которой право
владения и пользования Потребительским товаром переходит к получателю
пожизненно или на определенный срок (независимо от признаков сделки), Полный
исходный текст, передаваемый согласно данному разделу, должен сопровождаться
Информацией, необходимой для установки. Но это требование не применяется,
если ни Вы, ни какое-либо третье лицо не сохраняет за собой возможности
установки измененного объектного кода на Потребительский товар (например,
произведение было установлено в постоянную память).
Требование о предоставлении Информации, необходимой для установки, не
включает в себя требование продолжения оказания услуг по поддержке,
предоставления гарантии или обновлений для произведения, которое было изменено
или установлено получателем, либо для Потребительского товара, в котором оно
было изменено или на который оно было установлено. В доступе к сети может быть
отказано, если само внесение изменений существенно и негативно влияет на
работу сети, нарушает правила обмена данными или не поддерживает протоколы для
обмена данными по сети.
Передаваемый в соответствии с данным разделом Полный исходный текст и
предоставленная Информация, необходимая для установки, должны быть записаны в
формате, который имеет общедоступное описание (и общедоступную реализацию,
опубликованную в форме исходного текста) и не должны требовать никаких
специальных паролей или ключей для распаковки, чтения или копирования.
7. Дополнительные условия.
"Дополнительными разрешениями" называются условия, которые дополняют условия
настоящей Лицензии, делая исключения из одного или нескольких её положений.
Дополнительные разрешения, которые применимы ко всей Программе, должны
рассматриваться как часть настоящей Лицензии, в той степени, в которой они
соответствуют действующему законодательству. Если дополнительные разрешения
применяются только к части Программы, эта часть может быть использована отдельно
на измененных условиях, но вся Программа продолжает использоваться на условиях
настоящей Лицензии без учета дополнительных разрешений.
Когда Вы передаете копию Лицензионного произведения, Вы можете по своему
усмотрению исключить любые дополнительные разрешения, примененные к этой копии
или к любой её части. (Для дополнительных разрешений может быть заявлено
требование об их удалении в определенных случаях, когда Вы вносите изменения в
произведение.) Вы можете добавлять дополнительные разрешения к добавленным Вами
в Лицензионное произведение материалам, на которые Вы обладаете авторскими
правами или правом выдачи соответствующего разрешения.
Независимо от любых других положений настоящей Лицензии, Вы можете дополнить
следующими условиями положения настоящей Лицензии в отношении материала,
добавленного к Лицензионному произведению (если это разрешено обладателями
авторских прав на материал):
a) отказом от гарантий или ограничением ответственности, отличающимися от
тех, что описаны в разделах 15 и 16 настоящей Лицензии; либо
b) требованием сохранения соответствующей информации о правах или об
авторстве материала, или включения её в Информацию об авторском праве,
отображаемую содержащим его произведением; либо
c) запретом на искажение информации об источнике происхождения материала
или требованием того, чтобы измененные версии такого материала содержали
корректную отметку об отличиях от исходной версии; либо
d) ограничением использования в целях рекламы имен лицензиаров или авторов
материала; либо
e) отказом от предоставления прав на использование в качестве товарных
знаков некоторых торговых наименований, товарных знаков или знаков
обслуживания; либо
f) требованием от каждого, кто по договору передает материал (или его
измененные версии), предоставления компенсации лицензиарам и авторам
материала в виде принятия на себя любой ответственности, которую этот
договор налагает на лицензиаров и авторов.
Все остальные ограничительные дополнительные условия считаются "дополнительными
запретами" по смыслу раздела 10. Если программа, которую Вы получили, или любая
её часть содержит уведомление о том, что наряду с настоящей Лицензией её
использование регулируется условием, относящимся к дополнительным запретам, Вы
можете удалить такое условие. Если лицензия содержит дополнительный запрет, но
допускает лицензирование на измененных условиях или передачу в соответствии с
настоящей Лицензией, Вы можете добавить к Лицензионному произведению материал,
используемый на условиях такой лицензии, в том случае, если дополнительный
запрет не сохраняется при таком изменении условий лицензии или передаче.
Если Вы добавляете условия для использования Лицензионного произведения в
соответствии с настоящим разделом, Вы должны поместить в соответствующих файлах
исходного текста уведомление о том, что к этим файлам применяются дополнительные
условия, или указание на то, как ознакомиться с соответствующими условиями.
Дополнительные разрешающие или ограничивающие условия могут быть сформулированы
в виде отдельной лицензии или зафиксированы как исключения; вышеуказанные
требования применяются в любом случае.
8. Прекращение действия.
Вы не можете распространять Лицензионное произведение или вносить в него
изменения на условиях, отличающихся от явно оговоренных в настоящей Лицензии.
Любая попытка распространения или внесения изменений на иных условиях является
ничтожной и автоматически прекращает Ваши права, полученные по настоящей
Лицензии (включая лицензию на любые патенты, предоставленные согласно третьему
пункту раздела 11).
Тем не менее если Вы прекращаете нарушение настоящей Лицензии, Ваши права,
полученные от конкретного правообладателя, восстанавливаются (а) временно, до
тех пор пока правообладатель явно и окончательно не прекратит действие Ваших
прав, и (б) навсегда, если правообладатель не уведомит Вас о нарушении с помощью
надлежащих средств в течение 60 дней после прекращения нарушений.
Кроме того, Ваши права, полученные от конкретного правообладателя,
восстанавливаются навсегда, если правообладатель впервые любым подходящим
способом уведомляет Вас о нарушении настоящей Лицензии на свое произведение (для
любого произведения) и Вы устраняете нарушение в течение 30 дней после получения
уведомления.
Прекращение Ваших прав, описанное в настоящем разделе, не прекращает действие
лицензий лиц, которые получили от Вас копии произведения или права,
предоставляемые настоящей Лицензией. Если Ваши права были прекращены навсегда и
не восстановлены, Вы не можете вновь получить право на тот же материал на
условиях, описанных в разделе 10.
9. Акцепт не требуется для получения копий.
Вы не обязаны принимать условия настоящей Лицензии для того, чтобы получить или
запустить копию Программы. Случайное распространение Лицензионного произведения,
происходящее вследствие использования одноранговой (пиринговой) сети для
получения его копии, также не требует принятия этих условий. Тем не менее только
настоящая Лицензия дает Вам право распространять или изменять любое Лицензионное
произведение. Если Вы не приняли условия настоящей Лицензии, такие действия
будут нарушением авторского права. Поэтому изменяя или распространяя
Лицензионное произведение, Вы выражаете согласие с условиями настоящей Лицензии.
10. Автоматическое получение прав последующими получателями.
Каждый раз, когда Вы передаете Лицензионное произведение, получатель
автоматически получает от его лицензиара право запускать, изменять и
распространять это произведение при условии соблюдения настоящей Лицензии. Вы не
несете ответственности за соблюдение третьими лицами условий настоящей Лицензии.
"Реорганизацией" называются действия, в результате которых передается управление
организацией или значительная часть её активов, а также происходит разделение
или слияние организаций. Если распространение Лицензионного произведения
является результатом реорганизации, каждая из сторон сделки, получающая копию
произведения, также получает все права на произведение, которые предшествующее
юридическое лицо имело или могло предоставить согласно предыдущему абзацу, а
также право на владение Полным исходным текстом произведения от предшественника,
осуществляемое в его интересах, если предшественник владеет им или может
получить его при разумных усилиях.
Вы не можете налагать каких-либо дополнительных ограничений на осуществление
прав, предоставленных или подтвержденных в соответствии с настоящей Лицензией.
Например, Вы не можете ставить осуществление прав, предоставленных по настоящей
Лицензии, в зависимость от оплаты отчислений, роялти или других сборов; также Вы
не можете инициировать судебный процесс (включая встречный иск или заявление
встречного требования в судебном процессе) о нарушении любых патентных прав при
создании, использовании, продаже, предложении продажи, импорте Программы или
любой её части.
11. Патенты.
"Инвестором" называется правообладатель, разрешающий использование Программы
либо произведения, на котором основана Программа, на условиях настоящей
Лицензии. Произведение, лицензированное таким образом, называется "версией со
вкладом" инвестора.
"Неотъемлемые патентные претензии" инвестора -- все патентные права,
принадлежащие инвестору или контролируемые им в настоящее время либо
приобретенные в будущем, которые могут быть нарушены созданием, использованием
или продажей версии со вкладом, допускаемыми настоящей Лицензией; они не
включают в себя права, которые будут нарушены исключительно вследствие будущих
изменений версии со вкладом. Для целей данного определения под "контролем"
понимается право выдавать патентные сублицензии способами, не нарушающими
требований настоящей Лицензии.
Каждый инвестор предоставляет Вам неисключительную безвозмездную лицензию на
патент, действующую во всем мире, соответствующую неотъемлемым патентным
претензиям инвестора, на создание, использование, продажу, предложение для
продажи, импорт, а также запуск, внесение изменений и распространение всего, что
входит в состав версии со вкладом.
В следующих трех абзацах "лицензией на патент" называется любое явно выраженное
вовне согласие или обязательство не применять патент (например, выдача
разрешения на использование запатентованного объекта или обещание не подавать в
суд за нарушение патента). "Выдать" кому-то такую лицензию на патент означает
заключить такое соглашение или обязаться не применять патент против него.
Если Вы передаете Лицензионное произведение, сознательно основываясь на лицензии
на патент, в то время как Полный исходный текст произведения невозможно
бесплатно скопировать с общедоступного сервера или другим не вызывающим
затруднений способом, Вы должны либо (1) обеспечить возможность такого доступа к
Полному исходному тексту, либо (2) отказаться от прав, предоставленных по
лицензии на патент для данного произведения, либо (3) принять меры по передаче
лицензии на патент последующим получателям произведения, в соответствии с
требованиями настоящей Лицензии. "Сознательно основываясь" означает, что Вы
знаете, что при отсутствии лицензии на патент передача Вами Лицензионного
произведения в определенной стране или использование получателем переданного ему
Вами Лицензионного произведения в этой стране нарушит один или несколько
определенных патентов этой страны, срок действия которых не истек.
Если в соответствии или в связи с единичной сделкой либо соглашением Вы
передаете или делаете заказ на распространение Лицензионного произведения, и
предоставляете определенным лицам, получающим Лицензионное произведение,
лицензию на патент, разрешающую им использовать, распространять, вносить
изменения или передавать конкретные экземпляры Лицензионного произведения,
права, которые Вы предоставляете по лицензии на патент, автоматически переходят
ко всем получателям Лицензионного произведения и произведений, созданных на его
основе.
Патентная лицензия называется "дискриминирующей", если она не покрывает,
запрещает осуществление или содержит в качестве условия отказ от применения
одного или нескольких прав, предоставленных настоящей Лицензией. Вы не можете
передавать Лицензионное произведение, если Вы являетесь участником договора с
третьим лицом, осуществляющим распространение программного обеспечения, в
соответствии с которым Вы делаете в пользу третьего лица выплаты, размер которых
зависит от масштабов Вашей деятельности по передаче произведения, и в
соответствии с которым любое третье лицо, получающее от Вас Лицензионное
произведение, делает это на условиях дискриминирующей патентной лицензии (а)
которая зависит от количества копий Лицензионного произведения, переданных Вами
(или копий, сделанных с этих копий), или (b) которая используется
преимущественно в конкретных товарах или подборках, содержащих Лицензионное
произведение, или в связи с ними, в том случае, если Вы заключили данный договор
или получили лицензию на патент после 28 марта 2007 года.
Ничто в настоящей Лицензии не должно толковаться как исключение или ограничение
любого предполагаемого права или других способов противодействия нарушениям,
которые во всем остальном могут быть доступны для Вас в соответствии с
применимым патентным правом.
12. Запрет отказывать в свободе другим.
Если на Вас наложены обязанности (будь то по решению суда, договору или иным
способом), которые противоречат условиям настоящей Лицензии, это не освобождает
Вас от соблюдения её условий. Если Вы не можете передать Лицензионное
произведение так, чтобы одновременно выполнять Ваши обязательства по настоящей
Лицензии и любые другие относящиеся к делу обязательства, то Вы не можете
передавать его вообще. Например, если Вы согласны с условием, обязывающими Вас
производить сбор отчислений за дальнейшую передачу от тех, кому Вы передаете
Программу, то для того, чтобы соблюсти это условие и выполнить требования
настоящей Лицензии, Вы должны полностью воздержаться от передачи Программы.
13. Удаленное сетевое взаимодействие.
Под "Прокси-программой" понимается отдельная программа, специально
разработанная для использования совместно с Лицензионным произведением,
и взаимодействующая с ним прямо или косвенно через любой вид программного
интерфейса, компьютерную сеть, имитацию такой сети, или, в свою очередь,
через другую Прокси-программу.
Независимо от любых других положений настоящей Лицензии, если вы
предоставляете любому пользователю возможность взаимодействовать с Лицензионным
произведением через компьютерную сеть, имитацию такой сети, или через любое
количество "Прокси-программ", вы должны в явной форме предложить этому
пользователю возможность получить Полный исходный текст Лицензионного
произведения и всех Прокси-программ путём предоставления доступа к нему
с сетевого сервера без взимания платы, посредством стандартных или
традиционных способов, используемых для копирования программного обеспечения.
Полный исходный текст Лицензионного произведения должен предоставляться
пользователю на условиях настоящей Лицензии, а Полный исходный текст
Прокси-программ должен предоставляться пользователю либо на условиях настоящей
Лицензии, либо на условиях одной из свободных лицензий, совместимых с
Генеральной публичной Лицензией GNU, перечисленных Фондом Свободного
Программного Обеспечения в списке под названием "Лицензии свободных программ,
совместимые с GPL".
14. Пересмотренные редакции настоящей Лицензии.
Автор настоящей Лицензии время от времени может публиковать пересмотренные
и (или) новые редакции Сетевой Публичной Лицензии Vitastor. Они будут аналогичны
по смыслу настоящей редакции, но могут отличаться от нее в деталях, направленных
на решение новых проблем или регулирование новых отношений.
Каждой редакции присваивается собственный номер. Если для Программы указано,
что к ней применима определенная редакция Сетевой Публичной Лицензии Vitastor
"или любая более поздняя редакция", у Вас есть возможность использовать термины
и условия, содержащиеся в редакции с указанным номером или любой более поздней
редакции, опубликованной автором настоящей Лицензии. Если для Программы не
указан номер редакции Сетевой Публичной Лицензии Vitastor, Вы можете выбрать
любую редакцию, опубликованную автором настоящей Лицензии.
Более поздние редакции Лицензии могут дать Вам дополнительные или принципиально
иные права. Тем не менее в результате Вашего выбора более поздней редакции на
автора или правообладателя не возлагается никаких дополнительных обязанностей.
15. Отказ от гарантий.
НА ПРОГРАММУ НЕ ПРЕДОСТАВЛЯЕТСЯ НИКАКИХ ГАРАНТИЙ ЗА ИСКЛЮЧЕНИЕМ ПРЕДУСМОТРЕННЫХ
ДЕЙСТВУЮЩИМ ЗАКОНОДАТЕЛЬСТВОМ. ЕСЛИ ИНОЕ НЕ УКАЗАНО В ПИСЬМЕННОЙ ФОРМЕ,
ПРАВООБЛАДАТЕЛИ И (ИЛИ) ТРЕТЬИ ЛИЦА ПРЕДОСТАВЛЯЮТ ПРОГРАММУ "КАК ЕСТЬ", БЕЗ
КАКИХ-ЛИБО ЯВНЫХ ИЛИ ПОДРАЗУМЕВАЕМЫХ ГАРАНТИЙ, ВКЛЮЧАЯ ГАРАНТИИ ПРИГОДНОСТИ ДЛЯ
КОНКРЕТНЫХ ЦЕЛЕЙ, НО НЕ ОГРАНИЧИВАЯСЬ ИМИ. ВЕСЬ РИСК, СВЯЗАННЫЙ С КАЧЕСТВОМ И
ПРОИЗВОДИТЕЛЬНОСТЬЮ ПРОГРАММЫ, ВОЗЛАГАЕТСЯ НА ВАС. ЕСЛИ В ПРОГРАММЕ БУДУТ
ВЫЯВЛЕНЫ НЕДОСТАТКИ, ВЫ ПРИНИМАЕТЕ НА СЕБЯ СТОИМОСТЬ ВСЕГО НЕОБХОДИМОГО
ОБСЛУЖИВАНИЯ, РЕМОНТА ИЛИ ИСПРАВЛЕНИЯ.
16. Ограничение ответственности.
ЕСЛИ ИНОЕ НЕ ПРЕДУСМОТРЕНО ДЕЙСТВУЮЩИМ ЗАКОНОДАТЕЛЬСТВОМ ИЛИ СОГЛАШЕНИЕМ СТОРОН,
ЗАКЛЮЧЕННЫМ В ПИСЬМЕННОЙ ФОРМЕ, ПРАВООБЛАДАТЕЛЬ ИЛИ ИНОЕ ЛИЦО, КОТОРОЕ ВНОСИТ
ИЗМЕНЕНИЯ В ПРОГРАММУ И (ИЛИ) ПЕРЕДАЕТ ЕЁ НА УСЛОВИЯХ, СФОРМУЛИРОВАННЫХ ВЫШЕ, НЕ
МОЖЕТ НЕСТИ ОТВЕТСТВЕННОСТЬ ПЕРЕД ВАМИ ЗА ПРИЧИНЕННЫЙ УЩЕРБ, ВКЛЮЧАЯ УЩЕРБ
ОБЩЕГО ЛИБО КОНКРЕТНОГО ХАРАКТЕРА, ПРИЧИНЕННЫЙ СЛУЧАЙНО ИЛИ ЯВЛЯЮЩИЙСЯ
СЛЕДСТВИЕМ ИСПОЛЬЗОВАНИЯ ПРОГРАММЫ ЛИБО НЕВОЗМОЖНОСТИ ЕЁ ИСПОЛЬЗОВАНИЯ (В ТОМ
ЧИСЛЕ ЗА УНИЧТОЖЕНИЕ ИЛИ МОДИФИКАЦИЮ ИНФОРМАЦИИ, ЛИБО УБЫТКИ, ПОНЕСЕННЫЕ ВАМИ
ИЛИ ТРЕТЬИМИ ЛИЦАМИ, ЛИБО СБОИ ПРОГРАММЫ ПРИ ВЗАИМОДЕЙСТВИИ С ДРУГИМ ПРОГРАММНЫМ
ОБЕСПЕЧЕНИЕМ), В ТОМ ЧИСЛЕ И В СЛУЧАЯХ, КОГДА ПРАВООБЛАДАТЕЛЬ ИЛИ ТРЕТЬЕ ЛИЦО
ПРЕДУПРЕЖДЕНЫ О ВОЗМОЖНОСТИ ПРИЧИНЕНИЯ ТАКИХ УБЫТКОВ.
17. Толкование разделов 15 и 16.
Если отказ от гарантии и ограничение ответственности, представленные выше, по
закону не могут быть применены в соответствии с их условиями, суды,
рассматривающие спор, должны применить действующий закон, который в наибольшей
степени предусматривает абсолютный отказ от всей гражданской ответственности в
связи с Программой, за исключением случаев, когда гарантия или принятие на себя
ответственности за копию программы предоставляется за плату.
КОНЕЦ ОПРЕДЕЛЕНИЙ И УСЛОВИЙ
Порядок применения условий Лицензии к Вашим программам
Если Вы разрабатываете новую программу и хотите, чтобы её использование принесло
максимальную пользу обществу, наилучший способ достичь этого -- сделать её
свободной, чтобы все могли распространять и изменять её на условиях настоящей
Лицензии.
Для этого сделайте так, чтобы программа содержала в себе описанные ниже
уведомления. Самым надежным способом это сделать является включение их в начало
каждого файла исходного текста, чтобы наиболее эффективным образом сообщить об
отсутствии гарантий; каждый файл должен иметь по меньшей мере одну строку с
оповещением об авторских правах и указанием на то, где находится полный текст
уведомлений.
<Строка с названием Программы и информацией о её назначении.>
Copyright © <год выпуска программы в свет> <имя автора>
Эта программа является свободным программным обеспечением: Вы можете
распространять её и (или) изменять, соблюдая условия Сетевой Публичной
Лицензии Vitastor, опубликованной автором Vitastor, либо редакции 1.1
Лицензии, либо (на Ваше усмотрение) любой редакции, выпущенной позже.
Эта программа распространяется в расчете на то, что она окажется полезной,
но БЕЗ КАКИХ-ЛИБО ГАРАНТИЙ, включая подразумеваемую гарантию КАЧЕСТВА либо
ПРИГОДНОСТИ ДЛЯ ОПРЕДЕЛЕННЫХ ЦЕЛЕЙ. Ознакомьтесь с Сетевой Публичной
Лицензией Vitastor для получения более подробной информации.
Также добавьте информацию о том, как связаться с Вами посредством электронной
или обычной почты.
Если ваша программа взаимодействует с пользователями удаленно через
компьютерную сеть, Вы также должны убедиться, что обеспечили её пользователям
возможность получить её исходные тексты. Например, если Ваша программа является
веб-приложением, её интерфейс может отображать ссылку "Исходные коды", которая
указывает на архив с текстом. Существует много способов, которыми Вы можете
распространять исходные тексты, для разных программ подходят разные решения;
ознакомьтесь с разделом 13 для того, чтобы узнать конкретные требования.

View File

@ -61,7 +61,7 @@ modification follow.
0. Definitions. 0. Definitions.
"This License" refers to version 1 of the Vitastor Network Public License. "This License" refers to version 1.1 of the Vitastor Network Public License.
"Copyright" also means copyright-like laws that apply to other kinds of "Copyright" also means copyright-like laws that apply to other kinds of
works, such as semiconductor masks. works, such as semiconductor masks.
@ -629,7 +629,7 @@ the "copyright" line and a pointer to where the full notice is found.
This program is free software: you can redistribute it and/or modify This program is free software: you can redistribute it and/or modify
it under the terms of the Vitastor Network Public License as published by it under the terms of the Vitastor Network Public License as published by
the Vitastor Author, either version 1 of the License, or the Vitastor Author, either version 1.1 of the License, or
(at your option) any later version. (at your option) any later version.
This program is distributed in the hope that it will be useful, This program is distributed in the hope that it will be useful,

View File

@ -1,6 +1,6 @@
#!/bin/bash #!/bin/bash
gcc -I. -E -o fio_headers.i src/fio_headers.h gcc -I. -E -o fio_headers.i src/util/fio_headers.h
rm -rf fio-copy rm -rf fio-copy
for i in `grep -Po 'fio/[^"]+' fio_headers.i | sort | uniq`; do for i in `grep -Po 'fio/[^"]+' fio_headers.i | sort | uniq`; do

View File

@ -5,7 +5,7 @@
#cd b/qemu; make qapi #cd b/qemu; make qapi
gcc -I qemu/b/qemu `pkg-config glib-2.0 --cflags` \ gcc -I qemu/b/qemu `pkg-config glib-2.0 --cflags` \
-I qemu/include -E -o qemu_driver.i src/qemu_driver.c -I qemu/include -E -o qemu_driver.i src/client/qemu_driver.c
rm -rf qemu-copy rm -rf qemu-copy
for i in `grep -Po 'qemu/[^"]+' qemu_driver.i | sort | uniq`; do for i in `grep -Po 'qemu/[^"]+' qemu_driver.i | sort | uniq`; do

@ -1 +1 @@
Subproject commit 5dc108754ad40d3b1d024f9bd7cca0595ef1a1db Subproject commit 8de8b467acbca50cfd8835c20e0e379110f3b32b

View File

@ -1,3 +1,2 @@
vitastor-csi vitastor-csi
go.sum
Dockerfile Dockerfile

View File

@ -1,14 +1,15 @@
# Compile stage # Compile stage
FROM golang:buster AS build FROM golang:bookworm AS build
ADD go.mod /app/ ADD go.sum go.mod /app/
RUN cd /app; CGO_ENABLED=1 GOOS=linux GOARCH=amd64 go mod download -x RUN cd /app; CGO_ENABLED=1 GOOS=linux GOARCH=amd64 go mod download -x
ADD . /app ADD . /app
RUN perl -i -e '$/ = undef; while(<>) { s/\n\s*(\{\s*\n)/$1\n/g; s/\}(\s*\n\s*)else\b/$1} else/g; print; }' `find /app -name '*.go'` RUN perl -i -e '$/ = undef; while(<>) { s/\n\s*(\{\s*\n)/$1\n/g; s/\}(\s*\n\s*)else\b/$1} else/g; print; }' `find /app -name '*.go'` && \
RUN cd /app; CGO_ENABLED=1 GOOS=linux GOARCH=amd64 go build -o vitastor-csi cd /app && \
CGO_ENABLED=1 GOOS=linux GOARCH=amd64 go build -o vitastor-csi
# Final stage # Final stage
FROM debian:buster FROM debian:bookworm
LABEL maintainers="Vitaliy Filippov <vitalif@yourcmc.ru>" LABEL maintainers="Vitaliy Filippov <vitalif@yourcmc.ru>"
LABEL description="Vitastor CSI Driver" LABEL description="Vitastor CSI Driver"
@ -18,15 +19,30 @@ ENV CSI_ENDPOINT=""
RUN apt-get update && \ RUN apt-get update && \
apt-get install -y wget && \ apt-get install -y wget && \
wget -q -O /etc/apt/trusted.gpg.d/vitastor.gpg https://vitastor.io/debian/pubkey.gpg && \
(echo deb http://vitastor.io/debian buster main > /etc/apt/sources.list.d/vitastor.list) && \
(echo deb http://deb.debian.org/debian buster-backports main > /etc/apt/sources.list.d/backports.list) && \
(echo "APT::Install-Recommends false;" > /etc/apt/apt.conf) && \ (echo "APT::Install-Recommends false;" > /etc/apt/apt.conf) && \
apt-get update && \ apt-get update && \
apt-get install -y e2fsprogs xfsprogs vitastor kmod && \ apt-get install -y e2fsprogs xfsprogs kmod iproute2 \
# dependencies of qemu-storage-daemon
libnuma1 liburing2 libglib2.0-0 libfuse3-3 libaio1 libzstd1 libnettle8 \
libgmp10 libhogweed6 libp11-kit0 libidn2-0 libunistring2 libtasn1-6 libpcre2-8-0 libffi8 && \
apt-get clean && \ apt-get clean && \
(echo options nbd nbds_max=128 > /etc/modprobe.d/nbd.conf) (echo options nbd nbds_max=128 > /etc/modprobe.d/nbd.conf)
COPY --from=build /app/vitastor-csi /bin/ COPY --from=build /app/vitastor-csi /bin/
RUN (echo deb http://vitastor.io/debian bookworm main > /etc/apt/sources.list.d/vitastor.list) && \
((echo 'Package: *'; echo 'Pin: origin "vitastor.io"'; echo 'Pin-Priority: 1000') > /etc/apt/preferences.d/vitastor.pref) && \
wget -q -O /etc/apt/trusted.gpg.d/vitastor.gpg https://vitastor.io/debian/pubkey.gpg && \
apt-get update && \
apt-get install -y vitastor-client && \
wget https://vitastor.io/archive/qemu/qemu-bookworm-8.1.2%2Bds-1%2Bvitastor1/qemu-utils_8.1.2%2Bds-1%2Bvitastor1_amd64.deb && \
wget https://vitastor.io/archive/qemu/qemu-bookworm-8.1.2%2Bds-1%2Bvitastor1/qemu-block-extra_8.1.2%2Bds-1%2Bvitastor1_amd64.deb && \
dpkg -x qemu-utils*.deb tmp1 && \
dpkg -x qemu-block-extra*.deb tmp1 && \
cp -a tmp1/usr/bin/qemu-storage-daemon /usr/bin/ && \
mkdir -p /usr/lib/x86_64-linux-gnu/qemu && \
cp -a tmp1/usr/lib/x86_64-linux-gnu/qemu/block-vitastor.so /usr/lib/x86_64-linux-gnu/qemu/ && \
rm -rf tmp1 *.deb && \
apt-get clean
ENTRYPOINT ["/bin/vitastor-csi"] ENTRYPOINT ["/bin/vitastor-csi"]

View File

@ -1,4 +1,4 @@
VERSION ?= v0.6.4 VERSION ?= v1.6.1
all: build push all: build push

View File

@ -2,6 +2,7 @@
apiVersion: v1 apiVersion: v1
kind: ConfigMap kind: ConfigMap
data: data:
# You can add multiple configuration files here to use a multi-cluster setup
vitastor.conf: |- vitastor.conf: |-
{"etcd_address":"http://192.168.7.2:2379","etcd_prefix":"/vitastor"} {"etcd_address":"http://192.168.7.2:2379","etcd_prefix":"/vitastor"}
metadata: metadata:

View File

@ -49,7 +49,7 @@ spec:
capabilities: capabilities:
add: ["SYS_ADMIN"] add: ["SYS_ADMIN"]
allowPrivilegeEscalation: true allowPrivilegeEscalation: true
image: vitalif/vitastor-csi:v0.6.4 image: vitalif/vitastor-csi:v1.6.1
args: args:
- "--node=$(NODE_ID)" - "--node=$(NODE_ID)"
- "--endpoint=$(CSI_ENDPOINT)" - "--endpoint=$(CSI_ENDPOINT)"
@ -82,6 +82,8 @@ spec:
name: host-sys name: host-sys
- mountPath: /run/mount - mountPath: /run/mount
name: host-mount name: host-mount
- mountPath: /run/vitastor-csi
name: run-vitastor-csi
- mountPath: /lib/modules - mountPath: /lib/modules
name: lib-modules name: lib-modules
readOnly: true readOnly: true
@ -102,7 +104,7 @@ spec:
- "--health-port=9898" - "--health-port=9898"
env: env:
- name: CSI_ENDPOINT - name: CSI_ENDPOINT
value: unix://csi/csi.sock value: unix:///csi/csi.sock
volumeMounts: volumeMounts:
- mountPath: /csi - mountPath: /csi
name: socket-dir name: socket-dir
@ -132,6 +134,9 @@ spec:
- name: host-mount - name: host-mount
hostPath: hostPath:
path: /run/mount path: /run/mount
- name: run-vitastor-csi
hostPath:
path: /run/vitastor-csi
- name: lib-modules - name: lib-modules
hostPath: hostPath:
path: /lib/modules path: /lib/modules

View File

@ -35,10 +35,13 @@ rules:
verbs: ["get", "list", "watch"] verbs: ["get", "list", "watch"]
- apiGroups: ["snapshot.storage.k8s.io"] - apiGroups: ["snapshot.storage.k8s.io"]
resources: ["volumesnapshots"] resources: ["volumesnapshots"]
verbs: ["get", "list"] verbs: ["get", "list", "patch"]
- apiGroups: ["snapshot.storage.k8s.io"]
resources: ["volumesnapshots/status"]
verbs: ["get", "list", "patch"]
- apiGroups: ["snapshot.storage.k8s.io"] - apiGroups: ["snapshot.storage.k8s.io"]
resources: ["volumesnapshotcontents"] resources: ["volumesnapshotcontents"]
verbs: ["create", "get", "list", "watch", "update", "delete"] verbs: ["create", "get", "list", "watch", "update", "delete", "patch"]
- apiGroups: ["snapshot.storage.k8s.io"] - apiGroups: ["snapshot.storage.k8s.io"]
resources: ["volumesnapshotclasses"] resources: ["volumesnapshotclasses"]
verbs: ["get", "list", "watch"] verbs: ["get", "list", "watch"]
@ -53,7 +56,7 @@ rules:
verbs: ["get", "list", "watch"] verbs: ["get", "list", "watch"]
- apiGroups: ["snapshot.storage.k8s.io"] - apiGroups: ["snapshot.storage.k8s.io"]
resources: ["volumesnapshotcontents/status"] resources: ["volumesnapshotcontents/status"]
verbs: ["update"] verbs: ["update", "patch"]
- apiGroups: [""] - apiGroups: [""]
resources: ["configmaps"] resources: ["configmaps"]
verbs: ["get"] verbs: ["get"]

View File

@ -23,6 +23,11 @@ metadata:
name: csi-vitastor-provisioner name: csi-vitastor-provisioner
spec: spec:
replicas: 3 replicas: 3
strategy:
type: RollingUpdate
rollingUpdate:
maxUnavailable: 1
maxSurge: 0
selector: selector:
matchLabels: matchLabels:
app: csi-vitastor-provisioner app: csi-vitastor-provisioner
@ -46,7 +51,7 @@ spec:
priorityClassName: system-cluster-critical priorityClassName: system-cluster-critical
containers: containers:
- name: csi-provisioner - name: csi-provisioner
image: k8s.gcr.io/sig-storage/csi-provisioner:v2.2.0 image: k8s.gcr.io/sig-storage/csi-provisioner:v3.0.0
args: args:
- "--csi-address=$(ADDRESS)" - "--csi-address=$(ADDRESS)"
- "--v=5" - "--v=5"
@ -116,7 +121,7 @@ spec:
privileged: true privileged: true
capabilities: capabilities:
add: ["SYS_ADMIN"] add: ["SYS_ADMIN"]
image: vitalif/vitastor-csi:v0.6.4 image: vitalif/vitastor-csi:v1.6.1
args: args:
- "--node=$(NODE_ID)" - "--node=$(NODE_ID)"
- "--endpoint=$(CSI_ENDPOINT)" - "--endpoint=$(CSI_ENDPOINT)"

View File

@ -12,8 +12,6 @@ parameters:
etcdVolumePrefix: "" etcdVolumePrefix: ""
poolId: "1" poolId: "1"
# you can choose other configuration file if you have it in the config map # you can choose other configuration file if you have it in the config map
# different etcd URLs and prefixes should also be put in the config
#configPath: "/etc/vitastor/vitastor.conf" #configPath: "/etc/vitastor/vitastor.conf"
# you can also specify etcdUrl here, maybe to connect to another Vitastor cluster allowVolumeExpansion: true
# multiple etcdUrls may be specified, delimited by comma
#etcdUrl: "http://192.168.7.2:2379"
#etcdPrefix: "/vitastor"

View File

@ -0,0 +1,13 @@
---
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: test-vitastor-pvc-block
spec:
storageClassName: vitastor
volumeMode: Block
accessModes:
- ReadWriteMany
resources:
requests:
storage: 10Gi

View File

@ -0,0 +1,7 @@
apiVersion: snapshot.storage.k8s.io/v1
kind: VolumeSnapshotClass
metadata:
name: vitastor-snapclass
driver: csi.vitastor.io
deletionPolicy: Delete
parameters:

View File

@ -0,0 +1,16 @@
---
apiVersion: v1
kind: PersistentVolumeClaim
metadata:
name: test-vitastor-clone
spec:
storageClassName: vitastor
dataSource:
name: snap1
kind: VolumeSnapshot
apiGroup: snapshot.storage.k8s.io
accessModes:
- ReadWriteOnce
resources:
requests:
storage: 10Gi

View File

@ -0,0 +1,8 @@
apiVersion: snapshot.storage.k8s.io/v1
kind: VolumeSnapshot
metadata:
name: snap1
spec:
volumeSnapshotClassName: vitastor-snapclass
source:
persistentVolumeClaimName: test-vitastor-pvc

View File

@ -0,0 +1,17 @@
apiVersion: v1
kind: Pod
metadata:
name: vitastor-test-block-pvc
namespace: default
spec:
containers:
- name: vitastor-test-block-pvc
image: nginx
volumeDevices:
- name: data
devicePath: /dev/xvda
volumes:
- name: data
persistentVolumeClaim:
claimName: test-vitastor-pvc-block
readOnly: false

View File

@ -0,0 +1,17 @@
apiVersion: v1
kind: Pod
metadata:
name: vitastor-test-nginx
namespace: default
spec:
containers:
- name: vitastor-test-nginx
image: nginx
volumeMounts:
- mountPath: /usr/share/nginx/html/s3
name: data
volumes:
- name: data
persistentVolumeClaim:
claimName: test-vitastor-pvc
readOnly: false

View File

@ -4,26 +4,12 @@ go 1.15
require ( require (
github.com/container-storage-interface/spec v1.4.0 github.com/container-storage-interface/spec v1.4.0
github.com/coreos/bbolt v0.0.0-00010101000000-000000000000 // indirect
github.com/coreos/etcd v3.3.25+incompatible // indirect
github.com/coreos/go-semver v0.3.0 // indirect
github.com/coreos/go-systemd v0.0.0-20191104093116-d3cd4ed1dbcf // indirect
github.com/coreos/pkg v0.0.0-20180928190104-399ea9e2e55f // indirect
github.com/dustin/go-humanize v1.0.0 // indirect
github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b
github.com/gorilla/websocket v1.4.2 // indirect
github.com/grpc-ecosystem/go-grpc-middleware v1.3.0 // indirect
github.com/grpc-ecosystem/go-grpc-prometheus v1.2.0 // indirect
github.com/grpc-ecosystem/grpc-gateway v1.16.0 // indirect
github.com/jonboulle/clockwork v0.2.2 // indirect
github.com/kubernetes-csi/csi-lib-utils v0.9.1 github.com/kubernetes-csi/csi-lib-utils v0.9.1
github.com/soheilhy/cmux v0.1.5 // indirect
github.com/tmc/grpc-websocket-proxy v0.0.0-20201229170055-e5319fda7802 // indirect
github.com/xiang90/probing v0.0.0-20190116061207-43a291ad63a2 // indirect
go.etcd.io/bbolt v0.0.0-00010101000000-000000000000 // indirect
go.etcd.io/etcd v3.3.25+incompatible
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb
golang.org/x/xerrors v0.0.0-20200804184101-5ec99f83aff1 // indirect
google.golang.org/grpc v1.33.1 google.golang.org/grpc v1.33.1
google.golang.org/protobuf v1.24.0
k8s.io/klog v1.0.0 k8s.io/klog v1.0.0
k8s.io/utils v0.0.0-20210305010621-2afb4311ab10 k8s.io/utils v0.0.0-20210305010621-2afb4311ab10
) )

