# Runtime OSD Parameters
|
|
|
|
These parameters only apply to OSDs, are not fixed at the moment of OSD drive
|
|
initialization and can be changed - either with an OSD restart or, for some of
|
|
them, even without restarting by updating configuration in etcd.
|
|
|
|
- [etcd_report_interval](#etcd_report_interval)
|
|
- [etcd_stats_interval](#etcd_stats_interval)
|
|
- [run_primary](#run_primary)
|
|
- [osd_network](#osd_network)
|
|
- [bind_address](#bind_address)
|
|
- [bind_port](#bind_port)
|
|
- [autosync_interval](#autosync_interval)
|
|
- [autosync_writes](#autosync_writes)
|
|
- [recovery_queue_depth](#recovery_queue_depth)
|
|
- [recovery_pg_switch](#recovery_pg_switch)
|
|
- [recovery_sync_batch](#recovery_sync_batch)
|
|
- [readonly](#readonly)
|
|
- [no_recovery](#no_recovery)
|
|
- [no_rebalance](#no_rebalance)
|
|
- [print_stats_interval](#print_stats_interval)
|
|
- [slow_log_interval](#slow_log_interval)
|
|
- [inode_vanish_time](#inode_vanish_time)
|
|
- [max_write_iodepth](#max_write_iodepth)
|
|
- [min_flusher_count](#min_flusher_count)
|
|
- [max_flusher_count](#max_flusher_count)
|
|
- [inmemory_metadata](#inmemory_metadata)
|
|
- [inmemory_journal](#inmemory_journal)
|
|
- [data_io](#data_io)
|
|
- [meta_io](#meta_io)
|
|
- [journal_io](#journal_io)
|
|
- [journal_sector_buffer_count](#journal_sector_buffer_count)
|
|
- [journal_no_same_sector_overwrites](#journal_no_same_sector_overwrites)
|
|
- [throttle_small_writes](#throttle_small_writes)
|
|
- [throttle_target_iops](#throttle_target_iops)
|
|
- [throttle_target_mbs](#throttle_target_mbs)
|
|
- [throttle_target_parallelism](#throttle_target_parallelism)
|
|
- [throttle_threshold_us](#throttle_threshold_us)
|
|
- [osd_memlock](#osd_memlock)
|
|
- [auto_scrub](#auto_scrub)
|
|
- [no_scrub](#no_scrub)
|
|
- [scrub_interval](#scrub_interval)
|
|
- [scrub_queue_depth](#scrub_queue_depth)
|
|
- [scrub_sleep](#scrub_sleep)
|
|
- [scrub_list_limit](#scrub_list_limit)
|
|
- [scrub_find_best](#scrub_find_best)
|
|
- [scrub_ec_max_bruteforce](#scrub_ec_max_bruteforce)
|
|
|
|
## etcd_report_interval
|
|
|
|
- Type: seconds
|
|
- Default: 5
|
|
|
|
Interval at which OSDs report their liveness to etcd. Affects OSD lease time
|
|
and thus the failover speed. Lease time is equal to this parameter value
|
|
plus max_etcd_attempts * etcd_quick_timeout because it should be guaranteed
|
|
that every OSD always refreshes its lease in time.
|
|
|
|
## etcd_stats_interval
|
|
|
|
- Type: seconds
|
|
- Default: 30
|
|
|
|
Interval at which OSDs report their statistics to etcd. Highly affects the
|
|
imposed load on etcd, because statistics include a key for every OSD and
|
|
for every PG. At the same time, low statistic intervals make `vitastor-cli`
|
|
statistics more responsive.
|
|
|
|
## run_primary
|
|
|
|
- Type: boolean
|
|
- Default: true
|
|
|
|
Start primary OSD logic on this OSD. As of now, can be turned off only for
|
|
debugging purposes. It's possible to implement additional feature for the
|
|
monitor which may allow to separate primary and secondary OSDs, but it's
|
|
unclear why anyone could need it, so it's not implemented.
