# Vitastor's Theoretical Maximum Performance
|
|
|
|
Replicated setups:
|
|
- Single-threaded (T1Q1) read latency: 1 network roundtrip + 1 disk read.
|
|
- Single-threaded write+fsync latency:
|
|
- With immediate commit: 2 network roundtrips + 1 disk write.
|
|
- With lazy commit: 4 network roundtrips + 1 disk write + 1 disk flush.
|
|
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
|
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops / number of replicas / write amplification)).
|
|
|
|
EC/XOR setups:
|
|
- Single-threaded (T1Q1) read latency: 1.5 network roundtrips + 1 disk read.
|
|
- Single-threaded write+fsync latency:
|
|
- With immediate commit: 3.5 network roundtrips + 1 disk read + 2 disk writes.
|
|
- With lazy commit: 5.5 network roundtrips + 1 disk read + 2 disk writes + 2 disk fsyncs.
|
|
- 0.5 in actually (k-1)/k which means that an additional roundtrip doesn't happen when
|
|
the read sub-operation can be served locally.
|
|
- Saturated parallel read iops: min(network bandwidth, sum(disk read iops)).
|
|
- Saturated parallel write iops: min(network bandwidth, sum(disk write iops * number of data drives / (number of data + parity drives) / write amplification)).
|
|
In fact, you should put disk write iops under the condition of ~10% reads / ~90% writes in this formula.
|
|
|
|
Write amplification for 4 KB blocks is usually 3-5 in Vitastor:
|
|
1. Journal block write
|
|
2. Journal data write
|
|
3. Metadata block write
|
|
4. Another journal block write for EC/XOR setups
|
|
5. Data block write
|
|
|
|
If you manage to get an SSD which handles 512 byte blocks well (Optane?) you may
|
|
lower 1, 3 and 4 to 512 bytes (1/8 of data size) and get WA as low as 2.375.
|
|
|
|
Implemented NVDIMM support can basically eliminate WA at all - all extra writes will
|
|
go to DRAM memory. But this requires a test cluster with NVDIMM - please contact me
|
|
if you want to provide me with such cluster for tests.
|
|
|
|
Lazy fsync also reduces WA for parallel workloads because journal blocks are only
|
|
written when they fill up or fsync is requested.
|
|
|
|
## In Practice
|
|
|
|
In practice, using tests from [Understanding Performance](understanding.en.md), decent TCP network,
|
|
good server-grade SSD/NVMe drives and disabled CPU power saving, you should head for:
|
|
- At least 5000 T1Q1 replicated read and write iops (maximum 0.2ms latency)
|
|
- At least 5000 T1Q1 EC read IOPS and at least 2200 EC write IOPS (maximum 0.45ms latency)
|
|
- At least ~80k parallel read iops or ~30k write iops per 1 core (1 OSD)
|
|
- Disk-speed or wire-speed linear reads and writes, whichever is the bottleneck in your case
|
|
|
|
Lower results may mean that you have bad drives, bad network or some kind of misconfiguration.
|
|
|
|
Current latency records:
|
|
- 9668 T1Q1 replicated write iops (0.103 ms latency) with TCP and NVMe
|
|
- 9143 T1Q1 replicated read iops (0.109 ms latency) with TCP and NVMe
|