366
csi/go.sum Normal file
View File

@ -0,0 +1,366 @@
cloud.google.com/go v0.34.0/go.mod h1:aQUYkXzVsufM+DwF1aE+0xfcU+56JwCaLick0ClmMTw=
cloud.google.com/go v0.38.0/go.mod h1:990N+gfupTy94rShfmMCWGDn0LpTmnzTp2qbd1dvSRU=
cloud.google.com/go v0.44.1/go.mod h1:iSa0KzasP4Uvy3f1mN/7PiObzGgflwredwwASm/v6AU=
cloud.google.com/go v0.44.2/go.mod h1:60680Gw3Yr4ikxnPRS/oxxkBccT6SA1yMk63TGekxKY=
cloud.google.com/go v0.45.1/go.mod h1:RpBamKRgapWJb87xiFSdk4g1CME7QZg3uwTez+TSTjc=
cloud.google.com/go v0.46.3/go.mod h1:a6bKKbmY7er1mI7TEI4lsAkts/mkhTSZK8w33B4RAg0=
cloud.google.com/go v0.51.0/go.mod h1:hWtGJ6gnXH+KgDv+V0zFGDvpi07n3z8ZNj3T1RW0Gcw=
cloud.google.com/go/bigquery v1.0.1/go.mod h1:i/xbL2UlR5RvWAURpBYZTtm/cXjCha9lbfbpx4poX+o=
cloud.google.com/go/datastore v1.0.0/go.mod h1:LXYbyblFSglQ5pkeyhO+Qmw7ukd3C+pD7TKLgZqpHYE=
cloud.google.com/go/pubsub v1.0.1/go.mod h1:R0Gpsv3s54REJCy4fxDixWD93lHJMoZTyQ2kNxGRt3I=
cloud.google.com/go/storage v1.0.0/go.mod h1:IhtSnM/ZTZV8YYJWCY8RULGVqBDmpoyjwiyrjsg+URw=
dmitri.shuralyov.com/gpu/mtl v0.0.0-20190408044501-666a987793e9/go.mod h1:H6x//7gZCb22OMCxBHrMx7a5I7Hp++hsVxbQ4BYO7hU=
github.com/Azure/go-ansiterm v0.0.0-20170929234023-d6e3b3328b78/go.mod h1:LmzpDX56iTiv29bbRTIsUNlaFfuhWRQBWjQdVyAevI8=
github.com/Azure/go-autorest/autorest v0.9.0/go.mod h1:xyHB1BMZT0cuDHU7I0+g046+BFDTQ8rEZB0s4Yfa6bI=
github.com/Azure/go-autorest/autorest v0.9.6/go.mod h1:/FALq9T/kS7b5J5qsQ+RSTUdAmGFqi0vUdVNNx8q630=
github.com/Azure/go-autorest/autorest/adal v0.5.0/go.mod h1:8Z9fGy2MpX0PvDjB1pEgQTmVqjGhiHBW7RJJEciWzS0=
github.com/Azure/go-autorest/autorest/adal v0.8.2/go.mod h1:ZjhuQClTqx435SRJ2iMlOxPYt3d2C/T/7TiQCVZSn3Q=
github.com/Azure/go-autorest/autorest/date v0.1.0/go.mod h1:plvfp3oPSKwf2DNjlBjWF/7vwR+cUD/ELuzDCXwHUVA=
github.com/Azure/go-autorest/autorest/date v0.2.0/go.mod h1:vcORJHLJEh643/Ioh9+vPmf1Ij9AEBM5FuBIXLmIy0g=
github.com/Azure/go-autorest/autorest/mocks v0.1.0/go.mod h1:OTyCOPRA2IgIlWxVYxBee2F5Gr4kF2zd2J5cFRaIDN0=
github.com/Azure/go-autorest/autorest/mocks v0.2.0/go.mod h1:OTyCOPRA2IgIlWxVYxBee2F5Gr4kF2zd2J5cFRaIDN0=
github.com/Azure/go-autorest/autorest/mocks v0.3.0/go.mod h1:a8FDP3DYzQ4RYfVAxAN3SVSiiO77gL2j2ronKKP0syM=
github.com/Azure/go-autorest/logger v0.1.0/go.mod h1:oExouG+K6PryycPJfVSxi/koC6LSNgds39diKLz7Vrc=
github.com/Azure/go-autorest/tracing v0.5.0/go.mod h1:r/s2XiOKccPW3HrqB+W0TQzfbtp2fGCgRFtBroKn4Dk=
github.com/BurntSushi/toml v0.3.1/go.mod h1:xHWCNGjB5oqiDr8zfno3MHue2Ht5sIBksp03qcyfWMU=
github.com/BurntSushi/xgb v0.0.0-20160522181843-27f122750802/go.mod h1:IVnqGOEym/WlBOVXweHU+Q+/VP0lqqI8lqeDx9IjBqo=
github.com/NYTimes/gziphandler v0.0.0-20170623195520-56545f4a5d46/go.mod h1:3wb06e3pkSAbeQ52E9H9iFoQsEEwGN64994WTCIhntQ=
github.com/PuerkitoBio/purell v1.0.0/go.mod h1:c11w/QuzBsJSee3cPx9rAFu61PvFxuPbtSwDGJws/X0=
github.com/PuerkitoBio/urlesc v0.0.0-20160726150825-5bd2802263f2/go.mod h1:uGdkoq3SwY9Y+13GIhn11/XLaGBb4BfwItxLd5jeuXE=
github.com/alecthomas/template v0.0.0-20160405071501-a0175ee3bccc/go.mod h1:LOuyumcjzFXgccqObfd/Ljyb9UuFJ6TxHnclSeseNhc=
github.com/alecthomas/template v0.0.0-20190718012654-fb15b899a751/go.mod h1:LOuyumcjzFXgccqObfd/Ljyb9UuFJ6TxHnclSeseNhc=
github.com/alecthomas/units v0.0.0-20151022065526-2efee857e7cf/go.mod h1:ybxpYRFXyAe+OPACYpWeL0wqObRcbAqCMya13uyzqw0=
github.com/alecthomas/units v0.0.0-20190717042225-c3de453c63f4/go.mod h1:ybxpYRFXyAe+OPACYpWeL0wqObRcbAqCMya13uyzqw0=
github.com/beorn7/perks v0.0.0-20180321164747-3a771d992973/go.mod h1:Dwedo/Wpr24TaqPxmxbtue+5NUziq4I4S80YR8gNf3Q=
github.com/beorn7/perks v1.0.0/go.mod h1:KWe93zE9D1o94FZ5RNwFwVgaQK1VOXiVxmqh+CedLV8=
github.com/beorn7/perks v1.0.1/go.mod h1:G2ZrVWU2WbWT9wwq4/hrbKbnv/1ERSJQ0ibhJ6rlkpw=
github.com/blang/semver v3.5.0+incompatible/go.mod h1:kRBLl5iJ+tD4TcOOxsy/0fnwebNt5EWlYSAyrTnjyyk=
github.com/census-instrumentation/opencensus-proto v0.2.1/go.mod h1:f6KPmirojxKA12rnyqOA5BBL4O983OfeGPqjHWSTneU=
github.com/cespare/xxhash/v2 v2.1.1/go.mod h1:VGX0DQ3Q6kWi7AoAeZDth3/j3BFtOZR5XLFGgcrjCOs=
github.com/chzyer/logex v1.1.10/go.mod h1:+Ywpsq7O8HXn0nuIou7OrIPyXbp3wmkHB+jjWRnGsAI=
github.com/chzyer/readline v0.0.0-20180603132655-2972be24d48e/go.mod h1:nSuG5e5PlCu98SY8svDHJxuZscDgtXS6KTTbou5AhLI=
github.com/chzyer/test v0.0.0-20180213035817-a1ea475d72b1/go.mod h1:Q3SI9o4m/ZMnBNeIyt5eFwwo7qiLfzFZmjNmxjkiQlU=
github.com/container-storage-interface/spec v1.2.0/go.mod h1:6URME8mwIBbpVyZV93Ce5St17xBiQJQY67NDsuohiy4=
github.com/container-storage-interface/spec v1.4.0 h1:ozAshSKxpJnYUfmkpZCTYyF/4MYeYlhdXbAvPvfGmkg=
github.com/container-storage-interface/spec v1.4.0/go.mod h1:6URME8mwIBbpVyZV93Ce5St17xBiQJQY67NDsuohiy4=
github.com/davecgh/go-spew v1.1.0/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
github.com/davecgh/go-spew v1.1.1 h1:vj9j/u1bqnvCEfJOwUhtlOARqs3+rkHYY13jYWTU97c=
github.com/davecgh/go-spew v1.1.1/go.mod h1:J7Y8YcW2NihsgmVo/mv3lAwl/skON4iLHjSsI+c5H38=
github.com/dgrijalva/jwt-go v3.2.0+incompatible/go.mod h1:E3ru+11k8xSBh+hMPgOLZmtrrCbhqsmaPHjLKYnJCaQ=
github.com/docker/spdystream v0.0.0-20160310174837-449fdfce4d96/go.mod h1:Qh8CwZgvJUkLughtfhJv5dyTYa91l1fOUCrgjqmcifM=
github.com/docopt/docopt-go v0.0.0-20180111231733-ee0de3bc6815/go.mod h1:WwZ+bS3ebgob9U8Nd0kOddGdZWjyMGR8Wziv+TBNwSE=
github.com/elazarl/goproxy v0.0.0-20180725130230-947c36da3153/go.mod h1:/Zj4wYkgs4iZTTu3o/KG3Itv/qCCa8VVMlb3i9OVuzc=
github.com/emicklei/go-restful v0.0.0-20170410110728-ff4f55a20633/go.mod h1:otzb+WCGbkyDHkqmQmT5YD2WR4BBwUdeQoFo8l/7tVs=
github.com/envoyproxy/go-control-plane v0.9.0/go.mod h1:YTl/9mNaCwkRvm6d1a2C3ymFceY/DCBVvsKhRF0iEA4=
github.com/envoyproxy/protoc-gen-validate v0.1.0/go.mod h1:iSmxcyjqTsJpI2R4NaDN7+kN2VEUnK/pcBlmesArF7c=
github.com/evanphx/json-patch v4.9.0+incompatible/go.mod h1:50XU6AFN0ol/bzJsmQLiYLvXMP4fmwYFNcr97nuDLSk=
github.com/fsnotify/fsnotify v1.4.7/go.mod h1:jwhsz4b93w/PPRr/qN1Yymfu8t87LnFCMoQvtojpjFo=
github.com/fsnotify/fsnotify v1.4.9/go.mod h1:znqG4EE+3YCdAaPaxE2ZRY/06pZUdp0tY4IgpuI1SZQ=
github.com/ghodss/yaml v0.0.0-20150909031657-73d445a93680/go.mod h1:4dBDuWmgqj2HViK6kFavaiC9ZROes6MMH2rRYeMEF04=
github.com/go-gl/glfw/v3.3/glfw v0.0.0-20191125211704-12ad95a8df72/go.mod h1:tQ2UAYgL5IevRw8kRxooKSPJfGvJ9fJQFa0TUsXzTg8=
github.com/go-kit/kit v0.8.0/go.mod h1:xBxKIO96dXMWWy0MnWVtmwkA9/13aqxPnvrjFYMA2as=
github.com/go-kit/kit v0.9.0/go.mod h1:xBxKIO96dXMWWy0MnWVtmwkA9/13aqxPnvrjFYMA2as=
github.com/go-logfmt/logfmt v0.3.0/go.mod h1:Qt1PoO58o5twSAckw1HlFXLmHsOX5/0LbT9GBnD5lWE=
github.com/go-logfmt/logfmt v0.4.0/go.mod h1:3RMwSq7FuexP4Kalkev3ejPJsZTpXXBr9+V4qmtdjCk=
github.com/go-logr/logr v0.1.0/go.mod h1:ixOQHD9gLJUVQQ2ZOR7zLEifBX6tGkNJF4QyIY7sIas=
github.com/go-logr/logr v0.2.0 h1:QvGt2nLcHH0WK9orKa+ppBPAxREcH364nPUedEpK0TY=
github.com/go-logr/logr v0.2.0/go.mod h1:z6/tIYblkpsD+a4lm/fGIIU9mZ+XfAiaFtq7xTgseGU=
github.com/go-openapi/jsonpointer v0.0.0-20160704185906-46af16f9f7b1/go.mod h1:+35s3my2LFTysnkMfxsJBAMHj/DoqoB9knIWoYG/Vk0=
github.com/go-openapi/jsonreference v0.0.0-20160704190145-13c6e3589ad9/go.mod h1:W3Z9FmVs9qj+KR4zFKmDPGiLdk1D9Rlm7cyMvf57TTg=
github.com/go-openapi/spec v0.0.0-20160808142527-6aced65f8501/go.mod h1:J8+jY1nAiCcj+friV/PDoE1/3eeccG9LYBs0tYvLOWc=
github.com/go-openapi/swag v0.0.0-20160704191624-1d0bd113de87/go.mod h1:DXUve3Dpr1UfpPtxFw+EFuQ41HhCWZfha5jSVRG7C7I=
github.com/go-stack/stack v1.8.0/go.mod h1:v0f6uXyyMGvRgIKkXu+yp6POWl0qKG85gN/melR3HDY=
github.com/gogo/protobuf v1.1.1/go.mod h1:r8qH/GZQm5c6nD/R0oafs1akxWv10x8SbQlK7atdtwQ=
github.com/gogo/protobuf v1.3.1/go.mod h1:SlYgWuQ5SjCEi6WLHjHCa1yvBfUnHcTbrrZtXPKa29o=
github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b h1:VKtxabqXZkF25pY9ekfRL6a582T4P37/31XEstQ5p58=
github.com/golang/glog v0.0.0-20160126235308-23def4e6c14b/go.mod h1:SBH7ygxi8pfUlaOkMMuAQtPIUF8ecWP5IEl/CR7VP2Q=
github.com/golang/groupcache v0.0.0-20190702054246-869f871628b6/go.mod h1:cIg4eruTrX1D+g88fzRXU5OdNfaM+9IcxsU14FzY7Hc=
github.com/golang/groupcache v0.0.0-20191227052852-215e87163ea7/go.mod h1:cIg4eruTrX1D+g88fzRXU5OdNfaM+9IcxsU14FzY7Hc=
github.com/golang/mock v1.1.1/go.mod h1:oTYuIxOrZwtPieC+H1uAHpcLFnEyAGVDL/k47Jfbm0A=
github.com/golang/mock v1.2.0/go.mod h1:oTYuIxOrZwtPieC+H1uAHpcLFnEyAGVDL/k47Jfbm0A=
github.com/golang/mock v1.3.1/go.mod h1:sBzyDLLjw3U8JLTeZvSv8jJB+tU5PVekmnlKIyFUx0Y=
github.com/golang/protobuf v1.2.0/go.mod h1:6lQm79b+lXiMfvg/cZm0SGofjICqVBUtrP5yJMmIC1U=
github.com/golang/protobuf v1.3.1/go.mod h1:6lQm79b+lXiMfvg/cZm0SGofjICqVBUtrP5yJMmIC1U=
github.com/golang/protobuf v1.3.2/go.mod h1:6lQm79b+lXiMfvg/cZm0SGofjICqVBUtrP5yJMmIC1U=
github.com/golang/protobuf v1.3.3/go.mod h1:vzj43D7+SQXF/4pzW/hwtAqwc6iTitCiVSaWz5lYuqw=
github.com/golang/protobuf v1.4.0-rc.1/go.mod h1:ceaxUfeHdC40wWswd/P6IGgMaK3YpKi5j83Wpe3EHw8=
github.com/golang/protobuf v1.4.0-rc.1.0.20200221234624-67d41d38c208/go.mod h1:xKAWHe0F5eneWXFV3EuXVDTCmh+JuBKY0li0aMyXATA=
github.com/golang/protobuf v1.4.0-rc.2/go.mod h1:LlEzMj4AhA7rCAGe4KMBDvJI+AwstrUpVNzEA03Pprs=
github.com/golang/protobuf v1.4.0-rc.4.0.20200313231945-b860323f09d0/go.mod h1:WU3c8KckQ9AFe+yFwt9sWVRKCVIyN9cPHBJSNnbL67w=
github.com/golang/protobuf v1.4.0/go.mod h1:jodUvKwWbYaEsadDk5Fwe5c77LiNKVO9IDvqG2KuDX0=
github.com/golang/protobuf v1.4.1/go.mod h1:U8fpvMrcmy5pZrNK1lt4xCsGvpyWQ/VVv6QDs8UjoX8=
github.com/golang/protobuf v1.4.2 h1:+Z5KGCizgyZCbGh1KZqA0fcLLkwbsjIzS4aV2v7wJX0=
github.com/golang/protobuf v1.4.2/go.mod h1:oDoupMAO8OvCJWAcko0GGGIgR6R6ocIYbsSw735rRwI=
github.com/google/btree v0.0.0-20180813153112-4030bb1f1f0c/go.mod h1:lNA+9X1NB3Zf8V7Ke586lFgjr2dZNuvo3lPJSGZ5JPQ=
github.com/google/btree v1.0.0/go.mod h1:lNA+9X1NB3Zf8V7Ke586lFgjr2dZNuvo3lPJSGZ5JPQ=
github.com/google/go-cmp v0.2.0/go.mod h1:oXzfMopK8JAjlY9xF4vHSVASa0yLyX7SntLO5aqRK0M=
github.com/google/go-cmp v0.3.0/go.mod h1:8QqcDgzrUqlUb/G2PQTWiueGozuR1884gddMywk6iLU=
github.com/google/go-cmp v0.3.1/go.mod h1:8QqcDgzrUqlUb/G2PQTWiueGozuR1884gddMywk6iLU=
github.com/google/go-cmp v0.4.0 h1:xsAVV57WRhGj6kEIi8ReJzQlHHqcBYCElAvkovg3B/4=
github.com/google/go-cmp v0.4.0/go.mod h1:v8dTdLbMG2kIc/vJvl+f65V22dbkXbowE6jgT/gNBxE=
github.com/google/gofuzz v1.0.0/go.mod h1:dBl0BpW6vV/+mYPU4Po3pmUjxk6FQPldtuIdl/M65Eg=
github.com/google/gofuzz v1.1.0/go.mod h1:dBl0BpW6vV/+mYPU4Po3pmUjxk6FQPldtuIdl/M65Eg=
github.com/google/martian v2.1.0+incompatible/go.mod h1:9I4somxYTbIHy5NJKHRl3wXiIaQGbYVAs8BPL6v8lEs=
github.com/google/pprof v0.0.0-20181206194817-3ea8567a2e57/go.mod h1:zfwlbNMJ+OItoe0UupaVj+oy1omPYYDuagoSzA8v9mc=
github.com/google/pprof v0.0.0-20190515194954-54271f7e092f/go.mod h1:zfwlbNMJ+OItoe0UupaVj+oy1omPYYDuagoSzA8v9mc=
github.com/google/pprof v0.0.0-20191218002539-d4f498aebedc/go.mod h1:ZgVRPoUq/hfqzAqh7sHMqb3I9Rq5C59dIz2SbBwJ4eM=
github.com/google/renameio v0.1.0/go.mod h1:KWCgfxg9yswjAJkECMjeO8J8rahYeXnNhOm40UhjYkI=
github.com/google/uuid v1.1.1/go.mod h1:TIyPZe4MgqvfeYDBFedMoGGpEw/LqOeaOT+nhxU+yHo=
github.com/googleapis/gax-go/v2 v2.0.4/go.mod h1:0Wqv26UfaUD9n4G6kQubkQ+KchISgw+vpHVxEJEs9eg=
github.com/googleapis/gax-go/v2 v2.0.5/go.mod h1:DWXyrwAJ9X0FpwwEdw+IPEYBICEFu5mhpdKc/us6bOk=
github.com/googleapis/gnostic v0.4.1/go.mod h1:LRhVm6pbyptWbWbuZ38d1eyptfvIytN3ir6b65WBswg=
github.com/gregjones/httpcache v0.0.0-20180305231024-9cad4c3443a7/go.mod h1:FecbI9+v66THATjSRHfNgh1IVFe/9kFxbXtjV0ctIMA=
github.com/hashicorp/golang-lru v0.5.0/go.mod h1:/m3WP610KZHVQ1SGc6re/UDhFvYD7pJ4Ao+sR/qLZy8=
github.com/hashicorp/golang-lru v0.5.1/go.mod h1:/m3WP610KZHVQ1SGc6re/UDhFvYD7pJ4Ao+sR/qLZy8=
github.com/hpcloud/tail v1.0.0/go.mod h1:ab1qPbhIpdTxEkNHXyeSf5vhxWSCs/tWer42PpOxQnU=
github.com/ianlancetaylor/demangle v0.0.0-20181102032728-5e5cf60278f6/go.mod h1:aSSvb/t6k1mPoxDqO4vJh6VOCGPwU4O0C2/Eqndh1Sc=
github.com/imdario/mergo v0.3.5/go.mod h1:2EnlNZ0deacrJVfApfmtdGgDfMuh/nq6Ok1EcJh5FfA=
github.com/json-iterator/go v1.1.6/go.mod h1:+SdeFBvtyEkXs7REEP0seUULqWtbJapLOCVDaaPEHmU=
github.com/json-iterator/go v1.1.10/go.mod h1:KdQUCv79m/52Kvf8AW2vK1V8akMuk1QjK/uOdHXbAo4=
github.com/jstemmer/go-junit-report v0.0.0-20190106144839-af01ea7f8024/go.mod h1:6v2b51hI/fHJwM22ozAgKL4VKDeJcHhJFhtBdhmNjmU=
github.com/jstemmer/go-junit-report v0.9.1/go.mod h1:Brl9GWCQeLvo8nXZwPNNblvFj/XSXhF0NWZEnDohbsk=
github.com/julienschmidt/httprouter v1.2.0/go.mod h1:SYymIcj16QtmaHHD7aYtjjsJG7VTCxuUUipMqKk8s4w=
github.com/kisielk/errcheck v1.2.0/go.mod h1:/BMXB+zMLi60iA8Vv6Ksmxu/1UDYcXs4uQLJ+jE2L00=
github.com/kisielk/gotool v1.0.0/go.mod h1:XhKaO+MFFWcvkIS/tQcRk01m1F5IRFswLeQ+oQHNcck=
github.com/konsorten/go-windows-terminal-sequences v1.0.1/go.mod h1:T0+1ngSBFLxvqU3pZ+m/2kptfBszLMUkC4ZK/EgS/cQ=
github.com/konsorten/go-windows-terminal-sequences v1.0.3/go.mod h1:T0+1ngSBFLxvqU3pZ+m/2kptfBszLMUkC4ZK/EgS/cQ=
github.com/kr/logfmt v0.0.0-20140226030751-b84e30acd515/go.mod h1:+0opPa2QZZtGFBFZlji/RkVcI2GknAs/DXo4wKdlNEc=
github.com/kr/pretty v0.1.0/go.mod h1:dAy3ld7l9f0ibDNOQOHHMYYIIbhfbHSm3C4ZsoJORNo=
github.com/kr/pretty v0.2.0 h1:s5hAObm+yFO5uHYt5dYjxi2rXrsnmRpJx4OYvIWUaQs=
github.com/kr/pretty v0.2.0/go.mod h1:ipq/a2n7PKx3OHsz4KJII5eveXtPO4qwEXGdVfWzfnI=
github.com/kr/pty v1.1.1/go.mod h1:pFQYn66WHrOpPYNljwOMqo10TkYh1fy3cYio2l3bCsQ=
github.com/kr/text v0.1.0 h1:45sCR5RtlFHMR4UwH9sdQ5TC8v0qDQCHnXt+kaKSTVE=
github.com/kr/text v0.1.0/go.mod h1:4Jbv+DJW3UT/LiOwJeYQe1efqtUx/iVham/4vfdArNI=
github.com/kubernetes-csi/csi-lib-utils v0.9.1 h1:sGq6ifVujfMSkfTsMZip44Ttv8SDXvsBlFk9GdYl/b8=
github.com/kubernetes-csi/csi-lib-utils v0.9.1/go.mod h1:8E2jVUX9j3QgspwHXa6LwyN7IHQDjW9jX3kwoWnSC+M=
github.com/mailru/easyjson v0.0.0-20160728113105-d5b7844b561a/go.mod h1:C1wdFJiN94OJF2b5HbByQZoLdCWB1Yqtg26g4irojpc=
github.com/matttproud/golang_protobuf_extensions v1.0.1/go.mod h1:D8He9yQNgCq6Z5Ld7szi9bcBfOoFv/3dc6xSMkL2PC0=
github.com/matttproud/golang_protobuf_extensions v1.0.2-0.20181231171920-c182affec369/go.mod h1:BSXmuO+STAnVfrANrmjBb36TMTDstsz7MSK+HVaYKv4=
github.com/moby/term v0.0.0-20200312100748-672ec06f55cd/go.mod h1:DdlQx2hp0Ss5/fLikoLlEeIYiATotOjgB//nb973jeo=
github.com/modern-go/concurrent v0.0.0-20180228061459-e0a39a4cb421/go.mod h1:6dJC0mAP4ikYIbvyc7fijjWJddQyLn8Ig3JB5CqoB9Q=
github.com/modern-go/concurrent v0.0.0-20180306012644-bacd9c7ef1dd/go.mod h1:6dJC0mAP4ikYIbvyc7fijjWJddQyLn8Ig3JB5CqoB9Q=
github.com/modern-go/reflect2 v0.0.0-20180701023420-4b7aa43c6742/go.mod h1:bx2lNnkwVCuqBIxFjflWJWanXIb3RllmbCylyMrvgv0=
github.com/modern-go/reflect2 v1.0.1/go.mod h1:bx2lNnkwVCuqBIxFjflWJWanXIb3RllmbCylyMrvgv0=
github.com/munnerz/goautoneg v0.0.0-20120707110453-a547fc61f48d/go.mod h1:+n7T8mK8HuQTcFwEeznm/DIxMOiR9yIdICNftLE1DvQ=
github.com/mwitkow/go-conntrack v0.0.0-20161129095857-cc309e4a2223/go.mod h1:qRWi+5nqEBWmkhHvq77mSJWrCKwh8bxhgT7d/eI7P4U=
github.com/mxk/go-flowrate v0.0.0-20140419014527-cca7078d478f/go.mod h1:ZdcZmHo+o7JKHSa8/e818NopupXU1YMK5fe1lsApnBw=
github.com/onsi/ginkgo v0.0.0-20170829012221-11459a886d9c/go.mod h1:lLunBs/Ym6LB5Z9jYTR76FiuTmxDTDusOGeTQH+WWjE=
github.com/onsi/ginkgo v1.6.0/go.mod h1:lLunBs/Ym6LB5Z9jYTR76FiuTmxDTDusOGeTQH+WWjE=
github.com/onsi/ginkgo v1.11.0/go.mod h1:lLunBs/Ym6LB5Z9jYTR76FiuTmxDTDusOGeTQH+WWjE=
github.com/onsi/gomega v0.0.0-20170829124025-dcabb60a477c/go.mod h1:C1qb7wdrVGGVU+Z6iS04AVkA3Q65CEZX59MT0QO5uiA=
github.com/onsi/gomega v1.7.0/go.mod h1:ex+gbHU/CVuBBDIJjb2X0qEXbFg53c61hWP/1CpauHY=
github.com/peterbourgon/diskv v2.0.1+incompatible/go.mod h1:uqqh8zWWbv1HBMNONnaR/tNboyR3/BZd58JJSHlUSCU=
github.com/pkg/errors v0.8.0/go.mod h1:bwawxfHBFNV+L2hUp1rHADufV3IMtnDRdf1r5NINEl0=
github.com/pkg/errors v0.8.1/go.mod h1:bwawxfHBFNV+L2hUp1rHADufV3IMtnDRdf1r5NINEl0=
github.com/pkg/errors v0.9.1/go.mod h1:bwawxfHBFNV+L2hUp1rHADufV3IMtnDRdf1r5NINEl0=
github.com/pmezard/go-difflib v1.0.0 h1:4DBwDE0NGyQoBHbLQYPwSUPoCMWR5BEzIk/f1lZbAQM=
github.com/pmezard/go-difflib v1.0.0/go.mod h1:iKH77koFhYxTK1pcRnkKkqfTogsbg7gZNVY4sRDYZ/4=
github.com/prometheus/client_golang v0.9.1/go.mod h1:7SWBe2y4D6OKWSNQJUaRYU/AaXPKyh/dDVn+NZz0KFw=
github.com/prometheus/client_golang v1.0.0/go.mod h1:db9x61etRT2tGnBNRi70OPL5FsnadC4Ky3P0J6CfImo=
github.com/prometheus/client_golang v1.7.1/go.mod h1:PY5Wy2awLA44sXw4AOSfFBetzPP4j5+D6mVACh+pe2M=
github.com/prometheus/client_model v0.0.0-20180712105110-5c3871d89910/go.mod h1:MbSGuTsp3dbXC40dX6PRTWyKYBIrTGTE9sqQNg2J8bo=
github.com/prometheus/client_model v0.0.0-20190129233127-fd36f4220a90/go.mod h1:xMI15A0UPsDsEKsMN9yxemIoYk6Tm2C1GtYGdfGttqA=
github.com/prometheus/client_model v0.0.0-20190812154241-14fe0d1b01d4/go.mod h1:xMI15A0UPsDsEKsMN9yxemIoYk6Tm2C1GtYGdfGttqA=
github.com/prometheus/client_model v0.2.0/go.mod h1:xMI15A0UPsDsEKsMN9yxemIoYk6Tm2C1GtYGdfGttqA=
github.com/prometheus/common v0.4.1/go.mod h1:TNfzLD0ON7rHzMJeJkieUDPYmFC7Snx/y86RQel1bk4=
github.com/prometheus/common v0.10.0/go.mod h1:Tlit/dnDKsSWFlCLTWaA1cyBgKHSMdTB80sz/V91rCo=
github.com/prometheus/procfs v0.0.0-20181005140218-185b4288413d/go.mod h1:c3At6R/oaqEKCNdg8wHV1ftS6bRYblBhIjjI8uT2IGk=
github.com/prometheus/procfs v0.0.2/go.mod h1:TjEm7ze935MbeOT/UhFTIMYKhuLP4wbCsTZCD3I8kEA=
github.com/prometheus/procfs v0.1.3/go.mod h1:lV6e/gmhEcM9IjHGsFOCxxuZ+z1YqCvr4OA4YeYWdaU=
github.com/rogpeppe/go-internal v1.3.0/go.mod h1:M8bDsm7K2OlrFYOpmOWEs/qY81heoFRclV5y23lUDJ4=
github.com/sirupsen/logrus v1.2.0/go.mod h1:LxeOpSwHxABJmUn/MG1IvRgCAasNZTLOkJPxbbu5VWo=
github.com/sirupsen/logrus v1.4.2/go.mod h1:tLMulIdttU9McNUspp0xgXVQah82FyeX6MwdIuYE2rE=
github.com/sirupsen/logrus v1.6.0/go.mod h1:7uNnSEd1DgxDLC74fIahvMZmmYsHGZGEOFrfsX/uA88=
github.com/spf13/afero v1.2.2/go.mod h1:9ZxEEn6pIJ8Rxe320qSDBk6AsU0r9pR7Q4OcevTdifk=
github.com/spf13/pflag v0.0.0-20170130214245-9ff6c6923cff/go.mod h1:DYY7MBk1bdzusC3SYhjObp+wFpr4gzcvqqNjLnInEg4=
github.com/spf13/pflag v1.0.3/go.mod h1:DYY7MBk1bdzusC3SYhjObp+wFpr4gzcvqqNjLnInEg4=
github.com/spf13/pflag v1.0.5/go.mod h1:McXfInJRrz4CZXVZOBLb0bTZqETkiAhM9Iw0y3An2Bg=
github.com/stretchr/objx v0.1.0/go.mod h1:HFkY916IF+rwdDfMAkV7OtwuqBVzrE8GR6GFx+wExME=
github.com/stretchr/objx v0.1.1/go.mod h1:HFkY916IF+rwdDfMAkV7OtwuqBVzrE8GR6GFx+wExME=
github.com/stretchr/testify v1.2.2/go.mod h1:a8OnRcib4nhh0OaRAV+Yts87kKdq0PP7pXfy6kDkUVs=
github.com/stretchr/testify v1.3.0/go.mod h1:M5WIy9Dh21IEIfnGCwXGc5bZfKNJtfHm1UVUgZn+9EI=
github.com/stretchr/testify v1.4.0/go.mod h1:j7eGeouHqKxXV5pUuKE4zz7dFj8WfuZ+81PSLYec5m4=
github.com/stretchr/testify v1.5.1 h1:nOGnQDM7FYENwehXlg/kFVnos3rEvtKTjRvOWSzb6H4=
github.com/stretchr/testify v1.5.1/go.mod h1:5W2xD1RspED5o8YsWQXVCued0rvSQ+mT+I5cxcmMvtA=
go.opencensus.io v0.21.0/go.mod h1:mSImk1erAIZhrmZN+AvHh14ztQfjbGwt4TtuofqLduU=
go.opencensus.io v0.22.0/go.mod h1:+kGneAE2xo2IficOXnaByMWTGM9T73dGwxeWcUqIpI8=
go.opencensus.io v0.22.2/go.mod h1:yxeiOL68Rb0Xd1ddK5vPZ/oVn4vY4Ynel7k9FzqtOIw=
go.uber.org/atomic v1.4.0/go.mod h1:gD2HeocX3+yG+ygLZcrzQJaqmWj9AIm7n08wl/qW/PE=
go.uber.org/multierr v1.1.0/go.mod h1:wR5kodmAFQ0UK8QlbwjlSNy0Z68gJhDJUG5sjR94q/0=
go.uber.org/zap v1.10.0/go.mod h1:vwi/ZaCAaUcBkycHslxD9B2zi4UTXhF60s6SWpuDF0Q=
golang.org/x/crypto v0.0.0-20180904163835-0709b304e793/go.mod h1:6SG95UA2DQfeDnfUPMdvaQW0Q7yPrPDi9nlGo2tz2b4=
golang.org/x/crypto v0.0.0-20190308221718-c2843e01d9a2/go.mod h1:djNgcEr1/C05ACkg1iLfiJU5Ep61QUkGW8qpdssI0+w=
golang.org/x/crypto v0.0.0-20190510104115-cbcb75029529/go.mod h1:yigFU9vqHzYiE8UmvKecakEJjdnWj3jj499lnFckfCI=
golang.org/x/crypto v0.0.0-20190605123033-f99c8df09eb5/go.mod h1:yigFU9vqHzYiE8UmvKecakEJjdnWj3jj499lnFckfCI=
golang.org/x/crypto v0.0.0-20191011191535-87dc89f01550/go.mod h1:yigFU9vqHzYiE8UmvKecakEJjdnWj3jj499lnFckfCI=
golang.org/x/crypto v0.0.0-20191206172530-e9b2fee46413/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
golang.org/x/crypto v0.0.0-20200622213623-75b288015ac9/go.mod h1:LzIPMQfyMNhhGPhUkYOs5KpL4U8rLKemX1yGLhDgUto=
golang.org/x/exp v0.0.0-20190121172915-509febef88a4/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
golang.org/x/exp v0.0.0-20190306152737-a1d7652674e8/go.mod h1:CJ0aWSM057203Lf6IL+f9T1iT9GByDxfZKAQTCR3kQA=
golang.org/x/exp v0.0.0-20190510132918-efd6b22b2522/go.mod h1:ZjyILWgesfNpC6sMxTJOJm9Kp84zZh5NQWvqDGG3Qr8=
golang.org/x/exp v0.0.0-20190829153037-c13cbed26979/go.mod h1:86+5VVa7VpoJ4kLfm080zCjGlMRFzhUhsZKEZO7MGek=
golang.org/x/exp v0.0.0-20191227195350-da58074b4299/go.mod h1:2RIsYlXP63K8oxa1u096TMicItID8zy7Y6sNkU49FU4=
golang.org/x/image v0.0.0-20190227222117-0694c2d4d067/go.mod h1:kZ7UVZpmo3dzQBMxlp+ypCbDeSB+sBbTgSJuh5dn5js=
golang.org/x/image v0.0.0-20190802002840-cff245a6509b/go.mod h1:FeLwcggjj3mMvU+oOTbSwawSJRM1uh48EjtB4UJZlP0=
golang.org/x/lint v0.0.0-20190227174305-5b3e6a55c961/go.mod h1:wehouNa3lNwaWXcvxsM5YxQ5yQlVC4a0KAMCusXpPoU=
golang.org/x/lint v0.0.0-20190301231843-5614ed5bae6f/go.mod h1:UVdnD1Gm6xHRNCYTkRU2/jEulfH38KcIWyp/GAMgvoE=
golang.org/x/lint v0.0.0-20190313153728-d0100b6bd8b3/go.mod h1:6SW0HCj/g11FgYtHlgUYUwCkIfeOF89ocIRzGO/8vkc=
golang.org/x/lint v0.0.0-20190409202823-959b441ac422/go.mod h1:6SW0HCj/g11FgYtHlgUYUwCkIfeOF89ocIRzGO/8vkc=
golang.org/x/lint v0.0.0-20190909230951-414d861bb4ac/go.mod h1:6SW0HCj/g11FgYtHlgUYUwCkIfeOF89ocIRzGO/8vkc=
golang.org/x/lint v0.0.0-20191125180803-fdd1cda4f05f/go.mod h1:5qLYkcX4OjUUV8bRuDixDT3tpyyb+LUpUlRWLxfhWrs=
golang.org/x/mobile v0.0.0-20190312151609-d3739f865fa6/go.mod h1:z+o9i4GpDbdi3rU15maQ/Ox0txvL9dWGYEHz965HBQE=
golang.org/x/mobile v0.0.0-20190719004257-d2bd2a29d028/go.mod h1:E/iHnbuqvinMTCcRqshq8CkpyQDoeVncDDYHnLhea+o=
golang.org/x/mod v0.0.0-20190513183733-4bf6d317e70e/go.mod h1:mXi4GBBbnImb6dmsKGUJ2LatrhH/nqhxcFungHvyanc=
golang.org/x/mod v0.1.0/go.mod h1:0QHyrYULN0/3qlju5TqG8bIK38QM8yzMo5ekMj3DlcY=
golang.org/x/mod v0.1.1-0.20191105210325-c90efee705ee/go.mod h1:QqPTAvyqsEbceGzBzNggFXnrqF1CaUcvgkdR5Ot7KZg=
golang.org/x/net v0.0.0-20180724234803-3673e40ba225/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
golang.org/x/net v0.0.0-20180906233101-161cd47e91fd/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
golang.org/x/net v0.0.0-20181114220301-adae6a3d119a/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
golang.org/x/net v0.0.0-20190108225652-1e06a53dbb7e/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
golang.org/x/net v0.0.0-20190213061140-3a22650c66bd/go.mod h1:mL1N/T3taQHkDXs73rZJwtUhF3w3ftmwwsq0BUmARs4=
golang.org/x/net v0.0.0-20190311183353-d8887717615a/go.mod h1:t9HGtf8HONx5eT2rtn7q6eTqICYqUVnKs3thJo3Qplg=
golang.org/x/net v0.0.0-20190404232315-eb5bcb51f2a3/go.mod h1:t9HGtf8HONx5eT2rtn7q6eTqICYqUVnKs3thJo3Qplg=
golang.org/x/net v0.0.0-20190501004415-9ce7a6920f09/go.mod h1:t9HGtf8HONx5eT2rtn7q6eTqICYqUVnKs3thJo3Qplg=
golang.org/x/net v0.0.0-20190503192946-f4e77d36d62c/go.mod h1:t9HGtf8HONx5eT2rtn7q6eTqICYqUVnKs3thJo3Qplg=
golang.org/x/net v0.0.0-20190603091049-60506f45cf65/go.mod h1:HSz+uSET+XFnRR8LxR5pz3Of3rY3CfYBVs4xY44aLks=
golang.org/x/net v0.0.0-20190613194153-d28f0bde5980/go.mod h1:z5CRVTTTmAJ677TzLLGU+0bjPO0LkuOLi4/5GtJWs/s=
golang.org/x/net v0.0.0-20190620200207-3b0461eec859/go.mod h1:z5CRVTTTmAJ677TzLLGU+0bjPO0LkuOLi4/5GtJWs/s=
golang.org/x/net v0.0.0-20191209160850-c0dbc17a3553/go.mod h1:z5CRVTTTmAJ677TzLLGU+0bjPO0LkuOLi4/5GtJWs/s=
golang.org/x/net v0.0.0-20200324143707-d3edc9973b7e/go.mod h1:qpuaurCH72eLCgpAm/N6yyVIVM9cpaDIP3A8BGJEC5A=
golang.org/x/net v0.0.0-20200707034311-ab3426394381/go.mod h1:/O7V0waA8r7cgGh81Ro3o1hOxt32SMVPicZroKQ2sZA=
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb h1:eBmm0M9fYhWpKZLjQUUKka/LtIxf46G4fxeEz5KJr9U=
golang.org/x/net v0.0.0-20201202161906-c7110b5ffcbb/go.mod h1:sp8m0HH+o8qH0wwXwYZr8TS3Oi6o0r6Gce1SSxlDquU=
golang.org/x/oauth2 v0.0.0-20180821212333-d2e6202438be/go.mod h1:N/0e6XlmueqKjAGxoOufVs8QHGRruUQn6yWY3a++T0U=
golang.org/x/oauth2 v0.0.0-20190226205417-e64efc72b421/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
golang.org/x/oauth2 v0.0.0-20190604053449-0f29369cfe45/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
golang.org/x/oauth2 v0.0.0-20191202225959-858c2ad4c8b6/go.mod h1:gOpvHmFTYa4IltrdGE7lF6nIHvwfUNPOp7c8zoXwtLw=
golang.org/x/sync v0.0.0-20180314180146-1d60e4601c6f/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sync v0.0.0-20181108010431-42b317875d0f/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sync v0.0.0-20181221193216-37e7f081c4d4/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sync v0.0.0-20190227155943-e225da77a7e6/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sync v0.0.0-20190423024810-112230192c58/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sync v0.0.0-20190911185100-cd5d95a43a6e/go.mod h1:RxMgew5VJxzue5/jJTE5uejpjVlOe/izrB70Jof72aM=
golang.org/x/sys v0.0.0-20180905080454-ebe1bf3edb33/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
golang.org/x/sys v0.0.0-20180909124046-d0be0721c37e/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
golang.org/x/sys v0.0.0-20181116152217-5ac8a444bdc5/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
golang.org/x/sys v0.0.0-20190215142949-d0b11bdaac8a/go.mod h1:STP8DvDyc/dI5b8T5hshtkjS+E42TnysNCUPdjciGhY=
golang.org/x/sys v0.0.0-20190312061237-fead79001313/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190412213103-97732733099d/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190422165155-953cdadca894/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190502145724-3ef323f4f1fd/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190507160741-ecd444e8653b/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190606165138-5da285871e9c/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20190624142023-c5567b49c5d0/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20191005200804-aed5e4c7ecf9/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20191204072324-ce4227a45e2e/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20191228213918-04cbcbbfeed8/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200106162015-b016eb3dc98e/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200302150141-5c8b2ff67527/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200323222414-85ca7c5b95cd/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200615200032-f1bc736245b1/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200622214017-ed371f2e16b4/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/sys v0.0.0-20200930185726-fdedc70b468f h1:+Nyd8tzPX9R7BWHguqsrbFdRx3WQ/1ib8I44HXV5yTA=
golang.org/x/sys v0.0.0-20200930185726-fdedc70b468f/go.mod h1:h1NjWce9XRLGQEsW7wpKNCjG9DtNlClVuFLEZdDNbEs=
golang.org/x/text v0.3.0/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
golang.org/x/text v0.3.1-0.20180807135948-17ff2d5776d2/go.mod h1:NqM8EUOU14njkJ3fqMW+pc6Ldnwhi/IjpwHt7yyuwOQ=
golang.org/x/text v0.3.2/go.mod h1:bEr9sfX3Q8Zfm5fL9x+3itogRgK3+ptLWKqgva+5dAk=
golang.org/x/text v0.3.3 h1:cokOdA+Jmi5PJGXLlLllQSgYigAEfHXJAERHVMaCc2k=
golang.org/x/text v0.3.3/go.mod h1:5Zoc/QRtKVWzQhOtBMvqHzDpF6irO9z98xDceosuGiQ=
golang.org/x/time v0.0.0-20181108054448-85acf8d2951c/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
golang.org/x/time v0.0.0-20190308202827-9d24e82272b4/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
golang.org/x/time v0.0.0-20191024005414-555d28b269f0/go.mod h1:tRJNPiyCQ0inRvYxbN9jk5I+vvW/OXSQhTDSoE431IQ=
golang.org/x/tools v0.0.0-20180917221912-90fa682c2a6e/go.mod h1:n7NCudcB/nEzxVGmLbDWY5pfWTLqBcC2KZ6jyYvM4mQ=
golang.org/x/tools v0.0.0-20181011042414-1f849cf54d09/go.mod h1:n7NCudcB/nEzxVGmLbDWY5pfWTLqBcC2KZ6jyYvM4mQ=
golang.org/x/tools v0.0.0-20181030221726-6c7e314b6563/go.mod h1:n7NCudcB/nEzxVGmLbDWY5pfWTLqBcC2KZ6jyYvM4mQ=
golang.org/x/tools v0.0.0-20190226205152-f727befe758c/go.mod h1:9Yl7xja0Znq3iFh3HoIrodX9oNMXvdceNzlUR8zjMvY=
golang.org/x/tools v0.0.0-20190311212946-11955173bddd/go.mod h1:LCzVGOaR6xXOjkQ3onu1FJEFr0SW1gC7cKk1uF8kGRs=
golang.org/x/tools v0.0.0-20190312151545-0bb0c0a6e846/go.mod h1:LCzVGOaR6xXOjkQ3onu1FJEFr0SW1gC7cKk1uF8kGRs=
golang.org/x/tools v0.0.0-20190312170243-e65039ee4138/go.mod h1:LCzVGOaR6xXOjkQ3onu1FJEFr0SW1gC7cKk1uF8kGRs=
golang.org/x/tools v0.0.0-20190425150028-36563e24a262/go.mod h1:RgjU9mgBXZiqYHBnxXauZ1Gv1EHHAz9KjViQ78xBX0Q=
golang.org/x/tools v0.0.0-20190506145303-2d16b83fe98c/go.mod h1:RgjU9mgBXZiqYHBnxXauZ1Gv1EHHAz9KjViQ78xBX0Q=
golang.org/x/tools v0.0.0-20190524140312-2c0ae7006135/go.mod h1:RgjU9mgBXZiqYHBnxXauZ1Gv1EHHAz9KjViQ78xBX0Q=
golang.org/x/tools v0.0.0-20190606124116-d0a3d012864b/go.mod h1:/rFqwRUd4F7ZHNgwSSTFct+R/Kf4OFW1sUzUTQQTgfc=
golang.org/x/tools v0.0.0-20190621195816-6e04913cbbac/go.mod h1:/rFqwRUd4F7ZHNgwSSTFct+R/Kf4OFW1sUzUTQQTgfc=
golang.org/x/tools v0.0.0-20190624222133-a101b041ded4/go.mod h1:/rFqwRUd4F7ZHNgwSSTFct+R/Kf4OFW1sUzUTQQTgfc=
golang.org/x/tools v0.0.0-20190628153133-6cdbf07be9d0/go.mod h1:/rFqwRUd4F7ZHNgwSSTFct+R/Kf4OFW1sUzUTQQTgfc=
golang.org/x/tools v0.0.0-20190816200558-6889da9d5479/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
golang.org/x/tools v0.0.0-20190911174233-4f2ddba30aff/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
golang.org/x/tools v0.0.0-20191012152004-8de300cfc20a/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
golang.org/x/tools v0.0.0-20191125144606-a911d9008d1f/go.mod h1:b+2E5dAYhXwXZwtnZ6UAqBI28+e2cm9otk0dWdXHAEo=
golang.org/x/tools v0.0.0-20191227053925-7b8e75db28f4/go.mod h1:TB2adYChydJhpapKDTa4BR/hXlZSLoq2Wpct/0txZ28=
golang.org/x/xerrors v0.0.0-20190717185122-a985d3407aa7/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
golang.org/x/xerrors v0.0.0-20191011141410-1b5146add898/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
golang.org/x/xerrors v0.0.0-20191204190536-9bdfabe68543/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
golang.org/x/xerrors v0.0.0-20200804184101-5ec99f83aff1 h1:go1bK/D/BFZV2I8cIQd1NKEZ+0owSTG1fDTci4IqFcE=
golang.org/x/xerrors v0.0.0-20200804184101-5ec99f83aff1/go.mod h1:I/5z698sn9Ka8TeJc9MKroUUfqBBauWjQqLJ2OPfmY0=
google.golang.org/api v0.4.0/go.mod h1:8k5glujaEP+g9n7WNsDg8QP6cUVNI86fCNMcbazEtwE=
google.golang.org/api v0.7.0/go.mod h1:WtwebWUNSVBH/HAw79HIFXZNqEvBhG+Ra+ax0hx3E3M=
google.golang.org/api v0.8.0/go.mod h1:o4eAsZoiT+ibD93RtjEohWalFOjRDx6CVaqeizhEnKg=
google.golang.org/api v0.9.0/go.mod h1:o4eAsZoiT+ibD93RtjEohWalFOjRDx6CVaqeizhEnKg=
google.golang.org/api v0.15.0/go.mod h1:iLdEw5Ide6rF15KTC1Kkl0iskquN2gFfn9o9XIsbkAI=
google.golang.org/appengine v1.4.0/go.mod h1:xpcJRLb0r/rnEns0DIKYYv+WjYCduHsrkT7/EB5XEv4=
google.golang.org/appengine v1.5.0/go.mod h1:xpcJRLb0r/rnEns0DIKYYv+WjYCduHsrkT7/EB5XEv4=
google.golang.org/appengine v1.6.1/go.mod h1:i06prIuMbXzDqacNJfV5OdTW448YApPu5ww/cMBSeb0=
google.golang.org/appengine v1.6.5/go.mod h1:8WjMMxjGQR8xUklV/ARdw2HLXBOI7O7uCIDZVag1xfc=
google.golang.org/genproto v0.0.0-20190307195333-5fe7a883aa19/go.mod h1:VzzqZJRnGkLBvHegQrXjBqPurQTc5/KpmUdxsrq26oE=
google.golang.org/genproto v0.0.0-20190418145605-e7d98fc518a7/go.mod h1:VzzqZJRnGkLBvHegQrXjBqPurQTc5/KpmUdxsrq26oE=
google.golang.org/genproto v0.0.0-20190425155659-357c62f0e4bb/go.mod h1:VzzqZJRnGkLBvHegQrXjBqPurQTc5/KpmUdxsrq26oE=
google.golang.org/genproto v0.0.0-20190502173448-54afdca5d873/go.mod h1:VzzqZJRnGkLBvHegQrXjBqPurQTc5/KpmUdxsrq26oE=
google.golang.org/genproto v0.0.0-20190801165951-fa694d86fc64/go.mod h1:DMBHOl98Agz4BDEuKkezgsaosCRResVns1a3J2ZsMNc=
google.golang.org/genproto v0.0.0-20190819201941-24fa4b261c55/go.mod h1:DMBHOl98Agz4BDEuKkezgsaosCRResVns1a3J2ZsMNc=
google.golang.org/genproto v0.0.0-20190911173649-1774047e7e51/go.mod h1:IbNlFCBrqXvoKpeg0TB2l7cyZUmoaFKYIwrEpbDKLA8=
google.golang.org/genproto v0.0.0-20191230161307-f3c370f40bfb/go.mod h1:n3cpQtvxv34hfy77yVDNjmbRyujviMdxYliBSkLhpCc=
google.golang.org/genproto v0.0.0-20200526211855-cb27e3aa2013 h1:+kGHl1aib/qcwaRi1CbqBZ1rk19r85MNUf8HaBghugY=
google.golang.org/genproto v0.0.0-20200526211855-cb27e3aa2013/go.mod h1:NbSheEEYHJ7i3ixzK3sjbqSGDJWnxyFXZblF3eUsNvo=
google.golang.org/grpc v1.25.1 h1:wdKvqQk7IttEw92GoRyKG2IDrUIpgpj6H6m81yfeMW0=
google.golang.org/grpc v1.25.1/go.mod h1:c3i+UQWmh7LiEpx4sFZnkU36qjEYZ0imhYfXVyQciAY=
google.golang.org/protobuf v0.0.0-20200109180630-ec00e32a8dfd/go.mod h1:DFci5gLYBciE7Vtevhsrf46CRTquxDuWsQurQQe4oz8=
google.golang.org/protobuf v0.0.0-20200221191635-4d8936d0db64/go.mod h1:kwYJMbMJ01Woi6D6+Kah6886xMZcty6N08ah7+eCXa0=
google.golang.org/protobuf v0.0.0-20200228230310-ab0ca4ff8a60/go.mod h1:cfTl7dwQJ+fmap5saPgwCLgHXTUD7jkjRqWcaiX5VyM=
google.golang.org/protobuf v1.20.1-0.20200309200217-e05f789c0967/go.mod h1:A+miEFZTKqfCUM6K7xSMQL9OKL/b6hQv+e19PK+JZNE=
google.golang.org/protobuf v1.21.0/go.mod h1:47Nbq4nVaFHyn7ilMalzfO3qCViNmqZ2kzikPIcrTAo=
google.golang.org/protobuf v1.22.0/go.mod h1:EGpADcykh3NcUnDUJcl1+ZksZNG86OlYog2l/sGQquU=
google.golang.org/protobuf v1.23.0/go.mod h1:EGpADcykh3NcUnDUJcl1+ZksZNG86OlYog2l/sGQquU=
google.golang.org/protobuf v1.23.1-0.20200526195155-81db48ad09cc/go.mod h1:EGpADcykh3NcUnDUJcl1+ZksZNG86OlYog2l/sGQquU=
google.golang.org/protobuf v1.24.0 h1:UhZDfRO8JRQru4/+LlLE0BRKGF8L+PICnvYZmx/fEGA=
google.golang.org/protobuf v1.24.0/go.mod h1:r/3tXBNzIEhYS9I1OUVjXDlt8tc493IdKGjtUeSXeh4=
gopkg.in/alecthomas/kingpin.v2 v2.2.6/go.mod h1:FMv+mEhP44yOT+4EoQTLFTRgOQ1FBLkstjWtayDeSgw=
gopkg.in/check.v1 v0.0.0-20161208181325-20d25e280405/go.mod h1:Co6ibVJAznAaIkqp8huTwlJQCZ016jof/cbN4VW5Yz0=
gopkg.in/check.v1 v1.0.0-20180628173108-788fd7840127/go.mod h1:Co6ibVJAznAaIkqp8huTwlJQCZ016jof/cbN4VW5Yz0=
gopkg.in/check.v1 v1.0.0-20190902080502-41f04d3bba15 h1:YR8cESwS4TdDjEe65xsg0ogRM/Nc3DYOhEAlW+xobZo=
gopkg.in/check.v1 v1.0.0-20190902080502-41f04d3bba15/go.mod h1:Co6ibVJAznAaIkqp8huTwlJQCZ016jof/cbN4VW5Yz0=
gopkg.in/errgo.v2 v2.1.0/go.mod h1:hNsd1EY+bozCKY1Ytp96fpM3vjJbqLJn88ws8XvfDNI=
gopkg.in/fsnotify.v1 v1.4.7/go.mod h1:Tz8NjZHkW78fSQdbUxIjBTcgA1z1m8ZHf0WmKUhAMys=
gopkg.in/inf.v0 v0.9.1/go.mod h1:cWUDdTG/fYaXco+Dcufb5Vnc6Gp2YChqWtbxRZE0mXw=
gopkg.in/tomb.v1 v1.0.0-20141024135613-dd632973f1e7/go.mod h1:dt/ZhP58zS4L8KSrWDmTeBkI65Dw0HsyUHuEVlX15mw=
gopkg.in/yaml.v2 v2.2.1/go.mod h1:hI93XBmqTisBFMUTm0b8Fm+jr3Dg1NNxqwp+5A1VGuI=
gopkg.in/yaml.v2 v2.2.2/go.mod h1:hI93XBmqTisBFMUTm0b8Fm+jr3Dg1NNxqwp+5A1VGuI=
gopkg.in/yaml.v2 v2.2.4/go.mod h1:hI93XBmqTisBFMUTm0b8Fm+jr3Dg1NNxqwp+5A1VGuI=
gopkg.in/yaml.v2 v2.2.5/go.mod h1:hI93XBmqTisBFMUTm0b8Fm+jr3Dg1NNxqwp+5A1VGuI=
gopkg.in/yaml.v2 v2.2.8 h1:obN1ZagJSUGI0Ek/LBmuj4SNLPfIny3KsKFopxRdj10=
gopkg.in/yaml.v2 v2.2.8/go.mod h1:hI93XBmqTisBFMUTm0b8Fm+jr3Dg1NNxqwp+5A1VGuI=
gotest.tools v2.2.0+incompatible/go.mod h1:DsYFclhRJ6vuDpmuTbkuFWG+y2sxOXAzmJt81HFBacw=
gotest.tools/v3 v3.0.2/go.mod h1:3SzNCllyD9/Y+b5r9JIKQ474KzkZyqLqEfYqMsX94Bk=
honnef.co/go/tools v0.0.0-20190102054323-c2f93a96b099/go.mod h1:rf3lG4BRIbNafJWhAfAdb/ePZxsR/4RtNHQocxwk9r4=
honnef.co/go/tools v0.0.0-20190106161140-3f1c8253044a/go.mod h1:rf3lG4BRIbNafJWhAfAdb/ePZxsR/4RtNHQocxwk9r4=
honnef.co/go/tools v0.0.0-20190418001031-e561f6794a2a/go.mod h1:rf3lG4BRIbNafJWhAfAdb/ePZxsR/4RtNHQocxwk9r4=
honnef.co/go/tools v0.0.0-20190523083050-ea95bdfd59fc/go.mod h1:rf3lG4BRIbNafJWhAfAdb/ePZxsR/4RtNHQocxwk9r4=
honnef.co/go/tools v0.0.1-2019.2.3/go.mod h1:a3bituU0lyd329TUQxRnasdCoJDkEUEAqEt0JzvZhAg=
k8s.io/api v0.19.0/go.mod h1:I1K45XlvTrDjmj5LoM5LuP/KYrhWbjUKT/SoPG0qTjw=
k8s.io/apimachinery v0.19.0/go.mod h1:DnPGDnARWFvYa3pMHgSxtbZb7gpzzAZ1pTfaUNDVlmA=
k8s.io/client-go v0.19.0/go.mod h1:H9E/VT95blcFQnlyShFgnFT9ZnJOAceiUHM3MlRC+mU=
k8s.io/component-base v0.19.0/go.mod h1:dKsY8BxkA+9dZIAh2aWJLL/UdASFDNtGYTCItL4LM7Y=
k8s.io/gengo v0.0.0-20200413195148-3a45101e95ac/go.mod h1:ezvh/TsK7cY6rbqRK0oQQ8IAqLxYwwyPxAX1Pzy0ii0=
k8s.io/klog v1.0.0 h1:Pt+yjF5aB1xDSVbau4VsWe+dQNzA0qv1LlXdC2dF6Q8=
k8s.io/klog v1.0.0/go.mod h1:4Bi6QPql/J/LkTDqv7R/cd3hPo4k2DG6Ptcz060Ez5I=
k8s.io/klog/v2 v2.0.0/go.mod h1:PBfzABfn139FHAV07az/IF9Wp1bkk3vpT2XSJ76fSDE=
k8s.io/klog/v2 v2.2.0 h1:XRvcwJozkgZ1UQJmfMGpvRthQHOvihEhYtDfAaxMz/A=
k8s.io/klog/v2 v2.2.0/go.mod h1:Od+F08eJP+W3HUb4pSrPpgp9DGU4GzlpG/TmITuYh/Y=
k8s.io/kube-openapi v0.0.0-20200805222855-6aeccd4b50c6/go.mod h1:UuqjUnNftUyPE5H64/qeyjQoUZhGpeFDVdxjTeEVN2o=
k8s.io/utils v0.0.0-20200729134348-d5654de09c73/go.mod h1:jPW/WVKK9YHAvNhRxK0md/EJ228hCsBRufyofKtW8HA=
k8s.io/utils v0.0.0-20210305010621-2afb4311ab10 h1:u5rPykqiCpL+LBfjRkXvnK71gOgIdmq3eHUEkPrbeTI=
k8s.io/utils v0.0.0-20210305010621-2afb4311ab10/go.mod h1:jPW/WVKK9YHAvNhRxK0md/EJ228hCsBRufyofKtW8HA=
rsc.io/binaryregexp v0.2.0/go.mod h1:qTv7/COck+e2FymRvadv62gMdZztPaShugOCi3I+8D8=
sigs.k8s.io/structured-merge-diff/v4 v4.0.1/go.mod h1:bJZC9H9iH24zzfZ/41RGcq60oK1F7G282QMXDPYydCw=
sigs.k8s.io/yaml v1.1.0/go.mod h1:UJmg0vDUVViEyp3mgSv9WPwZCDxu4rQW1olrI1uml+o=
sigs.k8s.io/yaml v1.2.0/go.mod h1:yfXDCHCao9+ENCvLSE62v9VSji2MKu5jeNfTrofGhJc=