|
|
|
|
## osd_network
|
|
|
|
- Type: string or array of strings
|
|
|
|
Network mask of the network (IPv4 or IPv6) to use for OSDs. Note that
|
|
although it's possible to specify multiple networks here, this does not
|
|
mean that OSDs will create multiple listening sockets - they'll only
|
|
pick the first matching address of an UP + RUNNING interface. Separate
|
|
networks for cluster and client connections are also not implemented, but
|
|
they are mostly useless anyway, so it's not a big deal.
|
|
|
|
## bind_address
|
|
|
|
- Type: string
|
|
- Default: 0.0.0.0
|
|
|
|
Instead of the network mask, you can also set OSD listen address explicitly
|
|
using this parameter. May be useful if you want to start OSDs on interfaces
|
|
that are not UP + RUNNING.
|
|
|
|
## bind_port
|
|
|
|
- Type: integer
|
|
|
|
By default, OSDs pick random ports to use for incoming connections
|
|
automatically. With this option you can set a specific port for a specific
|
|
OSD by hand.
|
|
|
|
## autosync_interval
|
|
|
|
- Type: seconds
|
|
- Default: 5
|
|
- Can be changed online: yes
|
|
|
|
Time interval at which automatic fsyncs/flushes are issued by each OSD when
|
|
the immediate_commit mode if disabled. fsyncs are required because without
|
|
them OSDs quickly fill their journals, become unable to clear them and
|
|
stall. Also this option limits the amount of recent uncommitted changes
|
|
which OSDs may lose in case of a power outage in case when clients don't
|
|
issue fsyncs at all.
|
|
|
|
## autosync_writes
|
|
|
|
- Type: integer
|
|
- Default: 128
|
|
- Can be changed online: yes
|
|
|
|
Same as autosync_interval, but sets the maximum number of uncommitted write
|
|
operations before issuing an fsync operation internally.
|
|
|
|
## recovery_queue_depth
|
|
|
|
- Type: integer
|
|
- Default: 4
|
|
- Can be changed online: yes
|
|
|
|
Maximum recovery operations per one primary OSD at any given moment of time.
|
|
Currently it's the only parameter available to tune the speed or recovery
|
|
and rebalancing, but it's planned to implement more.
|
|
|
|
## recovery_pg_switch
|
|
|
|
- Type: integer
|
|
- Default: 128
|
|
- Can be changed online: yes
|
|
|
|
Number of recovery operations before switching to recovery of the next PG.
|
|
The idea is to mix all PGs during recovery for more even space and load
|
|
distribution but still benefit from recovery queue depth greater than 1.
|
|
Degraded PGs are anyway scanned first.
|
|
|
|
## recovery_sync_batch
|
|
|
|
- Type: integer
|
|
- Default: 16
|
|
- Can be changed online: yes
|
|
|
|
Maximum number of recovery operations before issuing an additional fsync.
|
|
|
|
## readonly
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
|
|
Read-only mode. If this is enabled, an OSD will never issue any writes to
|
|
the underlying device. This may be useful for recovery purposes.
|
|
|
|
## no_recovery
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
- Can be changed online: yes
|
|
|
|
Disable automatic background recovery of objects. Note that it doesn't
|
|
affect implicit recovery of objects happening during writes - a write is
|
|
always made to a full set of at least pg_minsize OSDs.
|
|
|
|
## no_rebalance
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
- Can be changed online: yes
|
|
|
|
Disable background movement of data between different OSDs. Disabling it
|
|
means that PGs in the `has_misplaced` state will be left in it indefinitely.
|
|
|
|
## print_stats_interval
|
|
|
|
- Type: seconds
|
|
- Default: 3
|
|
- Can be changed online: yes
|
|
|
|
Time interval at which OSDs print simple human-readable operation
|
|
statistics on stdout.
