# Cluster-Wide Disk Layout Parameters
|
|
|
|
These parameters apply to clients and OSDs, are fixed at the moment of OSD drive
|
|
initialization and can't be changed after it without losing data.
|
|
|
|
- [block_size](#block_size)
|
|
- [bitmap_granularity](#bitmap_granularity)
|
|
- [immediate_commit](#immediate_commit)
|
|
- [client_dirty_limit](#client_dirty_limit)
|
|
|
|
## block_size
|
|
|
|
- Type: integer
|
|
- Default: 131072
|
|
|
|
Size of objects (data blocks) into which all physical and virtual drives are
|
|
subdivided in Vitastor. One of current main settings in Vitastor, affects
|
|
memory usage, write amplification and I/O load distribution effectiveness.
|
|
|
|
Recommended default block size is 128 KB for SSD and 4 MB for HDD. In fact,
|
|
it's possible to use 4 MB for SSD too - it will lower memory usage, but
|
|
may increase average WA and reduce linear performance.
|
|
|
|
OSDs with different block sizes (for example, SSD and SSD+HDD OSDs) can
|
|
currently coexist in one etcd instance only within separate Vitastor
|
|
clusters with different etcd_prefix'es.
|
|
|
|
Also block size can't be changed after OSD initialization without losing
|
|
data.
|
|
|
|
You must always specify block_size in etcd in /vitastor/config/global if
|
|
you change it so all clients can know about it.
|
|
|
|
OSD memory usage is roughly (SIZE / BLOCK * 68 bytes) which is roughly
|
|
544 MB per 1 TB of used disk space with the default 128 KB block size.
|
|
|
|
## bitmap_granularity
|
|
|
|
- Type: integer
|
|
- Default: 4096
|
|
|
|
Required virtual disk write alignment ("sector size"). Must be a multiple
|
|
of disk_alignment. It's called bitmap granularity because Vitastor tracks
|
|
an allocation bitmap for each object containing 2 bits per each
|
|
(bitmap_granularity) bytes.
|
|
|
|
This parameter can't be changed after OSD initialization without losing
|
|
data. Also it's fixed for the whole Vitastor cluster i.e. two different
|
|
values can't be used in a single Vitastor cluster.
|
|
|
|
Clients MUST be aware of this parameter value, so put it into etcd key
|
|
/vitastor/config/global if you change it for any reason.
|
|
|
|
## immediate_commit
|
|
|
|
- Type: string
|
|
- Default: false
|
|
|
|
Another parameter which is really important for performance.
|
|
|
|
Desktop SSDs are very fast (100000+ iops) for simple random writes
|
|
without cache flush. However, they are really slow (only around 1000 iops)
|
|
if you try to fsync() each write, that is, when you want to guarantee that
|
|
each change gets immediately persisted to the physical media.
|
|
|
|
Server-grade SSDs with "Advanced/Enhanced Power Loss Protection" or with
|
|
"Supercapacitor-based Power Loss Protection", on the other hand, are equally
|
|
fast with and without fsync because their cache is protected from sudden
|
|
power loss by a built-in supercapacitor-based "UPS".
|
|
|
|
Some software-defined storage systems always fsync each write and thus are
|
|
really slow when used with desktop SSDs. Vitastor, however, can also
|
|
efficiently utilize desktop SSDs by postponing fsync until the client calls
|
|
it explicitly.
|
|
|
|
This is what this parameter regulates. When it's set to "all" the whole
|
|
Vitastor cluster commits each change to disks immediately and clients just
|
|
ignore fsyncs because they know for sure that they're unneeded. This reduces
|
|
the amount of network roundtrips performed by clients and improves
|
|
performance. So it's always better to use server grade SSDs with
|
|
supercapacitors even with Vitastor, especially given that they cost only
|
|
a bit more than desktop models.
|
|
|
|
There is also a common SATA SSD (and HDD too!) firmware bug (or feature)
|
|
that makes server SSDs which have supercapacitors slow with fsync. To check
|
|
if your SSDs are affected, compare benchmark results from `fio -name=test
|
|
-ioengine=libaio -direct=1 -bs=4k -rw=randwrite -iodepth=1` with and without
|
|
`-fsync=1`. Results should be the same. If fsync=1 result is worse you can
|
|
try to work around this bug by "disabling" drive write-back cache by running
|
|
`hdparm -W 0 /dev/sdXX` or `echo write through > /sys/block/sdXX/device/scsi_disk/*/cache_type`
|
|
(IMPORTANT: don't mistake it with `/sys/block/sdXX/queue/write_cache` - it's
|
|
unsafe to change by hand). The same may apply to newer HDDs with internal
|
|
SSD cache or "media-cache" - for example, a lot of Seagate EXOS drives have
|
|
it (they have internal SSD cache even though it's not stated in datasheets).
|
|
|
|
This parameter must be set both in etcd in /vitastor/config/global and in
|
|
OSD command line or configuration. Setting it to "all" or "small" requires
|
|
enabling disable_journal_fsync and disable_meta_fsync, setting it to "all"
|
|
also requires enabling disable_data_fsync.
|
|
|
|
TLDR: For optimal performance, set immediate_commit to "all" if you only use
|
|
SSDs with supercapacitor-based power loss protection (nonvolatile
|
|
write-through cache) for both data and journals in the whole Vitastor
|
|
cluster. Set it to "small" if you only use such SSDs for journals. Leave
|
|
empty if your drives have write-back cache.
|
|
|
|
## client_dirty_limit
|
|
|
|
- Type: integer
|
|
- Default: 33554432
|
|
|
|
Without immediate_commit=all this parameter sets the limit of "dirty"
|
|
(not committed by fsync) data allowed by the client before forcing an
|
|
additional fsync and committing the data. Also note that the client always
|
|
holds a copy of uncommitted data in memory so this setting also affects
|
|
RAM usage of clients.
|
|
|
|
This parameter doesn't affect OSDs themselves.
|