View File

@ -5,7 +5,7 @@ package vitastor
const ( const (
vitastorCSIDriverName = "csi.vitastor.io" vitastorCSIDriverName = "csi.vitastor.io"
vitastorCSIDriverVersion = "0.6.4" vitastorCSIDriverVersion = "1.6.1"
) )
// Config struct fills the parameters of request or user input // Config struct fills the parameters of request or user input

View File

@ -6,11 +6,11 @@ package vitastor
import ( import (
"context" "context"
"encoding/json" "encoding/json"
"fmt"
"strings" "strings"
"bytes" "bytes"
"strconv" "strconv"
"time" "time"
"fmt"
"os" "os"
"os/exec" "os/exec"
"io/ioutil" "io/ioutil"
@ -20,8 +20,7 @@ import (
"google.golang.org/grpc/codes" "google.golang.org/grpc/codes"
"google.golang.org/grpc/status" "google.golang.org/grpc/status"
"google.golang.org/protobuf/types/known/timestamppb"
"go.etcd.io/etcd/clientv3"
"github.com/container-storage-interface/spec/lib/go/csi" "github.com/container-storage-interface/spec/lib/go/csi"
) )
@ -47,6 +46,7 @@ type InodeConfig struct
ParentPool uint64 `json:"parent_pool,omitempty"` ParentPool uint64 `json:"parent_pool,omitempty"`
ParentId uint64 `json:"parent_id,omitempty"` ParentId uint64 `json:"parent_id,omitempty"`
Readonly bool `json:"readonly,omitempty"` Readonly bool `json:"readonly,omitempty"`
CreateTs uint64 `json:"create_ts,omitempty"`
} }
type ControllerServer struct type ControllerServer struct
@ -62,7 +62,7 @@ func NewControllerServer(driver *Driver) *ControllerServer
} }
} }
func GetConnectionParams(params map[string]string) (map[string]string, []string, string) func GetConnectionParams(params map[string]string) (map[string]string, error)
{ {
ctxVars := make(map[string]string) ctxVars := make(map[string]string)
configPath := params["configPath"] configPath := params["configPath"]
@ -75,43 +75,69 @@ func GetConnectionParams(params map[string]string) (map[string]string, []string,
ctxVars["configPath"] = configPath ctxVars["configPath"] = configPath
} }
config := make(map[string]interface{}) config := make(map[string]interface{})
if configFD, err := os.Open(configPath); err == nil configFD, err := os.Open(configPath)
if (err != nil)
{ {
defer configFD.Close() return nil, err
data, _ := ioutil.ReadAll(configFD)
json.Unmarshal(data, &config)
} }
// Try to load prefix & etcd URL from the config defer configFD.Close()
data, _ := ioutil.ReadAll(configFD)
json.Unmarshal(data, &config)
// Check etcd URL in the config, but do not use the explicit etcdUrl
// parameter for CLI calls, otherwise users won't be able to later
// change them - storage class parameters are saved in volume IDs
var etcdUrl []string var etcdUrl []string
if (params["etcdUrl"] != "") switch config["etcd_address"].(type)
{ {
ctxVars["etcdUrl"] = params["etcdUrl"] case string:
etcdUrl = strings.Split(params["etcdUrl"], ",") url := strings.TrimSpace(config["etcd_address"].(string))
if (url != "")
{
etcdUrl = strings.Split(url, ",")
}
case []string:
etcdUrl = config["etcd_address"].([]string)
case []interface{}:
for _, url := range config["etcd_address"].([]interface{})
{
s, ok := url.(string)
if (ok)
{
etcdUrl = append(etcdUrl, s)
}
}
} }
if (len(etcdUrl) == 0) if (len(etcdUrl) == 0)
{ {
switch config["etcd_address"].(type) return nil, status.Error(codes.InvalidArgument, "etcd_address is missing in "+configPath)
{
case string:
etcdUrl = strings.Split(config["etcd_address"].(string), ",")
case []string:
etcdUrl = config["etcd_address"].([]string)
}
} }
etcdPrefix := params["etcdPrefix"] return ctxVars, nil
if (etcdPrefix == "") }
func system(program string, args ...string) ([]byte, []byte, error)
{
klog.Infof("Running "+program+" "+strings.Join(args, " "))
c := exec.Command(program, args...)
var stdout, stderr bytes.Buffer
c.Stdout, c.Stderr = &stdout, &stderr
err := c.Run()
if (err != nil)
{ {
etcdPrefix, _ = config["etcd_prefix"].(string) stdoutStr, stderrStr := string(stdout.Bytes()), string(stderr.Bytes())
if (etcdPrefix == "") klog.Errorf(program+" "+strings.Join(args, " ")+" failed: %s, status %s\n", stdoutStr+stderrStr, err)
{ return nil, nil, status.Error(codes.Internal, stdoutStr+stderrStr+" (status "+err.Error()+")")
etcdPrefix = "/vitastor"
}
} }
else return stdout.Bytes(), stderr.Bytes(), nil
}
func invokeCLI(ctxVars map[string]string, args []string) ([]byte, error)
{
if (ctxVars["configPath"] != "")
{ {
ctxVars["etcdPrefix"] = etcdPrefix args = append(args, "--config_path", ctxVars["configPath"])
} }
return ctxVars, etcdUrl, etcdPrefix stdout, _, err := system("/usr/bin/vitastor-cli", args...)
return stdout, err
} }
// Create the volume // Create the volume
@ -146,128 +172,57 @@ func (cs *ControllerServer) CreateVolume(ctx context.Context, req *csi.CreateVol
volSize = ((capRange.GetRequiredBytes() + MB - 1) / MB) * MB volSize = ((capRange.GetRequiredBytes() + MB - 1) / MB) * MB
} }
// FIXME: The following should PROBABLY be implemented externally in a management tool ctxVars, err := GetConnectionParams(req.Parameters)
ctxVars, etcdUrl, etcdPrefix := GetConnectionParams(req.Parameters)
if (len(etcdUrl) == 0)
{
return nil, status.Error(codes.InvalidArgument, "no etcdUrl in storage class configuration and no etcd_address in vitastor.conf")
}
// Connect to etcd
cli, err := clientv3.New(clientv3.Config{
DialTimeout: ETCD_TIMEOUT,
Endpoints: etcdUrl,
})
if (err != nil) if (err != nil)
{ {
return nil, status.Error(codes.Internal, "failed to connect to etcd at "+strings.Join(etcdUrl, ",")+": "+err.Error()) return nil, err
} }
defer cli.Close()
var imageId uint64 = 0 args := []string{ "create", volName, "-s", fmt.Sprintf("%v", volSize), "--pool", fmt.Sprintf("%v", poolId) }
for
// Support creation from snapshot
var src *csi.VolumeContentSource
if (req.VolumeContentSource.GetSnapshot() != nil)
{ {
// Check if the image exists snapId := req.VolumeContentSource.GetSnapshot().GetSnapshotId()
ctx, cancel := context.WithTimeout(context.Background(), ETCD_TIMEOUT) if (snapId != "")
resp, err := cli.Get(ctx, etcdPrefix+"/index/image/"+volName)
cancel()
if (err != nil)
{ {
return nil, status.Error(codes.Internal, "failed to read key from etcd: "+err.Error()) snapVars := make(map[string]string)
err := json.Unmarshal([]byte(snapId), &snapVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
args = append(args, "--parent", snapVars["name"]+"@"+snapVars["snapshot"])
src = &csi.VolumeContentSource{
Type: &csi.VolumeContentSource_Snapshot{
Snapshot: &csi.VolumeContentSource_SnapshotSource{
SnapshotId: snapId,
},
},
}
} }
if (len(resp.Kvs) > 0) }
// Create image using vitastor-cli
_, err = invokeCLI(ctxVars, args)
if (err != nil)
{
if (strings.Index(err.Error(), "already exists") > 0)
{ {
kv := resp.Kvs[0] inodeCfg, err := invokeList(ctxVars, volName, true)
var v InodeIndex
err := json.Unmarshal(kv.Value, &v)
if (err != nil) if (err != nil)
{ {
return nil, status.Error(codes.Internal, "invalid /index/image/"+volName+" key in etcd: "+err.Error()) return nil, err
} }
poolId = v.PoolId if (inodeCfg[0].Size < uint64(volSize))
imageId = v.Id
inodeCfgKey := fmt.Sprintf("/config/inode/%d/%d", poolId, imageId)
ctx, cancel := context.WithTimeout(context.Background(), ETCD_TIMEOUT)
resp, err := cli.Get(ctx, etcdPrefix+inodeCfgKey)
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to read key from etcd: "+err.Error())
}
if (len(resp.Kvs) == 0)
{
return nil, status.Error(codes.Internal, "missing "+inodeCfgKey+" key in etcd")
}
var inodeCfg InodeConfig
err = json.Unmarshal(resp.Kvs[0].Value, &inodeCfg)
if (err != nil)
{
return nil, status.Error(codes.Internal, "invalid "+inodeCfgKey+" key in etcd: "+err.Error())
}
if (inodeCfg.Size < uint64(volSize))
{ {
return nil, status.Error(codes.Internal, "image "+volName+" is already created, but size is less than expected") return nil, status.Error(codes.Internal, "image "+volName+" is already created, but size is less than expected")
} }
} }
else else
{ {
// Find a free ID return nil, err
// Create image metadata in a transaction verifying that the image doesn't exist yet AND ID is still free
maxIdKey := fmt.Sprintf("%s/index/maxid/%d", etcdPrefix, poolId)
ctx, cancel := context.WithTimeout(context.Background(), ETCD_TIMEOUT)
resp, err := cli.Get(ctx, maxIdKey)
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to read key from etcd: "+err.Error())
}
var modRev int64
var nextId uint64
if (len(resp.Kvs) > 0)
{
var err error
nextId, err = strconv.ParseUint(string(resp.Kvs[0].Value), 10, 64)
if (err != nil)
{
return nil, status.Error(codes.Internal, maxIdKey+" contains invalid ID")
}
modRev = resp.Kvs[0].ModRevision
nextId++
}
else
{
nextId = 1
}
inodeIdxJson, _ := json.Marshal(InodeIndex{
Id: nextId,
PoolId: poolId,
})
inodeCfgJson, _ := json.Marshal(InodeConfig{
Name: volName,
Size: uint64(volSize),
})
ctx, cancel = context.WithTimeout(context.Background(), ETCD_TIMEOUT)
txnResp, err := cli.Txn(ctx).If(
clientv3.Compare(clientv3.ModRevision(fmt.Sprintf("%s/index/maxid/%d", etcdPrefix, poolId)), "=", modRev),
clientv3.Compare(clientv3.CreateRevision(fmt.Sprintf("%s/index/image/%s", etcdPrefix, volName)), "=", 0),
clientv3.Compare(clientv3.CreateRevision(fmt.Sprintf("%s/config/inode/%d/%d", etcdPrefix, poolId, nextId)), "=", 0),
).Then(
clientv3.OpPut(fmt.Sprintf("%s/index/maxid/%d", etcdPrefix, poolId), fmt.Sprintf("%d", nextId)),
clientv3.OpPut(fmt.Sprintf("%s/index/image/%s", etcdPrefix, volName), string(inodeIdxJson)),
clientv3.OpPut(fmt.Sprintf("%s/config/inode/%d/%d", etcdPrefix, poolId, nextId), string(inodeCfgJson)),
).Commit()
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to commit transaction in etcd: "+err.Error())
}
if (txnResp.Succeeded)
{
imageId = nextId
break
}
// Start over if the transaction fails
} }
} }
@ -278,6 +233,7 @@ func (cs *ControllerServer) CreateVolume(ctx context.Context, req *csi.CreateVol
// Ugly, but VolumeContext isn't passed to DeleteVolume :-( // Ugly, but VolumeContext isn't passed to DeleteVolume :-(
VolumeId: string(volumeIdJson), VolumeId: string(volumeIdJson),
CapacityBytes: volSize, CapacityBytes: volSize,
ContentSource: src,
}, },
}, nil }, nil
} }
@ -291,105 +247,24 @@ func (cs *ControllerServer) DeleteVolume(ctx context.Context, req *csi.DeleteVol
return nil, status.Error(codes.InvalidArgument, "request cannot be empty") return nil, status.Error(codes.InvalidArgument, "request cannot be empty")
} }
ctxVars := make(map[string]string) volVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &ctxVars) err := json.Unmarshal([]byte(req.VolumeId), &volVars)
if (err != nil) if (err != nil)
{ {
return nil, status.Error(codes.Internal, "volume ID not in JSON format") return nil, status.Error(codes.Internal, "volume ID not in JSON format")
} }
volName := ctxVars["name"] volName := volVars["name"]
_, etcdUrl, etcdPrefix := GetConnectionParams(ctxVars) ctxVars, err := GetConnectionParams(volVars)
if (len(etcdUrl) == 0) if (err != nil)
{ {
return nil, status.Error(codes.InvalidArgument, "no etcdUrl in storage class configuration and no etcd_address in vitastor.conf") return nil, err
} }
cli, err := clientv3.New(clientv3.Config{ _, err = invokeCLI(ctxVars, []string{ "rm", volName })
DialTimeout: ETCD_TIMEOUT,
Endpoints: etcdUrl,
})
if (err != nil) if (err != nil)
{ {
return nil, status.Error(codes.Internal, "failed to connect to etcd at "+strings.Join(etcdUrl, ",")+": "+err.Error()) return nil, err
}
defer cli.Close()
// Find inode by name
ctx, cancel := context.WithTimeout(context.Background(), ETCD_TIMEOUT)
resp, err := cli.Get(ctx, etcdPrefix+"/index/image/"+volName)
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to read key from etcd: "+err.Error())
}
if (len(resp.Kvs) == 0)
{
return nil, status.Error(codes.NotFound, "volume "+volName+" does not exist")
}
var idx InodeIndex
err = json.Unmarshal(resp.Kvs[0].Value, &idx)
if (err != nil)
{
return nil, status.Error(codes.Internal, "invalid /index/image/"+volName+" key in etcd: "+err.Error())
}
// Get inode config
inodeCfgKey := fmt.Sprintf("%s/config/inode/%d/%d", etcdPrefix, idx.PoolId, idx.Id)
ctx, cancel = context.WithTimeout(context.Background(), ETCD_TIMEOUT)
resp, err = cli.Get(ctx, inodeCfgKey)
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to read key from etcd: "+err.Error())
}
if (len(resp.Kvs) == 0)
{
return nil, status.Error(codes.NotFound, "volume "+volName+" does not exist")
}
var inodeCfg InodeConfig
err = json.Unmarshal(resp.Kvs[0].Value, &inodeCfg)
if (err != nil)
{
return nil, status.Error(codes.Internal, "invalid "+inodeCfgKey+" key in etcd: "+err.Error())
}
// Delete inode data by invoking vitastor-rm
args := []string{
"--etcd_address", strings.Join(etcdUrl, ","),
"--pool", fmt.Sprintf("%d", idx.PoolId),
"--inode", fmt.Sprintf("%d", idx.Id),
}
if (ctxVars["configPath"] != "")
{
args = append(args, "--config_path", ctxVars["configPath"])
}
c := exec.Command("/usr/bin/vitastor-rm", args...)
var stderr bytes.Buffer
c.Stdout = nil
c.Stderr = &stderr
err = c.Run()
stderrStr := string(stderr.Bytes())
if (err != nil)
{
klog.Errorf("vitastor-rm failed: %s, status %s\n", stderrStr, err)
return nil, status.Error(codes.Internal, stderrStr+" (status "+err.Error()+")")
}
// Delete inode config in etcd
ctx, cancel = context.WithTimeout(context.Background(), ETCD_TIMEOUT)
txnResp, err := cli.Txn(ctx).Then(
clientv3.OpDelete(fmt.Sprintf("%s/index/image/%s", etcdPrefix, volName)),
clientv3.OpDelete(fmt.Sprintf("%s/config/inode/%d/%d", etcdPrefix, idx.PoolId, idx.Id)),
).Commit()
cancel()
if (err != nil)
{
return nil, status.Error(codes.Internal, "failed to delete keys in etcd: "+err.Error())
}
if (!txnResp.Succeeded)
{
return nil, status.Error(codes.Internal, "failed to delete keys in etcd: transaction failed")
} }
return &csi.DeleteVolumeResponse{}, nil return &csi.DeleteVolumeResponse{}, nil
@ -490,6 +365,8 @@ func (cs *ControllerServer) ControllerGetCapabilities(ctx context.Context, req *
csi.ControllerServiceCapability_RPC_LIST_VOLUMES, csi.ControllerServiceCapability_RPC_LIST_VOLUMES,
csi.ControllerServiceCapability_RPC_EXPAND_VOLUME, csi.ControllerServiceCapability_RPC_EXPAND_VOLUME,
csi.ControllerServiceCapability_RPC_CREATE_DELETE_SNAPSHOT, csi.ControllerServiceCapability_RPC_CREATE_DELETE_SNAPSHOT,
csi.ControllerServiceCapability_RPC_LIST_SNAPSHOTS,
// TODO: csi.ControllerServiceCapability_RPC_CLONE_VOLUME,
} { } {
controllerServerCapabilities = append(controllerServerCapabilities, functionControllerServerCapabilities(capability)) controllerServerCapabilities = append(controllerServerCapabilities, functionControllerServerCapabilities(capability))
} }
@ -499,28 +376,226 @@ func (cs *ControllerServer) ControllerGetCapabilities(ctx context.Context, req *
}, nil }, nil
} }
func invokeList(ctxVars map[string]string, pattern string, expectExist bool) ([]InodeConfig, error)
{
stat, err := invokeCLI(ctxVars, []string{ "ls", "--json", pattern })
if (err != nil)
{
return nil, err
}
var inodeCfg []InodeConfig
err = json.Unmarshal(stat, &inodeCfg)
if (err != nil)
{
return nil, status.Error(codes.Internal, "Invalid JSON in vitastor-cli ls: "+err.Error())
}
if (expectExist && len(inodeCfg) == 0)
{
return nil, status.Error(codes.Internal, "Can't find expected image "+pattern+" via vitastor-cli ls")
}
return inodeCfg, nil
}
// CreateSnapshot create snapshot of an existing PV // CreateSnapshot create snapshot of an existing PV
func (cs *ControllerServer) CreateSnapshot(ctx context.Context, req *csi.CreateSnapshotRequest) (*csi.CreateSnapshotResponse, error) func (cs *ControllerServer) CreateSnapshot(ctx context.Context, req *csi.CreateSnapshotRequest) (*csi.CreateSnapshotResponse, error)
{ {
return nil, status.Error(codes.Unimplemented, "") klog.Infof("received controller create snapshot request %+v", protosanitizer.StripSecrets(req))
if (req == nil)
{
return nil, status.Errorf(codes.InvalidArgument, "request cannot be empty")
}
if (req.SourceVolumeId == "" || req.Name == "")
{
return nil, status.Error(codes.InvalidArgument, "source volume ID and snapshot name are required fields")
}
// snapshot name
snapName := req.Name
// req.VolumeId is an ugly json string in our case :)
ctxVars := make(map[string]string)
err := json.Unmarshal([]byte(req.SourceVolumeId), &ctxVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
volName := ctxVars["name"]
// Create image using vitastor-cli
_, err = invokeCLI(ctxVars, []string{ "create", "--snapshot", snapName, volName })
if (err != nil && strings.Index(err.Error(), "already exists") <= 0)
{
return nil, err
}
// Check created snapshot
inodeCfg, err := invokeList(ctxVars, volName+"@"+snapName, true)
if (err != nil)
{
return nil, err
}
// Use ugly JSON snapshot ID again, DeleteSnapshot doesn't have context :-(
ctxVars["snapshot"] = snapName
snapIdJson, _ := json.Marshal(ctxVars)
return &csi.CreateSnapshotResponse{
Snapshot: &csi.Snapshot{
SizeBytes: int64(inodeCfg[0].Size),
SnapshotId: string(snapIdJson),
SourceVolumeId: req.SourceVolumeId,
CreationTime: &timestamppb.Timestamp{ Seconds: int64(inodeCfg[0].CreateTs) },
ReadyToUse: true,
},
}, nil
} }
// DeleteSnapshot delete provided snapshot of a PV // DeleteSnapshot delete provided snapshot of a PV
func (cs *ControllerServer) DeleteSnapshot(ctx context.Context, req *csi.DeleteSnapshotRequest) (*csi.DeleteSnapshotResponse, error) func (cs *ControllerServer) DeleteSnapshot(ctx context.Context, req *csi.DeleteSnapshotRequest) (*csi.DeleteSnapshotResponse, error)
{ {
return nil, status.Error(codes.Unimplemented, "") klog.Infof("received controller delete snapshot request %+v", protosanitizer.StripSecrets(req))
if (req == nil)
{
return nil, status.Errorf(codes.InvalidArgument, "request cannot be empty")
}
if (req.SnapshotId == "")
{
return nil, status.Error(codes.InvalidArgument, "snapshot ID is a required field")
}
volVars := make(map[string]string)
err := json.Unmarshal([]byte(req.SnapshotId), &volVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "snapshot ID not in JSON format")
}
volName := volVars["name"]
snapName := volVars["snapshot"]
ctxVars, err := GetConnectionParams(volVars)
if (err != nil)
{
return nil, err
}
_, err = invokeCLI(ctxVars, []string{ "rm", volName+"@"+snapName })
if (err != nil)
{
return nil, err
}
return &csi.DeleteSnapshotResponse{}, nil
} }
// ListSnapshots list the snapshots of a PV // ListSnapshots list the snapshots of a PV
func (cs *ControllerServer) ListSnapshots(ctx context.Context, req *csi.ListSnapshotsRequest) (*csi.ListSnapshotsResponse, error) func (cs *ControllerServer) ListSnapshots(ctx context.Context, req *csi.ListSnapshotsRequest) (*csi.ListSnapshotsResponse, error)
{ {
return nil, status.Error(codes.Unimplemented, "") klog.Infof("received controller list snapshots request %+v", protosanitizer.StripSecrets(req))
if (req == nil)
{
return nil, status.Error(codes.InvalidArgument, "request cannot be empty")
}
volVars := make(map[string]string)
err := json.Unmarshal([]byte(req.SourceVolumeId), &volVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
volName := volVars["name"]
ctxVars, err := GetConnectionParams(volVars)
if (err != nil)
{
return nil, err
}
inodeCfg, err := invokeList(ctxVars, volName+"@*", false)
if (err != nil)
{
return nil, err
}
resp := &csi.ListSnapshotsResponse{}
for _, ino := range inodeCfg
{
snapName := ino.Name[len(volName)+1:]
if (len(req.StartingToken) > 0 && snapName < req.StartingToken)
{
}
else if (req.MaxEntries == 0 || len(resp.Entries) < int(req.MaxEntries))
{
volVars["snapshot"] = snapName
snapIdJson, _ := json.Marshal(volVars)
resp.Entries = append(resp.Entries, &csi.ListSnapshotsResponse_Entry{
Snapshot: &csi.Snapshot{
SizeBytes: int64(ino.Size),
SnapshotId: string(snapIdJson),
SourceVolumeId: req.SourceVolumeId,
CreationTime: &timestamppb.Timestamp{ Seconds: int64(ino.CreateTs) },
ReadyToUse: true,
},
})
}
else
{
resp.NextToken = snapName
break
}
}
return resp, nil
} }
// ControllerExpandVolume resizes a volume // ControllerExpandVolume increases the size of a volume
func (cs *ControllerServer) ControllerExpandVolume(ctx context.Context, req *csi.ControllerExpandVolumeRequest) (*csi.ControllerExpandVolumeResponse, error) func (cs *ControllerServer) ControllerExpandVolume(ctx context.Context, req *csi.ControllerExpandVolumeRequest) (*csi.ControllerExpandVolumeResponse, error)
{ {
return nil, status.Error(codes.Unimplemented, "") klog.Infof("received controller expand volume request %+v", protosanitizer.StripSecrets(req))
if (req == nil)
{
return nil, status.Error(codes.InvalidArgument, "request cannot be empty")
}
if (req.VolumeId == "" || req.CapacityRange == nil || req.CapacityRange.RequiredBytes == 0)
{
return nil, status.Error(codes.InvalidArgument, "VolumeId, CapacityRange and RequiredBytes are required fields")
}
volVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &volVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
volName := volVars["name"]
ctxVars, err := GetConnectionParams(volVars)
if (err != nil)
{
return nil, err
}
inodeCfg, err := invokeList(ctxVars, volName, true)
if (err != nil)
{
return nil, err
}
if (req.CapacityRange.RequiredBytes > 0 && inodeCfg[0].Size < uint64(req.CapacityRange.RequiredBytes))
{
sz := ((req.CapacityRange.RequiredBytes+4095)/4096)*4096
_, err := invokeCLI(ctxVars, []string{ "modify", "--inc_size", "1", "--resize", fmt.Sprintf("%d", sz), volName })
if (err != nil)
{
return nil, err
}
inodeCfg, err = invokeList(ctxVars, volName, true)
if (err != nil)
{
return nil, err
}
}
return &csi.ControllerExpandVolumeResponse{
CapacityBytes: int64(inodeCfg[0].Size),
NodeExpansionRequired: false,
}, nil
} }
// ControllerGetVolume get volume info // ControllerGetVolume get volume info

View File

@ -49,6 +49,13 @@ func (is *IdentityServer) GetPluginCapabilities(ctx context.Context, req *csi.Ge
}, },
}, },
}, },
{
Type: &csi.PluginCapability_VolumeExpansion_{
VolumeExpansion: &csi.PluginCapability_VolumeExpansion{
Type: csi.PluginCapability_VolumeExpansion_OFFLINE,
},
},
},
}, },
}, nil }, nil
} }