|
|
|
|
## slow_log_interval
|
|
|
|
- Type: seconds
|
|
- Default: 10
|
|
- Can be changed online: yes
|
|
|
|
Time interval at which OSDs dump slow or stuck operations on stdout, if
|
|
they're any. Also it's the time after which an operation is considered
|
|
"slow".
|
|
|
|
## inode_vanish_time
|
|
|
|
- Type: seconds
|
|
- Default: 60
|
|
- Can be changed online: yes
|
|
|
|
Number of seconds after which a deleted inode is removed from OSD statistics.
|
|
|
|
## max_write_iodepth
|
|
|
|
- Type: integer
|
|
- Default: 128
|
|
- Can be changed online: yes
|
|
|
|
Parallel client write operation limit per one OSD. Operations that exceed
|
|
this limit are pushed to a temporary queue instead of being executed
|
|
immediately.
|
|
|
|
## min_flusher_count
|
|
|
|
- Type: integer
|
|
- Default: 1
|
|
- Can be changed online: yes
|
|
|
|
Flusher is a micro-thread that moves data from the journal to the data
|
|
area of the device. Their number is auto-tuned between minimum and maximum.
|
|
Minimum number is set by this parameter.
|
|
|
|
## max_flusher_count
|
|
|
|
- Type: integer
|
|
- Default: 256
|
|
- Can be changed online: yes
|
|
|
|
Maximum number of journal flushers (see above min_flusher_count).
|
|
|
|
## inmemory_metadata
|
|
|
|
- Type: boolean
|
|
- Default: true
|
|
|
|
This parameter makes Vitastor always keep metadata area of the block device
|
|
in memory. It's required for good performance because it allows to avoid
|
|
additional read-modify-write cycles during metadata modifications. Metadata
|
|
area size is currently roughly 224 MB per 1 TB of data. You can turn it off
|
|
to reduce memory usage by this value, but it will hurt performance. This
|
|
restriction is likely to be removed in the future along with the upgrade
|
|
of the metadata storage scheme.
|
|
|
|
## inmemory_journal
|
|
|
|
- Type: boolean
|
|
- Default: true
|
|
|
|
This parameter make Vitastor always keep journal area of the block
|
|
device in memory. Turning it off will, again, reduce memory usage, but
|
|
hurt performance because flusher coroutines will have to read data from
|
|
the disk back before copying it into the main area. The memory usage benefit
|
|
is typically very small because it's sufficient to have 16-32 MB journal
|
|
for SSD OSDs. However, in theory it's possible that you'll want to turn it
|
|
off for hybrid (HDD+SSD) OSDs with large journals on quick devices.
|
|
|
|
## data_io
|
|
|
|
- Type: string
|
|
- Default: direct
|
|
|
|
I/O mode for *data*. One of "direct", "cached" or "directsync". Corresponds
|
|
to O_DIRECT, O_SYNC and O_DIRECT|O_SYNC, respectively.
|
|
|
|
Choose "cached" to use Linux page cache. This may improve read performance
|
|
for hot data and slower disks - HDDs and maybe SATA SSDs - but will slightly
|
|
decrease write performance for fast disks because page cache is an overhead
|
|
itself.
|
|
|
|
Choose "directsync" to use [immediate_commit](layout-cluster.ru.md#immediate_commit)
|
|
(which requires disable_data_fsync) with drives having write-back cache
|
|
which can't be turned off, for example, Intel Optane. Also note that *some*
|
|
desktop SSDs (for example, HP EX950) may ignore O_SYNC thus making
|
|
disable_data_fsync unsafe even with "directsync".
|
|
|
|
## meta_io
|
|
|
|
- Type: string
|
|
- Default: direct
|
|
|
|
I/O mode for *metadata*. One of "direct", "cached" or "directsync".
|
|
|
|
"cached" may improve read performance, but only under the following conditions:
|
|
1. your drives are relatively slow (HDD, SATA SSD), and
|
|
2. checksums are enabled, and
|
|
3. [inmemory_metadata](#inmemory_metadata) is disabled.