View File

@ -5,11 +5,15 @@ package vitastor
import ( import (
"context" "context"
"encoding/json"
"fmt"
"os" "os"
"os/exec" "os/exec"
"encoding/json" "path/filepath"
"strings" "strings"
"bytes" "sync"
"syscall"
"time"
"google.golang.org/grpc/codes" "google.golang.org/grpc/codes"
"google.golang.org/grpc/status" "google.golang.org/grpc/status"
@ -25,71 +29,349 @@ import (
type NodeServer struct type NodeServer struct
{ {
*Driver *Driver
useVduse bool
stateDir string
mounter mount.Interface mounter mount.Interface
restartInterval time.Duration
mu sync.Mutex
cond *sync.Cond
volumeLocks map[string]bool
}
type DeviceState struct
{
ConfigPath string `json:"configPath"`
VdpaId string `json:"vdpaId"`
Image string `json:"image"`
Blockdev string `json:"blockdev"`
Readonly bool `json:"readonly"`
PidFile string `json:"pidFile"`
} }
// NewNodeServer create new instance node // NewNodeServer create new instance node
func NewNodeServer(driver *Driver) *NodeServer func NewNodeServer(driver *Driver) *NodeServer
{ {
return &NodeServer{ stateDir := os.Getenv("STATE_DIR")
if (stateDir == "")
{
stateDir = "/run/vitastor-csi"
}
if (stateDir[len(stateDir)-1] != '/')
{
stateDir += "/"
}
ns := &NodeServer{
Driver: driver, Driver: driver,
useVduse: checkVduseSupport(),
stateDir: stateDir,
mounter: mount.New(""), mounter: mount.New(""),
volumeLocks: make(map[string]bool),
}
ns.cond = sync.NewCond(&ns.mu)
if (ns.useVduse)
{
ns.restoreVduseDaemons()
dur, err := time.ParseDuration(os.Getenv("RESTART_INTERVAL"))
if (err != nil)
{
dur = 10 * time.Second
}
ns.restartInterval = dur
if (ns.restartInterval != time.Duration(0))
{
go ns.restarter()
}
}
return ns
}
func (ns *NodeServer) lockVolume(lockId string)
{
ns.mu.Lock()
defer ns.mu.Unlock()
for (ns.volumeLocks[lockId])
{
ns.cond.Wait()
}
ns.volumeLocks[lockId] = true
ns.cond.Broadcast()
}
func (ns *NodeServer) unlockVolume(lockId string)
{
ns.mu.Lock()
defer ns.mu.Unlock()
delete(ns.volumeLocks, lockId)
ns.cond.Broadcast()
}
func (ns *NodeServer) restarter()
{
// Restart dead VDUSE daemons at regular intervals
// Otherwise volume I/O may hang in case of a qemu-storage-daemon crash
// Moreover, it may lead to a kernel panic of the kernel is configured to
// panic on hung tasks
ticker := time.NewTicker(ns.restartInterval)
defer ticker.Stop()
for
{
<-ticker.C
ns.restoreVduseDaemons()
}
}
func (ns *NodeServer) restoreVduseDaemons()
{
pattern := ns.stateDir+"vitastor-vduse-*.json"
matches, err := filepath.Glob(pattern)
if (err != nil)
{
klog.Errorf("failed to list %s: %v", pattern, err)
}
if (len(matches) == 0)
{
return
}
devList := make(map[string]interface{})
// example output: {"dev":{"test1":{"type":"block","mgmtdev":"vduse","vendor_id":0,"max_vqs":16,"max_vq_size":128}}}
devListJSON, _, err := system("/sbin/vdpa", "-j", "dev", "list")
if (err != nil)
{
return
}
err = json.Unmarshal(devListJSON, &devList)
devs, ok := devList["dev"].(map[string]interface{})
if (err != nil || !ok)
{
klog.Errorf("/sbin/vdpa -j dev list returned bad JSON (error %v): %v", err, string(devListJSON))
return
}
for _, stateFile := range matches
{
vdpaId := filepath.Base(stateFile)
vdpaId = vdpaId[0:len(vdpaId)-5]
// Check if VDPA device is still added to the bus
if (devs[vdpaId] == nil)
{
// Unused, clean it up
unmapVduseById(ns.stateDir, vdpaId)
continue
}
stateJSON, err := os.ReadFile(stateFile)
if (err != nil)
{
klog.Warningf("error reading state file %v: %v", stateFile, err)
continue
}
var state DeviceState
err = json.Unmarshal(stateJSON, &state)
if (err != nil)
{
klog.Warningf("state file %v contains invalid JSON (error %v): %v", stateFile, err, string(stateJSON))
continue
}
ns.lockVolume(state.ConfigPath+":"+state.Image)
// Recheck state file after locking
_, err = os.ReadFile(stateFile)
if (err != nil)
{
klog.Warningf("state file %v disappeared, skipping volume", stateFile)
ns.unlockVolume(state.ConfigPath+":"+state.Image)
continue
}
// Check if the storage daemon is still active
pidFile := ns.stateDir + vdpaId + ".pid"
exists := false
proc, err := findByPidFile(pidFile)
if (err == nil)
{
exists = proc.Signal(syscall.Signal(0)) == nil
}
if (!exists)
{
// Restart daemon
klog.Warningf("restarting storage daemon for volume %v (VDPA ID %v)", state.Image, vdpaId)
_ = startStorageDaemon(vdpaId, state.Image, pidFile, state.ConfigPath, state.Readonly)
}
ns.unlockVolume(state.ConfigPath+":"+state.Image)
} }
} }
// NodeStageVolume mounts the volume to a staging path on the node. // NodeStageVolume mounts the volume to a staging path on the node.
func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVolumeRequest) (*csi.NodeStageVolumeResponse, error) func (ns *NodeServer) NodeStageVolume(ctx context.Context, req *csi.NodeStageVolumeRequest) (*csi.NodeStageVolumeResponse, error)
{ {
klog.Infof("received node stage volume request %+v", protosanitizer.StripSecrets(req))
ctxVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &ctxVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
_, err = GetConnectionParams(ctxVars)
if (err != nil)
{
return nil, err
}
volName := ctxVars["name"]
ns.lockVolume(ctxVars["configPath"]+":"+volName)
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
targetPath := req.GetStagingTargetPath()
isBlock := req.GetVolumeCapability().GetBlock() != nil
// Check that it's not already mounted
_, err = mount.IsNotMountPoint(ns.mounter, targetPath)
if (err != nil)
{
if (os.IsNotExist(err))
{
if (isBlock)
{
pathFile, err := os.OpenFile(targetPath, os.O_CREATE|os.O_RDWR, 0o600)
if (err != nil)
{
klog.Errorf("failed to create block device mount target %s with error: %v", targetPath, err)
return nil, err
}
err = pathFile.Close()
if (err != nil)
{
klog.Errorf("failed to close %s with error: %v", targetPath, err)
return nil, err
}
}
else
{
err := os.MkdirAll(targetPath, 0777)
if (err != nil)
{
klog.Errorf("failed to create fs mount target %s with error: %v", targetPath, err)
return nil, err
}
}
}
else
{
return nil, err
}
}
var devicePath, vdpaId string
if (!ns.useVduse)
{
devicePath, err = mapNbd(volName, ctxVars, false)
}
else
{
devicePath, vdpaId, err = mapVduse(ns.stateDir, volName, ctxVars, false)
}
if (err != nil)
{
return nil, err
}
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
if (isBlock)
{
err = diskMounter.Mount(devicePath, targetPath, "", []string{"bind"})
}
else
{
// Check existing format
existingFormat, err := diskMounter.GetDiskFormat(devicePath)
if (err != nil)
{
klog.Errorf("failed to get disk format for path %s, error: %v", err)
goto unmap
}
// Format the device (ext4 or xfs)
fsType := req.GetVolumeCapability().GetMount().GetFsType()
opt := req.GetVolumeCapability().GetMount().GetMountFlags()
opt = append(opt, "_netdev")
if ((req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_MULTI_NODE_READER_ONLY ||
req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_SINGLE_NODE_READER_ONLY) &&
!Contains(opt, "ro"))
{
opt = append(opt, "ro")
}
if (fsType == "xfs")
{
opt = append(opt, "nouuid")
}
readOnly := Contains(opt, "ro")
if (existingFormat == "" && !readOnly)
{
var cmdOut []byte
switch fsType
{
case "ext4":
args := []string{"-m0", "-Enodiscard,lazy_itable_init=1,lazy_journal_init=1", devicePath}
cmdOut, err = diskMounter.Exec.Command("mkfs.ext4", args...).CombinedOutput()
case "xfs":
cmdOut, err = diskMounter.Exec.Command("mkfs.xfs", "-K", devicePath).CombinedOutput()
}
if (err != nil)
{
klog.Errorf("failed to run mkfs error: %v, output: %v", err, string(cmdOut))
goto unmap
}
}
err = diskMounter.FormatAndMount(devicePath, targetPath, fsType, opt)
// Try to run online resize on mount.
// FIXME: Implement online resize. It requires online resize support in vitastor-nbd.
if (err == nil && existingFormat != "" && !readOnly)
{
var cmdOut []byte
switch (fsType)
{
case "ext4":
cmdOut, err = diskMounter.Exec.Command("resize2fs", devicePath).CombinedOutput()
case "xfs":
cmdOut, err = diskMounter.Exec.Command("xfs_growfs", devicePath).CombinedOutput()
}
if (err != nil)
{
klog.Errorf("failed to run resizefs error: %v, output: %v", err, string(cmdOut))
goto unmap
}
}
}
if (err != nil)
{
klog.Errorf(
"failed to mount device path (%s) to path (%s) for volume (%s) error: %s",
devicePath, targetPath, volName, err,
)
goto unmap
}
return &csi.NodeStageVolumeResponse{}, nil return &csi.NodeStageVolumeResponse{}, nil
unmap:
if (!ns.useVduse || len(devicePath) >= 8 && devicePath[0:8] == "/dev/nbd")
{
unmapNbd(devicePath)
}
else
{
unmapVduseById(ns.stateDir, vdpaId)
}
return nil, err
} }
// NodeUnstageVolume unstages the volume from the staging path // NodeUnstageVolume unstages the volume from the staging path
func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstageVolumeRequest) (*csi.NodeUnstageVolumeResponse, error) func (ns *NodeServer) NodeUnstageVolume(ctx context.Context, req *csi.NodeUnstageVolumeRequest) (*csi.NodeUnstageVolumeResponse, error)
{ {
return &csi.NodeUnstageVolumeResponse{}, nil klog.Infof("received node unstage volume request %+v", protosanitizer.StripSecrets(req))
}
func Contains(list []string, s string) bool
{
for i := 0; i < len(list); i++
{
if (list[i] == s)
{
return true
}
}
return false
}
// NodePublishVolume mounts the volume mounted to the staging path to the target path
func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublishVolumeRequest) (*csi.NodePublishVolumeResponse, error)
{
klog.Infof("received node publish volume request %+v", protosanitizer.StripSecrets(req))
targetPath := req.GetTargetPath()
// Check that it's not already mounted
free, error := mount.IsNotMountPoint(ns.mounter, targetPath)
if (error != nil)
{
if (os.IsNotExist(error))
{
error := os.MkdirAll(targetPath, 0777)
if (error != nil)
{
return nil, status.Error(codes.Internal, error.Error())
}
free = true
}
else
{
return nil, status.Error(codes.Internal, error.Error())
}
}
if (!free)
{
return &csi.NodePublishVolumeResponse{}, nil
}
ctxVars := make(map[string]string) ctxVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &ctxVars) err := json.Unmarshal([]byte(req.VolumeId), &ctxVars)
@ -99,127 +381,10 @@ func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublis
} }
volName := ctxVars["name"] volName := ctxVars["name"]
_, etcdUrl, etcdPrefix := GetConnectionParams(ctxVars) ns.lockVolume(ctxVars["configPath"]+":"+volName)
if (len(etcdUrl) == 0) defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
{
return nil, status.Error(codes.InvalidArgument, "no etcdUrl in storage class configuration and no etcd_address in vitastor.conf")
}
// Map NBD device targetPath := req.GetStagingTargetPath()
// FIXME: Check if already mapped
args := []string{
"map", "--etcd_address", strings.Join(etcdUrl, ","),
"--etcd_prefix", etcdPrefix,
"--image", volName,
};
if (ctxVars["configPath"] != "")
{
args = append(args, "--config_path", ctxVars["configPath"])
}
if (req.GetReadonly())
{
args = append(args, "--readonly", "1")
}
c := exec.Command("/usr/bin/vitastor-nbd", args...)
var stdout, stderr bytes.Buffer
c.Stdout, c.Stderr = &stdout, &stderr
err = c.Run()
stdoutStr, stderrStr := string(stdout.Bytes()), string(stderr.Bytes())
if (err != nil)
{
klog.Errorf("vitastor-nbd map failed: %s, status %s\n", stdoutStr+stderrStr, err)
return nil, status.Error(codes.Internal, stdoutStr+stderrStr+" (status "+err.Error()+")")
}
devicePath := strings.TrimSpace(stdoutStr)
// Check existing format
diskMounter := &mount.SafeFormatAndMount{Interface: ns.mounter, Exec: utilexec.New()}
existingFormat, err := diskMounter.GetDiskFormat(devicePath)
if (err != nil)
{
klog.Errorf("failed to get disk format for path %s, error: %v", err)
// unmap NBD device
unmapOut, unmapErr := exec.Command("/usr/bin/vitastor-nbd", "unmap", devicePath).CombinedOutput()
if (unmapErr != nil)
{
klog.Errorf("failed to unmap NBD device %s: %s, error: %v", devicePath, unmapOut, unmapErr)
}
return nil, err
}
// Format the device (ext4 or xfs)
fsType := req.GetVolumeCapability().GetMount().GetFsType()
isBlock := req.GetVolumeCapability().GetBlock() != nil
opt := req.GetVolumeCapability().GetMount().GetMountFlags()
opt = append(opt, "_netdev")
if ((req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_MULTI_NODE_READER_ONLY ||
req.VolumeCapability.AccessMode.Mode == csi.VolumeCapability_AccessMode_SINGLE_NODE_READER_ONLY) &&
!Contains(opt, "ro"))
{
opt = append(opt, "ro")
}
if (fsType == "xfs")
{
opt = append(opt, "nouuid")
}
readOnly := Contains(opt, "ro")
if (existingFormat == "" && !readOnly)
{
args := []string{}
switch fsType
{
case "ext4":
args = []string{"-m0", "-Enodiscard,lazy_itable_init=1,lazy_journal_init=1", devicePath}
case "xfs":
args = []string{"-K", devicePath}
}
if (len(args) > 0)
{
cmdOut, cmdErr := diskMounter.Exec.Command("mkfs."+fsType, args...).CombinedOutput()
if (cmdErr != nil)
{
klog.Errorf("failed to run mkfs error: %v, output: %v", cmdErr, string(cmdOut))
// unmap NBD device
unmapOut, unmapErr := exec.Command("/usr/bin/vitastor-nbd", "unmap", devicePath).CombinedOutput()
if (unmapErr != nil)
{
klog.Errorf("failed to unmap NBD device %s: %s, error: %v", devicePath, unmapOut, unmapErr)
}
return nil, status.Error(codes.Internal, cmdErr.Error())
}
}
}
if (isBlock)
{
opt = append(opt, "bind")
err = diskMounter.Mount(devicePath, targetPath, fsType, opt)
}
else
{
err = diskMounter.FormatAndMount(devicePath, targetPath, fsType, opt)
}
if (err != nil)
{
klog.Errorf(
"failed to mount device path (%s) to path (%s) for volume (%s) error: %s",
devicePath, targetPath, volName, err,
)
// unmap NBD device
unmapOut, unmapErr := exec.Command("/usr/bin/vitastor-nbd", "unmap", devicePath).CombinedOutput()
if (unmapErr != nil)
{
klog.Errorf("failed to unmap NBD device %s: %s, error: %v", devicePath, unmapOut, unmapErr)
}
return nil, status.Error(codes.Internal, err.Error())
}
return &csi.NodePublishVolumeResponse{}, nil
}
// NodeUnpublishVolume unmounts the volume from the target path
func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpublishVolumeRequest) (*csi.NodeUnpublishVolumeResponse, error)
{
klog.Infof("received node unpublish volume request %+v", protosanitizer.StripSecrets(req))
targetPath := req.GetTargetPath()
devicePath, refCount, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath) devicePath, refCount, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
if (err != nil) if (err != nil)
{ {
@ -227,27 +392,167 @@ func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpu
{ {
return nil, status.Error(codes.NotFound, "Target path not found") return nil, status.Error(codes.NotFound, "Target path not found")
} }
return nil, status.Error(codes.Internal, err.Error()) return nil, err
} }
if (devicePath == "") if (devicePath == "")
{ {
return nil, status.Error(codes.NotFound, "Volume not mounted") // volume not mounted
klog.Warningf("%s is not a mountpoint, deleting", targetPath)
os.Remove(targetPath)
return &csi.NodeUnstageVolumeResponse{}, nil
} }
// unmount // unmount
err = mount.CleanupMountPoint(targetPath, ns.mounter, false) err = mount.CleanupMountPoint(targetPath, ns.mounter, false)
if (err != nil) if (err != nil)
{ {
return nil, status.Error(codes.Internal, err.Error()) return nil, err
} }
// unmap NBD device
// unmap device
if (refCount == 1) if (refCount == 1)
{ {
unmapOut, unmapErr := exec.Command("/usr/bin/vitastor-nbd", "unmap", devicePath).CombinedOutput() if (!ns.useVduse)
if (unmapErr != nil)
{ {
klog.Errorf("failed to unmap NBD device %s: %s, error: %v", devicePath, unmapOut, unmapErr) unmapNbd(devicePath)
}
else
{
unmapVduse(ns.stateDir, devicePath)
} }
} }
return &csi.NodeUnstageVolumeResponse{}, nil
}
// NodePublishVolume mounts the volume mounted to the staging path to the target path
func (ns *NodeServer) NodePublishVolume(ctx context.Context, req *csi.NodePublishVolumeRequest) (*csi.NodePublishVolumeResponse, error)
{
klog.Infof("received node publish volume request %+v", protosanitizer.StripSecrets(req))
ctxVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &ctxVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
_, err = GetConnectionParams(ctxVars)
if (err != nil)
{
return nil, err
}
volName := ctxVars["name"]
ns.lockVolume(ctxVars["configPath"]+":"+volName)
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
stagingTargetPath := req.GetStagingTargetPath()
targetPath := req.GetTargetPath()
isBlock := req.GetVolumeCapability().GetBlock() != nil
// Check that stagingTargetPath is mounted
_, err = mount.IsNotMountPoint(ns.mounter, stagingTargetPath)
if (err != nil)
{
klog.Errorf("staging path %v is not mounted: %v", stagingTargetPath, err)
return nil, fmt.Errorf("staging path %v is not mounted: %v", stagingTargetPath, err)
}
// Check that targetPath is not already mounted
_, err = mount.IsNotMountPoint(ns.mounter, targetPath)
if (err != nil)
{
if (os.IsNotExist(err))
{
if (isBlock)
{
pathFile, err := os.OpenFile(targetPath, os.O_CREATE|os.O_RDWR, 0o600)
if (err != nil)
{
klog.Errorf("failed to create block device mount target %s with error: %v", targetPath, err)
return nil, err
}
err = pathFile.Close()
if (err != nil)
{
klog.Errorf("failed to close %s with error: %v", targetPath, err)
return nil, err
}
}
else
{
err := os.MkdirAll(targetPath, 0777)
if (err != nil)
{
klog.Errorf("failed to create fs mount target %s with error: %v", targetPath, err)
return nil, err
}
}
}
else
{
return nil, err
}
}
execArgs := []string{"--bind", stagingTargetPath, targetPath}
if (req.GetReadonly())
{
execArgs = append(execArgs, "-o", "ro")
}
cmd := exec.Command("mount", execArgs...)
cmd.Stderr = os.Stderr
klog.Infof("binding volume %v (%v) from %v to %v", volName, ctxVars["configPath"], stagingTargetPath, targetPath)
out, err := cmd.Output()
if (err != nil)
{
return nil, fmt.Errorf("Error running mount %v: %s", strings.Join(execArgs, " "), out)
}
return &csi.NodePublishVolumeResponse{}, nil
}
// NodeUnpublishVolume unmounts the volume from the target path
func (ns *NodeServer) NodeUnpublishVolume(ctx context.Context, req *csi.NodeUnpublishVolumeRequest) (*csi.NodeUnpublishVolumeResponse, error)
{
klog.Infof("received node unpublish volume request %+v", protosanitizer.StripSecrets(req))
ctxVars := make(map[string]string)
err := json.Unmarshal([]byte(req.VolumeId), &ctxVars)
if (err != nil)
{
return nil, status.Error(codes.Internal, "volume ID not in JSON format")
}
volName := ctxVars["name"]
ns.lockVolume(ctxVars["configPath"]+":"+volName)
defer ns.unlockVolume(ctxVars["configPath"]+":"+volName)
targetPath := req.GetTargetPath()
devicePath, _, err := mount.GetDeviceNameFromMount(ns.mounter, targetPath)
if (err != nil)
{
if (os.IsNotExist(err))
{
return nil, status.Error(codes.NotFound, "Target path not found")
}
return nil, err
}
if (devicePath == "")
{
// volume not mounted
klog.Warningf("%s is not a mountpoint, deleting", targetPath)
os.Remove(targetPath)
return &csi.NodeUnpublishVolumeResponse{}, nil
}
// unmount
err = mount.CleanupMountPoint(targetPath, ns.mounter, false)
if (err != nil)
{
return nil, err
}
return &csi.NodeUnpublishVolumeResponse{}, nil return &csi.NodeUnpublishVolumeResponse{}, nil
} }
@ -266,7 +571,17 @@ func (ns *NodeServer) NodeExpandVolume(ctx context.Context, req *csi.NodeExpandV
// NodeGetCapabilities returns the supported capabilities of the node server // NodeGetCapabilities returns the supported capabilities of the node server
func (ns *NodeServer) NodeGetCapabilities(ctx context.Context, req *csi.NodeGetCapabilitiesRequest) (*csi.NodeGetCapabilitiesResponse, error) func (ns *NodeServer) NodeGetCapabilities(ctx context.Context, req *csi.NodeGetCapabilitiesRequest) (*csi.NodeGetCapabilitiesResponse, error)
{ {
return &csi.NodeGetCapabilitiesResponse{}, nil return &csi.NodeGetCapabilitiesResponse{
Capabilities: []*csi.NodeServiceCapability{
&csi.NodeServiceCapability{
Type: &csi.NodeServiceCapability_Rpc{
Rpc: &csi.NodeServiceCapability_RPC{
Type: csi.NodeServiceCapability_RPC_STAGE_UNSTAGE_VOLUME,
},
},
},
},
}, nil
} }
// NodeGetInfo returns NodeGetInfoResponse for CO. // NodeGetInfo returns NodeGetInfoResponse for CO.

301
csi/src/utils.go Normal file
View File

@ -0,0 +1,301 @@
// Copyright (c) Vitaliy Filippov, 2019+
// License: VNPL-1.1 or GNU GPL-2.0+ (see README.md for details)
package vitastor
import (
"errors"
"encoding/json"
"fmt"
"os"
"os/exec"
"path/filepath"
"strconv"
"strings"
"syscall"
"k8s.io/klog"
)
func Contains(list []string, s string) bool
{
for i := 0; i < len(list); i++
{
if (list[i] == s)
{
return true
}
}
return false
}
func checkVduseSupport() bool
{
// Check VDUSE support (vdpa, vduse, virtio-vdpa kernel modules)
vduse := true
for _, mod := range []string{"vdpa", "vduse", "virtio-vdpa"}
{
_, err := os.Stat("/sys/module/"+mod)
if (err != nil)
{
if (!errors.Is(err, os.ErrNotExist))
{
klog.Errorf("failed to check /sys/module/%s: %v", mod, err)
}
c := exec.Command("/sbin/modprobe", mod)
c.Stdout = os.Stderr
c.Stderr = os.Stderr
err := c.Run()
if (err != nil)
{
klog.Errorf("/sbin/modprobe %s failed: %v", mod, err)
vduse = false
break
}
}
}
// Check that vdpa tool functions
if (vduse)
{
c := exec.Command("/sbin/vdpa", "-j", "dev")
c.Stderr = os.Stderr
err := c.Run()
if (err != nil)
{
klog.Errorf("/sbin/vdpa -j dev failed: %v", err)
vduse = false
}
}
if (!vduse)
{
klog.Errorf(
"Your host apparently has no VDUSE support. VDUSE support disabled, NBD will be used to map devices."+
" For VDUSE you need at least Linux 5.15 and the following kernel modules: vdpa, virtio-vdpa, vduse.",
)
}
return vduse
}
func mapNbd(volName string, ctxVars map[string]string, readonly bool) (string, error)
{
// Map NBD device
// FIXME: Check if already mapped
args := []string{
"map", "--image", volName,
}
if (ctxVars["configPath"] != "")
{
args = append(args, "--config_path", ctxVars["configPath"])
}
if (readonly)
{
args = append(args, "--readonly", "1")
}
stdout, stderr, err := system("/usr/bin/vitastor-nbd", args...)
dev := strings.TrimSpace(string(stdout))
if (dev == "")
{
return "", fmt.Errorf("vitastor-nbd did not return the name of NBD device. output: %s", stderr)
}
return dev, err
}
func unmapNbd(devicePath string)
{
// unmap NBD device
unmapOut, unmapErr := exec.Command("/usr/bin/vitastor-nbd", "unmap", devicePath).CombinedOutput()
if (unmapErr != nil)
{
klog.Errorf("failed to unmap NBD device %s: %s, error: %v", devicePath, unmapOut, unmapErr)
}
}
func findByPidFile(pidFile string) (*os.Process, error)
{
pidBuf, err := os.ReadFile(pidFile)
if (err != nil)
{
return nil, err
}
pid, err := strconv.ParseInt(strings.TrimSpace(string(pidBuf)), 0, 64)
if (err != nil)
{
return nil, err
}
proc, err := os.FindProcess(int(pid))
if (err != nil)
{
return nil, err
}
return proc, nil
}
func killByPidFile(pidFile string) error
{
klog.Infof("killing process with PID from file %s", pidFile)
proc, err := findByPidFile(pidFile)
if (err != nil)
{
return err
}
return proc.Signal(syscall.SIGTERM)
}
func startStorageDaemon(vdpaId, volName, pidFile, configPath string, readonly bool) error
{
// Start qemu-storage-daemon
blockSpec := map[string]interface{}{
"node-name": "disk1",
"driver": "vitastor",
"image": volName,
"cache": map[string]bool{
"direct": true,
"no-flush": false,
},
"discard": "unmap",
}
if (configPath != "")
{
blockSpec["config-path"] = configPath
}
blockSpecJson, _ := json.Marshal(blockSpec)
writable := "true"
if (readonly)
{
writable = "false"
}
_, _, err := system(
"/usr/bin/qemu-storage-daemon", "--daemonize", "--pidfile", pidFile, "--blockdev", string(blockSpecJson),
"--export", "vduse-blk,id="+vdpaId+",node-name=disk1,name="+vdpaId+",num-queues=16,queue-size=128,writable="+writable,
)
return err
}
func mapVduse(stateDir string, volName string, ctxVars map[string]string, readonly bool) (string, string, error)
{
// Generate state file
stateFd, err := os.CreateTemp(stateDir, "vitastor-vduse-*.json")
if (err != nil)
{
return "", "", err
}
stateFile := stateFd.Name()
stateFd.Close()
vdpaId := filepath.Base(stateFile)
vdpaId = vdpaId[0:len(vdpaId)-5] // remove ".json"
pidFile := stateDir + vdpaId + ".pid"
// Map VDUSE device via qemu-storage-daemon
err = startStorageDaemon(vdpaId, volName, pidFile, ctxVars["configPath"], readonly)
if (err == nil)
{
// Add device to VDPA bus
_, _, err = system("/sbin/vdpa", "-j", "dev", "add", "name", vdpaId, "mgmtdev", "vduse")
if (err == nil)
{
// Find block device name
var matches []string
matches, err = filepath.Glob("/sys/bus/vdpa/devices/"+vdpaId+"/virtio*/block/*")
if (err == nil && len(matches) == 0)
{
err = errors.New("/sys/bus/vdpa/devices/"+vdpaId+"/virtio*/block/* is not found")
}
if (err == nil)
{
blockdev := "/dev/"+filepath.Base(matches[0])
_, err = os.Stat(blockdev)
if (err == nil)
{
// Generate state file
stateJSON, _ := json.Marshal(&DeviceState{
ConfigPath: ctxVars["configPath"],
VdpaId: vdpaId,
Image: volName,
Blockdev: blockdev,
Readonly: readonly,
PidFile: pidFile,
})
err = os.WriteFile(stateFile, stateJSON, 0600)
if (err == nil)
{
return blockdev, vdpaId, nil
}
}
}
}
killErr := killByPidFile(pidFile)
if (killErr != nil)
{
klog.Errorf("Failed to kill started qemu-storage-daemon: %v", killErr)
}
os.Remove(stateFile)
os.Remove(pidFile)
}
return "", "", err
}
func unmapVduse(stateDir, devicePath string)
{
if (len(devicePath) < 6 || devicePath[0:6] != "/dev/v")
{
klog.Errorf("%s does not start with /dev/v", devicePath)
return
}
vduseDev, err := os.Readlink("/sys/block/"+devicePath[5:])
if (err != nil)
{
klog.Errorf("%s is not a symbolic link to VDUSE device (../devices/virtual/vduse/xxx): %v", devicePath, err)
return
}
vdpaId := ""
p := strings.Index(vduseDev, "/vduse/")
if (p >= 0)
{
vduseDev = vduseDev[p+7:]
p = strings.Index(vduseDev, "/")
if (p >= 0)
{
vdpaId = vduseDev[0:p]
}
}
if (vdpaId == "")
{
klog.Errorf("%s is not a symbolic link to VDUSE device (../devices/virtual/vduse/xxx), but is %v", devicePath, vduseDev)
return
}
unmapVduseById(stateDir, vdpaId)
}
func unmapVduseById(stateDir, vdpaId string)
{
_, err := os.Stat("/sys/bus/vdpa/devices/"+vdpaId)
if (err != nil)
{
klog.Errorf("failed to stat /sys/bus/vdpa/devices/"+vdpaId+": %v", err)
}
else
{
_, _, _ = system("/sbin/vdpa", "-j", "dev", "del", vdpaId)
}
stateFile := stateDir + vdpaId + ".json"
os.Remove(stateFile)
pidFile := stateDir + vdpaId + ".pid"
_, err = os.Stat(pidFile)
if (os.IsNotExist(err))
{
// ok, already killed
}
else if (err != nil)
{
klog.Errorf("Failed to stat %v: %v", pidFile, err)
return
}
else
{
err = killByPidFile(pidFile)
if (err != nil)
{
klog.Errorf("Failed to kill started qemu-storage-daemon: %v", err)
}
os.Remove(pidFile)
}
}

58
debian/build-pve-qemu.sh vendored Normal file
View File

@ -0,0 +1,58 @@
exit
git clone https://git.yourcmc.ru/vitalif/pve-qemu .
# bookworm
docker run -it -v `pwd`/pve-qemu:/root/pve-qemu --name pve-qemu-bullseye debian:bullseye bash
perl -i -pe 's/Types: deb$/Types: deb deb-src/' /etc/apt/sources.list.d/debian.sources
echo 'deb [arch=amd64] http://download.proxmox.com/debian/pve bookworm pve-no-subscription' >> /etc/apt/sources.list
echo 'deb https://vitastor.io/debian bookworm main' >> /etc/apt/sources.list
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf
echo 'ru_RU UTF-8' >> /etc/locale.gen
echo 'en_US UTF-8' >> /etc/locale.gen
apt-get update
apt-get install wget ca-certificates
wget https://enterprise.proxmox.com/debian/proxmox-release-bookworm.gpg -O /etc/apt/trusted.gpg.d/proxmox-release-bookworm.gpg
wget https://vitastor.io/debian/pubkey.gpg -O /etc/apt/trusted.gpg.d/vitastor.gpg
apt-get update
apt-get install git devscripts equivs wget mc libjemalloc-dev vitastor-client-dev lintian locales
mk-build-deps --install ./control
# bullseye
docker run -it -v `pwd`/pve-qemu:/root/pve-qemu --name pve-qemu-bullseye debian:bullseye bash
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb /deb-src /' >> /etc/apt/sources.list
echo 'deb [arch=amd64] http://download.proxmox.com/debian/pve bullseye pve-no-subscription' >> /etc/apt/sources.list
echo 'deb https://vitastor.io/debian bullseye main' >> /etc/apt/sources.list
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf
echo 'ru_RU UTF-8' >> /etc/locale.gen
echo 'en_US UTF-8' >> /etc/locale.gen
apt-get update
apt-get install wget
wget https://enterprise.proxmox.com/debian/proxmox-release-bullseye.gpg -O /etc/apt/trusted.gpg.d/proxmox-release-bullseye.gpg
wget https://vitastor.io/debian/pubkey.gpg -O /etc/apt/trusted.gpg.d/vitastor.gpg
apt-get update
apt-get install git devscripts equivs wget mc libjemalloc-dev vitastor-client-dev lintian locales
mk-build-deps --install ./control
# buster
docker run -it -v `pwd`/pve-qemu:/root/pve-qemu --name pve-qemu-buster debian:buster bash
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb /deb-src /' >> /etc/apt/sources.list
echo 'deb [arch=amd64] http://download.proxmox.com/debian/pve buster pve-no-subscription' >> /etc/apt/sources.list
echo 'deb https://vitastor.io/debian buster main' >> /etc/apt/sources.list
echo 'deb http://deb.debian.org/debian buster-backports main' >> /etc/apt/sources.list
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf
echo 'ru_RU UTF-8' >> /etc/locale.gen
echo 'en_US UTF-8' >> /etc/locale.gen
apt-get update
apt-get install wget ca-certificates
wget http://download.proxmox.com/debian/proxmox-ve-release-6.x.gpg -O /etc/apt/trusted.gpg.d/proxmox-ve-release-6.x.gpg
wget https://vitastor.io/debian/pubkey.gpg -O /etc/apt/trusted.gpg.d/vitastor.gpg
apt-get update
apt-get install git devscripts equivs wget mc libjemalloc-dev vitastor-client-dev lintian locales
mk-build-deps --install ./control

7
debian/build-vitastor-bookworm.sh vendored Executable file
View File

@ -0,0 +1,7 @@
#!/bin/bash
cat < vitastor.Dockerfile > ../Dockerfile
cd ..
mkdir -p packages
sudo podman build --build-arg DISTRO=debian --build-arg REL=bookworm -v `pwd`/packages:/root/packages -f Dockerfile .
rm Dockerfile

View File

@ -1,7 +1,7 @@
#!/bin/bash #!/bin/bash
sed 's/$REL/bullseye/g' < vitastor.Dockerfile > ../Dockerfile cat < vitastor.Dockerfile > ../Dockerfile
cd .. cd ..
mkdir -p packages mkdir -p packages
sudo podman build -v `pwd`/packages:/root/packages -f Dockerfile . sudo podman build --build-arg DISTRO=debian --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f Dockerfile .
rm Dockerfile rm Dockerfile

View File

@ -1,7 +1,7 @@
#!/bin/bash #!/bin/bash
sed 's/$REL/buster/g' < vitastor.Dockerfile > ../Dockerfile cat < vitastor.Dockerfile > ../Dockerfile
cd .. cd ..
mkdir -p packages mkdir -p packages
sudo podman build -v `pwd`/packages:/root/packages -f Dockerfile . sudo podman build --build-arg DISTRO=debian --build-arg REL=buster -v `pwd`/packages:/root/packages -f Dockerfile .
rm Dockerfile rm Dockerfile

7
debian/build-vitastor-ubuntu-jammy.sh vendored Executable file
View File

@ -0,0 +1,7 @@
#!/bin/bash
cat < vitastor.Dockerfile > ../Dockerfile
cd ..
mkdir -p packages
sudo podman build --build-arg DISTRO=ubuntu --build-arg REL=jammy -v `pwd`/packages:/root/packages -f Dockerfile .
rm Dockerfile

16
debian/changelog vendored
View File

@ -1,4 +1,18 @@
vitastor (0.6.4-1) unstable; urgency=medium vitastor (1.6.1-1) unstable; urgency=medium
* Bugfixes
-- Vitaliy Filippov <vitalif@yourcmc.ru> Fri, 03 Jun 2022 02:09:44 +0300
vitastor (0.7.0-1) unstable; urgency=medium
* Implement NFS proxy
* Add documentation
* Bugfixes
-- Vitaliy Filippov <vitalif@yourcmc.ru> Sun, 29 May 2022 23:39:13 +0300
vitastor (0.6.3-1) unstable; urgency=medium
* RDMA support * RDMA support
* Bugfixes * Bugfixes

42
debian/control vendored
View File

@ -2,16 +2,54 @@ Source: vitastor
Section: admin Section: admin
Priority: optional Priority: optional
Maintainer: Vitaliy Filippov <vitalif@yourcmc.ru> Maintainer: Vitaliy Filippov <vitalif@yourcmc.ru>
Build-Depends: debhelper, liburing-dev (>= 0.6), g++ (>= 8), libstdc++6 (>= 8), linux-libc-dev, libgoogle-perftools-dev, libjerasure-dev, libgf-complete-dev, libibverbs-dev Build-Depends: debhelper, liburing-dev (>= 0.6), g++ (>= 8), libstdc++6 (>= 8), linux-libc-dev, libgoogle-perftools-dev, libjerasure-dev, libgf-complete-dev, libibverbs-dev, libisal-dev, cmake, pkg-config, libnl-3-dev, libnl-genl-3-dev
Standards-Version: 4.5.0 Standards-Version: 4.5.0
Homepage: https://vitastor.io/ Homepage: https://vitastor.io/
Rules-Requires-Root: no Rules-Requires-Root: no
Package: vitastor Package: vitastor
Architecture: amd64 Architecture: amd64
Depends: ${shlibs:Depends}, ${misc:Depends}, fio (= ${dep:fio}), qemu (= ${dep:qemu}), nodejs (>= 10), node-sprintf-js, node-ws (>= 7), libjerasure2, lp-solve Depends: vitastor-osd, vitastor-mon, vitastor-client, vitastor-client-dev, vitastor-fio
Description: Vitastor, a fast software-defined clustered block storage Description: Vitastor, a fast software-defined clustered block storage
Vitastor is a small, simple and fast clustered block storage (storage for VM drives), Vitastor is a small, simple and fast clustered block storage (storage for VM drives),
architecturally similar to Ceph which means strong consistency, primary-replication, architecturally similar to Ceph which means strong consistency, primary-replication,
symmetric clustering and automatic data distribution over any number of drives of any symmetric clustering and automatic data distribution over any number of drives of any
size with configurable redundancy (replication or erasure codes/XOR). size with configurable redundancy (replication or erasure codes/XOR).
Package: vitastor-osd
Architecture: amd64
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client (= ${binary:Version}), fdisk, util-linux, parted
Description: Vitastor, a fast software-defined clustered block storage - object storage daemon
Vitastor object storage daemon, i.e. server program that stores data.
Package: vitastor-mon
Architecture: amd64
Depends: ${misc:Depends}, nodejs (>= 10), node-sprintf-js, node-ws (>= 7), lp-solve
Description: Vitastor, a fast software-defined clustered block storage - monitor
Vitastor monitor, i.e. server program responsible for watching cluster state and
scheduling cluster-level operations.
Package: vitastor-client
Architecture: amd64
Depends: ${shlibs:Depends}, ${misc:Depends}
Description: Vitastor, a fast software-defined clustered block storage - client
Vitastor client library and command-line interface.
Package: vitastor-client-dev
Section: devel
Architecture: amd64
Depends: ${misc:Depends}, vitastor-client (= ${binary:Version})
Description: Vitastor, a fast software-defined clustered block storage - development files
Vitastor library headers for development.
Package: vitastor-fio
Architecture: amd64
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client (= ${binary:Version}), fio (= ${dep:fio})
Description: Vitastor, a fast software-defined clustered block storage - fio drivers
Vitastor fio drivers for benchmarking.
Package: pve-storage-vitastor
Architecture: amd64
Depends: ${shlibs:Depends}, ${misc:Depends}, vitastor-client (= ${binary:Version})
Description: Vitastor Proxmox Virtual Environment storage plugin
Vitastor storage plugin for Proxmox Virtual Environment.

1
debian/fio_version vendored Normal file
View File

@ -0,0 +1 @@
dep:fio=3.16-1

3
debian/install vendored
View File

@ -1,3 +1,4 @@
VNPL-1.1.txt usr/share/doc/vitastor VNPL-1.1.txt usr/share/doc/vitastor
GPL-2.0.txt usr/share/doc/vitastor GPL-2.0.txt usr/share/doc/vitastor
mon usr/lib/vitastor README.md usr/share/doc/vitastor
README-ru.md usr/share/doc/vitastor

11
debian/libisal.pc vendored Normal file
View File

@ -0,0 +1,11 @@
prefix=/usr
exec_prefix=${prefix}
libdir=${prefix}/lib/x86_64-linux-gnu
includedir=${prefix}/include
Name: libisal
Description: Library for storage systems
Version: 2.30.0
Libs: -L${libdir} -lisal
Libs.private:
Cflags: -I${includedir}

41
debian/libvirt.Dockerfile vendored Normal file
View File

@ -0,0 +1,41 @@
# Build patched libvirt for Debian Buster or Bullseye/Sid inside a container
# cd ..; podman build --build-arg DISTRO=debian --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f debian/libvirt.Dockerfile .
ARG DISTRO=
ARG REL=
FROM $DISTRO:$REL
ARG REL=
WORKDIR /root
RUN if ([ "${DISTRO}" = "debian" ]) && ( [ "${REL}" = "buster" -o "${REL}" = "bullseye" ] ); then \
echo "deb http://deb.debian.org/debian $REL-backports main" >> /etc/apt/sources.list; \
echo >> /etc/apt/preferences; \
echo 'Package: *' >> /etc/apt/preferences; \
echo "Pin: release a=$REL-backports" >> /etc/apt/preferences; \
echo 'Pin-Priority: 500' >> /etc/apt/preferences; \
fi; \
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
RUN apt-get update; apt-get -y install devscripts
RUN apt-get -y build-dep libvirt0
RUN apt-get -y install libglusterfs-dev
RUN apt-get --download-only source libvirt
ADD patches/libvirt-5.0-vitastor.diff patches/libvirt-7.0-vitastor.diff patches/libvirt-7.5-vitastor.diff patches/libvirt-7.6-vitastor.diff patches/libvirt-8.0-vitastor.diff /root
RUN set -e; \
mkdir -p /root/packages/libvirt-$REL; \
rm -rf /root/packages/libvirt-$REL/*; \
cd /root/packages/libvirt-$REL; \
dpkg-source -x /root/libvirt*.dsc; \
D=$(ls -d libvirt-*/); \
V=$(ls -d libvirt-*/ | perl -pe 's/libvirt-(\d+\.\d+).*/$1/'); \
cp /root/libvirt-$V-vitastor.diff $D/debian/patches; \
echo libvirt-$V-vitastor.diff >> $D/debian/patches/series; \
cd $D; \
V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)(~bpo[\d\+]*)?(\+deb[u\d]+)?\).*$/$1/')+vitastor2; \
DEBEMAIL="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v $V 'Add Vitastor support'; \
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \
rm -rf /root/packages/libvirt-$REL/$D

View File

@ -1,44 +1,61 @@
# Build patched QEMU for Debian Buster or Bullseye/Sid inside a container # Build patched QEMU for Debian inside a container
# cd ..; podman build --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f debian/patched-qemu.Dockerfile . # cd ..; podman build --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f debian/patched-qemu.Dockerfile .
ARG REL=
FROM debian:$REL FROM debian:$REL
ARG REL=
WORKDIR /root WORKDIR /root
RUN if [ "$REL" = "buster" ]; then \ RUN if [ "$REL" = "buster" -o "$REL" = "bullseye" -o "$REL" = "bookworm" ]; then \
echo 'deb http://deb.debian.org/debian buster-backports main' >> /etc/apt/sources.list; \ echo "deb http://deb.debian.org/debian $REL-backports main" >> /etc/apt/sources.list; \
echo >> /etc/apt/preferences; \ echo >> /etc/apt/preferences; \
echo 'Package: *' >> /etc/apt/preferences; \ echo 'Package: *' >> /etc/apt/preferences; \
echo 'Pin: release a=buster-backports' >> /etc/apt/preferences; \ echo "Pin: release a=$REL-backports" >> /etc/apt/preferences; \
echo 'Pin-Priority: 500' >> /etc/apt/preferences; \ echo 'Pin-Priority: 500' >> /etc/apt/preferences; \
fi; \ fi; \
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \ grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
perl -i -pe 's/Types: deb$/Types: deb deb-src/' /etc/apt/sources.list.d/debian.sources || true; \
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \ echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
RUN apt-get update RUN apt-get update
RUN apt-get -y install qemu fio liburing1 liburing-dev libgoogle-perftools-dev devscripts RUN apt-get -y install fio liburing-dev libgoogle-perftools-dev devscripts
RUN apt-get -y build-dep qemu RUN apt-get -y build-dep qemu
RUN apt-get -y build-dep fio # To build a custom version
#RUN cp /root/packages/qemu-orig/* /root
RUN apt-get --download-only source qemu RUN apt-get --download-only source qemu
RUN apt-get --download-only source fio
ADD qemu-5.0-vitastor.patch qemu-5.1-vitastor.patch /root/vitastor/ ADD patches /root/vitastor/patches
ADD src/client/qemu_driver.c /root/qemu_driver.c
#RUN set -e; \
# apt-get install -y wget; \
# wget -q -O /etc/apt/trusted.gpg.d/vitastor.gpg https://vitastor.io/debian/pubkey.gpg; \
# (echo deb http://vitastor.io/debian $REL main > /etc/apt/sources.list.d/vitastor.list); \
# (echo "APT::Install-Recommends false;" > /etc/apt/apt.conf) && \
# apt-get update; \
# apt-get install -y vitastor-client vitastor-client-dev quilt
RUN set -e; \ RUN set -e; \
dpkg -i /root/packages/vitastor-$REL/vitastor-client_*.deb /root/packages/vitastor-$REL/vitastor-client-dev_*.deb; \
apt-get update; \
apt-get install -y quilt; \
mkdir -p /root/packages/qemu-$REL; \ mkdir -p /root/packages/qemu-$REL; \
rm -rf /root/packages/qemu-$REL/*; \ rm -rf /root/packages/qemu-$REL/*; \
cd /root/packages/qemu-$REL; \ cd /root/packages/qemu-$REL; \
dpkg-source -x /root/qemu*.dsc; \ dpkg-source -x /root/qemu*.dsc; \
if [ -d /root/packages/qemu-$REL/qemu-5.0 ]; then \ QEMU_VER=$(ls -d qemu*/ | perl -pe 's!^.*?(\d+\.\d+).*!$1!'); \
cp /root/vitastor/qemu-5.0-vitastor.patch /root/packages/qemu-$REL/qemu-5.0/debian/patches; \ D=$(ls -d qemu*/); \
echo qemu-5.0-vitastor.patch >> /root/packages/qemu-$REL/qemu-5.0/debian/patches/series; \ cp /root/vitastor/patches/qemu-$QEMU_VER-vitastor.patch ./qemu-*/debian/patches; \
else \ echo qemu-$QEMU_VER-vitastor.patch >> $D/debian/patches/series; \
cp /root/vitastor/qemu-5.1-vitastor.patch /root/packages/qemu-$REL/qemu-*/debian/patches; \
P=`ls -d /root/packages/qemu-$REL/qemu-*/debian/patches`; \
echo qemu-5.1-vitastor.patch >> $P/series; \
fi; \
cd /root/packages/qemu-$REL/qemu-*/; \ cd /root/packages/qemu-$REL/qemu-*/; \
V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)(~bpo[\d\+]*)?\).*$/$1/')+vitastor1; \ quilt push -a; \
DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v $V 'Plug Vitastor block driver'; \ quilt add block/vitastor.c; \
cp /root/qemu_driver.c block/vitastor.c; \
quilt refresh; \
V=$(head -n1 debian/changelog | perl -pe 's/5\.2\+dfsg-9/5.2+dfsg-11/; s/^.*\((.*?)(~bpo[\d\+]*)?\).*$/$1/')+vitastor4; \
if [ "$REL" = bullseye ]; then V=${V}bullseye; fi; \
DEBEMAIL="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v $V 'Plug Vitastor block driver'; \
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \ DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \
rm -rf /root/packages/qemu-$REL/qemu-*/ rm -rf /root/packages/qemu-$REL/qemu-*/

1
debian/pve-storage-vitastor.install vendored Normal file
View File

@ -0,0 +1 @@
patches/VitastorPlugin.pm usr/share/perl5/PVE/Storage/Custom/

19
debian/raw.h vendored Normal file
View File

@ -0,0 +1,19 @@
/* Removed in Linux 5.14 */
/* SPDX-License-Identifier: GPL-2.0 WITH Linux-syscall-note */
#ifndef __LINUX_RAW_H
#define __LINUX_RAW_H
#include <linux/types.h>
#define RAW_SETBIND _IO( 0xac, 0 )
#define RAW_GETBIND _IO( 0xac, 1 )
struct raw_config_request
{
int raw_minor;
__u64 block_major;
__u64 block_minor;
};
#endif /* __LINUX_RAW_H */

3
debian/rules vendored
View File

@ -5,5 +5,6 @@ export DH_VERBOSE = 1
dh $@ dh $@
override_dh_installdeb: override_dh_installdeb:
cat debian/substvars >> debian/vitastor.substvars cat debian/fio_version >> debian/vitastor-fio.substvars
[ -f debian/qemu_version ] && (cat debian/qemu_version >> debian/vitastor-qemu.substvars) || true
dh_installdeb dh_installdeb

2
debian/substvars vendored
View File

@ -1,2 +0,0 @@
dep:fio=3.16-1
dep:qemu=1:5.1+dfsg-4+vitastor1

2
debian/vitastor-client-dev.install vendored Normal file
View File

@ -0,0 +1,2 @@
usr/include
usr/lib/*/pkgconfig

8
debian/vitastor-client.install vendored Normal file
View File

@ -0,0 +1,8 @@
usr/bin/vita
usr/bin/vitastor-cli
usr/bin/vitastor-rm
usr/bin/vitastor-nbd
usr/bin/vitastor-nfs
usr/bin/vitastor-kv
usr/bin/vitastor-kv-stress
usr/lib/*/libvitastor*.so*

1
debian/vitastor-fio.install vendored Normal file
View File

@ -0,0 +1 @@
usr/lib/*/libfio*.so*

3
debian/vitastor-mon.install vendored Normal file
View File

@ -0,0 +1,3 @@
mon usr/lib/vitastor/mon
mon/scripts/make-etcd usr/lib/vitastor/mon
mon/scripts/vitastor-mon.service /lib/systemd/system

9
debian/vitastor-mon.postinst vendored Normal file
View File

@ -0,0 +1,9 @@
#!/bin/sh
set -e
if [ "$1" = "configure" ]; then
addgroup --system --quiet vitastor
adduser --system --quiet --ingroup vitastor --no-create-home --home /nonexistent vitastor
mkdir -p /etc/vitastor
fi

6
debian/vitastor-osd.install vendored Normal file
View File

@ -0,0 +1,6 @@
usr/bin/vitastor-osd
usr/bin/vitastor-disk
usr/bin/vitastor-dump-journal
mon/scripts/vitastor-osd@.service /lib/systemd/system
mon/scripts/vitastor.target /lib/systemd/system
mon/scripts/90-vitastor.rules /lib/udev/rules.d

10
debian/vitastor-osd.postinst vendored Normal file
View File

@ -0,0 +1,10 @@
#!/bin/sh
set -e
if [ "$1" = "configure" ]; then
addgroup --system --quiet vitastor
adduser --system --quiet --ingroup vitastor --no-create-home --home /nonexistent vitastor
install -o vitastor -g vitastor -d /var/log/vitastor
mkdir -p /etc/vitastor
fi

View File

@ -1,66 +1,58 @@
# Build Vitastor packages for Debian Buster or Bullseye/Sid inside a container # Build Vitastor packages for Debian inside a container
# cd ..; podman build --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f debian/vitastor.Dockerfile . # cd ..; podman build --build-arg DISTRO=debian --build-arg REL=bullseye -v `pwd`/packages:/root/packages -f debian/vitastor.Dockerfile .
FROM debian:$REL ARG DISTRO=debian
ARG REL=
FROM $DISTRO:$REL
ARG DISTRO=debian
ARG REL=
WORKDIR /root WORKDIR /root
RUN if [ "$REL" = "buster" ]; then \ RUN if [ "$REL" = "buster" -o "$REL" = "bullseye" ]; then \
echo 'deb http://deb.debian.org/debian buster-backports main' >> /etc/apt/sources.list; \ echo "deb http://deb.debian.org/debian $REL-backports main" >> /etc/apt/sources.list; \
echo >> /etc/apt/preferences; \ echo >> /etc/apt/preferences; \
echo 'Package: *' >> /etc/apt/preferences; \ echo 'Package: *' >> /etc/apt/preferences; \
echo 'Pin: release a=buster-backports' >> /etc/apt/preferences; \ echo "Pin: release a=$REL-backports" >> /etc/apt/preferences; \
echo 'Pin-Priority: 500' >> /etc/apt/preferences; \ echo 'Pin-Priority: 500' >> /etc/apt/preferences; \
fi; \ fi; \
grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \ grep '^deb ' /etc/apt/sources.list | perl -pe 's/^deb/deb-src/' >> /etc/apt/sources.list; \
perl -i -pe 's/Types: deb$/Types: deb deb-src/' /etc/apt/sources.list.d/debian.sources || true; \
echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \ echo 'APT::Install-Recommends false;' >> /etc/apt/apt.conf; \
echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf echo 'APT::Install-Suggests false;' >> /etc/apt/apt.conf
RUN apt-get update RUN apt-get update
RUN apt-get -y install qemu fio liburing1 liburing-dev libgoogle-perftools-dev devscripts RUN apt-get -y install fio liburing-dev libgoogle-perftools-dev devscripts
RUN apt-get -y build-dep qemu
RUN apt-get -y build-dep fio RUN apt-get -y build-dep fio
RUN apt-get --download-only source qemu
RUN apt-get --download-only source fio RUN apt-get --download-only source fio
RUN apt-get update && apt-get -y install libjerasure-dev cmake libibverbs-dev RUN apt-get update && apt-get -y install libjerasure-dev cmake libibverbs-dev libisal-dev libnl-3-dev libnl-genl-3-dev
ADD . /root/vitastor ADD . /root/vitastor
RUN set -e -x; \ RUN set -e -x; \
[ -e /usr/lib/x86_64-linux-gnu/pkgconfig/libisal.pc ] || cp /root/vitastor/debian/libisal.pc /usr/lib/x86_64-linux-gnu/pkgconfig; \
mkdir -p /root/fio-build/; \ mkdir -p /root/fio-build/; \
cd /root/fio-build/; \ cd /root/fio-build/; \
rm -rf /root/fio-build/*; \ rm -rf /root/fio-build/*; \
dpkg-source -x /root/fio*.dsc; \ dpkg-source -x /root/fio*.dsc; \
cd /root/packages/qemu-$REL/; \
rm -rf qemu*/; \
dpkg-source -x qemu*.dsc; \
cd /root/packages/qemu-$REL/qemu*/; \
debian/rules b/configure-stamp; \
cd b/qemu; \
make -j8 qapi/qapi-builtin-types.h; \
mkdir -p /root/packages/vitastor-$REL; \ mkdir -p /root/packages/vitastor-$REL; \
rm -rf /root/packages/vitastor-$REL/*; \ rm -rf /root/packages/vitastor-$REL/*; \
cd /root/packages/vitastor-$REL; \ cd /root/packages/vitastor-$REL; \
cp -r /root/vitastor vitastor-0.6.4; \ cp -r /root/vitastor vitastor-1.6.1; \
ln -s /root/packages/qemu-$REL/qemu-*/ vitastor-0.6.4/qemu; \ cd vitastor-1.6.1; \
ln -s /root/fio-build/fio-*/ vitastor-0.6.4/fio; \ ln -s /root/fio-build/fio-*/ ./fio; \
cd vitastor-0.6.4; \
FIO=$(head -n1 fio/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \ FIO=$(head -n1 fio/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
QEMU=$(head -n1 qemu/debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \ ls /usr/include/linux/raw.h || cp ./debian/raw.h /usr/include/linux/raw.h; \
sh copy-qemu-includes.sh; \
sh copy-fio-includes.sh; \ sh copy-fio-includes.sh; \
rm qemu fio; \ rm fio; \
mkdir -p a b debian/patches; \ mkdir -p a b debian/patches; \
mv qemu-copy b/qemu; \
mv fio-copy b/fio; \ mv fio-copy b/fio; \
diff -NaurpbB a b > debian/patches/qemu-fio-headers.patch || true; \ diff -NaurpbB a b > debian/patches/fio-headers.patch || true; \
echo qemu-fio-headers.patch >> debian/patches/series; \ echo fio-headers.patch >> debian/patches/series; \
rm -rf a b; \ rm -rf a b; \
rm -rf /root/packages/qemu-$REL/qemu*/; \ echo "dep:fio=$FIO" > debian/fio_version; \
echo "dep:fio=$FIO" > debian/substvars; \
echo "dep:qemu=$QEMU" >> debian/substvars; \
cd /root/packages/vitastor-$REL; \ cd /root/packages/vitastor-$REL; \
tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_0.6.4.orig.tar.xz vitastor-0.6.4; \ tar --sort=name --mtime='2020-01-01' --owner=0 --group=0 --exclude=debian -cJf vitastor_1.6.1.orig.tar.xz vitastor-1.6.1; \
cd vitastor-0.6.4; \ cd vitastor-1.6.1; \
V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \ V=$(head -n1 debian/changelog | perl -pe 's/^.*\((.*?)\).*$/$1/'); \
DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v "$V""$REL" "Rebuild for $REL"; \ DEBFULLNAME="Vitaliy Filippov <vitalif@yourcmc.ru>" dch -D $REL -v "$V""$REL" "Rebuild for $REL"; \
DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \ DEB_BUILD_OPTIONS=nocheck dpkg-buildpackage --jobs=auto -sa; \

9
docker/Dockerfile Normal file
View File

@ -0,0 +1,9 @@
# Build Docker image with Vitastor packages
FROM debian:bullseye
ADD vitastor.list /etc/apt/sources.list.d
ADD vitastor.gpg /etc/apt/trusted.gpg.d
ADD vitastor.pref /etc/apt/preferences.d
ADD apt.conf /etc/apt/
RUN apt-get update && apt-get -y install vitastor qemu-system-x86 qemu-system-common && apt-get clean

1
docker/apt.conf Normal file
View File

@ -0,0 +1 @@
APT::Install-Recommends false;

BIN
docker/vitastor.gpg Normal file

Binary file not shown.

1
docker/vitastor.list Normal file
View File

@ -0,0 +1 @@
deb http://vitastor.io/debian bullseye main

3
docker/vitastor.pref Normal file
View File

@ -0,0 +1,3 @@
Package: *
Pin: origin "vitastor.io"
Pin-Priority: 1000

40
docs/config.en.md Normal file
View File

@ -0,0 +1,40 @@
[Documentation](../README.md#documentation) → Configuration Reference
-----
[Читать на русском](config.ru.md)
# Configuration Reference
Vitastor configuration consists of:
- [Configuration parameters (key-value)](#parameter-reference)
- [Pool configuration](config/pool.en.md)
- [OSD placement tree configuration](config/pool.en.md#placement-tree)
- [Separate OSD settings](config/pool.en.md#osd-settings)
- [Inode configuration](config/inode.en.md) i.e. image metadata like name, size and parent reference
Configuration parameters can be set in 3 places:
- Configuration file (`/etc/vitastor/vitastor.conf` or other path)
- etcd key `/vitastor/config/global`. Most variables can be set there, but etcd
connection parameters should obviously be set in the configuration file.
- Command line of Vitastor components: OSD (when you run it without vitastor-disk),
mon, fio and QEMU options, OpenStack/Proxmox/etc configuration. The latter
doesn't allow to set all variables directly, but it allows to override the
configuration file and set everything you need inside it.
- OSD superblocks created by [vitastor-disk](usage/disk.en.md) contain
primarily disk layout parameters of specific OSDs. In fact, these parameters
are automatically passed into the command line of vitastor-osd process, so
they have the same "status" as command-line parameters.
In the future, additional configuration methods may be added:
- OSD-specific keys in etcd like `/vitastor/config/osd/<number>`.
## Parameter Reference
- [Common](config/common.en.md)
- [Network](config/network.en.md)
- [Client](config/client.en.md)
- [Global Disk Layout](config/layout-cluster.en.md)
- [OSD Disk Layout](config/layout-osd.en.md)
- [OSD Runtime Parameters](config/osd.en.md)
- [Monitor](config/monitor.en.md)

43
docs/config.ru.md Normal file
View File

@ -0,0 +1,43 @@
[Документация](../README-ru.md#документация) → Конфигурация Vitastor
-----
[Read in English](config.en.md)
# Конфигурация Vitastor
Конфигурация Vitastor состоит из:
- [Параметров (ключ-значение)](#список-параметров)
- [Настроек пулов](config/pool.ru.md)
- [Настроек дерева OSD](config/pool.ru.md#дерево-размещения)
- [Настроек отдельных OSD](config/pool.ru.md#настройки-osd)
- [Настроек инодов](config/inode.ru.md), т.е. метаданных образов, таких, как имя, размер и ссылки на
родительский образ
Параметры конфигурации могут задаваться в 3 местах:
- Файле конфигурации (`/etc/vitastor/vitastor.conf` или по другому пути)
- Ключе в etcd `/vitastor/config/global`. Большая часть параметров может
задаваться там, кроме, естественно, самих параметров соединения с etcd,
которые должны задаваться в файле конфигурации
- В командной строке компонентов Vitastor: OSD (при ручном запуске без vitastor-disk),
монитора, опциях fio и QEMU, настроек OpenStack, Proxmox и т.п. Последние,
как правило, не включают полный набор параметров напрямую, но позволяют
определить путь к файлу конфигурации и задать любые параметры в нём.
- В суперблоке OSD, записываемом [vitastor-disk](usage/disk.ru.md) - параметры,
связанные с дисковым форматом и с этим конкретным OSD. На самом деле,
при запуске OSD эти параметры автоматически передаются в командную строку
процесса vitastor-osd, то есть по "статусу" они эквивалентны параметрам
командной строки OSD.
В будущем также могут быть добавлены другие способы конфигурации:
- OSD-специфичные ключи в etcd типа `/vitastor/config/osd/<номер>`.
## Список параметров
- [Общие](config/common.ru.md)
- [Сеть](config/network.ru.md)
- [Клиентский код](config/client.ru.md)
- [Глобальные дисковые параметры](config/layout-cluster.ru.md)
- [Дисковые параметры OSD](config/layout-osd.ru.md)
- [Прочие параметры OSD](config/osd.ru.md)
- [Параметры мониторов](config/monitor.ru.md)

185
docs/config/client.en.md Normal file
View File

@ -0,0 +1,185 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Client Parameters
-----
[Читать на русском](client.ru.md)
# Client Parameters
These parameters apply only to Vitastor clients (QEMU, fio, NBD and so on) and
affect their interaction with the cluster.
- [client_retry_interval](#client_retry_interval)
- [client_eio_retry_interval](#client_eio_retry_interval)
- [client_retry_enospc](#client_retry_enospc)
- [client_max_dirty_bytes](#client_max_dirty_bytes)
- [client_max_dirty_ops](#client_max_dirty_ops)
- [client_enable_writeback](#client_enable_writeback)
- [client_max_buffered_bytes](#client_max_buffered_bytes)
- [client_max_buffered_ops](#client_max_buffered_ops)
- [client_max_writeback_iodepth](#client_max_writeback_iodepth)
- [nbd_timeout](#nbd_timeout)
- [nbd_max_devices](#nbd_max_devices)
- [nbd_max_part](#nbd_max_part)
- [osd_nearfull_ratio](#osd_nearfull_ratio)
## client_retry_interval
- Type: milliseconds
- Default: 50
- Minimum: 10
- Can be changed online: yes
Retry time for I/O requests failed due to inactive PGs or network
connectivity errors.
## client_eio_retry_interval
- Type: milliseconds
- Default: 1000
- Can be changed online: yes
Retry time for I/O requests failed due to data corruption or unfinished
EC object deletions (has_incomplete PG state). 0 disables such retries
and clients are not blocked and just get EIO error code instead.
## client_retry_enospc
- Type: boolean
- Default: true
- Can be changed online: yes
Retry writes on out of space errors to wait until some space is freed on
OSDs.
## client_max_dirty_bytes
- Type: integer
- Default: 33554432
- Can be changed online: yes
Without [immediate_commit](layout-cluster.en.md#immediate_commit)=all this parameter sets the limit of "dirty"
(not committed by fsync) data allowed by the client before forcing an
additional fsync and committing the data. Also note that the client always
holds a copy of uncommitted data in memory so this setting also affects
RAM usage of clients.
## client_max_dirty_ops
- Type: integer
- Default: 1024
- Can be changed online: yes
Same as client_max_dirty_bytes, but instead of total size, limits the number
of uncommitted write operations.
## client_enable_writeback
- Type: boolean
- Default: false
- Can be changed online: yes
This parameter enables client-side write buffering. This means that write
requests are accumulated in memory for a short time before being sent to
a Vitastor cluster which allows to send them in parallel and increase
performance of some applications. Writes are buffered until client forces
a flush with fsync() or until the amount of buffered writes exceeds the
limit.
Write buffering significantly increases performance of some applications,
for example, CrystalDiskMark under Windows (LOL :-D), but also any other
applications if they do writes in one of two non-optimal ways: either if
they do a lot of small (4 kb or so) sequential writes, or if they do a lot
of small random writes, but without any parallelism or asynchrony, and also
without calling fsync().
With write buffering enabled, you can expect around 22000 T1Q1 random write
iops in QEMU more or less regardless of the quality of your SSDs, and this
number is in fact bound by QEMU itself rather than Vitastor (check it
yourself by adding a "driver=null-co" disk in QEMU). Without write
buffering, the current record is 9900 iops, but the number is usually
even lower with non-ideal hardware, for example, it may be 5000 iops.
Even when this parameter is enabled, write buffering isn't enabled until
the client explicitly allows it, because enabling it without the client
being aware of the fact that his writes may be buffered may lead to data
loss. Because of this, older versions of clients don't support write
buffering at all, newer versions of the QEMU driver allow write buffering
only if it's enabled in disk settings with `-blockdev cache.direct=false`,
and newer versions of FIO only allow write buffering if you don't specify
`-direct=1`. NBD and NFS drivers allow write buffering by default.
You can overcome this restriction too with the `client_writeback_allowed`
parameter, but you shouldn't do that unless you **really** know what you
are doing.
## client_max_buffered_bytes
- Type: integer
- Default: 33554432
- Can be changed online: yes
Maximum total size of buffered writes which triggers write-back when reached.
## client_max_buffered_ops
- Type: integer
- Default: 1024
- Can be changed online: yes
Maximum number of buffered writes which triggers write-back when reached.
Multiple consecutive modified data regions are counted as 1 write here.
## client_max_writeback_iodepth
- Type: integer
- Default: 256
- Can be changed online: yes
Maximum number of parallel writes when flushing buffered data to the server.
## nbd_timeout
- Type: seconds
- Default: 300
Timeout for I/O operations for [NBD](../usage/nbd.en.md). If an operation
executes for longer than this timeout, including when your cluster is just
temporarily down for more than timeout, the NBD device will detach by itself
(and possibly break the mounted file system).
You can set timeout to 0 to never detach, but in that case you won't be
able to remove the kernel device at all if the NBD process dies - you'll have
to reboot the host.
## nbd_max_devices
- Type: integer
- Default: 64
Maximum number of NBD devices in the system. This value is passed as
`nbds_max` parameter for the nbd kernel module when vitastor-nbd autoloads it.
## nbd_max_part
- Type: integer
- Default: 3
Maximum number of partitions per NBD device. This value is passed as
`max_part` parameter for the nbd kernel module when vitastor-nbd autoloads it.
Note that (nbds_max)*(1+max_part) usually can't exceed 256.
## osd_nearfull_ratio
- Type: number
- Default: 0.95
- Can be changed online: yes
Ratio of used space on OSD to treat it as "almost full" in vitastor-cli status output.
Remember that some client writes may hang or complete with an error if even
just one OSD becomes 100 % full!
However, unlike in Ceph, 100 % full Vitastor OSDs don't crash (in Ceph they're
unable to start at all), so you'll be able to recover from "out of space" errors
without destroying and recreating OSDs.

188
docs/config/client.ru.md Normal file
View File

@ -0,0 +1,188 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Параметры клиентского кода
-----
[Read in English](client.en.md)
# Параметры клиентского кода
Данные параметры применяются только к клиентам Vitastor (QEMU, fio, NBD и т.п.) и
затрагивают логику их работы с кластером.
- [client_retry_interval](#client_retry_interval)
- [client_eio_retry_interval](#client_eio_retry_interval)
- [client_retry_enospc](#client_retry_enospc)
- [client_max_dirty_bytes](#client_max_dirty_bytes)
- [client_max_dirty_ops](#client_max_dirty_ops)
- [client_enable_writeback](#client_enable_writeback)
- [client_max_buffered_bytes](#client_max_buffered_bytes)
- [client_max_buffered_ops](#client_max_buffered_ops)
- [client_max_writeback_iodepth](#client_max_writeback_iodepth)
- [nbd_timeout](#nbd_timeout)
- [nbd_max_devices](#nbd_max_devices)
- [nbd_max_part](#nbd_max_part)
- [osd_nearfull_ratio](#osd_nearfull_ratio)
## client_retry_interval
- Тип: миллисекунды
- Значение по умолчанию: 50
- Минимальное значение: 10
- Можно менять на лету: да
Время повтора запросов ввода-вывода, неудачных из-за неактивных PG или
ошибок сети.
## client_eio_retry_interval
- Тип: миллисекунды
- Значение по умолчанию: 1000
- Можно менять на лету: да
Время повтора запросов ввода-вывода, неудачных из-за повреждения данных
или незавершённых удалений EC-объектов (состояния PG has_incomplete).
0 отключает повторы таких запросов и клиенты не блокируются, а вместо
этого просто получают код ошибки EIO.
## client_retry_enospc
- Тип: булево (да/нет)
- Значение по умолчанию: true
- Можно менять на лету: да
Повторять запросы записи, завершившиеся с ошибками нехватки места, т.е.
ожидать, пока на OSD не освободится место.
## client_max_dirty_bytes
- Тип: целое число
- Значение по умолчанию: 33554432
- Можно менять на лету: да
При работе без [immediate_commit](layout-cluster.ru.md#immediate_commit)=all - это лимит объёма "грязных" (не
зафиксированных fsync-ом) данных, при достижении которого клиент будет
принудительно вызывать fsync и фиксировать данные. Также стоит иметь в виду,
что в этом случае до момента fsync клиент хранит копию незафиксированных
данных в памяти, то есть, настройка влияет на потребление памяти клиентами.
## client_max_dirty_ops
- Тип: целое число
- Значение по умолчанию: 1024
- Можно менять на лету: да
Аналогично client_max_dirty_bytes, но ограничивает количество
незафиксированных операций записи вместо их общего объёма.
## client_enable_writeback
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Данный параметр разрешает включать буферизацию записи в памяти. Буферизация
означает, что операции записи отправляются на кластер Vitastor не сразу, а
могут небольшое время накапливаться в памяти и сбрасываться сразу пакетами,
до тех пор, пока либо не будет превышен лимит неотправленных записей, либо
пока клиент не вызовет fsync.
Буферизация значительно повышает производительность некоторых приложений,
например, CrystalDiskMark в Windows (ха-ха :-D), но также и любых других,
которые пишут на диск неоптимально: либо последовательно, но мелкими блоками
(например, по 4 кб), либо случайно, но без параллелизма и без fsync - то
есть, например, отправляя 128 операций записи в разные места диска, но не
все сразу с помощью асинхронного I/O, а по одной.
В QEMU с буферизацией записи можно ожидать показателя примерно 22000
операций случайной записи в секунду в 1 поток и с глубиной очереди 1 (T1Q1)
без fsync, почти вне зависимости от того, насколько хороши ваши диски - эта
цифра упирается в сам QEMU. Без буферизации рекорд пока что - 9900 операций
в секунду, но на железе похуже может быть и поменьше, например, 5000 операций
в секунду.
При этом, даже если данный параметр включён, буферизация не включается, если
явно не разрешена клиентом, т.к. если клиент не знает, что запросы записи
буферизуются, это может приводить к потере данных. Поэтому в старых версиях
клиентских драйверов буферизация записи не включается вообще, в новых
версиях QEMU-драйвера включается, только если разрешена опцией диска
`-blockdev cache.direct=false`, а в fio - только если нет опции `-direct=1`.
В NBD и NFS драйверах буферизация записи разрешена по умолчанию.
Можно обойти и это ограничение с помощью параметра `client_writeback_allowed`,
но делать так не надо, если только вы не уверены в том, что делаете, на все
100%. :-)
## client_max_buffered_bytes
- Тип: целое число
- Значение по умолчанию: 33554432
- Можно менять на лету: да
Максимальный общий размер буферизованных записей, при достижении которого
начинается процесс сброса данных на сервер.
## client_max_buffered_ops
- Тип: целое число
- Значение по умолчанию: 1024
- Можно менять на лету: да
Максимальное количество буферизованных записей, при достижении которого
начинается процесс сброса данных на сервер. При этом несколько
последовательных изменённых областей здесь считаются 1 записью.
## client_max_writeback_iodepth
- Тип: целое число
- Значение по умолчанию: 256
- Можно менять на лету: да
Максимальное число параллельных операций записи при сбросе буферов на сервер.
## nbd_timeout
- Тип: секунды
- Значение по умолчанию: 300
Таймаут для операций чтения/записи через [NBD](../usage/nbd.ru.md). Если
операция выполняется дольше таймаута, включая временную недоступность
кластера на время, большее таймаута, NBD-устройство отключится само собой
(и, возможно, сломает примонтированную ФС).
Вы можете установить таймаут в 0, чтобы никогда не отключать устройство по
таймауту, но в этом случае вы вообще не сможете удалить устройство, если
процесс NBD умрёт - вам придётся перезагружать сервер.
## nbd_max_devices
- Тип: целое число
- Значение по умолчанию: 64
Максимальное число NBD-устройств в системе. Данное значение передаётся
модулю ядра nbd как параметр `nbds_max`, когда его загружает vitastor-nbd.
## nbd_max_part
- Тип: целое число
- Значение по умолчанию: 3
Максимальное число разделов на одном NBD-устройстве. Данное значение передаётся
модулю ядра nbd как параметр `max_part`, когда его загружает vitastor-nbd.
Имейте в виду, что (nbds_max)*(1+max_part) обычно не может превышать 256.
## osd_nearfull_ratio
- Тип: число
- Значение по умолчанию: 0.95
- Можно менять на лету: да
Доля занятого места на OSD, начиная с которой он считается "почти заполненным" в
выводе vitastor-cli status.
Помните, что часть клиентских запросов может зависнуть или завершиться с ошибкой,
если на 100 % заполнится хотя бы 1 OSD!
Однако, в отличие от Ceph, заполненные на 100 % OSD Vitastor не падают (в Ceph
заполненные на 100% OSD вообще не могут стартовать), так что вы сможете
восстановить работу кластера после ошибок отсутствия свободного места
без уничтожения и пересоздания OSD.

52
docs/config/common.en.md Normal file
View File

@ -0,0 +1,52 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Common Parameters
-----
[Читать на русском](common.ru.md)
# Common Parameters
These are the most common parameters which apply to all components of Vitastor.
- [config_path](#config_path)
- [etcd_address](#etcd_address)
- [etcd_prefix](#etcd_prefix)
- [log_level](#log_level)
## config_path
- Type: string
- Default: /etc/vitastor/vitastor.conf
Path to the JSON configuration file. Configuration file is optional,
a non-existing configuration file does not prevent Vitastor from
running if required parameters are specified.
## etcd_address
- Type: string or array of strings
- Can be changed online: yes
etcd connection endpoint(s). Multiple endpoints may be delimited by "," or
specified in a JSON array `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
Note that https is not supported for etcd connections yet.
etcd connection endpoints can be changed online by updating global
configuration in etcd itself - this allows to switch the cluster to new
etcd addresses without downtime.
## etcd_prefix
- Type: string
- Default: /vitastor
Prefix for all keys in etcd used by Vitastor. You can change prefix and, for
example, use a single etcd cluster for multiple Vitastor clusters.
## log_level
- Type: integer
- Default: 0
- Can be changed online: yes
Log level. Raise if you want more verbose output.

50
docs/config/common.ru.md Normal file
View File

@ -0,0 +1,50 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Общие параметры
-----
[Read in English](common.en.md)
# Общие параметры
Это наиболее общие параметры, используемые всеми компонентами Vitastor.
- [config_path](#config_path)
- [etcd_address](#etcd_address)
- [etcd_prefix](#etcd_prefix)
- [log_level](#log_level)
## config_path
- Тип: строка
- Значение по умолчанию: /etc/vitastor/vitastor.conf
Путь к файлу конфигурации в формате JSON. Файл конфигурации необязателен,
без него Vitastor тоже будет работать, если переданы необходимые параметры.
## etcd_address
- Тип: строка или массив строк
- Можно менять на лету: да
Адрес(а) подключения к etcd. Несколько адресов могут разделяться запятой
или указываться в виде JSON-массива `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
Адреса подключения к etcd можно поменять на лету, обновив конфигурацию в
самом etcd - это позволяет переключить кластер на новые etcd без остановки.
## etcd_prefix
- Тип: строка
- Значение по умолчанию: /vitastor
Префикс для ключей etcd, которые использует Vitastor. Вы можете задать другой
префикс, например, чтобы запустить несколько кластеров Vitastor с одним
кластером etcd.
## log_level
- Тип: целое число
- Значение по умолчанию: 0
- Можно менять на лету: да
Уровень логгирования. Повысьте, если хотите более подробный вывод.

32
docs/config/inode.en.md Normal file
View File

@ -0,0 +1,32 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Image metadata in etcd
-----
[Читать на русском](inode.ru.md)
# Image metadata in etcd
Image list is stored in etcd in `/vitastor/config/inode/<pool>/<inode>` keys.
You can even create images manually:
```
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
```
For example:
```
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
```
If you specify parent_id the image becomes a CoW clone. I.e. all writes go to the new inode and reads first check it
and then upper layers. You can then make parent readonly by updating its entry with `"readonly":true` for safety and
basically treat it as a snapshot.
So to create a snapshot you basically rename the previous upper layer (for example from testimg to testimg@0), make it readonly
and create a new top layer with the original name (testimg) and the previous one as a parent.
vitastor-cli, K8s, OpenStack and other drivers also store the reverse mapping in `/vitastor/index/image/<name>` keys
in JSON format: `{"id":<inode>,"pool_id":<pool>}` and ID counters in `/vitastor/index/maxid/<pool>` as numbers
to simplify ID generation.

34
docs/config/inode.ru.md Normal file
View File

@ -0,0 +1,34 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Метаданные образов в etcd
-----
[Read in English](inode.en.md)
# Метаданные образов в etcd
Список образов хранится в etcd в ключах `/vitastor/config/inode/<pool>/<inode>`.
Вы можете даже создавать образы вручную:
```
etcdctl --endpoints=<etcd> put /vitastor/config/inode/<pool>/<inode> '{"name":"<name>","size":<size>[,"parent_id":<parent_inode_number>][,"readonly":true]}'
```
Например:
```
etcdctl --endpoints=http://10.115.0.10:2379/v3 put /vitastor/config/inode/1/1 '{"name":"testimg","size":2147483648}'
```
Если вы зададите parent_id, то образ станет CoW-клоном, т.е. все новые запросы записи пойдут в новый инод, а запросы
чтения будут проверять сначала его, а потом родительские слои по цепочке вверх. Чтобы случайно не перезаписать данные
в родительском слое, вы можете переключить его в режим "только чтение", добавив флаг `"readonly":true` в его запись
метаданных. В таком случае родительский образ становится просто снапшотом.
Таким образом, для создания снапшота вам нужно просто переименовать предыдущий inode (например, из testimg в testimg@0),
сделать его readonly и создать новый слой с исходным именем образа (testimg), ссылающийся на только что переименованный
в качестве родительского.
vitastor-cli и драйвера K8s, OpenStack и т.п. также хранят обратный маппинг в ключах `/vitastor/index/image/<name>`
в JSON-формате: `{"id":<inode>,"pool_id":<pool>}` и счётчики ID `/vitastor/index/maxid/<pool>` в виде просто чисел
для упрощения генерации ID новых образов.

View File

@ -0,0 +1,107 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Cluster-Wide Disk Layout Parameters
-----
[Читать на русском](layout-cluster.ru.md)
# Cluster-Wide Disk Layout Parameters
These parameters apply to clients and OSDs, are fixed at the moment of OSD drive
initialization and can't be changed after it without losing data.
OSDs with different values of these parameters (for example, SSD and SSD+HDD
OSDs) can coexist in one Vitastor cluster within different pools. Each pool can
only include OSDs with identical settings of these parameters.
These parameters, when set to a non-default value, must also be specified in
etcd for clients to be aware of their values, either in /vitastor/config/global
or in pool configuration. Pool configuration overrides the global setting.
If the value for a pool in etcd doesn't match on-disk OSD configuration, the
OSD will refuse to start PGs of that pool.
- [block_size](#block_size)
- [bitmap_granularity](#bitmap_granularity)
- [immediate_commit](#immediate_commit)
## block_size
- Type: integer
- Default: 131072
Size of objects (data blocks) into which all physical and virtual drives
(within a pool) are subdivided in Vitastor. One of current main settings
in Vitastor, affects memory usage, write amplification and I/O load
distribution effectiveness.
Recommended default block size is 128 KB for SSD and 1 MB for HDD. In fact,
it's possible to use 1 MB for SSD too - it will lower memory usage, but
may increase average WA and reduce linear performance.
OSD memory usage is roughly (SIZE / BLOCK * 68 bytes) which is roughly
544 MB per 1 TB of used disk space with the default 128 KB block size.
With 1 MB it's 8 times lower.
## bitmap_granularity
- Type: integer
- Default: 4096
Required virtual disk write alignment ("sector size"). Must be a multiple
of disk_alignment. It's called bitmap granularity because Vitastor tracks
an allocation bitmap for each object containing 2 bits per each
(bitmap_granularity) bytes.
Can't be smaller than the OSD data device sector.
## immediate_commit
- Type: string
- Default: false
Another parameter which is really important for performance.
Desktop SSDs are very fast (100000+ iops) for simple random writes
without cache flush. However, they are really slow (only around 1000 iops)
if you try to fsync() each write, that is, when you want to guarantee that
each change gets immediately persisted to the physical media.
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
fast with and without fsync because their cache is protected from sudden
power loss by a built-in supercapacitor-based "UPS".
Some software-defined storage systems always fsync each write and thus are
really slow when used with desktop SSDs. Vitastor, however, can also
efficiently utilize desktop SSDs by postponing fsync until the client calls
it explicitly.
This is what this parameter regulates. When it's set to "all" the whole
Vitastor cluster commits each change to disks immediately and clients just
ignore fsyncs because they know for sure that they're unneeded. This reduces
the amount of network roundtrips performed by clients and improves
performance. So it's always better to use server grade SSDs with
supercapacitors even with Vitastor, especially given that they cost only
a bit more than desktop models.
There is also a common SATA SSD (and HDD too!) firmware bug (or feature)
that makes server SSDs which have supercapacitors slow with fsync. To check
if your SSDs are affected, compare benchmark results from `fio -name=test
-ioengine=libaio -direct=1 -bs=4k -rw=randwrite -iodepth=1` with and without
`-fsync=1`. Results should be the same. If fsync=1 result is worse you can
try to work around this bug by "disabling" drive write-back cache by running
`hdparm -W 0 /dev/sdXX` or `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
(IMPORTANT: don't mistake it with `/sys/block/sdXX/queue/write_cache` - it's
unsafe to change by hand). The same may apply to newer HDDs with internal
SSD cache or "media-cache" - for example, a lot of Seagate EXOS drives have
it (they have internal SSD cache even though it's not stated in datasheets).
Setting this parameter to "all" or "small" in OSD parameters requires enabling
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
TLDR: For optimal performance, set immediate_commit to "all" if you only use
SSDs with supercapacitor-based power loss protection (nonvolatile
write-through cache) for both data and journals in the whole Vitastor
cluster. Set it to "small" if you only use such SSDs for journals. Leave
empty if your drives have write-back cache.

View File

@ -0,0 +1,115 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Дисковые параметры уровня кластера
-----
[Read in English](layout-cluster.en.md)
# Дисковые параметры уровня кластера
Данные параметры используются клиентами и OSD, задаются в момент инициализации
диска OSD и не могут быть изменены после этого без потери данных.
OSD с разными значениями данных параметров (например, SSD и гибридные SSD+HDD
OSD) могут сосуществовать в одном кластере Vitastor в разных пулах. Один пул
может включать только OSD с одинаковыми настройками этих параметров.
Данные параметры, отличаясь от значения по умолчанию, должны также быть заданы
в etcd, чтобы клиенты могли узнать их значение, либо в глобальной конфигурации
/vitastor/config/global, либо в настройках пулов. Настройки пула переопределяют
глобальное значение. Если значение в настройках пула не будет соответствовать
конфигурации OSD, OSD откажется запускать PG данного пула.
- [block_size](#block_size)
- [bitmap_granularity](#bitmap_granularity)
- [immediate_commit](#immediate_commit)
## block_size
- Тип: целое число
- Значение по умолчанию: 131072
Размер объектов (блоков данных), на которые делятся физические и виртуальные
диски в Vitastor (в рамках каждого пула). Одна из ключевых на данный момент
настроек, влияет на потребление памяти, объём избыточной записи (write
amplification) и эффективность распределения нагрузки по OSD.
Рекомендуемые по умолчанию размеры блока - 128 килобайт для SSD и 1 мегабайт
для HDD. В принципе, для SSD можно тоже использовать блок размером 1 мегабайт,
это понизит использование памяти, но ухудшит распределение нагрузки и в
среднем увеличит WA.
Потребление памяти OSD составляет примерно (РАЗМЕР / БЛОК * 68 байт),
т.е. примерно 544 МБ памяти на 1 ТБ занятого места на диске при
стандартном 128 КБ блоке. При 1 МБ блоке памяти нужно в 8 раз меньше.
## bitmap_granularity
- Тип: целое число
- Значение по умолчанию: 4096
Требуемое выравнивание записи на виртуальные диски (размер их "сектора").
Должен быть кратен disk_alignment. Называется гранулярностью битовой карты
потому, что Vitastor хранит битовую карту для каждого объекта, содержащую
по 2 бита на каждые (bitmap_granularity) байт.
Не может быть меньше размера сектора дисков данных OSD.
## immediate_commit
- Тип: строка
- Значение по умолчанию: false
Ещё один важный для производительности параметр.
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
секунду) при простой случайной записи без сбросов кэша. Однако они очень
медленные (всего порядка 1000 iops), если вы пытаетесь сбрасывать кэш после
каждой записи, то есть, если вы пытаетесь гарантировать, что каждое
изменение физически записывается в энергонезависимую память.
С другой стороны, серверные SSD с конденсаторами - функцией, называемой
"Advanced/Enhanced Power Loss Protection" или просто "Supercapacitor-based
Power Loss Protection" - одинаково быстрые и со сбросом кэша, и без
него, потому что их кэш защищён от потери питания встроенным "источником
бесперебойного питания" на основе суперконденсаторов и на самом деле они
его никогда не сбрасывают.
Некоторые программные СХД всегда сбрасывают кэши дисков при каждой записи
и поэтому работают очень медленно с настольными SSD. Vitastor, однако, может
откладывать fsync до явного его вызова со стороны клиента и таким образом
эффективно утилизировать настольные SSD.
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
использовать только серверные модели SSD с суперконденсаторами, особенно
учитывая то, что стоят они ненамного дороже настольных.
Также в прошивках SATA SSD (и даже HDD!) очень часто встречается либо баг,
либо просто особенность логики, из-за которой серверные SSD, имеющие
конденсаторы и защиту от потери питания, всё равно медленно работают с
fsync. Чтобы понять, подвержены ли этой проблеме ваши SSD, сравните
результаты тестов `fio -name=test -ioengine=libaio -direct=1 -bs=4k
-rw=randwrite -iodepth=1` без и с опцией `-fsync=1`. Результаты должны
быть одинаковые. Если результат с `fsync=1` хуже, вы можете попробовать
обойти проблему, "отключив" кэш записи диска командой `hdparm -W 0 /dev/sdXX`
либо `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
(ВАЖНО: не перепутайте с `/sys/block/sdXX/queue/write_cache` - этот параметр
менять руками небезопасно). Такая же проблема может встречаться и в новых
HDD-дисках с внутренним SSD или "медиа" кэшем - например, она встречается во
многих дисках Seagate EXOS (у них есть внутренний SSD-кэш, хотя это и не
указано в спецификациях).
Указание "all" или "small" в настройках / командной строке OSD требует
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
Итого, вкратце: для оптимальной производительности установите
immediate_commit в значение "all", если вы используете в кластере только SSD
с суперконденсаторами и для данных, и для журналов. Если вы используете
такие SSD для всех журналов, но не для данных - можете установить параметр
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
оставьте параметр пустым.

View File

@ -0,0 +1,218 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → OSD Disk Layout Parameters
-----
[Читать на русском](layout-osd.ru.md)
# OSD Disk Layout Parameters
These parameters apply to OSDs, are fixed at the moment of OSD drive
initialization and can't be changed after it without losing data.
- [data_device](#data_device)
- [meta_device](#meta_device)
- [journal_device](#journal_device)
- [journal_offset](#journal_offset)
- [journal_size](#journal_size)
- [meta_offset](#meta_offset)
- [data_offset](#data_offset)
- [data_size](#data_size)
- [meta_block_size](#meta_block_size)
- [journal_block_size](#journal_block_size)
- [disable_data_fsync](#disable_data_fsync)
- [disable_meta_fsync](#disable_meta_fsync)
- [disable_journal_fsync](#disable_journal_fsync)
- [disable_device_lock](#disable_device_lock)
- [disk_alignment](#disk_alignment)
- [data_csum_type](#data_csum_type)
- [csum_block_size](#csum_block_size)
## data_device
- Type: string
Path to the block device to use for data. It's highly recommendded to use
stable paths for all device names: `/dev/disk/by-partuuid/xxx...` instead
of just `/dev/sda` or `/dev/nvme0n1` to not mess up after server restart.
Files can also be used instead of block devices, but this is implemented
only for testing purposes and not for production.
## meta_device
- Type: string
Path to the block device to use for the metadata. Metadata must be on a fast
SSD or performance will suffer. If this option is skipped, `data_device` is
used for the metadata.
## journal_device
- Type: string
Path to the block device to use for the journal. Journal must be on a fast
SSD or performance will suffer. If this option is skipped, `meta_device` is
used for the journal, and if it's also empty, journal is put on
`data_device`. It's almost always fine to put metadata and journal on the
same device, in this case you only need to set `meta_device`.
## journal_offset
- Type: integer
- Default: 0
Offset on the device in bytes where the journal is stored.
## journal_size
- Type: integer
Journal size in bytes. By default, all available space between journal_offset
and data_offset, meta_offset or the end of the journal device is used.
Large journals aren't needed in SSD-only setups, 32 MB is always enough.
In SSD+HDD setups it is beneficial to use larger journals (for example, 1 GB)
and enable [throttle_small_writes](osd.en.md#throttle_small_writes).
## meta_offset
- Type: integer
- Default: 0
Offset on the device in bytes where the metadata area is stored.
Again, set it to something if you colocate metadata with journal or data.
## data_offset
- Type: integer
- Default: 0
Offset on the device in bytes where the data area is stored.
Again, set it to something if you colocate data with journal or metadata.
## data_size
- Type: integer
Data area size in bytes. By default, the whole data device up to the end
will be used for the data area, but you can restrict it if you want to use
a smaller part. Note that there is no option to set metadata area size -
it's derived from the data area size.
## meta_block_size
- Type: integer
- Default: 4096
Physical block size of the metadata device. 4096 for most current
HDDs and SSDs.
## journal_block_size
- Type: integer
- Default: 4096
Physical block size of the journal device. Must be a multiple of
`disk_alignment`. 4096 for most current HDDs and SSDs.
## disable_data_fsync
- Type: boolean
- Default: false
Do not issue fsyncs to the data device, i.e. do not flush its cache.
Safe ONLY if your data device has write-through cache. If you disable
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure
that the cache disable command is run every time before starting Vitastor
OSD, for example, in the systemd unit. See also `immediate_commit` option
for the instructions to disable cache and how to benefit from it.
## disable_meta_fsync
- Type: boolean
- Default: false
Same as disable_data_fsync, but for the metadata device. If the metadata
device is not set or if the data device is used for the metadata the option
is ignored and disable_data_fsync value is used instead of it.
## disable_journal_fsync
- Type: boolean
- Default: false
Same as disable_data_fsync, but for the journal device. If the journal
device is not set or if the metadata device is used for the journal the
option is ignored and disable_meta_fsync value is used instead of it. If
the same device is used for data, metadata and journal the option is also
ignored and disable_data_fsync value is used instead of it.
## disable_device_lock
- Type: boolean
- Default: false
Do not lock data, metadata and journal block devices exclusively with
flock(). Though it's not recommended, but you can use it you want to run
multiple OSD with a single device and different offsets, without using
partitions.
## disk_alignment
- Type: integer
- Default: 4096
Required physical disk write alignment. Most current SSD and HDD drives
use 4 KB physical sectors even if they report 512 byte logical sector
size, so 4 KB is a good default setting.
Note, however, that physical sector size also affects WA, because with block
devices it's impossible to write anything smaller than a block. So, when
Vitastor has to write a single metadata entry that's only about 32 bytes in
size, it actually has to write the whole 4 KB sector.
Because of this it can actually be beneficial to use SSDs which work well
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
and meta_block_size. But the only SSD that may fit into this category is
Intel Optane (probably, not tested yet).
Clients don't need to be aware of disk_alignment, so it's not required to
put a modified value into etcd key /vitastor/config/global.
## data_csum_type
- Type: string
- Default: none
Data checksum type to use. May be "crc32c" or "none". Set to "crc32c" to
enable data checksums.
## csum_block_size
- Type: integer
- Default: 4096
Checksum calculation block size.
Must be equal or a multiple of [bitmap_granularity](layout-cluster.en.md#bitmap_granularity)
(which is usually 4 KB).
Checksums increase metadata size by 4 bytes per each csum_block_size of data.
Checksums are always a tradeoff:
1. You either sacrifice +1 GB RAM per 1 TB of data
2. Or you raise csum_block_size, for example, to 32k and sacrifice
50% random write iops due to checksum read-modify-write
3. Or you turn off [inmemory_metadata](osd.en.md#inmemory_metadata) and
sacrifice 50% random read iops due to checksum reads
All-flash clusters usually have enough RAM to use default csum_block_size,
which uses 1 GB RAM per 1 TB of data. HDD clusters usually don't.
Thus, recommended setups are:
1. All-flash, 1 GB RAM per 1 TB data: default (csum_block_size=4k)
2. All-flash, less RAM: csum_block_size=4k + inmemory_metadata=false
3. Hybrid HDD+SSD: csum_block_size=4k + inmemory_metadata=false
4. HDD-only, faster random read: csum_block_size=32k
5. HDD-only, faster random write: csum_block_size=4k +
inmemory_metadata=false + meta_io=cached
See also [meta_io](osd.en.md#meta_io).

View File

@ -0,0 +1,231 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Дисковые параметры OSD
-----
[Read in English](layout-osd.en.md)
# Дисковые параметры OSD
Данные параметры используются только OSD и, также как и общекластерные
дисковые параметры, задаются в момент инициализации дисков OSD и не могут быть
изменены после этого без потери данных.
- [data_device](#data_device)
- [meta_device](#meta_device)
- [journal_device](#journal_device)
- [journal_offset](#journal_offset)
- [journal_size](#journal_size)
- [meta_offset](#meta_offset)
- [data_offset](#data_offset)
- [data_size](#data_size)
- [meta_block_size](#meta_block_size)
- [journal_block_size](#journal_block_size)
- [disable_data_fsync](#disable_data_fsync)
- [disable_meta_fsync](#disable_meta_fsync)
- [disable_journal_fsync](#disable_journal_fsync)
- [disable_device_lock](#disable_device_lock)
- [disk_alignment](#disk_alignment)
- [data_csum_type](#data_csum_type)
- [csum_block_size](#csum_block_size)
## data_device
- Тип: строка
Путь к диску (блочному устройству) для хранения данных. Крайне рекомендуется
использовать стабильные пути: `/dev/disk/by-partuuid/xxx...` вместо простых
`/dev/sda` или `/dev/nvme0n1`, чтобы пути не могли спутаться после
перезагрузки сервера. Также вместо блочных устройств можно указывать файлы,
но это реализовано только для тестирования, а не для боевой среды.
## meta_device
- Тип: строка
Путь к диску метаданных. Метаданные должны располагаться на быстром
SSD-диске, иначе производительность пострадает. Если эта опция не указана,
для метаданных используется `data_device`.
## journal_device
- Тип: строка
Путь к диску журнала. Журнал должен располагаться на быстром SSD-диске,
иначе производительность пострадает. Если эта опция не указана,
для журнала используется `meta_device`, если же пуста и она, журнал
располагается на `data_device`. Нормально располагать журнал и метаданные
на одном устройстве, в этом случае достаточно указать только `meta_device`.
## journal_offset
- Тип: целое число
- Значение по умолчанию: 0
Смещение на устройстве в байтах, по которому располагается журнал.
## journal_size
- Тип: целое число
Размер журнала в байтах. По умолчанию для журнала используется всё доступное
место между journal_offset и data_offset, meta_offset или концом диска.
В SSD-кластерах большие журналы не нужны, достаточно 32 МБ. В гибридных
(SSD+HDD) кластерах осмысленно использовать больший размер журнал (например, 1 ГБ)
и включить [throttle_small_writes](osd.ru.md#throttle_small_writes).
## meta_offset
- Тип: целое число
- Значение по умолчанию: 0
Смещение на устройстве в байтах, по которому располагаются метаданные.
Эту опцию нужно задать, если метаданные у вас хранятся на том же
устройстве, что данные или журнал.
## data_offset
- Тип: целое число
- Значение по умолчанию: 0
Смещение на устройстве в байтах, по которому располагаются данные.
Эту опцию нужно задать, если данные у вас хранятся на том же
устройстве, что метаданные или журнал.
## data_size
- Тип: целое число
Размер области данных в байтах. По умолчанию под данные будет использована
вся доступная область устройства данных до конца устройства, но вы можете
использовать эту опцию, чтобы ограничить её меньшим размером. Заметьте, что
опции размера области метаданных нет - она вычисляется из размера области
данных автоматически.
## meta_block_size
- Тип: целое число
- Значение по умолчанию: 4096
Размер физического блока устройства метаданных. 4096 для большинства
современных SSD и HDD.
## journal_block_size
- Тип: целое число
- Значение по умолчанию: 4096
Размер физического блока устройства журнала. Должен быть кратен
`disk_alignment`. 4096 для большинства современных SSD и HDD.
## disable_data_fsync
- Тип: булево (да/нет)
- Значение по умолчанию: false
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш.
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
записью (write-through). Если вы отключаете кэш через `hdparm` или
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е.
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша
и о том, как из этого извлечь выгоду.
## disable_meta_fsync
- Тип: булево (да/нет)
- Значение по умолчанию: false
То же, что disable_data_fsync, но для устройства метаданных. Если устройство
метаданных не задано или если оно равно устройству данных, значение опции
игнорируется и вместо него используется значение опции disable_data_fsync.
## disable_journal_fsync
- Тип: булево (да/нет)
- Значение по умолчанию: false
То же, что disable_data_fsync, но для устройства журнала. Если устройство
журнала не задано или если оно равно устройству метаданных, значение опции
игнорируется и вместо него используется значение опции disable_meta_fsync.
Если одно и то же устройство используется и под данные, и под журнал, и под
метаданные - значение опции также игнорируется и вместо него используется
значение опции disable_data_fsync.
## disable_device_lock
- Тип: булево (да/нет)
- Значение по умолчанию: false
Не блокировать устройства данных, метаданных и журнала от открытия их
другими OSD с помощью flock(). Так делать не рекомендуется, но теоретически
вы можете это использовать, чтобы запускать несколько OSD на одном
устройстве с разными смещениями и без использования разделов.
## disk_alignment
- Тип: целое число
- Значение по умолчанию: 4096
Требуемое выравнивание записи на физические диски. Почти все современные
SSD и HDD диски используют 4 КБ физические секторы, даже если показывают
логический размер сектора 512 байт, поэтому 4 КБ - хорошее значение по
умолчанию.
Однако стоит понимать, что физический размер сектора тоже влияет на
избыточную запись (WA), потому что ничего меньше блока (сектора) на блочное
устройство записать невозможно. Таким образом, когда Vitastor-у нужно
записать на диск всего лишь одну 32-байтную запись метаданных, фактически
приходится перезаписывать 4 КБ сектор целиком.
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
journal_block_size и meta_block_size. Однако единственные SSD, которые
теоретически могут попасть в эту категорию - это Intel Optane (но и это
пока не проверялось автором).
Клиентам не обязательно знать про disk_alignment, так что помещать значение
этого параметра в etcd в /vitastor/config/global не нужно.
## data_csum_type
- Тип: строка
- Значение по умолчанию: none
Тип используемых OSD контрольных сумм данных. Может быть "crc32c" или "none".
Установите в "crc32c", чтобы включить расчёт и проверку контрольных сумм данных.
Следует понимать, что контрольные суммы в зависимости от размера блока их
расчёта либо увеличивают потребление памяти, либо снижают производительность.
Подробнее смотрите в описании параметра [csum_block_size](#csum_block_size).
## csum_block_size
- Тип: целое число
- Значение по умолчанию: 4096
Размер блока расчёта контрольных сумм.
Должен быть равен или кратен [bitmap_granularity](layout-cluster.ru.md#bitmap_granularity)
(который обычно равен 4 КБ).
Контрольные суммы увеличивают размер метаданных на 4 байта на каждые
csum_block_size данных.
Контрольные суммы - это всегда компромисс:
1. Вы либо жертвуете потреблением +1 ГБ памяти на 1 ТБ дискового пространства
2. Либо вы повышаете csum_block_size до, скажем, 32k и жертвуете 50%
скорости случайной записи из-за цикла чтения-изменения-записи для расчёта
новых контрольных сумм
3. Либо вы отключаете [inmemory_metadata](osd.ru.md#inmemory_metadata) и
жертвуете 50% скорости случайного чтения из-за чтения контрольных сумм
с диска
Таким образом, рекомендуются следующие варианты настроек:
1. All-flash, 1 ГБ памяти на 1 ТБ данных: по умолчанию (csum_block_size=4k)
2. All-flash, меньше памяти: csum_block_size=4k + inmemory_metadata=false
3. Гибридные HDD+SSD: csum_block_size=4k + inmemory_metadata=false
4. Только HDD, быстрее случайное чтение: csum_block_size=32k
5. Только HDD, быстрее случайная запись: csum_block_size=4k +
inmemory_metadata=false + meta_io=cached
Смотрите также [meta_io](osd.ru.md#meta_io).