|
|
Under all these conditions, metadata blocks are read from disk on every
|
|
read request to verify checksums and caching them may reduce this extra
|
|
read load. Without (3) metadata is never read from the disk after starting,
|
|
and without (2) metadata blocks are read from disk only during journal
|
|
flushing.
|
|
|
|
"directsync" is the same as above.
|
|
|
|
If the same device is used for data and metadata, meta_io by default is set
|
|
to the same value as [data_io](#data_io).
|
|
|
|
## journal_io
|
|
|
|
- Type: string
|
|
- Default: direct
|
|
|
|
I/O mode for *journal*. One of "direct", "cached" or "directsync".
|
|
|
|
Here, "cached" may only improve read performance for recent writes and
|
|
only if [inmemory_journal](#inmemory_journal) is turned off.
|
|
|
|
If the same device is used for metadata and journal, journal_io by default
|
|
is set to the same value as [meta_io](#meta_io).
|
|
|
|
## journal_sector_buffer_count
|
|
|
|
- Type: integer
|
|
- Default: 32
|
|
|
|
Maximum number of buffers that can be used for writing journal metadata
|
|
blocks. The only situation when you should increase it to a larger value
|
|
is when you enable journal_no_same_sector_overwrites. In this case set
|
|
it to, for example, 1024.
|
|
|
|
## journal_no_same_sector_overwrites
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
|
|
Enable this option for SSDs like Intel D3-S4510 and D3-S4610 which REALLY
|
|
don't like when a program overwrites the same sector multiple times in a
|
|
row and slow down significantly (from 25000+ iops to ~3000 iops). When
|
|
this option is set, Vitastor will always move to the next sector of the
|
|
journal after writing it instead of possibly overwriting it the second time.
|
|
|
|
Most (99%) other SSDs don't need this option.
|
|
|
|
## throttle_small_writes
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
- Can be changed online: yes
|
|
|
|
Enable soft throttling of small journaled writes. Useful for hybrid OSDs
|
|
with fast journal/metadata devices and slow data devices. The idea is that
|
|
small writes complete very quickly because they're first written to the
|
|
journal device, but moving them to the main device is slow. So if an OSD
|
|
allows clients to issue a lot of small writes it will perform very good
|
|
for several seconds and then the journal will fill up and the performance
|
|
will drop to almost zero. Throttling is meant to prevent this problem by
|
|
artifically slowing quick writes down based on the amount of free space in
|
|
the journal. When throttling is used, the performance of small writes will
|
|
decrease smoothly instead of abrupt drop at the moment when the journal
|
|
fills up.
|
|
|
|
## throttle_target_iops
|
|
|
|
- Type: integer
|
|
- Default: 100
|
|
- Can be changed online: yes
|
|
|
|
Target maximum number of throttled operations per second under the condition
|
|
of full journal. Set it to approximate random write iops of your data devices
|
|
(HDDs).
|
|
|
|
## throttle_target_mbs
|
|
|
|
- Type: integer
|
|
- Default: 100
|
|
- Can be changed online: yes
|
|
|
|
Target maximum bandwidth in MB/s of throttled operations per second under
|
|
the condition of full journal. Set it to approximate linear write
|
|
performance of your data devices (HDDs).
|
|
|
|
## throttle_target_parallelism
|
|
|
|
- Type: integer
|
|
- Default: 1
|
|
- Can be changed online: yes
|
|
|
|
Target maximum parallelism of throttled operations under the condition of
|
|
full journal. Set it to approximate internal parallelism of your data
|
|
devices (1 for HDDs, 4-8 for SSDs).
|
|
|
|
## throttle_threshold_us
|
|
|
|
- Type: microseconds
|
|
- Default: 50
|
|
- Can be changed online: yes
|
|
|
|
Minimal computed delay to be applied to throttled operations. Usually
|
|
doesn't need to be changed.
|
|
|
|
## osd_memlock
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
|
|
Lock all OSD memory to prevent it from being unloaded into swap with
|
|
mlockall(). Requires sufficient ulimit -l (max locked memory).
|
|
|
|
## auto_scrub
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
- Can be changed online: yes
|
|
|
|
Data scrubbing is the process of background verification of copies to find
|
|
and repair corrupted blocks. It's not run automatically by default since
|
|
it's a new feature. Set this parameter to true to enable automatic scrubs.
|
|
|
|
This parameter makes OSDs automatically schedule data scrubbing of clean PGs
|
|
every `scrub_interval` (see below). You can also start/schedule scrubbing
|
|
manually by setting `next_scrub` JSON key to the desired UNIX time of the
|
|
next scrub in `/pg/history/...` values in etcd.
|
|
|
|
## no_scrub
|
|
|
|
- Type: boolean
|
|
- Default: false
|
|
- Can be changed online: yes
|
|
|
|
Temporarily disable scrubbing and stop running scrubs.
|
|
|
|
## scrub_interval
|
|
|
|
- Type: string
|
|
- Default: 30d
|
|
- Can be changed online: yes
|
|
|
|
Default automatic scrubbing interval for all pools. Numbers without suffix
|
|
are treated as seconds, possible unit suffixes include 's' (seconds),
|
|
'm' (minutes), 'h' (hours), 'd' (days), 'M' (months) and 'y' (years).
|
|
|
|
## scrub_queue_depth
|
|
|
|
- Type: integer
|
|
- Default: 1
|
|
- Can be changed online: yes
|
|
|
|
Number of parallel scrubbing operations per one OSD.
|
|
|
|
## scrub_sleep
|
|
|
|
- Type: milliseconds
|
|
- Default: 0
|
|
- Can be changed online: yes
|
|
|
|
Additional interval between two consecutive scrubbing operations on one OSD.
|
|
Can be used to slow down scrubbing if it affects user load too much.
|
|
|
|
## scrub_list_limit
|
|
|
|
- Type: integer
|
|
- Default: 1000
|
|
- Can be changed online: yes
|
|
|
|
Number of objects to list in one listing operation during scrub.
|
|
|
|
## scrub_find_best
|
|
|
|
- Type: boolean
|
|
- Default: true
|
|
- Can be changed online: yes
|
|
|
|
Find and automatically restore best versions of objects with unmatched
|
|
copies. In replicated setups, the best version is the version with most
|
|
matching replicas. In EC setups, the best version is the subset of data
|
|
and parity chunks without mismatches.
|
|
|
|
The hypothetical situation where you might want to disable it is when
|
|
you have 3 replicas and you are paranoid that 2 HDDs out of 3 may silently
|
|
corrupt an object in the same way (for example, zero it out) and only
|
|
1 HDD will remain good. In this case disabling scrub_find_best may help
|
|
you to recover the data! See also scrub_ec_max_bruteforce below.
|
|
|
|
## scrub_ec_max_bruteforce
|
|
|
|
- Type: integer
|
|
- Default: 100
|
|
- Can be changed online: yes
|
|
|
|
Vitastor can locate corrupted chunks in EC setups with more than 1 parity
|
|
chunk by brute-forcing all possible error locations. This configuration
|
|
value limits the maximum number of checked combinations. You can try to
|
|
increase it if you have EC N+K setup with N and K large enough for
|
|
combination count `C(N+K-1, K-1) = (N+K-1)! / (K-1)! / N!` to be greater
|
|
than the default 100.
|
|
|
|
If there are too many possible combinations or if multiple combinations give
|
|
correct results then objects are marked inconsistent and aren't recovered
|
|
automatically.
|
|
|
|
In replicated setups bruteforcing isn't needed, Vitastor just assumes that
|
|
the variant with most available equal copies is correct. For example, if
|
|
you have 3 replicas and 1 of them differs, this one is considered to be
|
|
corrupted. But if there is no "best" version with more copies than all
|
|
others have then the object is also marked as inconsistent.
|