88
docs/config/monitor.en.md Normal file
View File

@ -0,0 +1,88 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Monitor Parameters
-----
[Читать на русском](monitor.ru.md)
# Monitor Parameters
These parameters only apply to Monitors.
- [etcd_mon_ttl](#etcd_mon_ttl)
- [etcd_mon_timeout](#etcd_mon_timeout)
- [etcd_mon_retries](#etcd_mon_retries)
- [mon_change_timeout](#mon_change_timeout)
- [mon_stats_timeout](#mon_stats_timeout)
- [osd_out_time](#osd_out_time)
- [placement_levels](#placement_levels)
- [use_old_pg_combinator](#use_old_pg_combinator)
## etcd_mon_ttl
- Type: seconds
- Default: 1
- Minimum: 5
Monitor etcd lease refresh interval in seconds
## etcd_mon_timeout
- Type: milliseconds
- Default: 1000
etcd request timeout used by monitor
## etcd_mon_retries
- Type: integer
- Default: 5
Maximum number of attempts for one monitor etcd request
## mon_change_timeout
- Type: milliseconds
- Default: 1000
- Minimum: 100
Optimistic retry interval for monitor etcd modification requests
## mon_stats_timeout
- Type: milliseconds
- Default: 1000
- Minimum: 100
Interval for monitor to wait before updating aggregated statistics in
etcd after receiving OSD statistics updates
## osd_out_time
- Type: seconds
- Default: 600
Time after which a failed OSD is removed from the data distribution.
I.e. time which the monitor waits before attempting to restore data
redundancy using other OSDs.
## placement_levels
- Type: json
- Default: `{"host":100,"osd":101}`
Levels for the placement tree. You can define arbitrary tree levels by
defining them in this parameter. The configuration parameter value should
contain a JSON object with level names as keys and integer priorities as
values. Smaller priority means higher level in tree. For example,
"datacenter" should have smaller priority than "osd". "host" and "osd"
levels are always predefined and can't be removed. If one of them is not
present in the configuration, then it is defined with the default priority
(100 for "host", 101 for "osd").
## use_old_pg_combinator
- Type: boolean
- Default: false
Use the old PG combination generator which doesn't support [level_placement](pool.en.md#level_placement)
and [raw_placement](pool.en.md#raw_placement) for pools which don't use this features.

89
docs/config/monitor.ru.md Normal file
View File

@ -0,0 +1,89 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Параметры мониторов
-----
[Read in English](monitor.en.md)
# Параметры мониторов
Данные параметры используются только мониторами Vitastor.
- [etcd_mon_ttl](#etcd_mon_ttl)
- [etcd_mon_timeout](#etcd_mon_timeout)
- [etcd_mon_retries](#etcd_mon_retries)
- [mon_change_timeout](#mon_change_timeout)
- [mon_stats_timeout](#mon_stats_timeout)
- [osd_out_time](#osd_out_time)
- [placement_levels](#placement_levels)
- [use_old_pg_combinator](#use_old_pg_combinator)
## etcd_mon_ttl
- Тип: секунды
- Значение по умолчанию: 1
- Минимальное значение: 5
Интервал обновления etcd резервации (lease) монитором
## etcd_mon_timeout
- Тип: миллисекунды
- Значение по умолчанию: 1000
Таймаут выполнения запросов к etcd от монитора
## etcd_mon_retries
- Тип: целое число
- Значение по умолчанию: 5
Максимальное число попыток выполнения запросов к etcd монитором
## mon_change_timeout
- Тип: миллисекунды
- Значение по умолчанию: 1000
- Минимальное значение: 100
Время повтора при коллизиях при запросах модификации в etcd, производимых монитором
## mon_stats_timeout
- Тип: миллисекунды
- Значение по умолчанию: 1000
- Минимальное значение: 100
Интервал, который монитор ожидает при изменении статистики по отдельным
OSD перед обновлением агрегированной статистики в etcd
## osd_out_time
- Тип: секунды
- Значение по умолчанию: 600
Время, через которое отключенный OSD исключается из распределения данных.
То есть, время, которое монитор ожидает перед попыткой переместить данные
на другие OSD и таким образом восстановить избыточность хранения.
## placement_levels
- Тип: json
- Значение по умолчанию: `{"host":100,"osd":101}`
Определения уровней для дерева размещения OSD. Вы можете определять
произвольные уровни, помещая их в данный параметр конфигурации. Значение
параметра должно содержать JSON-объект, ключи которого будут являться
названиями уровней, а значения - целочисленными приоритетами. Меньшие
приоритеты соответствуют верхним уровням дерева. Например, уровень
"датацентр" должен иметь меньший приоритет, чем "OSD". Уровни с названиями
"host" и "osd" являются предопределёнными и не могут быть удалены. Если
один из них отсутствует в конфигурации, он доопределяется с приоритетом по
умолчанию (100 для уровня "host", 101 для "osd").
## use_old_pg_combinator
- Тип: булево (да/нет)
- Значение по умолчанию: false
Использовать старый генератор комбинаций PG, не поддерживающий [level_placement](pool.ru.md#level_placement)
и [raw_placement](pool.ru.md#raw_placement) для пулов, которые не используют данные функции.

255
docs/config/network.en.md Normal file
View File

@ -0,0 +1,255 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Network Protocol Parameters
-----
[Читать на русском](network.ru.md)
# Network Protocol Parameters
These parameters apply to clients and OSDs and affect network connection logic
between clients, OSDs and etcd.
- [tcp_header_buffer_size](#tcp_header_buffer_size)
- [use_sync_send_recv](#use_sync_send_recv)
- [use_rdma](#use_rdma)
- [rdma_device](#rdma_device)
- [rdma_port_num](#rdma_port_num)
- [rdma_gid_index](#rdma_gid_index)
- [rdma_mtu](#rdma_mtu)
- [rdma_max_sge](#rdma_max_sge)
- [rdma_max_msg](#rdma_max_msg)
- [rdma_max_recv](#rdma_max_recv)
- [rdma_max_send](#rdma_max_send)
- [rdma_odp](#rdma_odp)
- [peer_connect_interval](#peer_connect_interval)
- [peer_connect_timeout](#peer_connect_timeout)
- [osd_idle_timeout](#osd_idle_timeout)
- [osd_ping_timeout](#osd_ping_timeout)
- [max_etcd_attempts](#max_etcd_attempts)
- [etcd_quick_timeout](#etcd_quick_timeout)
- [etcd_slow_timeout](#etcd_slow_timeout)
- [etcd_keepalive_timeout](#etcd_keepalive_timeout)
- [etcd_ws_keepalive_interval](#etcd_ws_keepalive_interval)
## tcp_header_buffer_size
- Type: integer
- Default: 65536
Size of the buffer used to read data using an additional copy. Vitastor
packet headers are 128 bytes, payload is always at least 4 KB, so it is
usually beneficial to try to read multiple packets at once even though
it requires to copy the data an additional time. The rest of each packet
is received without an additional copy. You can try to play with this
parameter and see how it affects random iops and linear bandwidth if you
want.
## use_sync_send_recv
- Type: boolean
- Default: false
If true, synchronous send/recv syscalls are used instead of io_uring for
socket communication. Useless for OSDs because they require io_uring anyway,
but may be required for clients with old kernel versions.
## use_rdma
- Type: boolean
- Default: true
Try to use RDMA for communication if it's available. Disable if you don't
want Vitastor to use RDMA. TCP-only clients can also talk to an RDMA-enabled
cluster, so disabling RDMA may be needed if clients have RDMA devices,
but they are not connected to the cluster.
## rdma_device
- Type: string
RDMA device name to use for Vitastor OSD communications (for example,
"rocep5s0f0"). Now Vitastor supports all adapters, even ones without
ODP support, like Mellanox ConnectX-3 and non-Mellanox cards.
Versions up to Vitastor 1.2.0 required ODP which is only present in
Mellanox ConnectX >= 4. See also [rdma_odp](#rdma_odp).
Run `ibv_devinfo -v` as root to list available RDMA devices and their
features.
Remember that you also have to configure your network switches if you use
RoCE/RoCEv2, otherwise you may experience unstable performance. Refer to
the manual of your network vendor for details about setting up the switch
for RoCEv2 correctly. Usually it means setting up Lossless Ethernet with
PFC (Priority Flow Control) and ECN (Explicit Congestion Notification).
## rdma_port_num
- Type: integer
- Default: 1
RDMA device port number to use. Only for devices that have more than 1 port.
See `phys_port_cnt` in `ibv_devinfo -v` output to determine how many ports
your device has.
## rdma_gid_index
- Type: integer
- Default: 0
Global address identifier index of the RDMA device to use. Different GID
indexes may correspond to different protocols like RoCEv1, RoCEv2 and iWARP.
Search for "GID" in `ibv_devinfo -v` output to determine which GID index
you need.
**IMPORTANT:** If you want to use RoCEv2 (as recommended) then the correct
rdma_gid_index is usually 1 (IPv6) or 3 (IPv4).
## rdma_mtu
- Type: integer
- Default: 4096
RDMA Path MTU to use. Must be 1024, 2048 or 4096. There is usually no
sense to change it from the default 4096.
## rdma_max_sge
- Type: integer
- Default: 128
Maximum number of scatter/gather entries to use for RDMA. OSDs negotiate
the actual value when establishing connection anyway, so it's usually not
required to change this parameter.
## rdma_max_msg
- Type: integer
- Default: 132096
Maximum size of a single RDMA send or receive operation in bytes.
## rdma_max_recv
- Type: integer
- Default: 16
Maximum number of RDMA receive buffers per connection (RDMA requires
preallocated buffers to receive data). Each buffer is `rdma_max_msg` bytes
in size. So this setting directly affects memory usage: a single Vitastor
RDMA client uses `rdma_max_recv * rdma_max_msg * OSD_COUNT` bytes of memory.
Default is roughly 2 MB * number of OSDs.
## rdma_max_send
- Type: integer
- Default: 8
Maximum number of outstanding RDMA send operations per connection. Should be
less than `rdma_max_recv` so the receiving side doesn't run out of buffers.
Doesn't affect memory usage - additional memory isn't allocated for send
operations.
## rdma_odp
- Type: boolean
- Default: false
Use RDMA with On-Demand Paging. ODP is currently only available on Mellanox
ConnectX-4 and newer adapters. ODP allows to not register memory explicitly
for RDMA adapter to be able to use it. This, in turn, allows to skip memory
copying during sending. One would think this should improve performance, but
**in reality** RDMA performance with ODP is **drastically** worse. Example
3-node cluster with 8 NVMe in each node and 2*25 GBit/s ConnectX-6 RDMA network
without ODP pushes 3950000 read iops, but only 239000 iops with ODP...
This happens because Mellanox ODP implementation seems to be based on
message retransmissions when the adapter doesn't know about the buffer yet -
it likely uses standard "RNR retransmissions" (RNR = receiver not ready)
which is generally slow in RDMA/RoCE networks. Here's a presentation about
it from ISPASS-2021 conference: https://tkygtr6.github.io/pub/ISPASS21_slides.pdf
ODP support is retained in the code just in case a good ODP implementation
appears one day.
## peer_connect_interval
- Type: seconds
- Default: 5
- Minimum: 1
- Can be changed online: yes
Interval before attempting to reconnect to an unavailable OSD.
## peer_connect_timeout
- Type: seconds
- Default: 5
- Minimum: 1
- Can be changed online: yes
Timeout for OSD connection attempts.
## osd_idle_timeout
- Type: seconds
- Default: 5
- Minimum: 1
- Can be changed online: yes
OSD connection inactivity time after which clients and other OSDs send
keepalive requests to check state of the connection.
## osd_ping_timeout
- Type: seconds
- Default: 5
- Minimum: 1
- Can be changed online: yes
Maximum time to wait for OSD keepalive responses. If an OSD doesn't respond
within this time, the connection to it is dropped and a reconnection attempt
is scheduled.
## max_etcd_attempts
- Type: integer
- Default: 5
- Can be changed online: yes
Maximum number of attempts for etcd requests which can't be retried
indefinitely.
## etcd_quick_timeout
- Type: milliseconds
- Default: 1000
- Can be changed online: yes
Timeout for etcd requests which should complete quickly, like lease refresh.
## etcd_slow_timeout
- Type: milliseconds
- Default: 5000
- Can be changed online: yes
Timeout for etcd requests which are allowed to wait for some time.
## etcd_keepalive_timeout
- Type: seconds
- Default: max(30, etcd_report_interval*2)
- Can be changed online: yes
Timeout for etcd connection HTTP Keep-Alive. Should be higher than
etcd_report_interval to guarantee that keepalive actually works.
## etcd_ws_keepalive_interval
- Type: seconds
- Default: 5
- Can be changed online: yes
etcd websocket ping interval required to keep the connection alive and
detect disconnections quickly.

265
docs/config/network.ru.md Normal file
View File

@ -0,0 +1,265 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Параметры сетевого протокола
-----
[Read in English](network.en.md)
# Параметры сетевого протокола
Данные параметры используются клиентами и OSD и влияют на логику сетевого
взаимодействия между клиентами, OSD, а также etcd.
- [tcp_header_buffer_size](#tcp_header_buffer_size)
- [use_sync_send_recv](#use_sync_send_recv)
- [use_rdma](#use_rdma)
- [rdma_device](#rdma_device)
- [rdma_port_num](#rdma_port_num)
- [rdma_gid_index](#rdma_gid_index)
- [rdma_mtu](#rdma_mtu)
- [rdma_max_sge](#rdma_max_sge)
- [rdma_max_msg](#rdma_max_msg)
- [rdma_max_recv](#rdma_max_recv)
- [rdma_max_send](#rdma_max_send)
- [rdma_odp](#rdma_odp)
- [peer_connect_interval](#peer_connect_interval)
- [peer_connect_timeout](#peer_connect_timeout)
- [osd_idle_timeout](#osd_idle_timeout)
- [osd_ping_timeout](#osd_ping_timeout)
- [max_etcd_attempts](#max_etcd_attempts)
- [etcd_quick_timeout](#etcd_quick_timeout)
- [etcd_slow_timeout](#etcd_slow_timeout)
- [etcd_keepalive_timeout](#etcd_keepalive_timeout)
- [etcd_ws_keepalive_interval](#etcd_ws_keepalive_interval)
## tcp_header_buffer_size
- Тип: целое число
- Значение по умолчанию: 65536
Размер буфера для чтения данных с дополнительным копированием. Пакеты
Vitastor содержат 128-байтные заголовки, за которыми следуют данные размером
от 4 КБ и для мелких операций ввода-вывода обычно выгодно за 1 вызов читать
сразу несколько пакетов, даже не смотря на то, что это требует лишний раз
скопировать данные. Часть каждого пакета за пределами значения данного
параметра читается без дополнительного копирования. Вы можете попробовать
поменять этот параметр и посмотреть, как он влияет на производительность
случайного и линейного доступа.
## use_sync_send_recv
- Тип: булево (да/нет)
- Значение по умолчанию: false
Если установлено в истину, то вместо io_uring для передачи данных по сети
будут использоваться обычные синхронные системные вызовы send/recv. Для OSD
это бессмысленно, так как OSD в любом случае нуждается в io_uring, но, в
принципе, это может применяться для клиентов со старыми версиями ядра.
## use_rdma
- Тип: булево (да/нет)
- Значение по умолчанию: true
Пытаться использовать RDMA для связи при наличии доступных устройств.
Отключите, если вы не хотите, чтобы Vitastor использовал RDMA.
TCP-клиенты также могут работать с RDMA-кластером, так что отключать
RDMA может быть нужно только если у клиентов есть RDMA-устройства,
но они не имеют соединения с кластером Vitastor.
## rdma_device
- Тип: строка
Название RDMA-устройства для связи с Vitastor OSD (например, "rocep5s0f0").
Сейчас Vitastor поддерживает все модели адаптеров, включая те, у которых
нет поддержки ODP, то есть вы можете использовать RDMA с ConnectX-3 и
картами производства не Mellanox.
Версии Vitastor до 1.2.0 включительно требовали ODP, который есть только
на Mellanox ConnectX 4 и более новых. См. также [rdma_odp](#rdma_odp).
Запустите `ibv_devinfo -v` от имени суперпользователя, чтобы посмотреть
список доступных RDMA-устройств, их параметры и возможности.
Обратите внимание, что если вы используете RoCE/RoCEv2, вам также необходимо
правильно настроить для него коммутаторы, иначе вы можете столкнуться с
нестабильной производительностью. Подробную информацию о настройке
коммутатора для RoCEv2 ищите в документации производителя. Обычно это
подразумевает настройку сети без потерь на основе PFC (Priority Flow
Control) и ECN (Explicit Congestion Notification).
## rdma_port_num
- Тип: целое число
- Значение по умолчанию: 1
Номер порта RDMA-устройства, который следует использовать. Имеет смысл
только для устройств, у которых более 1 порта. Чтобы узнать, сколько портов
у вашего адаптера, посмотрите `phys_port_cnt` в выводе команды
`ibv_devinfo -v`.
## rdma_gid_index
- Тип: целое число
- Значение по умолчанию: 0
Номер глобального идентификатора адреса RDMA-устройства, который следует
использовать. Разным gid_index могут соответствовать разные протоколы связи:
RoCEv1, RoCEv2, iWARP. Чтобы понять, какой нужен вам - смотрите строчки со
словом "GID" в выводе команды `ibv_devinfo -v`.
**ВАЖНО:** Если вы хотите использовать RoCEv2 (как мы и рекомендуем), то
правильный rdma_gid_index, как правило, 1 (IPv6) или 3 (IPv4).
## rdma_mtu
- Тип: целое число
- Значение по умолчанию: 4096
Максимальная единица передачи (Path MTU) для RDMA. Должно быть равно 1024,
2048 или 4096. Обычно нет смысла менять значение по умолчанию, равное 4096.
## rdma_max_sge
- Тип: целое число
- Значение по умолчанию: 128
Максимальное число записей разделения/сборки (scatter/gather) для RDMA.
OSD в любом случае согласовывают реальное значение при установке соединения,
так что менять этот параметр обычно не нужно.
## rdma_max_msg
- Тип: целое число
- Значение по умолчанию: 132096
Максимальный размер одной RDMA-операции отправки или приёма.
## rdma_max_recv
- Тип: целое число
- Значение по умолчанию: 16
Максимальное число буферов для RDMA-приёма данных на одно соединение
(RDMA требует заранее выделенных буферов для приёма данных). Каждый буфер
имеет размер `rdma_max_msg` байт. Таким образом, настройка прямо влияет на
потребление памяти - один Vitastor-клиент с RDMA использует
`rdma_max_recv * rdma_max_msg * ЧИСЛО_OSD` байт памяти, по умолчанию -
примерно 2 МБ * число OSD.
## rdma_max_send
- Тип: целое число
- Значение по умолчанию: 8
Максимальное число RDMA-операций отправки, отправляемых в очередь одного
соединения. Желательно, чтобы оно было меньше `rdma_max_recv`, чтобы
у принимающей стороны в процессе работы не заканчивались буферы на приём.
Не влияет на потребление памяти - дополнительная память на операции отправки
не выделяется.
## rdma_odp
- Тип: булево (да/нет)
- Значение по умолчанию: false
Использовать RDMA с On-Demand Paging. ODP - функция, доступная пока что
исключительно на адаптерах Mellanox ConnectX-4 и более новых. ODP позволяет
не регистрировать память для её использования RDMA-картой. Благодаря этому
можно не копировать данные при отправке их в сеть и, казалось бы, это должно
улучшать производительность - но **по факту** получается так, что
производительность только ухудшается, причём сильно. Пример - на 3-узловом
кластере с 8 NVMe в каждом узле и сетью 2*25 Гбит/с на чтение с RDMA без ODP
удаётся снять 3950000 iops, а с ODP - всего 239000 iops...
Это происходит из-за того, что реализация ODP у Mellanox неоптимальная и
основана на повторной передаче сообщений, когда карте не известен буфер -
вероятно, на стандартных "RNR retransmission" (RNR = receiver not ready).
А данные повторные передачи в RDMA/RoCE - всегда очень медленная штука.
Презентация на эту тему с конференции ISPASS-2021: https://tkygtr6.github.io/pub/ISPASS21_slides.pdf
Возможность использования ODP сохранена в коде на случай, если вдруг в один
прекрасный день появится хорошая реализация ODP.
## peer_connect_interval
- Тип: секунды
- Значение по умолчанию: 5
- Минимальное значение: 1
- Можно менять на лету: да
Время ожидания перед повторной попыткой соединиться с недоступным OSD.
## peer_connect_timeout
- Тип: секунды
- Значение по умолчанию: 5
- Минимальное значение: 1
- Можно менять на лету: да
Максимальное время ожидания попытки соединения с OSD.
## osd_idle_timeout
- Тип: секунды
- Значение по умолчанию: 5
- Минимальное значение: 1
- Можно менять на лету: да
Время неактивности соединения с OSD, после которого клиенты или другие OSD
посылают запрос проверки состояния соединения.
## osd_ping_timeout
- Тип: секунды
- Значение по умолчанию: 5
- Минимальное значение: 1
- Можно менять на лету: да
Максимальное время ожидания ответа на запрос проверки состояния соединения.
Если OSD не отвечает за это время, соединение отключается и производится
повторная попытка соединения.
## max_etcd_attempts
- Тип: целое число
- Значение по умолчанию: 5
- Можно менять на лету: да
Максимальное число попыток выполнения запросов к etcd для тех запросов,
которые нельзя повторять бесконечно.
## etcd_quick_timeout
- Тип: миллисекунды
- Значение по умолчанию: 1000
- Можно менять на лету: да
Максимальное время выполнения запросов к etcd, которые должны завершаться
быстро, таких, как обновление резервации (lease).
## etcd_slow_timeout
- Тип: миллисекунды
- Значение по умолчанию: 5000
- Можно менять на лету: да
Максимальное время выполнения запросов к etcd, для которых не обязательно
гарантировать быстрое выполнение.
## etcd_keepalive_timeout
- Тип: секунды
- Значение по умолчанию: max(30, etcd_report_interval*2)
- Можно менять на лету: да
Таймаут для HTTP Keep-Alive в соединениях к etcd. Должен быть больше, чем
etcd_report_interval, чтобы keepalive гарантированно работал.
## etcd_ws_keepalive_interval
- Тип: секунды
- Значение по умолчанию: 5
- Можно менять на лету: да
Интервал проверки живости вебсокет-подключений к etcd.

618
docs/config/osd.en.md Normal file
View File

@ -0,0 +1,618 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Runtime OSD Parameters
-----
[Читать на русском](osd.ru.md)
# Runtime OSD Parameters
These parameters only apply to OSDs, are not fixed at the moment of OSD drive
initialization and can be changed - either with an OSD restart or, for some of
them, even without restarting by updating configuration in etcd.
- [etcd_report_interval](#etcd_report_interval)
- [etcd_stats_interval](#etcd_stats_interval)
- [run_primary](#run_primary)
- [osd_network](#osd_network)
- [bind_address](#bind_address)
- [bind_port](#bind_port)
- [autosync_interval](#autosync_interval)
- [autosync_writes](#autosync_writes)
- [recovery_queue_depth](#recovery_queue_depth)
- [recovery_sleep_us](#recovery_sleep_us)
- [recovery_pg_switch](#recovery_pg_switch)
- [recovery_sync_batch](#recovery_sync_batch)
- [readonly](#readonly)
- [no_recovery](#no_recovery)
- [no_rebalance](#no_rebalance)
- [print_stats_interval](#print_stats_interval)
- [slow_log_interval](#slow_log_interval)
- [inode_vanish_time](#inode_vanish_time)
- [max_write_iodepth](#max_write_iodepth)
- [min_flusher_count](#min_flusher_count)
- [max_flusher_count](#max_flusher_count)
- [inmemory_metadata](#inmemory_metadata)
- [inmemory_journal](#inmemory_journal)
- [data_io](#data_io)
- [meta_io](#meta_io)
- [journal_io](#journal_io)
- [journal_sector_buffer_count](#journal_sector_buffer_count)
- [journal_no_same_sector_overwrites](#journal_no_same_sector_overwrites)
- [throttle_small_writes](#throttle_small_writes)
- [throttle_target_iops](#throttle_target_iops)
- [throttle_target_mbs](#throttle_target_mbs)
- [throttle_target_parallelism](#throttle_target_parallelism)
- [throttle_threshold_us](#throttle_threshold_us)
- [osd_memlock](#osd_memlock)
- [auto_scrub](#auto_scrub)
- [no_scrub](#no_scrub)
- [scrub_interval](#scrub_interval)
- [scrub_queue_depth](#scrub_queue_depth)
- [scrub_sleep](#scrub_sleep)
- [scrub_list_limit](#scrub_list_limit)
- [scrub_find_best](#scrub_find_best)
- [scrub_ec_max_bruteforce](#scrub_ec_max_bruteforce)
- [recovery_tune_interval](#recovery_tune_interval)
- [recovery_tune_util_low](#recovery_tune_util_low)
- [recovery_tune_util_high](#recovery_tune_util_high)
- [recovery_tune_client_util_low](#recovery_tune_client_util_low)
- [recovery_tune_client_util_high](#recovery_tune_client_util_high)
- [recovery_tune_agg_interval](#recovery_tune_agg_interval)
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
## etcd_report_interval
- Type: seconds
- Default: 5
Interval at which OSDs report their liveness to etcd. Affects OSD lease time
and thus the failover speed. Lease time is equal to this parameter value
plus max_etcd_attempts * etcd_quick_timeout because it should be guaranteed
that every OSD always refreshes its lease in time.
## etcd_stats_interval
- Type: seconds
- Default: 30
Interval at which OSDs report their statistics to etcd. Highly affects the
imposed load on etcd, because statistics include a key for every OSD and
for every PG. At the same time, low statistic intervals make `vitastor-cli`
statistics more responsive.
## run_primary
- Type: boolean
- Default: true
Start primary OSD logic on this OSD. As of now, can be turned off only for
debugging purposes. It's possible to implement additional feature for the
monitor which may allow to separate primary and secondary OSDs, but it's
unclear why anyone could need it, so it's not implemented.
## osd_network
- Type: string or array of strings
Network mask of the network (IPv4 or IPv6) to use for OSDs. Note that
although it's possible to specify multiple networks here, this does not
mean that OSDs will create multiple listening sockets - they'll only
pick the first matching address of an UP + RUNNING interface. Separate
networks for cluster and client connections are also not implemented, but
they are mostly useless anyway, so it's not a big deal.
## bind_address
- Type: string
- Default: 0.0.0.0
Instead of the network mask, you can also set OSD listen address explicitly
using this parameter. May be useful if you want to start OSDs on interfaces
that are not UP + RUNNING.
## bind_port
- Type: integer
By default, OSDs pick random ports to use for incoming connections
automatically. With this option you can set a specific port for a specific
OSD by hand.
## autosync_interval
- Type: seconds
- Default: 5
- Can be changed online: yes
Time interval at which automatic fsyncs/flushes are issued by each OSD when
the immediate_commit mode if disabled. fsyncs are required because without
them OSDs quickly fill their journals, become unable to clear them and
stall. Also this option limits the amount of recent uncommitted changes
which OSDs may lose in case of a power outage in case when clients don't
issue fsyncs at all.
## autosync_writes
- Type: integer
- Default: 128
- Can be changed online: yes
Same as autosync_interval, but sets the maximum number of uncommitted write
operations before issuing an fsync operation internally.
## recovery_queue_depth
- Type: integer
- Default: 1
- Can be changed online: yes
Maximum recovery and rebalance operations initiated by each OSD in parallel.
Note that each OSD talks to a lot of other OSDs so actual number of parallel
recovery operations per each OSD is greater than just recovery_queue_depth.
Increasing this parameter can speedup recovery if [auto-tuning](#recovery_tune_interval)
allows it or if it is disabled.
## recovery_sleep_us
- Type: microseconds
- Default: 0
- Can be changed online: yes
Delay for all recovery- and rebalance- related operations. If non-zero,
such operations are artificially slowed down to reduce the impact on
client I/O.
## recovery_pg_switch
- Type: integer
- Default: 128
- Can be changed online: yes
Number of recovery operations before switching to recovery of the next PG.
The idea is to mix all PGs during recovery for more even space and load
distribution but still benefit from recovery queue depth greater than 1.
Degraded PGs are anyway scanned first.
## recovery_sync_batch
- Type: integer
- Default: 16
- Can be changed online: yes
Maximum number of recovery operations before issuing an additional fsync.
## readonly
- Type: boolean
- Default: false
Read-only mode. If this is enabled, an OSD will never issue any writes to
the underlying device. This may be useful for recovery purposes.
## no_recovery
- Type: boolean
- Default: false
- Can be changed online: yes
Disable automatic background recovery of objects. Note that it doesn't
affect implicit recovery of objects happening during writes - a write is
always made to a full set of at least pg_minsize OSDs.
## no_rebalance
- Type: boolean
- Default: false
- Can be changed online: yes
Disable background movement of data between different OSDs. Disabling it
means that PGs in the `has_misplaced` state will be left in it indefinitely.
## print_stats_interval
- Type: seconds
- Default: 3
- Can be changed online: yes
Time interval at which OSDs print simple human-readable operation
statistics on stdout.
## slow_log_interval
- Type: seconds
- Default: 10
- Can be changed online: yes
Time interval at which OSDs dump slow or stuck operations on stdout, if
they're any. Also it's the time after which an operation is considered
"slow".
## inode_vanish_time
- Type: seconds
- Default: 60
- Can be changed online: yes
Number of seconds after which a deleted inode is removed from OSD statistics.
## max_write_iodepth
- Type: integer
- Default: 128
- Can be changed online: yes
Parallel client write operation limit per one OSD. Operations that exceed
this limit are pushed to a temporary queue instead of being executed
immediately.
## min_flusher_count
- Type: integer
- Default: 1
- Can be changed online: yes
Flusher is a micro-thread that moves data from the journal to the data
area of the device. Their number is auto-tuned between minimum and maximum.
Minimum number is set by this parameter.
## max_flusher_count
- Type: integer
- Default: 256
- Can be changed online: yes
Maximum number of journal flushers (see above min_flusher_count).
## inmemory_metadata
- Type: boolean
- Default: true
This parameter makes Vitastor always keep metadata area of the block device
in memory. It's required for good performance because it allows to avoid
additional read-modify-write cycles during metadata modifications. Metadata
area size is currently roughly 224 MB per 1 TB of data. You can turn it off
to reduce memory usage by this value, but it will hurt performance. This
restriction is likely to be removed in the future along with the upgrade
of the metadata storage scheme.
## inmemory_journal
- Type: boolean
- Default: true
This parameter make Vitastor always keep journal area of the block
device in memory. Turning it off will, again, reduce memory usage, but
hurt performance because flusher coroutines will have to read data from
the disk back before copying it into the main area. The memory usage benefit
is typically very small because it's sufficient to have 16-32 MB journal
for SSD OSDs. However, in theory it's possible that you'll want to turn it
off for hybrid (HDD+SSD) OSDs with large journals on quick devices.
## data_io
- Type: string
- Default: direct
I/O mode for *data*. One of "direct", "cached" or "directsync". Corresponds
to O_DIRECT, O_SYNC and O_DIRECT|O_SYNC, respectively.
Choose "cached" to use Linux page cache. This may improve read performance
for hot data and slower disks - HDDs and maybe SATA SSDs - but will slightly
decrease write performance for fast disks because page cache is an overhead
itself.
Choose "directsync" to use [immediate_commit](layout-cluster.ru.md#immediate_commit)
(which requires disable_data_fsync) with drives having write-back cache
which can't be turned off, for example, Intel Optane. Also note that *some*
desktop SSDs (for example, HP EX950) may ignore O_SYNC thus making
disable_data_fsync unsafe even with "directsync".
## meta_io
- Type: string
- Default: direct
I/O mode for *metadata*. One of "direct", "cached" or "directsync".
"cached" may improve read performance, but only under the following conditions:
1. your drives are relatively slow (HDD, SATA SSD), and
2. checksums are enabled, and
3. [inmemory_metadata](#inmemory_metadata) is disabled.
Under all these conditions, metadata blocks are read from disk on every
read request to verify checksums and caching them may reduce this extra
read load. Without (3) metadata is never read from the disk after starting,
and without (2) metadata blocks are read from disk only during journal
flushing.
"directsync" is the same as above.
If the same device is used for data and metadata, meta_io by default is set
to the same value as [data_io](#data_io).
## journal_io
- Type: string
- Default: direct
I/O mode for *journal*. One of "direct", "cached" or "directsync".
Here, "cached" may only improve read performance for recent writes and
only if [inmemory_journal](#inmemory_journal) is turned off.
If the same device is used for metadata and journal, journal_io by default
is set to the same value as [meta_io](#meta_io).
## journal_sector_buffer_count
- Type: integer
- Default: 32
Maximum number of buffers that can be used for writing journal metadata
blocks. The only situation when you should increase it to a larger value
is when you enable journal_no_same_sector_overwrites. In this case set
it to, for example, 1024.
## journal_no_same_sector_overwrites
- Type: boolean
- Default: false
Enable this option for SSDs like Intel D3-S4510 and D3-S4610 which REALLY
don't like when a program overwrites the same sector multiple times in a
row and slow down significantly (from 25000+ iops to ~3000 iops). When
this option is set, Vitastor will always move to the next sector of the
journal after writing it instead of possibly overwriting it the second time.
Most (99%) other SSDs don't need this option.
## throttle_small_writes
- Type: boolean
- Default: false
- Can be changed online: yes
Enable soft throttling of small journaled writes. Useful for hybrid OSDs
with fast journal/metadata devices and slow data devices. The idea is that
small writes complete very quickly because they're first written to the
journal device, but moving them to the main device is slow. So if an OSD
allows clients to issue a lot of small writes it will perform very good
for several seconds and then the journal will fill up and the performance
will drop to almost zero. Throttling is meant to prevent this problem by
artifically slowing quick writes down based on the amount of free space in
the journal. When throttling is used, the performance of small writes will
decrease smoothly instead of abrupt drop at the moment when the journal
fills up.
## throttle_target_iops
- Type: integer
- Default: 100
- Can be changed online: yes
Target maximum number of throttled operations per second under the condition
of full journal. Set it to approximate random write iops of your data devices
(HDDs).
## throttle_target_mbs
- Type: integer
- Default: 100
- Can be changed online: yes
Target maximum bandwidth in MB/s of throttled operations per second under
the condition of full journal. Set it to approximate linear write
performance of your data devices (HDDs).
## throttle_target_parallelism
- Type: integer
- Default: 1
- Can be changed online: yes
Target maximum parallelism of throttled operations under the condition of
full journal. Set it to approximate internal parallelism of your data
devices (1 for HDDs, 4-8 for SSDs).
## throttle_threshold_us
- Type: microseconds
- Default: 50
- Can be changed online: yes
Minimal computed delay to be applied to throttled operations. Usually
doesn't need to be changed.
## osd_memlock
- Type: boolean
- Default: false
Lock all OSD memory to prevent it from being unloaded into swap with
mlockall(). Requires sufficient ulimit -l (max locked memory).
## auto_scrub
- Type: boolean
- Default: false
- Can be changed online: yes
Data scrubbing is the process of background verification of copies to find
and repair corrupted blocks. It's not run automatically by default since
it's a new feature. Set this parameter to true to enable automatic scrubs.
This parameter makes OSDs automatically schedule data scrubbing of clean PGs
every `scrub_interval` (see below). You can also start/schedule scrubbing
manually by setting `next_scrub` JSON key to the desired UNIX time of the
next scrub in `/pg/history/...` values in etcd.
## no_scrub
- Type: boolean
- Default: false
- Can be changed online: yes
Temporarily disable scrubbing and stop running scrubs.
## scrub_interval
- Type: string
- Default: 30d
- Can be changed online: yes
Default automatic scrubbing interval for all pools. Numbers without suffix
are treated as seconds, possible unit suffixes include 's' (seconds),
'm' (minutes), 'h' (hours), 'd' (days), 'M' (months) and 'y' (years).
## scrub_queue_depth
- Type: integer
- Default: 1
- Can be changed online: yes
Number of parallel scrubbing operations per one OSD.
## scrub_sleep
- Type: milliseconds
- Default: 0
- Can be changed online: yes
Additional interval between two consecutive scrubbing operations on one OSD.
Can be used to slow down scrubbing if it affects user load too much.
## scrub_list_limit
- Type: integer
- Default: 1000
- Can be changed online: yes
Number of objects to list in one listing operation during scrub.
## scrub_find_best
- Type: boolean
- Default: true
- Can be changed online: yes
Find and automatically restore best versions of objects with unmatched
copies. In replicated setups, the best version is the version with most
matching replicas. In EC setups, the best version is the subset of data
and parity chunks without mismatches.
The hypothetical situation where you might want to disable it is when
you have 3 replicas and you are paranoid that 2 HDDs out of 3 may silently
corrupt an object in the same way (for example, zero it out) and only
1 HDD will remain good. In this case disabling scrub_find_best may help
you to recover the data! See also scrub_ec_max_bruteforce below.
## scrub_ec_max_bruteforce
- Type: integer
- Default: 100
- Can be changed online: yes
Vitastor can locate corrupted chunks in EC setups with more than 1 parity
chunk by brute-forcing all possible error locations. This configuration
value limits the maximum number of checked combinations. You can try to
increase it if you have EC N+K setup with N and K large enough for
combination count `C(N+K-1, K-1) = (N+K-1)! / (K-1)! / N!` to be greater
than the default 100.
If there are too many possible combinations or if multiple combinations give
correct results then objects are marked inconsistent and aren't recovered
automatically.
In replicated setups bruteforcing isn't needed, Vitastor just assumes that
the variant with most available equal copies is correct. For example, if
you have 3 replicas and 1 of them differs, this one is considered to be
corrupted. But if there is no "best" version with more copies than all
others have then the object is also marked as inconsistent.
## recovery_tune_interval
- Type: seconds
- Default: 1
- Can be changed online: yes
Interval at which OSD re-considers client and recovery load and automatically
adjusts [recovery_sleep_us](#recovery_sleep_us). Recovery auto-tuning is
disabled if recovery_tune_interval is set to 0.
Auto-tuning targets utilization. Utilization is a measure of load and is
equal to the product of iops and average latency (so it may be greater
than 1). You set "low" and "high" client utilization thresholds and two
corresponding target recovery utilization levels. OSD calculates desired
recovery utilization from client utilization using linear interpolation
and auto-tunes recovery operation delay to make actual recovery utilization
match desired.
This allows to reduce recovery/rebalance impact on client operations. It is
of course impossible to remove it completely, but it should become adequate.
In some tests rebalance could earlier drop client write speed from 1.5 GB/s
to 50-100 MB/s, with default auto-tuning settings it now only reduces
to ~1 GB/s.
## recovery_tune_util_low
- Type: number
- Default: 0.1
- Can be changed online: yes
Desired recovery/rebalance utilization when client load is high, i.e. when
it is at or above recovery_tune_client_util_high.
## recovery_tune_util_high
- Type: number
- Default: 1
- Can be changed online: yes
Desired recovery/rebalance utilization when client load is low, i.e. when
it is at or below recovery_tune_client_util_low.
## recovery_tune_client_util_low
- Type: number
- Default: 0
- Can be changed online: yes
Client utilization considered "low".
## recovery_tune_client_util_high
- Type: number
- Default: 0.5
- Can be changed online: yes
Client utilization considered "high".
## recovery_tune_agg_interval
- Type: integer
- Default: 10
- Can be changed online: yes
The number of last auto-tuning iterations to use for calculating the
delay as average. Lower values result in quicker response to client
load change, higher values result in more stable delay. Default value of 10
is usually fine.
## recovery_tune_sleep_min_us
- Type: microseconds
- Default: 10
- Can be changed online: yes
Minimum possible value for auto-tuned recovery_sleep_us. Lower values
are changed to 0.
## recovery_tune_sleep_cutoff_us
- Type: microseconds
- Default: 10000000
- Can be changed online: yes
Maximum possible value for auto-tuned recovery_sleep_us. Higher values
are treated as outliers and ignored in aggregation.

648
docs/config/osd.ru.md Normal file
View File

@ -0,0 +1,648 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Изменяемые параметры OSD
-----
[Read in English](osd.en.md)
# Изменяемые параметры OSD
Данные параметры используются только OSD, но, в отличие от дисковых параметров,
не фиксируются в момент инициализации дисков OSD и могут быть изменены в любой
момент с помощью перезапуска OSD, а некоторые и без перезапуска, с помощью
изменения конфигурации в etcd.
- [etcd_report_interval](#etcd_report_interval)
- [etcd_stats_interval](#etcd_stats_interval)
- [run_primary](#run_primary)
- [osd_network](#osd_network)
- [bind_address](#bind_address)
- [bind_port](#bind_port)
- [autosync_interval](#autosync_interval)
- [autosync_writes](#autosync_writes)
- [recovery_queue_depth](#recovery_queue_depth)
- [recovery_sleep_us](#recovery_sleep_us)
- [recovery_pg_switch](#recovery_pg_switch)
- [recovery_sync_batch](#recovery_sync_batch)
- [readonly](#readonly)
- [no_recovery](#no_recovery)
- [no_rebalance](#no_rebalance)
- [print_stats_interval](#print_stats_interval)
- [slow_log_interval](#slow_log_interval)
- [inode_vanish_time](#inode_vanish_time)
- [max_write_iodepth](#max_write_iodepth)
- [min_flusher_count](#min_flusher_count)
- [max_flusher_count](#max_flusher_count)
- [inmemory_metadata](#inmemory_metadata)
- [inmemory_journal](#inmemory_journal)
- [data_io](#data_io)
- [meta_io](#meta_io)
- [journal_io](#journal_io)
- [journal_sector_buffer_count](#journal_sector_buffer_count)
- [journal_no_same_sector_overwrites](#journal_no_same_sector_overwrites)
- [throttle_small_writes](#throttle_small_writes)
- [throttle_target_iops](#throttle_target_iops)
- [throttle_target_mbs](#throttle_target_mbs)
- [throttle_target_parallelism](#throttle_target_parallelism)
- [throttle_threshold_us](#throttle_threshold_us)
- [osd_memlock](#osd_memlock)
- [auto_scrub](#auto_scrub)
- [no_scrub](#no_scrub)
- [scrub_interval](#scrub_interval)
- [scrub_queue_depth](#scrub_queue_depth)
- [scrub_sleep](#scrub_sleep)
- [scrub_list_limit](#scrub_list_limit)
- [scrub_find_best](#scrub_find_best)
- [scrub_ec_max_bruteforce](#scrub_ec_max_bruteforce)
- [recovery_tune_interval](#recovery_tune_interval)
- [recovery_tune_util_low](#recovery_tune_util_low)
- [recovery_tune_util_high](#recovery_tune_util_high)
- [recovery_tune_client_util_low](#recovery_tune_client_util_low)
- [recovery_tune_client_util_high](#recovery_tune_client_util_high)
- [recovery_tune_agg_interval](#recovery_tune_agg_interval)
- [recovery_tune_sleep_min_us](#recovery_tune_sleep_min_us)
- [recovery_tune_sleep_cutoff_us](#recovery_tune_sleep_cutoff_us)
## etcd_report_interval
- Тип: секунды
- Значение по умолчанию: 5
Интервал, с которым OSD сообщает о том, что жив, в etcd. Значение параметра
влияет на время резервации (lease) OSD и поэтому - на скорость переключения
при падении OSD. Время lease равняется значению этого параметра плюс
max_etcd_attempts * etcd_quick_timeout.
## etcd_stats_interval
- Тип: секунды
- Значение по умолчанию: 30
Интервал, с которым OSD обновляет свою статистику в etcd. Сильно влияет на
создаваемую нагрузку на etcd, потому что статистика содержит по ключу на
каждый OSD и на каждую PG. В то же время низкий интервал делает
статистику, печатаемую `vitastor-cli`, отзывчивей.
## run_primary
- Тип: булево (да/нет)
- Значение по умолчанию: true
Запускать логику первичного OSD на данном OSD. На данный момент отключать
эту опцию может иметь смысл только в целях отладки. В теории, можно
реализовать дополнительный режим для монитора, который позволит отделять
первичные OSD от вторичных, но пока не понятно, зачем это может кому-то
понадобиться, поэтому это не реализовано.
## osd_network
- Тип: строка или массив строк
Маска подсети (IPv4 или IPv6) для использования для соединений с OSD.
Имейте в виду, что хотя сейчас и можно передать в этот параметр несколько
подсетей, это не означает, что OSD будут создавать несколько слушающих
сокетов - они лишь будут выбирать адрес первого поднятого (состояние UP +
RUNNING), подходящий под заданную маску. Также не реализовано разделение
кластерной и публичной сетей OSD. Правда, от него обычно всё равно довольно
мало толку, так что особенной проблемы в этом нет.
## bind_address
- Тип: строка
- Значение по умолчанию: 0.0.0.0
Этим параметром можно явным образом задать адрес, на котором будет ожидать
соединений OSD (вместо использования маски подсети). Может быть полезно,
например, чтобы запускать OSD на неподнятых интерфейсах (не UP + RUNNING).
## bind_port
- Тип: целое число
По умолчанию OSD сами выбирают случайные порты для входящих подключений.
С помощью данной опции вы можете задать порт для отдельного OSD вручную.
## autosync_interval
- Тип: секунды
- Значение по умолчанию: 5
- Можно менять на лету: да
Временной интервал отправки автоматических fsync-ов (операций очистки кэша)
каждым OSD для случая, когда режим immediate_commit отключён. fsync-и нужны
OSD, чтобы успевать очищать журнал - без них OSD быстро заполняют журналы и
перестают обрабатывать операции записи. Также эта опция ограничивает объём
недавних незафиксированных изменений, которые OSD могут терять при
отключении питания, если клиенты вообще не отправляют fsync.
## autosync_writes
- Тип: целое число
- Значение по умолчанию: 128
- Можно менять на лету: да
Аналогично autosync_interval, но задаёт не временной интервал, а
максимальное количество незафиксированных операций записи перед
принудительной отправкой fsync-а.
## recovery_queue_depth
- Тип: целое число
- Значение по умолчанию: 1
- Можно менять на лету: да
Максимальное число параллельных операций восстановления, инициируемых одним
OSD в любой момент времени. Имейте в виду, что каждый OSD обычно работает с
многими другими OSD, так что на практике параллелизм восстановления больше,
чем просто recovery_queue_depth. Увеличение значения этого параметра может
ускорить восстановление если [автотюнинг скорости](#recovery_tune_interval)
разрешает это или если он отключён.
## recovery_sleep_us
- Тип: микросекунды
- Значение по умолчанию: 0
- Можно менять на лету: да
Delay for all recovery- and rebalance- related operations. If non-zero,
such operations are artificially slowed down to reduce the impact on
client I/O.
## recovery_pg_switch
- Тип: целое число
- Значение по умолчанию: 128
- Можно менять на лету: да
Число операций восстановления перед переключением на восстановление другой PG.
Идея заключается в том, чтобы восстанавливать все PG одновременно для более
равномерного распределения места и нагрузки, но при этом всё равно выигрывать
от глубины очереди восстановления, большей, чем 1. Деградированные PG в любом
случае сканируются первыми.
## recovery_sync_batch
- Тип: целое число
- Значение по умолчанию: 16
- Можно менять на лету: да
Максимальное число операций восстановления перед дополнительным fsync.
## readonly
- Тип: булево (да/нет)
- Значение по умолчанию: false
Режим "только чтение". Если включить этот режим, OSD не будет писать ничего
на диск. Может быть полезно в целях восстановления.
## no_recovery
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Отключить автоматическое фоновое восстановление объектов. Обратите внимание,
что эта опция не отключает восстановление объектов, происходящее при
записи - запись всегда производится в полный набор из как минимум pg_minsize
OSD.
## no_rebalance
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Отключить фоновое перемещение объектов между разными OSD. Отключение
означает, что PG, находящиеся в состоянии `has_misplaced`, будут оставлены
в нём на неопределённый срок.
## print_stats_interval
- Тип: секунды
- Значение по умолчанию: 3
- Можно менять на лету: да
Временной интервал, с которым OSD печатают простую человекочитаемую
статистику выполнения операций в стандартный вывод.
## slow_log_interval
- Тип: секунды
- Значение по умолчанию: 10
- Можно менять на лету: да
Временной интервал, с которым OSD выводят в стандартный вывод список
медленных или зависших операций, если таковые имеются. Также время, при
превышении которого операция считается "медленной".
## inode_vanish_time
- Тип: секунды
- Значение по умолчанию: 60
- Можно менять на лету: да
Число секунд, через которое удалённые инод удаляется и из статистики OSD.
## max_write_iodepth
- Тип: целое число
- Значение по умолчанию: 128
- Можно менять на лету: да
Максимальное число одновременных клиентских операций записи на один OSD.
Операции, превышающие этот лимит, не исполняются сразу, а сохраняются во
временной очереди.
## min_flusher_count
- Тип: целое число
- Значение по умолчанию: 1
- Можно менять на лету: да
Flusher - это микро-поток (корутина), которая копирует данные из журнала в
основную область устройства данных. Их число настраивается динамически между
минимальным и максимальным значением. Этот параметр задаёт минимальное число.
## max_flusher_count
- Тип: целое число
- Значение по умолчанию: 256
- Можно менять на лету: да
Максимальное число микро-потоков очистки журнала (см. выше min_flusher_count).
## inmemory_metadata
- Тип: булево (да/нет)
- Значение по умолчанию: true
Данный параметр заставляет Vitastor всегда держать область метаданных диска
в памяти. Это нужно, чтобы избегать дополнительных операций чтения с диска
при записи. Размер области метаданных на данный момент составляет примерно
224 МБ на 1 ТБ данных. При включении потребление памяти снизится примерно
на эту величину, но при этом также снизится и производительность. В будущем,
после обновления схемы хранения метаданных, это ограничение, скорее всего,
будет ликвидировано.
## inmemory_journal
- Тип: булево (да/нет)
- Значение по умолчанию: true
Данный параметр заставляет Vitastor всегда держать в памяти журналы OSD.
Отключение параметра, опять же, снижает потребление памяти, но ухудшает
производительность, так как для копирования данных из журнала в основную
область устройства OSD будут вынуждены читать их обратно с диска. Выигрыш
по памяти при этом обычно крайне низкий, так как для SSD OSD обычно
достаточно 16- или 32-мегабайтного журнала. Однако в теории отключение
параметра может оказаться полезным для гибридных OSD (HDD+SSD) с большими
журналами, расположенными на быстром по сравнению с HDD устройстве.
## data_io
- Тип: строка
- Значение по умолчанию: direct
Режим ввода-вывода для *данных*. Одно из значений "direct", "cached" или
"directsync", означающих O_DIRECT, O_SYNC и O_DIRECT|O_SYNC, соответственно.
Выберите "cached", чтобы использовать системный кэш Linux (page cache) при
чтении и записи. Это может улучшить скорость чтения горячих данных с
относительно медленных дисков - HDD и, возможно, SATA SSD - но немного
снижает производительность записи для быстрых дисков, так как кэш сам по
себе тоже добавляет накладные расходы.
Выберите "directsync", если хотите задействовать
[immediate_commit](layout-cluster.ru.md#immediate_commit) (требующий
включенияd disable_data_fsync) на дисках с неотключаемым кэшем. Пример таких
дисков - Intel Optane. При этом также стоит иметь в виду, что *некоторые*
настольные SSD (например, HP EX950) игнорируют флаг O_SYNC, делая отключение
fsync небезопасным даже с режимом "directsync".
## meta_io
- Тип: строка
- Значение по умолчанию: direct
Режим ввода-вывода для *метаданных*. Одно из значений "direct", "cached" или
"directsync".
"cached" может улучшить скорость чтения, если:
1. у вас медленные диски (HDD, SATA SSD)
2. контрольные суммы включены
3. параметр [inmemory_metadata](#inmemory_metadata) отключён.
При этих условиях блоки метаданных читаются с диска при каждом запросе чтения
для проверки контрольных сумм и их кэширование может снизить дополнительную
нагрузку на диск. Без (3) метаданные никогда не читаются с диска после
запуска OSD, а без (2) блоки метаданных читаются только при сбросе журнала.
Если одно и то же устройство используется для данных и метаданных, режим
ввода-вывода метаданных по умолчанию устанавливается равным [data_io](#data_io).
## journal_io
- Тип: строка
- Значение по умолчанию: direct
Режим ввода-вывода для *журнала*. Одно из значений "direct", "cached" или
"directsync".
Здесь "cached" может улучшить скорость чтения только недавно записанных
данных и только если параметр [inmemory_journal](#inmemory_journal)
отключён.
Если одно и то же устройство используется для метаданных и журнала,
режим ввода-вывода журнала по умолчанию устанавливается равным
[meta_io](#meta_io).
## journal_sector_buffer_count
- Тип: целое число
- Значение по умолчанию: 32
Максимальное число буферов, разрешённых для использования под записываемые
в журнал блоки метаданных. Единственная ситуация, в которой этот параметр
нужно менять - это если вы включаете journal_no_same_sector_overwrites. В
этом случае установите данный параметр, например, в 1024.
## journal_no_same_sector_overwrites
- Тип: булево (да/нет)
- Значение по умолчанию: false
Включайте данную опцию для SSD вроде Intel D3-S4510 и D3-S4610, которые
ОЧЕНЬ не любят, когда ПО перезаписывает один и тот же сектор несколько раз
подряд. Такие SSD при многократной перезаписи одного и того же сектора
сильно замедляются - условно, с 25000 и более iops до 3000 iops. Когда
данная опция установлена, Vitastor всегда переходит к следующему сектору
журнала после записи вместо потенциально повторной перезаписи того же
самого сектора.
Почти все другие SSD (99% моделей) не требуют данной опции.
## throttle_small_writes
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Разрешить мягкое ограничение скорости журналируемой записи. Полезно для
гибридных OSD с быстрыми устройствами метаданных и медленными устройствами
данных. Идея заключается в том, что мелкие записи в этой ситуации могут
завершаться очень быстро, так как они изначально записываются на быстрое
журнальное устройство (SSD). Но перемещать их потом на основное медленное
устройство долго. Поэтому если OSD быстро примет от клиентов очень много
мелких операций записи, он быстро заполнит свой журнал, после чего
производительность записи резко упадёт практически до нуля. Ограничение
скорости записи призвано решить эту проблему с помощью искусственного
замедления операций записи на основании объёма свободного места в журнале.
Когда эта опция включена, производительность мелких операций записи будет
снижаться плавно, а не резко в момент окончательного заполнения журнала.
## throttle_target_iops
- Тип: целое число
- Значение по умолчанию: 100
- Можно менять на лету: да
Расчётное максимальное число ограничиваемых операций в секунду при условии
отсутствия свободного места в журнале. Устанавливайте приблизительно равным
максимальной производительности случайной записи ваших устройств данных
(HDD) в операциях в секунду.
## throttle_target_mbs
- Тип: целое число
- Значение по умолчанию: 100
- Можно менять на лету: да
Расчётный максимальный размер в МБ/с ограничиваемых операций в секунду при
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
равным максимальной производительности линейной записи ваших устройств
данных (HDD).
## throttle_target_parallelism
- Тип: целое число
- Значение по умолчанию: 1
- Можно менять на лету: да
Расчётный максимальный параллелизм ограничиваемых операций в секунду при
условии отсутствия свободного места в журнале. Устанавливайте приблизительно
равным внутреннему параллелизму ваших устройств данных (1 для HDD, 4-8
для SSD).
## throttle_threshold_us
- Тип: микросекунды
- Значение по умолчанию: 50
- Можно менять на лету: да
Минимальная применимая к ограничиваемым операциям задержка. Обычно не
требует изменений.
## osd_memlock
- Тип: булево (да/нет)
- Значение по умолчанию: false
Блокировать всю память OSD с помощью mlockall, чтобы запретить её выгрузку
в пространство подкачки. Требует достаточного значения ulimit -l (лимита
заблокированной памяти).
## auto_scrub
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Скраб - процесс фоновой проверки копий данных, предназначенный, чтобы
находить и исправлять повреждённые блоки. По умолчанию эти проверки ещё не
запускаются автоматически, так как являются новой функцией. Чтобы включить
автоматическое планирование скрабов, установите данный параметр в true.
Включённый параметр заставляет OSD автоматически планировать фоновую
проверку чистых PG раз в `scrub_interval` (см. ниже). Вы также можете
запустить или запланировать проверку вручную, установив значение ключа JSON
`next_scrub` внутри ключей etcd `/pg/history/...` в UNIX-время следующей
желаемой проверки.
## no_scrub
- Тип: булево (да/нет)
- Значение по умолчанию: false
- Можно менять на лету: да
Временно отключить и остановить запущенные скрабы.
## scrub_interval
- Тип: строка
- Значение по умолчанию: 30d
- Можно менять на лету: да
Интервал автоматической фоновой проверки по умолчанию для всех пулов.
Значения без указанной единицы измерения считаются в секундах, допустимые
символы единиц измерения в конце: 's' (секунды),
'm' (минуты), 'h' (часы), 'd' (дни), 'M' (месяца) или 'y' (годы).
## scrub_queue_depth
- Тип: целое число
- Значение по умолчанию: 1
- Можно менять на лету: да
Число параллельных операций фоновой проверки на один OSD.
## scrub_sleep
- Тип: миллисекунды
- Значение по умолчанию: 0
- Можно менять на лету: да
Дополнительный интервал ожидания после фоновой проверки каждого объекта на
одном OSD. Может использоваться для замедления скраба, если он слишком
сильно влияет на пользовательскую нагрузку.
## scrub_list_limit
- Тип: целое число
- Значение по умолчанию: 1000
- Можно менять на лету: да
Размер загружаемых за одну операцию списков объектов в процессе фоновой
проверки.
## scrub_find_best
- Тип: булево (да/нет)
- Значение по умолчанию: true
- Можно менять на лету: да
Находить и автоматически восстанавливать "лучшие версии" объектов с
несовпадающими копиями/частями. При использовании репликации "лучшая"
версия - версия, доступная в большем числе экземпляров, чем другие. При
использовании кодов коррекции ошибок "лучшая" версия - это подмножество
частей данных и чётности, полностью соответствующих друг другу.
Гипотетическая ситуация, в которой вы можете захотеть отключить этот
поиск - это если у вас 3 реплики и вы боитесь, что 2 диска из 3 могут
незаметно и одинаково повредить данные одного и того же объекта, например,
занулив его, и только 1 диск останется неповреждённым. В этой ситуации
отключение этого параметра поможет вам восстановить данные! Смотрите также
описание следующего параметра - scrub_ec_max_bruteforce.
## scrub_ec_max_bruteforce
- Тип: целое число
- Значение по умолчанию: 100
- Можно менять на лету: да
Vitastor старается определить повреждённые части объектов при использовании
EC (кодов коррекции ошибок) с более, чем 1 диском чётности, путём перебора
всех возможных комбинаций ошибочных частей. Данное значение конфигурации
ограничивает число перебираемых комбинаций. Вы можете попробовать поднять
его, если используете схему кодирования EC N+K с N и K, достаточно большими
для того, чтобы число сочетаний `C(N+K-1, K-1) = (N+K-1)! / (K-1)! / N!`
было больше, чем стандартное значение 100.
Если возможных комбинаций слишком много или если корректная комбинаций не
определяется однозначно, объекты помечаются неконсистентными (inconsistent)
и не восстанавливаются автоматически.
При использовании репликации перебор не нужен, Vitastor просто предполагает,
что вариант объекта с наибольшим количеством одинаковых копий корректен.
Например, если вы используете 3 реплики и 1 из них отличается, эта 1 копия
считается некорректной. Однако, если "лучшую" версию с числом доступных
копий большим, чем у всех других версий, найти невозможно, то объект тоже
маркируется неконсистентным.
## recovery_tune_interval
- Тип: секунды
- Значение по умолчанию: 1
- Можно менять на лету: да
Интервал, с которым OSD пересматривает клиентскую нагрузку и нагрузку
восстановления и автоматически подстраивает [recovery_sleep_us](#recovery_sleep_us).
Автотюнинг (автоподстройка) отключается, если recovery_tune_interval
устанавливается в значение 0.
Автотюнинг регулирует утилизацию. Утилизация является мерой нагрузки
и равна произведению числа операций в секунду и средней задержки
(то есть, она может быть выше 1). Вы задаёте два уровня клиентской
утилизации - "низкий" и "высокий" (low и high) и два соответствующих
целевых уровня утилизации операциями восстановления. OSD рассчитывает
желаемый уровень утилизации восстановления линейной интерполяцией от
клиентской утилизации и подстраивает задержку операций восстановления
так, чтобы фактическая утилизация восстановления совпадала с желаемой.
Это позволяет снизить влияние восстановления и ребаланса на клиентские
операции. Конечно, невозможно исключить такое влияние полностью, но оно
должно становиться адекватнее. В некоторых тестах перебалансировка могла
снижать клиентскую скорость записи с 1.5 ГБ/с до 50-100 МБ/с, а теперь, с
настройками автотюнинга по умолчанию, она снижается только до ~1 ГБ/с.
## recovery_tune_util_low
- Тип: число
- Значение по умолчанию: 0.1
- Можно менять на лету: да
Желаемая утилизация восстановления в моменты, когда клиентская нагрузка
высокая, то есть, находится на уровне или выше recovery_tune_client_util_high.
## recovery_tune_util_high
- Тип: число
- Значение по умолчанию: 1
- Можно менять на лету: да
Желаемая утилизация восстановления в моменты, когда клиентская нагрузка
низкая, то есть, находится на уровне или ниже recovery_tune_client_util_low.
## recovery_tune_client_util_low
- Тип: число
- Значение по умолчанию: 0
- Можно менять на лету: да
Клиентская утилизация, которая считается "низкой".
## recovery_tune_client_util_high
- Тип: число
- Значение по умолчанию: 0.5
- Можно менять на лету: да
Клиентская утилизация, которая считается "высокой".
## recovery_tune_agg_interval
- Тип: целое число
- Значение по умолчанию: 10
- Можно менять на лету: да
Число последних итераций автоподстройки для расчёта задержки как среднего
значения. Меньшие значения параметра ускоряют отклик на изменение нагрузки,
большие значения делают задержку стабильнее. Значение по умолчанию 10
обычно нормальное и не требует изменений.
## recovery_tune_sleep_min_us
- Тип: микросекунды
- Значение по умолчанию: 10
- Можно менять на лету: да
Минимальное возможное значение авто-подстроенного recovery_sleep_us.
Меньшие значения заменяются на 0.
## recovery_tune_sleep_cutoff_us
- Тип: микросекунды
- Значение по умолчанию: 10000000
- Можно менять на лету: да
Максимальное возможное значение авто-подстроенного recovery_sleep_us.
Большие значения считаются случайными выбросами и игнорируются в
усреднении.

430
docs/config/pool.en.md Normal file
View File

@ -0,0 +1,430 @@
[Documentation](../../README.md#documentation) → [Configuration](../config.en.md) → Pool configuration
-----
[Читать на русском](pool.ru.md)
# Pool configuration
Pool configuration is set in etcd key `/vitastor/config/pools` in the following
JSON format:
```
{
"<Numeric ID>": {
"name": "<name>",
...other parameters...
}
}
```
Pool configuration is also affected by:
- [OSD Placement Tree](#placement-tree)
- [Separate OSD settings](#osd-settings)
Parameters:
- [name](#name)
- [scheme](#scheme)
- [pg_size](#pg_size)
- [parity_chunks](#parity_chunks)
- [pg_minsize](#pg_minsize)
- [pg_count](#pg_count)
- [failure_domain](#failure_domain)
- [level_placement](#level_placement)
- [raw_placement](#raw_placement)
- [max_osd_combinations](#max_osd_combinations)
- [block_size](#block_size)
- [bitmap_granularity](#bitmap_granularity)
- [immediate_commit](#immediate_commit)
- [pg_stripe_size](#pg_stripe_size)
- [root_node](#root_node)
- [osd_tags](#osd_tags)
- [primary_affinity_tags](#primary_affinity_tags)
- [scrub_interval](#scrub_interval)
- [used_for_fs](#used_for_fs)
Examples:
- [Replicated Pool](#replicated-pool)
- [Erasure-coded Pool](#erasure-coded-pool)
# Placement Tree
OSD placement tree is set in a separate etcd key `/vitastor/config/node_placement`
in the following JSON format:
`
{
"<node name or OSD number>": {
"level": "<level>",
"parent": "<parent node name, if any>"
},
...
}
`
Here, if a node name is a number then it is assumed to refer to an OSD.
Level of the OSD is always "osd" and cannot be overriden. You may only
override parent node of the OSD which is its host by default.
Non-numeric node names refer to other placement tree nodes like hosts, racks,
datacenters and so on.
Hosts of all OSDs are auto-created in the tree with level "host" and name
equal to the host name reported by a corresponding OSD. You can refer to them
without adding them to this JSON tree manually.
Level may be "host", "osd" or refer to some other placement tree level
from [placement_levels](monitor.en.md#placement_levels).
Parent node reference is required for intermediate tree nodes.
# OSD settings
Separate OSD settings are set in etc keys `/vitastor/config/osd/<number>`
in JSON format `{"<key>":<value>}`.
As of now, the following settings are supported:
- [reweight](#reweight)
- [tags](#tags)
- [noout](#noout)
## reweight
- Type: number, between 0 and 1
- Default: 1
Every OSD receives PGs proportional to its size. Reweight is a multiplier for
OSD size used during PG distribution.
This means an OSD configured with reweight lower than 1 receives less PGs than
it normally would. An OSD with reweight = 0 won't store any data. You can set
reweight to 0 to trigger rebalance and remove all data from an OSD.
## tags
- Type: string or array of strings
Sets tag or multiple tags for this OSD. Tags can be used to group OSDs into
subsets and then use a specific subset for pool instead of all OSDs.
For example you can mark SSD OSDs with tag "ssd" and HDD OSDs with "hdd" and
such tags will work as device classes.
## noout
- Type: boolean
- Default: false
If set to true, [osd_out_time](monitor.en.md#osd_out_time) is ignored for this
OSD and it's never removed from data distribution by the monitor.
# Pool parameters
## name
- Type: string
- Required
Pool name.
## scheme
- Type: string
- Required
- One of: "replicated", "xor", "ec" or "jerasure"
Redundancy scheme used for data in this pool. "jerasure" is an alias for "ec",
both use Reed-Solomon-Vandermonde codes based on ISA-L or jerasure libraries.
Fast ISA-L based implementation is used automatically when it's available,
slower jerasure version is used otherwise.
## pg_size
- Type: integer
- Required
Total number of disks for PGs of this pool - i.e., number of replicas for
replicated pools and number of data plus parity disks for EC/XOR pools.
## parity_chunks
- Type: integer
Number of parity chunks for EC/XOR pools. For such pools, data will be lost
if you lose more than parity_chunks disks at once, so this parameter can be
equally described as FTT (number of failures to tolerate).
Required for EC/XOR pools, ignored for replicated pools.
## pg_minsize
- Type: integer
- Required
Number of available live disks for PGs of this pool to remain active.
That is, if it becomes impossible to place PG data on at least (pg_minsize)
OSDs, PG is deactivated for both read and write. So you know that a fresh
write always goes to at least (pg_minsize) OSDs (disks).
For example, the difference between pg_minsize 2 and 1 in a 3-way replicated
pool (pg_size=3) is:
- If 2 hosts go down with pg_minsize=2, the pool becomes inactive and remains
inactive for [osd_out_time](monitor.en.md#osd_out_time) (10 minutes). After
this timeout, the monitor selects replacement hosts/OSDs and the pool comes
up and starts to heal. Therefore, if you don't have replacement OSDs, i.e.
if you only have 3 hosts with OSDs and 2 of them are down, the pool remains
inactive until you add or return at least 1 host (or change failure_domain
to "osd").
- If 2 hosts go down with pg_minsize=1, the pool only experiences a short
I/O pause until the monitor notices that OSDs are down (5-10 seconds with
the default [etcd_report_interval](osd.en.md#etcd_report_interval)). After
this pause, I/O resumes, but new data is temporarily written in only 1 copy.
Then, after osd_out_time, the monitor also selects replacement OSDs and the
pool starts to heal.
So, pg_minsize regulates the number of failures that a pool can tolerate
without temporary downtime for [osd_out_time](monitor.en.md#osd_out_time),
but at a cost of slightly reduced storage reliability.
FIXME: pg_minsize behaviour may be changed in the future to only make PGs
read-only instead of deactivating them.
## pg_count
- Type: integer
- Required
Number of PGs for this pool. The value should be big enough for the monitor /
LP solver to be able to optimize data placement.
"Enough" is usually around 10-100 PGs per OSD, i.e. you set pg_count for pool
to (total OSD count * 10 / pg_size). You can round it to the closest power of 2,
because it makes it easier to reduce or increase PG count later by dividing or
multiplying it by 2.
In Vitastor, PGs are ephemeral, so you can change pool PG count anytime just
by overwriting pool configuration in etcd. Amount of the data affected by
rebalance will be smaller if the new PG count is a multiple of the old PG count
or vice versa.
## failure_domain
- Type: string
- Default: host
Failure domain specification. Must be "host" or "osd" or refer to one of the
placement tree levels, defined in [placement_levels](monitor.en.md#placement_levels).
Two replicas, or two parts in case of EC/XOR, of the same block of data are
never put on OSDs in the same failure domain (for example, on the same host).
So failure domain specifies the unit which failure you are protecting yourself
from.
## level_placement
- Type: string
Additional failure domain rules, applied in conjuction with failure_domain.
Must be specified in the following form:
`<placement level>=<sequence of characters>, <level2>=<sequence2>, ...`
Sequence should be exactly [pg_size](#pg_size) character long. Each character
corresponds to an OSD in the PG of this pool. Equal characters mean that
corresponding items of the PG should be placed into the same placement tree
item at this level. Different characters mean that items should be placed into
different items.
For example, if you want a EC 4+2 pool and you want every 2 chunks to be stored
in its own datacenter and you also want each chunk to be stored on a different
host, you should set `level_placement` to `dc=112233 host=123456`.
Or you can set `level_placement` to `dc=112233` and leave `failure_domain` empty,
because `host` is the default `failure_domain` and it will be applied anyway.
Without this rule, it may happen that 3 chunks will be stored on OSDs in the
same datacenter, and the data will become inaccessibly if that datacenter goes
down in this case.
Of course, you should group your hosts into datacenters before applying the rule
by setting [placement_levels](monitor.en.md#placement_levels) to something like
`{"dc":90,"host":100,"osd":110}` and add DCs to [node_placement](#placement-tree),
like `{"dc1":{"level":"dc"},"host1":{"parent":"dc1"},...}`.
## raw_placement
- Type: string
Raw PG placement rules, specified in the form of a DSL (domain-specific language).
Use only if you really know what you're doing :)
DSL specification:
```
dsl := item | item ("\n" | ",") items
item := "any" | rules
rules := rule | rule rules
rule := level operator arg
level := /\w+/
operator := "!=" | "=" | ">" | "?="
arg := value | "(" values ")"
values := value | value "," values
value := item_ref | constant_id
item_ref := /\d+/
constant_id := /"([^"]+)"/
```
"?=" operator means "preferred". I.e. `dc ?= "meow"` means "prefer datacenter meow
for this chunk, but put into another dc if it's unavailable".
Examples:
- Simple 3 replicas with failure_domain=host: `any, host!=1, host!=(1,2)`
- EC 4+2 in 3 DC: `any, dc=1 host!=1, dc!=1, dc=3 host!=3, dc!=(1,3), dc=5 host!=5`
- 1 replica in fixed DC + 2 in random DCs: `dc?=meow, dc!=1, dc!=(1,2)`
## max_osd_combinations
- Type: integer
- Default: 10000
Vitastor data placement algorithm is based on the LP solver and OSD combinations
which are fed to it are generated ramdonly. This parameter specifies the maximum
number of combinations to generate when optimising PG placement.
This parameter usually doesn't require to be changed.
## block_size
- Type: integer
- Default: 131072
Block size for this pool. The value from /vitastor/config/global is used when
unspecified. Only OSDs with matching block_size are used for each pool. If you
want to further restrict OSDs for the pool, use [osd_tags](#osd_tags).
Read more about this parameter in [Cluster-Wide Disk Layout Parameters](layout-cluster.en.md#block_size).
## bitmap_granularity
- Type: integer
- Default: 4096
"Sector" size of virtual disks in this pool. The value from /vitastor/config/global
is used when unspecified. Similarly to block_size, only OSDs with matching
bitmap_granularity are used for each pool.
Read more about this parameter in [Cluster-Wide Disk Layout Parameters](layout-cluster.en.md#bitmap_granularity).
## immediate_commit
- Type: string, one of "all", "small" and "none"
- Default: none
Immediate commit setting for this pool. The value from /vitastor/config/global
is used when unspecified. Similarly to block_size, only OSDs with compatible
bitmap_granularity are used for each pool. "Compatible" means that a pool with
non-immediate commit will use OSDs with immediate commit enabled, but not vice
versa. I.e., pools with "none" use all OSDs, pools with "small" only use OSDs
with "all" or "small", and pools with "all" only use OSDs with "all".
Read more about this parameter in [Cluster-Wide Disk Layout Parameters](layout-cluster.en.md#immediate_commit).
## pg_stripe_size
- Type: integer
- Default: 0
Specifies the stripe size for this pool according to which images are split into
different PGs. Stripe size can't be smaller than [block_size](layout-cluster.en.md#block_size)
multiplied by (pg_size - parity_chunks) for EC/XOR pools, or 1 for replicated pools,
and the same value is used by default.
This means first `pg_stripe_size = (block_size * (pg_size-parity_chunks))` bytes
of an image go to one PG, next `pg_stripe_size` bytes go to another PG and so on.
Usually doesn't require to be changed separately from the block size.
## root_node
- Type: string
Specifies the root node of the OSD tree to restrict this pool OSDs to.
Referenced root node must exist in /vitastor/config/node_placement.
## osd_tags
- Type: string or array of strings
Specifies OSD tags to restrict this pool to. If multiple tags are specified,
only OSDs having all of these tags will be used for this pool.
## primary_affinity_tags
- Type: string or array of strings
Specifies OSD tags to prefer putting primary OSDs in this pool to.
Note that for EC/XOR pools Vitastor always prefers to put primary OSD on one
of the OSDs containing a data chunk for a PG.
## scrub_interval
- Type: time interval (number + unit s/m/h/d/M/y)
Automatic scrubbing interval for this pool. Overrides
[global scrub_interval setting](osd.en.md#scrub_interval).
## used_for_fs
- Type: string
If non-empty, the pool is marked as used for VitastorFS with metadata stored
in block image (regular Vitastor volume) named as the value of this pool parameter.
When a pool is marked as used for VitastorFS, regular block volume creation in it
is disabled (vitastor-cli refuses to create images without --force) to protect
the user from block volume and FS file ID collisions and data loss.
[vitastor-nfs](../usage/nfs.ru.md), in its turn, refuses to use pools not marked
for the corresponding FS when starting. This also implies that you can use one
pool only for one VitastorFS.
The second thing that is disabled for VitastorFS pools is reporting per-inode space
usage statistics in etcd because a FS pool may store a very large number of files
and statistics for them all would take a lot of space in etcd.
# Examples
## Replicated pool
```
{
"1": {
"name":"testpool",
"scheme":"replicated",
"pg_size":2,
"pg_minsize":1,
"pg_count":256,
"failure_domain":"host"
}
}
```
## Erasure-coded pool
```
{
"2": {
"name":"ecpool",
"scheme":"ec",
"pg_size":3,
"parity_chunks":1,
"pg_minsize":2,
"pg_count":256,
"failure_domain":"host"
}
}
```

438
docs/config/pool.ru.md Normal file
View File

@ -0,0 +1,438 @@
[Документация](../../README-ru.md#документация) → [Конфигурация](../config.ru.md) → Конфигурация пулов
-----
[Read in English](pool.en.md)
# Конфигурация пулов
Настройки пулов задаются в ключе etcd `/vitastor/config/pools` в JSON-формате:
```
{
"<Численный ID>": {
"name": "<имя>",
...остальные параметры...
}
}
```
На настройку пулов также влияют:
- [Дерево размещения OSD](#дерево-размещения)
- [Настройки отдельных OSD](#настройки-osd)
Параметры:
- [name](#name)
- [scheme](#scheme)
- [pg_size](#pg_size)
- [parity_chunks](#parity_chunks)
- [pg_minsize](#pg_minsize)
- [pg_count](#pg_count)
- [failure_domain](#failure_domain)
- [level_placement](#level_placement)
- [raw_placement](#raw_placement)
- [max_osd_combinations](#max_osd_combinations)
- [block_size](#block_size)
- [bitmap_granularity](#bitmap_granularity)
- [immediate_commit](#immediate_commit)
- [pg_stripe_size](#pg_stripe_size)
- [root_node](#root_node)
- [osd_tags](#osd_tags)
- [primary_affinity_tags](#primary_affinity_tags)
- [scrub_interval](#scrub_interval)
- [used_for_fs](#used_for_fs)
Примеры:
- [Реплицированный пул](#реплицированный-пул)
- [Пул с кодами коррекции ошибок 2+1](#пул-с-кодами-коррекции-ошибок)
# Дерево размещения
Дерево размещения OSD задаётся в отдельном ключе etcd `/vitastor/config/node_placement`
в следующем JSON-формате:
`
{
"<имя узла или номер OSD>": {
"level": "<уровень>",
"parent": "<имя родительского узла, если есть>"
},
...
}
`
Здесь, если название узла - число, считается, что это OSD. Уровень OSD
всегда равен "osd" и не может быть переопределён. Для OSD вы можете только
переопределить родительский узел. По умолчанию родителем OSD считается его хост.
Нечисловые имена узлов относятся к другим узлам дерева OSD, таким, как хосты (серверы),
стойки, датацентры и так далее.
Хосты всех OSD автоматически создаются в дереве с уровнем "host" и именем, равным имени хоста,
сообщаемым соответствующим OSD. Вы можете ссылаться на эти хосты, не заводя их
в дереве вручную.
Уровень может быть "host", "osd" или относиться к другому уровню размещения из
[placement_levels](monitor.ru.md#placement_levels).
Родительский узел нужен только для промежуточных узлов дерева.
# Настройки OSD
Настройки отдельных OSD задаются в ключах etcd `/vitastor/config/osd/<number>`
в JSON-формате `{"<key>":<value>}`.
На данный момент поддерживаются следующие настройки:
- [reweight](#reweight)
- [tags](#tags)
- [noout](#noout)
## reweight
- Тип: число, от 0 до 1
- По умолчанию: 1
Каждый OSD получает число PG, пропорциональное его размеру. Reweight - это
множитель для размера, используемый в процессе распределения PG.
Это значит, что OSD, сконфигурированный с reweight меньше 1 будет получать
меньше PG, чем обычно. OSD с reweight, равным 0, не будет участвовать в
хранении данных вообще. Вы можете установить reweight в 0, чтобы убрать
все данные с OSD.
## tags
- Тип: строка или массив строк
Задаёт тег или набор тегов для данного OSD. Теги можно использовать, чтобы
делить OSD на множества и потом размещать пул только на части OSD, а не на
всех. Можно, например, пометить SSD OSD тегом "ssd", а HDD тегом "hdd", в
этом смысле теги работают аналогично классам устройств.
## noout
- Тип: булево (да/нет)
- Значение по умолчанию: false
Если установлено в true, то [osd_out_time](monitor.ru.md#osd_out_time) для этого
OSD игнорируется и OSD не удаляется из распределения данных монитором.
# Параметры
## name
- Тип: строка
- Обязательный
Название пула.
## scheme
- Тип: строка
- Обязательный
- Возможные значения: "replicated", "xor", "ec" или "jerasure"
Схема избыточности, используемая в данном пуле. "jerasure" - синоним для "ec",
в обеих схемах используются коды Рида-Соломона-Вандермонда, реализованные на
основе библиотек ISA-L или jerasure. Быстрая реализация на основе ISA-L
используется автоматически, когда доступна, в противном случае используется
более медленная jerasure-версия.
## pg_size
- Тип: целое число
- Обязательный
Размер PG данного пула, т.е. число реплик для реплицированных пулов или
число дисков данных плюс дисков чётности для пулов EC/XOR.
## parity_chunks
- Тип: целое число
Число дисков чётности для EC/XOR пулов. Иными словами, число дисков, при
одновременной потере которых данные будут потеряны.
Игнорируется для реплицированных пулов, обязательно для EC/XOR.
## pg_minsize
- Тип: целое число
- Обязательный
Число доступных дисков для PG данного пула, при котором PG остаются активны.
Если становится невозможно размещать новые данные в PG как минимум на pg_minsize
OSD, PG деактивируется на чтение и запись. Иными словами, всегда известно,
что новые блоки данных всегда записываются как минимум на pg_minsize дисков.
Для примера, разница между pg_minsize 2 и 1 в реплицированном пуле с 3 копиями
данных (pg_size=3), проявляется следующим образом:
- Если 2 сервера отключаются при pg_minsize=2, пул становится неактивным и
остаётся неактивным в течение [osd_out_time](monitor.ru.md#osd_out_time)
(10 минут), после чего монитор назначает другие OSD/серверы на замену, пул
поднимается и начинает восстанавливать недостающие копии данных. Соответственно,
если OSD на замену нет - то есть, если у вас всего 3 сервера с OSD и 2 из них
недоступны - пул так и остаётся недоступным до тех пор, пока вы не вернёте
или не добавите хотя бы 1 сервер (или не переключите failure_domain на "osd").
- Если 2 сервера отключаются при pg_minsize=1, ввод-вывод лишь приостанавливается
на короткое время, до тех пор, пока монитор не поймёт, что OSD отключены
(что занимает 5-10 секунд при стандартном [etcd_report_interval](osd.ru.md#etcd_report_interval)).
После этого ввод-вывод восстанавливается, но новые данные временно пишутся
всего в 1 копии. Когда же проходит osd_out_time, монитор точно так же назначает
другие OSD на замену выбывшим и пул начинает восстанавливать копии данных.
То есть, pg_minsize регулирует число отказов, которые пул может пережить без
временной остановки обслуживания на [osd_out_time](monitor.ru.md#osd_out_time),
но ценой немного пониженных гарантий надёжности.
FIXME: Поведение pg_minsize может быть изменено в будущем с полной деактивации
PG на перевод их в режим только для чтения.
## pg_count
- Тип: целое число
- Обязательный
Число PG для данного пула. Число должно быть достаточно большим, чтобы монитор
мог равномерно распределить по ним данные.
Обычно это означает примерно 10-100 PG на 1 OSD, т.е. pg_count можно устанавливать
равным (общему числу OSD * 10 / pg_size). Значение можно округлить до ближайшей
степени 2, чтобы потом было легче уменьшать или увеличивать число PG, умножая
или деля его на 2.
PG в Vitastor эферемерны, то есть вы можете менять их число в любой момент,
просто перезаписывая конфигурацию пулов в etcd. Однако объём перемещения данных
при этом будет минимален, если новое число PG кратно старому (или наоборот).
## failure_domain
- Тип: строка
- По умолчанию: host
Домен отказа для пула. Может быть равен "host" или "osd" или любому другому
уровню дерева OSD, задаваемому в настройке [placement_levels](monitor.ru.md#placement_levels).
Смысл домена отказа в том, что 2 копии, или 2 части одного блока данных в случае
кодов коррекции ошибок, никогда не помещаются на OSD, принадлежащие одному домену отказа.
Иными словами, домен отказа - это то, от отказа чего вы защищаете себя избыточным
хранением.
## level_placement
- Тип: строка
Правила дополнительных доменов отказа, применяемые вместе с failure_domain.
Должны задаваться в следующем виде:
`<уровень>=<последовательность символов>, <уровень2>=<последовательность2>, ...`
Каждая `<последовательность>` должна состоять ровно из [pg_size](#pg_size) символов.
Каждый символ соответствует одному OSD (размещению одной части PG) этого пула.
Одинаковые символы означают, что соответствующие части размещаются в один и тот же
узел дерева OSD на заданном `<уровне>`. Разные символы означают, что части
размещаются в разные узлы.
Например, если вы хотите сделать пул EC 4+2 и хотите поместить каждые 2 части
данных в свой датацентр, и также вы хотите, чтобы каждая часть размещалась на
другом хосте, то вы должны задать `level_placement` равным `dc=112233 host=123456`.
Либо вы просто можете задать `level_placement` равным `dc=112233` и оставить
`failure_domain` пустым, т.к. `host` это его значение по умолчанию и оно также
применится автоматически.
Без этого правила может получиться так, что в одном из датацентров окажется
3 части данных одной PG и данные окажутся недоступными при временном отключении
этого датацентра.
Естественно, перед установкой правила вам нужно сгруппировать ваши хосты в
датацентры, установив [placement_levels](monitor.ru.md#placement_levels) во что-то
типа `{"dc":90,"host":100,"osd":110}` и добавив датацентры в [node_placement](#дерево-размещения),
примерно так: `{"dc1":{"level":"dc"},"host1":{"parent":"dc1"},...}`.
## raw_placement
- Type: string
Низкоуровневые правила генерации PG в форме DSL (доменно-специфичного языка).
Используйте, только если действительно знаете, зачем вам это надо :)
Спецификация DSL:
```
dsl := item | item ("\n" | ",") items
item := "any" | rules
rules := rule | rule rules
rule := level operator arg
level := /\w+/
operator := "!=" | "=" | ">" | "?="
arg := value | "(" values ")"
values := value | value "," values
value := item_ref | constant_id
item_ref := /\d+/
constant_id := /"([^"]+)"/
```
Оператор "?=" означает "предпочитаемый". Т.е. `dc ?= "meow"` означает "предпочитать
датацентр meow для этой части данных, но разместить её в другом датацентре, если
meow недоступен".
Примеры:
- Простые 3 реплики с failure_domain=host: `any, host!=1, host!=(1,2)`
- EC 4+2 в 3 датацентрах: `any, dc=1 host!=1, dc!=1, dc=3 host!=3, dc!=(1,3), dc=5 host!=5`
- 1 копия в фиксированном ДЦ + 2 в других ДЦ: `dc?=meow, dc!=1, dc!=(1,2)`
## max_osd_combinations
- Тип: целое число
- По умолчанию: 10000
Алгоритм распределения данных Vitastor основан на решателе задачи линейного
программирования. При этом для снижения сложности задачи возможные комбинации OSD
генерируются случайно и ограничиваются количеством, равным значению этого параметра.
Обычно данный параметр не требует изменений.
## block_size
- Тип: целое число
- По умолчанию: 131072
Размер блока для данного пула. Если не задан, используется значение из
/vitastor/config/global. Если в вашем кластере есть OSD с разными размерами
блока, пул будет использовать только OSD с размером блока, равным размеру блока
пула. Если вы хотите сильнее ограничить набор используемых для пула OSD -
используйте [osd_tags](#osd_tags).
О самом параметре читайте в разделе [Дисковые параметры уровня кластера](layout-cluster.ru.md#block_size).
## bitmap_granularity
- Тип: целое число
- По умолчанию: 4096
Размер "сектора" виртуальных дисков в данном пуле. Если не задан, используется
значение из /vitastor/config/global. Аналогично block_size, каждый пул будет
использовать только OSD с совпадающей с пулом настройкой bitmap_granularity.
О самом параметре читайте в разделе [Дисковые параметры уровня кластера](layout-cluster.ru.md#bitmap_granularity).
## immediate_commit
- Тип: строка "all", "small" или "none"
- По умолчанию: none
Настройка мгновенного коммита для данного пула. Если не задана, используется
значение из /vitastor/config/global. Аналогично block_size, каждый пул будет
использовать только OSD с *совместимыми* настройками immediate_commit.
"Совместимыми" означает, что пул с отключенным мгновенным коммитом будет
использовать OSD с включённым мгновенным коммитом, но не наоборот. То есть,
пул со значением "none" будет использовать все OSD, пул со "small" будет
использовать OSD с "all" или "small", а пул с "all" будет использовать только
OSD с "all".
О самом параметре читайте в разделе [Дисковые параметры уровня кластера](layout-cluster.ru.md#immediate_commit).
## pg_stripe_size
- Тип: целое число
- По умолчанию: 0
Данный параметр задаёт размер полосы "нарезки" образов на PG. Размер полосы не может
быть меньше, чем [block_size](#block_size), умноженный на
(pg_size - parity_chunks) для EC-пулов или 1 для реплицированных пулов. То же
значение используется по умолчанию.
Это означает, что по умолчанию первые `pg_stripe_size = (block_size * (pg_size-parity_chunks))` байт
образа помещаются в одну PG, следующие `pg_stripe_size` байт помещаются в другую
и т.п.
Данный параметр обычно тоже не требует изменений.
## root_node
- Тип: строка
Корневой узел дерева OSD для ограничения OSD, выбираемых для пула. Задаваемый
узел должен быть предварительно задан в /vitastor/config/node_placement.
## osd_tags
- Тип: строка или массив строк
Теги OSD для ограничения OSD, выбираемых для пула. Если задаётся несколько тегов
массивом, то выбираются только OSD, у которых есть все эти теги.
## primary_affinity_tags
- Тип: строка или массив строк
Теги OSD, по которым должны выбираться OSD, предпочитаемые в качестве первичных
для PG этого пула. Имейте в виду, что для EC-пулов Vitastor также всегда
предпочитает помещать первичный OSD на один из OSD с данными, а не с чётностью.
## scrub_interval
- Тип: временной интервал (число + единица измерения s/m/h/d/M/y)
Интервал скраба, то есть, автоматической фоновой проверки данных для данного пула.
Переопределяет [глобальную настройку scrub_interval](osd.ru.md#scrub_interval).
## used_for_fs
- Type: string
Если непусто, пул помечается как используемый для файловой системы VitastorFS с
метаданными, хранимыми в блочном образе Vitastor с именем, равным значению
этого параметра.
Когда пул помечается как используемый для VitastorFS, создание обычных блочных
образов в нём отключается (vitastor-cli отказывается создавать образы без --force),
чтобы защитить пользователя от коллизий ID файлов и блочных образов и, таким
образом, от потери данных.
[vitastor-nfs](../usage/nfs.ru.md), в свою очередь, при запуске отказывается
использовать для ФС пулы, не выделенные для неё. Это также означает, что один
пул может использоваться только для одной VitastorFS.
Также для ФС-пулов отключается передача статистики в etcd по отдельным инодам,
так как ФС-пул может содержать очень много файлов и статистика по ним всем
заняла бы очень много места в etcd.
# Примеры
## Реплицированный пул
```
{
"1": {
"name":"testpool",
"scheme":"replicated",
"pg_size":2,
"pg_minsize":1,
"pg_count":256,
"failure_domain":"host"
}
}
```
## Пул с кодами коррекции ошибок
```
{
"2": {
"name":"ecpool",
"scheme":"ec",
"pg_size":3,
"parity_chunks":1,
"pg_minsize":2,
"pg_count":256,
"failure_domain":"host"
}
}
```

View File

@ -0,0 +1,4 @@
# Client Parameters
These parameters apply only to Vitastor clients (QEMU, fio, NBD and so on) and
affect their interaction with the cluster.

View File

@ -0,0 +1,4 @@
# Параметры клиентского кода
Данные параметры применяются только к клиентам Vitastor (QEMU, fio, NBD и т.п.) и
затрагивают логику их работы с кластером.

226
docs/config/src/client.yml Normal file
View File

@ -0,0 +1,226 @@
- name: client_retry_interval
type: ms
min: 10
default: 50
online: true
info: |
Retry time for I/O requests failed due to inactive PGs or network
connectivity errors.
info_ru: |
Время повтора запросов ввода-вывода, неудачных из-за неактивных PG или
ошибок сети.
- name: client_eio_retry_interval
type: ms
default: 1000
online: true
info: |
Retry time for I/O requests failed due to data corruption or unfinished
EC object deletions (has_incomplete PG state). 0 disables such retries
and clients are not blocked and just get EIO error code instead.
info_ru: |
Время повтора запросов ввода-вывода, неудачных из-за повреждения данных
или незавершённых удалений EC-объектов (состояния PG has_incomplete).
0 отключает повторы таких запросов и клиенты не блокируются, а вместо
этого просто получают код ошибки EIO.
- name: client_retry_enospc
type: bool
default: true
online: true
info: |
Retry writes on out of space errors to wait until some space is freed on
OSDs.
info_ru: |
Повторять запросы записи, завершившиеся с ошибками нехватки места, т.е.
ожидать, пока на OSD не освободится место.
- name: client_max_dirty_bytes
type: int
default: 33554432
online: true
info: |
Without [immediate_commit](layout-cluster.en.md#immediate_commit)=all this parameter sets the limit of "dirty"
(not committed by fsync) data allowed by the client before forcing an
additional fsync and committing the data. Also note that the client always
holds a copy of uncommitted data in memory so this setting also affects
RAM usage of clients.
info_ru: |
При работе без [immediate_commit](layout-cluster.ru.md#immediate_commit)=all - это лимит объёма "грязных" (не
зафиксированных fsync-ом) данных, при достижении которого клиент будет
принудительно вызывать fsync и фиксировать данные. Также стоит иметь в виду,
что в этом случае до момента fsync клиент хранит копию незафиксированных
данных в памяти, то есть, настройка влияет на потребление памяти клиентами.
- name: client_max_dirty_ops
type: int
default: 1024
online: true
info: |
Same as client_max_dirty_bytes, but instead of total size, limits the number
of uncommitted write operations.
info_ru: |
Аналогично client_max_dirty_bytes, но ограничивает количество
незафиксированных операций записи вместо их общего объёма.
- name: client_enable_writeback
type: bool
default: false
online: true
info: |
This parameter enables client-side write buffering. This means that write
requests are accumulated in memory for a short time before being sent to
a Vitastor cluster which allows to send them in parallel and increase
performance of some applications. Writes are buffered until client forces
a flush with fsync() or until the amount of buffered writes exceeds the
limit.
Write buffering significantly increases performance of some applications,
for example, CrystalDiskMark under Windows (LOL :-D), but also any other
applications if they do writes in one of two non-optimal ways: either if
they do a lot of small (4 kb or so) sequential writes, or if they do a lot
of small random writes, but without any parallelism or asynchrony, and also
without calling fsync().
With write buffering enabled, you can expect around 22000 T1Q1 random write
iops in QEMU more or less regardless of the quality of your SSDs, and this
number is in fact bound by QEMU itself rather than Vitastor (check it
yourself by adding a "driver=null-co" disk in QEMU). Without write
buffering, the current record is 9900 iops, but the number is usually
even lower with non-ideal hardware, for example, it may be 5000 iops.
Even when this parameter is enabled, write buffering isn't enabled until
the client explicitly allows it, because enabling it without the client
being aware of the fact that his writes may be buffered may lead to data
loss. Because of this, older versions of clients don't support write
buffering at all, newer versions of the QEMU driver allow write buffering
only if it's enabled in disk settings with `-blockdev cache.direct=false`,
and newer versions of FIO only allow write buffering if you don't specify
`-direct=1`. NBD and NFS drivers allow write buffering by default.
You can overcome this restriction too with the `client_writeback_allowed`
parameter, but you shouldn't do that unless you **really** know what you
are doing.
info_ru: |
Данный параметр разрешает включать буферизацию записи в памяти. Буферизация
означает, что операции записи отправляются на кластер Vitastor не сразу, а
могут небольшое время накапливаться в памяти и сбрасываться сразу пакетами,
до тех пор, пока либо не будет превышен лимит неотправленных записей, либо
пока клиент не вызовет fsync.
Буферизация значительно повышает производительность некоторых приложений,
например, CrystalDiskMark в Windows (ха-ха :-D), но также и любых других,
которые пишут на диск неоптимально: либо последовательно, но мелкими блоками
(например, по 4 кб), либо случайно, но без параллелизма и без fsync - то
есть, например, отправляя 128 операций записи в разные места диска, но не
все сразу с помощью асинхронного I/O, а по одной.
В QEMU с буферизацией записи можно ожидать показателя примерно 22000
операций случайной записи в секунду в 1 поток и с глубиной очереди 1 (T1Q1)
без fsync, почти вне зависимости от того, насколько хороши ваши диски - эта
цифра упирается в сам QEMU. Без буферизации рекорд пока что - 9900 операций
в секунду, но на железе похуже может быть и поменьше, например, 5000 операций
в секунду.
При этом, даже если данный параметр включён, буферизация не включается, если
явно не разрешена клиентом, т.к. если клиент не знает, что запросы записи
буферизуются, это может приводить к потере данных. Поэтому в старых версиях
клиентских драйверов буферизация записи не включается вообще, в новых
версиях QEMU-драйвера включается, только если разрешена опцией диска
`-blockdev cache.direct=false`, а в fio - только если нет опции `-direct=1`.
В NBD и NFS драйверах буферизация записи разрешена по умолчанию.
Можно обойти и это ограничение с помощью параметра `client_writeback_allowed`,
но делать так не надо, если только вы не уверены в том, что делаете, на все
100%. :-)
- name: client_max_buffered_bytes
type: int
default: 33554432
online: true
info: |
Maximum total size of buffered writes which triggers write-back when reached.
info_ru: |
Максимальный общий размер буферизованных записей, при достижении которого
начинается процесс сброса данных на сервер.
- name: client_max_buffered_ops
type: int
default: 1024
online: true
info: |
Maximum number of buffered writes which triggers write-back when reached.
Multiple consecutive modified data regions are counted as 1 write here.
info_ru: |
Максимальное количество буферизованных записей, при достижении которого
начинается процесс сброса данных на сервер. При этом несколько
последовательных изменённых областей здесь считаются 1 записью.
- name: client_max_writeback_iodepth
type: int
default: 256
online: true
info: |
Maximum number of parallel writes when flushing buffered data to the server.
info_ru: |
Максимальное число параллельных операций записи при сбросе буферов на сервер.
- name: nbd_timeout
type: sec
default: 300
online: false
info: |
Timeout for I/O operations for [NBD](../usage/nbd.en.md). If an operation
executes for longer than this timeout, including when your cluster is just
temporarily down for more than timeout, the NBD device will detach by itself
(and possibly break the mounted file system).
You can set timeout to 0 to never detach, but in that case you won't be
able to remove the kernel device at all if the NBD process dies - you'll have
to reboot the host.
info_ru: |
Таймаут для операций чтения/записи через [NBD](../usage/nbd.ru.md). Если
операция выполняется дольше таймаута, включая временную недоступность
кластера на время, большее таймаута, NBD-устройство отключится само собой
(и, возможно, сломает примонтированную ФС).
Вы можете установить таймаут в 0, чтобы никогда не отключать устройство по
таймауту, но в этом случае вы вообще не сможете удалить устройство, если
процесс NBD умрёт - вам придётся перезагружать сервер.
- name: nbd_max_devices
type: int
default: 64
online: false
info: |
Maximum number of NBD devices in the system. This value is passed as
`nbds_max` parameter for the nbd kernel module when vitastor-nbd autoloads it.
info_ru: |
Максимальное число NBD-устройств в системе. Данное значение передаётся
модулю ядра nbd как параметр `nbds_max`, когда его загружает vitastor-nbd.
- name: nbd_max_part
type: int
default: 3
online: false
info: |
Maximum number of partitions per NBD device. This value is passed as
`max_part` parameter for the nbd kernel module when vitastor-nbd autoloads it.
Note that (nbds_max)*(1+max_part) usually can't exceed 256.
info_ru: |
Максимальное число разделов на одном NBD-устройстве. Данное значение передаётся
модулю ядра nbd как параметр `max_part`, когда его загружает vitastor-nbd.
Имейте в виду, что (nbds_max)*(1+max_part) обычно не может превышать 256.
- name: osd_nearfull_ratio
type: float
default: 0.95
online: true
info: |
Ratio of used space on OSD to treat it as "almost full" in vitastor-cli status output.
Remember that some client writes may hang or complete with an error if even
just one OSD becomes 100 % full!
However, unlike in Ceph, 100 % full Vitastor OSDs don't crash (in Ceph they're
unable to start at all), so you'll be able to recover from "out of space" errors
without destroying and recreating OSDs.
info_ru: |
Доля занятого места на OSD, начиная с которой он считается "почти заполненным" в
выводе vitastor-cli status.
Помните, что часть клиентских запросов может зависнуть или завершиться с ошибкой,
если на 100 % заполнится хотя бы 1 OSD!
Однако, в отличие от Ceph, заполненные на 100 % OSD Vitastor не падают (в Ceph
заполненные на 100% OSD вообще не могут стартовать), так что вы сможете
восстановить работу кластера после ошибок отсутствия свободного места
без уничтожения и пересоздания OSD.

View File

@ -0,0 +1,3 @@
# Common Parameters
These are the most common parameters which apply to all components of Vitastor.

View File

@ -0,0 +1,3 @@
# Общие параметры
Это наиболее общие параметры, используемые всеми компонентами Vitastor.

View File

@ -0,0 +1,44 @@
- name: config_path
type: string
default: "/etc/vitastor/vitastor.conf"
info: |
Path to the JSON configuration file. Configuration file is optional,
a non-existing configuration file does not prevent Vitastor from
running if required parameters are specified.
info_ru: |
Путь к файлу конфигурации в формате JSON. Файл конфигурации необязателен,
без него Vitastor тоже будет работать, если переданы необходимые параметры.
- name: etcd_address
type: string or array of strings
type_ru: строка или массив строк
online: true
info: |
etcd connection endpoint(s). Multiple endpoints may be delimited by "," or
specified in a JSON array `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
Note that https is not supported for etcd connections yet.
etcd connection endpoints can be changed online by updating global
configuration in etcd itself - this allows to switch the cluster to new
etcd addresses without downtime.
info_ru: |
Адрес(а) подключения к etcd. Несколько адресов могут разделяться запятой
или указываться в виде JSON-массива `["10.0.115.10:2379/v3","10.0.115.11:2379/v3"]`.
Адреса подключения к etcd можно поменять на лету, обновив конфигурацию в
самом etcd - это позволяет переключить кластер на новые etcd без остановки.
- name: etcd_prefix
type: string
default: "/vitastor"
info: |
Prefix for all keys in etcd used by Vitastor. You can change prefix and, for
example, use a single etcd cluster for multiple Vitastor clusters.
info_ru: |
Префикс для ключей etcd, которые использует Vitastor. Вы можете задать другой
префикс, например, чтобы запустить несколько кластеров Vitastor с одним
кластером etcd.
- name: log_level
type: int
default: 0
online: true
info: Log level. Raise if you want more verbose output.
info_ru: Уровень логгирования. Повысьте, если хотите более подробный вывод.

145
docs/config/src/include.js Executable file
View File

@ -0,0 +1,145 @@
#!/usr/bin/nodejs
const fsp = require('fs').promises;
run(process.argv).catch(console.error);
async function run(argv)
{
if (argv.length < 3)
{
console.log('Markdown preprocessor\nUSAGE: ./include.js file.md');
return;
}
const index_file = await fsp.realpath(argv[2]);
const re = /(\{\{[\s\S]*?\}\}|\[[^\]]+\]\([^\)]+\)|(?:^|\n)#[^\n]+)/;
let text = await fsp.readFile(index_file, { encoding: 'utf-8' });
text = text.split(re);
let included = {};
let heading = 0, heading_name = '', m;
for (let i = 0; i < text.length; i++)
{
if (text[i].substr(0, 2) == '{{')
{
// Inclusion
let incfile = text[i].substr(2, text[i].length-4);
let section = null;
let indent = heading;
incfile = incfile.replace(/\s*\|\s*indent\s*=\s*(-?\d+)\s*$/, (m, m1) => { indent = parseInt(m1); return ''; });
incfile = incfile.replace(/\s*#\s*([^#]+)$/, (m, m1) => { section = m1; return ''; });
let inc_heading = section;
incfile = rel2abs(index_file, incfile);
let inc = await fsp.readFile(incfile, { encoding: 'utf-8' });
inc = inc.trim().replace(/^[\s\S]+?\n#/, '#'); // remove until the first header
inc = inc.split(re);
const indent_str = new Array(indent+1).join('#');
let section_start = -1, section_end = -1;
for (let j = 0; j < inc.length; j++)
{
if ((m = /^(\n?)(#+\s*)([\s\S]+)$/.exec(inc[j])))
{
if (!inc_heading)
{
inc_heading = m[3].trim();
}
if (section)
{
if (m[3].trim() == section)
section_start = j;
else if (section_start >= 0)
{
section_end = j;
break;
}
}
inc[j] = m[1] + indent_str + m[2] + m[3];
}
else if ((m = /^(\[[^\]]+\]\()([^\)]+)(\))$/.exec(inc[j])) && !/^https?:(\/\/)|^#/.exec(m[2]))
{
const abs_m2 = rel2abs(incfile, m[2]);
const rel_m = abs2rel(__filename, abs_m2);
if (rel_m.substr(0, 9) == '../../../') // outside docs
inc[j] = m[1] + 'https://git.yourcmc.ru/vitalif/vitastor/src/branch/master/'+rel2abs('docs/config/src/include.js', rel_m) + m[3];
else
inc[j] = m[1] + abs_m2 + m[3];
}
}
if (section)
{
inc = section_start >= 0 ? inc.slice(section_start, section_end < 0 ? inc.length : section_end) : [];
}
if (inc.length)
{
if (!inc_heading)
inc_heading = heading_name||'';
included[incfile+(section ? '#'+section : '')] = '#'+inc_heading.toLowerCase().replace(/\P{L}+/ug, '-').replace(/^-|-$/g, '');
inc[0] = inc[0].replace(/^\s+/, '');
inc[inc.length-1] = inc[inc.length-1].replace(/\s+$/, '');
}
text.splice(i, 1, ...inc);
i = i + inc.length - 1;
}
else if ((m = /^\n?(#+)\s*([\s\S]+)$/.exec(text[i])))
{
// Heading
heading = m[1].length;
heading_name = m[2].trim();
}
}
for (let i = 0; i < text.length; i++)
{
if ((m = /^(\[[^\]]+\]\()([^\)]+)(\))$/.exec(text[i])) && !/^https?:(\/\/)|^#/.exec(m[2]))
{
const p = m[2].indexOf('#');
if (included[m[2]])
{
text[i] = m[1]+included[m[2]]+m[3];
}
else if (p >= 0 && included[m[2].substr(0, p)])
{
text[i] = m[1]+m[2].substr(p)+m[3];
}
}
}
console.log(text.join(''));
}
function rel2abs(ref, rel)
{
rel = [ ...ref.replace(/^(.*)\/[^\/]+$/, '$1').split(/\/+/), ...rel.split(/\/+/) ];
return killdots(rel).join('/');
}
function abs2rel(ref, abs)
{
ref = ref.split(/\/+/);
abs = abs.split(/\/+/);
while (ref.length > 1 && ref[0] == abs[0])
{
ref.shift();
abs.shift();
}
for (let i = 1; i < ref.length; i++)
{
abs.unshift('..');
}
return killdots(abs).join('/');
}
function killdots(rel)
{
for (let i = 0; i < rel.length; i++)
{
if (rel[i] == '.')
{
rel.splice(i, 1);
i--;
}
else if (i >= 1 && rel[i] == '..' && rel[i-1] != '..')
{
rel.splice(i-1, 2);
i -= 2;
}
}
return rel;
}

View File

@ -0,0 +1,71 @@
# Vitastor
{{../../../README.md#The Idea}}
{{../../../README.md#Talks and presentations}}
{{../../intro/features.en.md}}
{{../../intro/quickstart.en.md}}
{{../../intro/architecture.en.md}}
## Installation
{{../../installation/packages.en.md}}
{{../../installation/proxmox.en.md}}
{{../../installation/openstack.en.md}}
{{../../installation/kubernetes.en.md}}
{{../../installation/source.en.md}}
{{../../config.en.md|indent=1}}
{{../../config/common.en.md|indent=2}}
{{../../config/network.en.md|indent=2}}
{{../../config/client.en.md|indent=2}}
{{../../config/layout-cluster.en.md|indent=2}}
{{../../config/layout-osd.en.md|indent=2}}
{{../../config/osd.en.md|indent=2}}
{{../../config/monitor.en.md|indent=2}}
{{../../config/pool.en.md|indent=2}}
{{../../config/inode.en.md|indent=2}}
## Usage
{{../../usage/cli.en.md}}
{{../../usage/disk.en.md}}
{{../../usage/fio.en.md}}
{{../../usage/nbd.en.md}}
{{../../usage/qemu.en.md}}
{{../../usage/nfs.en.md}}
{{../../usage/admin.en.md}}
## Performance
{{../../performance/understanding.en.md}}
{{../../performance/theoretical.en.md}}
{{../../performance/comparison1.en.md}}
{{../../performance/bench2.en.md}}
{{../../intro/author.en.md|indent=1}}

View File

@ -0,0 +1,71 @@
# Vitastor
{{../../../README-ru.md#Идея|indent=0}}
{{../../../README-ru.md#Презентации и записи докладов|indent=0}}
{{../../intro/features.ru.md}}
{{../../intro/quickstart.ru.md}}
{{../../intro/architecture.ru.md}}
## Установка
{{../../installation/packages.ru.md}}
{{../../installation/proxmox.ru.md}}
{{../../installation/openstack.ru.md}}
{{../../installation/kubernetes.ru.md}}
{{../../installation/source.ru.md}}
{{../../config.ru.md|indent=1}}
{{../../config/common.ru.md|indent=2}}
{{../../config/network.ru.md|indent=2}}
{{../../config/client.ru.md|indent=2}}
{{../../config/layout-cluster.ru.md|indent=2}}
{{../../config/layout-osd.ru.md|indent=2}}
{{../../config/osd.ru.md|indent=2}}
{{../../config/monitor.ru.md|indent=2}}
{{../../config/pool.ru.md|indent=2}}
{{../../config/inode.ru.md|indent=2}}
## Использование
{{../../usage/cli.ru.md}}
{{../../usage/disk.ru.md}}
{{../../usage/fio.ru.md}}
{{../../usage/nbd.ru.md}}
{{../../usage/qemu.ru.md}}
{{../../usage/nfs.ru.md}}
{{../../usage/admin.ru.md}}
## Производительность
{{../../performance/understanding.ru.md}}
{{../../performance/theoretical.ru.md}}
{{../../performance/comparison1.ru.md}}
{{../../performance/bench2.ru.md}}
{{../../intro/author.ru.md|indent=1}}

View File

@ -0,0 +1,14 @@
# Cluster-Wide Disk Layout Parameters
These parameters apply to clients and OSDs, are fixed at the moment of OSD drive
initialization and can't be changed after it without losing data.
OSDs with different values of these parameters (for example, SSD and SSD+HDD
OSDs) can coexist in one Vitastor cluster within different pools. Each pool can
only include OSDs with identical settings of these parameters.
These parameters, when set to a non-default value, must also be specified in
etcd for clients to be aware of their values, either in /vitastor/config/global
or in pool configuration. Pool configuration overrides the global setting.
If the value for a pool in etcd doesn't match on-disk OSD configuration, the
OSD will refuse to start PGs of that pool.

View File

@ -0,0 +1,14 @@
# Дисковые параметры уровня кластера
Данные параметры используются клиентами и OSD, задаются в момент инициализации
диска OSD и не могут быть изменены после этого без потери данных.
OSD с разными значениями данных параметров (например, SSD и гибридные SSD+HDD
OSD) могут сосуществовать в одном кластере Vitastor в разных пулах. Один пул
может включать только OSD с одинаковыми настройками этих параметров.
Данные параметры, отличаясь от значения по умолчанию, должны также быть заданы
в etcd, чтобы клиенты могли узнать их значение, либо в глобальной конфигурации
/vitastor/config/global, либо в настройках пулов. Настройки пула переопределяют
глобальное значение. Если значение в настройках пула не будет соответствовать
конфигурации OSD, OSD откажется запускать PG данного пула.

View File

@ -0,0 +1,153 @@
- name: block_size
type: int
default: 131072
info: |
Size of objects (data blocks) into which all physical and virtual drives
(within a pool) are subdivided in Vitastor. One of current main settings
in Vitastor, affects memory usage, write amplification and I/O load
distribution effectiveness.
Recommended default block size is 128 KB for SSD and 1 MB for HDD. In fact,
it's possible to use 1 MB for SSD too - it will lower memory usage, but
may increase average WA and reduce linear performance.
OSD memory usage is roughly (SIZE / BLOCK * 68 bytes) which is roughly
544 MB per 1 TB of used disk space with the default 128 KB block size.
With 1 MB it's 8 times lower.
info_ru: |
Размер объектов (блоков данных), на которые делятся физические и виртуальные
диски в Vitastor (в рамках каждого пула). Одна из ключевых на данный момент
настроек, влияет на потребление памяти, объём избыточной записи (write
amplification) и эффективность распределения нагрузки по OSD.
Рекомендуемые по умолчанию размеры блока - 128 килобайт для SSD и 1 мегабайт
для HDD. В принципе, для SSD можно тоже использовать блок размером 1 мегабайт,
это понизит использование памяти, но ухудшит распределение нагрузки и в
среднем увеличит WA.
Потребление памяти OSD составляет примерно (РАЗМЕР / БЛОК * 68 байт),
т.е. примерно 544 МБ памяти на 1 ТБ занятого места на диске при
стандартном 128 КБ блоке. При 1 МБ блоке памяти нужно в 8 раз меньше.
- name: bitmap_granularity
type: int
default: 4096
info: |
Required virtual disk write alignment ("sector size"). Must be a multiple
of disk_alignment. It's called bitmap granularity because Vitastor tracks
an allocation bitmap for each object containing 2 bits per each
(bitmap_granularity) bytes.
Can't be smaller than the OSD data device sector.
info_ru: |
Требуемое выравнивание записи на виртуальные диски (размер их "сектора").
Должен быть кратен disk_alignment. Называется гранулярностью битовой карты
потому, что Vitastor хранит битовую карту для каждого объекта, содержащую
по 2 бита на каждые (bitmap_granularity) байт.
Не может быть меньше размера сектора дисков данных OSD.
- name: immediate_commit
type: string
default: false
info: |
Another parameter which is really important for performance.
Desktop SSDs are very fast (100000+ iops) for simple random writes
without cache flush. However, they are really slow (only around 1000 iops)
if you try to fsync() each write, that is, when you want to guarantee that
each change gets immediately persisted to the physical media.
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
fast with and without fsync because their cache is protected from sudden
power loss by a built-in supercapacitor-based "UPS".
Some software-defined storage systems always fsync each write and thus are
really slow when used with desktop SSDs. Vitastor, however, can also
efficiently utilize desktop SSDs by postponing fsync until the client calls
it explicitly.
This is what this parameter regulates. When it's set to "all" the whole
Vitastor cluster commits each change to disks immediately and clients just
ignore fsyncs because they know for sure that they're unneeded. This reduces
the amount of network roundtrips performed by clients and improves
performance. So it's always better to use server grade SSDs with
supercapacitors even with Vitastor, especially given that they cost only
a bit more than desktop models.
There is also a common SATA SSD (and HDD too!) firmware bug (or feature)
that makes server SSDs which have supercapacitors slow with fsync. To check
if your SSDs are affected, compare benchmark results from `fio -name=test
-ioengine=libaio -direct=1 -bs=4k -rw=randwrite -iodepth=1` with and without
`-fsync=1`. Results should be the same. If fsync=1 result is worse you can
try to work around this bug by "disabling" drive write-back cache by running
`hdparm -W 0 /dev/sdXX` or `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
(IMPORTANT: don't mistake it with `/sys/block/sdXX/queue/write_cache` - it's
unsafe to change by hand). The same may apply to newer HDDs with internal
SSD cache or "media-cache" - for example, a lot of Seagate EXOS drives have
it (they have internal SSD cache even though it's not stated in datasheets).
Setting this parameter to "all" or "small" in OSD parameters requires enabling
[disable_journal_fsync](layout-osd.en.yml#disable_journal_fsync) and
[disable_meta_fsync](layout-osd.en.yml#disable_meta_fsync), setting it to
"all" also requires enabling [disable_data_fsync](layout-osd.en.yml#disable_data_fsync).
TLDR: For optimal performance, set immediate_commit to "all" if you only use
SSDs with supercapacitor-based power loss protection (nonvolatile
write-through cache) for both data and journals in the whole Vitastor
cluster. Set it to "small" if you only use such SSDs for journals. Leave
empty if your drives have write-back cache.
info_ru: |
Ещё один важный для производительности параметр.
Модели SSD для настольных компьютеров очень быстрые (100000+ операций в
секунду) при простой случайной записи без сбросов кэша. Однако они очень
медленные (всего порядка 1000 iops), если вы пытаетесь сбрасывать кэш после
каждой записи, то есть, если вы пытаетесь гарантировать, что каждое
изменение физически записывается в энергонезависимую память.
С другой стороны, серверные SSD с конденсаторами - функцией, называемой
"Advanced/Enhanced Power Loss Protection" или просто "Supercapacitor-based
Power Loss Protection" - одинаково быстрые и со сбросом кэша, и без
него, потому что их кэш защищён от потери питания встроенным "источником
бесперебойного питания" на основе суперконденсаторов и на самом деле они
его никогда не сбрасывают.
Некоторые программные СХД всегда сбрасывают кэши дисков при каждой записи
и поэтому работают очень медленно с настольными SSD. Vitastor, однако, может
откладывать fsync до явного его вызова со стороны клиента и таким образом
эффективно утилизировать настольные SSD.
Данный параметр влияет как раз на это. Когда он установлен в значение "all",
весь кластер Vitastor мгновенно фиксирует каждое изменение на физические
носители и клиенты могут просто игнорировать запросы fsync, т.к. они точно
знают, что fsync-и не нужны. Это уменьшает число необходимых обращений к OSD
по сети и улучшает производительность. Поэтому даже с Vitastor лучше всегда
использовать только серверные модели SSD с суперконденсаторами, особенно
учитывая то, что стоят они ненамного дороже настольных.
Также в прошивках SATA SSD (и даже HDD!) очень часто встречается либо баг,
либо просто особенность логики, из-за которой серверные SSD, имеющие
конденсаторы и защиту от потери питания, всё равно медленно работают с
fsync. Чтобы понять, подвержены ли этой проблеме ваши SSD, сравните
результаты тестов `fio -name=test -ioengine=libaio -direct=1 -bs=4k
-rw=randwrite -iodepth=1` без и с опцией `-fsync=1`. Результаты должны
быть одинаковые. Если результат с `fsync=1` хуже, вы можете попробовать
обойти проблему, "отключив" кэш записи диска командой `hdparm -W 0 /dev/sdXX`
либо `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
(ВАЖНО: не перепутайте с `/sys/block/sdXX/queue/write_cache` - этот параметр
менять руками небезопасно). Такая же проблема может встречаться и в новых
HDD-дисках с внутренним SSD или "медиа" кэшем - например, она встречается во
многих дисках Seagate EXOS (у них есть внутренний SSD-кэш, хотя это и не
указано в спецификациях).
Указание "all" или "small" в настройках / командной строке OSD требует
включения [disable_journal_fsync](layout-osd.ru.yml#disable_journal_fsync) и
[disable_meta_fsync](layout-osd.ru.yml#disable_meta_fsync), значение "all"
также требует включения [disable_data_fsync](layout-osd.ru.yml#disable_data_fsync).
Итого, вкратце: для оптимальной производительности установите
immediate_commit в значение "all", если вы используете в кластере только SSD
с суперконденсаторами и для данных, и для журналов. Если вы используете
такие SSD для всех журналов, но не для данных - можете установить параметр
в "small". Если и какие-то из дисков журналов имеют волатильный кэш записи -
оставьте параметр пустым.

View File

@ -0,0 +1,4 @@
# OSD Disk Layout Parameters
These parameters apply to OSDs, are fixed at the moment of OSD drive
initialization and can't be changed after it without losing data.

View File

@ -0,0 +1,5 @@
# Дисковые параметры OSD
Данные параметры используются только OSD и, также как и общекластерные
дисковые параметры, задаются в момент инициализации дисков OSD и не могут быть
изменены после этого без потери данных.

View File

@ -0,0 +1,276 @@
- name: data_device
type: string
info: |
Path to the block device to use for data. It's highly recommendded to use
stable paths for all device names: `/dev/disk/by-partuuid/xxx...` instead
of just `/dev/sda` or `/dev/nvme0n1` to not mess up after server restart.
Files can also be used instead of block devices, but this is implemented
only for testing purposes and not for production.
info_ru: |
Путь к диску (блочному устройству) для хранения данных. Крайне рекомендуется
использовать стабильные пути: `/dev/disk/by-partuuid/xxx...` вместо простых
`/dev/sda` или `/dev/nvme0n1`, чтобы пути не могли спутаться после
перезагрузки сервера. Также вместо блочных устройств можно указывать файлы,
но это реализовано только для тестирования, а не для боевой среды.
- name: meta_device
type: string
info: |
Path to the block device to use for the metadata. Metadata must be on a fast
SSD or performance will suffer. If this option is skipped, `data_device` is
used for the metadata.
info_ru: |
Путь к диску метаданных. Метаданные должны располагаться на быстром
SSD-диске, иначе производительность пострадает. Если эта опция не указана,
для метаданных используется `data_device`.
- name: journal_device
type: string
info: |
Path to the block device to use for the journal. Journal must be on a fast
SSD or performance will suffer. If this option is skipped, `meta_device` is
used for the journal, and if it's also empty, journal is put on
`data_device`. It's almost always fine to put metadata and journal on the
same device, in this case you only need to set `meta_device`.
info_ru: |
Путь к диску журнала. Журнал должен располагаться на быстром SSD-диске,
иначе производительность пострадает. Если эта опция не указана,
для журнала используется `meta_device`, если же пуста и она, журнал
располагается на `data_device`. Нормально располагать журнал и метаданные
на одном устройстве, в этом случае достаточно указать только `meta_device`.
- name: journal_offset
type: int
default: 0
info: Offset on the device in bytes where the journal is stored.
info_ru: Смещение на устройстве в байтах, по которому располагается журнал.
- name: journal_size
type: int
info: |
Journal size in bytes. By default, all available space between journal_offset
and data_offset, meta_offset or the end of the journal device is used.
Large journals aren't needed in SSD-only setups, 32 MB is always enough.
In SSD+HDD setups it is beneficial to use larger journals (for example, 1 GB)
and enable [throttle_small_writes](osd.en.md#throttle_small_writes).
info_ru: |
Размер журнала в байтах. По умолчанию для журнала используется всё доступное
место между journal_offset и data_offset, meta_offset или концом диска.
В SSD-кластерах большие журналы не нужны, достаточно 32 МБ. В гибридных
(SSD+HDD) кластерах осмысленно использовать больший размер журнал (например, 1 ГБ)
и включить [throttle_small_writes](osd.ru.md#throttle_small_writes).
- name: meta_offset
type: int
default: 0
info: |
Offset on the device in bytes where the metadata area is stored.
Again, set it to something if you colocate metadata with journal or data.
info_ru: |
Смещение на устройстве в байтах, по которому располагаются метаданные.
Эту опцию нужно задать, если метаданные у вас хранятся на том же
устройстве, что данные или журнал.
- name: data_offset
type: int
default: 0
info: |
Offset on the device in bytes where the data area is stored.
Again, set it to something if you colocate data with journal or metadata.
info_ru: |
Смещение на устройстве в байтах, по которому располагаются данные.
Эту опцию нужно задать, если данные у вас хранятся на том же
устройстве, что метаданные или журнал.
- name: data_size
type: int
info: |
Data area size in bytes. By default, the whole data device up to the end
will be used for the data area, but you can restrict it if you want to use
a smaller part. Note that there is no option to set metadata area size -
it's derived from the data area size.
info_ru: |
Размер области данных в байтах. По умолчанию под данные будет использована
вся доступная область устройства данных до конца устройства, но вы можете
использовать эту опцию, чтобы ограничить её меньшим размером. Заметьте, что
опции размера области метаданных нет - она вычисляется из размера области
данных автоматически.
- name: meta_block_size
type: int
default: 4096
info: |
Physical block size of the metadata device. 4096 for most current
HDDs and SSDs.
info_ru: |
Размер физического блока устройства метаданных. 4096 для большинства
современных SSD и HDD.
- name: journal_block_size
type: int
default: 4096
info: |
Physical block size of the journal device. Must be a multiple of
`disk_alignment`. 4096 for most current HDDs and SSDs.
info_ru: |
Размер физического блока устройства журнала. Должен быть кратен
`disk_alignment`. 4096 для большинства современных SSD и HDD.
- name: disable_data_fsync
type: bool
default: false
info: |
Do not issue fsyncs to the data device, i.e. do not flush its cache.
Safe ONLY if your data device has write-through cache. If you disable
the cache yourself using `hdparm` or `scsi_disk/cache_type` then make sure
that the cache disable command is run every time before starting Vitastor
OSD, for example, in the systemd unit. See also `immediate_commit` option
for the instructions to disable cache and how to benefit from it.
info_ru: |
Не отправлять fsync-и устройству данных, т.е. не сбрасывать его кэш.
Безопасно, ТОЛЬКО если ваше устройство данных имеет кэш со сквозной
записью (write-through). Если вы отключаете кэш через `hdparm` или
`scsi_disk/cache_type`, то удостоверьтесь, что команда отключения кэша
выполняется перед каждым запуском Vitastor OSD, например, в systemd unit-е.
Смотрите также опцию `immediate_commit` для инструкций по отключению кэша
и о том, как из этого извлечь выгоду.
- name: disable_meta_fsync
type: bool
default: false
info: |
Same as disable_data_fsync, but for the metadata device. If the metadata
device is not set or if the data device is used for the metadata the option
is ignored and disable_data_fsync value is used instead of it.
info_ru: |
То же, что disable_data_fsync, но для устройства метаданных. Если устройство
метаданных не задано или если оно равно устройству данных, значение опции
игнорируется и вместо него используется значение опции disable_data_fsync.
- name: disable_journal_fsync
type: bool
default: false
info: |
Same as disable_data_fsync, but for the journal device. If the journal
device is not set or if the metadata device is used for the journal the
option is ignored and disable_meta_fsync value is used instead of it. If
the same device is used for data, metadata and journal the option is also
ignored and disable_data_fsync value is used instead of it.
info_ru: |
То же, что disable_data_fsync, но для устройства журнала. Если устройство
журнала не задано или если оно равно устройству метаданных, значение опции
игнорируется и вместо него используется значение опции disable_meta_fsync.
Если одно и то же устройство используется и под данные, и под журнал, и под
метаданные - значение опции также игнорируется и вместо него используется
значение опции disable_data_fsync.
- name: disable_device_lock
type: bool
default: false
info: |
Do not lock data, metadata and journal block devices exclusively with
flock(). Though it's not recommended, but you can use it you want to run
multiple OSD with a single device and different offsets, without using
partitions.
info_ru: |
Не блокировать устройства данных, метаданных и журнала от открытия их
другими OSD с помощью flock(). Так делать не рекомендуется, но теоретически
вы можете это использовать, чтобы запускать несколько OSD на одном
устройстве с разными смещениями и без использования разделов.
- name: disk_alignment
type: int
default: 4096
info: |
Required physical disk write alignment. Most current SSD and HDD drives
use 4 KB physical sectors even if they report 512 byte logical sector
size, so 4 KB is a good default setting.
Note, however, that physical sector size also affects WA, because with block
devices it's impossible to write anything smaller than a block. So, when
Vitastor has to write a single metadata entry that's only about 32 bytes in
size, it actually has to write the whole 4 KB sector.
Because of this it can actually be beneficial to use SSDs which work well
with 512 byte sectors and use 512 byte disk_alignment, journal_block_size
and meta_block_size. But the only SSD that may fit into this category is
Intel Optane (probably, not tested yet).
Clients don't need to be aware of disk_alignment, so it's not required to
put a modified value into etcd key /vitastor/config/global.
info_ru: |
Требуемое выравнивание записи на физические диски. Почти все современные
SSD и HDD диски используют 4 КБ физические секторы, даже если показывают
логический размер сектора 512 байт, поэтому 4 КБ - хорошее значение по
умолчанию.
Однако стоит понимать, что физический размер сектора тоже влияет на
избыточную запись (WA), потому что ничего меньше блока (сектора) на блочное
устройство записать невозможно. Таким образом, когда Vitastor-у нужно
записать на диск всего лишь одну 32-байтную запись метаданных, фактически
приходится перезаписывать 4 КБ сектор целиком.
Поэтому, на самом деле, может быть выгодно найти SSD, хорошо работающие с
меньшими, 512-байтными, блоками и использовать 512-байтные disk_alignment,
journal_block_size и meta_block_size. Однако единственные SSD, которые
теоретически могут попасть в эту категорию - это Intel Optane (но и это
пока не проверялось автором).
Клиентам не обязательно знать про disk_alignment, так что помещать значение
этого параметра в etcd в /vitastor/config/global не нужно.
- name: data_csum_type
type: string
default: none
info: |
Data checksum type to use. May be "crc32c" or "none". Set to "crc32c" to
enable data checksums.
info_ru: |
Тип используемых OSD контрольных сумм данных. Может быть "crc32c" или "none".
Установите в "crc32c", чтобы включить расчёт и проверку контрольных сумм данных.
Следует понимать, что контрольные суммы в зависимости от размера блока их
расчёта либо увеличивают потребление памяти, либо снижают производительность.
Подробнее смотрите в описании параметра [csum_block_size](#csum_block_size).
- name: csum_block_size
type: int
default: 4096
info: |
Checksum calculation block size.
Must be equal or a multiple of [bitmap_granularity](layout-cluster.en.md#bitmap_granularity)
(which is usually 4 KB).
Checksums increase metadata size by 4 bytes per each csum_block_size of data.
Checksums are always a tradeoff:
1. You either sacrifice +1 GB RAM per 1 TB of data
2. Or you raise csum_block_size, for example, to 32k and sacrifice
50% random write iops due to checksum read-modify-write
3. Or you turn off [inmemory_metadata](osd.en.md#inmemory_metadata) and
sacrifice 50% random read iops due to checksum reads
All-flash clusters usually have enough RAM to use default csum_block_size,
which uses 1 GB RAM per 1 TB of data. HDD clusters usually don't.
Thus, recommended setups are:
1. All-flash, 1 GB RAM per 1 TB data: default (csum_block_size=4k)
2. All-flash, less RAM: csum_block_size=4k + inmemory_metadata=false
3. Hybrid HDD+SSD: csum_block_size=4k + inmemory_metadata=false
4. HDD-only, faster random read: csum_block_size=32k
5. HDD-only, faster random write: csum_block_size=4k +
inmemory_metadata=false + meta_io=cached
See also [meta_io](osd.en.md#meta_io).
info_ru: |
Размер блока расчёта контрольных сумм.
Должен быть равен или кратен [bitmap_granularity](layout-cluster.ru.md#bitmap_granularity)
(который обычно равен 4 КБ).
Контрольные суммы увеличивают размер метаданных на 4 байта на каждые
csum_block_size данных.
Контрольные суммы - это всегда компромисс:
1. Вы либо жертвуете потреблением +1 ГБ памяти на 1 ТБ дискового пространства
2. Либо вы повышаете csum_block_size до, скажем, 32k и жертвуете 50%
скорости случайной записи из-за цикла чтения-изменения-записи для расчёта
новых контрольных сумм
3. Либо вы отключаете [inmemory_metadata](osd.ru.md#inmemory_metadata) и
жертвуете 50% скорости случайного чтения из-за чтения контрольных сумм
с диска
Таким образом, рекомендуются следующие варианты настроек:
1. All-flash, 1 ГБ памяти на 1 ТБ данных: по умолчанию (csum_block_size=4k)
2. All-flash, меньше памяти: csum_block_size=4k + inmemory_metadata=false
3. Гибридные HDD+SSD: csum_block_size=4k + inmemory_metadata=false
4. Только HDD, быстрее случайное чтение: csum_block_size=32k
5. Только HDD, быстрее случайная запись: csum_block_size=4k +
inmemory_metadata=false + meta_io=cached
Смотрите также [meta_io](osd.ru.md#meta_io).

Some files were not shown because too many files have changed in this diff Show More